potentialpaper

GRAPE: Graph-Augmented Prototype Explanations for Interactive Medical Image Diagnosis

Import NeurIPS 2026 submission lMhOWbjimZ: 8 notes

@openreview[bot] · 2026-11-22 17:59 UTC · f36df13bf9fc ·

Evidence

reviews/openreview/lmhowbjimz/forms.json added

+++ b/reviews/openreview/lmhowbjimz/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lmhowbjimz/notes/9ekp8idh17.json added

+++ b/reviews/openreview/lmhowbjimz/notes/9ekp8idh17.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "9ekP8idH17",
+ "replyTo": "uSVqEcgbWe",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Thank you for reading the appendix as closely as you did. All four of your weaknesses ask for evidence rather than disputing what we reported, so that is how we have treated them. Where things stand:\n\n- Already answerable from the submission: part of Q1, and the interference half of Q3.\n- Running now, results land tomorrow and go into this thread the moment they do: Q1 in full, then W1, then Q3 with Q4, in that order. Anything that slips we will say so rather than let it go quiet.\n- Not possible in this window, and we are not going to pretend otherwise: W3.\n\nThree of your five questions turn on numbers that do not exist yet, so if you are able, we would ask you to hold your assessment until tomorrow's results are up. We would rather be judged on them than on our description of them.\n\n**W1, the MLP against GAT comparison on NIH.** You are right that NIH is where this matters and right that it is missing. It is running now: parameter-matched 2-layer MLP on the flattened $K \\\\times M$ score vector against the GAT head, Stage 4 only with Stages 1-3 frozen, 5 seeds, official patient-level split, same protocol as Table 24.\n\nSince we would rather not be accused of deciding the interpretation after seeing the number, here it is beforehand. If the GAT beats the parameter-matched MLP by more than seed variance, we report the graph term as scaling with graph density, 4 edges at $K=3$ against 103 at $K=14$. If it does not, we narrow Module A to TBX11K and $K=3$ and say the graph term is not established at $K=14$. Table 3 already reports GRAPE and CSR as statistically comparable on NIH at $p = 0.894$, so we think the second outcome is at least as likely as the first.\n\nTwo things hold regardless. The TBX11K decomposition runs linear 0.798, MLP 0.865, GAT 0.896 (Table 24, Appendix S), so the nonlinear readout accounts for about 69% of the gain and graph structure for the +3.1 pp residual. And §4.3 L171-172 should not have claimed that co-occurrence structure is the key driver rather than the particular message-passing mechanism. Table 11 compares three graph heads against a linear one. All three are nonlinear, so it cannot separate graph from nonlinearity, and it does not license that sentence. We withdraw it. The camera-ready says instead:\n\n> All three graph heads perform within seed variance of one another (Table 11), so the choice of message-passing mechanism is not the driver. Graph structure is separated from nonlinear capacity by the parameter-matched MLP ablation (Table 24), which attributes +3.1 pp of the +9.8 pp linear-to-GAT gain on TBX11K to the graph term.\n\nWe should also have cross-referenced Table 24 from §4.3. The numbers sit there in prose with no pointer to the table, which is why the ablation was hard to find.\n\n**Q1, low false-positive operating points.** Some of this is already reported and we buried it. §4.5 notes that tightening the $U_k$ gate to $10^{-4}$ gives 12.6% FP at 78.0% TP on TBX11K, against the default of 16.4% FP at 85.1% TP. So the shape of the TBX11K curve is known, and at your 10% target the true-positive rate is somewhere below 78%. What we never produced is the 5% and 10% points themselves, or any low-FP analysis on NIH, where the global false-positive rate sits at $0.731 \\\\pm 0.011$ (Appendix Q). Both are inference-only sweeps over similarity maps we have already computed, so this is the first result we will post.\n\nOur expectation, again stated in advance. The NIH false-positive rate comes from dense concept overlap, not from a poor threshold choice: draw a correct box and one of the other 13 active concepts frequently has higher mean similarity inside it, with Pneumonia at 0.90 and Cardiomegaly at 0.85 (Appendix Q). We do not expect any single global threshold to reach 10% FP at a usable true-positive rate, and we expect per-concept thresholds to be necessary. If that is what we find, it goes in as a deployment constraint on $K > 3$ rather than as something we solved.\n\n**Q3 and Q4, what happens after a concept is added.** As things stand the evidence is localization and nothing else, so your reading is correct. Part of your question is settled by the protocol rather than by any experiment. In the leave-one-concept-out design of Appendix M we reinitialize only the held-out concept's $M=100$ prototypes and fine-tune those alone, with every other parameter frozen. The existing concepts' prototypes cannot move, so interference at the prototype layer is zero by construction. What can move is downstream: the GAT head sees a different score matrix and the co-occurrence graph gains a node.\n\nThat is what we are measuring on NIH. Adding Effusion at $n \\\\in \\\\{0, 1, 5, 20\\\\}$, we report macro-F1 on the 13 pre-existing concepts to test interference, macro-F1 and reliability-diagram calibration for Effusion itself, and any change in dominant-concept assignment inside annotated boxes for the concepts adjacent to it in the graph.\n\nThe claim gets narrowed either way. The Conclusion currently says Effusion at one shot exactly matches fully supervised Pointing Game accuracy, calling it 100% recovery. The number is right, 0.072 against 0.072 in Table 20, and the framing is misleading, because the fully supervised ceiling for Effusion is itself 0.072 and the one-shot result has zero standard deviation across three seeds. The camera-ready reads:\n\n> On NIH ChestX-ray14, one labeled Effusion image recovers the fully supervised Pointing Game accuracy for that concept (0.072, Table 20). This ceiling is low in absolute terms, and Module C is evaluated for localization only.\n\nTo answer Q4 head on: as submitted, Module C supports localization of prototype similarity maps, not reliable diagnosis with the new concept. We should not have implied otherwise.\n\n**W3, realistic clinician feedback.** We agree, and there is a sharper version of your point that we should make ourselves. Our motivation and our evaluation are not describing the same event. §1 motivates Module B through model confusion: the clinician draws a box, the model has a different concept dominant there, and applying the feedback amplifies the model's error. §4.5 then evaluates by corrupting the label instead. What the dominance rule actually detects is disagreement between the model's dominant concept and the claimed one. It is symmetric, it assigns no fault, and it fires whether the label is wrong or the model is. We corrupt labels because that is the direction we can control and count. The camera-ready reframes §4.5 as a controllable proxy for model-clinician disagreement rather than as a model of clinician error.\n\nNone of which answers what you asked, which is about ambiguous boxes, partial lesions, multi-finding regions and varying expertise. One step is available inside the window: re-running the check on geometrically perturbed boxes rather than relabeled ones, holding the claimed concept fixed while varying scale, centroid and lesion coverage. That gets at the sloppy-box condition and at our mean-aggregation choice (Table 23). It is still simulation, it cannot give us the deployment disagreement rate that determines whether 16.4% false positives is tolerable, and we will not dress it up as a user study.\n\n**Q5, distribution shift.** Partial evidence, no clean test, and the partial evidence is not reassuring. Table 5 shows macro-F1 moving by under 0.6 pp as the co-occurrence threshold sweeps from 0.01 to 0.30, across graphs ranging from dense to sparse, and Table 13 shows the sole cross-concept edge contributing 0.25 pp against 6.49 pp for the ActiveTB self-loop. At $K=3$ the model is nearly insensitive to edge structure, so prevalence shift has little to act on. The more relevant number is on NIH. Table 2, a 20k streaming shard at seed 42, puts GRAPE at 0.7138; Table 3, a 10k-patient stratified split over 5 seeds, puts it at $0.6031 \\\\pm 0.0174$. Sampling protocol, seed count and shard size all differ at once, so the comparison is confounded and we are not claiming it isolates case mix. We raise it because it is the closest thing in the paper to a change of sampling regime and the gap is large. The clean test is rebuilding the co-occurrence matrix under resampled prevalence and retraining Stage 4 alone. For now we would rather state the limitation than claim robustness we have not measured.\n\nOf your five questions, which one would most change your assessment? We have compute for about three of them before the window closes and would rather spend it where it counts."
+ },
+ "createdAt": "2026-07-27T21:21:33.022Z",
+ "modifiedAt": "2026-11-18T17:12:41.049Z",
+ "url": "https://openreview.net/forum?id=lMhOWbjimZ&noteId=9ekP8idH17",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lmhowbjimz/notes/gpnx5ydy2c.json added

