Anatomy-aware Spatio-Temporal Modeling for Echocardiography Segmentation
Update NeurIPS 2026 submission 2TtThaZ1Ks: 12 notes
@openreview[bot] · 2026-11-24 15:45 UTC · feaff9b42a80 ·
reviews/openreview/2ttthaz1ks/notes/4wo77iio7e.json added
+++ b/reviews/openreview/2ttthaz1ks/notes/4wo77iio7e.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "4wO77Iio7E",+ "replyTo": "CmKA54xtjp",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We are grateful to Reviewer xSBs for the detailed review of our manuscript and for the thoughtful questions. We have carefully addressed the comments below.\n\n**Q1. Baseline model used in the ablation study.**\n\n**A1.** The baseline in Table 3 is a single-frame ViT-based segmentation network obtained by removing AEFE, DSTM, and the temporal-refinement stage from AST-Seg. The baseline network employs ViT-Base encoder for feature extraction, without the anatomy-aware branches. Since the baseline network employs only single frame echocardiography (Echo) image, the decoder predicts the segmentation mask without employing information from adjacent Echo frames.\n\n\n\n**Q2. Comparative analysis in single temporal frame**\n\n**A2.**\n\n\nWe agree that the evaluation should distinguish the contribution of anatomy-aware image representation from that of temporal modeling. We therefore evaluated a single-frame variant, denoted AST-Seg-SF, which retains the AEFE while removing DSTM and the temporal-refinement stage of the TCD (Table 3 of the main manuscript). AST-Seg-SF takes a single B-mode frame as input and directly predicts the corresponding segmentation mask without using information from adjacent frames. As shown in the table, AST-Seg-SF demonstrates the competitive overall performance among the single-frame methods. The results indicate that the proposed anatomy-aware representation learning is effective independently of temporal modeling.\n\n**Table R1. Comparative assessment of AST-Seg-SF and single-frame image segmentation baselines**\n\n| Method (single-frame input) | LV BP | | | LV wall | | | LA BP | | |\n|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|\n| | **Dice** | **mIoU** | **HD95** | **Dice** | **mIoU** | **HD95** | **Dice** | **mIoU** | **HD95** |\n| U-Net | 92.22 | 85.75 | 7.53 | 83.87 | 72.59 | 9.09 | 85.99 | 76.59 | 10.78 |\n| H2Former | 92.91 | 86.98 | 6.61 | 86.15 | 75.93 | 6.82 | 88.02 | 79.41 | 8.95 |\n| MedSAM | 88.87 | 82.66 | 8.45 | 81.30 | 71.59 | 8.32 | 88.28 | 80.59 | 10.38 |\n| SAMed | 91.79 | 84.98 | 7.76 | 84.77 | 73.91 | 8.13 | 88.06 | 79.61 | 10.23 |\n| SAMUS | 91.22 | 85.12 | 6.72 | 84.39 | 75.02 | 6.85 | 88.64 | 80.35 | 8.22 |\n| **AST-Seg-SF** | 93.32 | 87.56 | 5.04 | 86.77 | 76.82 | 6.21 | 88.64 | 80.09 | 7.84 |\n\n\nIn addition, the full AST-Seg model further improves segmentation performance by incorporating temporally refined anatomical features through DSTM and TCD, outperforming video segmentation methods, MediViSTA and MemSAM.\n\n\n**Table R2. Comparative assessment of AST-Seg and video segmentation baselines**\n\n\n| Method (video input) | LV BP | | | LV wall | | | LA BP | | |\n|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|\n| | **Dice** | **mIoU** | **HD95** | **Dice** | **mIoU** | **HD95** | **Dice** | **mIoU** | **HD95** |\n| MediViSTA | 90.94 | 83.65 | 7.73 | 83.19 | 71.66 | 7.71 | 87.10 | 78.16 | 9.39 |\n| MemSAM | 93.24 | 87.53 | 4.79 | 87.74 | 78.41 | 7.19 | 88.08 | 79.22 | 9.50 |\n| **AST-Seg** | 95.03 | 90.57 | 4.75 | 89.00 | 80.29 | 5.89 | 89.52 | 81.53 | 6.86 |\n\n**Q3. Computation cost comparison**\n\n**A3.**\n\nWe thank the reviewer for this valuable suggestion. The table reports the parameter count and per-frame inference latency, measured on a single NVIDIA RTX 4090 GPU.\n\n**Table R3. Computational cost assessments**\n\n| Method | Params (M) | Latency / frame (ms) |\n|:--|:--|:--|\n| U-Net | 31.03 | 5.38 |\n| SwinUNet | 27.16 | 13.0 |\n| H2Former | 33.69 | 8.54 |\n| MedSAM | 90.74 | 11.5 |\n| MSA | 104.3 | 15.0 |\n| SAMed | 90.60 | 12.8 |\n| SAMUS | 133.3 | 20.5 |\n| MemSAM | 152.0 | 19.4 |\n| MediViSTA | 171.9 | 16.7 |\n| **AST-Seg** | **115.5** | **15.1** |\n\nAmong the video-based methods, AST-Seg has the fewest parameters and achieves the lowest per-frame latency. The computation cost of AST-Seg is also comparable to that of single-frame SAM-based methods such as MSA and SAMed while achieving higher segmentation accuracy.\n\nConventional architectures including U-Net, SwinUNet, and H2Former, are more computationally efficient. However, the network presents consistently lower performance in both in-distribution, and out-of-distribution evaluation. For example, compared with U-Net, AST-Seg requires additional computational cost, but substantially improves performance on the out-of-distribution PoC-Echo benchmark from 80.90 to 90.83 Dice score.\n\nWe will include the computational cost analysis of AST-Seg and discuss the limitations in the revised manuscript."+ },+ "createdAt": "2026-07-30T07:24:51.572Z",+ "modifiedAt": "2026-11-19T17:19:20.363Z",+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=4wO77Iio7E",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ttthaz1ks/notes/6zncg9jct7.json added
