Update NeurIPS 2026 submission a6hNtJbbEt: 6 notes
@openreview[bot] · 2026-11-24 15:52 UTC · f4e3072c5b97 ·
reviews/openreview/a6hntjbbet/notes/dhesptbk6o.json added
+++ b/reviews/openreview/a6hntjbbet/notes/dhesptbk6o.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Dhesptbk6o",+ "replyTo": "xGUYLNrCni",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Clarifications of Reviewer Misunderstandings and Responses to Issues and Weaknesses",+ "comment": "We thank your careful comments. We first **clarify the factual misunderstanding from Reviewer xdwB**. Appendix Fig. 5 already explicitly reports the test sizes: ReX 147/90/60, LIDC 132/133/60, and Abdomen 86/104/50 for Stat./Sel./Gen. Therefore, the reverse-engineered counts are incorrect, and ReX Stat. has 147 rather than about 49 cases. More importantly, EasyLens is an inference-time enhancement module rather than a standalone medical VLM, **so the key comparison is the same frozen backbone with and without EasyLens**. On ReX, MedGemma1.5 improves from 63/147 to 98/147 on Stat. (+35) and from 21/90 to 28/90 on Sel. (+7). More detailed experiments are provided in our response to Issue 1. \n\n---\n\n(Abbreviations: MG=MedGemma1.5, EL=EasyLens, HM=Hulu-Med, DCI=Delta 95% CI. `*` p<0.05, `**` p<0.01, `***` p<0.005.)\n\n**[Issue 1, W1]**: Performance, significance test and multi-seed experiments\n\n**Response**: We conduct paired confidence-interval and significance analyses, together with 10-run stability experiments, for MG and HM. Tables 1–2 show statistically significant gains across all nine tasks. In terms of additional correct cases for Stat./Sel./Gen., MG improves on ReX (+35/+7/+6), LIDC (+13/+11/+8), and Abdomen (+32/+7/+7), while HM improves on ReX (+20/+9/+8), LIDC (+12/+11/+7), and Abdomen (+16/+12/+9). The repeated-run results further confirm the stability of these improvements in different seed settings. (Gen. is evaluated using the new metric.)\n\n**Table 1**. Performance, paired CI, and significance.\n\n|Task|N|MG|EL(MG)|DCI|p|HM|EL(HM)|DCI|p|\n|-|-|-|-|-|-|-|-|-|-|\n|ReX Stat.|147|42.86|66.67|+23.81[+16.33,+31.97]|`***`|64.63|78.23|+13.61[+6.12,+21.09]|`***`|\n|ReX Sel.|90|23.33|31.11|+7.78[+2.22,+13.33]|`*`|27.78|37.78|+10.00[+4.44,+16.67]|`***`|\n|ReX Gen.|60|6.67|16.67|+10.00[3.33,18.33]|`*`|5.00|18.33|+13.33[5.00,21.67]|`**`|\n|LIDC Stat.|132|20.45|30.30|+9.85[+3.03,+16.67]|`**`|28.79|37.88|+9.09[+3.79,+14.39]|`***`|\n|LIDC Sel.|133|27.82|36.09|+8.27[+3.76,+13.53]|`***`|30.83|39.10|+8.27[+3.76,+13.53]|`***`|\n|LIDC Gen.|60|13.33|26.67|+13.33[5.00,21.67]|`*`|8.33|20.00|+11.67[+5.00,+20.00]|`*`|\n|Abd. Stat.|86|15.12|52.33|+37.21[+26.74,+47.67]|`***`|51.16|69.77|+18.60[+9.30,+27.91]|`***`|\n|Abd. Sel.|104|49.04|55.77|+6.73[+1.92,+11.54]|`*`|52.88|64.42|+11.54[+4.81,+18.27]|`***`|\n|Abd. Gen.|50|18.00|32.00|+14.00[+6.00,+24.00]|`*`|14.00|32.00|+18.00[+8.00,+30.00]|`*`|\n\n**Table 2**. Multi-seed stability.\n\n|Task|Rep|MG(temp)|EL(temp)|EL(kmeans)|\n|-|-|-|-|-|\n|ReX Stat.|10|42.65±5.68|66.26±7.05|61.43±10.76|\n|ReX Sel.|10|23.22±2.98|33.33±1.57|28.11±1.49|\n|ReX Gen.|10|6.50±2.66|15.67±2.96|12.33±2.96|\n|LIDC Stat.|10|20.15±3.14|30.23±2.33|28.03±1.64|\n|LIDC Sel.|10|27.52±2.30|36.09±2.63|32.33±1.46|\n|LIDC Gen.|10|14.83±2.42|25.33±2.81|22.00±2.81|\n|Abd. Stat.|10|24.07±4.78|52.33±4.07|51.63±1.83|\n|Abd. Sel.|10|41.44±2.58|55.77±3.36|55.10±0.65|\n|Abd. Gen.|10|18.40±2.46|32.20±3.19|30.00±4.11|\n\n---\n\n**[Issue 2, W2]**: Gen. metrics redesign.