Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation
Update NeurIPS 2026 submission 1NmpaqEwkP: 10 notes
@openreview[bot] · 2026-11-24 15:44 UTC · 8e56800194d2 ·
reviews/openreview/1nmpaqewkp/notes/1zguoqmwun.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/1zguoqmwun.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "1ZGuOQMwun",+ "replyTo": "3tcEIGMe0T",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "We thank the reviewer for this acknowledgment and will incorporate the vector space approach as an alternative perspective in our Discussion.",+ "comment": "We thank the reviewer for this thoughtful follow-up and agree that the flexibility and ease of implementation of vector space approaches are important practical considerations. We will add this perspective to the Discussion as an alternative representation based approach. Additionally, we appreciate the reviewer’s practical perspective in recognizing that a direct empirical comparison would require a separately designed pipeline and may be beyond the scope of the current work."+ },+ "createdAt": "2026-08-02T16:01:15.776Z",+ "modifiedAt": "2026-11-19T17:20:04.582Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=1ZGuOQMwun",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/3tceigme0t.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/3tceigme0t.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "3tcEIGMe0T",+ "replyTo": "pSa6EuZudc",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer Cpyw",+ "content": {+ "title": "Thank you for your answer.",+ "comment": "Thank you for the clarification.\n\nRegarding Point 3, I acknowledge that the proposed method is not specifically designed for flow matching. However, a practitioner could still represent the data using an appropriate embedding or representation method and subsequently apply a standard flow-matching approach designed for vector spaces. While this may introduce an additional processing step, it could simplify implementation when dealing with heterogeneous modalities and data formats. From a practical perspective, this raises the question of whether the benefits of a dedicated metric-space approach outweigh the flexibility and ease of implementation offered by existing vanilla vector-space methods.\n\nThat said, I acknowledge that conducting such a comparison would likely require substantial additional work and could be beyond the current scope of the paper."+ },+ "createdAt": "2026-07-29T06:51:31.385Z",+ "modifiedAt": "2026-11-19T17:20:04.814Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=3tcEIGMe0T",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/h9emasrg9q.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/h9emasrg9q.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "H9EMAsRG9Q",+ "replyTo": "vk0nZeJlpK",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "We thank the reviewer for the follow-up. We address the remaining points below and hope that these clarifications resolve the reviewer’s concerns.",+ "comment": "### 1. Necessity of the cylindrical geometry\n\nThe cylindrical geometry follows from our chosen representation rather than being imposed afterward. We represent instantaneous phase on $S^1$ and positive amplitude on $\\mathbb{R}_{>0}$. The embedding is isometric (Theorem 1), making the product metric $m=d\\phi^2+da^2$ its pullback, and the resulting cylindrical path minimizes length under this metric (Theorem 3).\n\nThe circular treatment of phase is central. Because phase is defined modulo $2\\pi$, Euclidean interpolation between unwrapped phases depends on an arbitrary branch and can assign unbounded errors to phase excursions where the amplitude is low and the phase unreliable. The bounded embedding $(\\cos\\phi,\\sin\\phi)$ is invariant to the branch, crosses the wrap point continuously, and follows the minimum angular displacement. The Hilbert naive baseline isolates this choice by using the same phase and amplitude representation but treating phase as Euclidean; it performs worse on PPG and falls below the untranslated source on SCG.\n\nThe cylindrical path also preserves amplitude for endpoints of equal amplitude and yields an oracle field of constant norm, providing a uniformly scaled regression target (Theorem 2 and Proposition 1). These properties remain under any positive weighting $\\lambda\\, d\\phi^2 + \\mu\\, da^2$. We therefore claim necessity with respect to preserving these structural properties, not that the cylinder is the only possible manifold aware formulation. The amplitude coordinate remains a modeling choice, as already noted in our limitations.\n\n### 2. Other representations and formulations\n\nWe agree that alternatives are possible, including general Riemannian flow matching, elastic and diffeomorphic shape representations, and multicomponent decompositions such as EMD, VMD, wavelet ridges, and synchrosqueezing. These methods could induce toroidal or other formulations on product manifolds.