+++ b/reviews/openreview/lmhowbjimz/notes/gpnx5ydy2c.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "GPNx5yDY2C",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer heNG",
+ "content": {
+ "summary": "The authors provide GRAPE, which is a framework for prototype-based framework for radiology, which could assist with clinical interpretability, building on top of existing CSR-based frameworks.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "The paper is clearly written, and although I am not the expert in the field, it was not hard to understand the story. Being able to add additional concepts at the inference time seems to be a welcome addition, which the existing closed-set vocabulary might not be able to cover. The comprehensive ablation experiments confirms that each of the module benefits the downstream performance.\n\nFor someone who does not work in radiology (but pathology), I am concerned that the work is based with Resnet50 backbone, not an in-domain foundation models. Will the conclusions change if GRAPE is tested with different backbone models?",
+ "quality": 3,
+ "clarity": 4,
+ "significance": 3,
+ "originality": 3,
+ "questions": "For prototype interaction, would testing out Tansformer-based self-attention provide benefits over GNN, which requires pre-defined adjacency matrices? The number of prototypes do not seem to be large and there are enough X-ray images in the training dataset, so Transformer training wouldn't overfit.",
+ "limitations": "yes",
+ "rating": 5,
+ "confidence": 1,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No concerns",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "Thank you for your response - I would really like to see the backbone comparison in the camera-ready version. I will maintain my score."
+ },
+ "createdAt": "2026-06-25T13:48:33.539Z",
+ "modifiedAt": "2026-11-18T13:37:06.149Z",
+ "url": "https://openreview.net/forum?id=lMhOWbjimZ&noteId=GPNx5yDY2C",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lmhowbjimz/notes/hgkoxte8mg.json added

