SurgReasoner: Surgical Reasoning Segmentation with Dynamic Difficulty-Aware Reinforcement Learning
Import NeurIPS 2026 submission 3S2PCXYUIS: 10 notes
@openreview[bot] · 2026-11-22 17:54 UTC · 21856c432ad7
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,22 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "3S2PCXYUIS"+ }+ ],+ "title": "SurgReasoner: Surgical Reasoning Segmentation with Dynamic Difficulty-Aware Reinforcement Learning",+ "authors": [+ "Dong Zhang",+ "Cheng Xue"+ ],+ "abstract": "Surgical reasoning segmentation requires a model to infer the target instrument or anatomical structure from an implicit clinical query and produce a pixel-level mask. This setting is far more challenging than category-level surgical segmentation, as targets are specified by functional role, spatial relation, or anatomical interaction rather than explicit class names. It also exposes a key limitation of existing reinforcement learning-based visual grounding methods: standard reward normalization tends to under-optimize clinically important hard samples, such as small instruments, occluded organs, and ambiguous targets. To address this, we introduce SurgSeg-14K, a surgical reasoning segmentation benchmark with over 14K image-mask pairs across seven surgical scenarios and 30 fine-grained categories. Each sample links an implicit clinical query to a binary mask, spatial annotations, and a reasoning trajectory. We further propose SurgReasoner, which decomposes the task into two stages: clinical query interpretation for spatial prompt generation, and prompt-based mask generation with a frozen segmentation model. To improve reinforcement learning for spatial reasoning, we introduce a dynamic difficulty-aware reweighting strategy that combines intrinsic target difficulty with rollout correctness, enabling training to focus on challenging targets. Experiments on SurgSeg-14K show that SurgReasoner outperforms the strongest grounding baseline by large margins, with consistent gains especially on hard samples, suggesting a practical path toward reasoning-driven surgical visual perception.",+ "year": 2026,+ "venue": "NeurIPS 2026",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/3s2pcxyuis/forms.json added
+++ b/reviews/openreview/3s2pcxyuis/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/5yx0zbshke.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/5yx0zbshke.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "5yx0ZBSHke",+ "replyTo": "T3oDPhWeX7",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Many thanks for your valuable comments and questions, which greatly help us improve this work. We address your questions as follows.\n\nQ1. Relationship to referring segmentation. How does the proposed task fundamentally differ from existing referring image segmentation or reasoning segmentation settings? Why are comparisons against established referring segmentation methods absent?\n\nA1. We have discussed this distinction in our related work. We clarify that the implicit reasoning queries in our work target future interactive surgical AI systems, rather than compensating for surgeons’ lack of anatomical knowledge. They represent latent surgical intent that guides models to identify clinically relevant entities under specific operative contexts. Unlike traditional segmentation with predefined categories, our task requires models to infer the target based on procedural goals and contextual understanding.\n\nExisting surgical segmentation methods mainly focus on fixed anatomical structures or instruments, while general-purpose MLLMs lack precise pixel-level grounding for open-ended clinical queries. For example, the query “What tissue structure must be gently displaced or avoided in this step?” does not explicitly name the target; the model must understand the surgical context and infer that the liver is relevant because it may obstruct exposure of the esophagogastric junction.\n\nWe introduce clinically grounded reasoning traces that bridge surgical intent with pixel-level localization, enabling models to infer what to segment and why before generating the mask. This advances surgical segmentation from static recognition toward intent-driven surgical scene understanding. Regarding comparisons with referring segmentation methods: SAM4MLLM in Table 2 is a representative RS method. Since referring segmentation methods are inherently designed for explicit queries rather than implicit reasoning, direct comparison on our task is of limited reference value. Nevertheless, we supplemented our evaluation with additional RS baselines, as shown in the table below. SurgReasoner consistently outperforms all RS-based methods across all metrics.\n\n| Method | IoU % | pDice % | Dice % |\n|--------|-------|---------|--------|\n| LISA-7B-LLaVA1.5 | — | — | 24.56 |\n| LISA-13B-LLaVA1.5 | — | — | 27.83 |\n| SAM4MLLM-8B | 13.60 | — | 12.45 |\n| SurgReasoner | 44.22 | 11.66 | 44.78 |\n\n\nQ2. Can the authors provide concrete surgical scenarios where clinicians naturally use implicit descriptions instead of directly naming instruments?\n\nA2. We appreciate the reviewer’s comment. Our task is related to referring segmentation (RS) but differs in the nature of the query. Existing RS methods typically assume that the target entity is explicitly described (e.g., “segment the liver”), while our task introduces implicit surgical intent queries, where the target must be inferred from procedural goals and surgical context before localization.\n\nFor example, the query “What tissue structure must be gently displaced or avoided in this step?” does not directly specify the target anatomy. The model must understand the operative context and infer that the liver is relevant because it may obstruct exposure of the esophagogastric junction. Therefore, our task requires reasoning about which entity is clinically relevant and why, beyond conventional language grounding.\n\nWe introduce clinically grounded reasoning trajectories that bridge surgical intent with pixel-level localization, advancing surgical segmentation toward intent-driven surgical scene understanding. We agree that RS methods are important baselines and have supplemented comparisons with representative RS approaches, including LISA-7B-LLaVA1.5, LISA-13B-LLaVA1.5, and SAM4MLLM-8B, under the same evaluation protocol. SurgReasoner consistently outperforms these methods, demonstrating the benefit of surgical intent reasoning.\n\n\nQ3. RL generalization. Would the proposed dynamic difficulty-aware reweighting strategy still provide gains on existing referring segmentation or grounding benchmarks outside SurgSeg-14K?\n\nA3. To verify generalization beyond SurgSeg-14K, we evaluate on ReasonSeg, a standard reasoning segmentation benchmark. Models are trained on RefCOCOg and zero-shot evaluated on ReasonSeg-val. Our difficulty-aware reweighting consistently improves over standard GRPO, confirming general gains beyond the surgical domain.\n\n| Method | ReasonSeg/IoU |\n|--------|---------------|\n| SFT | 52.6 |\n| GRPO | 61.9 |\n| Ours | 65.1 |\n\n\nQ4. Only a subset of generated samples is reviewed by experts. What percentage of the dataset was manually inspected? What was the observed error rate?