CycleSpectra: Cyclic Motion Spectra for Phase-Queryable 4D Cardiac Reconstruction
Update NeurIPS 2026 submission R6WdWujy5S: 7 notes
@openreview[bot] · 2026-11-24 15:50 UTC · 93557ca07005 ·
reviews/openreview/r6wdwujy5s/notes/ctsjztckfp.json modified
+++ b/reviews/openreview/r6wdwujy5s/notes/ctsjztckfp.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair cQ44","content": {- "metareview": "The reviewers appreciate its strong performance on global clinical metrics such as LVEF and volume-time curves, but express valid concerns regarding external verifiability due to the small, private CT dataset (36 subjects) and the lack of local myocardial deformation evaluation (e.g., strain or local displacement). To move toward a solid acceptance, the authors must clarify baseline fairness, provide local motion fidelity evaluations, and offer per-subject confidence intervals for the small test set."+ "metareview": "The reviewers appreciate its strong performance on global clinical metrics such as LVEF and volume-time curves, but express valid concerns regarding external verifiability due to the small, private CT dataset (36 subjects) and the lack of local myocardial deformation evaluation (e.g., strain or local displacement). To move toward a solid acceptance, the authors must clarify baseline fairness, provide local motion fidelity evaluations, and offer per-subject confidence intervals for the small test set.",+ "final_justification": "Having carefully read the authors' rebuttal, the revised experimental results, and the post-rebuttal reviewer discussions, I recommend acceptance.\n\nFollowing the discussion period, reviewer sentiment is unanimously positive (scores: 5, 5, 4), with Reviewer uXDb raising their rating to 4. All reviewers agreed that the rebuttal satisfactorily resolved their primary technical and empirical concerns.\n\nBut do carefully check the citations before camera-ready:\n\nList of Problematic References with Reasoning\n@inproceedings{shao2023neural,\n author = {Xiaoxiao Shao and Shanlin Sun and Kun Yang and Wenhao Tang and Zhennan Yan and Dimitris Metaxas and Pingkun Yan},\n title = {Neural deformable models for 3D bi-ventricular heart shape reconstruction and modeling from 2D sparse cardiac magnetic resonance imaging},\n booktitle = {Proceedings of the IEEE/CVF International Conference on Computer Vision (ICCV)},\n year = {2023}\n}\nAlthough the paper title exists and was published at ICCV 2023, the author list in the provided BibTeX citation is almost entirely incorrect. The actual authors of the paper are Meng Ye, Dong Yang, Mikael Kanski, Leon Axel, and Dimitris Metaxas, whereas the citation lists incorrect authors such as Xiaoxiao Shao, Shanlin Sun, Kun Yang, Wenhao Tang, Zhennan Yan, and Pingkun Yan."},"createdAt": "2026-07-16T14:47:16.623Z",- "modifiedAt": "2026-11-18T15:21:12.574Z",+ "modifiedAt": "2026-11-19T05:00:43.347Z","url": "https://openreview.net/forum?id=R6WdWujy5S¬eId=CTsJZtckFP","license": "CC-BY-4.0"}
reviews/openreview/r6wdwujy5s/notes/fcfnpqh3o4.json added
+++ b/reviews/openreview/r6wdwujy5s/notes/fcfnpqh3o4.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "FCFNpQh3o4",+ "replyTo": "CTsJZtckFP",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Summary for Area Chair",+ "comment": "We thank the AC and reviewers. The meta-review raises external verifiability of the small private cohort and the lack of local motion evaluation, and asks us to clarify baseline fairness, provide local motion fidelity, and offer per-subject confidence intervals. We address all below, after a brief restatement of the contribution.\n\n**Core contribution**\n\nCycleSpectra reformulates full-cycle cardiac motion reconstruction as sparse anchor/context phase-querying.\n\n- **Fits heterogeneous clinical data.** It handles subjects with missing phases and different sampling rates, instead of assuming a fixed, dense frame grid.\n- **Not tied to ED/ES.** It reconstructs the full cycle from an arbitrary two-frame input and stays accurate off the ED/ES extrema, where interpolation baselines collapse.\n- **Amortized and scalable.** A learned cohort-level prior maps sparse frames to a per-site Fourier motion spectrum; the same model accepts a variable number of input frames (supplementary), and the phase-query readout avoids the memory cost of dense frames at once.\n- **Gain from learning a shared, enforced-periodic spectrum, not the Fourier basis.