+++ b/reviews/openreview/2ttthaz1ks/notes/6zncg9jct7.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "6ZNCG9jCt7",+ "replyTo": "CmKA54xtjp",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "**Q6. Statistical analysis.**\n\n**A6.** We appreciate the reviewer’s valuable comment. We agree that reporting the statistical variability assessments enables more rigorous analysis of the study. Accordingly, we have supplemented the results with the corresponding standard deviations.\n\n**Table R5. Statistical analysis of AST-Seg and comparative baselines (mean ± std).**\n\n| | CAMUS | | | | | | | | | PoC-Echo | | |\n|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|\n| **Method** | **LV BP** | | | **LV wall** | | | **LA BP** | | | **LV BP** | | |\n| | **mDice** | **mIoU** | **HD95** | **mDice** | **mIoU** | **HD95** | **mDice** | **mIoU** | **HD95** | **mDice** | **mIoU** | **HD95** |\n| U-Net | 92.22 | 85.75 | 7.53 | 83.87 | 72.59 | 9.09 | 85.99 | 76.59 | 10.78 | 80.90 | 71.28 | 25.66 |\n| | ±3.56 | ±5.80 | ±6.55 | ±5.47 | ±7.92 | ±5.61 | ±9.63 | ±13.98 | ±9.56 | ±19.08 | ±21.52 | ±20.52 |\n| SwinUNet | 92.61 | 86.40 | 6.74 | 86.45 | 76.38 | 7.29 | 88.51 | 80.23 | 9.10 | 82.91 | 73.24 | 27.31 |\n| | ±3.33 | ±5.37 | ±5.57 | ±4.41 | ±6.39 | ±4.01 | ±8.15 | ±11.61 | ±9.35 | ±17.06 | ±17.04 | ±19.73 |\n| H2Former | 92.91 | 86.98 | 6.61 | 86.15 | 75.93 | 6.82 | 88.02 | 79.41 | 8.95 | 83.10 | 72.92 | 21.37 |\n| | ±3.72 | ±6.40 | ±4.18 | ±4.47 | ±6.71 | ±3.53 | ±7.82 | ±11.63 | ±8.45 | ±14.36 | ±15.09 | ±17.32 |\n| MedSAM | 88.87 | 82.66 | 8.45 | 81.30 | 71.59 | 8.32 | 88.28 | 80.59 | 10.38 | 85.46 | 78.01 | 16.62 |\n| | ±16.20 | ±18.56 | ±11.84 | ±19.75 | ±18.96 | ±9.33 | ±12.84 | ±14.12 | ±10.75 | ±17.61 | ±22.31 | ±15.66 |\n| MSA | 91.12 | 84.54 | 8.17 | 84.55 | 73.62 | 7.39 | 87.91 | 79.19 | 8.73 | 86.19 | 77.57 | 21.27 |\n| | ±8.12 | ±11.55 | ±6.01 | ±5.38 | ±8.36 | ±6.71 | ±7.96 | ±10.82 | ±6.10 | ±11.83 | ±17.96 | ±19.14 |\n| SAMed | 91.79 | 84.98 | 7.76 | 84.77 | 73.91 | 8.13 | 88.06 | 79.61 | 10.23 | 86.37 | 79.22 | 19.83 |\n| | ±3.63 | ±4.81 | ±5.07 | ±6.23 | ±6.57 | ±7.16 | ±8.99 | ±11.87 | ±9.16 | ±17.15 | ±21.40 | ±20.81 |\n| SAMUS | 91.22 | 85.12 | 6.72 | 84.39 | 75.02 | 6.85 | 88.64 | 80.35 | 8.22 | 86.14 | 79.02 | 13.50 |\n| | ±10.93 | ±12.92 | ±4.34 | ±14.93 | ±15.83 | ±4.45 | ±7.01 | ±11.99 | ±7.35 | ±19.04 | ±20.39 | ±12.88 |\n| MemSAM | 93.24 | 87.53 | 4.79 | 87.74 | 78.41 | 7.19 | 88.08 | 79.22 | 9.50 | 87.48 | 80.05 | 12.83 |\n| | ±4.08 | ±5.24 | ±4.24 | ±4.29 | ±6.63 | ±6.25 | ±6.31 | ±9.31 | ±6.92 | ±14.05 | ±18.96 | ±11.62 |\n| MediViSTA | 90.94 | 83.65 | 7.73 | 83.19 | 71.66 | 7.71 | 87.10 | 78.16 | 9.39 | 83.65 | 73.82 | 23.91 |\n| | ±4.15 | ±6.99 | ±4.43 | ±6.16 | ±8.43 | ±5.77 | ±9.33 | ±12.31 | ±7.15 | ±12.67 | ±17.86 | ±20.94 |\n| **AST-Seg (Ours)** | **95.03** | **90.57** | **4.75** | **89.00** | **80.29** | **5.89** | **89.52** | **81.53** | **6.86** | **90.83** | **83.59** | **11.21** |\n| | **±1.70** | **±2.74** | **±4.15** | **±2.80** | **±4.41** | **±3.12** | **±5.77** | **±8.42** | **±4.50** | **±5.45** | **±8.47** | **±8.56** |\n\nThe table reports the performance of AST-Seg and the comparative baseline. The proposed AST-Seg presents low standard deviation compared to baseline networks, indicating that the segmentation performance remains stable across cases. We will include the statistics in the revised manuscript.\n\n**Q7. Clearer overview of the full segmentation pipeline**\n\n**A7.**\n\nWe thank the reviewer for this helpful suggestion. The segmentation is performed by following procedures. Given a 10-frame Echo clip $\\lbrace I^{t}\\rbrace\\_{t=1}^{10}$ and an anatomical condition $c$, each frame is independently processed by the shared AEFE to extract anatomy-aware features:\n\n$\\displaystyle \\bar{x}^{t} = AEFE(I^{t}, c), \\qquad t = 1, \\ldots, 10.$\n\nDSTM then jointly processes the complete feature sequence to incorporate temporal context:\n\n$\\displaystyle \\lbrace x^{t}\\rbrace\\_{t=1}^{10} = DSTM(\\lbrace \\bar{x}^{t}\\rbrace\\_{t=1}^{10}).$\n\nFor the target frame, TCD first generates a coarse condition-specific binary mask from the frame-faithful feature $\\bar{x}^{t}$ and subsequently refines it using the DSTM-derived temporal-context feature $x^{t}$. Following the reviewer's suggestion, we will add clearer overview at the beginning of Section 3.2 in the revised manuscript.\n\n**Q8. Clearer description of DSTM.**\n\n**A8**\n\nThe DSTM models temporal dynamics in two stages. DSTM first aggregates local spatial features within each frame via deformable sampling, enabling the model to track structures whose shape and position vary across the cardiac cycle. The resulting feature trajectory at each spatial location is then processed by a Mamba-based state-space model, which incorporates information from neighboring frames into the representation of the target frame.\n\nUnlike conventional Video Transformer or Video Mamba schemes, which flatten all spatio-temporal tokens into a single sequence, the DSTM preserves spatial correspondence while modeling temporal evolution across the cardiac cycle. We will revise the figure and clarify the description accordingly."+ },+ "createdAt": "2026-07-30T07:21:15.614Z",+ "modifiedAt": "2026-11-19T17:19:20.368Z",+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=6ZNCG9jCt7",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ttthaz1ks/notes/awgis9cf0h.json added
