potentialpaper

MedCache: Training-Free Spatially Aware Caching for Accelerated Medical Video Generation

Update NeurIPS 2026 submission nJdSfl9uaK: 12 notes

@openreview[bot] · 2026-11-24 15:55 UTC · 43cd78bcb7e0 ·

Evidence

reviews/openreview/njdsfl9uak/notes/3punmc4x6z.json added

+++ b/reviews/openreview/njdsfl9uak/notes/3punmc4x6z.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "3PUnmC4X6z",
+ "replyTo": "9kY13GO5U3",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Follow-up to Reviewer T1q5",
+ "comment": "Dear ***Reviewer T1q5***,\n\nAs the discussion period is nearing its end, we would like to kindly follow up and ask whether you have any additional questions, concerns, or requests for clarification regarding our response. We hope the additional cue-subset ablations, alternative spatial-energy and fusion controls, and clarification of the WAN2.1 speed-quality trade-off addressed your concerns. Please let us know if any point would benefit from further clarification. We would be happy to provide further explanation or additional evidence that may help address any remaining concerns. We sincerely appreciate the time and effort you have invested in reviewing our work and thank you for your thoughtful feedback.\n\nThank you again for your consideration."
+ },
+ "createdAt": "2026-08-01T11:59:42.611Z",
+ "modifiedAt": "2026-11-19T16:49:18.905Z",
+ "url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=3PUnmC4X6z",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/njdsfl9uak/notes/8e6sasflix.json added

+++ b/reviews/openreview/njdsfl9uak/notes/8e6sasflix.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "8e6SAsFLIX",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Follow-up to All Reviewers and Area Chair",
+ "comment": "Dear Reviewers and Area Chair,\n\nAs the discussion period approaches its conclusion in less than 24 hours, we would like to kindly follow up on our rebuttal and the additional experimental evidence provided in response to your comments.\n\nWe have addressed the questions concerning hyperparameter robustness, component contributions, the prompt prior, spatial-risk estimation, localized fidelity, risk-map stability, and cross-model generalization. We have also clarified the transcription error in the paper's ablation table and explained its scope.\n\nWe would be grateful to know whether our responses have addressed your main concerns or whether any questions remain. We would be happy to provide further clarification during the remaining discussion period. We hope that the clarifications and additional evidence provided during the discussion period will be considered in the final assessment of ***MedCache***.\n\nThank you again for your time, careful evaluation, and constructive feedback."
+ },
+ "createdAt": "2026-08-03T13:28:15.719Z",
+ "modifiedAt": "2026-11-19T16:49:18.505Z",
+ "url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=8e6SAsFLIX",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/njdsfl9uak/notes/8wsjndgcgv.json added

+++ b/reviews/openreview/njdsfl9uak/notes/8wsjndgcgv.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "8WSJnDgcGv",
+ "replyTo": "O6cKEmoisR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear ***Reviewer eDhA***,\n\nAs the discussion period is nearing its end, we would like to kindly follow up and ask whether you have any additional questions, concerns, or requests for clarification regarding our response.\n\nWe hope our clarification of the corrected Table 3 entries, the roles of the individual components, and the additional threshold-scale experiment addressed your concerns. Please let us know if any point remains unclear or if further explanation would be helpful. \n\nWe would be happy to provide further explanation or additional evidence that may help address any remaining concerns. We sincerely appreciate the time and effort you have invested in reviewing our work and thank you for your thoughtful feedback.\n\nThank you again for your consideration.",
+ "title": "Follow-up to Reviewer eDhA"
+ },
+ "createdAt": "2026-08-01T11:56:58.896Z",
+ "modifiedAt": "2026-11-19T16:49:18.944Z",
+ "url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=8WSJnDgcGv",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/njdsfl9uak/notes/ctxwcvuckm.json modified