\n\nA4. We appreciate the request for more details. SurgSeg-14K contains approximately 14,000 instances. We conducted a 50% stratified sample review (7,000 instances) as a first-pass by 8 medically trained student reviewers, evaluating query plausibility, target uniqueness, and mask-rationale consistency. Borderline/uncertain cases (e.g., ambiguous functional states, multiple similar instruments) were escalated to 3 clinical experts for secondary review and final decision-making. Across the reviewed subset, approximately 10-15% of samples required text-only corrections (e.g., clarifying spatial references), and approximately 3-5% were rejected/removed due to unrecoverable inconsistencies. We will add these detailed statistics, inter-reviewer disagreement resolution criteria, and examples of corrected/rejected cases to Appendix A.\n\n\nQ5. Dataset licensing and release. The benchmark combines multiple public datasets and one private dataset. Are redistribution rights available for all source datasets? Will the benchmark be fully released? If the private dataset cannot be released, how will reproducibility be ensured?\n\nA5. We are committed to open science and plan to fully release all associated resources upon publication. Specifically, we will release via GitHub and Hugging Face Datasets: images from all public source datasets (where licenses permit), binary masks, implicit queries, reasoning trajectories, derived spatial prompts, and all construction and evaluation code. We also plan to release the annotations (queries, reasoning trajectories, and masks) for the private clinical subset under a data use agreement. In addition, model weights trained on the full SurgSeg-14K and the corresponding training code will be made publicly available to ensure full reproducibility.\n\n\nQ6. Why are two points required? One point appears related to the centroid. What is the semantic role of the second point? Was a single-point formulation evaluated?\n\nA6. This two-point design is motivated by empirical observation. We validated this with preliminary SAM2 experiments prior to finalizing the design — two-point prompting consistently outperformed single-point prompting in segmentation quality, confirming that broader spatial coverage leads to more accurate and complete mask prediction.\n\n| Method | IoU % | pDice % | Dice % |\n|--------|-------|---------|--------|\n| bbox+point | 43.97 | — | 44.32 |\n| bbox+points | 44.22 | 11.66 | 44.78 |\n\n\nQ7. How sensitive are results to $\\lambda_f$, $\\lambda_s$, $\\lambda_{iou}$, $\\lambda_{edge}$, $\\lambda_{pdice}$, and $\\lambda_{distance}$? Could a simpler reward achieve similar performance?\n\nA7. The reward function formulation is not the core contribution of this work — we directly adapt standard segmentation metrics as reward signals with task-specific adjustments. The core contribution of this paper is the Dynamic Difficulty-Aware Advantage Reweighting strategy, not the design of reward weights. We select six reward components to evaluate segmentation quality from multiple complementary dimensions: reasoning capability (Format), region overlap (IoU/Dice), pixel-level accuracy (Focal), boundary quality (Edge), and spatial consistency (Distance). Since each component captures a distinct and equally important aspect of segmentation quality with no natural priority ordering among them, we assign uniform weights:\n$\\lambda_f = \\lambda_s = \\lambda_{iou} = \\lambda_{edge} = \\lambda_{pdice} = \\lambda_{distance} = 1$\n\nA single reward signal (e.g., IoU-only) can provide an optimization signal but fails to cover all evaluation dimensions simultaneously. To validate this design, we conduct ablation experiments by removing individual reward terms. As shown below, removing either the IoU reward or the reasoning format reward leads to notable performance drops, confirming the necessity of multi-dimensional reward supervision. We will supplement complete sensitivity experiments for different $\\lambda$ scaling factors in our appendix.\n\n| Reward Variant | IoU % | pDice % | Dice % |\n|--------|-------|---------|--------|\n| Full reward (Ours) | 44.22 | 11.66 | 44.78 |\n| Remove IoU reward | 34.21 | 8.46 | 35.21 |\n| Remove reasoning format reward | 31.71 | 7.72 | 31.97 |\n\n\nQ8. Table 2 shows that objective difficulty improves Dice but slightly decreases IoU. Why does emphasizing difficult samples lead to worse localization accuracy while improving segmentation quality?\n\nA8. Great observation. Objective difficulty is defined purely by mask size (smaller targets get higher weights). Over-emphasizing extremely small targets during RL can cause the predicted bounding boxes to become overly tight or \"shrink\" towards the tiny foreground, slightly reducing box IoU. However, because these small targets often have high-contrast boundaries, the mask Dice score (which measures pixel overlap within the prompted region) improves. Our dynamic fusion strategy resolves this trade-off by incorporating subjective difficulty (rollout correctness), which prevents overfitting to the smallest outliers and achieves the best balance between IoU (44.22) and Dice (44.78)."+ },+ "createdAt": "2026-07-28T07:23:58.048Z",+ "modifiedAt": "2026-11-18T17:12:47.980Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=5yx0ZBSHke",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/eywd6lqitd.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/eywd6lqitd.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "EYwd6lqITD",+ "replyTo": null,+ "kind": "review",+ "invitation": "Ethics_Review",+ "signature": "Ethics Reviewer hfcf",+ "content": {+ "scope_of_ethics_concerns": "Moderate ethical concerns (can likely be resolved) (yellow)",+ "ethics_review": "### 1. Data Governance and Redistribution Rights\n* **Severity**: Moderate\n* **Concern**: The paper constructs a benchmark dataset (`SurgSeg-14K`) by combining eight public datasets with one unnamed private surgical dataset. The manuscript currently lacks detailed documentation regarding licensing agreements and legal redistribution rights for the aggregated data. If redistribution rights are not properly secured, publishing this benchmark could violate institutional data-sharing agreements or intellectual property boundaries.\n* **Mitigation Needed**: The authors must explicitly clarify the licensing terms and redistribution rights for all third-party public datasets utilized. Additionally, they must explain how reproducibility will be maintained for the research community if the private clinical dataset cannot be openly shared.\n\n### 2. Validation of Synthetic Clinical Annotations\n* **Severity**: Moderate\n* **Concern**: The clinical reasoning chains and annotations within the dataset were heavily generated using a commercial multimodal model (GPT-4o) under a scripted prompting protocol. Because only a random sample of these trajectories underwent manual expert review, there is a distinct risk that uncorrected factual or logical hallucinations have been introduced into a high-stakes surgical domain.\n* **Mitigation Needed**: The authors need to provide clear, quantitative metrics regarding their expert validation process. Specifically, they must state the exact percentage of the dataset that was manually verified, the error or rejection rates encountered during the review phase, and the systematic protocol used to handle disagreements between expert clinical reviewers.\n\n### 3. Safety Guardrails and Clinical Utility\n* **Severity**: Minor\n* **Concern**: The model shifts away from standard medical terminology to evaluate spatial segmentation based on ambiguous or \"implicit\" expressions. Relying on automated interpretation of clinical ambiguity introduces safety risks in a live surgical workflow if the underlying reasoning chains fail or experience catastrophic localization errors on small, occluded targets.