Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation
Import NeurIPS 2026 submission 1NmpaqEwkP: 10 notes
@openreview[bot] · 2026-11-22 17:53 UTC · 2b705f4c04c5 ·
reviews/openreview/1nmpaqewkp/forms.json added
+++ b/reviews/openreview/1nmpaqewkp/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/bbicqxbrrr.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/bbicqxbrrr.json@@ -0,0 +1,31 @@+{+ "schema": "review/1",+ "id": "BBICqXBrrr",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer wsWG",+ "content": {+ "summary": "The paper proposes a new method for translating physiological signals, such as PPG and SCG, from one body location to another. The main idea is to better respect the repeating, wave-like structure of these signals by modeling their phase and amplitude in a geometry-aware way. The authors show that this helps produce more accurate translated waveforms than standard interpolation-based flow matching and direct supervised prediction on their PPG and SCG benchmarks.",+ "contribution_type": "use_inspired",+ "strengths_and_weaknesses": "The paper is well motivated and addresses a practical problem in wearable physiological sensing. The proposed method is carefully designed around the structure of heartbeat-like signals, rather than treating them as ordinary time series. I also appreciate that the authors compare against several reasonable baselines and evaluate on two different signal translation tasks.\n\nThe main strength is that the method is both intuitive and empirically supported: if physiological signals have repeating cycles, then using a representation that respects cycles makes sense. The results show consistent improvements, especially on the SCG task.\n\nThe main weakness is that the evaluation is still somewhat limited. The datasets are small and appear to come from a single institution, so it is not clear how well the method would generalize to different sensors, populations, or recording conditions. Also, the metrics mostly measure waveform similarity. Since the motivation is medical or physiological monitoring, it would be helpful to evaluate whether important clinical features are preserved better as well.\n\nThe paper is generally clear, though some details may be too technical for readers outside this area. A simpler explanation of when the method might fail would improve the presentation.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "Can the authors show whether the improvements hold for most subjects, rather than only in the average result?\n\nCan the authors evaluate clinically meaningful features, not only waveform-distance metrics? For example, do the translated signals better preserve important timing or morphology markers?\n\nHow well would the method work on data from a different device, institution, or population?\n\nWhich part of the method contributes most to the improvement? A simpler ablation would help clarify this.\n\nAre there cases where the method fails, such as noisy signals or very weak signal amplitude?",+ "limitations": "- The evaluation is based on relatively small datasets.\n- The datasets appear to come from a single institution, so it is unclear how well the method would generalize to other sensors, populations, or recording conditions.\n- The reported metrics mainly measure waveform similarity, but they do not fully show whether clinically meaningful features are preserved.\n- More ablation studies would be helpful to show which part of the method contributes most to the improvement.\n- The method may be sensitive to noisy or weak signals, especially when the signal amplitude is low and phase information becomes unreliable.",+ "rating": 4,+ "confidence": 2,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "n/a",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes"+ },+ "createdAt": "2026-06-29T03:12:54.285Z",+ "modifiedAt": "2026-11-18T13:38:47.602Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=BBICqXBrrr",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/bcz8yqahsm.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/bcz8yqahsm.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "bcZ8yQahsm",+ "replyTo": "UAFC6X9b1H",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "### We thank the reviewer for the detailed assessment. We address each point below.\n\n### 1. Is the improvement due to preprocessing rather than the generative formulation?\n\nThe performance difference is not caused by preprocessing or temporal alignment applied only to our method. All methods use the same filtering, resampling, synchronization across devices, beat/window extraction, artifact rejection, center cropping, and normalization. The Hilbert naive baseline tests whether the improvement follows simply from using phase–amplitude coordinates. Its weaker performance shows that the Hilbert representation alone is insufficient. Unlike the bounded circular embedding $(\\cos\\phi, \\sin\\phi)$, its unwrapped Euclidean phase coordinate is unbounded and can assign arbitrarily large squared error to phase excursions, particularly in regions of low amplitude. Complementarily, improvement over affine flow matching in the time domain indicates that the benefit is not explained by flow matching alone, but is associated with the geometry used to construct the probability path and vector field.\n\n### 2. Validity of the product manifold assumption under phase–amplitude coupling\n\nThe method does not assume that phase and amplitude are statistically independent or physiologically uncoupled. The conditional vector field network receives both jointly and can learn coupled phase–amplitude dynamics. The representation introduces only a geometric inductive bias by modeling phase on the circular domain $S^1$ and amplitude on the positive half line $\\mathbb{R}_{>0}$. We will revise any language that could be interpreted as assuming strict physical separability.\n\nRecordings from exercise recovery/resistive breathing introduce meaningful cardiovascular variation and variation related to motion, but they do not represent the full range of conditions encountered in deployment. Stronger motion artifacts, distortions that depend on the sensor, and phase–amplitude coupling should therefore be evaluated in future work using datasets that are larger, noisier, and span more devices and institutions.