potentialpaper

Anatomy-aware Spatio-Temporal Modeling for Echocardiography Segmentation

Import NeurIPS 2026 submission 2TtThaZ1Ks: 7 notes

@openreview[bot] · 2026-11-22 17:53 UTC · d03ba34d6ea1

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,28 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "2TtThaZ1Ks"
+ }
+ ],
+ "title": "Anatomy-aware Spatio-Temporal Modeling for Echocardiography Segmentation",
+ "authors": [
+ "Seok-Hwan Oh",
+ "Guil Jung",
+ "Myeong-Gee Kim",
+ "Young-Min Kim",
+ "hyeonjik lee",
+ "Sang-yun Kim",
+ "Hyuksool Kwon",
+ "Hyeon-min Bae"
+ ],
+ "abstract": "Echocardiography segmentation plays a central role in quantitative cardiovascular assessment. However, automated echocardiography segmentation remains challenging due to speckle noise, poorly defined anatomical boundaries, acquisition variability, and the limited anatomical coverage of existing benchmarks. Conventional segmentation methods demonstrate limited accuracy under such low image quality and domain shifts. Inspired by the observation that expert cardiologists can maintain reliable anatomical delineation by leveraging their structural understanding of the cardiac anatomy, we propose that incorporating anatomical priors into echocardiography segmentation models can improve both precision and robustness. To this end, we propose AST-Seg, an anatomy-aware spatio-temporal framework for echocardiography segmentation. AST-Seg introduces an anatomy-aware feature encoder that regularizes transformer attention with anatomy-derived spatial-relation priors, and a Deformable Spatio-Temporal Mamba module that captures localized and periodic cardiac motion through adaptive spatial aggregation followed by temporal state-space modeling. In addition, we curate an Echocardiography Anatomy (EA) dataset with pixel-level annotations for 12 clinically relevant cardiac anatomy, enabling comprehensive multi-structure cardiac interpretation. Extensive experiments on in-distribution CAMUS and EA datasets, as well as an out-of-distribution point-of-care echocardiography dataset, demonstrate that AST-Seg provides domain-generalized segmentation with improved precision.",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/2ttthaz1ks/forms.json added

+++ b/reviews/openreview/2ttthaz1ks/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2ttthaz1ks/notes/8gneaghpiu.json added

+++ b/reviews/openreview/2ttthaz1ks/notes/8gneaghpiu.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "8GnEAgHpIu",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer SDjc",
+ "content": {
+ "summary": "The work proposes a US dataset with more detailed anatomical segmentation, and trains a unique anatomy aware encoder and spatio-temporal model to get accurate segmentations of the echo US image.",
+ "contribution_type": "use_inspired",
+ "strengths_and_weaknesses": "The work could use a little bit more detailed explanation on the anatomy representation learning. As of now, it is hard to understand how the positional embedding is created and trained. An overview of the whole training process and how it differs from the inference step could be of help.\n\nOtherwise, the work is sound and innovative. Ablation study is sufficiently provided.",
+ "quality": 4,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "Are the inference memory requirements significantly different? The hardware used for training seems to be something that cannot be provided in most clinical scenarios.\n\nIs there more reasoning behind how attention map in figure 4 is interpreted? With just the image, it is hard to see what one means by Dinov3 caring about similar local intensities, and why necessarily the segmentation map looking like attention map is better. Also, it would be helpful if there was a segmentation map as well, instead of just dots in the raw image, which I am assuming it is a centroid of each segment.\n\nIs there a reason why the DSTM is added as a refinement step of the segmentation rather than being aggregated during the initial segmentation mask creating process?",
+ "limitations": "I do not understand why foundational models are related work, other than serving as an alternative segmentation model. Anatomy aware models seems to be a better section to be added.",
+ "rating": 5,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "na",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The authors have addressed most of the comments except the limitations. I see no reason to change the reviews and scores based on the contribution type, as the points pointed out are generally applicable. I have looked at other reviewer's comments, and see that the concerns are similar and they have been addressed in a similar manner. However, since not all pints were addressed, and most of the scores are already high, I see no change and replies significant enough to change the scores."
+ },
+ "createdAt": "2026-06-21T19:35:14.633Z",
+ "modifiedAt": "2026-11-18T13:38:39.289Z",
+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks&noteId=8GnEAgHpIu",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2ttthaz1ks/notes/cmka54xtjp.json added