\n* **Mitigation Needed**: The authors must include a dedicated safety and clinical utility discussion. They need to justify the real-world application of the implicit query paradigm (e.g., for automated video indexing or post-operative training) and explicitly outline necessary guardrails, such as maintaining strict human-in-the-loop oversight to prevent clinical errors."+ },+ "createdAt": "2026-07-19T22:30:46.236Z",+ "modifiedAt": "2026-11-18T13:50:33.128Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=EYwd6lqITD",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/fkjhlwfsl5.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/fkjhlwfsl5.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "fkJhlWfSl5",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "(a) Summary\nThis paper introduces a new task termed Surgical Reasoning Segmentation, which aims to infer a target surgical instrument or anatomical structure from an implicit clinical query and generate a pixel-level segmentation mask. Experimental results show consistent improvements over general, medical, and grounding baselines.\n\n(b) Pros\n+ The paper studies an important and underexplored surgical vision-language task. \n+ The authors present a valuable benchmark SurgSeg-14K with diverse surgical scenarios and fine-grained targets. \n+ The paper is clearly written, well organized, and provides sufficient information for readers.\n\n(c) Cons\n+ The practical significance of the proposed Surgical Reasoning Segmentation task remains somewhat unclear, and further clarification from the authors is encouraged. In real surgical settings, the operators are experienced medical professionals who are already well acquainted with the instruments and organs requiring segmentation. It is therefore worth questioning whether implicit reasoning instructions are genuinely necessary in such scenarios. \n+ Compared with existing reasoning segmentation approaches, the SurgReasoner method does not appear to introduce substantial technical advancements. The main contributions seem to be largely confined to the construction of the benchmark and the introduction of a dynamic difficulty‑aware advantage reweighting strategy.\n+ Please clarify the expert validation protocol for SurgSeg-14K, including how many samples were reviewed, how disagreements were handled, and whether correction and rejection rates are available.\n+ Could the authors provide a more comparable baseline setting, for example by fine-tuning representative strong baselines on SurgSeg-14K or explaining why this is infeasible?\n+ How were the generated reasoning trajectories checked for clinical correctness, and were common failure modes observed?\n+ Could the authors add or discuss expert evaluation of whether the predicted masks are clinically useful beyond standard segmentation metrics?\n+ How well does the method generalize to unseen surgical scenarios, categories, or external datasets? If external evaluation is unavailable, a held-out-scenario analysis or discussion would be helpful.\n+ Insufficient positioning with respect to existing referring segmentation literature. The paper repeatedly claims that existing surgical segmentation and VQA benchmarks do not support this task. However, the proposed setting appears highly related to referring image segmentation / reasoning segmentation, where language expressions are used to identify target regions.\n+ The motivation for implicit queries is not sufficiently justified. A central design choice of SurgSeg-14K is converting explicit targets into implicit descriptions. However, the paper never convincingly explains why this setting reflects realistic surgical practice. In actual clinical workflows, surgeons and trainees typically communicate using explicit instrument names and anatomical terminology. Therefore, why is the implicit formulation preferable?\n+ The necessity of reinforcement learning is not fully established. The core methodological contribution is RL-based optimization with dynamic difficulty-aware reweighting. However, the improvement from SFT to RL is shown only on the newly proposed benchmark. There is no evidence that RL provides benefits beyond this specific dataset construction. The paper does not evaluate whether the proposed strategy improves existing reasoning segmentation or referring segmentation benchmarks.\n+ Benchmark construction relies heavily on GPT-4o-generated annotations. The benchmark is largely generated using GPT-4o-produced descriptions, queries, and reasoning trajectories. The paper acknowledges that only a subset of samples is reviewed by experts. This raises several concerns, including: (1) GPT-4o may hallucinate descriptions or reasoning chains. (2) Only a random subset is manually verified. (3) No estimate is provided regarding annotation error rates. (4) It remains unclear how trustworthy the reasoning trajectories are.\n+ Experimental comparisons are not entirely fair. The paper explicitly states that SurgReasoner is trained on SurgSeg-14K, whereas most baselines are evaluated in an off-the-shelf prompting setting. This creates a substantial fairness issue.\n+ The segmentation evaluation is heavily dependent on SAM2. All methods ultimately rely on the same SAM2-based segmentation pipeline. It remains unclear whether the proposed RL strategy generalizes to other segmentation models.\n\n(d) This work has mixed ratings, and they are '4.borderline accept', '3.borderline reject', and '2.reject'. If the rebuttal can address most concerns and the reviewers can upgrade their ratings, I will change the decision.",+ "final_justification": "(1) After the rebuttal, the positive reviewer maintained the score, since the rebuttal addressed the major concerns. \n\n(2) The negative reviewer has increased the score from 2 to 4 in the final justification, since the rebuttal addressed or partially addressed most of the major concerns. \n\n(3) Another negative reviewer also claimed that the response has addressed most of my concerns, but the reviewer thought this work is a borderline paper. The construction of a reasoning segmentation benchmark is a valuable contribution, but the practical applications and potential impact should be further clarified. The methodological novelty is relatively modest compared to the broader reasoning segmentation literature. Overall, the reviewer also agreed that this work is marginally acceptable given the specific challenges of the medical domain.\n\nAfter checking the paper and the rebuttal, this work can be accepted in NeurIPS 2026."+ },+ "createdAt": "2026-09-24T11:18:23.998Z",+ "modifiedAt": "2026-11-18T14:53:39.316Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=fkJhlWfSl5",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/ltdwd81op0.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/ltdwd81op0.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "lTDwd81Op0",+ "replyTo": "OyctJQNhpk",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Many thanks for your valuable comments and questions, which greatly help us improve this work. We address your questions as follows.\n\nQ1. Please clarify the expert validation protocol for SurgSeg-14K, including how many samples were reviewed, how disagreements were handled, and whether correction and rejection rates are available.