\n\n### 3. Baselines\n\nWe agree that broader comparisons with modern generative and alignment methods would expand the empirical scope. The current baselines were selected as controlled ablations under a shared backbone and training protocol. Direct supervised prediction removes the probability path entirely, leaving one endpoint residual per pair; affine flow matching restores the path but keeps the raw waveform as the state, so the bridge is the standard Euclidean path; Hilbert naive flow matching adopts the phase–amplitude coordinates but treats them as Euclidean, with unwrapped phase, linear interpolation; and our method adds the cylindrical representation, geodesic bridge, and intrinsic tangent vector field.\n\nWe will clarify that these experiments are intended to isolate the contribution of the proposed geometry rather than establish superiority over all generative methods for time series, and we acknowledge comparisons with broader diffusion, autoregressive, registration, and shape analysis approaches as an important extension of the empirical evaluation.\n\n### 4. Cohort size and absence of pathological conditions\n\nWe agree that the limited cohort size and data collection at a single institution restrict the generalizability of the findings. The PPG cohort comprises 20 subjects and 11,483 windows, while the SCG cohort comprises 13 subjects across 24 sessions and 30,494 beats. Validation and test sets share no subjects, which prevents leakage at the subject level, and evaluation over four random seeds assesses sensitivity to initialization and data partitioning. However, these measures do not replace external validation on a larger cohort drawn from multiple institutions, and we will strengthen this limitation.\n\nTo further show the robustness, we have computed the per-subject, per-seed breakdown for both datasets, scoring each evaluation by the model with the lowest mean error. On PPG, the four held-out splits cover 11 distinct test subjects and 20 subject–seed evaluations, giving 60 comparisons across the three metrics under each transform. The cylindrical geodesic path is best in 52 of the 60 comparisons under the standard Hilbert transform (16/20 on DTW, 18/20 on $L_2$, 18/20 on HT distance) and in 51 of the 60 under the Extended Hilbert transform (17/20 on DTW, 16/20 on $L_2$, 18/20 on HT distance). On SCG under limited-support adaptation, the four splits cover 7 distinct test subjects and 12 subject–seed evaluations, giving 36 comparisons per transform, and the cylindrical geodesic path is best in 33 of the 36 under the standard Hilbert transform (11/12 on DTW, 11/12 on $L_2$, 11/12 on HT distance) and in 34 of the 36 under the Extended Hilbert transform (12/12 on DTW, 11/12 on $L_2$, 11/12 on HT distance). Our model is therefore the most frequent winner for both datasets.\n\nRegarding pathology, all participants were healthy, and we will state this explicitly. That said, the recordings are not resting baselines. The protocols apply stressors, exercise recovery and resistive breathing, that drive heart rate, respiratory effort, and hemodynamics across a wide range within each session, together with the associated motion. The translation must therefore track the source signal consistently under changing physiological state rather than reproduce a single stationary morphology. Prior literature has shown that such perturbations are representative of the types of physiological changes that are meaningful from a clinical standpoint, such as the changes in signal characteristics in patients with PTSD following stressors.\n\nThe task is also not smooth interpolation between near-identical signals. Source and target are recorded at different sensing locations and differ in both timing and morphology, and our main results report the untranslated source waveform as a reference, so the error that the translation must remove is quantified directly. We agree that evaluation on pathological cohorts, where morphology departs further from the healthy range, is a necessary next step, and we will list it in the limitations.\n\n### 5. New framework or geometry-aware reparameterization?\n\nWe agree that our method remains within the conditional flow matching framework, and we do not claim to introduce a new class of generative model. Its distinction from existing manifold flow matching lies in how the geometry is obtained. In prior work, the geometry is typically intrinsic to the data type: observations such as rotations, orientations, or directions are manifold-valued from the outset. Physiological waveforms, by contrast, are ordinary Euclidean vectors in their raw sample-space representation. The cylindrical structure emerges only after the analytic representation separates each waveform into instantaneous phase and amplitude. We then define the paired source-to-target probability path and its associated vector field on this induced manifold.\n\nHowever, the proposed construction is not merely a reparameterization of Euclidean interpolation. A reparameterization would provide a different coordinate description of the same path. Here, the path itself changes. In both our method and the Hilbert naive baseline, phase trajectories are unwrapped and therefore carry arbitrary additive offsets of $2\\pi k$ determined by their respective unwrapping branches. Linear interpolation between two unwrapped phases depends on these offsets: changing the branch of either endpoint changes every intermediate state. By contrast, the geodesic on $S^1$ is invariant to the branch choice and follows the minimum angular displacement between the endpoints. The two methods therefore define different trajectories between the same signals rather than different coordinate descriptions of a common trajectory.