+++ b/reviews/openreview/lmhowbjimz/notes/hgkoxte8mg.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "HgkoXTe8mg",
+ "replyTo": "GPNx5yDY2C",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "You raise two questions, both really asking whether Module A's design choices are doing any work. The second one we can answer from what is already in the paper. On the first we would rather tell you plainly what we will and will not do this week.\n\n**On a Transformer head instead of the GNN.** Your reasoning about capacity is right. At $K=3$ the score matrix is only $3 \\\\times 100$, so a self-attention head over concept nodes has plenty of data and no real overfitting risk. We think the paper answers the question already, but in two pieces that we never put next to each other.\n\nAppendix F swaps the GAT for ML-GCN and ADD-GCN under the same protocol, Stage 4 only, Stages 1-3 frozen. All three land within seed variance of one another, macro-F1 between 0.859 and 0.898, and all three sit well clear of the linear head. So whichever message-passing scheme you pick is not what produces the gain. Appendix S then separates capacity from structure inside a single protocol: linear 0.798, parameter-matched MLP 0.865, GAT 0.896. The MLP has no graph at all and still closes roughly 69% of the linear-to-GAT gap, which leaves about +3.1 pp for the co-occurrence structure.\n\nPut those together and the picture is that the prototype-score matrix mostly wants a nonlinear readout, with the relational part contributing a small residual. Self-attention is a relational nonlinear readout without a predefined adjacency, so we would expect it to land in the same band, above the MLP and near the GAT. It would also be a cleaner control than anything we ran, since it drops the adjacency while keeping the relational structure. We are adding it to the camera-ready.\n\n**On the backbone.** We have not tried an in-domain foundation model, and you are right that this is the test a pathology or radiology reader would want. We are not going to run it in a one-week window and then report a single seed as though it settled anything, so it goes to the camera-ready alongside the self-attention head. Our compute this week is committed to the two experiments that Reviewers zmQt and abSb flagged as blocking.\n\nWhat the paper supports meanwhile is narrower than what you asked. Module A works on the $K \\\\times M$ matrix of prototype similarity scores, not on backbone features, so swapping the backbone changes the quality of the scores it receives rather than what it does with them. The same holds for Modules B and C, which are defined over similarity maps. The number we would expect to move is the absolute Pointing Game score, which §5 attributes to the $7 \\\\times 7$ resolution of ResNet-50 feature maps rather than to the prototype layer, so a backbone with finer spatial output ought to raise it. That is a prediction and not a result, and we are not asking you to treat it as one.\n\nIf the backbone comparison is what decides your assessment, rather than something you would be content to see in the camera-ready, say so and we will rethink how we are spending the week."
+ },
+ "createdAt": "2026-07-27T21:19:12.794Z",
+ "modifiedAt": "2026-11-18T17:12:40.442Z",
+ "url": "https://openreview.net/forum?id=lMhOWbjimZ&noteId=HgkoXTe8mg",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lmhowbjimz/notes/nnnattmcfw.json added