+++ b/reviews/openreview/2ttthaz1ks/notes/cmka54xtjp.json
@@ -0,0 +1,31 @@
+{
+ "schema": "review/1",
+ "id": "CmKA54xtjp",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer xSBs",
+ "content": {
+ "summary": "The authors propose AST-Seg, a cardiac structure segmentation model from ultrasound imaging that integrates spatio-temporal information extracted from echo videos (10 frames). The proposed architecture consists of three main components: an anatomy-aware Echo feature encoder (AEFE) that extracts frame-centric features, a spatio-temporal Mamba module with a Deformable Spatio-Temporal Mamba (DSTM) layer that captures temporal features in the Echo video, and a Temporal-Context Decoder that combine frame-centric and temporal features for segmentation.\n\nThe model was trained and evaluated on the public CAMUS dataset, as well as the in-house datasets: the newly curated Echo Anatomy dataset with 12 masks and point-of-care echography data. The results show that the proposed method achieves superior segmentation accuracy compared with state-of-the-art baselines, and the ablation study confirms that incorporating temporal information improves segmentation performance.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Overall, the authors present a strong architecture for leveraging temporal information in video echocardiography for frame-by-frame segmentation.\n\nHowever, the manuscript would benefit from a clearer overview of the full segmentation pipeline.\n\nIn particular, Section 3.2 currently lists the three main components without sufficiently explaining how they interact.\n\nWhile the anatomical attention is clear with the different structures, the temporal aspect of the MAMBA component is not sufficiently illustrated to understand its behaviour.\n\nIn addition, the authors should provide more detail regarding the training and testing setup, including the number of samples used for training and testing, as well as the standard deviation of the reported metrics.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "The authors report standard deviation in only one table, and only for the proposed method.\n\nWhile it is understandable that the authors want to demonstrate the added value of integrating temporal information for segmentation, it remains unclear how AST-Seg would perform in the single-frame setting, which is the case for all other baseline models in Tables 1 and 2. The results in Table 4b should therefore be the main comparison, since all baseline models also integrate temporal information for segmentation.\n\nComputational cost/time of the proposed model compared to single frame segmentation model (U-Net) should be reported and discussed.\n\nWhat is the baseline model used in the ablation study?\n\nWhat are the training and testing splits for each experiment?\n\nIn Appendix C.2, were the number of training inputs the same for CAMUS and CAMUS+EA ? The improvement in accuracy could be attributed to more training data in the case for CAMUS+EA.",
+ "limitations": "While the effort of curating the EA dataset is commendable, the manuscript does not clearly demonstrate a substantial novel contribution, especially if the authors do not intend to release the dataset.\n\nGiven the complexity of the proposed model, the overall pipeline from input to segmentation output should be described more clearly.\n\nThe discussion of limitations is rather short and does not sufficiently address the proposed model itself.",
+ "rating": 4,
+ "confidence": 5,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "NA",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes"
+ },
+ "createdAt": "2026-07-02T07:58:01.356Z",
+ "modifiedAt": "2026-11-18T13:38:36.262Z",
+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks&noteId=CmKA54xtjp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2ttthaz1ks/notes/damzo7ogae.json added