** In a matched ablation changing only the motion representation, a sinusoidal phase-conditioned decoder keeps image fidelity but collapses motion fidelity (LVEF 8.00→19.69; curve correlation 0.862→0.718).\n\n**Baseline fairness**\n\nAll methods receive identical inference-time information and evaluation: the same two CT volumes (64×128×128), the same query phases, no access to query ground truth, and the same reference masks, metrics, and frame→pair→subject aggregation on the same 7 subjects. We did not impose our sparse anchor/context recipe on the baselines; each keeps its native training paradigm and is evaluated in its strongest form. The only differences between methods are phase representation, training exposure, and objective—what the comparison should measure.\n\nTo avoid any unfairness from prediction-side masks (which follow each method's native output), we add a common frozen-nnU-Net output-side control applied to all methods; it yields the same ranking.\n\n**Local motion fidelity**\n\nWe add a local evaluation under a single frozen nnU-Net shared by all methods, on the opposite-pair protocol (85 pairs, 7 subjects), from two angles: (i) deformation regularity (Jacobian/folding, flow magnitude), and (ii) per-chamber Dice/HD95. Regional strain cannot be measured on this cohort: it has no tagged MRI, landmarks, or dense deformation ground truth. Across all seven methods, CycleSpectra has the best cardiac-5 macro-average Dice and is best on every structure except the right atrium (edged out by 0.004). The Jacobian comparison shows substantial, near-incompressible, fold-free myocardial motion. Full tables are in the muhU response.\n\n**Per-subject confidence intervals**\n\nWe reduce measurements frame→pair→subject, then subjects→cohort, and report 95% CIs from 10,000 subject-level bootstrap resamples. Full tables are in the 1SoJ response.\n\n**On external verifiability**\n\nTo make the pipeline externally verifiable, we will release the training/inference/evaluation code, the frozen evaluation protocol, the evaluator, and the subject-level bootstrap scripts. We state the small-cohort limitation explicitly and narrow generalization claims to the evidence.\n\n**Summary**\n\nAcross all reviews, we: showed through a matched ablation that the gain comes from the learned sparse-to-spectral mapping rather than the Fourier basis; established baseline fairness via matched inference and evaluation plus a shared output-side control; added local motion-fidelity evaluation (per-chamber overlap and deformation regularity); reported per-subject confidence intervals for the small test set; clarified the context-phase mechanism and the curve-correlation protocol; and will release the code and evaluation scripts."+ },+ "createdAt": "2026-07-29T06:31:36.683Z",+ "modifiedAt": "2026-11-19T17:03:34.264Z",+ "url": "https://openreview.net/forum?id=R6WdWujy5S¬eId=FCFNpQh3o4",+ "license": "CC-BY-4.0"+}
reviews/openreview/r6wdwujy5s/notes/kulwbvoj9h.json added
+++ b/reviews/openreview/r6wdwujy5s/notes/kulwbvoj9h.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "KUlWBvOj9h",+ "replyTo": "q5sHYcvwmJ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 1SoJ",+ "content": {+ "comment": "Thank you for the clarification and for recomputing the affected results with the corrected evaluator. The revised reporting, common-nnU-Net comparison, and more cautious interpretation address my remaining concerns. I maintain my positive assessment and score."+ },+ "createdAt": "2026-08-03T03:38:13.768Z",+ "modifiedAt": "2026-11-19T17:03:34.161Z",+ "url": "https://openreview.net/forum?id=R6WdWujy5S¬eId=KUlWBvOj9h",+ "license": "CC-BY-4.0"+}
reviews/openreview/r6wdwujy5s/notes/m3assqfyyr.json added
+++ b/reviews/openreview/r6wdwujy5s/notes/m3assqfyyr.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "M3AsSqfYYR",+ "replyTo": "mrEbbtQGeb",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 1SoJ",+ "content": {+ "comment": "Thank you for the careful response. The provenance clarification, common-segmenter control, subject-level bootstrap, sparse-supervision experiment, and abnormal-contraction failure case address my main concerns.\nPlease reconcile the full-model curve correlations of 0.836 in the new sparse-supervision table, 0.871 in the submission, and the corrected 0.862. Since the bookkeeping error affects curve correlation and SV error, please also confirm that all ablation rows were recomputed; using the same erroneous evaluator for both arms does not by itself guarantee unchanged differences.