SurgReasoner: Surgical Reasoning Segmentation with Dynamic Difficulty-Aware Reinforcement Learning
Update NeurIPS 2026 submission 3S2PCXYUIS: 17 notes
@openreview[bot] · 2026-11-24 15:45 UTC · 8467b3142cec ·
reviews/openreview/3s2pcxyuis/notes/4xj81p7ns1.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/4xj81p7ns1.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "4Xj81P7ns1",+ "replyTo": "EYwd6lqITD",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Data Governance and Redistribution Rights",+ "comment": "We sincerely thank the reviewers for raising these important ethical considerations. We appreciate the opportunity to clarify the data governance, annotation validation, and intended usage of SurgReasoner.\n\nQ1: Data Governance and Redistribution Rights\n\nA1: SurgSeg-14K is constructed from eight publicly available surgical datasets and one in-house dataset. We have reviewed the usage terms of each public dataset and we provide a detailed dataset provenance table in the response, including source, license, subject type, and redistribution policy.\n\n| Dataset | Source | License / Access Terms | Subject Type | Redistribution Policy |\n|---|---|---|---|---|\n| DSAD | Public surgical dataset | CC BY 4.0 | Human surgical videos | Redistribution and derivative works are permitted with appropriate attribution and compliance with license requirements |\n| EndoVis2017 | MICCAI Endoscopic Vision Challenge dataset | Raw image frames follow the original challenge access policy; no explicit raw-image redistribution license | Ex-vivo porcine (pig) surgical videos | Original frames will not be redistributed. We will release derived annotations, reasoning trajectories, and preprocessing scripts to enable reproducibility using the original data source |\n| EndoVis2018 | MICCAI Endoscopic Vision Challenge dataset | Raw image frames follow the original challenge access policy; no explicit raw-image redistribution license | Ex-vivo porcine (pig) surgical videos | Original frames will not be redistributed. We will release derived annotations, reasoning trajectories, and preprocessing scripts to enable reproducibility using the original data source |\n| CholecSeg8k | Public laparoscopic segmentation dataset | CC BY-NC-SA 4.0 | Human laparoscopic surgery videos | Redistribution and derivative works are permitted for non-commercial purposes under the same license conditions |\n| GraSP | Public surgical dataset | MIT License / dataset-specific access terms | Human surgical videos | Redistribution follows the original dataset terms with appropriate attribution. |\n| AutoLaparo | Public laparoscopic dataset | CC BY-NC-SA 4.0 | Human laparoscopic surgery videos | Derived benchmark components will follow the original non-commercial share-alike requirements |\n| Cataract-1K | Public ophthalmic surgical dataset | CC BY 4.0 | Human cataract surgery videos | Redistribution and derivative works are permitted with appropriate attribution |\n| Kvasir-Instrument | Public endoscopic dataset | CC BY 4.0 | Human endoscopic videos | Redistribution and derivative works are permitted with appropriate attribution |\n| In-house dataset | Institutionally collected clinical dataset | Institutional IRB approval and approved data-sharing protocol | De-identified human surgical videos | De-identified images and annotations can be publicly released in accordance with the approved institutional data-sharing protocol for academic research purposes |\n\nOnly EndoVis2017 and EndoVis2018 do not permit direct redistribution of raw frames; for these we release derived annotations and preprocessing scripts following community practice. All other datasets are shared per their respective licenses.\n\nThe private dataset consists of 600 high-resolution (1920×1080) frames collected from real surgical procedures at a tertiary hospital. All frames were annotated by 3 clinical experts with consensus labels. The data were collected under IRB approval with all PII removed, and the approved protocol permits public release of de-identified data for academic research. We will release the de-identified videos, annotations, masks, and raw frames together with appropriate documentation. We acknowledge the checklist did not sufficiently clarify this and will revise accordingly."+ },+ "createdAt": "2026-07-30T07:49:05.918Z",+ "modifiedAt": "2026-11-19T17:18:42.960Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=4Xj81P7ns1",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/6u6osbot9s.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/6u6osbot9s.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "6U6OSbot9s",+ "replyTo": "YX5YReuLr4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the valuable comment.\n\nFor baseline comparability: Table 1 follows the standard evaluation protocol adopted by MedReasoner, where existing MLLMs and reasoning segmentation methods are evaluated in their original off‑the‑shelf setting, while SurgReasoner is trained on SurgSeg‑14K. The purpose of this comparison is two‑fold: (1) to evaluate how well existing reasoning segmentation methods generalize to the newly proposed surgical reasoning segmentation benchmark, and (2) to demonstrate the performance achieved by a model specifically optimized for this task. \n\nTo address the reviewer’s concerns regarding baseline comparability, we have supplemented these additional matched‑training experiments in our preceding response. Several representative baselines are retrained on the SurgSeg‑14K training split under identical training and evaluation protocols. SurgReasoner achieves better segmentation performance under this setting, verifying the effectiveness of our approach on the surgical reasoning segmentation task. Following the reviewer’s suggestion, we will clearly distinguish fine‑tuned baselines from off‑the‑shell prompting baselines in the revised manuscript.