\n\nHowever, they are not direct replacements for the single analytic component used here. Wavelet methods produce time scale representations, while EMD and VMD produce multiple components. A trajectory of phase and amplitude therefore requires an additional component or ridge selection rule and, for paired translation, a correspondence ensuring that the selected components represent the same physiological process in both signals. Mode mixing, decompositions that depend on the data, and inconsistent component ordering make this correspondence nontrivial. An incorrect pairing would directly alter the supervised probability path.\n\nThese alternatives are promising extensions, but they require additional choices for component selection, source-target pairing, and path construction. We therefore focus here on establishing the cylindrical formulation for a single analytic component and will clarify this scope.\n\n### 3. Generality of the inductive bias\n\nWe agree that the empirical benefit has been demonstrated only on the two datasets studied here. Theorems 1–3 and Proposition 1 are independent of the dataset and require only a nonvanishing analytic representation. However, this theory alone does not establish empirical generalization across institutions, devices, populations, or modalities.\n\nWithin the evaluated cohorts, the gains are consistent rather than driven by a few subjects. Across subjects, seeds, and metrics, the cylindrical path is best in 52 of 60 PPG and 33 of 36 SCG comparisons using the standard Hilbert transform, and in 51 of 60 and 34 of 36 comparisons using the Extended Hilbert transform. This supports consistency within the evaluated cohorts but not broader external generalization. \n\nThe representation may also become unreliable for signals that are strongly multicomponent, noisy, or locally low in amplitude. We will therefore clarify that our contribution begins once a meaningful single analytic component is available, and that larger, externally collected, and more diverse datasets are needed to establish broader empirical generality."+ },+ "createdAt": "2026-07-30T19:54:00.720Z",+ "modifiedAt": "2026-11-19T17:20:04.719Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=H9EMAsRG9Q",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/ifleysxl8a.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/ifleysxl8a.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "ifleYsxL8a",+ "replyTo": "s0ZuyFyLbj",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Thank you for the follow-up. We address the remaining points, with additional experiments on PPG pulse foot timing.",+ "comment": "We thank the reviewer for noting that the technical concerns raised in the initial review, the distinction between changing the probability path and reparameterizing the representation, and the role of the phase–amplitude representation isolated by the Hilbert naive baseline, are now better addressed. We address the three remaining points below.\n\n### 1. Why recovering a canonical-site waveform is necessary\n\nWe agree, and will state this motivation explicitly in the revision. Direct downstream training is the better choice when a large labeled dataset for the task is already available at the convenient sensing location. Our motivation concerns the opposite regime. Source signals may be easy to acquire, while labels, reference measurements, and validated analysis pipelines remain tied to the target site, where the clinical reference standard is defined or most reliably expressed. Scalable acquisition therefore does not make direct training scalable. Each downstream task requires its own labeled dataset at the source site, and each combination of sensing location, device, and task requires separate validation. A translation model is instead trained once from simultaneously recorded source and target signals and then provides a common interface to established analyses at the target site, such as aortic opening and closing times, pre-ejection period, and vascular biomarkers. Translation is not inherently preferable and cannot recover information absent from the source signal. Its value is greatest when source signals are abundant but labels are scarce, and when several validated pipelines at canonical sites must be supported.\n\n### 2. Does the model learn physiology or sensor morphology?