Import NeurIPS 2026 submission Q5Hpa44zeJ: 10 notes
@openreview[bot] · 2026-11-22 17:56 UTC · 1a03f902a091
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,22 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "Q5Hpa44zeJ"+ }+ ],+ "title": "Can Metadata Fix the Gauge? Calibration Turns Sparse Multi-Source Learning from Sparse PCA into Sparse Mean Recovery",+ "authors": [+ "Yirong Xiang",+ "Yibo Zhou"+ ],+ "abstract": "Source labels tell us where a sample came from, but not how that source oriented its coordinates. In a sparse Gaussian multi-source model with source-specific sign gauges, that distinction changes the learning problem. Without calibration, pooling across sources erases the mean signal, and the source-labelled experiment reduces to sparse PCA. With task-independent relative-gauge metadata, synchronization aligns sources and the same observations become a sparse mean problem. We formalize the value of metadata through AlignedMass, which quantifies how much first-order signal a metadata-induced alignment restores. Source labels create only limited AlignedMass, whereas valid calibration can create AlignedMass proportional to the full sample size. This yields a statistical separation in micro-source regimes and, under standard sparse-PCA hardness assumptions, a computational separation as well. Synthetic experiments check the predicted scaling; controlled real-feature and physical sensor studies examine sign cancellation, separately acquired calibration, and reuse across tasks.",+ "year": 2026,+ "venue": "NeurIPS 2026",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/q5hpa44zej/forms.json added
+++ b/reviews/openreview/q5hpa44zej/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/q5hpa44zej/notes/93h9lzqcek.json added
+++ b/reviews/openreview/q5hpa44zej/notes/93h9lzqcek.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "93h9lZQCEk",+ "replyTo": "vwVXciph4l",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for the detailed and balanced review. We agree with your central point: spectral synchronization, weighted averaging, and top-$k$ thresholding are standard. We will make clear that the contribution is statistical rather than algorithmic.\n\n> **(1) Statistical novelty**\n\nThere are $L$ sources with $s$ observations each, so $n=Ls$. Under the i.i.d. Rademacher-gauge model, $W_{\\ell r}=\\theta R_\\ell\\sigma_\\ell V+\\varepsilon_{\\ell r}$, where $R_\\ell\\sigma_\\ell\\sim N(0,1)$ and $\\varepsilon_{\\ell r}\\sim N(0,I_d)$. The source aggregate $X_\\ell=s^{-1/2}\\sum_r W_{\\ell r}$ satisfies $X_\\ell\\sim N(0,I_d+\\lambda VV^\\top)$ with $\\lambda=\\theta^2s$, while every source-orthogonal residual is Gaussian noise independent of $V$. **Hence the complete source-labelled uncalibrated experiment, not merely one baseline statistic, is statistically equivalent to sparse PCA plus noise independent of the task direction.** External calibration instead gives $X_q=\\theta A_qV+Z$, where $A_q=\\sum_{\\ell,r}q_{\\ell r}R_\\ell\\sigma_\\ell/\\lVert q\\rVert_2$ and $Z\\sim N(0,I_d)$, producing a sparse-mean observation up to a global sign. Aligned mass is $M_q(g)=(q^\\top g)^2/\\lVert q\\rVert_2^2$. For equal source sizes, define $\\Gamma(\\mathfrak{M},E)=\\mathbb{E}[\\sigma\\sigma^\\top\\mid\\mathfrak{M},E]$; the largest posterior expected aligned mass is then $\\mathcal{C}(\\mathfrak{M},E)=s\\lambda_{\\max}(\\Gamma(\\mathfrak{M},E))$. Under independent Rademacher signs, source labels give $\\mathcal{C}=s$, while perfect calibration gives $\\mathcal{C}=n$. Your comment points to the central novelty question: does calibration merely improve an estimator, or does it change the available statistical experiment? Our result establishes the latter.\n\n> **(2) Concrete metadata**\n\n**The physical study provides a concrete acquisition mechanism: a separately recorded reference motion reveals relative sensor orientation without using the downstream task.** We use **24 fixed device-mounting sources**, each with **10 calibration trials**. The ten time-normalized traces are aggregated into one reference trace per source, and pairwise correlation signs form a complete graph of $\\binom{24}{2}=276$ noisy same/opposite-orientation records. This graph contains no downstream labels, recordings, or task-derived features and is synchronized once before being reused across all four tasks. The downstream dataset contains $24\\times4\\times2\\times20=3{,}840$ complete trials, split **12/4/4 within each source-task-class before window extraction**. Recorded mounting signs are used only for evaluation and the oracle baseline. **Relative calibration obtains macro balanced test accuracy $0.902\\pm0.006$, compared with $0.921\\pm0.004$ for oracle polarity, $0.558\\pm0.011$ without calibration, and $0.553\\pm0.012$ with shuffled metadata. Reusing the same alignment gives per-task accuracies $0.928$, $0.905$, $0.892$, and $0.883$.**\n\n> **(3) Non-isotropic noise**\n\nIf $\\varepsilon_{\\ell r}\\sim N(0,\\Sigma_\\ell)$, calibration weights give $X_q=\\theta A_qV+Z_q$, where $Z_q\\sim N(0,\\Sigma_q)$ and $\\Sigma_q=\\sum_{\\ell,r}q_{\\ell r}^2\\Sigma_\\ell/\\lVert q\\rVert_2^2$. For the equal-magnitude $k$-sparse signals in the theorem, a sufficient support-recovery condition is $\\theta^2A_q^2\\gtrsim k\\max_j(\\Sigma_q)_{jj}\\log(d/\\delta)$. **Thus non-isotropic Gaussian noise changes the recovery threshold but does not remove the calibrated mean signal.** A common covariance yields a generalized spiked-covariance model, while source-dependent covariances yield a heteroscedastic problem. The exact identity-background sparse-PCA equivalence and hardness comparison remain confined to the original isotropic model. We also tested AR(1) and block-correlated Gaussian noise, source-dependent scales, Rademacher noise, bounded uniform noise, and standardized Student-$t_8$ noise; the non-Gaussian cases will be presented as robustness experiments rather than theorem consequences.\n\n> **(4) Sample splitting**\n\n**No downstream observations are spent estimating the calibration weights: they are obtained exclusively from the 240 separately recorded calibration trials.** Thus the main method does not require splitting the scarce micro-source downstream samples to estimate $q$, and the calibration graph is fixed before downstream training or testing. For downstream evaluation, each source-task-class combination has 20 complete trials, split **12/4/4 into training/validation/test sets before window extraction**; consequently, windows from the same trial never cross splits. Sample splitting is relevant only to comparison methods that estimate alignment from downstream features: it may separate weight estimation from final averaging, but it does not make task-derived alignment task-independent.