+++ b/reviews/openreview/njdsfl9uak/notes/ctxwcvuckm.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair cjD3",
"content": {
- "metareview": "The paper presents a training-free approach for speeding up medical video generation by leveraging the latent space and image processing operators. The paper received an initial review of 3,3,4. The reviewers generally appreciated the idea of skipping inference steps using latents themselves, leading to substantial improvement in speed and quality. However, the reviewers still have many questions and concerns that the authors should address during the rebuttal.\n\nThe AC notes the primary concerns that came out of this discussion:\n(1) The proposed method seems to be very general, so why is the paper focused on medical video generation? What is specific about the technique that is related to medical video? \n(2) There are significant concerns about the large number of hyperparameters and heuristics-based design choices in the approach, and no systematic study indicating how robust and important these choices and settings are, raising concerns of a potential AI-generated method. Authors are strongly encouraged to read and respond to R-jVDu’s (Q 1-4), R-T1q5’s (Q 1), and R-eDhA’s concerns about the lack of many ablation studies.\n\nOverall, the AC feels the current version of the paper has a large number of hyperparameter and heuristic-driven design choices, which have neither been conceptually explained nor empirically validated, and lacks a concrete connection to the medical domain. The rebuttal should try to address these critical concerns.\n\nAfter the rebuttal, the score of the paper is 4,4,5. The rebuttal mostly addressed the 2 main concerns regarding the scope of the paper (Why medical videos) and the heuristic-driven design choices and their robustness. The AC recommends the paper for acceptance. However, the AC notes that the paper requires significant revisions, primarily to motivate the medical focus better and clarify the design choices. The supplementary material should include more robustness analysis and additional experiments presented in the rebuttal. The AC would also ask the authors to maintain brevity in any additional experiments included in the paper/supplementary. The rebuttal was particularly long and verbose which could have been more succint."
+ "metareview": "The paper presents a training-free approach for speeding up medical video generation by leveraging the latent space and image processing operators. The paper received an initial review of 3,3,4. The reviewers generally appreciated the idea of skipping inference steps using latents themselves, leading to substantial improvement in speed and quality. However, the reviewers still have many questions and concerns that the authors should address during the rebuttal.\n\nThe AC notes the primary concerns that came out of this discussion:\n(1) The proposed method seems to be very general, so why is the paper focused on medical video generation? What is specific about the technique that is related to medical video? \n(2) There are significant concerns about the large number of hyperparameters and heuristics-based design choices in the approach, and no systematic study indicating how robust and important these choices and settings are, raising concerns of a potential AI-generated method. Authors are strongly encouraged to read and respond to R-jVDu’s (Q 1-4), R-T1q5’s (Q 1), and R-eDhA’s concerns about the lack of many ablation studies.\n\nOverall, the AC feels the current version of the paper has a large number of hyperparameter and heuristic-driven design choices, which have neither been conceptually explained nor empirically validated, and lacks a concrete connection to the medical domain. The rebuttal should try to address these critical concerns.\n\nAfter the rebuttal, the score of the paper is 4,4,5. The rebuttal mostly addressed the 2 main concerns regarding the scope of the paper (Why medical videos) and the heuristic-driven design choices and their robustness. The AC recommends the paper for acceptance. However, the AC notes that the paper requires significant revisions, primarily to motivate the medical focus better and clarify the design choices. The supplementary material should include more robustness analysis and additional experiments presented in the rebuttal. The AC would also ask the authors to maintain brevity in any additional experiments included in the paper/supplementary. The rebuttal was particularly long and verbose which could have been more succint.",
+ "final_justification": "After the rebuttal, the score of the paper is 4,4,5. The rebuttal mostly addressed the 2 main concerns regarding the scope of the paper (Why medical videos) and the heuristic-driven design choices and their robustness. The AC recommends the paper for acceptance."
},
"createdAt": "2026-07-15T18:08:10.127Z",
- "modifiedAt": "2026-11-18T15:20:39.209Z",
+ "modifiedAt": "2026-11-19T05:00:25.462Z",
"url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=CtXwCVuckm",
"license": "CC-BY-4.0"
}