\n\nLearning how the same cardiac events appear at two locations is the task itself. The question is whether the mapping is conditioned on the source or reproduces a fixed template at the target site. Three observations support the former. (i) SCG source and target use the same sensor type on two patches, so the difference is placement rather than device, and the mapping cannot reduce to a device transfer function. (ii) The protocols drive large changes in heart rate, respiratory effort, and hemodynamics within a session, so the output must track the source as state changes. For SCG, adaptation uses only an early session prefix, while evaluation covers later stress and recovery states unseen during adaptation. (iii) Gains are distributed across test subjects, covering 52 of 60 (PPG) and 33 of 36 (SCG) waveform comparisons. These observations argue against simple target template reproduction and indicate that the learned mapping is conditioned on source specific variation across subjects and physiological states.\n\n### 3. Public datasets and downstream validation\n\n**Downstream validation.** Waveform similarity alone does not establish preservation of clinically meaningful information. Therefore, during the discussion period, we conducted a new downstream analysis by detecting the PPG pulse foot with NeuroKit2, applying one unchanged detector to the target, each reconstruction, and the untranslated source, and measuring absolute timing error against the reference device. All translation methods reduce the source error. Translation lowers pulse foot timing error from 28.30 ms to 18.48 ms with the cylindrical geodesic, which is best in 51 of 60 evaluations across subjects and seeds. Relative to the strongest translation baseline, the additional improvement is smaller (3.20 ms), but consistent across evaluations.\n\n| Model | MAE vs. Biopac PPG (ms, mean ± SD) |\n| ----------------- | ---------------------------------: |\n| Source | 28.30 ± 13.42 |\n| Supervised | 21.86 ± 13.71 |\n| TS Affine | 21.68 ± 12.74 |\n| Hilbert Naive | 21.82 ± 14.14 |\n| **Cyl. Geodesic** | **18.48 ± 13.24** |\n\nPulse foot timing anchors pulse arrival and transit time, quantities of order 100–300 ms underlying estimation of cuffless blood pressure and arterial stiffness.\n\n**Public datasets.** Our focus is translation between locations within one modality. Reconstruction across modalities differs, since biomarkers in the target modality may be absent from the source. MIMIC contains PPG, ECG, and AP, but no paired recordings of one modality at several sites, so it cannot evaluate the problem of sensor placement. We are not aware of a public dataset that provides the synchronized same modality, multi location recordings under physiological perturbations required to evaluate the sensor placement translation setting studied here.\n\nWe omit automated SCG aortic opening and closure, since detector error may be comparable to the effect measured. Cohorts from one institution limit external validity. Studies with expert annotation on diverse external cohorts remain necessary to establish clinical utility."+ },+ "createdAt": "2026-08-01T05:43:02.095Z",+ "modifiedAt": "2026-11-19T17:20:04.722Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=ifleYsxL8a",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/mwamam8q2i.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/mwamam8q2i.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "MwaMAM8Q2i",+ "replyTo": "pVH0P0T5dG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "We thank the reviewer for the follow-up and the positive assessment, and we clarify that synchronization is needed only for training, not at inference.",+ "comment": "We thank the reviewer for the careful reading, for the follow-up, and for maintaining the positive assessment. The temporal misalignment and sampling difference procedure is used only to construct paired training data and for any limited-support adaptation to a new device pair and it is not needed for inference. We should have stated this explicitly.\n\nThe problem this procedure solves is purely one of independent hardware clocks. Two devices, even two units of the same model, do not sample at exactly the same effective rate once they are started and deployed on the participant. Streams nominally sampled at 500 Hz may run at, for example, 499.5 or 500.5 samples per second on average. Over a roughly 45 minute session, this produces accumulating drift. This is why we use a physiological reference observed by both devices (the ECG R-peak series) to establish their correspondence and estimate a time varying lag that corrects for subsequent clock drift.\n\nThis synchronization is required only when signals from two independent devices with independent clocks must be brought into correspondence, that is, when constructing paired training data and, likewise, for any limited-support adaptation to a new device pair. At inference, the model receives only the source waveform and ECG conditioning, which are collected on the same device clock and share a single sample index. No target signal and no cross device synchronization are involved. The only preprocessing required is the within device processing already described: bandpass filtering, resampling that device's channels onto the 500 Hz grid, and, for the SCG task, R-peak detection on its own ECG to define the cardiac cycle anchors used for segmentation. We will revise the preprocessing description in the paper to state this separation explicitly."+ },+ "createdAt": "2026-08-02T16:43:53.055Z",+ "modifiedAt": "2026-11-19T17:20:04.529Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=MwaMAM8Q2i",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/oeynfrhqtu.json modified