\n\nA1. We appreciate the request for more details. SurgSeg-14K contains approximately 14,000 instances. We conducted a 50% stratified sample review (7,000 instances) as a first-pass by 8 medically trained student reviewers, evaluating query plausibility, target uniqueness, and mask-rationale consistency. Borderline/uncertain cases (e.g., ambiguous functional states, multiple similar instruments) were escalated to 3 clinical experts for secondary review and final decision-making. Across the reviewed subset, approximately 10-15% of samples required text-only corrections (e.g., clarifying spatial references), and approximately 3-5% were rejected/removed due to unrecoverable inconsistencies. We will add these detailed statistics, inter-reviewer disagreement resolution criteria, and examples of corrected/rejected cases to Appendix A.\n\n\nQ2. Could the authors provide a more comparable baseline setting, for example by fine-tuning representative strong baselines on SurgSeg-14K or explaining why this is infeasible?\n\nA2. We appreciate this constructive suggestion. We agree that fine-tuning representative strong baselines on SurgSeg-14K provides a more rigorous evaluation of our method. Therefore, we conducted additional experiments by training representative baselines on the SurgSeg-14K training split under the same training and evaluation protocols as SurgReasoner.\n\nSpecifically, we compare with three categories of baselines: (1) representative MLLM-based approaches fine-tuned with SFT, including Qwen2.5-VL, InternVL3, and LLaVA-based models; (2) a strong referring segmentation baseline, LISA-7B (based on LLaVA-1.5); and (3) a reasoning-aware segmentation baseline, MedReasoner. All baselines are trained using the same SurgSeg-14K training split and evaluated on the same test set with identical metrics.\n\nUnder this matched-training setting, SurgReasoner consistently achieves superior performance over these baselines, demonstrating that the improvements are not merely due to domain adaptation or exposure to the benchmark training data, but come from our proposed reasoning segmentation framework. We will include these additional comparisons in the revised manuscript.\n\n| Method | Training | IoU % | pDice % | Dice % |\n|--------|----------|-------|---------|--------|\n| Qwen2.5-VL-7B+sam2 | SFT | 28.13 | 5.45 | 29.19 |\n| LLaVA-1.5-7B+sam2 | SFT | 19.21 | 4.76 | 21.03 |\n| InternVL3-8B+sam2 | SFT | 12.12 | 3.45 | 13.64 |\n| Qwen2.5-VL-7B+sam2 | RL | 40.83 | 9.85 | 41.07 |\n| LISA-7B-LLaVA1.5 | SFT | 22.74 | 5.21 | 24.56 |\n| Medreasoner | SFT+RL | 41.42 | 9.61 | 41.73 |\n| SurgReasoner (Ours) | RL | 44.22 | 11.66 | 44.78 |\n\n\nQ3. How were the generated reasoning trajectories checked for clinical correctness, and were common failure modes observed?\n\nA3. We treat the reasoning trajectory as a structured localization rationale rather than authoritative clinical narration, and we applied strict QC: (1) Constrained generation: Prompts restrict trajectories to observable visual cues (appearance, spatial relations, contact) and forbid unverifiable claims. (2) Mask-consistency checks: We automatically verify that spatial statements align with the mask-derived geometry (bbox/centroid). (3) Human review: The 50% sampled review explicitly checked for clinical logic. The most common failure modes we observed and mitigated were: (i) hallucinated functional states (e.g., asserting \"cutting\" when the tool is idle), (ii) confusing visually similar instruments under heavy occlusion; (iii) over-specific anatomical assertions beyond the visible field. We will detail these failure modes in the revision.\n\n\nQ4. Could the authors add or discuss expert evaluation of whether the predicted masks are clinically useful beyond standard segmentation metrics?\n\nA4. We agree that metric-based evaluation alone is insufficient for assessing clinical utility. Surgical reasoning segmentation is an inherently challenging task, and current model performance remains at an early stage, not yet mature for direct clinical deployment. We view this as precisely the motivation for our benchmark: to drive community progress toward more capable visual reasoning and precise localization in surgical settings. To provide a preliminary clinical perspective, we invited experienced clinicians to qualitatively review predictions on a random test subset. SurgReasoner's outputs were found to be notably more acceptable than the strongest baseline for identifying target structures and instruments, suggesting meaningful potential for future clinical assistance.\n\n\nQ5. How well does the method generalize to unseen surgical scenarios, categories, or external datasets? If external evaluation is unavailable, a held-out-scenario analysis or discussion would be helpful.\n\nA5. To verify generalization, we leverage the natural distribution shift between the eight public datasets and our private clinical subset within SurgSeg-14K. Specifically, the model is trained exclusively on the eight public datasets (DSAD, EndoVis2017, EndoVis2018, CholecSeg8k, GraSP, AutoLaparo, Cataract-1K, and Kvasir-Instrument), and evaluated on the private clinical subset, which contains surgical scenarios not present in the public training data, serving as a natural out-of-distribution (OOD) evaluation. As shown in the table below, SFT generalizes poorly to this unseen distribution, while our difficulty-aware RL maintains robust grounding performance, confirming that RL learns transferable spatial reasoning rather than merely memorizing training patterns.\n\n| Method | IoU % | pDice % | Dice % |\n|--------|-------|---------|--------|\n| SFT | 25.03 | 5.52 | 27.17 |\n| GRPO | 32.21 | 7.23 | 34.12 |\n| SurgReasoner (Ours) | 36.57 | 9.76 | 37.89 |"+ },+ "createdAt": "2026-07-28T07:18:36.030Z",+ "modifiedAt": "2026-11-18T17:12:47.608Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=lTDwd81Op0",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/onz5ujhrn1.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/onz5ujhrn1.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "oNZ5ujhRN1",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair ZJbS",+ "content": {+ "metareview": "(a) Summary\nThis paper introduces a new task termed Surgical Reasoning Segmentation, which aims to infer a target surgical instrument or anatomical structure from an implicit clinical query and generate a pixel-level segmentation mask. Experimental results show consistent improvements over general, medical, and grounding baselines.\n\n(b) Pros\n+ The paper studies an important and underexplored surgical vision-language task. \n+ The authors present a valuable benchmark SurgSeg-14K with diverse surgical scenarios and fine-grained targets. \n+ The paper is clearly written, well organized, and provides sufficient information for readers.\n\n(c) Cons\n+ The practical significance of the proposed Surgical Reasoning Segmentation task remains somewhat unclear, and further clarification from the authors is encouraged. In real surgical settings, the operators are experienced medical professionals who are already well acquainted with the instruments and organs requiring segmentation. It is therefore worth questioning whether implicit reasoning instructions are genuinely necessary in such scenarios. \n+ Compared with existing reasoning segmentation approaches, the SurgReasoner method does not appear to introduce substantial technical advancements. The main contributions seem to be largely confined to the construction of the benchmark and the introduction of a dynamic difficulty‑aware advantage reweighting strategy.\n+ Please clarify the expert validation protocol for SurgSeg-14K, including how many samples were reviewed, how disagreements were handled, and whether correction and rejection rates are available.