A World Model of Radiologist Reading for Medical Image Representation Learning
Update NeurIPS 2026 submission DJzM2q9amM: 10 notes
@openreview[bot] · 2026-11-24 15:47 UTC · 8d45787dffd4 ·
reviews/openreview/djzm2q9amm/notes/b7dh8cwnkh.json added
+++ b/reviews/openreview/djzm2q9amm/notes/b7dh8cwnkh.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "B7dH8cwNkH",+ "replyTo": "fwAO6GStKM",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "**W2: Clarification on Future-Representation Prediction.**\n\nWe thank the reviewer for this important follow-up. We agree with the key distinction: previously observed regions may provide sufficient context to anticipate **where** a radiologist is likely to attend next, but they cannot necessarily determine **what abnormality** is present in an unseen region. Our objective does not assume otherwise.\n\nSpecifically, the representation of the future fixation region is computed from the actual future patch by the **target encoder** and serves only as a **training target**. The predictor does **not observe this future patch**; it predicts its latent representation from the accumulated observations. Thus, the objective should not be interpreted as reconstructing the unseen abnormality. Rather, it encourages the context representation to capture the **predictable component** of a future expert-attended region. Visual information that is unique to the unseen region is inherently unpredictable from the preceding observations and is not expected to be recovered.\n\nThis distinction also motivates combining **spatial gaze dynamics** with **representation prediction**: the fixation trajectory provides supervision for **where the expert searches**, while latent prediction encourages the model to learn **contextual dependencies between sequentially attended regions**. We will clarify this interpretation in the manuscript and avoid wording that could imply that the model predicts an unseen abnormality before it is observed."+ },+ "createdAt": "2026-08-01T15:40:29.747Z",+ "modifiedAt": "2026-11-19T17:12:06.396Z",+ "url": "https://openreview.net/forum?id=DJzM2q9amM¬eId=B7dH8cwNkH",+ "license": "CC-BY-4.0"+}
reviews/openreview/djzm2q9amm/notes/ba3fpjjplq.json added
+++ b/reviews/openreview/djzm2q9amm/notes/ba3fpjjplq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "ba3FpJJPlQ",+ "replyTo": "hOIoPC1yuj",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer hqQ1,\nThank you again for your time and constructive feedback. \n\nPlease let us know if you have any remaining questions or concerns. We are more than happy to address them before the discussion period ends. \nBest regards,\nThe Authors"+ },+ "createdAt": "2026-08-02T13:33:00.345Z",+ "modifiedAt": "2026-11-19T17:12:06.394Z",+ "url": "https://openreview.net/forum?id=DJzM2q9amM¬eId=ba3FpJJPlQ",+ "license": "CC-BY-4.0"+}
reviews/openreview/djzm2q9amm/notes/e1ixpofgox.json modified
+++ b/reviews/openreview/djzm2q9amm/notes/e1ixpofgox.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair fwVu","content": {- "metareview": "All reviewers generally appreciate the methods and the results. However, concerns remain related to: unsubstantiated claims and small gains (hqQ1, rFvu); limited application (chest xray) and single eye-tracking corpus (rFvu), backbone dependence (rFvu); no comparisons with non-gaze-supervised SSL methods (G9bE), how pre-processing may lose information (rFvu), and lack of quantitative localization analysis (rFvu). Also, there is lack of info about radiologists involved and whether their scan paths are representative (hqQ1), and whether the model truly capture radiologist reasoning ands search patterns (G9bE). Finally, rFvu is curious how may the approach work for 3D volumetric data. Reviews generally leaning towards acceptance with 2xBA and 1xBR."+ "metareview": "All reviewers generally appreciate the methods and the results. However, concerns remain related to: unsubstantiated claims and small gains (hqQ1, rFvu); limited application (chest xray) and single eye-tracking corpus (rFvu), backbone dependence (rFvu); no comparisons with non-gaze-supervised SSL methods (G9bE), how pre-processing may lose information (rFvu), and lack of quantitative localization analysis (rFvu). Also, there is lack of info about radiologists involved and whether their scan paths are representative (hqQ1), and whether the model truly capture radiologist reasoning ands search patterns (G9bE). Finally, rFvu is curious how may the approach work for 3D volumetric data. Reviews generally leaning towards acceptance with 2xBA and 1xBR.",+ "final_justification": "I have read the authors' responses to the reviews. The reviewers have largely addressed the concerns raised by the reviewers. The issues of testing on other datasets, extending to 3D, intra-rater variability, and relating the findings to radiologist chain of reasoning, are very important indeed, but, still, the paper does succeed in presenting \"novel, high potential reward idea with scope beyond what can be validated in a single paper\" i.e. passing the bar for a \"Concept and Feasibility\" Contribution paper."},"createdAt": "2026-07-22T04:55:57.507Z",- "modifiedAt": "2026-11-18T15:20:55.251Z",+ "modifiedAt": "2026-11-19T05:00:34.515Z","url": "https://openreview.net/forum?id=DJzM2q9amM¬eId=e1iXPOFGOx","license": "CC-BY-4.0"}