\n\n> **(5) Assumptions and validity**\n\nWe will distinguish task independence from calibration quality. Let $E$ contain only source-side structure fixed before the downstream task, and let $D_{\\mathrm{task}}$ contain downstream labels, observations, and feature noise. We define task-independent calibration by $\\mathfrak{M}\\perp(V,R,D_{\\mathrm{task}})\\mid(\\sigma,E)$. Missing edges, edge flips, heterogeneous reliability, and random metadata may reduce alignment while preserving task independence. **With $20\\\\%$ additional independent edge flips, the physical experiment gives an aligned fraction of $0.718\\pm0.029$ and balanced test accuracy of $0.852\\pm0.009$; at $40\\\\%$, these become $0.142\\pm0.038$ and $0.627\\pm0.014$.** For independent nonnegative sub-Gaussian amplitudes with positive mean $m_R$, the calibrated concentration argument extends with $m_R$ replacing $\\sqrt{2/\\pi}$, although the exact sparse-PCA identity still uses the Gaussian submodel. The current theorem also assumes an exactly $k$-sparse signal with equal-magnitude nonzero entries; we do not claim an approximate-sparsity theorem. Finally, the sign model isolates a minimal ambiguity, but calibrated guarantees for rotations, permutations, or nonlinear transformations require new arguments because imperfect alignment may not preserve sparsity. These limitations will move into the main paper.\n\n> **(6) Writing changes**\n\nWe will begin with the physical same/opposite-orientation example, derive the coefficient of $V$ in the weighted average, and only then introduce aligned mass. We will initially use \"source sign,\" \"same/opposite record,\" and \"metadata-derived source weights,\" while moving posterior alignment capacity after the concrete derivation or to the appendix. **Every symbol will be defined at first use.** This includes $e$ in $k\\log(ed/k)$, the sparsity notation $\\lVert v\\rVert_0$, the signal strength $\\theta$, the largest-eigenvalue notation $\\lambda_{\\max}$, the recovery tolerance $\\varepsilon_{\\mathrm{rec}}$, the inequality notation $\\gtrsim$, and the Bernoulli notation $\\operatorname{Ber}(p)$. We will also correct the Figure 1(a) legend, use \"Corr\" where only correlation is plotted, and describe random or shuffled controls as \"uninformative\" or \"mismatched\" rather than \"invalid.\" The revision will state directly that the algorithms are standard and that the contribution is the characterization of how calibration changes the available statistical signal."+ },+ "createdAt": "2026-07-27T04:36:17.134Z",+ "modifiedAt": "2026-11-18T17:12:18.561Z",+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ¬eId=93h9lZQCEk",+ "license": "CC-BY-4.0"+}
reviews/openreview/q5hpa44zej/notes/dr7qj1zktz.json added
+++ b/reviews/openreview/q5hpa44zej/notes/dr7qj1zktz.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "dr7QJ1zKTz",+ "replyTo": "GguGV8f17x",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for being direct about the exposition. We address your concerns one by one below.\n\n> **(1) Main terminology**\n\nThe revision will begin with the following concrete description: **Each source represents the same sparse direction using either the $+V$ or $-V$ convention, and calibration records whether two sources use the same or opposite convention.** Here $V\\in\\mathbb R^d$ is the direction to be learned and $\\sigma_\\ell\\in\\{-1,+1\\}$ is the convention used by source $\\ell$. We will use “source sign” for this convention, “same/opposite record” for a noisy comparison $C_{\\ell m}$ between two sources, “synchronization” for estimating one sign per source up to a global sign, and “metadata-derived weights” for the resulting averaging weights. A relative-polarity log is an operational record from which a same/opposite sign can be extracted, while an absolute-orientation record estimates one source’s sign relative to a known reference. We will avoid “gauge section” initially and describe “linearization” simply as aligned averaging that restores a mean signal.\n\n> **(2) Validity variables**\n\nLet $\\mathfrak M$ denote calibration metadata, $\\sigma$ the source signs, and $E$ source-side structure fixed independently of the downstream task, such as source identities, source sizes, graph topology, and the pre-specified calibration design. Let $D_{\\rm task}$ collect downstream labels, observations, and feature noise. We will define task-independent calibration by $\\mathfrak M\\perp(V,R,D_{\\rm task})\\mid(\\sigma,E)$. **Thus calibration may depend on the source conventions and pre-specified calibration design, but not on the downstream direction, labels, observations, amplitudes, or noise.** In particular, $E$ cannot encode downstream labels or features. Validity concerns task independence rather than accuracy: random metadata can be valid but useless, whereas feature- or label-derived alignment may be useful but is task-coupled.\n\n> **(3) Downstream task**\n\n**In the main theory, the downstream task is to recover $V$ or its support $\\operatorname{supp}(V)=\\{j:V_j\\neq0\\}$ after calibration has been collected.** In the two-view example, the recovered direction is used in a binary classifier. In the physical IMU study, calibration is collected from a prescribed reference motion and the resulting source alignment is reused for four positive-versus-negative directed-motion classification tasks.\n\n> **(4) Weights and aligned mass**\n\nSuppose calibration estimates one sign $\\widehat s_\\ell$ for each source, and every observation from source $\\ell$ is assigned weight $q_{\\ell r}=\\widehat s_\\ell$. If $g_{\\ell r}=\\sigma_\\ell$ and $W_{\\ell r}=\\theta\\sigma_\\ell V+\\varepsilon_{\\ell r}$, then\n$X_q=\\sum_{\\ell,r}q_{\\ell r}W_{\\ell r}/\\|q\\|_2=\\theta(q^\\top g/\\|q\\|_2)V+Z$, where $Z\\sim N(0,I_d)$. **This directly motivates $M_q(g)=(q^\\top g)^2/\\|q\\|_2^2$, because $\\theta^2M_q(g)$ is exactly the squared restored mean-shift strength.** Perfect alignment gives $M_q(g)=n$, and $M_q(g)/n$ is the squared cosine similarity between $q$ and $g$. Aligned mass is not an algorithm input. If retained in the main text, $\\Gamma(\\mathfrak M,E)=\\mathbb E[\\sigma\\sigma^\\top\\mid\\mathfrak M,E]$ will be introduced as the posterior correlation matrix of the source signs, and $\\mathcal C(\\mathfrak M,E)=s\\lambda_{\\max}(\\Gamma(\\mathfrak M,E))$ as the largest posterior expected aligned mass for equal source sizes. Under independent Rademacher signs, source labels give $\\mathcal C=s$, while perfect calibration gives $\\mathcal C=n$. Because these channel-level quantities are not required by the algorithm, we will introduce them only after the weighted-average calculation or move them to the appendix.