+++ b/reviews/openreview/2ttthaz1ks/notes/awgis9cf0h.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "awgis9cf0h",+ "replyTo": "daMZo7OgaE",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "**Q4. Why only LV BP on PoC-Echo?**\n\n**A4.**\n\nWe appreciate the reviewer’s request for clarification. The PoC-Echo dataset was acquired with portable ultrasound devices and therefore exhibits lower image quality, stronger artifacts, and less distinct anatomical boundaries than the conventional echocardiography datasets. To ensure reliable ground-truth delineation and limit label noise under these conditions, we restricted annotation to the LV blood pool, whose boundary is comparatively well defined at this image quality, and which is also one of the most clinically established segmentation targets in echocardiographic assessment. Therefore, the single-structure evaluation reflects the annotation scope of the PoC-Echo dataset rather than a limitation of the proposed framework.\n\n\n**Q5. Inference speed and memory. Feasibility under clinically accessible resource**\n\n\n**A5.**\n\nTo assess deployment feasibility on hardware representative of clinical environments, we measured the inference latency, throughput, and peak GPU memory usage of AST-Seg on NVIDIA RTX 4090 and RTX 3090 GPUs. As summarized in the table, AST-Seg achieved real-time inference on both devices, processing 66 FPS on the RTX 4090 and 39 FPS on the RTX 3090, while requiring only 947 MB of peak GPU memory. The results demonstrate that AST-Seg can operate efficiently on computational resources realistically available in practical clinical environments.\n\n\n**Table R2. Computational cost experiments**\n| Method | NVIDIA RTX 4090 | | NVIDIA RTX 3090 | | Peak GPU memory |\n|:--|:--|:--|:--|:--|:--|\n| | **Latency / frame** | **Frame / second** | **Latency / frame** | **Frame / second** | |\n| **AST-Seg** | 15.1 ms | 66 FPS | 25.8 ms | 39 FPS | 947 MB |\n\n\n**Q6. Intra and inter-structure token relations**\n\n**A6.**\n\nWe thank the reviewer for this insightful suggestion. As the reviewer observes, the affinity prior explicitly supervises intra-structure token relations, whereas inter-structure interactions are modeled implicitly through feature aggregation in the global anatomy branch. We agree that explicitly modeling inter-structure constraints could more faithfully reflect clinical anatomical reasoning, and we will describe this as a promising direction for future work in the revised manuscript."+ },+ "createdAt": "2026-07-30T06:47:47.510Z",+ "modifiedAt": "2026-11-19T17:19:20.645Z",+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=awgis9cf0h",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ttthaz1ks/notes/bnpwm3ha5n.json added
+++ b/reviews/openreview/2ttthaz1ks/notes/bnpwm3ha5n.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "bnpWm3ha5n",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "General response",+ "comment": "We sincerely thank all reviewers and the Area Chair for recognizing the contributions of our work and for providing constructive feedback that has helped us strengthen the paper. In response, we have made the following key clarifications and additional analyses.\n\n- We performed extended ablation studies to disentangle the effects of anatomical supervision, model capacity, and pretraining. The experiments demonstrate that the observed gains are primarily driven by the proposed anatomical supervision rather than by increased model capacity or pretraining scale.\n\n- We clarified the temporal composition of the data and the corresponding training and evaluation protocols, including how the echocardiography sequence is constructed from a complete cardiac cycle and which frame receives segmentation supervision.\n\n- To assess the clinical relevance of AST-Seg, we evaluated ejection fraction (EF) estimation. AST-Seg achieved the highest Pearson correlation coefficient (r=0.8711) with the reference EF and the lowest estimation error (MAE=3.36%) among the evaluated methods.\n\n- To assess practical deployment feasibility, we measured the computational cost of AST-Seg on hardware representative of clinical environments. The results demonstrate that the model operates efficiently on computational resources realistically available in clinical practice.\n\n- We specified the domain differences between the proposed PoC-Echo dataset and conventional echocardiography acquisitions, and clarified our generalization claim accordingly.\n\n- Statistical reporting has been expanded to include standard deviations for AST-Seg and all comparative baselines. \n\n- To improve reproducibility, we commit to publicly releasing the code. We have detailed the annotation protocol of the proposed datasets and are preparing the institutional approval required for open release of the dataset.\n\nWe will incorporate the additional experimental results, expanded discussions, and methodological clarifications presented during the rebuttal process into the revised manuscript."+ },+ "createdAt": "2026-08-04T09:03:11.913Z",+ "modifiedAt": "2026-11-19T17:19:20.048Z",+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=bnpWm3ha5n",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ttthaz1ks/notes/eoieddxezb.json added