\n\nOur fidelity theorem formalizes this distinction. For endpoints with equal amplitude, the cylindrical path preserves the amplitude exactly and advances the phase at the target angular increment, whereas the affine path produces a strictly nonconstant amplitude whenever the phase increment is nonzero. Because flow matching regresses the velocity of the chosen probability path, changing the path changes both the oracle vector field and the dynamics that the network must learn, even when the architecture and training objective are held fixed. The formulation also extends beyond the choice of interpolant: the vector field is parameterized intrinsically, with the network predicting phase and amplitude velocities that are mapped to a tangent vector on the cylinder, while the circular component is reprojected to unit norm after each solver substep. Moreover, the geodesic produces a constant-norm oracle field, giving the regression target a uniform scale along the bridge. The Hilbert naive baseline isolates the effect of this geometry, and its SCG performance is worse than that of the untranslated source reference. Thus, when the same phase–amplitude representation is retained but the cylindrical geometry is removed, translation can perform worse than applying no translation at all. We will therefore position the method as a geometry-aware formulation of conditional flow matching for quasiperiodic signals: neither a new generative learning paradigm nor a merely notational reparameterization of an existing path."+ },+ "createdAt": "2026-07-28T04:23:02.364Z",+ "modifiedAt": "2026-11-18T17:14:19.688Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=bcZ8yQahsm",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/oeynfrhqtu.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/oeynfrhqtu.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "oeyNFrHQtU",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair xCMN",+ "content": {+ "metareview": "## (a) Scientific Claims/Findings\n\nThe paper introduces a cylindrical geodesic flow matching framework for paired physiological signal translation (e.g., from PPG to SCG). The core claim is that standard affine interpolation in Euclidean space distorts the phase and amplitude of quasiperiodic signals. To resolve this, the authors use the Hilbert transform to decouple signals into phase and amplitude, embedding them onto a cylindrical manifold where flow matching is supervised via geodesic interpolation, preserving the signal's underlying geometric structure.\n\n## (b) Strengths\n\n* [wsWG, Riia, 48Xr, Cpyw] Well-motivated and mathematically elegant formulation. Framing quasiperiodic physiological signals on a cylindrical manifold is an intuitive inductive bias that addresses phase wrapping and amplitude positivity.\n* [wsWG, Riia, Cpyw] Clean experimental setup and execution that achieves consistent empirical improvements over standard affine flow matching and direct regression on the tested translation tasks.\n\n## (c) Weaknesses\n\n* [wsWG, Riia, 48Xr] Limited dataset scope and lack of clinical evaluation. Datasets are small and sourced from a single institution. Crucially, the evaluations rely entirely on waveform similarity metrics without demonstrating downstream clinical utility (e.g., proving that important physiological markers or disease features are accurately preserved).\n* [48Xr, Cpyw] Baselines. The experiments primarily compare against affine interpolation and direct regression, omitting modern, state-of-the-art time-series generative models or advanced alignment-based baselines.\n* [Riia, 48Xr] Justification of the representation and assumptions. Reviewers question whether the performance gains stem fundamentally from the proposed generative formulation or merely from the Hilbert transform preprocessing/alignment. Additionally, the core assumption that phase and amplitude are strictly separable may not hold in real-world, noisy physiological data where sensor effects couple them.\n\n## (d) Recommendations\n\nPlease address the weaknesses above and from the reviewers during the rebuttal."+ },+ "createdAt": "2026-07-21T20:57:00.888Z",+ "modifiedAt": "2026-11-18T15:20:54.597Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=oeyNFrHQtU",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/psa6euzudc.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/psa6euzudc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "pSa6EuZudc",+ "replyTo": "WyUabEAfgi",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "### We thank the reviewer for the careful reading and for pointing us toward the literature on shape analysis. We address each comment below.\n\n### 1. Background on the Hilbert transform\n\nWe agree that the Hilbert transform should be introduced more thoroughly because it is central to our formulation. We will further elaborate on the standard and Extended Hilbert transforms in the supplementary material, including their derivations, implementation details, and step-by-step procedures.\n\n### 2. Center effects, suitability across modalities, and remaining errors\n\nThe center-cropping limitation arises because the discrete Fourier transform treats a finite signal window as periodic, which can distort the analytic signal near its boundaries. We reduce this effect by applying the transform to a window larger than the segment used by the model and retaining only its center. For PPG, the transform is applied to 4096 samples, while the model uses the center 2048; for SCG, it is applied to 1024 samples, while the model uses the center 512. Thus, the samples most affected by boundary artifacts are excluded from the model input. However, this mitigation requires sufficient signal before and after the segment of interest. It may therefore be less effective for short recordings or segments located near the beginning or end of a recording. We will clarify that center cropping reduces boundary effects in our datasets but is not a general solution for every dataset.\n\nWe will also distinguish structural applicability from demonstrated empirical generalization. Structurally, the framework can be applied to modalities for which a stable and meaningful oscillatory phase and positive amplitude can be extracted. This does not imply that the present experiments establish generalization across all modalities, datasets, or recording conditions.