\n\n> **(5) Concrete example**\n\n**Operationally, calibration means recording a prescribed reference motion before the downstream tasks and using it to determine whether two fixed sensor mountings have the same or opposite axis orientation.** We use **24 fixed device-mounting sources**, each with **10 separately recorded calibration trials**. The ten time-normalized traces are aggregated into one reference trace per source, and the signs of pairwise correlations produce a complete graph of $\\binom{24}{2}=276$ same/opposite records. The graph is synchronized once and reused unchanged across all four downstream tasks; calibration and downstream recordings are separate. **Relative calibration achieves macro balanced test accuracy $0.902\\pm0.006$, versus $0.921\\pm0.004$ with oracle mounting signs and $0.558\\pm0.011$ without calibration.** Recorded mounting signs are used only for alignment evaluation and the oracle baseline, not for graph construction, synchronization, or ordinary classifier training. This physical example will precede the abstract terminology in the revision.\n\n\n> **(6) Presentation changes**\n\nWe will derive the weighted-average signal before defining aligned mass, define every symbol at first use, explain the sparse-PCA and sparse-mean experiments side by side, move the main limitations into the paper body, and distinguish theorem tests, controlled real-feature tests, and the physical study. Each main result in Section 3 will begin with its statistical meaning, observation model, and recovery target. For example, $\\mathcal V_{d,k}$ is the set of $d$-dimensional vectors with exactly $k$ nonzero entries, each equal to $\\pm1/\\sqrt{k}$, and $K_{\\rm sp}=k\\log(ed/k)$, where $e$ is Euler’s number. **The same/opposite-source mechanism will lead the exposition rather than appear after the abstract definitions.** We will also correct the Figure 1(a) legend, use “Corr” where only correlation is plotted, and replace “invalid metadata” with “uninformative” or “mismatched metadata” for random and shuffled controls."+ },+ "createdAt": "2026-07-27T04:22:02.247Z",+ "modifiedAt": "2026-11-18T17:12:17.951Z",+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ¬eId=dr7QJ1zKTz",+ "license": "CC-BY-4.0"+}
reviews/openreview/q5hpa44zej/notes/ggugv8f17x.json added
+++ b/reviews/openreview/q5hpa44zej/notes/ggugv8f17x.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "GguGV8f17x",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer qcKQ",+ "content": {+ "summary": "The paper studies sparse multi-source learning when sign gauge metadata is available. The authors show that source labels alone only reduce the multi-source learning problem to sparse PCA, whereas calibration metadata can turn the same problem into a sparse mean recovery problem, which is statistically easier. The theory is evaluated on synthetic and semi-synthetic datasets.",+ "contribution_type": "theory",+ "strengths_and_weaknesses": "I think the paper is very difficult to follow. The writing uses many technical terms such as relative polarity logs, relative-gauge metadata, source-structure variables, etc, which I think do not seem standard in ML. I am not sure whether this is because I am not familiar with the literature, or because the paper does not define its terminology clearly enough. In any case, many of these terms are introduced in an abstract way without detailed explanation. This makes the paper confusing to read.",+ "quality": 1,+ "clarity": 1,+ "significance": 1,+ "originality": 2,+ "questions": "- Could the authors define the main terminology used throughout the paper more clearly? For example, relative polarity logs, orientation edges, noisy absolute orientation records, etc?\n\n- In Section 2.2, what exactly are the source-structure variables $E$? Please provide concrete definitions and/or examples. \nAlso Definition 1 introduces several variables that were not introduced in Section 2.1, such as $Y,\\Xi,Z$. What exactly are the downstream labels, feature noise, and other nuisance variables in the context of the observation model in Section 2.1? \n\n- What exactly is the \"downstream task\" in the paper? \n\n- Section 2.3 is very hard to follow. It introduces $q$, $M_q(g)$, aligned mass, posterior alignment capacity, and $\\Gamma(M,E)$, but gives little intuition before the definitions. Where does the weighting $q$ come from, and why is $M_q(g)$ the right quantity to define? \n\n- I can understand the high-level message from the titles of subsection in Section 3, but the detailed writing is difficult to follow.",+ "limitations": "The paper discusses limitations in Appendix E, not in the main paper.",+ "rating": 3,+ "confidence": 2,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No major concerns.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The rebuttal clarified the main terminology, calibration setting, downstream task, and motivation for aligned mass, so I raised my score from reject to borderline reject. However, several proofs remain too concise and lack sufficient details or references."+ },+ "createdAt": "2026-07-07T14:50:49.637Z",+ "modifiedAt": "2026-11-18T13:36:37.789Z",+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ¬eId=GguGV8f17x",+ "license": "CC-BY-4.0"+}
reviews/openreview/q5hpa44zej/notes/jeo2eliook.json added
+++ b/reviews/openreview/q5hpa44zej/notes/jeo2eliook.json@@ -0,0 +1,31 @@+{+ "schema": "review/1",+ "id": "jEO2elIoOK",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Exff",+ "content": {+ "summary": "The paper studies a sparse Gaussian model where source labels alone do not reveal the relative sign gauges across sources. It shows that without calibration, the source-labelled experiment reduces to sparse PCA, while valid relative-gauge metadata enables synchronization and turns the problem into sparse mean recovery.",+ "contribution_type": "theory",+ "strengths_and_weaknesses": "Pros.\n\nThe paper is conceptually clear and focuses on a clean distinction between grouping information and calibration information. The reduction from uncalibrated source-labelled learning is elegant, and the calibrated sparse-mean viewpoint provides a useful way to formalize the value of task-independent metadata. The experiments are well aligned with the theory and validate the main mechanisms, in particular, I like Fig 1.\n\nCons.\n\n1 The formulation is highly stylized. The analysis focuses on sparse Gaussian observations with source-specific (Z_2) sign gauges, while practical multi-source shifts may involve richer transformations such as permutations, rotations, scalings or nonlinear trasformation\n\n2 Most experiments are synthetic or controlled real-feature studies where gauges and calibration logs are imposed artificially.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "See weaknesses.",+ "limitations": "yes",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "N/A",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes"+ },+ "createdAt": "2026-06-27T08:13:57.486Z",+ "modifiedAt": "2026-11-18T13:36:39.959Z",+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ¬eId=jEO2elIoOK",+ "license": "CC-BY-4.0"+}