+++ b/reviews/openreview/lmhowbjimz/notes/nnnattmcfw.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "nnnATtmcfw",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer zmQt",
+ "content": {
+ "summary": "The paper builds upon the concept-based similarity reasoning (CSR) [8] with three additions. \n\n1) The authors add a graph attention module replacing CSR's linear prediction head.\n\n2) The authors add a concept-mismatch safety check module, which computes the mean and variance of the class concepts in a patch. The authors claim that the mean of class concept activations can be used to warn doctors who think the patch has a concept k* that is different from the dominant concept $k^\\dagger$ currently inferred by the model. The model will seek the doctor's confirmation before proceeding with accepting the doctor's concept annotation.\n\n3) The authors add an open-vocabulary prototype anchoring module, which promotes the prototype embedding and concept text embedding similarity, where the text embedding is provided by a BioViL-T frozen encoder. This allows new text concepts to be mapped in the prototype space and, therefore, allows a zero-shot prototype determination from new texts.\n\nA four-stage training pipeline is used to train this model.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Quality\n\nThe submission is complete in terms of proposing a complete method, although I think the experiment is very difficult to go through. The experiments feel patchy as they went through many reviews, and a lot of experiments were added. The authors should try to reorganise the experiments (as well as the entire paper flow) to be more directly accessible. Also, please make sure the experiments directly verify the contributions; it unfortunately feels all over the place in the current status. \n\n1. The first claim is that GAT is better than the CSP baseline's linear head. The utility of GAT is primarily assessed by the Macro F1 and PG performances over CSR. The author showed that the GAT with message passing produces a better performance in Table 1. Two additional GNNs, ML-GCN and ADD-GCN, are compared in Appendix F, which suggests the two other forms of GCN work out similarly levels of gain. Then, going back to Sec 4.3, it states in L178 \"a generic nonlinear function of the same capacity\" achieves similar performance, and concludes the co-occurrence graph structure is only 3.1% better than the nonlinear function. Such a \"nonlinear function of the same capacity\" comparison is not included in any of the Tables, but it should. Also, this suggests the main improvement comes from introducing a parameter layer that finetunes the model post-similarity score computation instead of adding a GNN. That is common knowledge. I think the community would be interested in how much the \"graph\" actually helps or does it.\n\n2. Safety check evaluation in Sec 4.5. I'm not sure how to interpret the real-world importance of this functionality, as this experiment is designed to artificially generate an incorrect concept. In reality, I don't think this would have ever happened, for this safety checking function to be meaningful, so whether those evaluation results hold practical meaning is hard to judge. A human study would allow better insights. I fail to understand how MC-Dropout is suddenly relevant and should be evaluated, so as the uncertainty, I don't think the paper's contribution or methodology sections are properly connected to the uncertainty part. There are a couple of mentions of uncertainty in the Appendix, but the Appendix should not contain critical information, as NeurIPS suggests reviewers do not have to read the Appendix. Similarly, many parts of the methodology went to the Appendix, which is not ideal.\n\n3. The zero-shot concept addition is verified using a leave-one-out manner, which is understandable, but I find it hard to appreciate the practicality of experiment design and the outcome in Tables 19 and 20. It is a standard zero-shot type of evaluation, but it is only evaluating the proposed method itself; there is no comparison to the CSR baseline or other methods. Regarding the faithfulness evaluation, on the other hand, I'm not sure how the Insertion and Deletion AUC is tied to faithfulness. The original paper [17] has no such claim that it evaluates faithfulness. The authors should consider properly defining what they mean by faithful first.\n\nClarity \n\nI appreciate that the paper includes a notation table, which helps figure out what's what. The writing, in terms of sentences and grammer are sensible. The math equations appear to be properly written.\n\nThere are several issues with the structuring.\n\n1. It is obvious that the paper shelves significant sections into the Appendix to obey the page limit, but it significantly impacts the readability of the paper; the constant scrolling is tiring. \n2. The intro and related works are significantly shorter than the field norm, which does not properly motivate the topic and discuss the literature. \n3. Experiments are not well designed and not properly discussed. The result sections merely report the numbers but fall short of explaining the results. If space is an issue, I'd remove the textual reporting of the numbers, but focus more on how those comparisons support the claim. \n4. There are more pages of the Appendix than the main paper. I'd suggest that the authors spend some time making sense of the paper structure.\n \nSignificance and Originality\n\nThe submission proposes several improvements over the CSR method. In my opinion, each of them is not a novel addition, and hence the significance of the paper is limited.\n\n1. The paper's first contribution in terms of introducing graph neural nets is not new, and as aforementioned, its usefulness is not properly demonstrated.\n\n2. The concept-mismatch safety check. I appreciate that the check can be enabled in a software implementation, should such a system be used in real-world clinical scenarios, but it feels more like a trivial implementational addition rather than a research contribution. I think the model could predict a concept in a doctor-annotated region as well. If so, shouldn't that prediction be sufficient to compare with the doctor-annotated concept to support such a check?\n\n3. CLIP-like vision and language embeddings alignment for arbitrary texts to align with a vision embedding or vice versa has been quite heavily explored.",
+ "quality": 2,
+ "clarity": 2,
+ "significance": 2,
+ "originality": 2,
+ "questions": "I have discussed the major issues of the paper in the strengths and weaknesses section. Some other questions:\n\n1. In Eq. 9, why is the perturbation needed?\n\n2. Which module used $A_{kk'}$ and how?\n\n3. In Figure 1, please align the blocks and symbols with their counterparts in the paper. E.g, G was not introduced in Sec 3.2, Var. is perhaps the inline equation in L105? $\\bar{s}_k$ does not look like a variance but a mean according to Eq.6 and 4.\n\n4. Why does Table 17 have no TP for p=0, and FP for p > 0?",
+ "limitations": "yes",
+ "rating": 2,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No formatting concerns.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I appreciate the authors' responses. However, substantial issues remain regarding the writing and structure, overclaiming, and methodological completeness. The novelty also remains limited and unconvincing. Taken together, these concerns would require substantial revision to the paper; therefore, I remain confident in my initial rating."
+ },
+ "createdAt": "2026-06-18T12:20:23.088Z",
+ "modifiedAt": "2026-11-18T13:37:07.530Z",
+ "url": "https://openreview.net/forum?id=lMhOWbjimZ&noteId=nnnATtmcfw",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lmhowbjimz/notes/o3c8n8dzut.json added