\nThe common-nnU-Net table should be included in the revision. Where subject-level intervals overlap with strong baselines, please describe CycleSpectra as having the best nominal mean unless paired intervals for method differences establish superiority. Finally, the 23.13-to-20.91 dB decrease under sparse supervision is meaningful and should not be characterized as a small image-fidelity change. Subject to these corrections, I maintain my positive assessment."+ },+ "createdAt": "2026-08-01T05:57:01.214Z",+ "modifiedAt": "2026-11-19T17:03:34.216Z",+ "url": "https://openreview.net/forum?id=R6WdWujy5S¬eId=M3AsSqfYYR",+ "license": "CC-BY-4.0"+}
reviews/openreview/r6wdwujy5s/notes/pt3q93b53s.json added
+++ b/reviews/openreview/r6wdwujy5s/notes/pt3q93b53s.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Pt3Q93b53s",+ "replyTo": "k66L4N0DFZ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer muhU",+ "content": {+ "title": "Response to author rebuttal",+ "comment": "Thank you for the detailed response and clarifying the phase-encoding control, baseline fairness, additional local-motion proxy analyses. I appreciate the authors’ honest discussion of the low-LVEF failure case. I would keep my positive assessment."+ },+ "createdAt": "2026-08-03T11:38:19.637Z",+ "modifiedAt": "2026-11-19T17:03:34.132Z",+ "url": "https://openreview.net/forum?id=R6WdWujy5S¬eId=Pt3Q93b53s",+ "license": "CC-BY-4.0"+}
reviews/openreview/r6wdwujy5s/notes/q5shycvwmj.json added
+++ b/reviews/openreview/r6wdwujy5s/notes/q5shycvwmj.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "q5sHYcvwmJ",+ "replyTo": "M3AsSqfYYR",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the careful follow-up. We agree with these corrections.\nTo reconcile the three full-model curve correlations: 0.871 was the submitted direct mean over 85 opposite pairs computed from the legacy records containing duplicated LV-volume entries; 0.836 used the same legacy records but applied frame-to-pair-to-subject-to-cohort aggregation; and 0.862 uses the corrected LV records with that same subject-balanced aggregation. We will retain only 0.862 as the full-model opposite-pair result in the revision.\n\nWe also agree that using the same erroneous evaluator for both ablation arms did not guarantee unchanged differences; our previous statement was too strong. We have now reloaded the frozen checkpoints and fully recomputed all affected representation, Fourier-order, loss-design, and sparse-supervision rows with the corrected evaluator on the same 85 opposite pairs and seven subjects, rather than re-aggregating the legacy JSON. The central conclusions remain unchanged: the corrected spectral K=4 model achieves a curve correlation of 0.862 versus 0.718 for the matched non-periodic decoder, while strict ED+ES+one-mid supervision decreases it from 0.862 to 0.432. The complete corrected tables, including the newly audited SV results, will be included in the revision.\n\nWe will also include the common-nnU-Net table in the revision. Where subject-level intervals overlap with strong baselines, we will describe CycleSpectra as having the best nominal mean unless a paired method-difference interval establishes superiority. Finally, we agree that the 23.134-to-20.912 dB decrease under sparse supervision is meaningful, and we will replace our previous “changes little” characterization accordingly.\nThank you again for prompting these corrections."+ },+ "createdAt": "2026-08-01T15:41:17.055Z",+ "modifiedAt": "2026-11-19T17:03:34.214Z",+ "url": "https://openreview.net/forum?id=R6WdWujy5S¬eId=q5sHYcvwmJ",+ "license": "CC-BY-4.0"+}
reviews/openreview/r6wdwujy5s/notes/tou2juilzq.json added
+++ b/reviews/openreview/r6wdwujy5s/notes/tou2juilzq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "tOu2juiLzq",+ "replyTo": "gcmg9J5uaw",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you again for taking the time to review our paper. As the Reviewer–Author Discussion period is nearing its end, we would greatly appreciate it if you could let us know whether our responses have adequately addressed your concerns. Any further feedback would be very helpful to us!"+ },+ "createdAt": "2026-08-03T03:24:06.091Z",+ "modifiedAt": "2026-11-19T17:03:34.194Z",+ "url": "https://openreview.net/forum?id=R6WdWujy5S¬eId=tOu2juiLzq",+ "license": "CC-BY-4.0"+}