reviews/openreview/q5hpa44zej/notes/njpjger7jx.json added
+++ b/reviews/openreview/q5hpa44zej/notes/njpjger7jx.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "nJPJGeR7jX",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "The paper studies sparse multi-source learning under source-specific sign gauges. It argues that source labels alone reduce the problem to sparse PCA, whereas valid relative-gauge metadata enables source synchronization and transforms the problem into sparse mean recovery. The paper introduces aligned mass to quantify the first-order signal restored through calibration and derives statistical and conditional computational separations in a micro-source regime.\n\nThe reviews are mixed. Reviewer Exff regards the distinction between grouping information and calibration information as conceptually clear, finds the sparse-PCA reduction elegant, and views the calibrated sparse-mean formulation as a useful way to formalize the value of task-independent metadata. Reviewer C2EK also finds the theoretical framing well structured and considers the connection among synchronization overlap, aligned mass, and downstream recovery potentially novel. Both reviewers find the experiments consistent with the theoretical predictions.\n\nAt the same time, the reviewers identify substantial limitations. Reviewers Exff and C2EK emphasize that the formulation is highly stylized, relying on Z_2 sign gauges, Gaussian isotropic noise, exact sparsity, independent source amplitudes, and a strong validity condition on the metadata. C2EK further notes that the main algorithmic components—spectral synchronization, weighted averaging, and top-k thresholding—are standard, and that the conceptual conclusion becomes relatively straightforward once reliable relative-sign metadata is available.\n\nA recurring concern is the absence of a sufficiently concrete real-world source of valid calibration metadata. C2EK finds the practical origin of such metadata vague and notes that the experiments impose gauges and calibration information artificially. Exff similarly observes that most experiments are synthetic or controlled real-feature studies. Ko3y requests specific multi-source examples relevant to the NeurIPS community and a clearer explanation of how the experimental validation connects to the theoretical setting. Thus, while the experiments support the claims within the proposed model, the reviewers question whether they establish broader practical relevance.\n\nThe presentation is another significant weakness. Reviewer qcKQ finds the paper very difficult to follow because many nonstandard or abstract terms are introduced without sufficient explanation or intuition. C2EK similarly describes the writing as unnecessarily jargon-heavy and identifies several notation and presentation issues. Ko3y also requests more intuitive examples and asks how aligned mass should be interpreted when the source gauges are unknown.\n\nThe author response could affect the assessment if it provides concrete and credible examples of naturally occurring task-independent calibration metadata, clarifies the novelty beyond standard synchronization and sparse-recovery tools, and better explains the operational meaning of aligned mass. The authors should also clarify the connection between the theory and experiments and discuss robustness beyond the idealized assumptions, including correlated or source-dependent noise and approximate metadata validity. Improvements to terminology and exposition would be helpful, but presentation changes alone would not resolve the concerns about scope and significance.",+ "final_justification": "I have carefully read the authors' rebuttal and the subsequent discussion. The response substantially addressed the main concerns raised in my initial meta-review. In particular, the authors provided a concrete physical calibration setting, clarified the operational meaning of aligned mass and the connection between theory and experiments, and better positioned the main contribution as a statistical characterization rather than a new synchronization algorithm.\n\nSome limitations remain. The theoretical setting is relatively stylized, and several proofs in the current version are overly concise. In particular, the discussion identified issues concerning the concentration argument in Lemma 6 and the packing/Fano argument in Theorem 8. The authors provided additional arguments addressing these points, but the corresponding proofs and citations should be carefully strengthened in the revision.\n\nOverall, the rebuttal materially improved my assessment. I find the characterization of how calibration changes the problem from sparse PCA to sparse mean recovery, together with the resulting statistical separation, to be a clean and meaningful theoretical contribution. Taking the reviews, the rebuttal, and the subsequent discussion into account, I recommend acceptance."+ },+ "createdAt": "2026-09-24T11:17:44.007Z",+ "modifiedAt": "2026-11-18T14:53:16.363Z",+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ¬eId=nJPJGeR7jX",+ "license": "CC-BY-4.0"+}
reviews/openreview/q5hpa44zej/notes/npdzjv3ssa.json added