\n\n**Response**: We design a new lesion-description accuracy metric for Gen. using GPT-5.6 as the evaluator, which directly checks whether the generated report contains the ground-truth subtle-lesion finding. Furthermore, we would like to clarify the motivation for our original lesion-token probability metric. It was designed to assess whether the enhanced subtle-lesion representations translate during decoding into increased probabilities for the corresponding lesion terms.\n\n**Table 3**. Pathology detection accuracy for generation.\n\n|Model|ReX Gen.|LIDC Gen.|Abd. Gen.|\n|-|-|-|-|\n|MG|6.67|13.33|18.00|\n|EL(MG)|16.67|26.67|32.00|\n|HM|5.00|8.33|14.00|\n|EL(HM)|18.33|20.00|32.00|\n\n---\n\n**[Issue 3, W4]**: Data leakage clarify.\n\n**Response**: Training/validation/test splits are fully disjoint. Training constructs EasyBank; validation selects interface parameters by grid search using the same task formats as the test split; the fixed configuration is then evaluated on held-out test data. No test sample is used for prototype construction or calibration.\n\n**[W3]**: SFT and GPT comparision.\n\n**Response**: We fine-tune the same MG backbone and report GPT-5.6.\n\n**Table 4**. Comparison with SFT and GPT-5.6.\n\n|Model|ReX Stat.|ReX Sel.|ReX Gen.|LIDC Stat.|LIDC Sel.|LIDC Gen.|Abd. Stat.|Abd. Sel.|Abd. Gen.|\n|-|-|-|-|-|-|-|-|-|-|\n|EL(MG)|66.67|31.11|16.67|30.30|36.09|26.67|52.33|55.77|32.00|\n|MG-SFT|69.39|27.78|13.33|31.82|30.83|21.67|48.83|50.96|24.00|\n|GPT-5.6|70.75|20.00|18.33|38.64|27.82|23.33|37.21|49.04|38.00|\n\n---\n\n**[W5]**: False-positive experiments.\n\n**Response**: To examine false-positive behavior, we evaluate the ReX-based EasyLens on MIMIC-CXR, Kvasir-SEG, and BKAI-Polyp report-generation tasks and measure the false-positive rate. The results are shown in Table 5 and show that EasyLens does not noticeably increase false-positive lesion descriptions.\n\n**Table 5**. False-positive analysis.\n\n|Metric|MIMIC-CXR|Kvasir-SEG|BKAI-Polyp|\n|-|-|-|-|\n|False-positive rate|0.12%|0%|0%|"+ },+ "createdAt": "2026-07-28T19:12:33.768Z",+ "modifiedAt": "2026-11-19T16:57:50.070Z",+ "url": "https://openreview.net/forum?id=a6hNtJbbEt¬eId=Dhesptbk6o",+ "license": "CC-BY-4.0"+}
reviews/openreview/a6hntjbbet/notes/hbhjd0mqtx.json added
+++ b/reviews/openreview/a6hntjbbet/notes/hbhjd0mqtx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "hBHJD0MqtX",+ "replyTo": "puiScVJSvH",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer uq6G,\n\nWe understand that you may have a busy schedule, and we sincerely appreciate the time you have devoted to reviewing our submission and rebuttal.\n\nAs the author–reviewer discussion period is approaching its close, we wanted to follow up and ask whether our response has addressed your concerns. If so, we would be grateful if you could reconsider your evaluation accordingly.\n\nShould any concerns remain, or if further clarification would be helpful, we would be happy to respond.\n\nThank you again for your time and consideration.\n\nKind regards,\n\nThe Authors"+ },+ "createdAt": "2026-08-02T14:03:22.139Z",+ "modifiedAt": "2026-11-19T16:57:50.057Z",+ "url": "https://openreview.net/forum?id=a6hNtJbbEt¬eId=hBHJD0MqtX",+ "license": "CC-BY-4.0"+}
reviews/openreview/a6hntjbbet/notes/ihqhjgkegh.json added