reviews/openreview/djzm2q9amm/notes/ean4jqxtg5.json added
+++ b/reviews/openreview/djzm2q9amm/notes/ean4jqxtg5.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Ean4JQxtG5",+ "replyTo": "XNq9HPn90F",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you very much for taking the time from your busy research schedule to provide us with such thoughtful and constructive feedback. Your comments have been very helpful in improving both the clarity and quality of our work. We will continue to further strengthen the manuscript and the work itself, and we hope it can ultimately have a broader impact. We sincerely appreciate your time and consideration."+ },+ "createdAt": "2026-08-01T16:53:21.831Z",+ "modifiedAt": "2026-11-19T17:12:06.195Z",+ "url": "https://openreview.net/forum?id=DJzM2q9amM¬eId=Ean4JQxtG5",+ "license": "CC-BY-4.0"+}
reviews/openreview/djzm2q9amm/notes/eecwxyf0jl.json added
+++ b/reviews/openreview/djzm2q9amm/notes/eecwxyf0jl.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "eECwXyF0Jl",+ "replyTo": "IdKINc1PXM",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer rFvu,\nThank you again for your time and constructive feedback. \n\nPlease let us know if you have any remaining questions or concerns. We are more than happy to address them before the discussion period ends. \nBest regards,\nThe Authors"+ },+ "createdAt": "2026-08-02T13:33:39.895Z",+ "modifiedAt": "2026-11-19T17:12:06.394Z",+ "url": "https://openreview.net/forum?id=DJzM2q9amM¬eId=eECwXyF0Jl",+ "license": "CC-BY-4.0"+}
reviews/openreview/djzm2q9amm/notes/fwao6gstkm.json added
+++ b/reviews/openreview/djzm2q9amm/notes/fwao6gstkm.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "fwAO6GStKM",+ "replyTo": "O6llmArJq3",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer G9bE",+ "content": {+ "title": "Comment by Reviewer",+ "comment": "Thank you for your response. I think your explanations for W1/Q1 and W3/Q3 have addressed my concerns. Overall, I find your proposal both interesting and novel.\n\nI have one remaining question regarding W2. I think that based on the previously observed regions, the model should only be able to predict which region to attend to next. It seems that the model would first need to observe the future fixation region to determine whether any abnormality is present and construct a meaningful representation of that region.\n\nIn the medical setting, I feel that information from the previously observed regions is sufficient to infer where a clinician is likely to look next, but not what abnormality exists in that unseen region. Therefore, I'm not sure how your model can generate a meaningful embedding for the future fixation region directly before it has actually observed that region.\n\nCould you explain this part in more detail? I feel I may be missing something about how the future region representations are learned or constructed."+ },+ "createdAt": "2026-08-01T14:43:39.163Z",+ "modifiedAt": "2026-11-19T17:12:06.558Z",+ "url": "https://openreview.net/forum?id=DJzM2q9amM¬eId=fwAO6GStKM",+ "license": "CC-BY-4.0"+}
reviews/openreview/djzm2q9amm/notes/l0uakimplv.json added
+++ b/reviews/openreview/djzm2q9amm/notes/l0uakimplv.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "L0UAKIMPLV",+ "replyTo": "ba3FpJJPlQ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer hqQ1",+ "content": {+ "title": "Appropriate evaluation across scanpaths from multiple radiologists is needed.",+ "comment": "The reliance on a single corpus remains a significant concern. This issue is also related to the response to Q2(4). Regardless of whether the model predicts the next gaze coordinate or the next image patch, inter-radiologist variability remains an important factor. The authors claim that radiologists may share common anatomical and diagnostic search patterns, but is there evidence to support this claim? Even if this is generally true, individual radiologists may still have different search preferences and produce substantially different scanpaths. For example, if the model were retrained using another radiologist’s scanpaths, would its performance change or potentially decrease? Without appropriate evaluation across scanpaths from multiple radiologists, or a feasible method for combining or harmonising their scanpaths, it is not convincing that the proposed approach would be useful in real-world clinical settings. Therefore, my score remains unchanged."+ },+ "createdAt": "2026-08-03T01:30:47.552Z",+ "modifiedAt": "2026-11-19T17:12:06.389Z",+ "url": "https://openreview.net/forum?id=DJzM2q9amM¬eId=L0UAKIMPLV",+ "license": "CC-BY-4.0"+}
reviews/openreview/djzm2q9amm/notes/lvbek0y6vb.json added