+++ b/reviews/openreview/q5hpa44zej/notes/npdzjv3ssa.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "NpDZjV3ssa",+ "replyTo": "jEO2elIoOK",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for the detailed review. We address the specific questions below.\n\n> **(1) Physical metadata**\n\n**This experiment uses a physically induced sign convention and separately acquired calibration metadata, rather than gauges imposed on stored features.** We use **24 fixed device-mounting sources**, each contributing **10 separately recorded reference-motion trials** (**240 calibration trials**). For each source, the ten time-normalized traces are aggregated into one reference trace; the sign of the correlation for each source pair defines one noisy same/opposite record, producing a complete undirected graph with $\\binom{24}{2}=276$ edges. No downstream labels, downstream recordings, or task-derived features enter this graph. Recorded mounting signs are used only to evaluate alignment and construct the oracle baseline. They are not used to construct the graph, perform relative synchronization, or train the ordinary downstream classifier.\n\n| Method | Balanced test accuracy | Aligned fraction $M_q/n$ |\n|---|---:|---:|\n| Oracle mounting polarity | $0.921\\pm0.004$ | $1.000\\pm0.000$ |\n| **Relative calibration + synchronization** | **$0.902\\pm0.006$** | **$0.916\\pm0.015$** |\n| No calibration | $0.558\\pm0.011$ | $0.044\\pm0.010$ |\n| Shuffled metadata | $0.553\\pm0.012$ | $0.040\\pm0.009$ |\n\nThe downstream dataset contains $24\\times4\\times2\\times20=3{,}840$ complete trials. Within every source-task-class combination, its 20 trials are split **12/4/4 into training/validation/test sets before window extraction**, yielding **2,304/768/768 complete trials**; windows from the same trial never cross splits. **The graph is constructed and synchronized once, and the resulting source alignment is reused unchanged across the four tasks, obtaining balanced accuracies $0.928$, $0.905$, $0.892$, and $0.883$ (macro average $0.902$).** Uncertainty is computed by cluster bootstrap at the device-mounting-source level. The revision will additionally specify the hardware, trace processing, classifier, and bootstrap implementation.\n\n> **(2) Why sign gauges?**\n\nWe agree that practical transformations may include rotations, permutations, scaling, and nonlinear drift. The multiplicative sign group $\\{\\pm1\\}$, which is isomorphic to $\\mathbb Z_2$, isolates the smallest source ambiguity that can eliminate first-order pooling. Under $W_{\\ell r}=\\theta R_\\ell\\sigma_\\ell V+\\varepsilon_{\\ell r}$ and the i.i.d. Rademacher-gauge model, the marginal source aggregate has zero mean and retains only the covariance spike $VV^\\top$. **Thus, even a one-bit source convention is sufficient to change a sparse-mean problem into sparse PCA.** Any broader minimax class containing this model as a submodel, with the same observation protocol and recovery target, inherits its lower bound. The calibrated upper bound does not automatically extend to arbitrary transformations: for rotations $G_\\ell\\in O(d)$, imperfect alignment acts on $V$ through an operator that need not preserve sparsity. We will state this boundary explicitly.\n\n> **(3) Non-isotropic noise**\n\nFor source-dependent Gaussian noise, let source $\\ell$ have covariance $\\Sigma_\\ell$. Calibration still gives a weighted observation of the form $X_q=\\theta A_qV+Z_q$. Define $S_q=\\sum_{\\ell,r}q_{\\ell r}^2$. The noise term $Z_q$ is Gaussian with covariance $\\Sigma_q=S_q^{-1}\\sum_{\\ell,r}q_{\\ell r}^2\\Sigma_\\ell$. **The calibrated mean signal survives; non-isotropic noise changes the recovery threshold rather than removing the first-order signal.** Let $v_q$ be the largest diagonal entry of $\\Sigma_q$. For the equal-magnitude $k$-sparse signals in our theorem, a sufficient recovery condition is $\\theta^2A_q^2\\geq Ckv_q\\log(d/\\delta)$ for a universal constant $C$. A common covariance gives a generalized spiked-covariance problem, whereas source-dependent covariances give a heteroscedastic problem. The exact standard sparse-PCA equivalence and hardness comparison remain limited to the identity-covariance Gaussian model. We also added robustness experiments with correlated, heteroscedastic, bounded, and heavy-tailed noise.\n\n> **(4) Experimental scope**\n\nWe will separate the evidence into three levels: synthetic Gaussian experiments test the theorem’s sparse-mean and sparse-PCA scaling; controlled scikit-learn experiments test cancellation and restoration using real features with imposed source signs; and the physical IMU study tests independently collected calibration, synchronization, corruption, and reuse. **The physical study provides a concrete acquisition mechanism for the sign-gauge case, not evidence for arbitrary multi-source transformations.** We will make that scope explicit in the main paper."+ },+ "createdAt": "2026-07-27T04:24:21.830Z",+ "modifiedAt": "2026-11-18T17:12:17.907Z",+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ¬eId=NpDZjV3ssa",+ "license": "CC-BY-4.0"+}
reviews/openreview/q5hpa44zej/notes/p3ap5sdzou.json added
+++ b/reviews/openreview/q5hpa44zej/notes/p3ap5sdzou.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "P3Ap5sDzoU",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Ko3y",+ "content": {+ "summary": "This work proposes a method for aligning data sources using metadata. They propose the concept of aligned mass to quantify the value of metadata. Then they provide a theory supporting their method, including showing that only source labels reduce data alignment to spare PCA, and more metadata is reduced to a sparse mean problem. They propose a method for computational and statistical separation in a micro-source regime. Finally, they test their theories on synthetic datasets and two scikit-learn datasets.",+ "contribution_type": "theory",+ "strengths_and_weaknesses": "This appears to be a work with a strong theoretical contribution. Unfortunately, my limited experience in the field and the related literature make it difficult for me to determine whether there is sufficient novelty in this submission for a NeurIPS conference paper.\n\n**Quality**\nThe paper seems to be of high quality and technically sound. It provides a large amount of theory, but misses specific examples and an intuitive explanation of the proposed method. Due to time constraints, I was unable to rigorously check all the proofs in the manuscript.\n\n**Clarity** \nThe work is clearly written and well-organized. However, it misses a clear tie between the experimental validation and the theory.\n\n**Significance**\nDue to my limited experience in the field, I cannot confidently comment on this paper's significance. But the problem seems sufficiently general to be applicable to a wide variety of fields.\n\n**Originality**\nI believe that the concept of aligning data from different sources via their metadata is a well-studied problem and likely has been addressed in many prior works. Therefore, I'm not convinced that these concepts have not already been considered in prior work.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 2,+ "questions": "Major points:\n1) In the introduction and perhaps in the theory section, can you provide some specific examples of these types of multisource learning problems and argue why they are relevant problems to the Neurips community?