+++ b/reviews/openreview/2ttthaz1ks/notes/damzo7ogae.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "daMZo7OgaE",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer Qfaa",
+ "content": {
+ "summary": "AST-Seg is a framework for echocardiography video segmentation that integrates anatomy-aware representation learning with a deformable spatio-temporal state-space model. The anatomy-aware component regularizes transformer attention using spatial-relation priors derived from segmentation masks, supervising the encoder to capture token-level anatomical relationships across cardiac structures rather than relying on appearance similarity alone. The Deformable Spatio-Temporal Mamba (DSTM) module replaces global video-token serialization with deformable local spatial aggregation followed by per-location temporal state-space modeling, better aligned with the localized, periodic nature of cardiac motion. A Temporal-Context Decoder integrates current-frame and temporally refined features in a coarse-to-fine prediction scheme. Alongside the method, the paper introduces the EA dataset, which has 21,535 annotated frames from 3,110 subjects across 12 cardiac structures and three apical views, acquired from three vendors and five scanner models, substantially extending the anatomical coverage of existing benchmarks. Experiments are conducted on CAMUS and EA (in-distribution) and a curated point-of-care ultrasound dataset (out-of-distribution, evaluation only), with ablations isolating each component's contribution and comparisons against representation learning and temporal modeling alternatives.",
+ "contribution_type": "use_inspired",
+ "strengths_and_weaknesses": "This is a well-executed paper addressing a genuine clinical need with a technically coherent solution. The motivation is clinically grounded and translated into concrete architectural choices rather than serving only as narrative framing. The proposed DSTM module is particularly well motivated. Cardiac motion is localized and periodic rather than globally diffuse, making per-location deformable aggregation followed by temporal state-space modeling a more principled design than serializing all spatio-temporal patches into a single scan order. The efficiency advantage is also supported by the comparison in Table 4(b), where DSTM achieves stronger performance than the Video Transformer while requiring lower computational cost.\n\n\nA few areas could be strengthened. The anatomy affinity prior (Equation 7) models intra-structure token relationships but does not explicitly encode consistent spatial relationships between different anatomical structures, such as the mitral valve consistently lying between the left ventricle and left atrium. Such inter-structure constraints more closely resemble the anatomical reasoning used by clinicians and could provide an interesting direction for future work, rather than representing a limitation of the current study.\nThe ablation study would benefit from one additional variant in which the anatomy-aware cross-attention branches are retained while removing the attention supervision loss. This experiment would help distinguish whether the observed improvements arise primarily from the architectural modifications, the anatomical supervision signal, or the increased model capacity. The current comparison in Table 3 (baseline versus full AEFE) does not fully disentangle these factors. Demonstrating that the anatomical priors themselves, rather than the additional parameters, are responsible for the performance gains would further strengthen one of the paper's central claims.\nThe EA and PoC-Echo datasets represent valuable contributions. Including a concise description of the annotation protocol, inter-annotator agreement, and quality control procedures in the main paper, rather than referring entirely to the appendix, would improve transparency and increase confidence in the reported results. Clarifying whether the EA dataset will be publicly released would also strengthen the work's potential long-term impact.\nFinally, it would be helpful to clarify why the out-of-distribution evaluation on the PoC-Echo dataset reports results only for the LV blood pool, despite the broader anatomical scope of the proposed method. In addition, explicitly acknowledging that domain generalization is evaluated using a single external dataset would provide a more balanced discussion of the work's scope. This is a reasonable limitation of the current study and naturally motivates future validation across additional institutions and acquisition settings.",
+ "quality": 4,
+ "clarity": 4,
+ "significance": 3,
+ "originality": 3,
+ "questions": "The anatomy-aware representation learning is a central contribution of the paper. Could additional analysis clarify how much of the observed performance improvement is attributable to the anatomy supervision itself, rather than the increased model capacity introduced by the additional attention branches? An ablation retaining the anatomy-aware branches while removing the attention-supervision loss would help disentangle these effects.\nThe paper emphasizes improved domain generalization under distribution shift. Could the discussion elaborate on how well the proposed approach is expected to generalize beyond the single PoC-Echo dataset used for evaluation? While additional experiments may not be feasible during the rebuttal period, discussing this limitation would better contextualize the scope of the claims.\nThe EA dataset is an important contribution. Could additional details be provided regarding the annotation protocol, quality control procedures, inter-annotator agreement (if available), and plans for public release? This information would improve confidence in the dataset and further increase its value to the community.\nCould the paper clarify why the out-of-distribution evaluation reports results only for the LV blood pool, despite the broader anatomical scope of the proposed framework? Understanding whether this reflects annotation availability or another experimental constraint would help interpret the reported results.\nThe efficiency analysis in Table 4(b) reports FLOPs. If available, could the paper also include practical inference speed and GPU memory usage? These metrics would complement the FLOPs analysis and provide a more complete assessment of the computational trade-offs for real-world deployment.",
+ "limitations": "Partially. The manuscript could benefit from a more explicit discussion of its limitations. In particular, it would be valuable to acknowledge that domain generalization is demonstrated using a single external point-of-care dataset, which may not fully capture the diversity of real-world clinical settings. It would also be helpful to discuss that the anatomy-aware supervision relies on pixel-level annotations, potentially limiting applicability in scenarios where detailed anatomical labels are unavailable. Finally, the framework has been evaluated specifically for echocardiography, and its applicability to other ultrasound modalities remains an open question. Explicitly discussing these points would provide a more balanced presentation without diminishing the strength of the reported contributions.",
+ "rating": 4,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "N/A",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "#\n\n\n### What the rebuttal addressed\n\n**Anatomy supervision vs. model capacity (Q1)** is fully resolved and was the most important open question in my original review. Both experiments together provide convincing evidence for the paper's central claim about anatomical supervision.\n\n**Annotation protocol and dataset details (Q2/Q3)** are addressed. The four-stage annotation process is described in detail, annotator qualifications are specified, and the authors have committed to public code release and are preparing institutional approval for dataset release.\n\n**OOD evaluation scope (Q4)** is clearly explained. The authors have agreed to restate the generalization claim more precisely in the revised manuscript.\n\n**Inference efficiency (Q5)** is fully addressed. AST-Seg achieves 66 FPS on an RTX 4090 and 39 FPS on an RTX 3090 with 947 MB peak GPU memory, demonstrating real-time performance on clinically accessible hardware.\n\n### Overall,\n#### The rebuttal was responsive and substantive, directly addressing the experiments I requested and providing additional clinical validation. The remaining items, including dataset and code release, are commitments pending institutional processes rather than completed deliverables."
+ },
+ "createdAt": "2026-07-06T22:58:46.369Z",
+ "modifiedAt": "2026-11-18T13:38:32.770Z",
+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks&noteId=daMZo7OgaE",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2ttthaz1ks/notes/doc3jsiq36.json added

