PIS: Pose-Interpolation Smoothness for Skinning Weight Refinement
Update NeurIPS 2026 submission bfpbtJ168y: 3 notes
@openreview[bot] · 2026-11-24 15:53 UTC · eaaff0409935 ·
reviews/openreview/bfpbtj168y/notes/7n0oqplayq.json added
+++ b/reviews/openreview/bfpbtj168y/notes/7n0oqplayq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "7N0oqPlAyQ",+ "replyTo": "rMRgde9uNM",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer K6o4",+ "content": {+ "comment": "Thanks for the follow-up and detailed explanations. The response addresses my concerns and questions. I will increase my score."+ },+ "createdAt": "2026-08-03T03:31:19.107Z",+ "modifiedAt": "2026-11-19T16:56:39.835Z",+ "url": "https://openreview.net/forum?id=bfpbtJ168y¬eId=7N0oqPlAyQ",+ "license": "CC-BY-4.0"+}
reviews/openreview/bfpbtj168y/notes/7v90tx8zjm.json modified
+++ b/reviews/openreview/bfpbtj168y/notes/7v90tx8zjm.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair GSWU","content": {- "metareview": "The paper proposes Pose-Interpolation Smoothness (PIS), a self-supervised, training-free method for refining linear-blend-skinning weights. PIS encourages the deformation at the midpoint of two poses to match the average deformation at their endpoints, with the goal of reducing twisting, volume collapse, and related animation artifacts without changing the downstream LBS pipeline. The method is evaluated on a non-humanoid-heavy Objaverse-LVIS benchmark and reports improvements across several geometric deformation metrics.\nBased on the reviews the paper is well motivated and clearly presented. The method seems simple and compatible with existing animation pipelines. The reviewers also like the Laplacian, sparsity, ARAP, and pose-generalization analyses.\n\nThe main issues requiring clarification:\n- Is the PIS objective is sufficiently aligned with the visual artifact it is intended to address. As K6o4 notes, even a perfectly rigid rotating point follows a curved trajectory, so a nonzero midpoint residual does not necessarily indicate faulty skinning.\n\n- The lack of a perceptual study or comparison to reference deformations limits how confidently the reported numerical gains can be interpreted as visible improvements.\n\n- It may be needed to do some comparisons to methods such as SkinCells, BBW. The authors should clarify the rationale for the chosen initializers.\n\nFor the paper to be strongly considered, the response should prioritize the following questions:\n\n1) Why does PIS distinguish harmful skinning artifacts from valid rigid rotational motion? \nDoes refinement preserve intended articulation? Please provide any existing evidence based on motion amplitude, endpoint displacement, effective bone usage, clean artist-painted weights, or another motion-preservation diagnostic. Potentially some new benchmarks may also help.\n\n2) How directly do the reported metrics reflect visible animation quality? Qualitative side-by-side examples, reference-based comparisons, or an existing small perceptual evaluation would be helpful. \n\n3) Why is the polar-projection midpoint preferred to a geodesic midpoint? In particular, please clarify whether differentiability through the sampled rotations is actually needed.\n\n4) What claims of generality are supported by the tested initializers and baselines? Please clearly delimit the current scope and mention any already-completed experiments with other predictors or refiners."+ "metareview": "The paper proposes Pose-Interpolation Smoothness (PIS), a self-supervised, training-free method for refining linear-blend-skinning weights. PIS encourages the deformation at the midpoint of two poses to match the average deformation at their endpoints, with the goal of reducing twisting, volume collapse, and related animation artifacts without changing the downstream LBS pipeline. The method is evaluated on a non-humanoid-heavy Objaverse-LVIS benchmark and reports improvements across several geometric deformation metrics.\nBased on the reviews the paper is well motivated and clearly presented. The method seems simple and compatible with existing animation pipelines. The reviewers also like the Laplacian, sparsity, ARAP, and pose-generalization analyses.\n\nThe main issues requiring clarification:\n- Is the PIS objective is sufficiently aligned with the visual artifact it is intended to address. As K6o4 notes, even a perfectly rigid rotating point follows a curved trajectory, so a nonzero midpoint residual does not necessarily indicate faulty skinning.\n\n- The lack of a perceptual study or comparison to reference deformations limits how confidently the reported numerical gains can be interpreted as visible improvements.\n\n- It may be needed to do some comparisons to methods such as SkinCells, BBW. The authors should clarify the rationale for the chosen initializers.