\n\nRegarding the practical significance of the implicit‑query setting: We clarify that the implicit reasoning queries in our work target future interactive surgical AI systems, rather than compensating for surgeons’ lack of anatomical knowledge. They represent latent surgical intent that guides models to identify clinically relevant entities under specific operative contexts. Unlike traditional segmentation with predefined categories, our task requires models to infer the target based on procedural goals and contextual understanding. Existing surgical segmentation methods mainly focus on fixed anatomical structures or instruments, while general‑purpose MLLMs lack precise pixel‑level grounding for open‑ended clinical queries. For example, the query “What tissue structure must be gently displaced or avoided in this step?” does not explicitly name the target; the model must understand the surgical context and infer that the liver is relevant because it may obstruct exposure of the esophagogastric junction. We introduce clinically grounded reasoning traces that bridge surgical intent with pixel‑level localization, enabling models to infer what to segment and why before generating the mask. This advances surgical segmentation from static recognition toward intent‑driven surgical scene understanding.\n\nFinally, consistent with the reviewer’s suggestion, we will integrate complete discussions of data governance, annotation validation, and safety considerations into the revised manuscript."+ },+ "createdAt": "2026-08-04T11:46:26.571Z",+ "modifiedAt": "2026-11-19T17:18:42.359Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=6U6OSbot9s",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/8tg2cgldrt.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/8tg2cgldrt.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "8TG2cGLDRT",+ "replyTo": "oNZ5ujhRN1",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank the AC for the thoughtful summary of the reviewers' comments and the constructive feedback. We have carefully addressed each concern in our rebuttal and would like to briefly summarize the main clarifications and additional evidence.\n\nFirst, we clarify the motivation of Surgical Reasoning Segmentation. Our goal is not to replace explicit surgical communication, but to enable future interactive surgical AI systems to infer clinically relevant targets from implicit intent, procedural context, and functional descriptions.\n\nSecond, regarding technical novelty, we clarify that our contribution is not proposing a new reasoning segmentation paradigm, but addressing a key optimization challenge specific to surgical reasoning segmentation. We explain why severe sample-level difficulty imbalance is characteristic of surgical scenes and how our dynamic difficulty-aware optimization strategy explicitly improves learning on difficult surgical cases.\n\nThird, regarding benchmark quality, we provide additional details on the expert verification protocol, quality control process, reasoning validation, and annotation reliability, together with discussions of common failure modes.\n\nFinally, regarding the experimental concerns, we clarify the evaluation protocol adopted in Table 1, explain the distinction between benchmark comparison and controlled optimization evaluation, and add experimental comparisons with recent reasoning segmentation methods under the same protocol. We also discuss generalization and the dependence on the segmentation backbone.\n\nWe hope these clarifications and additional experimental results sufficiently address the reviewers' major concerns regarding task motivation, technical novelty, benchmark quality, and experimental evaluation. We sincerely appreciate the AC's consideration."+ },+ "createdAt": "2026-08-01T10:45:48.643Z",+ "modifiedAt": "2026-11-19T17:18:42.578Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=8TG2cGLDRT",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/fnwcbwpfkq.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/fnwcbwpfkq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "FnwCbWpFkq",+ "replyTo": "T3oDPhWeX7",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely appreciate your careful re-evaluation and the positive adjustment of your score.\nWe thank you for raising the concern regarding dependence on SAM2. Representative recent reasoning segmentation approaches including SegZero and VisionReasoner adopt SAM2 as the segmentation backbone, and we follow this common technical choice. In addition, we have included ablation studies using different SAM versions in the appendix. Experimental results demonstrate that SurgReasoner achieves stable performance across these versions."+ },+ "createdAt": "2026-08-03T09:16:34.727Z",+ "modifiedAt": "2026-11-19T17:18:42.576Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=FnwCbWpFkq",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/fx8zielqtr.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/fx8zielqtr.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "fX8zielqtr",+ "replyTo": "x23A1nvcre",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 4Vs4",+ "content": {+ "comment": "Thank the authors for their detailed response. The rebuttal addresses or partially addresses most of my major concerns, particularly by adding referring segmentation baselines, demonstrating the generalization of the RL strategy on ReasonSeg, clarifying the dataset review process, and providing additional ablations. Although some limitations remain regarding real-world motivation and dependence on SAM2, the new evidence substantially improves my confidence in the work. I therefore raise my score."