+++ b/reviews/openreview/2ttthaz1ks/notes/eoieddxezb.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "EOiEdDxezB",+ "replyTo": "dOC3JSIq36",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "**Q4. Can the authors provide clinical measurement errors such as LV area/volume or EF error?**\n\n**A4.**\n\nWe thank the reviewer for this valuable suggestion, and we agree that clinically relevant measurements are essential for assessing clinical applicability. We therefore evaluated ejection-fraction (EF) estimation for AST-Seg and comparative baselines on the CAMUS benchmark. EF was computed from end-diastolic and end-systolic volumes obtained with Simpson's biplane method, and we report the Pearson correlation coefficient with the reference EF together with the mean absolute error (MAE).\n\n| Method | Pearson coefficient | MAE [%] |\n|:--|:--|:--|\n| U-Net | 0.7945 | 6.31 |\n| H2former | 0.8010 | 5.50 |\n| MedSAM | 0.6145 | 7.23 |\n| MSA | 0.8058 | 5.45 |\n| SAMed | 0.8115 | 4.53 |\n| MemSAM | 0.8279 | 4.26 |\n| MediViSTA | 0.7261 | 7.37 |\n| **AST-Seg** | **0.8711** | **3.36** |\n\nAs shown in the table, AST-Seg achieves the highest correlation and the lowest EF estimation error among all evaluated methods. The results indicate that its improvements in segmentation accuracy translate into more accurate estimation of a clinically important functional measurement. We will include these results and the corresponding discussion in the revised manuscript.\n\n**Q5. Limited corruption robustness analysis**\n\n**A5.**\n\nTo evaluate out-of-distribution robustness, we have curated the PoC-Echo dataset using representative portable ultrasound devices. Compared with high-end console-based echocardiography systems commonly used in clinical practice, portable devices typically produce images with lower spatial resolution, reduced signal-to-noise ratio, and more pronounced imaging artifacts. We therefore employed PoC-Echo as an external benchmark representing a clinically relevant portable-device domain shift.\n\nWe agree that evaluation on PoC-Echo alone does not establish universal domain generalization. A more comprehensive assessment would require validation across additional institutions, operator experience levels, and artifact conditions. We will accordingly revise the manuscript to state our claim more precisely and explicitly identify broader multi-institutional and multi-domain validation as an important direction for future work.\n\n**Q6. Are all baselines evaluated in fair assessment environment?**\n\n**A6.**\n\nWe thank the reviewer for this important question. All methods were evaluated under a consistent evaluation protocol, using identical training and test splits, 256×256 input resolution, and evaluation metrics. For video-based methods, including MemSAM, MediViSTA, and AST-Seg, the same chronologically ordered 10-frame clips were provided. We will clarify the details in the revised manuscript."+ },+ "createdAt": "2026-07-30T07:10:33.633Z",+ "modifiedAt": "2026-11-19T17:19:20.382Z",+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=EOiEdDxezB",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ttthaz1ks/notes/hrc74wu4xf.json added
+++ b/reviews/openreview/2ttthaz1ks/notes/hrc74wu4xf.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "HrC74Wu4XF",+ "replyTo": "dOC3JSIq36",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank Reviewer hoYy for the detailed and constructive feedback. We address each point below and will incorporate methodological clarifications and the evaluations into the revised manuscript.\n\n**Q1. Unclear temporal training protocol**\n\n**A1.**\n\nWe appreciate the opportunity to clarify the temporal training protocol.\n\nEach EA sample is constructed from an echocardiography video spanning one cardiac cycle. We uniformly subsample 10 chronologically ordered frames across the cardiac cycle, denoted by $\\lbrace I^{1},\\ldots,I^{10}\\rbrace$. During dataset construction, one frame of the clip, $I^{t}$, is annotated with a set of ground-truth masks $Y^{t}$. Here, $Y^{t} = \\lbrace Y\\_{c}^{t}\\rbrace\\_{c \\in \\mathcal{C}}$ comprises a segmentation mask for each anatomy condition $c$ annotated in the corresponding view, where $\\mathcal{C} \\subseteq \\lbrace 1,\\ldots,K\\rbrace$ ($K = 12$). The temporal position $t$ is randomly selected across samples, so the model is not biased toward a fixed annotated index.\n\nAST-Seg is optimized through the following procedure. Anatomy-aware feature encoder (AEFE) extracts anatomy-aware features from each frame independently:\n\n$\\displaystyle \\bar{x}^{i} = \\left( \\bar{x}\\_{feat}^{i}, \\bar{x}\\_{feat,seg}^{i} \\right) = AEFE\\left( I^{i}, c \\right), \\qquad i = 1,\\ldots,10$\n\nDeformable spatio-temporal mamba (DSTM) jointly processes the resulting sequence of features to incorporate temporal context:\n\n$\\displaystyle \\lbrace x^{i}\\rbrace\\_{i=1}^{10} = DSTM\\left( \\lbrace \\bar{x}^{i}\\rbrace\\_{i=1}^{10} \\right),$\n\nand temporal context decoder (TCD) decodes a prediction at each temporal position,\n\n$\\displaystyle \\widehat{Y}\\_{c}^{i} = TCD\\left( x^{i}, \\bar{x}^{i}, c \\right).$\n\nAlthough predictions are available for all 10 frames, the segmentation loss $L\\_{seg}$ is computed only at the annotated position $i = t$. All 10 frames thus contribute to temporal-context modeling, while direct supervision is applied only where ground truth exists. Evaluation follows the same protocol and assesses the prediction corresponding to the annotated target frame. We will clarify the temporal training and evaluation protocol in the revised manuscript.\n\n\n**Q2. Ambiguous anatomy-conditioned segmentation formulation**\n\n**A2.**\n\nAST-Seg predicts a condition-specific binary mask, rather than a single 12-class segmentation map. Given an anatomical condition $c$ and frame $t$, the model outputs the mask prediction $\\widehat{Y}\\_{c}^{t}$ for the queried structure. Accordingly, the ground-truth target in Eq. (17) should be explicitly denoted as $Y\\_{c}^{t}$:\n\n$\\displaystyle \\mathcal{L}\\_{seg} = \\sum\\_{k \\in \\lbrace 1,2\\rbrace} \\left[ \\mathcal{L}\\_{CE}\\left( \\widehat{Y}\\_{c}^{(k),t}, Y\\_{c}^{t} \\right) + \\mathcal{L}\\_{Dice}\\left( \\widehat{Y}\\_{c}^{(k),t}, Y\\_{c}^{t} \\right) \\right].