potentialpaper

EGCA: A Spectral Perspective on Forward Process Design in Diffusion Models

Update NeurIPS 2026 submission Xb3MCNndt3: 10 notes

@openreview[bot] · 2026-11-24 15:52 UTC · 209fb65e1017 ·

Evidence

reviews/openreview/xb3mcnndt3/notes/0m6bz7qppo.json added

+++ b/reviews/openreview/xb3mcnndt3/notes/0m6bz7qppo.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "0M6bz7qPPo",
+ "replyTo": "MF7RoCbzrm",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to the Official Comment by Reviewer isWo",
+ "comment": "Thank you for the follow-up and for maintaining your positive rating. We appreciate that the eigenvalue correction and the clarification of the role of $\\lambda_1$ address your main concerns. We have completed the following corrected and controlled analyses. \n\n- **Corrected matched-$\\lambda_1$ comparison.**\n\nWe corrected the eigenvalue inconsistency in Table 2. For each dataset, the two generators below have the same drift and $\\lambda_1=1$, but differ in their diffusion coefficients.\n\n| Dataset | $a$ | $b$ | $\\lambda_1$ | $T_{\\mathrm{conv}}$ | FID $\\downarrow$ | $T_{\\mathrm{spend}}$ $\\downarrow$ |\n|---|---:|---:|---:|---:|---:|---:|\n| CIFAR-10 | $1/2$ | $-x$ | 1.00 | 825 | 3.15 | 35 h |\n| CIFAR-10 | $1$ | $-x$ | 1.00 | 825 | 3.23 | 34 h |\n| CelebA-HQ-64 | $1/2$ | $-x$ | 1.00 | 800 | 3.34 | 67 h |\n| CelebA-HQ-64 | $1$ | $-x$ | 1.00 | 800 | 3.39 | 67 h |\n\nThe identical $T_{\\mathrm{conv}}$ values are consistent with the matched spectral rate, whereas the small FID differences confirm that $\\lambda_1$ is not a complete predictor of generation quality. This corrected table replaces the original Table 2, and Table 9 has also been corrected accordingly.\n\n- **Stationary-law-controlled comparison.**\n\nWe also compared generators with the same invariant distribution but different spectral rates. In this linear setting, the two generators for each dataset have the same stationary law $N(0,1)$, while $\\lambda_1$ changes from $0.5$ to $1$.\n\n| Dataset | $a$ | $b$ | $\\lambda_1$ | $T_{\\mathrm{conv}}$ | FID $\\downarrow$ | $T_{\\mathrm{spend}}$ $\\downarrow$ |\n|---|---:|---:|---:|---:|---:|---:|\n| CIFAR-10 | $1/2$ | $-0.5x$ | 0.50 | 1000 | 4.44 | 45 h |\n| CIFAR-10 | $1$ | $-x$ | 1.00 | 825 | 3.23 | 34 h |\n| CelebA-HQ-64 | $1/2$ | $-0.5x$ | 0.50 | 1000 | 3.82 | 104 h |\n| CelebA-HQ-64 | $1$ | $-x$ | 1.00 | 800 | 3.39 | 67 h |\n\nThe faster setting reduces both $T_{\\mathrm{conv}}$ and training time while improving FID, showing that the observed difference cannot be attributed solely to the terminal stationary distribution.\n\n- **Clarifying $D_{\\mathrm{disc}}$ as a convergence proxy.**\n\nFor the fixed generator $(a,b)=(1/2,-0.5x)$, we evaluated $D_{\\mathrm{disc}}$, $\\chi^2$, and SWD (sliced Wasserstein distance) at six forward-process steps.\n\n| Distance | $t=300$ | $t=350$ | $t=500$ | $t=750$ | $t=825$ | $t=1000$ |\n|---|---:|---:|---:|---:|---:|---:|\n| $D_{\\mathrm{disc}}$ | 0.261750 | 0.202912 | 0.086225 | 0.034000 | 0.029950 | 0.029888 |\n| $\\chi^2$ | 1.337646 | 0.836184 | 0.123921 | 0.007775 | 0.005414 | 0.005733 |\n| SWD | 1.026133 | 0.714032 | 0.231643 | 0.050635 | 0.040193 | 0.032171 |\n\nTheir pairwise correlations are:\n\n| Metric pair | Pearson $r$ | Spearman $\\rho$ |\n|---|---:|---:|\n| $D_{\\mathrm{disc}}$ and $\\chi^2$ | 0.986843 | 0.942857 |\n| $D_{\\mathrm{disc}}$ and SWD | 0.998106 | 1.000000 |\n| $\\chi^2$ and SWD | 0.994396 | 0.942857 |\n\nThese results show that $D_{\\mathrm{disc}}$ closely tracks both $\\chi^2$ and SWD over the evaluated trajectory. Nevertheless, we use $D_{\\mathrm{disc}}$ only as a practical marginal stopping proxy, not as a substitute for a full high-dimensional discrepancy. The correlations are supporting diagnostics for this controlled setting rather than a general equivalence claim.\n\nIn the revision, we will incorporate these corrected and controlled results, explicitly report the terminal variance and log-SNR trajectories, identify the matched quantities in each comparison, clarify the role of $D_{\\mathrm{disc}}$, and explain the training-budget convention."
+ },
+ "createdAt": "2026-08-03T09:55:52.867Z",
+ "modifiedAt": "2026-11-19T16:59:23.955Z",
+ "url": "https://openreview.net/forum?id=Xb3MCNndt3&noteId=0M6bz7qPPo",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xb3mcnndt3/notes/6xrqcybwkr.json added