+ },+ "createdAt": "2026-08-03T04:29:20.460Z",+ "modifiedAt": "2026-11-19T17:18:42.533Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=fX8zielqtr",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/hqbqbloesa.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/hqbqbloesa.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "hQBqBloESa",+ "replyTo": "rGaVjl6QsT",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "W2: Compared with existing reasoning segmentation approaches, the SurgReasoner method does not appear to introduce substantial technical advancements. The main contributions seem to be largely confined to the construction of the benchmark and the introduction of a dynamic difficulty‑aware advantage reweighting strategy.\n\nAnswer: We thank the reviewer for the insightful comment. We clarify that our contribution is not limited to benchmark construction or an isolated reweighting strategy.\n\nWe agree that SurgReasoner builds upon the existing reasoning segmentation paradigm rather than introducing a new task. Our focus is to investigate how reasoning segmentation can be effectively adapted to surgical scenarios, where small deformable targets, severe occlusions, visually similar instruments, and clinically grounded referring expressions introduce unique challenges for reliable pixel-level grounding.\n\nSurgSeg-14K is designed to enable this investigation by connecting clinical queries, reasoning trajectories, and pixel-level masks, which are not supported by existing surgical segmentation or VQA benchmarks. Beyond the benchmark, we propose a difficulty-aware RL optimization strategy to address the reward imbalance problem in surgical reasoning segmentation, where clinically important hard cases are often under-optimized by standard GRPO. The proposed strategy adaptively combines target difficulty and rollout difficulty, and consistently improves over vanilla and static weighting strategies.\n\nTherefore, the contribution of this work is not merely a dataset or a reward modification, but a systematic study of reasoning segmentation in surgical scenarios, including a dedicated benchmark and an optimization strategy tailored to its unique challenges."+ },+ "createdAt": "2026-07-30T07:47:21.054Z",+ "modifiedAt": "2026-11-19T17:18:43.174Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=hQBqBloESa",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/l0llz6k15y.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/l0llz6k15y.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "L0lLZ6K15Y",+ "replyTo": "EYwd6lqITD",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Safety Guardrails and Clinical Utility",+ "comment": "Q3: Safety Guardrails and Clinical Utility\n\nA3:\nWe thank the reviewer for raising this important safety concern. We clarify that the implicit query paradigm in SurgReasoner is not intended to replace standard surgical terminology or support autonomous intraoperative decision-making. Instead, it investigates a more flexible interaction paradigm for future surgical AI systems.Potential applications of this paradigm include surgical video indexing, education, retrospective procedure analysis, and decision-support research, where understanding intent-driven queries can enable more effective retrieval and organization of surgical knowledge. \n\nWe acknowledge that interpreting implicit expressions introduces additional safety challenges, particularly for small, occluded, or ambiguous targets. Therefore, SurgReasoner is designed as a research framework for surgical scene understanding and is not intended for direct clinical deployment. Any future clinical integration would require rigorous prospective validation and strict safety guardrails, including: (1) mandatory human-in-the-loop verification before clinical use; (2) uncertainty estimation and failure detection for ambiguous predictions; (3) independent evaluation by clinical experts; and (4) clear limitations against autonomous actions based solely on model-generated localization results.\n\nWe will add a dedicated discussion on safety limitations, intended applications, and responsible clinical translation in the revised manuscript."+ },+ "createdAt": "2026-07-30T07:51:17.498Z",+ "modifiedAt": "2026-11-19T17:18:43.177Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=L0lLZ6K15Y",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/llshikfd0s.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/llshikfd0s.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "lLsHiKfd0s",+ "replyTo": "UpOjw6rTZY",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Private Dataset related issues",+ "comment": "Q1: Private Dataset Related Issues\n\nA1:\nWe thank the reviewer for identifying these important ethical and data governance concerns. We agree that the original manuscript did not provide sufficient information regarding the provenance, ethical authorization, and redistribution policy of the in-house dataset. We provide the following clarification and will revise the manuscript, appendix, ethics statement, and checklist accordingly.\n\nIn-house dataset clarification\nSurgSeg-14K is constructed from eight publicly available surgical datasets and one institutionally collected in-house dataset. The in-house dataset was indeed used in benchmark construction and consists exclusively of de-identified human surgical video frames collected retrospectively from real surgical procedures. No animal or porcine data are included in the private dataset.