+++ b/reviews/openreview/lmhowbjimz/notes/o3c8n8dzut.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "o3C8N8dzut",
+ "replyTo": "nnnATtmcfw",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Four of your points identify genuine errors in the paper. We accept all four and take them first. On Quality and Clarity we give a concrete mapping rather than a promise to reorganize. On Originality we state where we stand and leave it there.\n\nOn timing: the runs below are executing now and the results land tomorrow. We will post them in this thread the moment they do. Three points below turn on numbers that do not exist yet, so if you are able, please hold your assessment until you have seen them. If anything slips we will say so rather than let it go quiet.\n\n**1. The nonlinear-capacity comparison.** It does exist, in Appendix S, Table 24: linear 0.798 at 903 parameters, MLP 0.865 at 47,235, GAT 0.896 at 43,587, identical Stage 1-3 weights, same Stage 4 protocol. §4.3 L177-180 gives those numbers in prose and never points at the table. That is our failure and why you could not find it.\n\nYour inference is also right, and worse, the paper contradicts itself. §4.3 L171-172 concludes from Table 11 that co-occurrence structure is the key driver rather than the particular message-passing mechanism. But Table 11 compares GAT, ML-GCN and ADD-GCN against a linear head, and all three are nonlinear, so it cannot separate graph from nonlinearity. We withdraw the sentence. What survives is your reading: the nonlinear readout gives roughly 69% of the linear-to-GAT gain and the graph the remaining +3.1 pp. Appendix G agrees, the sole cross-concept edge being worth 0.25 pp against 6.49 pp for the ActiveTB self-loop, so at $K=3$ the graph is mostly self-aggregation.\n\nYou asked how much the graph actually helps. At $K=3$, +3.1 pp. At $K=14$ we do not know, and Reviewer abSb asked the same. The parameter-matched MLP against GAT on NIH is running now, 5 seeds, official patient-level split, and we fix the reading in advance: if the GAT does not clear the MLP by more than seed variance, we narrow Module A to TBX11K and $K=3$. Table 3 already reports GRAPE and CSR as comparable on NIH at $p = 0.894$, so that outcome is at least as likely. Modules B and C do not depend on Module A, Module B being inference-only per the Table 1 footnote, so the narrowing stops there.\n\n**2. Insertion and Deletion AUC, and the word faithfulness.** You are right, and we overclaimed. Table 21's own caption says the differences fall well within one standard deviation and indicate comparable faithfulness rather than a clear advantage for either method. The Conclusion then says the evaluation confirms that prototype similarity maps capture genuinely predictive spatial regions. That does not follow from the table it rests on, so we cut it. The camera-ready reports:\n\n> Insertion and Deletion AUC for GRAPE ($0.886 \\\\pm 0.148$ and $0.954 \\\\pm 0.068$) and CSR ($0.873 \\\\pm 0.138$ and $0.923 \\\\pm 0.104$) differ by less than one standard deviation on the 200-image TBX11K test split. We report them as comparable attribution behavior, not as an advantage for GRAPE.\n\nOn the term itself, you are right that we never defined it. Reference [17] introduces these as causal deletion and insertion measures. The camera-ready drops the word from §4.6 and the Conclusion and says what is measured instead: how quickly predicted class probability changes as pixels ranked by saliency are removed or revealed. We have no definition of faithfulness we could defend, so we have stopped asserting one.\n\n**3. Whether the safety-check scenario is real.** Where you are closest to right, and where our writing misled you.\n\nOur motivation and our evaluation are not describing the same event. §1 motivates Module B through model confusion: the clinician draws a box, the model has a different concept dominant there, and the feedback amplifies the model's error. §4.5 then evaluates by corrupting the label instead. You read the evaluation and reasonably asked when a clinician would do that. Mostly they would not, and the evaluation is not really about clinician error.\n\nWhat the dominance rule detects is disagreement between the model's dominant concept and the claimed one. It is symmetric and assigns no fault: it fires whether the label is wrong or the model is. We corrupt labels because that is the direction we can control and count. The camera-ready reframes §4.5 as a controllable proxy for model-clinician disagreement.\n\nThat does not make a user study unnecessary. It cannot give the deployment disagreement rate, which determines whether 16.4% false positives is tolerable at all, and only clinicians can supply that. We cannot run it in this window and will not pretend otherwise.\n\n**4. Figure 1 mislabels the safety-check signal.** Correct, and it is the mean. The check uses $\\\\mu_k$ from Eq. 4, aggregated to $\\\\bar{s}_k(B)$ in Eq. 6. The variance $U_k$ in Eq. 5 does training-time prototype masking and acts as the FP-suppression gate in §4.5, never entering the dominance rule, so the block labeled Var and its threshold arrow are both wrong. The corrected block reads: mean similarity inside box $B$, warn if the dominant concept differs from the claimed one by more than the gap threshold. Related, and also ours: the notation table gives two different thresholds the same 0.05 default in similar glyphs, so we are renaming the second. And $G$ appears in Figure 1 and §3.5 without being introduced in §3.2, which defines $A$ and never names the graph.\n\n**5. Why uncertainty and MC-Dropout appear at all.** Your objection is sharper than we gave it credit for, and answering it simplifies the paper. Module B's dominance rule does not use uncertainty. It compares $\\\\bar{s}_k(B)$ across concepts, and that is uncertainty-free. $U_k$ is an optional gate trading true positives for false positives, 85.1% TP at 16.4% FP with it against 88-89% at 21.7% without, and MC-Dropout is a baseline for the gate rather than for Module B. The paper never says this, which is why the uncertainty material reads as bolted on. The camera-ready states it in §3.3 and demotes the MC-Dropout comparison to an ablation of the gate.\n\n**6. Module C is only ever evaluated against itself.** Correct, though the missing control is not the one you named. CSR cannot add a concept at test time at all, its vocabulary being closed, which is the limitation Module C exists to remove, so there is no CSR number to compare against. We should have written that rather than leave the absence unexplained. The paper does compare against full supervision for the same concept.\n\nThe control genuinely missing is a random anchor: reinitialize the held-out concept's prototypes from a random unit vector rather than the BioViL-T embedding, matched on seeds and $n$. Without it we have no evidence the text anchor contributes anything. There is an accidental data point against us in the paper that we should have flagged: Appendix M notes obsolete_tb's $n=0$ value of 0.093 reflects random initialization, higher than active_tb's text-anchored 0.030. Different concepts, so it proves nothing, but it points the wrong way and we left it in a caveat. The matched control is queued with the NIH ablation.\n\n**7. Table 17.** It reports FP only at $p=0$ and TP only at $p > 0$. The by-construction argument in the caption covers $p=0$ and $p=1$ and not the intermediate values, where both quantities plainly exist. We measured FP at $p=0$ because every correction there is correct, which is the cleanest estimator, but both belong at every $p$. Re-tabulated and posted here.\n\n**8. Eq. 9, and which module uses $U_k$.** Without the perturbation all $M$ prototypes of a new concept initialize identically, take identical gradients under Eq. 10, and the layer collapses to one prototype. The 0.1 noise scale breaks that, and it belongs in §3.4. $U_k$ masks prototypes in Stage 3 (Appendix K), gates false positives in §4.5, and is benchmarked against MC-Dropout in Appendix O. If you meant another symbol, tell us which.\n\n**9. Experiments not verifying the contributions.** Your Quality objection, and the one we think is genuinely fixable. The mapping we should have written:\n\n- Module A beyond a nonlinear readout: Table 24 at $K=3$, plus the NIH run above. Table 11 answers a different question, which head to use, and will be labeled that way.\n- Module B detects disagreement: Tables 17, 6, 23, 22, and Appendix Q for NIH.\n- Module C adds a concept without retraining: Tables 19 and 20, localization only, plus the random-anchor control.\n- Latency: Table 12.\n\nEverything else is supporting or negative and will be labeled so. Three tables carry conclusions their own numbers do not support, and all three are withdrawn above.\n\n**10. Structure and length.** Accepted without argument. Revision rules bar a new PDF, so all we can offer is the plan: Table 24 into §4.3; the NIH Module B result into §4.5, since a false-positive rate of 0.731 belongs in the main text; Appendix K's equations and the masking rule into §3.2 and §3.3; Related Work expanded.\n\n**11. Novelty.** Briefly, because we cannot argue you out of a judgment. GNNs for co-occurrence and CLIP-style alignment are prior art and we claim neither. On the safety check you are right that the mechanism is simple. What we offer is its calibration and its failure regime, not the idea.\n\n**12. One thing we flag ourselves.** The TBX11K linear and CSR macro-F1 shows up as 0.706 in Table 1, 0.728 in Table 3, 0.7519 in Table 11 and 0.798 in Table 24, and Pointing Game varies similarly across Tables 1, 3, 11, 18 and 24. The abstract's 2.6x figure draws on the same set. Each has a protocol reason and none is stated where the number appears. We are auditing every table against its source run and will post a reconciliation here. Where a number is wrong rather than differently measured, we will say so.\n\nWhich of points 1 to 10 remain blocking? And if your assessment rests on point 11 regardless of the rest, we would rather know now than spend the window on experiments that will not move it."
+ },
+ "createdAt": "2026-07-27T21:22:39.478Z",
+ "modifiedAt": "2026-11-18T17:12:40.432Z",
+ "url": "https://openreview.net/forum?id=lMhOWbjimZ&noteId=o3C8N8dzut",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lmhowbjimz/notes/tpid40dr0y.json added