+++ b/reviews/openreview/2ttthaz1ks/notes/doc3jsiq36.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "dOC3JSIq36",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer hoYy",
+ "content": {
+ "summary": "This paper presents AST-Seg, an anatomy-aware spatio-temporal framework for echocardiography segmentation. The method combines an anatomy-aware feature encoder with mask-derived token-relation supervision, a deformable spatio-temporal Mamba module for temporal context modeling, and a temporal-context decoder for coarse-to-fine mask prediction. The authors also curate a multi-structure echocardiography anatomy dataset with pixel-level annotations for 12 cardiac structures and evaluate robustness using a portable-device PoC-Echo dataset. Experiments on CAMUS, EA, and PoC-Echo show that AST-Seg outperforms conventional, SAM-based, and video segmentation baselines, suggesting the benefit of incorporating anatomical priors and temporal modeling for robust Echo segmentation.",
+ "contribution_type": "use_inspired",
+ "strengths_and_weaknesses": "## 1) Strengths\n\n- **[Clinically meaningful use case]** The paper addresses echocardiography segmentation, a clinically relevant problem with clear real-world importance. This fits the User-Inspired contribution type, where the use case should be meaningful and not artificially constructed.\n\n- **[Echo-specific method design]** AST-Seg is reasonably tailored to Echo-specific challenges such as speckle noise, ambiguous boundaries, device variation, and cardiac motion. Its anatomy-aware encoder, temporal Mamba module, and temporal-context decoder are all motivated by properties of the target use case.\n\n- **[Valuable dataset contribution]** The curated EA dataset provides pixel-level annotations for 12 cardiac structures, which is broader than many Echo segmentation datasets. The additional PoC-Echo dataset also supports evaluation under a realistic portable-ultrasound domain shift.\n\n---\n\n## 2) Major Weakness\n\n- **[Unclear temporal training protocol]** \n AST-Seg uses 10-frame clips, but the EA dataset is described as having only one representative annotated frame per video. It is unclear how clips are sampled, which frame is supervised, and how unlabeled neighboring frames are used during training and evaluation.\n\n- **[Ambiguous anatomy-conditioned segmentation formulation]** \n The model takes an anatomical condition \\(c\\) as input, but it is unclear whether the output is a condition-specific binary mask or a full multi-class segmentation mask. This also makes Eq. (17) ambiguous, since \\(Y\\) could denote either the full annotation or the queried anatomy mask \\(Y_c\\).\n\n- **[Incomplete attention supervision formulation]** \n The mask-derived attention targets are binary affinity matrices, but cross-entropy requires valid probability distributions. The paper does not specify how these targets are normalized or how all-zero rows from background or non-target tokens are handled.\n\n- **[Limited corruption robustness analysis]** \n The robustness claim is mainly supported by the PoC-Echo dataset. However, the paper does not systematically evaluate Echo-specific corruptions such as speckle noise, blur, gain/contrast shifts, low resolution, acoustic shadowing, or compression artifacts.\n\n- **[Incomplete clinical use-case evaluation]** \n For a User-Inspired contribution, the evaluation should be aligned with the real-world use case. The paper reports Dice, mIoU, and HD95, but does not evaluate clinically relevant quantities such as LV volume, ejection fraction, wall thickness, chamber area, inter-observer variability, or clinically acceptable error ranges.\n\n---\n\n## 3) Minor Weakness\n\n- **[Some claims are slightly overstated]** \n The paper describes the mask-derived prior as capturing “global cardiac organization,” but Eq. (8) mainly models intra-structure token affinity rather than inter-structure anatomical topology. Similarly, DSTM is motivated by periodic cardiac motion, but the formulation does not explicitly model periodicity through phase encoding, cycle consistency, or ECG-gated information.