+++ b/reviews/openreview/1nmpaqewkp/notes/oeynfrhqtu.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair xCMN","content": {- "metareview": "## (a) Scientific Claims/Findings\n\nThe paper introduces a cylindrical geodesic flow matching framework for paired physiological signal translation (e.g., from PPG to SCG). The core claim is that standard affine interpolation in Euclidean space distorts the phase and amplitude of quasiperiodic signals. To resolve this, the authors use the Hilbert transform to decouple signals into phase and amplitude, embedding them onto a cylindrical manifold where flow matching is supervised via geodesic interpolation, preserving the signal's underlying geometric structure.\n\n## (b) Strengths\n\n* [wsWG, Riia, 48Xr, Cpyw] Well-motivated and mathematically elegant formulation. Framing quasiperiodic physiological signals on a cylindrical manifold is an intuitive inductive bias that addresses phase wrapping and amplitude positivity.\n* [wsWG, Riia, Cpyw] Clean experimental setup and execution that achieves consistent empirical improvements over standard affine flow matching and direct regression on the tested translation tasks.\n\n## (c) Weaknesses\n\n* [wsWG, Riia, 48Xr] Limited dataset scope and lack of clinical evaluation. Datasets are small and sourced from a single institution. Crucially, the evaluations rely entirely on waveform similarity metrics without demonstrating downstream clinical utility (e.g., proving that important physiological markers or disease features are accurately preserved).\n* [48Xr, Cpyw] Baselines. The experiments primarily compare against affine interpolation and direct regression, omitting modern, state-of-the-art time-series generative models or advanced alignment-based baselines.\n* [Riia, 48Xr] Justification of the representation and assumptions. Reviewers question whether the performance gains stem fundamentally from the proposed generative formulation or merely from the Hilbert transform preprocessing/alignment. Additionally, the core assumption that phase and amplitude are strictly separable may not hold in real-world, noisy physiological data where sensor effects couple them.\n\n## (d) Recommendations\n\nPlease address the weaknesses above and from the reviewers during the rebuttal."+ "metareview": "## (a) Scientific Claims/Findings\n\nThe paper introduces a cylindrical geodesic flow matching framework for paired physiological signal translation (e.g., from PPG to SCG). The core claim is that standard affine interpolation in Euclidean space distorts the phase and amplitude of quasiperiodic signals. To resolve this, the authors use the Hilbert transform to decouple signals into phase and amplitude, embedding them onto a cylindrical manifold where flow matching is supervised via geodesic interpolation, preserving the signal's underlying geometric structure.\n\n## (b) Strengths\n\n* [wsWG, Riia, 48Xr, Cpyw] Well-motivated and mathematically elegant formulation. Framing quasiperiodic physiological signals on a cylindrical manifold is an intuitive inductive bias that addresses phase wrapping and amplitude positivity.\n* [wsWG, Riia, Cpyw] Clean experimental setup and execution that achieves consistent empirical improvements over standard affine flow matching and direct regression on the tested translation tasks.\n\n## (c) Weaknesses\n\n* [wsWG, Riia, 48Xr] Limited dataset scope and lack of clinical evaluation. Datasets are small and sourced from a single institution. Crucially, the evaluations rely entirely on waveform similarity metrics without demonstrating downstream clinical utility (e.g., proving that important physiological markers or disease features are accurately preserved).\n* [48Xr, Cpyw] Baselines. The experiments primarily compare against affine interpolation and direct regression, omitting modern, state-of-the-art time-series generative models or advanced alignment-based baselines.\n* [Riia, 48Xr] Justification of the representation and assumptions. Reviewers question whether the performance gains stem fundamentally from the proposed generative formulation or merely from the Hilbert transform preprocessing/alignment. Additionally, the core assumption that phase and amplitude are strictly separable may not hold in real-world, noisy physiological data where sensor effects couple them.