+++ b/reviews/openreview/a6hntjbbet/notes/ihqhjgkegh.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "IHqHJGkeGh",+ "replyTo": "xGUYLNrCni",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Area Chair 4wHn,\n\nWe understand that the concerns regarding the meaningfulness and reliability of our performance improvements may have been influenced by Reviewer xdwB’s assessment. After we clarified the misunderstandings and provided additional experimental evidence, Reviewer xdwB reconsidered our rebuttal and raised the score from 3 to 4. We therefore respectfully ask that you reassess the meaningfulness of our performance gains and the confidence supported by the updated evidence.\n\nWe understand that you may have a busy schedule, and we sincerely appreciate the time you have devoted to reviewing our submission and rebuttal.\n\nAs the author–reviewer discussion period is approaching its close, we wanted to follow up and ask whether our response has addressed your concerns. If so, we would be grateful if you could reconsider your evaluation accordingly.\n\nShould any concerns remain, or if further clarification would be helpful, we would be happy to respond.\n\nThank you again for your time and consideration.\n\nKind regards,\n\nThe Authors",+ "title": "Follow-up on Performance Concerns and Updated Reviewer Assessment"+ },+ "createdAt": "2026-08-02T14:01:10.672Z",+ "modifiedAt": "2026-11-19T16:57:50.070Z",+ "url": "https://openreview.net/forum?id=a6hNtJbbEt¬eId=IHqHJGkeGh",+ "license": "CC-BY-4.0"+}
reviews/openreview/a6hntjbbet/notes/lp6sicxy6h.json added
+++ b/reviews/openreview/a6hntjbbet/notes/lp6sicxy6h.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "LP6SIcxy6H",+ "replyTo": "Rtjgxc0JoB",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer xdwB,\n\nThank you very much for reconsidering our response and raising your score. We sincerely appreciate your time and thoughtful evaluation.\n\nIf any concerns remain, we would be very happy to discuss them and provide further clarification.\n\nKind regards,\n\nThe Authors"+ },+ "createdAt": "2026-08-02T14:02:14.607Z",+ "modifiedAt": "2026-11-19T16:57:50.259Z",+ "url": "https://openreview.net/forum?id=a6hNtJbbEt¬eId=LP6SIcxy6H",+ "license": "CC-BY-4.0"+}
reviews/openreview/a6hntjbbet/notes/v9sygb0xdh.json added
+++ b/reviews/openreview/a6hntjbbet/notes/v9sygb0xdh.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "v9SyGB0XdH",+ "replyTo": "DbQ4iN4INe",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer wdZN,\n\nWe understand that you may have a busy schedule, and we sincerely appreciate the time you have devoted to reviewing our submission and rebuttal.\n\nAs the author–reviewer discussion period is approaching its close, we wanted to follow up and ask whether our response has addressed your concerns. If so, we would be grateful if you could reconsider your evaluation accordingly.\n\nShould any concerns remain, or if further clarification would be helpful, we would be happy to respond.\n\nThank you again for your time and consideration.\n\nKind regards,\n\nThe Authors"+ },+ "createdAt": "2026-08-02T14:02:43.971Z",+ "modifiedAt": "2026-11-19T16:57:50.261Z",+ "url": "https://openreview.net/forum?id=a6hNtJbbEt¬eId=v9SyGB0XdH",+ "license": "CC-BY-4.0"+}
reviews/openreview/a6hntjbbet/notes/xguylnrcni.json modified
+++ b/reviews/openreview/a6hntjbbet/notes/xguylnrcni.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 4wHn","content": {- "metareview": "The paper proposes a training-free, plug-and-play inference-time module for frozen medical VLMs. The system contains three part: easybank, easytag, and easyemplifier. The paper reports improvements in subtle lesion performance. Evaluation on a constructed subtle-lesion benchmark from ReXGroundingCT, LIDC-IDRI, and AbdomenAtlas shows the performance gains. \n\n\nStrengths:\n1. The problem is clear, and the motivation for the failure mode is scientifically meaningful. \n2. The proposed method of training free models is technically sound. \n3. The paper includes an ablation study. \n\nWeaknesses:\n1. The test set size is not included in the paper. The experiment results are not very meaningful. For example, given ~49 cases for ReX Stat., ~90 for ReX Sel, the claimed 2.04-point lead on ReX Stat is literally one case (1/49 = 2.04%), and the 3.33-point Sel. lead is three cases.