\n\nFor the paper to be strongly considered, the response should prioritize the following questions:\n\n1) Why does PIS distinguish harmful skinning artifacts from valid rigid rotational motion? \nDoes refinement preserve intended articulation? Please provide any existing evidence based on motion amplitude, endpoint displacement, effective bone usage, clean artist-painted weights, or another motion-preservation diagnostic. Potentially some new benchmarks may also help.\n\n2) How directly do the reported metrics reflect visible animation quality? Qualitative side-by-side examples, reference-based comparisons, or an existing small perceptual evaluation would be helpful. \n\n3) Why is the polar-projection midpoint preferred to a geodesic midpoint? In particular, please clarify whether differentiability through the sampled rotations is actually needed.\n\n4) What claims of generality are supported by the tested initializers and baselines? Please clearly delimit the current scope and mention any already-completed experiments with other predictors or refiners.",+ "final_justification": "The authors provided a strong and comprehensive rebuttal that directly addressed the main concerns raised by the reviewers. The reviewers indicated that these additions resolved their principal concerns and strengthened their assessments. Overall, the rebuttal strengthens the empirical and methodological support for the work, and I therefore recommend acceptance."},"createdAt": "2026-07-19T22:02:40.329Z",- "modifiedAt": "2026-11-18T15:20:23.967Z",+ "modifiedAt": "2026-11-19T05:00:14.597Z","url": "https://openreview.net/forum?id=bfpbtJ168y¬eId=7V90Tx8Zjm","license": "CC-BY-4.0"}
reviews/openreview/bfpbtj168y/notes/qzv6mjwqtg.json added
+++ b/reviews/openreview/bfpbtj168y/notes/qzv6mjwqtg.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "QZv6mjWqtg",+ "replyTo": "7V90Tx8Zjm",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to the Initial Meta-Review",+ "comment": "We thank the Area Chair for identifying the four decision-critical questions. Our reviewer-specific responses provide the full experimental details; we summarize the main evidence here.\n\n**1. Valid rigid rotation and articulation preservation.** A nonzero PIS residual measures cross-pose curvature and is not, by itself, an artifact label. For a correctly skinned single-bone point, the residual may be nonzero, but the feasible weight simplex contains only $w=1$, so PIS cannot reduce the trajectory radius or suppress the rigid rotation. On 98 UniRig models, PIS preserves 99.93% of global displacement, 99.90% on high-motion vertices, 99.88% in blend regions, and 99.95% at part centroids; the motion-direction cosine is 0.9986 and the activity-weighted attachment ratio is 0.9998.\n\n**2. Visible animation quality and reference motion.** In a randomized, blinded study with 25 participants and 25 animation pairs, 5 assets favor PIS for both artifact quality and overall animation quality, none favor the initializer, and 20 are ties; all 25 articulation comparisons are ties. On 270 artist-painted RigNet rigs, global and part-centroid motion amplitudes change by at most 0.08%, while high-motion amplitude and the median direction cosine remain 1.0000; trajectory NRMTE is 0.033. Case-level analysis links the four high-confidence perceptual wins to the removal of holes, truncation, jagged boundaries, and persistent creases without evident motion suppression.\n\n**3. Polar versus geodesic midpoint.** Differentiability through the sampled rotations is not required. Under our bounded-angle sampling, the polar factor is a proper, endpoint-symmetric batched realization of the same geodesic midpoint. Across 10,000 sampled rotation pairs, its maximum discrepancy from the log-exp midpoint is $2.98 \\times 10^{-8}$ rad.\n\n**4. Generality and baselines.** Without retraining or predictor-specific changes, PIS improves all five deformation metrics on RigAnything (20 assets/10 categories) and Make-It-Animatable (8 assets/4 categories). On the same 20 meshes from 10 categories, PIS has lower median normalized error than SkinCells on all five metrics, although the paired differences are not statistically significant; we therefore claim competitive, not superior, performance. Volumetric BBW produces valid outputs on only 6/98 generated meshes, so we report applicability rather than a full paired deformation-quality comparison. PIS also improves all five aggregate metrics on the 9/20 meshes for which Blender Automatic Weights returns usable weights.\n\nWe will correspondingly narrow the paper's claims: PIS refines weights for a fixed skeleton, does not correct skeleton topology or placement errors, and incurs a one-time offline refinement cost while leaving the runtime LBS pipeline unchanged."+ },+ "createdAt": "2026-07-29T00:21:10.700Z",+ "modifiedAt": "2026-11-19T16:56:39.151Z",+ "url": "https://openreview.net/forum?id=bfpbtJ168y¬eId=QZv6mjWqtg",+ "license": "CC-BY-4.0"+}