\n\n## (d) Recommendations\n\nPlease address the weaknesses above and from the reviewers during the rebuttal.",+ "final_justification": "This paper reports an interesting approach for paired physiological signal translation via cylindrical geodesic flow matching. Reviewers have agreed that the technical methodology is interesting and well ablated. During the rebuttal, the reviewers were able to address existing concerns on dataset scope, baselines, and justification of the representation and other assumptions. The remaining concern from 48Xr focuses on the weaker healthcare validation, while acknowledging that the method is technically interesting. I believe that this is fine for a NeurIPS venue in which the primary contributions are focused on ML methodologies, especially with the lack of public datasets to do this extra validation. However, I do ask the authors make this clear in the limitations of their final camera ready version."},"createdAt": "2026-07-21T20:57:00.888Z",- "modifiedAt": "2026-11-18T15:20:54.597Z",+ "modifiedAt": "2026-11-19T05:00:33.967Z","url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=oeyNFrHQtU","license": "CC-BY-4.0"}
reviews/openreview/1nmpaqewkp/notes/pvh0p0t5dg.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/pvh0p0t5dg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "pVH0P0T5dG",+ "replyTo": "WSyokqI1wK",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer Riia",+ "content": {+ "comment": "Thank you for the detailed response. The rebuttal has satisfactorily addressed most of my concerns. However, from my understanding of Section 1 “Sensitivity to Temporal Misalignment and Sampling Differences”, the proposed synchronization procedure appears to require paired source and target signals to estimate the clock offset and sampling differences. Could the authors clarify how synchronization would be performed during inference when paired target signals are unavailable? Overall, I find this to be an interesting piece of work, and I will therefore keep my Accept score."+ },+ "createdAt": "2026-08-02T08:39:10.819Z",+ "modifiedAt": "2026-11-19T17:20:04.557Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=pVH0P0T5dG",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/s0zuyfylbj.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/s0zuyfylbj.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "s0ZuyFyLbj",+ "replyTo": "H9EMAsRG9Q",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 48Xr",+ "content": {+ "title": "Remaining Concerns on Clinical Utility and Generalizability",+ "comment": "The rebuttal has clarified several technical concerns regarding the proposed cylindrical geometry. In particular, the distinction between changing the flow path and merely reparameterizing the representation is better justified, and the Hilbert-naive baseline provides useful evidence that the gain is related to the proposed geometric formulation rather than phase–amplitude representation alone.\n\nHowever, my main remaining concern is the alignment between the proposed task and the healthcare impact expected for this track. The paper motivates waveform translation as a solution to sensor placement variability in wearable cardiovascular monitoring. While differences between sensing locations (e.g., wrist vs. finger PPG or different SCG placements) are real, the paper does not sufficiently establish why recovering a canonical-site waveform is clinically necessary or more valuable than directly learning clinically relevant biomarkers from the convenient sensing location.\n\nMore importantly, the current task setting uses synchronized source and target recordings from the same subjects and cardiac events. Therefore, the model mainly learns a mapping between different sensor observations of the same physiological rhythm. This is an interesting signal translation problem, but it remains unclear whether the learned transformation captures clinically meaningful physiological information or mainly learns normal sensor-dependent waveform morphology. This concern is amplified by the fact that the evaluation is conducted on small, single-institution healthy cohorts.\n\nFor a healthcare-oriented contribution, stronger validation on clinically meaningful settings would be important. For example, evaluating whether translated waveforms preserve downstream diagnostic performance or physiological measurements would provide more direct evidence of practical value. Public clinical waveform datasets with paired signals (e.g., MIMIC waveform data) could potentially enable evaluation of whether translated signals approach the utility of real clinical measurements for tasks such as diagnosis or biomarker estimation.