HilbertGen-3D:Hilbert--Multifractal Conditioning for Topology-Aware 3D Generation
Update NeurIPS 2026 submission VW15Ze9uYz: 6 notes
@openreview[bot] · 2026-11-24 15:51 UTC · d144735d34d4 ·
reviews/openreview/vw15ze9uyz/notes/2r5pxjbkxg.json added
+++ b/reviews/openreview/vw15ze9uyz/notes/2r5pxjbkxg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "2R5PXjBkXg",+ "replyTo": "95ldBnvzSJ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the follow-up and agree that our previous phrase “slightly larger/more complicated” was imprecise and did not provide a clear explanation. We further elaborate the reason for the hyperparameter selection as follows:\n\nWe look at Table 4 of the paper, which showcases the result of the sensitivity experiment, and make the observations below:\n\n- (S={3,4,5}) is the only tested scale set that improves all four metrics relative to the smaller scale sets.\n- An MLP ratio of (4) gives the best 1-NNA-EMD and both COV results, while (3.5) gives the best 1-NNA-CD.\n- Resampler depth (4) gives the best 1-NNA-EMD and COV-CD, whereas depth (3) gives the best 1-NNA-CD and COV-EMD. \n- Bottleneck latents (128) gives the best CD- and EMD-based coverage, while smaller latent sets give better 1-NNA. \n(Q={1,2,3}) ties for the best COV-EMD and retains information-, correlation-, and higher-density-sensitive orders. As (Q) is a part of generalized dimension computation and primarily responsible for global information, we find this parameter set to be more reliable. \n\nThere are two additional concerns: 1. The hyperparameter set needs to demonstrate the computational cost advantage of the proposed algorithm, so we try not to use hyperparameters such as (S = {4,5,6}), which would greatly increase computation cost, though we have great confidence that it would improve performance, as it would greatly enhance the resolution of HMC signal. 2. When the increase in the computation cost is comparatively low, and two sets of hyperparameters have similar performance, we select the hyperparameters with more parameters, as the longer epoch, smaller stepsize, and larger batch size is expected to bring more stability. The selected configuration fits the S/4 budget, while the complete model still has lower measured training memory and faster training and sampling than the principal baselines. We do not intend to claim that this configuration uniquely optimizes every metric.\n\nWe hope the above explanations answer the reviewer’s questions and provide the necessary context. We thank the reviewer again for the detailed suggestions."+ },+ "createdAt": "2026-08-01T05:44:50.621Z",+ "modifiedAt": "2026-11-19T17:00:49.607Z",+ "url": "https://openreview.net/forum?id=VW15Ze9uYz¬eId=2R5PXjBkXg",+ "license": "CC-BY-4.0"+}
reviews/openreview/vw15ze9uyz/notes/95ldbnvzsj.json added
+++ b/reviews/openreview/vw15ze9uyz/notes/95ldbnvzsj.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "95ldBnvzSJ",+ "replyTo": "cf49W93G4N",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer tRjA",+ "content": {+ "comment": "I thank the authors for the detailed response. The planned addition of more side-by-side qualitative comparisons and a more structured discussion of global coherence, thin or articulated structures, and sample diversity would address my first concern. The clearer introduction and statement of contributions, together with the added discussion of evaluation metrics and their trade-offs, address my concerns regarding presentation and clarity. However, describing the selected configuration as \"slightly larger/more complicated\" does not clearly explain how the hyperparameters were selected based on the sensitivity studies and ablations. I encourage the authors to make the hyperparameter selection process fully explicit in the revision and clearly state how the sensitivity experiments supported that configuration and which criterion was used to balance the different metrics and computational cost. My main concerns would be addressed provided that this is clarified."+ },+ "createdAt": "2026-07-31T15:30:40.269Z",+ "modifiedAt": "2026-11-19T17:00:49.069Z",+ "url": "https://openreview.net/forum?id=VW15Ze9uYz¬eId=95ldBnvzSJ",+ "license": "CC-BY-4.0"+}
reviews/openreview/vw15ze9uyz/notes/d8jv5slzlb.json modified
