potentialpaper

CycleSpectra: Cyclic Motion Spectra for Phase-Queryable 4D Cardiac Reconstruction

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:41 UTC · 8d42888b0f58 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,27 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "R6WdWujy5S"
- }
- ],
- "title": "CycleSpectra: Cyclic Motion Spectra for Phase-Queryable 4D Cardiac Reconstruction",
- "authors": [
- "Xueming Fu",
- "Xin Li",
- "Lixia Han",
- "Ao Shen",
- "Guangming Lu",
- "Song Luo",
- "S Kevin Zhou"
- ],
- "abstract": "Reconstructing patient-specific cyclic cardiac motion at arbitrary phases is central to dynamic cardiac assessment, underpinning measurements such as ejection fraction, stroke volume, and regional myocardial deformation. Existing methods—pair-wise registration, time-conditioned decoders, and coordinate-based implicit fields—share a common implicit assumption: the cardiac cycle is treated as a sequence of discrete phases, with temporal structure assembled through learned mappings supervised at the observed frames. Yet the cycle is a closed periodic process. We propose CycleSpectra, a spectral motion representation that takes the cyclic structure as a starting point of the representation rather than as a property to be learned. Given a pair of sparsely sampled phase observations, the model learns the spectral structure of the underlying cyclic cardiac motion in a low-dimensional latent space, and recovers the displacement at any phase through a fixed analytic synthesis layer—time never enters the network as a learnable signal, only as a coordinate the readout takes by construction. To support evaluation, we collect a thin-slice phase-resolved 4D cardiac CT cohort and benchmark under both canonical and non-canonical input protocols, reporting whole-cycle motion-fidelity metrics alongside standard image and anatomical metrics. Under arbitrary two-frame input, CycleSpectra attains the lowest mean left-ventricular ejection-fraction error and the highest mean ventricular volume–time curve correlation among recent baselines, while remaining competitive on image fidelity. Beyond two-frame inference, the proposed framework supports test-time multi-frame latent fusion for higher accuracy, validated on both the in-house cohort and a cross-modality 4D cardiac MR cohort. Code is available at https://github.com/windrise/CycleSpectra.",
- "year": 2026,
- "venue": "NeurIPS 2026",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "a1927962-273c-4aca-a8e6-c9c55fc73f1f"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,17 @@
+{
+ "title": "CycleSpectra: Cyclic Motion Spectra for Phase-Queryable 4D Cardiac Reconstruction",
+ "authors": [
+ "Xueming Fu",
+ "Xin Li",
+ "Lixia Han",
+ "Ao Shen",
+ "Guangming Lu",
+ "Song Luo",
+ "S Kevin Zhou"
+ ],
+ "abstract": "Reconstructing patient-specific cyclic cardiac motion at arbitrary phases is central to dynamic cardiac assessment, underpinning measurements such as ejection fraction, stroke volume, and regional myocardial deformation. Existing methods—pair-wise registration, time-conditioned decoders, and coordinate-based implicit fields—share a common implicit assumption: the cardiac cycle is treated as a sequence of discrete phases, with temporal structure assembled through learned mappings supervised at the observed frames. Yet the cycle is a closed periodic process. We propose CycleSpectra, a spectral motion representation that takes the cyclic structure as a starting point of the representation rather than as a property to be learned. Given a pair of sparsely sampled phase observations, the model learns the spectral structure of the underlying cyclic cardiac motion in a low-dimensional latent space, and recovers the displacement at any phase through a fixed analytic synthesis layer—time never enters the network as a learnable signal, only as a coordinate the readout takes by construction. To support evaluation, we collect a thin-slice phase-resolved 4D cardiac CT cohort and benchmark under both canonical and non-canonical input protocols, reporting whole-cycle motion-fidelity metrics alongside standard image and anatomical metrics. Under arbitrary two-frame input, CycleSpectra attains the lowest mean left-ventricular ejection-fraction error and the highest mean ventricular volume–time curve correlation among recent baselines, while remaining competitive on image fidelity. Beyond two-frame inference, the proposed framework supports test-time multi-frame latent fusion for higher accuracy, validated on both the in-house cohort and a cross-modality 4D cardiac MR cohort. Code is available at https://github.com/windrise/CycleSpectra.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}