\nThe in-house dataset contributes additional surgical scenarios, segmentation annotations, and reasoning-query annotations to SurgSeg-14K. The samples from the in-house dataset are incorporated into the benchmark following the same preprocessing and annotation pipeline as the public datasets. We will add detailed information regarding its contribution and data provenance in the revised appendix.\n\nHuman/animal data clarification\nWe will add a dataset provenance table specifying the subject type and acquisition setting for each dataset. Among the public datasets, EndoVis2017 and EndoVis2018 contain ex-vivo porcine tissue recordings, while the remaining six public datasets and our in-house dataset contain human surgical and endoscopic frames.\n\nEthical approval and data sharing authorization\nWe acknowledge that the original responses to Checklist Questions 14 and 15 did not sufficiently reflect the inclusion of the in-house clinical dataset. Although the data were fully de-identified before research use, the source recordings were obtained from real patient procedures and should have been described under the human-subject research category.\nThe in-house dataset was collected retrospectively under institutional ethical approval/IRB authorization. The approved protocol covers the use of de-identified surgical videos for academic research purposes and permits data sharing under appropriate safeguards. The corresponding ethics documentation can be provided to the Ethics Committee upon request.\nThe released data contain only de-identified information. No personally identifiable information is included in the released benchmark.\n\nRegarding redistribution authorization of public datasets, please refer to our response under “Dataset licensing and release”."+ },+ "createdAt": "2026-07-30T07:53:17.015Z",+ "modifiedAt": "2026-11-19T17:18:43.174Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=lLsHiKfd0s",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/nmftpxlikh.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/nmftpxlikh.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "nmFtpxLIkH",+ "replyTo": "UpOjw6rTZY",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Dataset licensing and release",+ "comment": "Q2: Dataset Licensing and Release\n\nA2: SurgSeg-14K is constructed from eight publicly available surgical datasets and one in-house dataset. We have reviewed the usage terms of each public dataset and we provide a detailed dataset provenance table in the response, including source, license, subject type, and redistribution policy.\n\n| Dataset | Source | License / Access Terms | Subject Type | Redistribution Policy |\n|---|---|---|---|---|\n| DSAD | Public surgical dataset | CC BY 4.0 | Human surgical videos | Redistribution and derivative works are permitted with appropriate attribution and compliance with license requirements |\n| EndoVis2017 | MICCAI Endoscopic Vision Challenge dataset | Raw image frames follow the original challenge access policy; no explicit raw-image redistribution license | Ex-vivo porcine (pig) surgical videos | Original frames will not be redistributed. We will release derived annotations, reasoning trajectories, and preprocessing scripts to enable reproducibility using the original data source |\n| EndoVis2018 | MICCAI Endoscopic Vision Challenge dataset | Raw image frames follow the original challenge access policy; no explicit raw-image redistribution license | Ex-vivo porcine (pig) surgical videos | Original frames will not be redistributed. We will release derived annotations, reasoning trajectories, and preprocessing scripts to enable reproducibility using the original data source |\n| CholecSeg8k | Public laparoscopic segmentation dataset | CC BY-NC-SA 4.0 | Human laparoscopic surgery videos | Redistribution and derivative works are permitted for non-commercial purposes under the same license conditions |\n| GraSP | Public surgical dataset | MIT License / dataset-specific access terms | Human surgical videos | Redistribution follows the original dataset terms with appropriate attribution. |\n| AutoLaparo | Public laparoscopic dataset | CC BY-NC-SA 4.0 | Human laparoscopic surgery videos | Derived benchmark components will follow the original non-commercial share-alike requirements |\n| Cataract-1K | Public ophthalmic surgical dataset | CC BY 4.0 | Human cataract surgery videos | Redistribution and derivative works are permitted with appropriate attribution |\n| Kvasir-Instrument | Public endoscopic dataset | CC BY 4.0 | Human endoscopic videos | Redistribution and derivative works are permitted with appropriate attribution |\n| In-house dataset | Institutionally collected clinical dataset | Institutional IRB approval and approved data-sharing protocol | De-identified human surgical videos | De-identified images and annotations can be publicly released in accordance with the approved institutional data-sharing protocol for academic research purposes |\n\nOnly EndoVis2017 and EndoVis2018 do not permit direct redistribution of raw frames; for these we release derived annotations and preprocessing scripts following community practice. All other datasets are shared per their respective licenses.\n\nThe private dataset consists of 600 high-resolution (1920×1080) frames collected from real surgical procedures at a tertiary hospital. All frames were annotated by 3 clinical experts with consensus labels. The data were collected under IRB approval with all PII removed, and the approved protocol permits public release of de-identified data for academic research. We will release the de-identified videos, annotations, masks, and raw frames together with appropriate documentation. We acknowledge the checklist did not sufficiently clarify this and will revise accordingly."+ },+ "createdAt": "2026-07-30T07:54:46.213Z",+ "modifiedAt": "2026-11-19T17:18:42.796Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=nmFtpxLIkH",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/onz5ujhrn1.json modified