+++ b/reviews/openreview/vw15ze9uyz/notes/d8jv5slzlb.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair UdrA","content": {- "metareview": "The paper uses multi-scale voxel measures serialized by a 3D Hilbert curve and fused with geometric tokens improves the quality, diversity, and efficiency of diffusion-based point-cloud generation. The reviewers prainse mathematical grounding, bottleneck-fusion architecture and experimental evaluations. The main weaknesses are in regards to presentation: (i) an unclear inference-time conditioning procedure, (ii) a potentially overstated “topology-aware” characterization for what may primarily be density and spatial-structure encoding. They also criticise missing evaluation metrics and decisive ablations such as MMD, Hilbert-only, and raw-voxel comparisons, notation issues that impede reproducibility, as well as limited evaluation beyond aligned ShapeNet categories, unclear orientation sensitivity and hyperparameter selection.\n\nThe AC leans towards BA but could increase their acceptance probability if the response clearly explains how unconditional samples obtain HMC conditioning at inference, demonstrates that no ground-truth test shape is required, clarifies invariance assumptions and the topology claim, supplies missing metrics or ablations and complete hyperparameters, and resolves the methodological ambiguities identified by the reviewers."+ "metareview": "The paper uses multi-scale voxel measures serialized by a 3D Hilbert curve and fused with geometric tokens improves the quality, diversity, and efficiency of diffusion-based point-cloud generation. The reviewers prainse mathematical grounding, bottleneck-fusion architecture and experimental evaluations. The main weaknesses are in regards to presentation: (i) an unclear inference-time conditioning procedure, (ii) a potentially overstated “topology-aware” characterization for what may primarily be density and spatial-structure encoding. They also criticise missing evaluation metrics and decisive ablations such as MMD, Hilbert-only, and raw-voxel comparisons, notation issues that impede reproducibility, as well as limited evaluation beyond aligned ShapeNet categories, unclear orientation sensitivity and hyperparameter selection.\n\nThe AC leans towards BA but could increase their acceptance probability if the response clearly explains how unconditional samples obtain HMC conditioning at inference, demonstrates that no ground-truth test shape is required, clarifies invariance assumptions and the topology claim, supplies missing metrics or ablations and complete hyperparameters, and resolves the methodological ambiguities identified by the reviewers.",+ "final_justification": "Besides the already positive scores, the authors provided a substantial rebuttal. Finally, all reviewers recommend accepting this paper. The AC agrees."},"createdAt": "2026-07-19T15:51:31.700Z",- "modifiedAt": "2026-11-18T15:19:38.588Z",+ "modifiedAt": "2026-11-19T04:59:48.381Z","url": "https://openreview.net/forum?id=VW15Ze9uYz¬eId=D8jv5SlzLB","license": "CC-BY-4.0"}
reviews/openreview/vw15ze9uyz/notes/ssibbw5dma.json added
+++ b/reviews/openreview/vw15ze9uyz/notes/ssibbw5dma.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "sSibBW5DmA",+ "replyTo": "Qk26wcTzlR",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer YB4a",+ "content": {+ "comment": "I thank the authors for the thorough response to my comments. The issues I originally raised were mostly addressed, and I believe the presentation of the paper could be improved in the camera ready revision.\nMy main concerns remain around the limitations I pointed out, which were also acknowledged by the authors. The paper undoubtedly introduces some valuable ideas, but I believe the current standard for a 3D generation model, defined by the most recent literature on the topic, goes beyond categorical data with taxing assumptions such as consistent orientation.\nAdditionally, the answer in point 9 suggests that the model presents a performance tradeoff in settings where the training dataset is not available at inference time. This is a somewhat minor limitation but should still be explicitly stated."+ },+ "createdAt": "2026-07-31T13:06:30.700Z",+ "modifiedAt": "2026-11-19T17:00:49.628Z",+ "url": "https://openreview.net/forum?id=VW15Ze9uYz¬eId=sSibBW5DmA",+ "license": "CC-BY-4.0"+}
reviews/openreview/vw15ze9uyz/notes/tvkew46xnn.json added
+++ b/reviews/openreview/vw15ze9uyz/notes/tvkew46xnn.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "TVKEw46xNn",+ "replyTo": "Qk26wcTzlR",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for emphasizing these limitations. We agree that our previous response should distinguish between limitations of the current evaluation scope and a limitation specific to our inference procedure. \n\nRegarding data scope and orientation, the proposed algorithm follows the main quantitative protocol used by its direct predecessors, DiT-3D and TopoDiT-3D: category-wise evaluation on the Chair, Airplane, and Car subsets of the consistently aligned ShapeNet data. DiT-3D supports multi-class conditioning architecturally, although its released quantitative protocol trains a separate model for each category. TopoDiT-3D likewise reports category-wise main results. To compare with their results, we trained the proposed model using the same methodology, but the categorical scope is not an intrinsic limitation of this model lineage. We will add a section in the appendix for general-purpose generation. \n\nMoreover, all three methods employ an axis-aligned voxel representation and spatial positional embeddings. Consequently, their complete generation pipelines do not