\n2) In the real-feature experiment with scikit-learn datasets, what is the SE that you are measuring? What are you predicting in these experiments? In general, can you provide a clearer logical transition between the theory and experiments?\n3) How can you compute *aligned mass* when you do not know the source gauges?\n\n\nSmall points:\n- Line 69: Do you mean vectors with entries within the set $\\{0, 1/\\sqrt{k}, -1/\\sqrt{k}\\}$, right? Also, what is $ed$ in the definition of $K_{sp}$?\n- Line 72: What is $\\theta$?\n- Line 129: Can you define the Rademacher gauge prior\n- Line 277: What gaps are you referring to when you say \"Sparse PCA is a standard model for high-dimensional statistical and computational gaps?\"",+ "limitations": "Limitations appear in the appendix and are adequate. Perhaps they should be discussed further in the main text.",+ "rating": 3,+ "confidence": 1,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No major concerns.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The authors provided an additional physical experiment and clarified some details (see small points). I will however, maintain my score as the authors did not adequately respond to issues regarding the intuition behind this work and the framing of the problem they address and it's relevance to the larger Neurips community.\n\nI keep my confidence rating low because I am not an expert in the field and did not carefully check the mathematical details."+ },+ "createdAt": "2026-06-08T09:28:56.050Z",+ "modifiedAt": "2026-11-18T13:36:42.086Z",+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ¬eId=P3Ap5sDzoU",+ "license": "CC-BY-4.0"+}
reviews/openreview/q5hpa44zej/notes/utvjqd0gie.json added
+++ b/reviews/openreview/q5hpa44zej/notes/utvjqd0gie.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "UTvjQd0Gie",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair XiVs",+ "content": {+ "metareview": "The paper studies sparse multi-source learning under source-specific sign gauges. It argues that source labels alone reduce the problem to sparse PCA, whereas valid relative-gauge metadata enables source synchronization and transforms the problem into sparse mean recovery. The paper introduces aligned mass to quantify the first-order signal restored through calibration and derives statistical and conditional computational separations in a micro-source regime.\n\nThe reviews are mixed. Reviewer Exff regards the distinction between grouping information and calibration information as conceptually clear, finds the sparse-PCA reduction elegant, and views the calibrated sparse-mean formulation as a useful way to formalize the value of task-independent metadata. Reviewer C2EK also finds the theoretical framing well structured and considers the connection among synchronization overlap, aligned mass, and downstream recovery potentially novel. Both reviewers find the experiments consistent with the theoretical predictions.\n\nAt the same time, the reviewers identify substantial limitations. Reviewers Exff and C2EK emphasize that the formulation is highly stylized, relying on Z_2 sign gauges, Gaussian isotropic noise, exact sparsity, independent source amplitudes, and a strong validity condition on the metadata. C2EK further notes that the main algorithmic components—spectral synchronization, weighted averaging, and top-k thresholding—are standard, and that the conceptual conclusion becomes relatively straightforward once reliable relative-sign metadata is available.\n\nA recurring concern is the absence of a sufficiently concrete real-world source of valid calibration metadata. C2EK finds the practical origin of such metadata vague and notes that the experiments impose gauges and calibration information artificially. Exff similarly observes that most experiments are synthetic or controlled real-feature studies. Ko3y requests specific multi-source examples relevant to the NeurIPS community and a clearer explanation of how the experimental validation connects to the theoretical setting. Thus, while the experiments support the claims within the proposed model, the reviewers question whether they establish broader practical relevance.\n\nThe presentation is another significant weakness. Reviewer qcKQ finds the paper very difficult to follow because many nonstandard or abstract terms are introduced without sufficient explanation or intuition. C2EK similarly describes the writing as unnecessarily jargon-heavy and identifies several notation and presentation issues. Ko3y also requests more intuitive examples and asks how aligned mass should be interpreted when the source gauges are unknown.\n\nThe author response could affect the assessment if it provides concrete and credible examples of naturally occurring task-independent calibration metadata, clarifies the novelty beyond standard synchronization and sparse-recovery tools, and better explains the operational meaning of aligned mass. The authors should also clarify the connection between the theory and experiments and discuss robustness beyond the idealized assumptions, including correlated or source-dependent noise and approximate metadata validity. Improvements to terminology and exposition would be helpful, but presentation changes alone would not resolve the concerns about scope and significance."+ },+ "createdAt": "2026-07-23T14:12:10.262Z",+ "modifiedAt": "2026-11-18T15:19:27.514Z",+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ¬eId=UTvjQd0Gie",+ "license": "CC-BY-4.0"+}
reviews/openreview/q5hpa44zej/notes/vwvxciph4l.json added
+++ b/reviews/openreview/q5hpa44zej/notes/vwvxciph4l.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "vwVXciph4l",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer C2EK",+ "content": {+ "summary": "Summary:\nThe paper studies a sparse Gaussian multi-source model in which each source observes the same sparse direction through an unknown source-specific sign gauge. It distinguishes source labels, which identify sample groups, from calibration metadata, which carries information about source orientation. The main results show that (1) source-labelled but uncalibrated observations provide no more information than the corresponding sparse-PCA experiment; (2) valid metadata about whether pairs of sources are aligned or flipped can be synchronized to produce a sparse mean recovery problem. The paper introduces \"aligned mass\" to quantify the first-order signal restored by metadata-induced alignment.