+++ b/reviews/openreview/xb3mcnndt3/notes/6xrqcybwkr.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "6XRqCybwkr",
+ "replyTo": "M8STkMhmG6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer LaNs",
+ "content": {
+ "comment": "I thank the authors for their response, which has addressed my main concerns. After taking into account the other reviewers' comments, I have raised my score to 4."
+ },
+ "createdAt": "2026-08-03T08:21:30.754Z",
+ "modifiedAt": "2026-11-19T16:59:23.982Z",
+ "url": "https://openreview.net/forum?id=Xb3MCNndt3&noteId=6XRqCybwkr",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xb3mcnndt3/notes/cqpjlww9ji.json modified

+++ b/reviews/openreview/xb3mcnndt3/notes/cqpjlww9ji.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair tcYD",
"content": {
- "metareview": "The paper uses the spectral gap of the forward generator as a coordinate for comparing and selecting diffusion processes. The authors derive exponential convergence bounds governed by the spectral gap, provide a numerical estimator for this quantity, and use it to guide generator selection. Their experiments suggest that a moderate spectral gap may offer a favorable balance between convergence speed and generation fidelity.\n\nThe paper studies an interesting and practically relevant problem. The underlying exponential convergence analysis is largely standard due to the semigroup contraction theory, applying this idea to the design and selection of diffusion forward generators is relatively fresh. However, the reviewers identify several important weaknesses, including inconsistencies in the matched-eigenvalue experiments, the difficulty of separating the benefit of generator design from that of noise-schedule tuning, and the weak EDM and DiT baselines, which make the claims difficult to interpret.\n\nDuring the rebuttal, the authors should address the correctness and consistency of the $\\lambda_1$ calculations and provide stronger evidence that the observed performance gains are specifically attributable to the choice of spectral regime rather than to changes in the schedule, stationary distribution, or other properties of the forward process."
+ "metareview": "The paper uses the spectral gap of the forward generator as a coordinate for comparing and selecting diffusion processes. The authors derive exponential convergence bounds governed by the spectral gap, provide a numerical estimator for this quantity, and use it to guide generator selection. Their experiments suggest that a moderate spectral gap may offer a favorable balance between convergence speed and generation fidelity.\n\nThe paper studies an interesting and practically relevant problem. The underlying exponential convergence analysis is largely standard due to the semigroup contraction theory, applying this idea to the design and selection of diffusion forward generators is relatively fresh. However, the reviewers identify several important weaknesses, including inconsistencies in the matched-eigenvalue experiments, the difficulty of separating the benefit of generator design from that of noise-schedule tuning, and the weak EDM and DiT baselines, which make the claims difficult to interpret.\n\nDuring the rebuttal, the authors should address the correctness and consistency of the $\\lambda_1$ calculations and provide stronger evidence that the observed performance gains are specifically attributable to the choice of spectral regime rather than to changes in the schedule, stationary distribution, or other properties of the forward process.",
+ "final_justification": "The authors did a good job during the rebuttal, resolving concerns about the correctness and consistent treatment of $\\lambda_1$ and providing additional empirical evidence. All reviewers now recommend weak acceptance.\n\nI think this is a borderline paper, it's leans slightly acceptance. I therefore also recommend weak acceptance."
},
"createdAt": "2026-07-20T14:08:08.944Z",
- "modifiedAt": "2026-11-18T15:21:14.473Z",
+ "modifiedAt": "2026-11-19T05:00:45.771Z",
"url": "https://openreview.net/forum?id=Xb3MCNndt3&noteId=CqpJLWw9Ji",
"license": "CC-BY-4.0"
}