reviews/openreview/njdsfl9uak/notes/i2dedgjgbz.json added

+++ b/reviews/openreview/njdsfl9uak/notes/i2dedgjgbz.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "I2DEDGJGbz",
+ "replyTo": "rKyfD2YWVk",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Author Response to Area Chair cjD3: Robustness, Medical Motivation, and Localized Cache Fidelity (2/2)",
+ "comment": "### 3. Broad speed-quality results\n\nTables 1 and 2 establish the overall efficiency-quality behavior across models and tasks. At their reported operating points, MedCache achieves both higher speedup and higher Total than WorldCache in six of the eight model-task blocks. The two exceptions are the WAN2.1 settings, where MedCache provides substantially greater acceleration with a small reduction in Total. We therefore interpret those results as a more aggressive speed-quality operating point rather than evidence that MedCache universally dominates every baseline. Aggregate video-level metrics, however, do not directly determine whether caching preserves a small annotated surgical structure. A method may retain a strong aggregate Total while still introducing substantial local deviation around an instrument or anatomical boundary.\n\nWe therefore conducted two additional analyses.\n\nFirst, at the dataset level, the top 10% of spatial locations selected by the MedCache risk map contain 27.12% [26.99, 27.25] of the latent drift across the 300-video Cosmos-H-Surgical Image2World evaluation. This confirms that the representative example in Figure 2b reflects a broader concentration pattern rather than a single isolated case. Second, we conducted a localized cache-fidelity analysis around annotated surgical structures.\n\n### 4. Localized cache-fidelity analysis\n\nWe evaluated the CholecT50 Image2World samples for this analysis. It does not alter generation, train any component, or tune MedCache. For each case, we compare the cached rollout with the uncached rollout generated using the same prompt, conditioning image, and random seed. The uncached rollout is used as the reference trajectory, not as a claim of clinical ground truth. We exclude the conditioning frame and evaluate generated frames 1-16, corresponding to the first post-conditioning second.\n\nThe SurgSigma instrument annotation in the conditioning image defines a fixed **instrument-anchor region**. A one-pixel morphological boundary of that annotation defines the **instrument-boundary band**. Because these are fixed conditioning-frame regions rather than per-frame tracked segmentations, the analysis measures whether early cached trajectories remain faithful around the original surgical structure.\n\nWe compute the mean absolute decoded RGB difference on the standard 0-255 intensity scale. Lower MAE means that the cached trajectory remains closer to the same-seed uncached trajectory in the evaluated region. Confidence intervals are obtained through paired bootstrap resampling over the 260 cases.\n\n| Evaluated region | WorldCache MAE | MedCache MAE | Absolute MAE reduction, 95% CI |\n| ---------------------------------- | -------------: | -----------: | -----------------------------: |\n| Complete frame | 16.539 | 8.030 | 8.509 [7.897, 9.149] |\n| Instrument anchor, 7.42% of frame | 32.534 | 13.699 | 18.835 [17.247, 20.540] |\n| One-pixel instrument-boundary band | 31.005 | 13.723 | 17.283 [15.954, 18.671] |\n\nAlthough the instrument-anchor region occupies only 7.42% of the frame, cache-induced deviation within it is substantially larger than the full-frame average. This demonstrates why aggregate frame-level metrics can underrepresent localized cache failures. Relative to WorldCache, MedCache reduces MAE by **57.9% in the instrument-anchor region** and **55.7% along the instrument boundary**. The paired confidence intervals for the absolute reductions exclude zero.\n\nThese results directly support the medical motivation: MedCache remains substantially closer to the uncached trajectory around a small annotated surgical region than the compared probe-based baseline.\n\nWe emphasize that this analysis is a diagnostic of **localized cache fidelity**. It does not establish anatomical correctness, procedural correctness, clinical validity, or per-frame instrument segmentation. Its purpose is to isolate the sparse local deviations that motivated the design of MedCache."
+ },
+ "createdAt": "2026-08-02T09:00:09.896Z",
+ "modifiedAt": "2026-11-19T16:49:18.898Z",
+ "url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=I2DEDGJGbz",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/njdsfl9uak/notes/jnbi8bbrpx.json added

+++ b/reviews/openreview/njdsfl9uak/notes/jnbi8bbrpx.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "JNbi8bBRPx",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Area Chair cjD3",
+ "content": {
+ "title": "Reviewers: Please check the rebuttal",
+ "comment": "Dear Reviewers,\n\nWe are reaching the end of the rebuttal/discussion period. Can you please check the author responses and let us know if the rebuttal addresses your concerns? Please let the authors know if you have any additional concerns (please avoid requests for heavy experiments due to lack of time).\n\nThank you, R-jVDu, for checking the rebuttal and initiating a discussion with the authors.\n\nAC."
+ },
+ "createdAt": "2026-08-02T21:55:23.482Z",
+ "modifiedAt": "2026-11-19T16:49:18.540Z",
+ "url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=JNbi8bBRPx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/njdsfl9uak/notes/mghonfw8qm.json added