+++ b/reviews/openreview/djzm2q9amm/notes/lvbek0y6vb.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "lvBek0y6Vb",+ "replyTo": "L0UAKIMPLV",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the thoughtful follow-up and for highlighting the important issue of inter-radiologist variability. We agree that different radiologists may exhibit distinct scanpath preferences, and that evaluation across multiple independent eye-tracking cohorts would provide stronger evidence of generalizability.\n\nAt present, however, this question cannot be fully resolved because sufficiently large public eye-tracking datasets from multiple radiologists and institutions remain very limited. More generally, representation learning does not require every training observation to be free of observer-specific or noisy signals; with sufficient data, the objective is to capture statistical structure that is shared across observations rather than reproduce every individual trajectory. In our setting, the gaze sequences are derived from MIMIC-EYE and further processed following the GazeSearch protocol, which removes part of the fixation noise and standardizes the scanpaths before training.\n\nMore importantly, the learned supervision already shows consistent transfer beyond gaze prediction itself. It improves both scanpath-related prediction and downstream lesion recognition/localization, and the gains are consistently observed across multiple backbone architectures. These results suggest that the model is not merely memorizing an individual radiologist’s exact search preference, but is learning visual and spatial regularities that remain useful for downstream tasks.\n\nWe therefore agree that multi-radiologist and cross-institution validation is an important next step and will explicitly state this as a limitation. As larger and more diverse eye-tracking datasets become available, our framework can naturally incorporate scanpaths from multiple observers during pretraining, which we expect will further improve robustness to individual variability and strengthen its potential clinical applicability."+ },+ "createdAt": "2026-08-03T01:41:08.980Z",+ "modifiedAt": "2026-11-19T17:12:06.097Z",+ "url": "https://openreview.net/forum?id=DJzM2q9amM¬eId=lvBek0y6Vb",+ "license": "CC-BY-4.0"+}
reviews/openreview/djzm2q9amm/notes/uswmdvoz03.json added
+++ b/reviews/openreview/djzm2q9amm/notes/uswmdvoz03.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "UsWmDVOz03",+ "replyTo": "e1iXPOFGOx",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to the Meta-Review",+ "comment": "We sincerely thank the Area Chair and reviewers for their constructive feedback and encouraging assessment. We have addressed the major concerns as follows:\n\n**Claims, small gains, statistical reliability, and radiologist expertise:** addressed in **hqQ1: Q1–Q2**, **rFvu: W5/Q2**, and **G9bE: W1/Q1**. We clarify the dataset and radiologist setting, moderate the “reasoning” and “self-supervised” claims, add five-seed uncertainty estimates, and provide stronger temporal-order evidence.\n\n**Single eye-tracking corpus, chest-X-ray scope, and extension to 3D modalities:** addressed in **hqQ1: Q1** and **rFvu: W2/Q5**. We acknowledge the current data limitation and explain how the formulation can extend to fixated slices or 3D patches in CT/MRI and temporally ordered observations in ultrasound.\n\n**Backbone dependence:** addressed in **rFvu: W3/Q4**, with additional experiments using MedCLIP, EGMA, DINOv3, CheXWorld, and a randomly initialized Swin backbone. Comparison with gaze-free SSL methods: addressed in **G9bE: W3/Q2**, with new 1%, 10%, and 100% linear-probe comparisons against CheXWorld, MedMAE, and LVM-Med.\n\n**Potential temporal-information loss during gaze preprocessing:** addressed in **hqQ1: Q2(4)** and **rFvu: W1/Q1**. We clarify that only duplicate gaze samples mapping to the same patch within a time step are merged, while observations across time remain distinct through temporal embeddings.\n\n**Quantitative localization:** addressed in **rFvu: W4/Q3**, with new pointing-game, IoU, and Dice evaluations using RSNA bounding boxes and SIIM-ACR masks.\n\n**Whether the model captures expert search dynamics:** addressed in **hqQ1: Q2(2)** and **G9bE: W1/Q1–W2**, including real-gaze versus raster- and random-order ablations. We also revise the claim to the more precise “expert gaze-guided evidence-acquisition dynamics.”\n\nWe will incorporate these new experiments, clarifications, and moderated claims into the revised manuscript."+ },+ "createdAt": "2026-07-29T19:18:58.669Z",+ "modifiedAt": "2026-11-19T17:12:06.884Z",+ "url": "https://openreview.net/forum?id=DJzM2q9amM¬eId=UsWmDVOz03",+ "license": "CC-BY-4.0"+}
reviews/openreview/djzm2q9amm/notes/xnq9hpn90f.json added
+++ b/reviews/openreview/djzm2q9amm/notes/xnq9hpn90f.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "XNq9HPn90F",+ "replyTo": "B7dH8cwNkH",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer G9bE",+ "content": {+ "title": "Comment by Reviewer",+ "comment": "Thank you for your response. I think your explanations have addressed my concerns. This design look interesting, so I will increase my score."+ },+ "createdAt": "2026-08-01T16:18:10.155Z",+ "modifiedAt": "2026-11-19T17:12:06.391Z",+ "url": "https://openreview.net/forum?id=DJzM2q9amM¬eId=XNq9HPn90F",+ "license": "CC-BY-4.0"+}