\n\nThe suitability of the Hilbert transform depends on the signal characteristics. They are most reliable for signals with a dominant quasiperiodic component and become less reliable for broadband, multicomponent, or noisy signals. PPG, filtered to $[1,4]$ Hz, is closer to the favorable narrowband setting. SCG, filtered to $[2,39]$ Hz, is substantially more broadband and contains multiple morphological components, making its phase more difficult to estimate. For this reason, we evaluate the proposed geometry using both the Hilbert transform and the Extended Hilbert transform. The Extended Hilbert transform directly targets these failure cases and limits residual jumps in phase velocity. Nevertheless, robust phase estimation for broadband physiological signals remains an open research question.\n\nWe identify two related sources of error. First, phase estimation remains imperfect for broadband and multicomponent signals. Second, interference among signal components can produce low-amplitude regions in which the analytic phase becomes poorly conditioned and small perturbations cause large phase changes, even with the Extended Hilbert transform. We will make these sources of error more explicit in the Discussion.\n\n### 3. Baselines and shape analysis for time series\n\nWe agree that the current comparisons do not constitute an exhaustive benchmark of the representations for time series that define the current state of the art. They were selected as controlled ablations under a shared backbone and training protocol. Direct supervised prediction removes the probability path entirely, leaving one endpoint residual per pair; affine flow matching restores the path but keeps the raw waveform as the state, so the bridge is the standard Euclidean path; Hilbert naive flow matching adopts the phase–amplitude coordinates but treats them as Euclidean, with unwrapped phase, linear interpolation; and our method adds the cylindrical representation, geodesic bridge, and intrinsic tangent vector field. We will clarify that these experiments are intended to isolate the contribution of the proposed geometry rather than establish superiority over all generative methods for time series.\n\nWe also appreciate the reference to “Shape Analysis for Time Series.” This family of methods provides a nonlinear representation by describing a time series as a deformation of a learned reference and is therefore closely related to the geometric motivation of our work. However, it addresses unsupervised representation and comparison of individual time series rather than paired conditional generation between physiological modalities. Adapting it to our task would require an additional mapping from the deformation parameters on the source side to the paired target waveform, making it a separately designed pipeline rather than a direct replacement for our probability path.\n\nWe note that this literature already informs our design and is cited in the background, including the treatment of amplitude and phase as distinct sources of variation, multiresolution warping of phase, and Fisher–Rao registration, the last of which our limitations name as the alternative geometry we have not yet explored. We will cite Germain et al. (NeurIPS 2024) explicitly and position it in that discussion."+ },+ "createdAt": "2026-07-28T04:23:47.253Z",+ "modifiedAt": "2026-11-18T17:14:22.812Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=pSa6EuZudc",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/qsanawipja.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/qsanawipja.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "QSanAWiPJa",+ "replyTo": "BBICqXBrrr",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "### We thank the reviewer for the constructive questions. We address each below.\n\n### 1. Do the improvements hold for most subjects?\n\nThis is an important point, and we agree that averages alone can hide subject-level variability. Our evaluation over four random seeds assesses sensitivity to initialization and data partitioning.\n\nWe have computed the per-subject, per-seed breakdown for both datasets, scoring each evaluation by the model with the lowest mean error. On PPG, the four held-out splits cover 11 distinct test subjects and 20 subject–seed evaluations, giving 60 comparisons across the three metrics under each transform. The cylindrical geodesic path is best in 52 of the 60 comparisons under the standard Hilbert transform (16/20 on DTW, 18/20 on $L_2$, 18/20 on HT distance) and in 51 of the 60 under the Extended Hilbert transform (17/20 on DTW, 16/20 on $L_2$, 18/20 on HT distance). On SCG under limited-support adaptation, the four splits cover 7 distinct test subjects and 12 subject–seed evaluations, giving 36 comparisons per transform, and the cylindrical geodesic path is best in 33 of the 36 under the standard Hilbert transform (11/12 on DTW, 11/12 on $L_2$, 11/12 on HT distance) and in 34 of the 36 under the Extended Hilbert transform (12/12 on DTW, 11/12 on $L_2$, 11/12 on HT distance). Our model is therefore the most frequent winner for both datasets.\n\nIn the revision we will report this in the appendix, so that the consistency of the improvement across subjects can be judged directly rather than only from the average.\n\n### 2. Clinically meaningful features\n\nWe agree that waveform similarity metrics alone do not establish preservation of clinically meaningful information. We were unfortunately not able to complete this evaluation within the rebuttal period, as reliable fiducial annotation requires careful manual review of a large number of waveforms and the time available was not sufficient. We are committed to including it in the revision.\n\nConcretely, we will manually annotate the pulse foot in the ground truth and reconstructed PPG waveforms and report its absolute timing error. We will also annotate the untranslated source waveforms, quantifying the landmark offset between source and target that the translation must correct and providing the same source reference comparison used in the main results.