+++ b/reviews/openreview/3s2pcxyuis/notes/onz5ujhrn1.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair ZJbS","content": {- "metareview": "(a) Summary\nThis paper introduces a new task termed Surgical Reasoning Segmentation, which aims to infer a target surgical instrument or anatomical structure from an implicit clinical query and generate a pixel-level segmentation mask. Experimental results show consistent improvements over general, medical, and grounding baselines.\n\n(b) Pros\n+ The paper studies an important and underexplored surgical vision-language task. \n+ The authors present a valuable benchmark SurgSeg-14K with diverse surgical scenarios and fine-grained targets. \n+ The paper is clearly written, well organized, and provides sufficient information for readers.\n\n(c) Cons\n+ The practical significance of the proposed Surgical Reasoning Segmentation task remains somewhat unclear, and further clarification from the authors is encouraged. In real surgical settings, the operators are experienced medical professionals who are already well acquainted with the instruments and organs requiring segmentation. It is therefore worth questioning whether implicit reasoning instructions are genuinely necessary in such scenarios. \n+ Compared with existing reasoning segmentation approaches, the SurgReasoner method does not appear to introduce substantial technical advancements. The main contributions seem to be largely confined to the construction of the benchmark and the introduction of a dynamic difficulty‑aware advantage reweighting strategy.\n+ Please clarify the expert validation protocol for SurgSeg-14K, including how many samples were reviewed, how disagreements were handled, and whether correction and rejection rates are available.\n+ Could the authors provide a more comparable baseline setting, for example by fine-tuning representative strong baselines on SurgSeg-14K or explaining why this is infeasible?\n+ How were the generated reasoning trajectories checked for clinical correctness, and were common failure modes observed?\n+ Could the authors add or discuss expert evaluation of whether the predicted masks are clinically useful beyond standard segmentation metrics?\n+ How well does the method generalize to unseen surgical scenarios, categories, or external datasets? If external evaluation is unavailable, a held-out-scenario analysis or discussion would be helpful.\n+ Insufficient positioning with respect to existing referring segmentation literature. The paper repeatedly claims that existing surgical segmentation and VQA benchmarks do not support this task. However, the proposed setting appears highly related to referring image segmentation / reasoning segmentation, where language expressions are used to identify target regions.\n+ The motivation for implicit queries is not sufficiently justified. A central design choice of SurgSeg-14K is converting explicit targets into implicit descriptions. However, the paper never convincingly explains why this setting reflects realistic surgical practice. In actual clinical workflows, surgeons and trainees typically communicate using explicit instrument names and anatomical terminology. Therefore, why is the implicit formulation preferable?\n+ The necessity of reinforcement learning is not fully established. The core methodological contribution is RL-based optimization with dynamic difficulty-aware reweighting. However, the improvement from SFT to RL is shown only on the newly proposed benchmark. There is no evidence that RL provides benefits beyond this specific dataset construction. The paper does not evaluate whether the proposed strategy improves existing reasoning segmentation or referring segmentation benchmarks.\n+ Benchmark construction relies heavily on GPT-4o-generated annotations. The benchmark is largely generated using GPT-4o-produced descriptions, queries, and reasoning trajectories. The paper acknowledges that only a subset of samples is reviewed by experts. This raises several concerns, including: (1) GPT-4o may hallucinate descriptions or reasoning chains. (2) Only a random subset is manually verified. (3) No estimate is provided regarding annotation error rates. (4) It remains unclear how trustworthy the reasoning trajectories are.\n+ Experimental comparisons are not entirely fair. The paper explicitly states that SurgReasoner is trained on SurgSeg-14K, whereas most baselines are evaluated in an off-the-shelf prompting setting. This creates a substantial fairness issue.\n+ The segmentation evaluation is heavily dependent on SAM2. All methods ultimately rely on the same SAM2-based segmentation pipeline. It remains unclear whether the proposed RL strategy generalizes to other segmentation models.\n\n(d) This work has mixed ratings, and they are '4.borderline accept', '3.borderline reject', and '2.reject'. If the rebuttal can address most concerns and the reviewers can upgrade their ratings, I will change the decision."+ "metareview": "(a) Summary\nThis paper introduces a new task termed Surgical Reasoning Segmentation, which aims to infer a target surgical instrument or anatomical structure from an implicit clinical query and generate a pixel-level segmentation mask. Experimental results show consistent improvements over general, medical, and grounding baselines.