$\n\nAt inference, we query the model using each of the 12 anatomical condition vectors, yielding a segmentation mask prediction per structure. We will revise Eq. (17) and clarify the conditioned segmentation formulation.\n\n**Q3. Incomplete attention supervision formulation**\n\n**A3.**\n\nWe thank the reviewer for identifying this missing implementation detail. The binary affinity matrix $A\\_{b}$ is not directly used as the cross-entropy target. Each query-token row is converted into a valid probability distribution through row-wise normalization:\n\n$\\displaystyle \\bar{A}\\_{b}(i,j) = \\frac{A\\_{b}(i,j)}{\\sum\\_{j'} A\\_{b}(i,j') + \\epsilon}, \\qquad \\epsilon = 10^{-8}.$\n\nThe resulting row of $\\bar{A}\\_{b}$ serves as a target distribution for supervising the predicted attention distribution of the corresponding query target. Rows containing only zeros provide no valid anatomical prior and are therefore excluded from the anatomy-aware attention supervision. We will explicitly clarify this formulation in the revised manuscript."+ },+ "createdAt": "2026-07-30T07:12:18.182Z",+ "modifiedAt": "2026-11-19T17:19:20.463Z",+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=HrC74Wu4XF",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ttthaz1ks/notes/j2dgozfjey.json added
+++ b/reviews/openreview/2ttthaz1ks/notes/j2dgozfjey.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "J2dGoZfjey",+ "replyTo": "daMZo7OgaE",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank Reviewer Qfaa for the constructive and insightful feedback. We address each point below and will incorporate the corresponding clarifications, additional results, and limitations into the revised manuscript.\n\n\n\n**Q1. Anatomy-supervision ablation: Are the gains attributable to increased model capacity or anatomical supervision?**\n\n**A1.**\n\nWe thank the reviewer for this valuable suggestion. To disentangle the effect of model capacity and anatomy supervision, we conducted an additional experiment in which the anatomy attention branches were retained, while the anatomy attention-supervision loss was removed. Importantly, this variant and the fully supervised AEFE have identical architectures, thereby isolating the contribution of the anatomical supervision signal.\n\n\n**Table R1. Ablation study on CAMUS dataset**\n\n| Anatomy branch | Anatomy supervision | DSTM | TCD | LV BP | | | LV wall | | | LA BP | | |\n|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|\n| | | | | **Dice** | **mIoU** | **HD95** | **Dice** | **mIoU** | **HD95** | **Dice** | **mIoU** | **HD95** |\n| – | – | – | – | 90.01 | 82.21 | 5.49 | 84.03 | 72.78 | 6.45 | 87.85 | 78.85 | 8.45 |\n| ✓ | – | – | – | 91.33 | 84.34 | 5.39 | 85.09 | 74.36 | 6.37 | 87.94 | 79.01 | 8.19 |\n| ✓ | ✓ | – | – | 93.32 | 87.56 | 5.04 | 86.77 | 76.82 | 6.21 | 88.64 | 80.09 | 7.84 |\n| ✓ | ✓ | ✓ | – | 94.76 | 90.13 | 4.88 | 88.55 | 79.51 | 5.98 | 89.19 | 81.09 | 7.37 |\n| **✓** | **✓** | **✓** | **✓** | **95.03** | **90.57** | **4.75** | **89.00** | **80.29** | **5.89** | **89.52** | **81.53** | **6.86** |\n\n\nThe extended ablation shows that introducing the additional attention branches without anatomical supervision improves Dice by 0.82 on average across the three structures, and supervising the same branches with anatomy-derived attention priors adds a further 1.46 improvements.\n\nThe results indicate that the improvement of AEFE is not primarily attributed to the increased parameter count. Rather, the explicit anatomy-supervision signal enables the attention branches to learn structurally meaningful cardiac relationships, which accounts for the main source of the observed performance gain. We will include this ablation and the corresponding discussion in the revised manuscript.\n\n\n\n**Q2. Annotation protocol and quality control**\n\n**A2.**\n\nWe are pleased to provide further details on the annotation process. The EA dataset was annotated by three experienced sonographers and an expert physician, whereas the PoC-Echo dataset was annotated by one experienced sonographer and an expert physician.\n\nTo ensure accurate and consistent ground-truth, we have annotated the dataset with the following four-stage protocol: (1) annotator training, (2) initial annotation, (3) expert review, and (4) revision. Prior to annotation, the sonographers were trained with a standardized manual in accordance with the recommendations of the American Society of Echocardiography and the European Association of Cardiovascular Imaging. As part of the training process, the labelers annotated representative training cases and received feedback to promote consistent and accurate delineation. After training, each study case was annotated by a sonographer and independently reviewed by the expert physician, who either approved the annotation or returned it for revision. Cases returned for revision were refined through discussion between the annotating sonographer and the expert physician. As suggested, we will add a detailed description of the dataset in the main section of revised manuscript.\n\n**Q3. Scope of domain generalization**\n\n**A3.**\n\nTo evaluate out-of-distribution robustness, we curated the PoC-Echo dataset using representative portable ultrasound devices. Compared with high-end console-based echocardiography systems commonly used in clinical practice, portable devices typically produce images with lower spatial resolution, reduced signal-to-noise ratio, and more pronounced artifacts. We therefore used PoC-Echo as an external domain-shift benchmark.