\n\nWe considered using automated PPG and SCG fiducial detectors, but this would combine reconstruction error with detector error, particularly for noisy SCG landmarks such as aortic opening and closure. Manual annotation provides a more direct evaluation, although a larger annotation study with independent clinical experts remains necessary.\n\n### 3. Other devices, institutions, and populations\n\nOn devices and populations we already have partial evidence. The PPG cohort comprises 20 subjects and 11,483 windows, while the SCG cohort comprises 13 subjects across 24 sessions and 30,494 beats. The two cohorts differ in device and modality, and the recordings from exercise recovery/resistive breathing introduce meaningful cardiovascular variation and variation related to motion, so the improvement reported above is not specific to a single sensor or signal type.\n\nWe nevertheless agree that the limited cohort size and data collection at a single institution restrict the generalizability of the findings. These recordings do not represent the full range of conditions encountered in deployment, and external validation on a larger cohort drawn from multiple institutions is not possible with the present data. We will strengthen this limitation. Stronger motion artifacts, distortions that depend on the sensor, and phase–amplitude coupling should therefore be evaluated in future work using datasets that are larger, noisier, and span more devices and institutions.\n\n### 4. Which part contributes most\n\nThe current baselines were selected exactly as such an ablation, under a shared backbone and training protocol. Direct supervised prediction removes the probability path entirely, leaving one endpoint residual per pair; affine flow matching restores the path but keeps the raw waveform as the state, so the bridge is the standard Euclidean path; Hilbert naive flow matching adopts the phase–amplitude coordinates but treats them as Euclidean, with unwrapped phase, linear interpolation; and our method adds the cylindrical representation, geodesic bridge, and intrinsic tangent vector field. The comparison with Hilbert naive flow matching shows that the Hilbert representation alone is insufficient, while the improvement over affine flow matching shows that the benefit is not explained by flow matching alone; the gain is therefore associated with the geometry used to construct the probability path and vector field. We will discuss this ablation structure more clearly in the revision.\n\n### 5. Failure cases\n\nYes, and we identify two related sources of error. First, phase estimation remains imperfect for broadband and multicomponent signals: PPG, filtered to $[1,4]$ Hz, is closer to the favorable narrowband setting, whereas SCG, filtered to $[2,39]$ Hz, is substantially more broadband and contains multiple morphological components, making its phase more difficult to estimate. Second, interference among signal components can produce low-amplitude regions in which the analytic phase becomes poorly conditioned and small perturbations cause large phase changes, even with the Extended Hilbert transform. The Extended Hilbert transform directly targets these failure cases and limits residual jumps in phase velocity, but robust phase estimation for broadband physiological signals remains an open research question. We will make these sources of error more explicit in the Discussion."+ },+ "createdAt": "2026-07-28T04:18:42.979Z",+ "modifiedAt": "2026-11-18T17:14:43.312Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=QSanAWiPJa",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/qsftwromc6.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/qsftwromc6.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "qSFtwroMC6",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "## (a) Scientific Claims/Findings\n\nThe paper introduces a cylindrical geodesic flow matching framework for paired physiological signal translation (e.g., from PPG to SCG). The core claim is that standard affine interpolation in Euclidean space distorts the phase and amplitude of quasiperiodic signals. To resolve this, the authors use the Hilbert transform to decouple signals into phase and amplitude, embedding them onto a cylindrical manifold where flow matching is supervised via geodesic interpolation, preserving the signal's underlying geometric structure.\n\n## (b) Strengths\n\n* [wsWG, Riia, 48Xr, Cpyw] Well-motivated and mathematically elegant formulation. Framing quasiperiodic physiological signals on a cylindrical manifold is an intuitive inductive bias that addresses phase wrapping and amplitude positivity.\n* [wsWG, Riia, Cpyw] Clean experimental setup and execution that achieves consistent empirical improvements over standard affine flow matching and direct regression on the tested translation tasks.\n\n## (c) Weaknesses\n\n* [wsWG, Riia, 48Xr] Limited dataset scope and lack of clinical evaluation. Datasets are small and sourced from a single institution. Crucially, the evaluations rely entirely on waveform similarity metrics without demonstrating downstream clinical utility (e.g., proving that important physiological markers or disease features are accurately preserved).\n* [48Xr, Cpyw] Baselines. The experiments primarily compare against affine interpolation and direct regression, omitting modern, state-of-the-art time-series generative models or advanced alignment-based baselines.\n* [Riia, 48Xr] Justification of the representation and assumptions. Reviewers question whether the performance gains stem fundamentally from the proposed generative formulation or merely from the Hilbert transform preprocessing/alignment. Additionally, the core assumption that phase and amplitude are strictly separable may not hold in real-world, noisy physiological data where sensor effects couple them.