\n\n(b) Pros\n+ The paper studies an important and underexplored surgical vision-language task. \n+ The authors present a valuable benchmark SurgSeg-14K with diverse surgical scenarios and fine-grained targets. \n+ The paper is clearly written, well organized, and provides sufficient information for readers.\n\n(c) Cons\n+ The practical significance of the proposed Surgical Reasoning Segmentation task remains somewhat unclear, and further clarification from the authors is encouraged. In real surgical settings, the operators are experienced medical professionals who are already well acquainted with the instruments and organs requiring segmentation. It is therefore worth questioning whether implicit reasoning instructions are genuinely necessary in such scenarios. \n+ Compared with existing reasoning segmentation approaches, the SurgReasoner method does not appear to introduce substantial technical advancements. The main contributions seem to be largely confined to the construction of the benchmark and the introduction of a dynamic difficulty‑aware advantage reweighting strategy.\n+ Please clarify the expert validation protocol for SurgSeg-14K, including how many samples were reviewed, how disagreements were handled, and whether correction and rejection rates are available.\n+ Could the authors provide a more comparable baseline setting, for example by fine-tuning representative strong baselines on SurgSeg-14K or explaining why this is infeasible?\n+ How were the generated reasoning trajectories checked for clinical correctness, and were common failure modes observed?\n+ Could the authors add or discuss expert evaluation of whether the predicted masks are clinically useful beyond standard segmentation metrics?\n+ How well does the method generalize to unseen surgical scenarios, categories, or external datasets? If external evaluation is unavailable, a held-out-scenario analysis or discussion would be helpful.\n+ Insufficient positioning with respect to existing referring segmentation literature. The paper repeatedly claims that existing surgical segmentation and VQA benchmarks do not support this task. However, the proposed setting appears highly related to referring image segmentation / reasoning segmentation, where language expressions are used to identify target regions.\n+ The motivation for implicit queries is not sufficiently justified. A central design choice of SurgSeg-14K is converting explicit targets into implicit descriptions. However, the paper never convincingly explains why this setting reflects realistic surgical practice. In actual clinical workflows, surgeons and trainees typically communicate using explicit instrument names and anatomical terminology. Therefore, why is the implicit formulation preferable?\n+ The necessity of reinforcement learning is not fully established. The core methodological contribution is RL-based optimization with dynamic difficulty-aware reweighting. However, the improvement from SFT to RL is shown only on the newly proposed benchmark. There is no evidence that RL provides benefits beyond this specific dataset construction. The paper does not evaluate whether the proposed strategy improves existing reasoning segmentation or referring segmentation benchmarks.\n+ Benchmark construction relies heavily on GPT-4o-generated annotations. The benchmark is largely generated using GPT-4o-produced descriptions, queries, and reasoning trajectories. The paper acknowledges that only a subset of samples is reviewed by experts. This raises several concerns, including: (1) GPT-4o may hallucinate descriptions or reasoning chains. (2) Only a random subset is manually verified. (3) No estimate is provided regarding annotation error rates. (4) It remains unclear how trustworthy the reasoning trajectories are.\n+ Experimental comparisons are not entirely fair. The paper explicitly states that SurgReasoner is trained on SurgSeg-14K, whereas most baselines are evaluated in an off-the-shelf prompting setting. This creates a substantial fairness issue.\n+ The segmentation evaluation is heavily dependent on SAM2. All methods ultimately rely on the same SAM2-based segmentation pipeline. It remains unclear whether the proposed RL strategy generalizes to other segmentation models.\n\n(d) This work has mixed ratings, and they are '4.borderline accept', '3.borderline reject', and '2.reject'. If the rebuttal can address most concerns and the reviewers can upgrade their ratings, I will change the decision.",+ "final_justification": "(1) After the rebuttal, the positive reviewer maintained the score, since the rebuttal addressed the major concerns. \n\n(2) The negative reviewer has increased the score from 2 to 4 in the final justification, since the rebuttal addressed or partially addressed most of the major concerns. \n\n(3) Another negative reviewer also claimed that the response has addressed most of my concerns, but the reviewer thought this work is a borderline paper. The construction of a reasoning segmentation benchmark is a valuable contribution, but the practical applications and potential impact should be further clarified. The methodological novelty is relatively modest compared to the broader reasoning segmentation literature. Overall, the reviewer also agreed that this work is marginally acceptable given the specific challenges of the medical domain.\n\nAfter checking the paper and the rebuttal, this work can be accepted in NeurIPS 2026."},"createdAt": "2026-07-18T03:30:51.346Z",- "modifiedAt": "2026-11-18T15:19:53.822Z",+ "modifiedAt": "2026-11-19T04:59:57.245Z","url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=oNZ5ujhRN1","license": "CC-BY-4.0"}