\n+ Could the authors provide a more comparable baseline setting, for example by fine-tuning representative strong baselines on SurgSeg-14K or explaining why this is infeasible?\n+ How were the generated reasoning trajectories checked for clinical correctness, and were common failure modes observed?\n+ Could the authors add or discuss expert evaluation of whether the predicted masks are clinically useful beyond standard segmentation metrics?\n+ How well does the method generalize to unseen surgical scenarios, categories, or external datasets? If external evaluation is unavailable, a held-out-scenario analysis or discussion would be helpful.\n+ Insufficient positioning with respect to existing referring segmentation literature. The paper repeatedly claims that existing surgical segmentation and VQA benchmarks do not support this task. However, the proposed setting appears highly related to referring image segmentation / reasoning segmentation, where language expressions are used to identify target regions.\n+ The motivation for implicit queries is not sufficiently justified. A central design choice of SurgSeg-14K is converting explicit targets into implicit descriptions. However, the paper never convincingly explains why this setting reflects realistic surgical practice. In actual clinical workflows, surgeons and trainees typically communicate using explicit instrument names and anatomical terminology. Therefore, why is the implicit formulation preferable?\n+ The necessity of reinforcement learning is not fully established. The core methodological contribution is RL-based optimization with dynamic difficulty-aware reweighting. However, the improvement from SFT to RL is shown only on the newly proposed benchmark. There is no evidence that RL provides benefits beyond this specific dataset construction. The paper does not evaluate whether the proposed strategy improves existing reasoning segmentation or referring segmentation benchmarks.\n+ Benchmark construction relies heavily on GPT-4o-generated annotations. The benchmark is largely generated using GPT-4o-produced descriptions, queries, and reasoning trajectories. The paper acknowledges that only a subset of samples is reviewed by experts. This raises several concerns, including: (1) GPT-4o may hallucinate descriptions or reasoning chains. (2) Only a random subset is manually verified. (3) No estimate is provided regarding annotation error rates. (4) It remains unclear how trustworthy the reasoning trajectories are.\n+ Experimental comparisons are not entirely fair. The paper explicitly states that SurgReasoner is trained on SurgSeg-14K, whereas most baselines are evaluated in an off-the-shelf prompting setting. This creates a substantial fairness issue.\n+ The segmentation evaluation is heavily dependent on SAM2. All methods ultimately rely on the same SAM2-based segmentation pipeline. It remains unclear whether the proposed RL strategy generalizes to other segmentation models.\n\n(d) This work has mixed ratings, and they are '4.borderline accept', '3.borderline reject', and '2.reject'. If the rebuttal can address most concerns and the reviewers can upgrade their ratings, I will change the decision."+ },+ "createdAt": "2026-07-18T03:30:51.346Z",+ "modifiedAt": "2026-11-18T15:19:53.822Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=oNZ5ujhRN1",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/oyctjqnhpk.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/oyctjqnhpk.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "OyctJQNhpk",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer KBi7",+ "content": {+ "summary": "The paper proposes SurgReasoner, a framework for surgical reasoning segmentation. Given an implicit clinical query, the model identifies the target instrument or anatomical structure and produces a pixel-level mask. The authors introduce SurgSeg-14K, a benchmark with over 14K image-query-mask samples across seven surgical scenarios and 30 categories. The method combines reasoning-based spatial prompt generation, a frozen SAM2 segmentation module, and dynamic difficulty-aware GRPO training. Experiments show consistent improvements over general, medical, and grounding baselines.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths:\nThe paper studies an important and underexplored surgical vision-language task. SurgSeg-14K is a valuable benchmark with diverse surgical scenarios and fine-grained targets. The method is well motivated: decomposing reasoning and segmentation is practical, and the difficulty-aware RL design fits the surgical setting where targets vary in size, visibility, and ambiguity. The experiments include multiple baselines, ablations, hard-target analysis, and appendix details.\n\nWeaknesses:\nThe dataset relies partly on generated queries and reasoning trajectories, but expert validation details are limited. Some baselines may not be trained or adapted under fully comparable conditions. The method mainly combines existing components, such as MLLM reasoning, SAM2 prompting, GRPO, and difficulty weighting, so the algorithmic novelty is moderate. The evaluation is mostly metric-based, with limited clinical expert assessment of whether the masks are useful in real surgical workflows.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "1. Please clarify the expert validation protocol for SurgSeg-14K, including how many samples were reviewed, how disagreements were handled, and whether correction and rejection rates are available.\n2. Could the authors provide a more comparable baseline setting, for example by fine-tuning representative strong baselines on SurgSeg-14K or explaining why this is infeasible?\n3. How were the generated reasoning trajectories checked for clinical correctness, and were common failure modes observed?\n4. Could the authors add or discuss expert evaluation of whether the predicted masks are clinically useful beyond standard segmentation metrics?\n5. How well does the method generalize to unseen surgical scenarios, categories, or external datasets? If external evaluation is unavailable, a held-out-scenario analysis or discussion would be helpful.",+ "limitations": "The paper discusses limitations such as frozen SAM2, small or occluded targets, and limited surgical scenarios. However, it should further discuss risks from generated reasoning data, dataset bias, private data governance, and the gap between benchmark results and real clinical deployment.",+ "rating": 4,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No major formatting concerns observed.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The authors' response address most of my concerns. I would like to maintain the score."+ },+ "createdAt": "2026-06-23T02:19:28.728Z",+ "modifiedAt": "2026-11-18T13:37:14.092Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=OyctJQNhpk",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/rgavjl6qst.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/rgavjl6qst.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "rGaVjl6QsT",+ "replyTo": "xCe4qd8kyq",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Many thanks for your valuable comments and questions, which greatly help us improve this work. We address your questions as follows.