\n\n## (d) Recommendations\n\nPlease address the weaknesses above and from the reviewers during the rebuttal.",+ "final_justification": "This paper reports an interesting approach for paired physiological signal translation via cylindrical geodesic flow matching. Reviewers have agreed that the technical methodology is interesting and well ablated. During the rebuttal, the reviewers were able to address existing concerns on dataset scope, baselines, and justification of the representation and other assumptions. The remaining concern from 48Xr focuses on the weaker healthcare validation, while acknowledging that the method is technically interesting. I believe that this is fine for a NeurIPS venue in which the primary contributions are focused on ML methodologies, especially with the lack of public datasets to do this extra validation. However, I do ask the authors make this clear in the limitations of their final camera ready version."+ },+ "createdAt": "2026-09-24T11:20:00.693Z",+ "modifiedAt": "2026-11-18T14:54:38.458Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=qSFtwroMC6",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/rk8dehskmy.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/rk8dehskmy.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "Rk8DEHskMY",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Riia",+ "content": {+ "summary": "This paper proposes a geometry-aware flow matching framework for paired physiological signal translation. Instead of using the standard linear interpolation in flow matching, the authors represent each signal in a phase-amplitude space using the Hilbert transform and model the interpolation as a geodesic on a cylindrical manifold. They evaluate the method on two signal translation tasks (sternum-to-finger PPG and clavicle-to-sternum SCG) and compare it with direct supervised learning and conventional flow matching. Their method achieves lower waveform reconstruction errors, suggesting that respecting the intrinsic geometry of oscillatory signals leads to better translation performance.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strength\n1. Clear motivation. The idea of incorporating the phase and amplitude is technically sound.\n2. The proposed geodesic bridge is elegant.\n3. Clean experiment setup. \n\nWeakness\n1. Only evaluates the waveform reconstruction quality. However, the motivation is to enable downstream clinical analysis with the translated signal. There are no convincing results that such a translation provides better analysis than directly training a new model.\n2. The cylindrical manifold is constructed based on the Hilbert phase-amplitude representation, which is only one possible way to represent oscillatory signals. Although this choice is intuitive, it would strengthen the paper to provide further discussion or empirical evidence explaining why this representation best captures the intrinsic geometry of the data.\n3. Experiments limited to only two signal translation tasks.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "1. In real clinical applications, how sensitive is the proposed method to temporal misalignment or sampling differences between the source and target signals?\n2. The motivation for signal translation is to leverage existing clinical analysis pipelines. However, if signals from the non-standard sensing locations are easy to acquire at scale, would it be more practical to directly train downstream models on those signals rather than introducing an intermediate translation step?\n3. The paper states that the theoretical framework is agnostic to the choice of analytic signal transform (170), while the experiments only evaluate the Hilbert Transform and Extended Hilbert Transform. Have the authors explored other analytic signal representations (e.g., wavelet- or EMD-based approaches), and if so, how do the results compare?",+ "limitations": "Yes.",+ "rating": 5,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The rebuttal addressed my main concerns, particularly by clarifying the synchronization procedure, the motivation for translation rather than direct downstream training, and the scope of the analytic signal representation. These explanations strengthened the justification for the proposed framework. Therefore, I maintain my Accept score."+ },+ "createdAt": "2026-06-26T04:20:37.594Z",+ "modifiedAt": "2026-11-18T13:38:48.692Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=Rk8DEHskMY",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/uafc6x9b1h.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/uafc6x9b1h.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "UAFC6X9b1H",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer 48Xr",+ "content": {+ "summary": "This paper proposes a cylindrical geodesic flow matching framework for paired physiological signal translation (e.g., PPG and SCG). The method decomposes signals into instantaneous phase and amplitude via analytic signal transforms, embeds them into a cylindrical manifold S^1 \\times \\mathbb{R}^+, and replaces standard affine interpolation in flow matching with geodesic interpolation on this manifold. The resulting oracle velocity field is used to train a conditional flow model. Experiments on PPG and SCG translation tasks show improvements over affine interpolation and direct regression baselines under both zero-shot and limited-support settings.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths:\nThe paper addresses an interesting and practically relevant problem in physiological signal translation, where phase wrapping and amplitude positivity are known challenges for standard Euclidean interpolation. The idea of explicitly separating phase and amplitude and constructing a geometry-aware interpolation path is well motivated from a signal processing perspective. The proposed cylindrical representation is mathematically clean, and the resulting geodesic formulation provides a structured alternative to affine paths used in conditional flow matching. Experimental results show consistent improvements across multiple metrics and datasets.\n\nWeaknesses:\n1. The central claim that cylindrical representation improves flow matching relies on separating phase and amplitude, but it is not clearly demonstrated that this decoupling is essential. The improvement may stem from better alignment induced by preprocessing rather than a fundamentally improved generative formulation.