\n2. The generation metrics, such as the subtle-lesion Gen, did not guarantee final output. Such internal signals did not evaluate the actual generated output paper. \n3. Some baselines are missing, including small backbone finetuned models for subtle-lesion detection on the same labeled data. \n4. Some paper details are missing, like Interface calibration, data-split constructions, and potential leakage.\n5. False-positive behavior is underexplored. \n\nIssues that could materially change the recommendation.\n1. Present the test set statistics, run experiments on multiple seeds, and also provide significance tests for the improvement. \n2. Use other generated results to directly provide output-level-based evaluation to verify the effectiveness of subtle-lesion Gen. \n3. Check whether there is any data leakage."+ "metareview": "The paper proposes a training-free, plug-and-play inference-time module for frozen medical VLMs. The system contains three part: easybank, easytag, and easyemplifier. The paper reports improvements in subtle lesion performance. Evaluation on a constructed subtle-lesion benchmark from ReXGroundingCT, LIDC-IDRI, and AbdomenAtlas shows the performance gains. \n\n\nStrengths:\n1. The problem is clear, and the motivation for the failure mode is scientifically meaningful. \n2. The proposed method of training free models is technically sound. \n3. The paper includes an ablation study. \n\nWeaknesses:\n1. The test set size is not included in the paper. The experiment results are not very meaningful. For example, given ~49 cases for ReX Stat., ~90 for ReX Sel, the claimed 2.04-point lead on ReX Stat is literally one case (1/49 = 2.04%), and the 3.33-point Sel. lead is three cases.\n2. The generation metrics, such as the subtle-lesion Gen, did not guarantee final output. Such internal signals did not evaluate the actual generated output paper. \n3. Some baselines are missing, including small backbone finetuned models for subtle-lesion detection on the same labeled data. \n4. Some paper details are missing, like Interface calibration, data-split constructions, and potential leakage.\n5. False-positive behavior is underexplored. \n\nIssues that could materially change the recommendation.\n1. Present the test set statistics, run experiments on multiple seeds, and also provide significance tests for the improvement. \n2. Use other generated results to directly provide output-level-based evaluation to verify the effectiveness of subtle-lesion Gen. \n3. Check whether there is any data leakage.",+ "final_justification": "I have read the author's rebuttal and discussion with reviewers. Reviewer xdwB raised the score to 4 after reconsidering the additional evidence. Reviewers wdZN and uq6G maintained borderline-accept scores while identifying remaining limitations rather than fundamental correctness issues.\n\nIssues in my metareview have been fully addressed.\n\nOverall, reviewers are leaning towards positive."},"createdAt": "2026-07-23T08:18:36.443Z",- "modifiedAt": "2026-11-18T15:19:19.428Z",+ "modifiedAt": "2026-11-19T04:59:36.261Z","url": "https://openreview.net/forum?id=a6hNtJbbEt¬eId=xGUYLNrCni","license": "CC-BY-4.0"}