reviews/openreview/xb3mcnndt3/notes/ivdj6qgj34.json added

+++ b/reviews/openreview/xb3mcnndt3/notes/ivdj6qgj34.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Ivdj6qgj34",
+ "replyTo": "APhpdkM1jY",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to the Official Comment by Reviewer LaNs",
+ "comment": "Thank you for the follow-up and for reconsidering your assessment. We appreciate that our response addressed your main concerns. Below, we provide further clarification on the compatibility experiments.\n\n- **Fairness and scope of the EDM/EDM2, DiT, and flow-matching-style experiments.**\n\nWe clarify that the original manuscript presents these experiments as row-matched compatibility evaluations rather than as state-of-the-art reproductions. EDM and EDM2 examine alternative training formulations, DiT examines a transformer-based denoising architecture, and the flow-matching-style setting is included as an empirical boundary comparison.\n\nWe agree, however, that the different resource-matching rules were not reported sufficiently explicitly. All comparisons use the same baseline $\\left(\\frac12,-\\frac12x\\right)$ with $T_{\\mathrm{conv}}=1000$ and the EGCA generator $\\left(\\frac12,-x\\right)$ with $T_{\\mathrm{conv}}=825$. However, the resource-matching convention differs by setting.\n\n| Setting | Matching rule | Main controlled factors | Purpose and supported scope |\n|---|---|---|---|\n| EDM/EDM2 | Baseline: 200 epochs; EGCA: $165=200\\times825/1000$ epochs. | CIFAR-10; batch size 32; Heun, 50 steps; same formulation. | Reduced-budget compatibility evidence. |\n| DiT | Baseline: 50 epochs; EGCA: $41=[50\\times825/1000]$ epochs. Four paired training-time checkpoints. | ImageNet-256; batch size 2; DDIM, 250 steps; same architecture. | Architecture-level trajectory evidence. |\n| Flow-matching-style | 300 epochs for both. | CIFAR-10; batch size 32; Heun, 50 steps. | Equal-epoch boundary evidence; outside the current theory. |\n\nThe table makes clear that the three settings do not use a single identical training-budget convention. EDM and EDM2 test efficiency under a $T_{\\mathrm{conv}}$-proportional epoch budget, DiT examines the relative trend over paired training checkpoints, and the flow-matching-style experiment is an equal-epoch boundary comparison.\n\nAccordingly, these results support only controlled within-pair evidence under the specified protocols. They do not constitute comprehensive validation in fully optimized EDM/EDM2, DiT, or flow-matching pipelines.\n\nIn the revision, we will report the protocols separately rather than making a blanket statement that all settings use an identical training-budget convention."
+ },
+ "createdAt": "2026-08-03T10:00:52.175Z",
+ "modifiedAt": "2026-11-19T16:59:23.971Z",
+ "url": "https://openreview.net/forum?id=Xb3MCNndt3&noteId=Ivdj6qgj34",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xb3mcnndt3/notes/kgbalwp4ns.json added

+++ b/reviews/openreview/xb3mcnndt3/notes/kgbalwp4ns.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "KGbaLWp4Ns",
+ "replyTo": "n7adXhJUxx",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer 7DJ7",
+ "content": {
+ "comment": "Thank you for the additional experiments and clarifications. I appreciate the effort made during the discussion period.\n\nThe response addresses my concerns to some extent. Some questions remain regarding whether the observed improvements would persist at later stages of training, as well as the scope of the complementary evaluation for the EDM/EDM2 and DiT comparisons. I encourage the authors to clarify these limitations and reflect them appropriately in the revised manuscript.\n\nOverall, I will maintain my current score."
+ },
+ "createdAt": "2026-08-03T12:41:10.244Z",
+ "modifiedAt": "2026-11-19T16:59:24.641Z",
+ "url": "https://openreview.net/forum?id=Xb3MCNndt3&noteId=KGbaLWp4Ns",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xb3mcnndt3/notes/mf7rocbzrm.json added