\n2. The model assumes a product manifold structure S^1 \\times \\mathbb{R}^+, but in real physiological signals, phase and amplitude are often coupled through sensor effects, motion artifacts, and physiological variability. This raises questions about whether the geometric assumption is valid beyond idealized settings.\n3. The comparison is mainly against affine interpolation, Hilbert-based baselines, and direct regression. Stronger modern time-series generative or alignment-based methods are not included, making it unclear whether the gains persist under stronger competitors.\n4. The PPG dataset (20 subjects) and SCG dataset (13 subjects) are relatively small. It is also unclear whether the subjects include pathological conditions. If not, the task may not reflect clinically meaningful waveform translation but rather smooth interpolation between similar signals.\n5. The main methodological change is replacing Euclidean interpolation with geodesic interpolation under cylindrical coordinates. While this improves structure, it is not clear whether this constitutes a fundamentally new learning framework or a geometry-aware reparameterization of existing conditional flow matching.",+ "quality": 3,+ "clarity": 3,+ "significance": 2,+ "originality": 3,+ "questions": "As noted in the Weaknesses.",+ "limitations": "The paper appropriately notes some limitations, such as sensitivity to low-amplitude phase instability and limited evaluation scope. However, additional limitations include the reliance on a strong phase–amplitude separability assumption, small dataset size, and unclear clinical diversity of the evaluation cohorts. These factors may limit the generality of the conclusions beyond controlled experimental settings.",+ "rating": 3,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "NA",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The rebuttal addresses several of my previous concerns, particularly by clarifying the motivation of source-to-canonical-site translation and providing additional downstream validation through pulse foot timing analysis. These additions improve my confidence that the proposed method captures more than waveform-level similarity.\nHowever, the remaining concern is the scope of healthcare validation. The current evidence is still based on small, single-institution healthy cohorts and focuses on limited physiological measurements. It remains unclear whether the learned translation generalizes to pathological conditions or provides broader clinical utility beyond signal reconstruction.\nOverall, I find the method technically interesting, but the current evidence mainly supports a physiological signal translation framework rather than a fully validated healthcare application. I maintain my borderline reject recommendation."+ },+ "createdAt": "2026-06-24T04:58:23.494Z",+ "modifiedAt": "2026-11-18T13:38:49.836Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=UAFC6X9b1H",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/wsyokqi1wk.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/wsyokqi1wk.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "WSyokqI1wK",+ "replyTo": "Rk8DEHskMY",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "### We thank the reviewer for these questions. We address each below.\n\n### 1. Sensitivity to temporal misalignment and sampling differences\n\nThe method is sensitive to temporal misalignment, so we do not rely on device timestamps because the devices operate on independent clocks. Instead, we synchronize the streams using the ECG recorded simultaneously by both devices. We first estimate a session-level offset by cross-correlating RR-interval tachograms interpolated onto a common 4 Hz grid. We then refine the alignment to sample resolution through matched filtering of the bandpass-filtered ECG in 300-second windows with a 20-second stride and window-level outlier rejection. These time-varying estimates compensate for clock drift over the approximately 30-minute recordings, which cannot be corrected by a single fixed offset. After synchronization, all channels are resampled to 500 Hz, and ECG R-peaks define the cardiac-cycle anchors used to segment the SCG.\n\nWe will clarify that this procedure corrects only the offset and drift between device clocks. Physiological timing differences between the source and target sensing locations are preserved and must be learned by the translation model. This distinction also motivates reporting both $L_2$ and DTW. $L_2$ penalizes timing and morphological differences jointly, whereas DTW is more tolerant of local temporal shifts.\n\n### 2. Translation versus direct downstream training on the source signal\n\nWe agree that direct downstream training is the better choice when a sufficiently large, task-labeled dataset is already available at the non-standard sensing location. Our motivation concerns the opposite regime. Source signals may be easy to acquire, while task-specific labels, reference measurements, and validated analysis pipelines remain tied to the target site, where the clinical reference standard is defined or most reliably expressed. Scalable acquisition therefore does not make direct training scalable. Each downstream task requires its own labeled source-site dataset, often involving expert annotation or an additional clinical reference measurement, and each combination of sensing location, device, and task requires separate validation. A translation model is instead trained from simultaneously recorded source- and target-site signals and then provides a common interface to established target-site analyses, such as aortic opening and closing times, pre-ejection period, and vascular or oximetric biomarkers, with an inspectable intermediate output that helps localize downstream errors. We will clarify that translation is not inherently preferable to direct downstream training and cannot recover information absent from the source signal. Its value is greatest when source signals are abundant but task-specific labels are scarce, and when several validated canonical-site pipelines must be supported.