Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:36 UTC · 6ff86150890f ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,22 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "Q5Hpa44zeJ"- }- ],- "title": "Can Metadata Fix the Gauge? Calibration Turns Sparse Multi-Source Learning from Sparse PCA into Sparse Mean Recovery",- "authors": [- "Yirong Xiang",- "Yibo Zhou"- ],- "abstract": "Source labels tell us where a sample came from, but not how that source oriented its coordinates. In a sparse Gaussian multi-source model with source-specific sign gauges, that distinction changes the learning problem. Without calibration, pooling across sources erases the mean signal, and the source-labelled experiment reduces to sparse PCA. With task-independent relative-gauge metadata, synchronization aligns sources and the same observations become a sparse mean problem. We formalize the value of metadata through AlignedMass, which quantifies how much first-order signal a metadata-induced alignment restores. Source labels create only limited AlignedMass, whereas valid calibration can create AlignedMass proportional to the full sample size. This yields a statistical separation in micro-source regimes and, under standard sparse-PCA hardness assumptions, a computational separation as well. Synthetic experiments check the predicted scaling; controlled real-feature and physical sensor studies examine sign cancellation, separately acquired calibration, and reuse across tasks.",- "year": 2026,- "venue": "NeurIPS 2026",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "5a12e0d0-4f42-473a-9f01-166258cf4216"}
paper.json added
+++ b/paper.json@@ -0,0 +1,12 @@+{+ "title": "Can Metadata Fix the Gauge? Calibration Turns Sparse Multi-Source Learning from Sparse PCA into Sparse Mean Recovery",+ "authors": [+ "Yirong Xiang",+ "Yibo Zhou"+ ],+ "abstract": "Source labels tell us where a sample came from, but not how that source oriented its coordinates. In a sparse Gaussian multi-source model with source-specific sign gauges, that distinction changes the learning problem. Without calibration, pooling across sources erases the mean signal, and the source-labelled experiment reduces to sparse PCA. With task-independent relative-gauge metadata, synchronization aligns sources and the same observations become a sparse mean problem. We formalize the value of metadata through AlignedMass, which quantifies how much first-order signal a metadata-induced alignment restores. Source labels create only limited AlignedMass, whereas valid calibration can create AlignedMass proportional to the full sample size. This yields a statistical separation in micro-source regimes and, under standard sparse-PCA hardness assumptions, a computational separation as well. Synthetic experiments check the predicted scaling; controlled real-feature and physical sensor studies examine sign cancellation, separately acquired calibration, and reuse across tasks.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}