+++ b/reviews/openreview/njdsfl9uak/notes/mghonfw8qm.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "MGhoNFW8QM",
+ "replyTo": "y9YDvu48Fu",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Clarification of the Corrected Component Ablation",
+ "comment": "We thank ***Reviewer jVDu*** for the thoughtful follow-up and for confirming that the additional sensitivity analyses address the main concerns. We also appreciate the reviewer’s consideration of the component ablation and the opportunity to clarify the apparent reversal between the submitted Table 3 and our rebuttal.\n\nAs detailed in our response to Reviewer **eDhA, Point 2**, the discrepancy was caused by a transcription error in the submitted Table 3, not by a different prompt subset, a modified implementation, or a change in the evaluation protocol. During preparation of the submitted table:\n\n* the speedup and skip-rate values for configurations B and C were interchanged; and\n* the intervention scale was mistakenly written as $\\sigma=0.70$ instead of the intended $\\sigma=1.25$.\n\nThe corrected ablation is:\n\n| Configuration | Speedup | Skip rate | IQ | Total |\n| ------------------------------------ | -----------: | --------: | ------: | ------: |\n| Uncached reference | $1.00\\times$ | -- | $0.610$ | $0.844$ |\n| A: EasyCache | $1.39\\times$ | -- | $0.594$ | $0.840$ |\n| B: + risk-weighted drift, $\\sigma=1$ | $2.37\\times$ | $61.1%$ | $0.593$ | $0.840$ |\n| C: + prompt prior, $\\sigma=1.25$ | $2.52\\times$ | $64.0%$ | $0.593$ | $0.840$ |\n| D: + lazy consistency guard | $2.52\\times$ | $64.0%$ | $0.612$ | $0.846$ |\n\nThe correct component-level interpretation is therefore:\n\n* **A to B:** Risk-weighted spatial drift provides the main acceleration gain, increasing speedup from $1.39\\times$ to $2.37\\times$ while preserving Total at $0.840$.\n* **B to C:** The prompt prior makes a smaller operating-point adjustment, increasing speedup from $2.37\\times$ to $2.52\\times$ and skip rate from $61.1%$ to $64.0%$, with Total unchanged.\n* **C to D:** The lazy guard improves fidelity at the same speedup and skip rate, increasing IQ from $0.593$ to $0.612$.\n\nWe also did an additional experiment just as an independent check, and this post-submission fixed-sample experiment reproduces both the direction and approximate magnitude of the prior’s effect. Increasing $\\sigma$ from $1.00$ to $1.25$ raises speedup from $2.339\\times$ to $2.495\\times$, a relative improvement of $6.7%$, compared with the $6.3%$ increase from $2.37\\times$ to $2.52\\times$ in the corrected Table 3.\n\n| $\\sigma$ | Latency per sample, $95%$ CI | Speedup | Skip rate | Total |\n| -------: | ---------------------------: | ------------: | --------: | -------: |\n| No cache | $52.4$ s $[51.9,53.1]$ | $1.000\\times$ | $0.00%$ | $0.8517$ |\n| $0.70$ | $26.0$ s $[24.8,27.0]$ | $2.015\\times$ | $54.86%$ | $0.8473$ |\n| $1.00$ | $22.4$ s $[21.6,23.3]$ | $2.339\\times$ | $62.29%$ | $0.8454$ |\n| $1.25$ | $21.0$ s $[20.2,21.9]$ | $2.495\\times$ | $65.43%$ | $0.8499$ |\n| $1.70$ | $19.3$ s $[18.8,20.0]$ | $2.715\\times$ | $68.86%$ | $0.8459$ |\n\nThis correction affects only the interchanged efficiency entries and the incorrect $\\sigma$ label in the submitted component-ablation table. It does not affect the evaluated prompt subset, implementation, generated outputs, quality scores, main comparison tables, or conclusions of the other experiments.\n\nIn the revision, we will correct Table 3 and present the prompt prior as an optional operating-point heuristic, while identifying the prompt-agnostic risk-weighted spatial controller as the core contribution."
+ },
+ "createdAt": "2026-07-31T06:13:28.161Z",
+ "modifiedAt": "2026-11-19T16:49:19.300Z",
+ "url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=MGhoNFW8QM",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/njdsfl9uak/notes/oi2e7su8zd.json added