reviews/openreview/3s2pcxyuis/notes/prpubhtm4y.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/prpubhtm4y.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "PRpUBhtm4Y",+ "replyTo": "EYwd6lqITD",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Validation of Synthetic Clinical Annotations",+ "comment": "Q2: Validation of Synthetic Clinical Annotations\n\nA2:\nWe thank the reviewer for raising this important concern. We clarify that the generated reasoning trajectories in SurgSeg-14K are used as structured visual localization rationales rather than authoritative clinical narratives. To reduce potential hallucinations, we adopted a multi-stage quality control protocol combining constrained generation, automatic consistency checking, and human validation.\n\nFirst, during generation, GPT-4o was guided by a structured prompting protocol that restricts reasoning trajectories to observable visual evidence, including instrument appearance, spatial relationships, and visible interactions, while avoiding unverifiable clinical claims. Second, we performed automatic mask-rationale consistency checks to verify whether spatial descriptions were aligned with segmentation-derived geometric properties (e.g., bounding boxes and centroids).\nFor human validation, SurgSeg-14K contains approximately 14,000 instances. We conducted a 50% stratified manual review (approximately 7,000 instances) covering diverse procedures, target categories, and query types. The first-pass review was performed by 8 medically trained annotators, who evaluated query plausibility, target uniqueness, and consistency between the reasoning trajectory and segmentation mask. Cases involving ambiguity or uncertainty (e.g., unclear functional states or visually similar instruments under occlusion) were escalated to 3 clinical experts for secondary review and final adjudication through consensus discussion.\n\nWithin the manually reviewed subset, approximately 10–15% of samples required text-level corrections, mainly involving refinement of spatial descriptions or clarification of ambiguous expressions. Approximately 3–5% of samples were rejected and removed due to unresolved inconsistencies between the generated rationale and visual evidence. The major failure modes identified included: (1) hallucinated functional states, such as describing an instrument as “cutting” when no active interaction was visible; (2) confusion between visually similar instruments under severe occlusion; and (3) overly specific anatomical descriptions beyond the observable field of view."+ },+ "createdAt": "2026-07-30T07:50:24.126Z",+ "modifiedAt": "2026-11-19T17:18:43.345Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=PRpUBhtm4Y",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/pysx8rjwnv.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/pysx8rjwnv.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "pysX8rJWnV",+ "replyTo": "yllqvPimm2",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We greatly appreciate your careful review. If you have any remaining concerns, we would like to provide further clarification."+ },+ "createdAt": "2026-08-03T05:34:55.782Z",+ "modifiedAt": "2026-11-19T17:18:42.577Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=pysX8rJWnV",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/ruuvfdxu59.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/ruuvfdxu59.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "RuUvFDXu59",+ "replyTo": "yllqvPimm2",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Novelty over VisionReasoner and reliability of Table 1 and VisionReasoner baseline.",+ "comment": "Q1: We thank the reviewer for pointing out the comparison with VisionReasoner. We agree that both works belong to the reasoning segmentation paradigm. Our novelty does not lie in intent-based referring or reasoning itself, but in addressing a challenge that is particularly prominent in surgical reasoning segmentation: large sample-level difficulty imbalance. Surgical images contain tiny instruments, severe occlusions, motion blur, smoke, and blood contamination, resulting in highly heterogeneous optimization difficulty across samples. Standard RL optimization treats all samples equally, causing clinically important hard cases to be under-optimized.\n\nTo address this issue, we propose a dynamic difficulty-aware optimization strategy that estimates both intrinsic target difficulty and model-dependent rollout difficulty, and adaptively reweights the optimization objective during training. This allows the model to progressively focus on difficult surgical cases while maintaining stable optimization.\n\nBy contrast, VisionReasoner extends reasoning segmentation toward multi-task visual reasoning through a routing mechanism, whereas our method focuses on difficulty-aware RL optimization for challenging surgical scenes. The two approaches therefore address different aspects of reasoning segmentation and are complementary rather than directly overlapping. We have also added an experimental comparison with VisionReasoner (see Q4), where our method achieves superior performance on the proposed surgical benchmark.\n\nQ4: We thank the reviewer for the valuable comment. Table 1 is not intended as a matched-training comparison. Instead, it follows the standard evaluation protocol adopted by MedReasoner, where existing MLLMs and reasoning segmentation methods are evaluated in their original off-the-shelf setting, while SurgReasoner is trained on SurgSeg-14K. As stated in the manuscript, the purpose of this comparison is two-fold: (1) to evaluate how well existing reasoning segmentation methods generalize to the newly proposed surgical reasoning segmentation benchmark, and (2) to demonstrate the performance achieved by a model specifically optimized for this task.