\n\n- **[Incomplete FLOPs reporting for temporal models]** \n Table 3 reports FLOPs per frame, but the video models use 10-frame clips. Reporting only per-frame FLOPs may understate the actual temporal inference cost. Clip-level FLOPs, latency, memory usage, or total inference cost would provide a clearer efficiency comparison.\n\n- **[Incomplete statistical reporting]** \n In Table 1, uncertainty values appear only for the proposed method, while baselines do not report variance or confidence intervals. It is also unclear whether the reported values correspond to seed-wise, fold-wise, or case-level variation. Providing the same statistical reporting for all methods would make the comparison more reliable.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 4,
+ "originality": 3,
+ "questions": "## Questions\n\n1. **Temporal clip protocol** \n AST-Seg uses 10-frame clips, but EA has one annotated frame per video. Which frame is supervised, and how are neighboring unlabeled frames used? My score would increase if the authors clearly specify the clip sampling and supervision protocol.\n\n2. **Anatomy-conditioned output** \n Does the model predict a condition-specific binary mask or a full multi-class mask? If it is binary, how are 12 anatomy predictions merged at inference? My score would increase if Eq. (17) and the inference procedure are clarified.\n\n3. **Attention target construction** \n How are the binary affinity matrices normalized before cross-entropy? How are all-zero rows from background or non-target tokens handled? My score would increase if the authors provide the exact definition of the target attention map.\n\n4. **Robustness and clinical relevance** \n Can the authors provide lightweight device-wise PoC results, corruption analysis, or clinical measurement errors such as LV area/volume or EF error? This would clarify whether the gains are meaningful for the intended clinical use case.\n\n5. **Comparison fairness and cost** \n Did all baselines use the same training data, pretraining resources, input resolution, and temporal inputs where applicable? Since AST-Seg uses 10-frame clips, clip-level FLOPs, latency, or memory would make the efficiency comparison clearer.",
+ "limitations": "No.\n\nThe paper does not adequately discuss several important limitations. The authors should explicitly acknowledge that the temporal training protocol is under-specified given the single annotated frame per video, that PoC-Echo evaluates only LV BP and therefore does not establish OOD robustness for all 12 anatomies, and that the evaluation is limited to segmentation metrics rather than clinically meaningful measurements such as LV volume or EF error. They should also discuss practical deployment constraints, including 10-frame clip availability, latency, memory, and device-wise reliability.",
+ "rating": 5,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "N/A",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "Thank you for the detailed rebuttal. The authors have adequately clarified the temporal training protocol, the condition-specific binary segmentation formulation, and the construction of the attention supervision target. The newly added EF evaluation also meaningfully strengthens the clinical relevance of the work.\n\nSome limitations remain, particularly the lack of systematic artifact- or device-wise robustness analysis and the absence of clip-level and full 12-condition inference costs. These issues should be clearly acknowledged and reported in the revised manuscript. Overall, however, the rebuttal resolves the main concerns underlying my initial rating, and I therefore increase my score by one point."
+ },
+ "createdAt": "2026-07-05T11:30:19.617Z",
+ "modifiedAt": "2026-11-18T13:38:34.794Z",
+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks&noteId=dOC3JSIq36",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2ttthaz1ks/notes/lnkefvchfg.json added