+++ b/reviews/openreview/njdsfl9uak/notes/oi2e7su8zd.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "OI2e7Su8zD",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Summary of Rebuttal Clarifications and Additional Cross-Transfer Evidence",
+ "comment": "Dear ***Reviewers and Area Chair***,\n\nThank you again for the careful reviews and constructive questions. To facilitate the final assessment, we briefly summarize the main clarifications and additional evidence provided during the discussion.\n\n1. **MedCache does not require per-model or per-task controller tuning**. All controller parameters were selected once on a disjoint development split and then frozen across the reported models and tasks. The additional one-dimensional sweeps, seven-factor joint perturbation study, and seed analysis show smooth speed–quality behavior and no interaction collapse. Across $40$ tested cache configurations, every setting retained at least $2.4\\times$ speedup, where $38/40$ remained within $0.005$ Total of the configuration and all $40/40$ remained within $0.01$.\n\n2. We clarified the **role of the prompt prior**. The prompt-agnostic risk-weighted controller is the core method, while the keyword prior is only an optional operating-point adjustment. A keyword miss falls back to $\\sigma=1$ and does not disable caching, alter the spatial-risk map, or assign an unsupported semantic category. We will revise the paper to present the prior as an optional heuristic rather than a central component.\n\n3. We provided **dataset-level evidence for the spatial-risk map**. Across the complete Cosmos-H-Surgical Image2World evaluation, the highest-risk $10%$ of locations contain $27.12%$ of the observed latent drift, compared with a $10%$ uniform expectation. The same concentration pattern holds across selected supports from $1%$ to $12%$. On localized CholecT50 instrument regions, MedCache reduces cache-induced MAE relative to WorldCache by $57.9%$ within the instrument region and $55.7%$ along its boundary.\n\n4. We quantified **risk-map staleness**. Cached maps remain highly similar to freshly computed diagnostic maps, with cosine similarity of $0.9724$ on Cosmos-Predict Text2World and $0.9906$ on the full Cosmos-H-Surgical Image2World evaluation. Controlled refresh-delay stress tests reduce map agreement as expected, but even delaying refresh to every fourth full computation changes VBench Total by less than $0.0002$.\n\n5. We clarified the **component ablation correction**. The apparent reversal in submitted Table 3 was caused by a transcription error: the speedup and skip-rate entries for configurations B and C were interchanged, and configuration C was labeled $\\sigma=0.70$ instead of the intended $\\sigma=1.25$. No prompt subset, implementation, generated output, quality score, or main comparison result changed. The corrected interpretation is that risk-weighted spatial drift provides the main gain from $1.39\\times$ to $2.37\\times$, the prior adjusts the operating point from $2.37\\times$ to $2.52\\times$, and the guard improves fidelity at fixed efficiency.\n\n6. We clarified that the **risk estimator is not dependent on one uniquely optimal filter or fusion rule**. Alternative local-variance energy produced nearly identical results, and parameter-free nonlinear fusion did not yield a statistically resolved quality improvement. The S-F-M cues should therefore be interpreted as a simple, complementary, and training-free spatial basis rather than three individually indispensable components.\n\n---\n### ***Additional transfer evaluation on MedGen-1.3B***\n---\n\nTo further examine generalization beyond the reported checkpoints, we added a controlled comparison between the generic WAN2.1-1.3B checkpoint and **MedGen-1.3B**, a medically adapted model initialized from the same architecture. The architecture, sampler, prompts, resolution, denoising steps, random seed, MedCache configuration, and quality-oriented threshold were held fixed. No checkpoint-specific controller tuning was performed.\n\n|Checkpoint| Method| Speedup | Skip rate | SSIM | VBench Total | Total change, $95%$ CI |\n| - | - | -: | -: | -: | -: | -: |\n|WAN2.1-1.3B|No-cache |$1.00\\times$ |$0.0%$ | $1.0000$ | $0.89315$ | -- |\n|WAN2.1-1.3B|MedCache | **$2.48\\times$**| $56.5%$ | $0.96$ |**$0.89335$** |$+0.00019$ $[-0.00074,0.00115]$ |\n|MedGen-1.3B|No-cache | $1.00\\times$ | $0.0%$ | $1.0000$ | $0.88449$ | -- |\n|MedGen-1.3B|MedCache | **$2.47\\times$**| $54.6%$ | $0.98$ |**$0.88280$** |$-0.00169$ $[-0.00363,0.00001]$ |\n\nMedCache achieves nearly identical acceleration on the generic and medically adapted checkpoints: $2.48\\times$ and $2.47\\times$, respectively. Same-seed similarity to no-cache generation also remains high. WAN2.1 Total is effectively unchanged, while MedGen shows a small observed reduction whose paired $95%$ confidence interval includes zero. We also evaluated the same more aggressive shared operating point, obtaining $3.05\\times$ speedup on WAN2.1 and $3.02\\times$ on MedGen. No checkpoint-specific controller redesign or parameter fitting was used.\n\n---\n***We will incorporate these clarifications, corrected tables, additional analyses, and more precise scope statements in the revision.***\n\n---"
+ },
+ "createdAt": "2026-08-04T11:06:18.415Z",
+ "modifiedAt": "2026-11-19T16:49:18.468Z",
+ "url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=OI2e7Su8zD",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/njdsfl9uak/notes/rkyfd2ywvk.json added