+++ b/reviews/openreview/lmhowbjimz/notes/tpid40dr0y.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "TPid40dR0y",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "The paper introduces GRAPE, a prototype-based framework for interactive medical image diagnosis that integrates a graph attention head for concept co-occurrence, a concept-mismatch safety check, and open-vocabulary prototype anchoring.\nStrengths include its focus on clinical workflow safety, transparent multi-seed reporting (positive and null results), and the ability to incorporate new text concepts zero-shot.\nWeaknesses include non-linear capacity accounting for most GAT gains over graph structure, safety check evaluations using artificial feedback rather than real clinician testing, and methodological details relegated to the appendix.\nWith reviewer scores at 5 (Reviewer heNG), 2 (Reviewer zmQt), and 4 (Reviewer abSb), I recommend acceptance (poster) because the clinical motivation and empirical foundation outweigh the weaknesses.",
+ "final_justification": "I have reviewed the authors' response and the post-rebuttal discussion. While one reviewer maintained rejection with confidence citing overclaimed contributions and presentation issues, the other two reviewers supported acceptance. They noted that the newly provided ablations and low-false-positive operating point sweeps adequately addressed the main technical concerns. Therefore, the final recommendation is to accept this paper as a poster."
+ },
+ "createdAt": "2026-09-24T11:18:15.260Z",
+ "modifiedAt": "2026-11-18T14:53:33.362Z",
+ "url": "https://openreview.net/forum?id=lMhOWbjimZ&noteId=TPid40dR0y",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lmhowbjimz/notes/usvqecgbwe.json added