+++ b/reviews/openreview/2ttthaz1ks/notes/lnkefvchfg.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "LnKEFvChfG",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair tdXk",
+ "content": {
+ "metareview": "- Reviewers generally view this as a strong use inspired paper with a clinically meaningful Echo segmentation target.\n- The EA dataset and broad anatomical coverage are a major part of the contribution.\n- The main requested clarification is the temporal protocol: 10-frame clips versus one annotated frame per video.\n- Reviewers also ask for stronger evidence that anatomy supervision, not just model capacity/pretraining scale, drives the gains.\n- Empirical results support improved segmentation, but OOD and clinical utility claims are narrower than stated.\n- Dataset/code release and annotation quality details are important for impact and reproducibility."
+ },
+ "createdAt": "2026-07-21T15:06:04.577Z",
+ "modifiedAt": "2026-11-18T15:20:45.873Z",
+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks&noteId=LnKEFvChfG",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2ttthaz1ks/notes/rk4x2jifuq.json added

+++ b/reviews/openreview/2ttthaz1ks/notes/rk4x2jifuq.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "rK4x2JIfUq",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "- Reviewers generally view this as a strong use inspired paper with a clinically meaningful Echo segmentation target.\n- The EA dataset and broad anatomical coverage are a major part of the contribution.\n- The main requested clarification is the temporal protocol: 10-frame clips versus one annotated frame per video.\n- Reviewers also ask for stronger evidence that anatomy supervision, not just model capacity/pretraining scale, drives the gains.\n- Empirical results support improved segmentation, but OOD and clinical utility claims are narrower than stated.\n- Dataset/code release and annotation quality details are important for impact and reproducibility.",
+ "final_justification": "Overall, there is an agreement among all reviewers that the paper should be accepted."
+ },
+ "createdAt": "2026-09-24T11:19:49.552Z",
+ "modifiedAt": "2026-11-18T14:54:29.496Z",
+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks&noteId=rK4x2JIfUq",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2ttthaz1ks/notes/v6ryle7dj7.json added