\n\nWe agree that evaluation on a single external dataset does not establish universal domain generalization. A more comprehensive assessment would require additional validation across institutions, operator experience levels, and artifact types. In the revised manuscript we will accordingly restate our claim as improved robustness under the evaluated portable-device domain shift and will discuss broader multi-institutional and multi-domain validation as an important direction for future work."+ },+ "createdAt": "2026-07-30T06:52:30.918Z",+ "modifiedAt": "2026-11-19T17:19:20.639Z",+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=J2dGoZfjey",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ttthaz1ks/notes/lg2vipezry.json added
+++ b/reviews/openreview/2ttthaz1ks/notes/lg2vipezry.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "lg2VIpEzrY",+ "replyTo": "CmKA54xtjp",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "**Q4 Training and testing splits for each experiment?**\n\n**A4.**\n\nFor the publicly available CAMUS benchmark, we adopt the official case-level split of the dataset. The proposed EA dataset is split at the case level, with 19,125 samples for training and 2,410 samples for testing. PoC-Echo contains 259 samples and is used exclusively for external evaluation.\n\nFor all experiments reported in Tables 1–4, the comparative baselines and the proposed models are trained using the combined CAMUS and EA training sets. Table 5 assesses two training configurations which are CAMUS only, and the combined CAMUS and EA training sets. Table 1 reports evaluation on the CAMUS and PoC-Echo test sets, Table 2 reports evaluation on the EA test set, Tables 3 and 4 report evaluation on the CAMUS test set, and Table 5 reports evaluation on the PoC-Echo test set.\n\n**Q5. Disentangling training-set size from the contribution of EA (Appendix C.2)**\n\n**A5.**\n\nWe agree with the reviewer that disentangling the gain attributable to the increased number of training samples from the contribution of the EA dataset itself would enable a more rigorous evaluation. To this end, we conducted an additional experiment in which the total number of training samples is held constant: we halved the CAMUS training set and replaced the removed 800 samples with 800 samples randomly sampled from the EA dataset.\n\n**Table R4.Effect of the EA dataset under an identical total number of training sample**\n| Method | Training dataset | PoC-Echo (OOD) – LV BP | | |\n|:--|:--|:--|:--|:--|\n| | | **mDice** | **mIoU** | **HD95** |\n| U-Net | CAMUS (1,600) | 61.49 | 49.83 | 47.47 |\n| | CAMUS (800) + EA (800) | 71.08 | 60.58 | 31.87 |\n| SwinUNet | CAMUS (1,600) | 66.15 | 53.04 | 51.93 |\n| | CAMUS (800) + EA (800) | 73.43 | 61.62 | 41.64 |\n| MSA | CAMUS (1,600) | 76.80 | 64.71 | 31.24 |\n| | CAMUS (800) + EA (800) | 81.37 | 70.59 | 24.68 |\n| SAMed | CAMUS (1,600) | 78.40 | 66.35 | 28.21 |\n| | CAMUS (800) + EA (800) | 81.02 | 70.22 | 24.52 |\n| SAMUS | CAMUS (1,600) | 82.71 | 74.47 | 17.96 |\n| | CAMUS (800) + EA (800) | 84.64 | 77.16 | 16.54 |\n\nAs shown in Table, incorporating the EA dataset yields consistently higher OOD performance on PoC-Echo, even though the total number of training samples remains identical. The results indicate that the observed improvement is not merely a consequence of enlarging the training set. The diverse ultrasound vendors and acquisition environments covered by the EA dataset enable more generalized Echo segmentation."+ },+ "createdAt": "2026-07-30T07:23:00.890Z",+ "modifiedAt": "2026-11-19T17:19:20.361Z",+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=lg2VIpEzrY",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ttthaz1ks/notes/lnkefvchfg.json modified
+++ b/reviews/openreview/2ttthaz1ks/notes/lnkefvchfg.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair tdXk","content": {- "metareview": "- Reviewers generally view this as a strong use inspired paper with a clinically meaningful Echo segmentation target.\n- The EA dataset and broad anatomical coverage are a major part of the contribution.\n- The main requested clarification is the temporal protocol: 10-frame clips versus one annotated frame per video.\n- Reviewers also ask for stronger evidence that anatomy supervision, not just model capacity/pretraining scale, drives the gains.\n- Empirical results support improved segmentation, but OOD and clinical utility claims are narrower than stated.\n- Dataset/code release and annotation quality details are important for impact and reproducibility."+ "metareview": "- Reviewers generally view this as a strong use inspired paper with a clinically meaningful Echo segmentation target.\n- The EA dataset and broad anatomical coverage are a major part of the contribution.\n- The main requested clarification is the temporal protocol: 10-frame clips versus one annotated frame per video.\n- Reviewers also ask for stronger evidence that anatomy supervision, not just model capacity/pretraining scale, drives the gains.\n- Empirical results support improved segmentation, but OOD and clinical utility claims are narrower than stated.\n- Dataset/code release and annotation quality details are important for impact and reproducibility.",+ "final_justification": "Overall, there is an agreement among all reviewers that the paper should be accepted."},"createdAt": "2026-07-21T15:06:04.577Z",- "modifiedAt": "2026-11-18T15:20:45.873Z",+ "modifiedAt": "2026-11-19T05:00:29.817Z","url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=LnKEFvChfG","license": "CC-BY-4.0"}