\n\n\n### 3. Other analytic signal representations\n\nWe have not evaluated wavelet- or EMD-based representations, and we will state this scope rather than leave the claim of transform agnosticism unqualified.\n\nOur geometry requires a transform that assigns each time sample a single phase on $S^1$ and a single positive amplitude, and that pairs these coordinates consistently between source and target. HT and EHT satisfy this by construction, since the analytic signal is defined pointwise and uniquely. Wavelet- and EMD-based methods also yield instantaneous phase and amplitude, but not in this form. A continuous wavelet transform returns a time-scale distribution, so a per-sample phase depends on an added ridge or scale selection rule and on the mother wavelet. EMD requires selecting one of several intrinsic mode functions, and because the decomposition is data-dependent and subject to mode mixing, the selected mode need not correspond to the same physiological component in the source and the target of a pair. Since our probability path transports phase between them, an inconsistent correspondence would corrupt the supervision directly.\n\nBoth families therefore require a component selection and pairing rule, which changes the method rather than instantiating it, so they are not drop-in replacements for the analytical signal, $\\mathcal{A}$. We will revise the statement to say that the theory is agnostic to any transform yielding a single dominant analytic component per sample, that HT and EHT are the instantiations we evaluate, and that multicomponent representations fall outside the scope of the present formulation."+ },+ "createdAt": "2026-07-28T04:22:06.540Z",+ "modifiedAt": "2026-11-18T17:14:41.213Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=WSyokqI1wK",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/wyuabeafgi.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/wyuabeafgi.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "WyUabEAfgi",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Cpyw",+ "content": {+ "summary": "The paper aims to generate quasi-periodic physiological waveforms, such as photoplethysmography (PPG) signals, recorded at one body location using signals acquired from another location. This conditional sampling problem can be reformulated as a flow-matching problem. A key aspect of flow matching lies in the choice of prior injected into the interpolant. While previous work typically relies on affine interpolants, these are not well suited to quasi-periodic signals. The authors instead propose applying the Hilbert transform to the waveform to extract its amplitude and phase, and then modeling these features on a cylindrical manifold using the corresponding geodesic interpolant within the flow-matching framework. Theoretical results demonstrate that the approach is well grounded and properly motivated, while experiments on two clinical datasets highlight the practical relevance and effectiveness of the method.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "**Strengths:**\n\n- The paper achieves a good balance between theoretical development and practical relevance. \n- The proposed idea is meaningful and has the potential to generalize to other datasets. \n- The presentation is clear, with enough detail to follow the methodology without becoming overwhelming. \n- The discussion is honest, and the limitations are clearly acknowledged. \n\n**Weaknesses:**\n\n- While I am familiar with flow matching and geometric methods, I was not previously familiar with the Hilbert transform, which plays a central role in this work. I would therefore recommend introducing it more thoroughly in the background section. \n- In the limitations, you note that generalization to other datasets may be challenging due to center effects, yet you appear relatively optimistic about the applicability across data types. Could you elaborate on how suitable the Hilbert transform is expected to be for multimodal quasi-periodic signals? Additionally, it would be helpful to clarify what you consider to be the main remaining sources of error in your experiments. \n- Although I am not an expert in this specific application domain, the baseline methods appear somewhat simplistic and do not fully leverage state-of-the-art representations for flow matching. For instance, approaches such as those proposed in *“Shape Analysis for Time Series”* might provide a more informative comparison.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "Can you address my previous questions ?",+ "limitations": "The limitations are clearly discussed.",+ "rating": 5,+ "confidence": 2,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No concern",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "I recommend acceptance of this paper because the proposed method is both theoretically and experimentally well motivated. While additional experiments on larger datasets and comparisons with a broader range of baselines would further strengthen the empirical evidence supporting the method, the authors clearly acknowledge and discuss these limitations. Overall, the proposed idea is interesting, relevant, and worthy of being shared with the research community."+ },+ "createdAt": "2026-06-23T07:11:16.148Z",+ "modifiedAt": "2026-11-18T13:38:51.470Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=WyUabEAfgi",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/submission.json added
+++ b/reviews/openreview/1nmpaqewkp/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "1NmpaqEwkP",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 12782,+ "url": "https://openreview.net/forum?id=1NmpaqEwkP",+ "license": "CC-BY-4.0"+}
versions/v_cgqeti8u.json added
+++ b/versions/v_cgqeti8u.json@@ -0,0 +1,22 @@+{+ "date": "2026-05-01",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 12782,+ "url": "https://openreview.net/forum?id=1NmpaqEwkP",+ "reviews": "openreview/1nmpaqewkp",+ "evidence": [+ "https://openreview.net/forum?id=1NmpaqEwkP"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=1NmpaqEwkP",+ "evidence": [+ "https://openreview.net/forum?id=1NmpaqEwkP"+ ]+}