\n\nSummary of evaluation:\nThis is a theoretical paper that studies a high-level statistical question under a narrow but clearly specified model. The model and the results within this model seem novel, although the proof tools and the basic algorithmic components are standard. The experiments support the main theoretical predictions, but they could have been broader and more connected to real-world calibration metadata. Overall significance is moderate because of the limited modeling assumptions and the synthetic or controlled nature of the experiments. The presentation could also be substantially clearer. Overall, I think the paper could be an interesting addition to the proceedings.",+ "contribution_type": "theory",+ "strengths_and_weaknesses": "Strengths:\n\n* The theoretical framing is well structured and the message is clear. \n* Proposition 3 gives an exact sparse-PCA reduction for the source-labelled uncalibrated experiment: after source aggregation, X_\\ell ~ N(0, I_d + \\lambda V V^T), with residual noise independent of V. Thus, in the regime of few samples per source, labels alone leave only second-order information.\n* The second contribution assumes calibration metadata that records relative-signs between samples. This is plausible, although more concrete examples should have been given in the paper. Once the metadata is used to align the sources, the weighted average X_q becomes a sparse mean observation. The recovery theorem then follows from standard top-k sparse mean recovery plus concentration for random source amplitudes.\n* The relative-sign graph model and the use of spectral Z_2 synchronization seems standard, but the connection from synchronization overlap to aligned mass and downstream recovery seems novels.\n* The synthetic and controlled experiments support the main theoretical predictions within the narrow modeling assumptions.\n\nWeaknesses:\n\n* The main conceptual message is rather simple: source labels do not determine source orientation (without sufficient samples per source), whereas valid calibration metadata can restore the mean signal. Much of the theory formalizes a fact that is algorithmically straightforward once the calibration information is available.\n* The algorithmic novelty is limited. The computational ingredients are standard: spectral synchronization, weighted averaging, and top-k thresholding. \n* The model is narrow: Z_2 sign gauges, Gaussian isotropic noise, exact sparsity, independent source amplitudes, and a strong validity condition for metadata. The paper acknowledges this, but it limits direct applicability. More importantly, the paper does not give a concrete real-world example of valid calibration metadata. While the modeling is clear, the source of such metadata in realistic pipelines remains vague.\n* The given synthetic and controlled real-feature experiments validate the theory, but that's expected unless there were a mistake in the proofs. How close do we get with real-world metadata? That would have been a more interesting study.\n* Real world data may have correlated or source-dependent feature noise. In that case, the background covariance is not identity but, a typically unknown, matrix. Does/can the theory extend to these cases, or give useful bounds on the distance from its ideal case?\n* The role of sample splitting (e.g., mentioned in Section 2.2) should be clarified. Theorem 4 requires the section q to be independent of the feature noise on the linearization split. If q is estimated from task data, then sample splitting may leave too little data for the estimation in the micro-source regime where s is small. Some discussion is needed.\n* The writing is unnecessarily jargon-heavy. Terms such as gauge section, aligned mass, posterior alignment capacity, and linearization make a simple idea harder to parse than necessary. This is especially true in the abstract/introduction where conveying the point in simpler terms is needed.\n* There are various notation/presentation problems. Examples include e in k log(e d/k), ||v||_0, theta, lambda_{max}, epsilon_{rec}, gtrsim, and Ber(p), which are undefined before first use as conventional but they can be ambiguous.",+ "quality": 3,+ "clarity": 2,+ "significance": 3,+ "originality": 3,+ "questions": "Please address the weaknesses above.",+ "limitations": "The limitations are clearly discussed in the Weaknesses section. Most of them have to do with the limitations of the model and the lack of experiments on real-world metadata.",+ "rating": 4,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No concerns.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The authors acknowledged the weaknesses I raised for the paper, and I hope the revised version will improve clarity. \nMy score stays at the same level as this is indeed a solid technical work, but not of \"high potential value on at least one sub-area of AI\" and too narrow to have a \"moderate-to-high impact on more than one area of AI\"."+ },+ "createdAt": "2026-06-25T08:39:42.068Z",+ "modifiedAt": "2026-11-18T13:36:41.055Z",+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ¬eId=vwVXciph4l",+ "license": "CC-BY-4.0"+}
reviews/openreview/q5hpa44zej/notes/xwkoveioa8.json added
+++ b/reviews/openreview/q5hpa44zej/notes/xwkoveioa8.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "xwkovEiOA8",+ "replyTo": "P3Ap5sDzoU",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for identifying the need for a concrete example and a clearer bridge from theory to experiments. We address both below.\n\n> **(1) Multi-source example**\n\n**We added a physical multi-source example in which calibration records are collected independently rather than imposed synthetically.** The study uses **24 fixed device-mounting sources**, each with **10 separately recorded calibration trials**. The ten time-normalized traces are aggregated into one reference trace per source, and pairwise correlation signs form a complete graph of $\\binom{24}{2}=276$ same/opposite-orientation records. The graph is synchronized once and reused unchanged across four downstream tasks. The downstream dataset contains $24\\times4\\times2\\times20=3{,}840$ complete trials, split **12/4/4 within each source-task-class before window extraction**. Calibration and downstream recordings are separate, and mounting signs are used only for evaluation and the oracle baseline. **Relative calibration achieves macro balanced test accuracy $0.902\\pm0.006$, versus $0.921\\pm0.004$ for oracle polarity, $0.558\\pm0.011$ without calibration, and $0.553\\pm0.012$ with shuffled metadata.** This setting is relevant whenever sources have stable coordinate conventions, including sensor polarity, mounting orientation, scanner orientation, instrument-response conventions, and latent factors identifiable only up to sign.