reviews/openreview/2ttthaz1ks/notes/psr1h5mr9u.json added
+++ b/reviews/openreview/2ttthaz1ks/notes/psr1h5mr9u.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "PSr1H5mR9u",+ "replyTo": "8GnEAgHpIu",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We are grateful to Reviewer SDjc for the constructive feedback. We address each point below and will incorporate the corresponding clarifications, and revisions into the manuscript\n\n**Q1. Distinction between training and inference, and feasibility under clinically accessible computational resources.**\n\n**A1.**\n\nWe thank the reviewer for raising this important question and for requesting a clearer distinction between the training and inference procedures. We would like to clarify that the computational requirements of AST-Seg differ substantially between the training and inference stages. Training involves large-scale pretraining on 7.9M echocardiographic frames, anatomy-aware representation learning, and end-to-end optimization, and therefore benefits from high-end accelerators. In contrast, inference requires only a forward pass through the trained model with significantly smaller batch size. Consequently, the computational and memory requirements are substantially lower.\n\nTo assess deployment feasibility using hardware representative of practical clinical settings, we measured the inference latency, throughput, and peak GPU memory consumption of AST-Seg on NVIDIA RTX 4090 and RTX 3090 GPUs. As summarized below, AST-Seg achieved real-time throughput on both devices, while requiring under 1 GB of GPU memory.\n\n**Table R1. Computational cost experiments**\n| Method | NVIDIA RTX 4090 | | NVIDIA RTX 3090 | | Peak GPU memory |\n|:--|:--|:--|:--|:--|:--|\n| | **Latency / frame** | **Frame / second** | **Latency / frame** | **Frame / second** | |\n| **AST-Seg** | 15.1 ms | 66 FPS | 25.8 ms | 39 FPS | 947 MB |\n\nThe results demonstrate that AST-Seg can be deployed on widely available consumer- or workstation-grade hardware rather than the accelerators used during training.\n\n**Q2. Clear description of Figure 4**\n\n**A2.**\n\nWe appreciate the opportunity to clarify this point. Figure 4 visualizes the spatial attention distribution associated with each representative query point. We would like to clarify that the marked points are not intended to represent segment centroids. The marked points indicate the selected query locations whose attention patterns are being examined. For each query point, the corresponding map displays the attention weights over all spatial positions.\n\nAST-Seg assigns higher attention to spatially coherent regions belonging to the same semantic anatomy as the query, indicating that the proposed encoder captures anatomical relationships in echocardiographic images through anatomy-aware representation learning.\n\nIn contrast, DINOv3, which is not trained with anatomy-aware representation learning, instead appears to attend primarily to regions of similar pixel appearance rather than to regions sharing a common anatomical identity.\n\nWe will revise the figure caption and the accompanying description to state the interpretation explicitly.\n\n**Q3. Rationale for using DSTM as a refinement stage**\n\n**A3.**\n\nAccurate segmentation in echocardiography requires both a faithful interpretation of the target frame and effective use of temporal anatomical context, and we found it beneficial to assign these two roles to separate stages. The first stage predicts a coarse mask from the current-frame features (Eq. 14), anchoring the segmentation to the instantaneous appearance of the target frame. The second stage refines this prediction by integrating the target-frame representation with the temporally aggregated DSTM features (Eq. 15). The proposed design preserves frame-specific spatial detail while exploiting temporal context to resolve ambiguous boundaries and mitigate transient appearance variations.\n\nTo validate the design, Table 3 of the main manuscript compares the proposed decoder against a variant in which the temporally aggregated and current-frame features are combined in a single stage, without two-stage refinement.\n\nThe refinement scheme provided enhanced cardiac segmentation, supporting the effectiveness of the proposed two-stage decoding scheme.\n\n**Table R2. Quantitative assessments on CAMUS dataset**\n\n| Decoder (AST-Seg) | LV BP | | | LV wall | | | LA BP | | |\n|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|\n| | **Dice** | **mIoU** | **HD95** | **Dice** | **mIoU** | **HD95** | **Dice** | **mIoU** | **HD95** |\n| w/o refinement | 94.76 | 90.13 | 4.88 | 88.55 | 79.51 | 5.98 | 89.19 | 81.09 | 7.37 |\n| **proposed** | **95.03** | **90.57** | **4.75** | **89.00** | **80.29** | **5.89** | **89.52** | **81.53** | **6.86** |"+ },+ "createdAt": "2026-07-30T08:04:28.812Z",+ "modifiedAt": "2026-11-19T17:19:20.037Z",+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=PSr1H5mR9u",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ttthaz1ks/notes/sp6ev2goyp.json added