+++ b/reviews/openreview/njdsfl9uak/notes/rkyfd2ywvk.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "rKyfD2YWVk",
+ "replyTo": "CtXwCVuckm",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Author Response to Area Chair cjD3: Robustness, Medical Motivation, and Localized Cache Fidelity (1/2)",
+ "comment": "We thank the Area Chair **cjD3** and reviewers for their careful and constructive feedback. We appreciate that Reviewer **eDhA** found the central insight compelling and the presentation clear, Reviewer **jVDu** viewed the probe-free spatial design as a useful and non-obvious contribution with encouraging results across multiple model families, and Reviewer **T1q5** recognized the value of spatially selective reuse when video dynamics are structured and localized. We also appreciate the Area Chair’s summary that the reviewers broadly valued the idea of using the latent representation itself to guide cache reuse and improve the speed-quality trade-off. The main concerns are similarly consistent across the reviews: whether the method is robust despite its heuristic design choices and numerical constants, and whether the medical-video focus is sufficiently justified for a technique whose underlying operators are general. We address these two concerns directly below.\n\n## 1. Robustness and parameter selection: \nMedCache was not tuned separately for each model, task, or evaluation setting. As described in Supplementary Section A.6, all controller parameters were selected once on a held-out Text2World development split, frozen before evaluation, and transferred unchanged to all reported experiments, including Image2World. The denoising schedule, guidance scale, and output resolution vary only where required by the native sampling protocol of the underlying generator. These are backbone settings rather than MedCache parameters.\n\nSupplementary Section D.4 and Figures 10-11 already report sensitivity analyses for the principal speed-quality parameters, $\\tau$, $\\beta$, and $\\kappa$, in the Image2World setting. These sweeps show smooth operating-point changes for $\\tau$ and $\\kappa$, while $\\beta$ lies in a broad, nearly flat region rather than at a sharply selected optimum.\n\nTo cover the remaining constants and possible interactions, we additionally provide a thorough robustness study, reported in detail in our response to Reviewer **jVDu**. Across these configurations, every setting retained at least (2.4x) speedup; 38/40 remained within 0.005 Total of the frozen configuration, and all 40/40 remained within 0.01. An eight-run joint perturbation study varying seven constants simultaneously also showed no interaction collapse. These results support the interpretation that MedCache has a low-dimensional speed-quality boundary rather than a collection of independently fitted corrective knobs.\n\nWe will also revise the paper to make the contribution hierarchy explicit, i.e.,\n* The core contribution is the **probe-free, latent-derived spatial cache criterion**.\n* Prompt-based threshold modulation is an optional operating-point adjustment (**Reviewer jVDu**).\n* The lazy consistency guard is an optional fidelity safeguard near the cache-decision boundary.\nThis revised framing separates the central mechanism from auxiliary controls that do not independently define the skip budget.\n\n## 2. Why focus on medical video? \nThe operators used by MedCache are intentionally general. We do not claim that Sobel gradients, Laplacian energies, or relative latent differences are inherently medical. The medical motivation instead comes from the failure regime being addressed.\n\nIn many medical videos, visually and procedurally important changes are spatially sparse. Examples include a tool-tissue contact point, vessel boundary, imaging interface, or lesion edge. Because such a region may occupy only a small fraction of the frame, a global drift average can assign it little influence even when a local cache error is highly visible or consequential. MedCache addresses this asymmetry by estimating **where residual reuse is risky**, rather than treating all spatial locations equally.\n\nTo the best of our knowledge, this is the first systematic study of training-free inference caching specifically for diffusion or rectified-flow-based medical video generation. Existing medical-video work primarily develops datasets, generation architectures, and domain-specific checkpoints, whereas prior cache controllers such as EasyCache, TeaCache, and WorldCache have been designed and evaluated mainly on general visual benchmarks.\n\nMedCache connects these two research directions by asking:\n\n> Can video-generation inference be accelerated without allowing a globally small cache error to produce a large deviation in a small, medically relevant structure?\n\nThis is also the intended meaning of the name ***MedCache***. It identifies the motivating failure regime and primary validation setting. Also, it does not imply that the underlying operators are restricted to medicine. Generic applicability is therefore a positive transfer property rather than a contradiction. The submitted paper already evaluates this transfer on HunyuanVideo in Table 6 and explicitly limits its strongest claims to medical and image-conditioned regimes in Supplementary Section F."
+ },
+ "createdAt": "2026-08-02T08:59:00.732Z",
+ "modifiedAt": "2026-11-19T16:49:18.662Z",
+ "url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=rKyfD2YWVk",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/njdsfl9uak/notes/tv4w7z0cnp.json added