+++ b/reviews/openreview/xb3mcnndt3/notes/mf7rocbzrm.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "MF7RoCbzrm",
+ "replyTo": "v80msZV05H",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer isWo",
+ "content": {
+ "comment": "Thank you for the detailed rebuttal. The correction of the eigenvalue inconsistency and clarification of the intended role of $\\lambda_1$ address my main questions. I encourage the authors to include the promised controlled analysis, report the terminal variance and log-SNR trajectories and clearly state which quantities are matched, clarify $D_{\\mathrm{disc}}$ as a marginal convergence proxy, and explain the training-budget convention in the revision. I would like to maintain my positive rating."
+ },
+ "createdAt": "2026-08-01T21:36:50.574Z",
+ "modifiedAt": "2026-11-19T16:59:23.983Z",
+ "url": "https://openreview.net/forum?id=Xb3MCNndt3&noteId=MF7RoCbzrm",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xb3mcnndt3/notes/n7adxhjuxx.json added

+++ b/reviews/openreview/xb3mcnndt3/notes/n7adxhjuxx.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "n7adXhJUxx",
+ "replyTo": "LfsN6gr6Jh",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to the Official Comment by Reviewer 7DJ7",
+ "comment": "Thank you for your valuable feedback. We address your concerns as follows.\n\n\n- **Clarification of the EDM/EDM2, DiT experiments.**\n\nWe agree that the original manuscript did not make the per-setting budget-matching rules, training endpoints, and convergence status sufficiently explicit for Table 4(b).\n\nAll comparisons use the same baseline $\\left(\\frac12,-\\frac12x\\right)$ with $T_{\\mathrm{conv}}^{\\mathrm{base}}=1000$ and the EGCA generator $\\left(\\frac12,-x\\right)$ with $T_{\\mathrm{conv}}^{\\mathrm{EGCA}}=825$. However, the resource-matching convention differs by setting.\n\n| Setting | Dataset | Training budget and endpoint | Batch size | Sampling setup | FID evaluation | Convergence interpretation |\n|---|---|---|---:|---|---|---|\n| EDM/EDM2 | CIFAR-10 | Baseline: 200 epochs; EGCA: $165=200\\times825/1000$ epochs. Both runs reach their prescribed endpoints. | 32 | Heun; 50 steps for both. | 50,000 samples per method. | $T_{\\mathrm{conv}}$-scaled budget; not fully converged. |\n| DiT | ImageNet-256 | Baseline: 50 epochs; EGCA: $41=[50\\times825/1000]$ epochs. Four paired training checkpoints (Table 14). | 2 | DDIM; 250 steps for both. | 50,000 samples per method at four paired checkpoints. | Relative trajectory comparison; full convergence not established. |\n\nFor EDM and EDM2, the epoch budget is intentionally scaled according to $T_{\\mathrm{conv}}^{\\mathrm{EGCA}}/T_{\\mathrm{conv}}^{\\mathrm{base}}=825/1000$. The comparison therefore tests whether EGCA can maintain or improve FID with 17.5% fewer training epochs. The corresponding wall-clock reduction mainly results from the smaller prescribed epoch budget, rather than from a lower cost per optimization update.\n\nFor DiT, the relative FID improvement is observed at all four evaluated training-time checkpoints. However, because the absolute FID remains high and continues to improve, we interpret this only as a relative trend over the evaluated training interval, not as fully converged DiT performance.\n\nThe per-setting protocol information summarized in the table, including the training-budget rule, training endpoint, batch size, sampling setup, and FID sample count, will be added to the revised manuscript.\n\n\n- **Additional evaluation beyond FID.**\n\nThank you for emphasizing the need for complementary evaluation beyond FID. We evaluated three representative spectral regimes on CIFAR-10 using sFID, Inception Score (IS), Precision, and Recall. Each metric is computed using 50,000 generated images under the same evaluation protocol across settings.\n\n| Dataset | $a$ | $b$ | $\\lambda_1$ | $T_{\\mathrm{conv}}$ | FID $\\downarrow$ (SDE solver) | sFID $\\downarrow$ | IS $\\uparrow$ | Precision $\\uparrow$ | Recall $\\uparrow$ | $T_{\\mathrm{spend}}$ $\\downarrow$ |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| CIFAR-10 | $1/2$ | $-0.5x$ | 0.50 | 1000 | 4.44 | 5.12 | 9.1 | 0.64 | 0.59 | 45 h |\n| CIFAR-10 | $1$ | $-x$ | 1.00 | 825 | 3.23 | 4.15 | 9.3 | 0.65 | 0.60 | 34 h |\n| CIFAR-10 | $1/2$ | $-10x$ | 10.00 | 350 | 6.33 | 6.14 | 8.8 | 0.64 | 0.56 | 20 h |\n\nThe complementary metrics show the same qualitative pattern as FID. Relative to the baseline regime, the intermediate regime improves FID, sFID, IS, Precision, and Recall while reducing $T_{\\mathrm{spend}}$ from 45 h to 34 h. In contrast, the aggressive regime further reduces $T_{\\mathrm{conv}}$ and $T_{\\mathrm{spend}}$, but degrades FID, sFID, IS, and Recall.\n\nWithin the evaluated settings, these results reinforce the efficiency--quality trade-off identified in the manuscript: faster forward contraction reduces computational cost, whereas an overly aggressive spectral regime may degrade sample fidelity and coverage. The intermediate regime provides a better efficiency--quality balance in this experiment. We will include this complementary evaluation in the revised manuscript.\n\n- **Additional qualitative analysis.**\n\nWe generated side-by-side CIFAR-10 samples for the same baseline, intermediate, and aggressive regimes evaluated above.\n\nAll three settings produce visually plausible samples, and the differences are relatively subtle in a finite sample grid. This is expected because FID and the complementary metrics capture distribution-level differences over many samples that may not be obvious from visual inspection alone. The intermediate regime maintains strong visual quality while reducing $T_{\\mathrm{conv}}$ and training time, whereas the aggressive regime shows weaker fidelity and coverage in the quantitative metrics.\n\nThis comparison will be included in the revised manuscript."
+ },
+ "createdAt": "2026-08-03T09:47:07.666Z",
+ "modifiedAt": "2026-11-19T16:59:23.970Z",
+ "url": "https://openreview.net/forum?id=Xb3MCNndt3&noteId=n7adXhJUxx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xb3mcnndt3/notes/pgu7rw6825.json added