+++ b/reviews/openreview/2ttthaz1ks/notes/v6ryle7dj7.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "V6RyLE7Dj7",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer qsR1",
+ "content": {
+ "summary": "The paper proposes AST-Seg, an anatomy-aware spatio-temporal framework designed for echocardiography (Echo) video segmentation. The architecture is composed of three primary modules: an Anatomy-aware Echo Feature Encoder (AEFE) that incorporates spatial-relation priors into Vision Transformer (ViT) attention mechanisms, a Deformable Spatio-Temporal Mamba (DSTM) module intended to capture localized and periodic cardiac motion, and a Temporal-Context Decoder (TCD) for mask generation. To validate the framework, the authors also curate the Echo Anatomy (EA) dataset, providing pixel-level annotations for 12 cardiac structures across 21,535 frames.",
+ "contribution_type": "use_inspired",
+ "strengths_and_weaknesses": "Strengths:\n1. Valuable Clinical Dataset: The curation of the EA dataset is the most substantial contribution of this work. By expanding the anatomical scope to 12 structures across 21,535 frames, substantially surpassing existing benchmarks like CAMUS or EchoNet-Dynamic that focus primarily on the left ventricle, this dataset provides a critical resource for comprehensive cardiac assessment. \n2. Rigorous Empirical Evaluation: The experimental design is thorough. The authors evaluate the framework on both In-Distribution (CAMUS, EA) and Out-of-Distribution (PoC-Echo) datasets, robustly demonstrating the model's generalization capabilities under severe domain shifts (e.g., low-end portable ultrasound devices). \n\nWeaknesses:\n1. Incremental Methodological Innovation: While the proposed AST-Seg achieves strong empirical results, its architectural novelty is somewhat limited from a purely algorithmic perspective. The AEFE primarily relies on standard cross-attention mechanisms regularized by pre-computed binary mask affinities (Equation 7). Similarly, the DSTM module is essentially a sequential application of Deformable Attention and standard Mamba blocks. The straightforward integration of these existing paradigms, though highly effective for this specific clinical task, lacks fundamental theoretical or structural innovation for the broader representation learning community. \n2. Restricted Access to the Core Contribution: The primary scientific value of this paper lies in the newly curated EA dataset. However, the checklist explicitly states that the code and data are not provided at submission and will only be shared \"upon request\". For a \"Use-inspired\" paper with limited methodological novelty, the unavailability of the dataset severely undermines its reproducibility and potential impact, making it difficult for the community to benchmark against it. \n3. Suboptimal Formulation of the Anatomical Prior: The affinity matrix defined in Equation (7) uses a hard, binary indicator function based on downsampled masks. Given the authors' own premise that echocardiography suffers from highly ambiguous boundaries and speckle noise, enforcing a rigid 0/1 token-to-token affinity is contradictory to the continuous and uncertain nature of ultrasound imaging. A hard inductive bias here risks over-constraining the attention maps and ignoring boundary uncertainties.",
+ "quality": 3,
+ "clarity": 4,
+ "significance": 3,
+ "originality": 2,
+ "questions": "1. Dataset Release: Given the incremental nature of the methodological design, the unreleased EA dataset constitutes the true core contribution of this work. A conditional release (\"upon request\") is insufficient for a top-tier venue to validate its impact. If the authors can make a concrete, verifiable commitment to fully open-source the EA dataset upon acceptance, I am willing to raise my score to an Accept during the rebuttal phase. Will you publicly release this dataset?\n\n2. Justification of the Rigid Anatomical Prior (Eq. 7): How do you justify the use of a hard, binary indicator function for anatomical affinity in images known for ambiguous boundaries? Have you experimented with soft, probabilistic, or distance-based affinity matrices that might better model the continuous uncertainty at tissue interfaces?\n\n3. Robustness to Heart Rate Variability (Phase-Awareness): How does the DSTM module behave when the fixed T=10 window captures different phase proportions of a cardiac cycle across patients with varying heart rates? Did you apply any temporal interpolation or ECG-based phase alignment prior to feeding the sequence into the DSTM? A discussion or ablation on varying sequence lengths relative to heart rates would strengthen the claim of modeling \"periodic\" motion.\n\n4. Disentangling Pretraining Bias from Architectural Gains: The AEFE is pretrained on a massive, proprietary 7.9M-frame Echo dataset using Masked Image Modeling (MIM). It is unclear whether the robust representation is derived from the proposed anatomy-aware attention regularizations L_attn or simply from the sheer scale of the pretraining data. Could you provide an ablation study training AST-Seg *without* the 7.9M MIM pretraining to clarify the true methodological efficacy of the architectural design?",
+ "limitations": "No. The authors correctly acknowledge that their dataset is limited to apical views. However, they overlook the algorithmic limitations inherent to their proposed method. Specifically, the authors should critically discuss the limitations of using a hard binary representation for anatomical priors in medical images with high structural ambiguity. Furthermore, they should address the physiological limitations of using a fixed temporal frame window (T=10) when evaluating cardiac videos with naturally varying heart rates and cardiac cycle lengths.",
+ "rating": 4,
+ "confidence": 5,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "None. The structural formatting and the usage of LaTeX for formal math strictly adhere to standard academic typesetting guidelines.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The authors have addressed my primary technical and experimental concerns in the rebuttal. While the core algorithmic components remain somewhat incremental from a general representation learning standpoint, the paper's strength as a \"Use-inspired\" contribution is substantially reinforced by the new ablation studies and protocol clarifications."
+ },
+ "createdAt": "2026-06-23T02:46:07.205Z",
+ "modifiedAt": "2026-11-18T13:38:37.778Z",
+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks&noteId=V6RyLE7Dj7",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2ttthaz1ks/submission.json added

+++ b/reviews/openreview/2ttthaz1ks/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "2TtThaZ1Ks",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 12299,
+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks",
+ "license": "CC-BY-4.0"
+}

versions/v_sn6s38mx.json added

+++ b/versions/v_sn6s38mx.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-05-01",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 12299,
+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks",
+ "reviews": "openreview/2ttthaz1ks",
+ "evidence": [
+ "https://openreview.net/forum?id=2TtThaZ1Ks"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks",
+ "evidence": [
+ "https://openreview.net/forum?id=2TtThaZ1Ks"
+ ]
+}