+++ b/reviews/openreview/njdsfl9uak/notes/tv4w7z0cnp.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "tv4w7Z0Cnp",
+ "replyTo": "emjpgGA0by",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Extended Quantitative Validation of MedCache Tables Discussed in Rebuttal",
+ "comment": "## Q1. Joint perturbation study\n\n| Joint runs | $\\tau$ | $\\kappa$ | Reuse | Speedup | Total | PSNR | SSIM |\n| - | -: | -: | -: | -: | -: | -: | -: |\n| J1-J2 | $0.0855$ | $1.05$ | $33.29$-$33.57%$ | $2.452$-$2.458x$ | $0.8595$-$0.8600$ | $26.097$-$26.182$ | $0.8971$-$0.8986$ |\n| J3-J4 | $0.0855$ | $1.15$ | $41.29$-$41.86%$ | $2.628$-$2.642x$ | $0.8535$-$0.8543$ | $24.255$-$24.390$ | $0.8659$-$0.8682$ |\n| J5-J6 | $0.1045$ | $1.15$ | $46.71$-$47.57%$ | $2.773$-$2.798x$ | $0.8507$-$0.8514$ | $22.198$-$22.618$ | $0.8224$-$0.8337$ |\n| J7-J8 | $0.1045$ | $1.05$ | $40.29$-$40.57%$ | $2.603$-$2.610x$ | $0.8555$-$0.8558$ | $24.022$-$24.124$ | $0.8642$-$0.8666$ |\n\nHere, conservative boundaries remain closer to the uncached output, aggressive boundaries increase reuse and speed, and no interaction collapse is observed.\n\n---\n\n## Q2. Separating the prior from the spatial-cache core\n\n| Configuration | Speedup | Skip rate | Total | Increment tested |\n| -- | --: | --: | --: | -- |\n| EasyCache | $1.39x$ | -- | $0.840$ | Scalar-drift starting point |\n| + risk-weighted drift, neutral prior | $2.37x$ | $61.1%$ | $0.840$ | Prompt-agnostic MedCache core |\n| + prompt prior | $2.52x$ | $64.0%$ | $0.840$ | Threshold modulation only |\n\nThe corrected component ablation provides the most direct separation b/w prior and core method (**eDhA**). Replacing scalar drift with risk-weighted spatial drift produces the main improvement, increasing speedup from 1.39× to 2.37× while preserving Total at 0.840. Enabling the prompt prior then moves the same from 2.37× to 2.52× with Total unchanged. These results show that the prior is not the source of the spatial signal or the primary acceleration gain. It provides a smaller, context-dependent adjustment to the operating point, while the prompt-agnostic latent-risk mechanism remains the core contribution. \n\n---\n\n## Q3. Concentration across support sizes\n\n| Selected area | Uniform expectation | Drift selected by MedCache |\n| --: | --: | --: |\n| $1%$ | $1.00%$ | $6.28%$ $[6.26,6.30]$ |\n| $5%$ | $5.00%$ | $14.21%$ $[14.13,14.28]$ |\n| $10%$ | $10.00%$ | $27.12%$ $[26.99,27.25]$ |\n| $12%$ | $12.00%$ | $32.42%$ $[32.27,32.57]$ |\n\nAlmost same concentration pattern as of single sample is present at every tested support size on the full $300$-video Cosmos-H-Surgical Image2World evaluation.\n\n---\n\n## Q3. Localized surgical-region fidelity\n\n| Region, MAE | WorldCache | MedCache | Reduction with MedCache |\n| -- | --: | --: | --: |\n| Instrument region | $32.534$ | $13.699$ | $57.9%$ |\n| Instrument boundary | $31.005$ | $13.723$ | $55.7%$ |\n\nThe fixed instrument region occupies only $7.42%$ of the frame on average, yet MedCache substantially reduces cache-induced deviation around the instrument and its boundary relative to WorldCache. This is a localized fidelity diagnostic.\n\n---\n\n## Q4. Risk-map age and similarity\n\nWe computed the risk map that would be obtained at every eligible decision and compared it with the map actually cached by MedCache. This diagnostic map was never input to the controller, so it did not affect any skip decision or generated video, and its cost is excluded from all reported latency measurements. We report two interpretable measures: (i) cosine similarity between the complete soft maps, where 1 indicates identical maps, and (ii) IoU between their top-12% regions, where 1 indicates identical high-risk support. Map age is the number of conditional denoising decisions since the last refresh. MedCache does not impose a separate age threshold, so the maximum ages below are observed values rather than theoretical bounds.\n\n| Model | Decisions | Mean age | $95$th-percentile age | Maximum age | Map cosine | Top-$12%$ IoU |\n| - | -: | -: | -: | -: | --: | --: |\n| Cosmos-Predict-2.5 2B, T2W ($20$ vids) | $540$ | $2.08$ | $5$ | $11$ | $0.9724$ $[0.9700,0.9747]$ | $0.5677$ $[0.5476,0.5882]$ |\n| Cosmos-H-Surgical 2B, I2W ($300$ vids) | $8{,}100$ | $3.22$ | $8$ | $16$ | $0.9906$ $[0.9904,0.9909]$ | $0.7107$ $[0.7056,0.7159]$ |\n\nCached soft risk maps remain highly similar to freshly computed maps. The lower top-$12%$ IoU shows that locations near the ranking boundary can change during a skip streak, even though the overall soft map remains stable. We will state this explicitly rather than implying that the high-risk support is invariant.\n\n---\n\n## Q4. Controlled refresh-delay stress test\n\n| Refresh after every $N$ full computations | Mean age | $95$th-percentile age | Maximum age | Map cosine | Top-$12%$ IoU | VBench Total |\n| - | -: | -: | -: | -: | -: | -: |\n| $N=1$, paper | $2.08$ | $5$ | $11$ | $0.9724$ | $0.5677$ | $0.8570$ |\n| $N=2$, stress test| $3.16$ | $8$ | $14$ | $0.9688$ | $0.5242$ | $0.8570$ |\n| $N=4$, stress test | $5.07$ | $12$ | $20$ | $0.9587$ | $0.4593$ | $0.8568$ |\n\nDelaying refresh predictably reduces map similarity, but even the $N=4$ stress test changes Total by less than $0.0002$. The submitted $N=1$ policy is retained because it is the most conservative."
+ },
+ "createdAt": "2026-07-29T07:08:21.857Z",
+ "modifiedAt": "2026-11-19T16:49:18.933Z",
+ "url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=tv4w7Z0Cnp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/njdsfl9uak/notes/vsgrm8tbvl.json added