\n\nTo address the reviewer's concern regarding missing baselines, we further evaluated VisionReasoner under the same protocol. VisionReasoner achieves 41.27 Dice, while SurgReasoner achieves 44.78 Dice, demonstrating the effectiveness of our method on the proposed surgical benchmark.\n\nFinally, we emphasize that Table 1 is intended for benchmark comparison rather than optimization comparison. The contribution of our proposed difficulty-aware optimization strategy is instead validated through the controlled ablation study in Table 2, where all variants share the same backbone and differ only in the optimization strategy."+ },+ "createdAt": "2026-08-01T10:39:10.860Z",+ "modifiedAt": "2026-11-19T17:18:42.776Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=RuUvFDXu59",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/ulrlzyia38.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/ulrlzyia38.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "uLRlZYIa38",+ "replyTo": "lTDwd81Op0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Area Chair ZJbS",+ "content": {+ "title": "Discussion",+ "comment": "Please review the rebuttal to assess whether it addressed your concerns, and continue to discuss if needed."+ },+ "createdAt": "2026-08-03T07:01:28.761Z",+ "modifiedAt": "2026-11-19T17:18:42.383Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=uLRlZYIa38",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/x23a1nvcre.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/x23a1nvcre.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "x23A1nvcre",+ "replyTo": "5yx0ZBSHke",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Parameter Sensitivity Analysis",+ "comment": "We preliminarily investigate parameter sensitivity on two randomly selected weighting coefficients ($\\lambda_{\\text{edge}}$ and $\\lambda_{\\text{distance}}$). We vary each target weight within $\\{0.5,1,2\\}$ and fix all other $\\lambda$ values to 1. Experimental results show that mild tuning of these weights only brings slight performance fluctuations. Given that reward weight design is not our core contribution, we omit exhaustive sensitivity tests for all six $\\lambda$ hyperparameters. Detailed results are shown in the following table and added to the revised appendix.\n\n| Configuration | IoU (\\%) | pDice (\\%) | Dice (\\%) |\n| :--- | :---: | :---: | :---: |\n| $\\lambda_{\\text{edge}}=0.5$ | 43.76 | 11.38 | 44.27 |\n| $\\lambda_{\\text{edge}}=1.0$ | 44.22 | 11.66 | 44.78 |\n| $\\lambda_{\\text{edge}}=2.0$ | 43.27 | 11.79 | 44.11 |\n| $\\lambda_{\\text{distance}}=0.5$ | 44.31 | 11.43 | 44.35 |\n| $\\lambda_{\\text{distance}}=1.0$ | 44.22 | 11.66 | 44.78 |\n| $\\lambda_{\\text{distance}}=2.0$ | 44.13 | 11.74 | 44.09 |"+ },+ "createdAt": "2026-08-01T10:44:01.980Z",+ "modifiedAt": "2026-11-19T17:18:42.822Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=x23A1nvcre",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/yllqvpimm2.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/yllqvpimm2.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "yllqvPimm2",+ "replyTo": "rGaVjl6QsT",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer YL3L",+ "content": {+ "title": "Response to Rebuattl",+ "comment": "The authors' response has addressed some of my concerns, but several issues remain.\n\nQ1. The paper does not discuss the novelty compared to existing reasoning segmentation methods, such as VisionReasoner [1]. The methodological framework largely follows the standard reasoning segmentation paradigm, without clearly articulating task‑specific innovations or challenges unique to the medical domain.\n\nQ4. The experimental results show that Medreasoner achieves a substantial performance boost under the matched‑training setting, which raises doubts about the reliability of the results reported in Table 1. Moreover, the comparison lacks many classical and recent reasoning segmentation approaches, including VisionReasoner [1].\n\n[1] Liu Y, Qu T, Zhong Z, et al. Visionreasoner: Unified visual perception and reasoning via reinforcement learning. arXiv:2505.12081, 2025."+ },+ "createdAt": "2026-07-31T11:05:24.603Z",+ "modifiedAt": "2026-11-19T17:18:42.985Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=yllqvPimm2",+ "license": "CC-BY-4.0"+}
reviews/openreview/3s2pcxyuis/notes/yx5yreulr4.json added
+++ b/reviews/openreview/3s2pcxyuis/notes/yx5yreulr4.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "YX5YReuLr4",+ "replyTo": "lTDwd81Op0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer KBi7",+ "content": {+ "comment": "Thank the authors for the clarifications. The response substantially addresses my questions about SurgSeg-14K validation and safety. The 50% stratified manual review, correction and rejection rates, and escalation to clinical experts are useful details. I also appreciate the clarification that the system is not intended for autonomous intraoperative decision-making, but rather for research-oriented applications such as video indexing, education, and retrospective analysis.\n\nMy remaining concerns are mainly about baseline comparability and the practical significance of the implicit-query setting. I encourage the authors to clearly distinguish trained or fine-tuned baselines from off-the-shelf prompting baselines, and to include the full data governance, annotation validation, and safety discussion in the revised manuscript."+ },+ "createdAt": "2026-08-04T10:56:29.779Z",+ "modifiedAt": "2026-11-19T17:18:42.568Z",+ "url": "https://openreview.net/forum?id=3S2PCXYUIS¬eId=YX5YReuLr4",+ "license": "CC-BY-4.0"+}