+++ b/reviews/openreview/lmhowbjimz/notes/usvqecgbwe.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "uSVqEcgbWe",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer abSb",
+ "content": {
+ "summary": "This paper proposes GRAPE, a prototype-based framework for interactive medical image diagnosis. It extends a CSR-style prototype classifier with three modules: a graph attention task head over empirical concept co-occurrence statistics, a concept-mismatch safety check for clinician-drawn bounding boxes, and text-anchored prototype initialization using BioViL-T for adding new concepts. The method is evaluated on TBX11K and NIH ChestX-ray14 using classification Macro F1, Pointing Game localization, simulated feedback-safety checks, zero/few-shot concept addition, latency, and insertion/deletion faithfulness metrics.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths\n- The authors address the central challenge of making prototype-based medical image classifiers safer and more usable in interactive clinical workflows. The most interesting contribution is the concept-mismatch safety check, which warns when the model’s dominant concept inside a clinician-provided region conflicts with the intended concept label. This is a clinically meaningful failure mode that is not usually addressed in prototype-based medical image classifiers.\n- The paper reports multi-seed means, p-values, null results, bootstrap confidence intervals, latency, ablations, and limitations. This is a major strength.\n- Weak or null results are also reported; the authors clearly disclose that the NIH classification result does not improve over CSR and that the multi-seed Pointing Game comparison against CSR is not significant. Failure cases are really informative for this type of applications.\n\nWeaknesses\n- The paper provides a useful parameter-matched MLP ablation on TBX11K showing that added nonlinearity explains much of the Linear-to-GAT improvement, while graph structure explains a smaller residual gain. However, the same MLP-vs-GAT ablation is not reported on NIH, where the graph is richer and graph reasoning should matter more. This makes it difficult to assess whether the graph component is genuinely useful beyond nonlinear readout capacity in the setting where graph structure is most relevant.\n- Module B includes threshold and gating analyses, but it is not evaluated at very low clinically realistic false-positive targets such as 5% or 10%. This is particularly important for a clinician-facing warning system. The paper reports that the NIH false-positive rate is very high and states that learned or per-concept thresholds would be needed for K>3 settings. What remains unanswered is whether the method can maintain useful true-positive detection at low false-positive operating points.\n- The safety-check evaluation is based on simulated wrong-concept reassignment of existing bounding boxes. The paper acknowledges the absence of human-user validation, but it does not answer whether the mechanism works under realistic clinician feedback patterns, including ambiguous boxes, partial lesions, multi-finding regions, or corrections drawn by users with different levels of expertise.\n- Module C is evaluated mainly through zero/few-shot Pointing Game localization. The paper does not clearly answer what happens to downstream diagnostic classification, calibration, or competition with existing concepts after a new concept is added. It remains unclear whether the new concept is integrated as a reliable diagnostic output or whether the evidence is limited mainly to localization behavior.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "- Can Module B be evaluated at low clinically realistic false-positive targets, for example 5% or 10%, especially on NIH? What true-positive rate remains at those operating points?\n- Can the authors validate Module B with a more realistic clinician-feedback simulation or a small user study, rather than wrong-concept reassignment of existing boxes?\n- When a new concept is added through Module C, what happens to downstream classification calibration, decision thresholds, and competition with existing concepts?\n- Does Module C support reliable diagnosis with the newly added concept, or only localization of prototype similarity maps?\n- How robust is the static training-label co-occurrence graph to distribution shift in disease prevalence, institutional case mix, or label co-occurrence patterns?",
+ "limitations": "yes",
+ "rating": 4,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No formatting issues were noticed.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "Overall, the rebuttal substantially improves the evidence base. At the same time, the new results support narrower claims: graph-specific benefit is not established on NIH under the current evaluation; Module B loses substantial sensitivity at the tested low false-positive operating points; Module C can affect classification, calibration, and dominant-concept assignments; and reliable diagnosis with a newly added concept has not been demonstrated. The Module C localization results also require numerical reconciliation with the submitted values. Realistic interaction validation and robustness of the graph under distribution shift remain open. Considering the additional evidence and the authors’ proposed narrowing of the claims, I remain inclined toward borderline accept."
+ },
+ "createdAt": "2026-06-18T10:05:59.727Z",
+ "modifiedAt": "2026-11-18T13:37:09.162Z",
+ "url": "https://openreview.net/forum?id=lMhOWbjimZ&noteId=uSVqEcgbWe",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lmhowbjimz/notes/zzujsgon5g.json added