\n\nQ1. In surgical settings, the operators are professional surgeons who possess expert knowledge of surgical instruments and anatomical structures. Is it truly necessary to employ implicit reasoning instructions, rather than directly using explicit instrument or organ names? Furthermore, decoupled reasoning and segmentation is already a common paradigm in existing reasoning segmentation methods, and therefore may not constitute a meaningful contribution.\n\nA1. We clarify that the implicit reasoning queries in our work target future interactive surgical AI systems, rather than compensating for surgeons’ lack of anatomical knowledge. They represent latent surgical intent that guides models to identify clinically relevant entities under specific operative contexts. Unlike traditional segmentation with predefined categories, our task requires models to infer the target based on procedural goals and contextual understanding. Existing surgical segmentation methods mainly focus on fixed anatomical structures or instruments, while general-purpose MLLMs lack precise pixel-level grounding for open-ended clinical queries. For example, the query “What tissue structure must be gently displaced or avoided in this step?” does not explicitly name the target; the model must understand the surgical context and infer that the liver is relevant because it may obstruct exposure of the esophagogastric junction. We introduce clinically grounded reasoning traces that bridge surgical intent with pixel-level localization, enabling models to infer what to segment and why before generating the mask. This advances surgical segmentation from static recognition toward intent-driven surgical scene understanding.\n\nQ2. The expression \"an implicit clinical referring expression E\" in Section 4.1 and \"an implicit clinical query Q\" in Section 4.2 appear to refer to the same concept. If so, a unified notation is recommended for consistency. If they are intended to be distinct, the difference should be clearly explained.\n\nA2. They indeed refer to the same concept. We will unify the terminology to \"implicit clinical query\" throughout the manuscript (Sec. 4.1, 4.2) in the revision to avoid confusion.\n\nQ3. According to Section 4.2, is the MLLM first supervised fine-tuned on SurgSeg-14K and then further optimized using reinforcement learning? What is the rationale behind this two-stage optimization strategy? The authors also acknowledge in the limitations that \"its effectiveness is validated on seven typical surgical scenarios, which may limit its generalization to other surgical procedures with distinct imaging conditions.\" Given this concern, does supervised fine-tuning on a benchmark covering only seven surgical scenarios risk undermining the generalizability of the pre-trained MLLM?\n\nA3. Yes, the MLLM is first fine-tuned via SFT and then optimized through RL. The two stages serve distinct purposes: SFT establishes the required output structure (bounding box + spatial points) and domain-specific surgical vocabulary, while RL is specifically designed to enhance reasoning and precise localization — capabilities that SFT alone cannot reliably acquire. To rigorously assess generalizability, we conduct a cross-dataset evaluation: the model is trained exclusively on the eight public datasets (DSAD, EndoVis2017, EndoVis2018, CholecSeg8k, GraSP, AutoLaparo, Cataract-1K, and Kvasir-Instrument) and evaluated on our private clinical subset, which contains surgical scenarios and instrument distributions entirely absent from the training data, forming a strict out-of-distribution (OOD) test. As shown below, SFT generalizes poorly to this unseen distribution, while our difficulty-aware RL maintains robust performance — confirming that RL learns transferable spatial reasoning rather than merely memorizing training patterns.\n\n| Method | IoU % | pDice % | Dice % |\n|--------|-------|---------|--------|\n| SFT | 25.03 | 5.52 | 27.17 |\n| GRPO | 32.21 | 7.23 | 34.12 |\n| SurgReasoner (Ours) | 36.57 | 9.76 | 37.89 |\n\nQ4. In the experimental section, the compared methods are evaluated under an off‑the‑shelf prompting setting, whereas SurgReasoner is trained on the benchmark's training set. Is this a fair comparison? This setup appears to assess the generalization ability of the compared methods on unseen domains, rather than evaluating their intrinsic reasoning segmentation capabilities.\n\nA4. We appreciate this valid concern. Our original Table 1 was intended to demonstrate the difficulty of SurgSeg-14K under an off-the-shelf prompting setting; however, we agree that a matched-training comparison is necessary to fairly evaluate reasoning segmentation capability. To address this concern, we conducted additional experiments by fine-tuning representative baselines on the SurgSeg-14K training split under identical training and evaluation protocols. Specifically, we include three categories of methods: (1) representative MLLM backbones fine-tuned with SFT, including Qwen2.5-VL, InternVL3, and LLaVA-based models; (2) a state-of-the-art referring segmentation method, LISA-7B (based on LLaVA-1.5); and (3) a reasoning-aware segmentation method, MedReasoner. All methods are trained on the same SurgSeg-14K training split and evaluated on the same test set using identical metrics. Under this matched-training setting, SurgReasoner consistently outperforms all competing methods, demonstrating that the performance gains come from our proposed reasoning segmentation framework rather than differences in training data, evaluation protocols, or domain adaptation effects. We will include these additional comparisons in the revised manuscript.\n\n| Method | Training | IoU % | pDice % | Dice % |\n|--------|----------|-------|---------|--------|\n| Qwen2.5-VL-7B+sam2 | SFT | 28.13 | 5.45 | 29.19 |\n| LLaVA-1.5-7B+sam2 | SFT | 19.21 | 4.76 | 21.03 |\n| InternVL3-8B+sam2 | SFT | 12.12 | 3.45 | 13.64 |\n| Qwen2.5-VL-7B+sam2 | RL | 40.83 | 9.85 | 41.07 |\n| LISA-7B-LLaVA1.5 | SFT | 22.74 | 5.21 | 24.56 |\n| Medreasoner | SFT+RL | 41.42 | 9.61 | 41.73 |\n| SurgReasoner (Ours) | RL | 44.22 | 11.66 | 44.78 |\n\nQ5. The Dynamic Difficulty‑Aware Advantage Reweighting strategy involves several hyperparameters, such as A, B, and k. However, no specific values or settings for these hyperparameters are provided in the Implementation Details. It is recommended that additional experiments be conducted to analyze the sensitivity or robustness of these hyperparameters.\n\nA5. A and B define the output range of the reweighting function. A = 0.5 ensures that easy samples (high correct ratio) retain non-trivial gradient contributions and do not vanish during training, while B = 1.5 provides moderate upweighting for hard samples without allowing them to dominate. These two parameters serve as hard boundary constraints for training stability rather than continuously tunable sensitivity parameters — extreme settings (e.g., A → 0 or B ≫ 2) would directly cause gradient imbalance. Their validity is therefore supported by the overall method's effectiveness rather than isolated ablation. We focus the sensitivity analysis on k, which is the functionally critical parameter governing how sharply the model distinguishes between difficulty levels. We vary k by 0.5× and 2.0× while keeping all other parameters fixed:\n\n| Variant | IoU % | pDice % | Dice % |\n|---------|-------|---------|--------|\n| k = 10.0 | 44.22 | 11.66 | 44.78 |\n| k = 5.0 | 43.12 | 10.92 | 43.14 |\n| k = 20.0 | 43.51 | 11.06 | 44.12 |"+ },+ "createdAt": "2026-07-28T07:18:10.616Z",+ "modifiedAt": "2026-11-18T17:12:47.869Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=rGaVjl6QsT",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/t3odphwex7.