provide guaranteed invariance to arbitrary 3D rotations, and the reported experiments do not evaluate robustness on inconsistently oriented data. Therefore, this lineage of work using DiT for 3D point cloud generation shares the assumption of consistent orientation. HilbertGen’s HMC representation is also computed relative to the voxel coordinate system and does not introduce any new constraint to the previous setup. We will clarify the above in the final version of the paper. \n\nRegarding the inference process, we want to clarify that we do not directly access the training dataset during inference. The idea of the HMC provides multi-scale density and structural information rather than the full point coordinates. Before inference, we precompute a bank of HMC conditions from training-set point clouds. During generation, an HMC condition is randomly sampled from this fixed bank. We then sample an HMC token from the bank we generated during training. Compared with TopoDiT-3D, which conditions on the persistent diagram, which is a record of the birth and death of homological features during the generation process, we only require a coarse overview of the geometric structure, which explains the computational advantage of the proposed algorithm. During training, we construct a fixed bank of HMC conditions from the training set, and at inference time we randomly sample one condition from this bank. In our implementation, the entire bank-conditioned model contains 51.2M parameters, whereas the alternative VAE condition generator alone contains 59.6M parameters, comparable to the 60.0M-parameter TopoDiT-S/4 model. Thus, using the precomputed bank avoids introducing a VAE-sized auxiliary generator. Nevertheless, the bank is derived from the training set and must still be retained and deployed with the model, although the raw training point clouds are no longer accessed after its construction. We agree that this constitutes an additional inference-time requirement and will discuss it more explicitly in the revised paper. We agree that this constitutes an additional inference-time requirement. We will offer a more explicit discussion of the above in the final draft of the paper. \n\nWe hope the above explanations answer the reviewer’s questions and provide the necessary context. We will also make sure all the above are properly and explicitly addressed in revision. We thank the reviewer again for the detailed suggestions."+ },+ "createdAt": "2026-08-01T07:13:40.174Z",+ "modifiedAt": "2026-11-19T17:00:48.982Z",+ "url": "https://openreview.net/forum?id=VW15Ze9uYz¬eId=TVKEw46xNn",+ "license": "CC-BY-4.0"+}
reviews/openreview/vw15ze9uyz/notes/x7ed4jwktv.json added
+++ b/reviews/openreview/vw15ze9uyz/notes/x7ed4jwktv.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "X7ED4jwKTV",+ "replyTo": "D8jv5SlzLB",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Area Chair,\n\nThank you for identifying the decision-critical issues. We believe our rebuttal resolves the main methodological ambiguities.\n\nFirst, **inference uses no test shape or test-derived HMC condition.** The reported model samples from a fixed HMC bank precomputed exclusively from the training set. Importantly, constructing this bank is a simple offline preprocessing step and requires no additional training or auxiliary condition generator. We further provide a VAE-generated-HMC control, showing that learned condition generation is also possible.\n\nSecond, we agree that “topology-aware” was imprecise and will replace it with “structure-aware.” HMC captures multi-scale density and spatial organization rather than explicit homological invariants. We also explicitly state that the proposed algorithm follows the same setup of axis-aligned voxel representation, spatial positional embeddings, and category-wise ShapeNet protocol as the DiT-3D and TopoDiT-3D baselines, therefore introducing no additional assumptions.\n\nThird, we added the requested MMD evaluation. In particular, we note that the proposed algorithm consistently outperforms the newest benchmark, TopoDiT-3D, on all categories of data evaluated. We also clarified that the existing ablations isolate Hilbert-only and non-Hilbert voxel conditioning, supply complete hyperparameters with an explicit metric–cost selection rationale, and will revise the inference description, notation, and qualitative comparisons.\n\nThe central empirical evidence remains consistent: HilbertGen-3D improves generation metrics across five categories, each proposed component contributes, and the method reduces sampling time, training memory, and training time. \n\nWe again thank the Area Chair and all reviewers for their thoughtful comments, which have helped us substantially improve the clarity, positioning, and completeness of the paper."+ },+ "createdAt": "2026-08-04T04:31:39.116Z",+ "modifiedAt": "2026-11-19T17:00:48.983Z",+ "url": "https://openreview.net/forum?id=VW15Ze9uYz¬eId=X7ED4jwKTV",+ "license": "CC-BY-4.0"+}