+++ b/reviews/openreview/lmhowbjimz/notes/zzujsgon5g.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "ZzuJsGoN5G",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair 6H7i",
+ "content": {
+ "metareview": "The paper introduces GRAPE, a prototype-based framework for interactive medical image diagnosis that integrates a graph attention head for concept co-occurrence, a concept-mismatch safety check, and open-vocabulary prototype anchoring.\nStrengths include its focus on clinical workflow safety, transparent multi-seed reporting (positive and null results), and the ability to incorporate new text concepts zero-shot.\nWeaknesses include non-linear capacity accounting for most GAT gains over graph structure, safety check evaluations using artificial feedback rather than real clinician testing, and methodological details relegated to the appendix.\nWith reviewer scores at 5 (Reviewer heNG), 2 (Reviewer zmQt), and 4 (Reviewer abSb), I recommend acceptance (poster) because the clinical motivation and empirical foundation outweigh the weaknesses."
+ },
+ "createdAt": "2026-07-25T01:14:25.018Z",
+ "modifiedAt": "2026-11-18T15:19:46.719Z",
+ "url": "https://openreview.net/forum?id=lMhOWbjimZ&noteId=ZzuJsGoN5G",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lmhowbjimz/submission.json added

+++ b/reviews/openreview/lmhowbjimz/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "lMhOWbjimZ",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 8198,
+ "url": "https://openreview.net/forum?id=lMhOWbjimZ",
+ "license": "CC-BY-4.0"
+}

versions/v_8z5rfqbc.json added

+++ b/versions/v_8z5rfqbc.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-04-29",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 8198,
+ "url": "https://openreview.net/forum?id=lMhOWbjimZ",
+ "reviews": "openreview/lmhowbjimz",
+ "evidence": [
+ "https://openreview.net/forum?id=lMhOWbjimZ"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=lMhOWbjimZ",
+ "evidence": [
+ "https://openreview.net/forum?id=lMhOWbjimZ"
+ ]
+}