\n\n> **(2) Theory and experiments**\n\nThe synthetic Gaussian experiments recover a planted sparse direction and test the predicted sparse-mean and sparse-PCA scaling laws. The digits experiment comprises five binary tasks: $0$ vs. $6$, $1$ vs. $7$, $2$ vs. $5$, $3$ vs. $8$, and $4$ vs. $9$. These tasks use real image features with controlled source signs. The breast-cancer experiment predicts malignant versus benign under the same intervention. **The physical IMU experiment tests the remaining practical step: whether independently collected calibration can align real sensor recordings and be reused across tasks.** It contains **3,840 complete downstream trials** across four positive-versus-negative directed-motion tasks, with **12/4/4 trial-level train/validation/test splits within each source-task-class before window extraction**. The same calibration graph and synchronized source alignment are reused unchanged for all four tasks. **Thus, the synthetic experiments test the formal model, the scikit-learn experiments test the mechanism using non-Gaussian real features, and the IMU experiment tests whether calibration can be collected before the downstream task.** For the controlled real-feature tables, let $m_b$ be the test accuracy from seed $b$ after the stated task aggregation. For digits, $m_b$ is averaged across the five digit-pair tasks. With $B=30$ seeds, the reported standard error is $\\operatorname{sd}(m_1,\\ldots,m_B)/\\sqrt{B}$. The reuse table instead reports variability across 32 downstream tasks sharing one calibration graph; we will correct the appendix sentence that currently groups this experiment with the 30-seed experiments. For the physical study, uncertainty is obtained by cluster bootstrap at the device-mounting-source level. **Complete trials, rather than derived windows, are the splitting unit, so no trial contributes windows to more than one of training, validation, and testing.** The revision will report all aggregation, splitting, preprocessing, and uncertainty units explicitly.\n\n> **(3) Unknown signs**\n\nAligned mass is not needed to run the algorithm. Let $q\\in\\mathbb{R}^n$ be the calibration-derived weights and $g\\in\\{-1,+1\\}^n$ the unknown sample signs. We define aligned mass as $M_q(g)=(q^\\top g)^2/\\lVert q\\rVert_2^2$; therefore, $M_q(g)/n$ is the squared cosine similarity between $q$ and $g$. In the constant-amplitude model, the weighted statistic is $X_q=\\theta(q^\\top g/\\lVert q\\rVert_2)V+Z$, where $Z\\sim N(0,I_d)$. **Therefore, $\\theta^2M_q(g)$ is exactly the squared directional mean-shift strength created by the calibration weights.** In simulations, planted signs are available for evaluation. In the physical study, mounting signs are recorded for evaluation but are never used to construct the graph or train the classifier. We also added a non-oracle audit. Let $\\widehat{s}$ denote the synchronized signs, let $u=\\widehat{s}/\\sqrt{L}$, and let $B_h$ be an independently held-out graph with edge probability $p_h$ and mean reliability $\\alpha$. Under the homogeneous independent-edge model, the estimator $\\widehat{\\beta^2}_{\\mathrm{raw}}=(1+u^\\top B_hu/(p_h\\alpha))/L$ is conditionally unbiased when $p_h$ and $\\alpha$ are known. **The audit has Pearson correlation $0.932$ and Spearman correlation $0.925$ with alignment evaluated from mounting signs, and mean absolute error $0.016$ over 560 synthetic trials.**\n\n> **(4) Originality**\n\nYou are right that metadata-based alignment and group synchronization are established topics. We do not claim that pairwise synchronization itself is new. Prior synchronization work studies recovery of latent group elements from noisy pairwise measurements, while orbit-recovery and multi-reference-alignment work studies signals observed under latent group actions. **Our contribution is to show that, under the Rademacher-gauge model, uncalibrated source-labelled data are statistically equivalent to sparse PCA plus noise independent of $V$, whereas relative calibration constructs a sparse-mean observation from the same downstream samples.** Aligned mass then connects synchronization quality to the restored first-order signal and to the resulting statistical and conditional computational separations. The relevant novelty is therefore the change induced in the downstream statistical experiment, rather than the synchronization routine itself. We will sharpen this distinction relative to the synchronization and orbit-recovery literature.\n\n> **(5) Undefined symbols**\n\nThe sparse parameter class consists of $d$-dimensional unit vectors with exactly $k$ nonzero entries, each equal to either $1/\\sqrt{k}$ or $-1/\\sqrt{k}$. Here, $d$ is the ambient dimension and $k$ is the sparsity level. We define the sparse-complexity term as $K_{\\rm sp}=k\\log(ed/k)$, where $e$ is Euler's number. The parameter $\\theta$ denotes the signal magnitude of each observation. Under the Rademacher gauge prior, each source sign is independently and uniformly sampled from the two signs $-1$ and $+1$. For sparse PCA with $N$ observations and spike strength $\\lambda$, the relevant information scale is $N\\lambda^2$. **The sparse-PCA gap is the conjectured separation between the information threshold and the polynomial-time hard regime.** In our notation, the information threshold is $N\\lambda^2\\asymp K_{\\rm sp}$. The conjectured hard regime satisfies $K_{\\rm sp}\\ll N\\lambda^2$ and $N\\lambda^2\\ll k^2$, up to logarithmic factors and standard scaling conditions. We will define each quantity at first use and move the main limitations, including identity-covariance Gaussian noise, exactly sparse equal-magnitude signals, sign gauges, and task-independent calibration, into the main paper."+ },+ "createdAt": "2026-07-27T04:49:50.308Z",+ "modifiedAt": "2026-11-18T17:12:18.205Z",+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ¬eId=xwkovEiOA8",+ "license": "CC-BY-4.0"+}
reviews/openreview/q5hpa44zej/submission.json added
+++ b/reviews/openreview/q5hpa44zej/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "Q5Hpa44zeJ",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 6681,+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ",+ "license": "CC-BY-4.0"+}
versions/v_hjgvqxni.json added
+++ b/versions/v_hjgvqxni.json@@ -0,0 +1,22 @@+{+ "date": "2026-04-28",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 6681,+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ",+ "reviews": "openreview/q5hpa44zej",+ "evidence": [+ "https://openreview.net/forum?id=Q5Hpa44zeJ"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=Q5Hpa44zeJ",+ "evidence": [+ "https://openreview.net/forum?id=Q5Hpa44zeJ"+ ]+}