+++ b/reviews/openreview/2ttthaz1ks/notes/sp6ev2goyp.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "sP6EV2GOyP",+ "replyTo": "V6RyLE7Dj7",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank Reviewer qsR1 for the thorough review and constructive feedback. We address each comment below and will incorporate the requested experiments, implementation details, and clarifications into the revised manuscript.\n\n**Q1. Dataset and code release.**\n\n**A1.**\n\nWe thank the reviewer for emphasizing the importance of code and dataset release. We agree that broad access to the EA dataset would enhance the impact and reproducibility of this work. Because the EA dataset is derived from clinical echocardiographic examinations, open release of the dataset requires additional institutional approval under the data-governance policies. We are currently preparing the necessary materials for institutional approval for open access of the dataset, and we are committed to releasing the dataset as broadly as the approval permits.\n\nTo further support reproducibility, we will publicly release the code including training, evaluation, pre-processing, and experiment scripts with detailed instructions.\n\n\n**Q2. Justification of the rigid anatomical prior**\n\n**A2.**\n\nWe agree that the anatomical prior should not impose an overly deterministic relational structure on the learned attention. For this reason, the attention distributions in Eq. 9 are supervised with a smoothed cross-entropy [1], so that the affinity prior functions as a relaxed regularizer guiding intra-structure connectivity rather than as a hard constraint.\n\nFigure 4-(b) presents the resulting attention maps of AST-Seg. The learned affinity pattern does not collapse onto the binary target, but instead exhibits continuous, spatially graded responses while preserving anatomical organization.\n\n\nReference \n\n[1] Szegedy, Christian, et al. \"Rethinking the inception architecture for computer vision.\" *Proceedings of the IEEE conference on computer vision and pattern recognition*. 2016.\n\n**Q3. Phase awareness of DSTM**\n\n**A3.**\n\nWe appreciate the reviewer’s insightful question. Each EA dataset sample is constructed from an echocardiography sequence covering one complete cardiac cycle. Since the number of acquired frames varies across cases with heart rate and acquisition frame rate, we uniformly subsample $T = 10$ chronologically ordered frames over the full cycle. Consequently, the DSTM receives a temporally normalized representation of a single cardiac cycle rather than a fixed-duration window covering an inconsistent fraction of the cycle. We will clarify this sampling protocol in the revised manuscript.\n\n\n**Q4. Disentangling pretraining bias from architectural gains**\n\n**A4.**\n\n**Table R1. Quantitative assessment of AST-Seg on CAMUS dataset**\n\n| Model | Encoder initialization | LV BP | | | LV wall | | | LA BP | | |\n|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|:--|\n| | | **Dice** | **mIoU** | **HD95** | **Dice** | **mIoU** | **HD95** | **Dice** | **mIoU** | **HD95** |\n| AST-Seg | Random initialization | 93.29 | 87.55 | 5.03 | 87.31 | 77.59 | 6.13 | 88.43 | 79.81 | 7.81 |\n| AST-Seg | MIM pretraining | 94.02 | 88.81 | 4.92 | 88.03 | 78.73 | 6.05 | 88.96 | 80.63 | 7.47 |\n|**AST-Seg** | **Proposed anatomy representation learning** | **95.03** | **90.57** | **4.75** | **89.00** | **80.29** | **5.89** | **89.52** | **81.53** | **6.86** |\n\nWe thank the reviewer for this important suggestion. To separate the contribution of large-scale MIM pretraining from that of anatomy-aware representation learning, we evaluated AST-Seg under three encoder initialization schemes, which are random initialization, MIM pretraining on the 7.9M-frame Echo dataset without anatomy-aware supervision, and the proposed representation learning strategy combining MIM pretraining with anatomy-aware attention supervision.\n\nLarge-scale MIM pretraining consistently improves performance over random initialization, confirming the benefit of domain-specific pretraining. Importantly, incorporating anatomy-aware representation learning yields further improvements. The results indicate that the performance of AST-Seg is not attributable solely to the scale of MIM pretraining. The proposed anatomical supervision provides a measurable contribution. We will include this ablation and clarify the respective roles of MIM pretraining and anatomy-aware learning in the revised manuscript."+ },+ "createdAt": "2026-07-30T07:58:27.803Z",+ "modifiedAt": "2026-11-19T17:19:20.440Z",+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=sP6EV2GOyP",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ttthaz1ks/notes/wdgddeudzj.json added
+++ b/reviews/openreview/2ttthaz1ks/notes/wdgddeudzj.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "WdgdDeudZj",+ "replyTo": "8GnEAgHpIu",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "**Q4. How the positional embedding is created and trained**\n\n**A4.**\n\nWe thank the reviewer for highlighting the need to clarify the embedding mechanism. The anatomical condition $c$ is represented as a one-hot vector and provided as an input to AST-Seg. A learnable embedding matrix projects $c$ into the model’s feature space. The resulting embedding is incorporated into the conditioned anatomy branch of AEFE, where it modulates the ultrasound feature representation used as the key and value of the conditioned cross-attention (Eq. 4), thereby guiding the extracted features toward the target anatomical structure. The embedding matrix is optimized jointly with the other AST-Seg parameters during anatomy-aware representation learning and down-stream training."+ },+ "createdAt": "2026-07-30T08:04:09.768Z",+ "modifiedAt": "2026-11-19T17:19:20.051Z",+ "url": "https://openreview.net/forum?id=2TtThaZ1Ks¬eId=WdgdDeudZj",+ "license": "CC-BY-4.0"+}