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/t3odphwex7.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "T3oDPhWeX7",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer 4Vs4",+ "content": {+ "summary": "This paper introduces a new task termed Surgical Reasoning Segmentation, where a model is required to infer a target surgical instrument or anatomical structure from an implicit clinical query and generate a pixel-level segmentation mask. To support this task, the authors construct SurgSeg-14K, a benchmark containing over 14K image-mask-query pairs collected from multiple surgical datasets. The proposed framework, SurgReasoner, decomposes the task into (1) reasoning-based spatial prompt generation using a multimodal LLM and (2) mask generation using a frozen SAM2 segmentation backbone. The reasoning module is optimized via GRPO-based reinforcement learning with a dynamic difficulty-aware advantage reweighting strategy. The paper reports improvements over several general-purpose, medical-domain, and grounding-oriented MLLMs on the proposed benchmark.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths\n1. The proposed architecture decouples reasoning from segmentation by optimizing only the MLLM while keeping the segmentation model frozen. This design is computationally efficient and avoids retraining a large segmentation backbone.\n\nWeaknesses\n1. Insufficient positioning with respect to existing referring segmentation literature. The paper repeatedly claims that existing surgical segmentation and VQA benchmarks do not support this task. However, the proposed setting appears highly related to referring image segmentation / reasoning segmentation, where language expressions are used to identify target regions.\n2. The motivation for implicit queries is not sufficiently justified. A central design choice of SurgSeg-14K is converting explicit targets into implicit descriptions. However, the paper never convincingly explains why this setting reflects realistic surgical practice. In actual clinical workflows, surgeons and trainees typically communicate using explicit instrument names and anatomical terminology. Therefore, why is the implicit formulation preferable?\n3. The necessity of reinforcement learning is not fully established. The core methodological contribution is RL-based optimization with dynamic difficulty-aware reweighting. However, the improvement from SFT to RL is shown only on the newly proposed benchmark. There is no evidence that RL provides benefits beyond this specific dataset construction. The paper does not evaluate whether the proposed strategy improves existing reasoning segmentation or referring segmentation benchmarks.\n4. Benchmark construction relies heavily on GPT-4o-generated annotations. The benchmark is largely generated using GPT-4o-produced descriptions, queries, and reasoning trajectories. The paper acknowledges that only a subset of samples is reviewed by experts. This raises several concerns, including: (1) GPT-4o may hallucinate descriptions or reasoning chains. (2) Only a random subset is manually verified. (3) No estimate is provided regarding annotation error rates. (4) It remains unclear how trustworthy the reasoning trajectories are.\n5. Experimental comparisons are not entirely fair. The paper explicitly states that SurgReasoner is trained on SurgSeg-14K, whereas most baselines are evaluated in an off-the-shelf prompting setting. This creates a substantial fairness issue.\n6. The segmentation evaluation is heavily dependent on SAM2. All methods ultimately rely on the same SAM2-based segmentation pipeline. It remains unclear whether the proposed RL strategy generalizes to other segmentation models.",+ "quality": 2,+ "clarity": 2,+ "significance": 2,+ "originality": 3,+ "questions": "1. Relationship to referring segmentation.\nHow does the proposed task fundamentally differ from existing referring image segmentation or reasoning segmentation settings? Why are comparisons against established referring segmentation methods absent?\n2. Real-world motivation.\nCan the authors provide concrete surgical scenarios where clinicians naturally use implicit descriptions instead of directly naming instruments or anatomical structures?\n3. RL generalization.\nWould the proposed dynamic difficulty-aware reweighting strategy still provide gains on existing referring segmentation or grounding benchmarks outside SurgSeg-14K?\n4. Dataset quality.\nOnly a subset of generated samples is reviewed by experts. What percentage of the dataset was manually inspected? What was the observed error rate?\n5. Dataset licensing and release.\nThe benchmark combines multiple public datasets and one private dataset. Are redistribution rights available for all source datasets? Will the benchmark be fully released? If the private dataset cannot be released, how will reproducibility be ensured?\n6. Spatial prompts.\nThe framework predicts two key points (P1 and P2) in addition to the bounding box. Why are two points required? One point appears related to the centroid. What is the semantic role of the second point? Was a single-point formulation evaluated?\n7. Ablation of reward design.\nThe reward contains multiple manually weighted components. How sensitive are results to λf, λs, λiou, λedge, λpdice, and λdistance? Could a simpler reward achieve similar performance?\n8. Objective difficulty weighting.\nTable 2 shows that objective difficulty improves Dice but slightly decreases IoU. Why does emphasizing difficult samples lead to worse localization accuracy while improving segmentation quality?",+ "limitations": "Yes",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "Major Concern: Data privacy, copyright, and consent"+ ],+ "paper_formatting_concerns": "N/A",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "Thank the authors for their detailed response. The rebuttal addresses or partially addresses most of my major concerns, particularly by adding referring segmentation baselines, demonstrating the generalization of the RL strategy on ReasonSeg, clarifying the dataset review process, and providing additional ablations. Although some limitations remain regarding real-world motivation and dependence on SAM2, the new evidence substantially improves my confidence in the work. I therefore raise my score to 4 (Borderline accept)."+ },+ "createdAt": "2026-06-03T05:33:56.191Z",+ "modifiedAt": "2026-11-18T13:37:15.650Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=T3oDPhWeX7",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/upojw6rtzy.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/upojw6rtzy.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "UpOjw6rTZY",+ "replyTo": null,+ "kind": "review",+ "invitation": "Ethics_Review",+ "signature": "Ethics Reviewer JLEV",+ "content": {+ "scope_of_ethics_concerns": "Moderate ethical concerns (can likely be resolved) (yellow)",+ "ethics_review": "# Summary\nThe research topic is relevant and the authors of the paper share that surgical data (SurgSeg-14K Dataset) used in the paper are anonymized and is intended solely for research purposes. They share that it is a mix of multiple public datasets and one private dataset. The primary ethical concerns arise from the omission of provenance and consent information of this private dataset. It is likely that authors will be able to provide further clarification that can resolve the ethical concerns regarding the private dataset.