+++ b/reviews/openreview/njdsfl9uak/notes/vsgrm8tbvl.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "vSGRM8tbVl",
+ "replyTo": "MGhoNFW8QM",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Follow-up on Rebuttal",
+ "comment": "Dear ***Reviewer jVDu***,\n\nThank you again for your thoughtful follow-up and for indicating that the additional analyses addressed most of your concerns. We have now clarified the remaining discrepancy in the component ablation, including the transcription error in Table 3 and its scope.\n\nAs the discussion period is nearing its end, we wanted to ask whether this clarification has resolved your remaining concern. If so, we would be grateful if you could consider updating your assessment accordingly. Of course, please let us know if any point remains unclear or requires further evidence.\n\nThank you again for your time and careful consideration."
+ },
+ "createdAt": "2026-08-02T16:12:49.156Z",
+ "modifiedAt": "2026-11-19T16:49:18.591Z",
+ "url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=vSGRM8tbVl",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/njdsfl9uak/notes/y9ydvu48fu.json added

+++ b/reviews/openreview/njdsfl9uak/notes/y9ydvu48fu.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "y9YDvu48Fu",
+ "replyTo": "tv4w7Z0Cnp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer jVDu",
+ "content": {
+ "title": "Answer to rebuttal",
+ "comment": "Thank you for the detailed response and running additional experiments! These results pretty much address my main concern regarding the hyperparameter issue and whether the reported operating point depends on extensive per-model or per-task tuning. I appreciate the clarification that all MedCache parameters were selected once on a disjoint Text2World development split and then transferred unchanged across models and tasks. I also see that this protocol was already stated in Supplement A.6. The additional one-dimensional sweeps, joint perturbation study, and seed analysis provide well enough evidence that the method is not relying on a narrowly tuned configuration. In particular, the absence of an interaction collapse when varying seven constants simultaneously is good to see.\n\nThe prompt-prior clarification is also helpful. The new ablation indicates that the prompt agnostic risk weighted controller provides the majority of the acceleration gain, while the keyword prior only makes a smaller adjustment to the operating point. I think the revised paper should present the prior as an optional heuristic rather than as a central component of the method, especially since unsupported domains such as ultrasound and dermatology fall back to the neutral setting.\n\nI have one important clarification regarding the corrected component ablation (Maybe I see this wrong or it is just a typo). In the submitted Table 3, adding risk weighting increases speedup from 1.39x to 2.52x, while subsequently adding the domain prior reduces it from 2.52x to 2.37x. However, the rebuttal reports the prompt-agnostic core at 2.37x and states that adding the prior increases it to 2.52x. Could the authors clarify what caused this reversal? Was the submitted table mislabeled, was the corrected experiment evaluated on a different prompt subset, or was there an implementation issue? Please also clarify whether this correction affects any other results or interpretations in the submitted paper.\n\nOverall, the additional evidence addresses most of my concerns. My remaining concern is mainly the discrepancy between the submitted and corrected component ablations, which should be explained clearly in the discussion and corrected in the revision."
+ },
+ "createdAt": "2026-07-30T23:52:58.696Z",
+ "modifiedAt": "2026-11-19T16:49:18.827Z",
+ "url": "https://openreview.net/forum?id=nJdSfl9uaK&noteId=y9YDvu48Fu",
+ "license": "CC-BY-4.0"
+}