\nOverall, I find the technical contribution interesting as a geometry-aware physiological signal translation method. However, the current evidence mainly supports a signal modeling contribution, while the healthcare significance and clinical utility of the proposed translation remain insufficiently validated. Therefore, I maintain my borderline reject recommendation."+ },+ "createdAt": "2026-08-01T02:11:09.898Z",+ "modifiedAt": "2026-11-19T17:20:04.683Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=s0ZuyFyLbj",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/vk0nzejlpk.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/vk0nzejlpk.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "vk0nZeJlpK",+ "replyTo": "bcZ8yQahsm",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 48Xr",+ "content": {+ "title": "Remaining Concerns: Scope of Experimental Validation",+ "comment": "The rebuttal satisfactorily addressed most of my concerns regarding preprocessing, the geometric formulation, and the role of the cylindrical representation. Although the rebuttal clarifies that the contribution is intended as a geometry-aware formulation rather than a new generative paradigm, I remain uncertain about the necessity of the proposed cylindrical geometry. The current experiments convincingly demonstrate improvements over affine flow matching, but do not yet establish whether comparable gains could be achieved by other periodic signal representations or manifold-aware formulations. In addition, the evaluation remains limited to relatively small in-house datasets, leaving the generality of the proposed inductive bias insufficiently validated."+ },+ "createdAt": "2026-07-30T08:06:17.371Z",+ "modifiedAt": "2026-11-19T17:20:04.808Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=vk0nZeJlpK",+ "license": "CC-BY-4.0"+}
reviews/openreview/1nmpaqewkp/notes/yf7yk8kjh7.json added
+++ b/reviews/openreview/1nmpaqewkp/notes/yf7yk8kjh7.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "yf7Yk8kjH7",+ "replyTo": "QSanAWiPJa",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Update on clinically meaningful features, with additional experiments on PPG pulse foot timing.",+ "comment": "We would like to update our response to question 2.\n\nWe agree that waveform similarity alone does not establish preservation of clinically meaningful information. While we still believe that expert annotation would provide the most complete assessment of clinical relevance, we wanted to investigate whether clinically meaningful timing information is also preserved using an established automated detection pipeline. During the discussion period, we detected the PPG pulse foot with NeuroKit2, applying one unchanged detector to the target, each reconstruction, and the untranslated source, and measured absolute timing error against the reference device. All translation methods reduce the source error. Translation lowers pulse foot timing error from 28.30 ms to 18.48 ms with the cylindrical geodesic, which is best in 51 of 60 evaluations across subjects and seeds, so the improvement can again be judged across subjects rather than only from the average. Relative to the strongest translation baseline, the additional improvement is smaller (3.20 ms), but consistent across evaluations.\n\n| Model | MAE vs. Biopac PPG (ms, mean ± SD) |\n| ----------------- | ---------------------------------: |\n| Source | 28.30 ± 13.42 |\n| Supervised | 21.86 ± 13.71 |\n| TS Affine | 21.68 ± 12.74 |\n| Hilbert Naive | 21.82 ± 14.14 |\n| **Cyl. Geodesic** | **18.48 ± 13.24** |\n\nPulse foot timing anchors pulse arrival and transit time, quantities of order 100–300 ms underlying estimation of cuffless blood pressure and arterial stiffness.\n\nIn our experiments, the NeuroKit2 PPG pulse foot detector was robust enough to locate the fiducial reliably, and because one unchanged detector is applied to the target, each reconstruction, and the untranslated source, its residual error enters every row in the same way and the comparison across methods remains informative. We report only the PPG task because the available SCG fiducial detectors were not sufficiently reliable, and their detection error may be comparable to the differences between reconstruction methods, potentially confounding the comparison. Studies with expert annotation on diverse external cohorts, as described in our earlier response, remain necessary to establish clinical utility more completely. Nevertheless, these results are important because automated fiducial-detection pipelines are already widely used in the physiological signal processing literature, where continuous manual annotation is infeasible. Therefore, the results show that the improvement in waveform reconstruction translates to improved preservation of a clinically relevant timing feature."+ },+ "createdAt": "2026-08-04T02:40:49.199Z",+ "modifiedAt": "2026-11-19T17:20:04.583Z",+ "url": "https://openreview.net/forum?id=1NmpaqEwkP¬eId=yf7Yk8kjH7",+ "license": "CC-BY-4.0"+}