\n\n# Ethical Concerns\n## Private Dataset related issues:\nIn the sections 1 and 3.1 authors state that SurgSeg-14K is built using 8 open source datasets and one private dataset. Whereas in Appendix A, they only share details about the public datasets and no information regarding the source and permissions associated with the private dataset.\n\nIn relation to this, Questions 14 and 15 are also answered as N/A, indicating that work doesn't involve human subjects and doesn't require IRB approval. These statements aren't justified fully with the dataset and concerns raised above.\n\nThis also appears inconsistent with the Ethics Statement, which states that all surgical images came from ethically approved public datasets.\n\n### Required action from authors:\n- Share details on whether private dataset was indeed used, if used what are its contributions in each split and what type of data was present in private dataset (porcine/human)\n- Separate human and animal information separately and clearly.\n- Share whether authorizations from public datasets cover the redistribution of images and derived information.\n- Provide the applicable IRB or ethics approval, waiver, consent, or equivalent authorization for the private dataset.\n\n## Dataset licensing and release\n- Authors answered \"Yes\" to Checklist question 12 and state that all assets comply with their original terms. However, it is hard to trace down the licenses and access restrictions that are in place for each of member dataset utilized in the paper to build \"SurgSeg-14K\" dataset. This combined with the usage of a private dataset prevents verification of author's right to distribute this dataset.\n\n### Required action from authors:\nProvide a source-by-source license information and explain the license compatibility for the derived benchmark."+ },+ "createdAt": "2026-07-14T06:46:10.090Z",+ "modifiedAt": "2026-11-18T13:50:34.778Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=UpOjw6rTZY",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/xce4qd8kyq.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/xce4qd8kyq.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "xCe4qd8kyq",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer YL3L",+ "content": {+ "summary": "This paper introduces the task of surgical reasoning segmentation. A benchmark named SurgSeg‑14K is constructed to support this task, and the SurgReasoner method is proposed, which performs reasoning segmentation in a decoupled manner. To address the specific challenges inherent to this task, a dynamic difficulty‑aware reweighting strategy is further designed.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths and Weaknesses:\n\nStrengths:\n\nThis paper presents the novel task of Surgical Reasoning Segmentation, along with a benchmark and method designed specifically for it. To handle clinically important hard cases, e.g., tiny instruments and partially occluded organs, a dynamic difficulty‑aware advantage reweighting strategy is introduced for GRPO. The paper is clearly written, well organized, and provides sufficient information for readers.\n\nWeaknesses:\n\n1.The practical significance of the proposed Surgical Reasoning Segmentation task remains somewhat unclear, and further clarification from the authors is encouraged. In real surgical settings, the operators are experienced medical professionals who are already well acquainted with the instruments and organs requiring segmentation. It is therefore worth questioning whether implicit reasoning instructions are genuinely necessary in such scenarios.\n2.Compared with existing reasoning segmentation approaches, the SurgReasoner method does not appear to introduce substantial technical advancements. The main contributions seem to be largely confined to the construction of the benchmark and the introduction of a dynamic difficulty‑aware advantage reweighting strategy.",+ "quality": 3,+ "clarity": 3,+ "significance": 2,+ "originality": 2,+ "questions": "1. In surgical settings, the operators are professional surgeons who possess expert knowledge of surgical instruments and anatomical structures. Is it truly necessary to employ implicit reasoning instructions, rather than directly using explicit instrument or organ names? Furthermore, decoupled reasoning and segmentation is already a common paradigm in existing reasoning segmentation methods, and therefore may not constitute a meaningful contribution.\n2. The expression \"an implicit clinical referring expression $E$\" in Section 4.1 and \"an implicit clinical query $Q$\" in Section 4.2 appear to refer to the same concept. If so, a unified notation is recommended for consistency. If they are intended to be distinct, the difference should be clearly explained.\n3. According to Section 4.2, is the MLLM first supervised fine‑tuned on SurgSeg‑14K and then further optimized using reinforcement learning? What is the rationale behind this two‑stage optimization strategy? The authors also acknowledge in the limitations that \"its effectiveness is validated on seven typical surgical scenarios, which may limit its generalization to other surgical procedures with distinct imaging conditions.\" Given this concern, does supervised fine‑tuning on a benchmark covering only seven surgical scenarios risk undermining the generalizability of the pre‑trained MLLM?\n4. In the experimental section, the compared methods are evaluated under an off‑the‑shelf prompting setting, whereas SurgReasoner is trained on the benchmark's training set. Is this a fair comparison? This setup appears to assess the generalization ability of the compared methods on unseen domains, rather than evaluating their intrinsic reasoning segmentation capabilities.\n5. The Dynamic Difficulty‑Aware Advantage Reweighting strategy involves several hyperparameters, such as $A$, $B$, and $k$. However, no specific values or settings for these hyperparameters are provided in the Implementation Details. It is recommended that additional experiments be conducted to analyze the sensitivity or robustness of these hyperparameters.",+ "limitations": "Yes",+ "rating": 3,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "no",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The authors' response has addressed most of my concerns. I regard this work as borderline. The construction of a reasoning segmentation benchmark for the medical imaging domain is a valuable contribution to the community; however, the practical applications and potential impact should be further clarified. The methodological novelty is relatively modest compared to the broader reasoning segmentation literature, but it is marginally acceptable given the specific challenges of the medical domain."+ },+ "createdAt": "2026-06-24T03:16:32.504Z",+ "modifiedAt": "2026-11-18T13:37:13.193Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=xCe4qd8kyq",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/submission.json added
+++ b/reviews/openreview/3s2pcxyuis/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "3S2PCXYUIS",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 8627,+ "url": "https://openreview.net/forum?id=3S2PCXYUIS",+ "license": "CC-BY-4.0"+}
versions/v_3tc8pjb4.json added
+++ b/versions/v_3tc8pjb4.json@@ -0,0 +1,22 @@+{+ "date": "2026-04-30",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 8627,+ "url": "https://openreview.net/forum?id=3S2PCXYUIS",+ "reviews": "openreview/3s2pcxyuis",+ "evidence": [+ "https://openreview.net/forum?id=3S2PCXYUIS"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=3S2PCXYUIS",+ "evidence": [+ "https://openreview.net/forum?id=3S2PCXYUIS"+ ]+}