+++ b/reviews/openreview/xb3mcnndt3/notes/pgu7rw6825.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "pGu7rw6825",
+ "replyTo": "Hrze8mO5Q6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer 7DJ7",
+ "content": {
+ "comment": "Thank you for the detailed response. However, I do not think my main empirical concerns have yet been resolved.\n\nFor the EDM, EDM2, and DiT experiments, I understand that the goal is a within-pair comparison rather than reproducing fully optimized published results. Still, the training budget, convergence status, sampling setup, and evaluation protocol are necessary to assess whether these comparisons are fair. Since these experiments have already been conducted, I would appreciate seeing these details during the discussion period.\n\nI also believe that evaluation beyond FID is important. As the authors acknowledge, FID alone does not fully capture fidelity and coverage, and the current qualitative results do not directly compare the spectral regimes. I understand the need to avoid unverified results, but simply noting this as a limitation would not fully address the concern. A limited but validated complementary evaluation would still be valuable.\n\nThe theoretical contribution is interesting, but the practical benefit supported by experiments is equally important. I therefore respectfully ask the authors to share the relevant settings and any validated additional results during the discussion period."
+ },
+ "createdAt": "2026-07-29T12:23:11.488Z",
+ "modifiedAt": "2026-11-19T16:59:24.689Z",
+ "url": "https://openreview.net/forum?id=Xb3MCNndt3&noteId=pGu7rw6825",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xb3mcnndt3/notes/ufzgjazjgj.json added

+++ b/reviews/openreview/xb3mcnndt3/notes/ufzgjazjgj.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "UFzGJAZjgj",
+ "replyTo": "KGbaLWp4Ns",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to the Follow-up Comment by Reviewer 7DJ7",
+ "comment": "Thank you again for your continued engagement and thoughtful feedback.\n\nFor DiT, the relative improvement is observed at all four evaluated paired checkpoints, although this does not establish persistence through later-stage or fully converged training. We also clarify that the complementary sFID, IS, Precision, Recall, and qualitative evaluations cover the CIFAR-10 spectral-regime study rather than every EDM/EDM2 and DiT setting. We will make these evaluation scopes and limitations explicit in the revision."
+ },
+ "createdAt": "2026-08-04T11:01:50.113Z",
+ "modifiedAt": "2026-11-19T16:59:23.642Z",
+ "url": "https://openreview.net/forum?id=Xb3MCNndt3&noteId=UFzGJAZjgj",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xb3mcnndt3/notes/yfkagk9gy8.json added

+++ b/reviews/openreview/xb3mcnndt3/notes/yfkagk9gy8.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "YFkAgk9gy8",
+ "replyTo": "CqpJLWw9Ji",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Author Response to the Meta Review of Submission 14032 by Area Chair tcYD",
+ "comment": "We thank the Area Chair for the careful synthesis and for identifying the central issues that must be resolved. We agree that the rebuttal should focus on the correctness of the calculations, causal interpretation, and the scope of the compatibility evidence.\n\n### 1. Correction and verification of the matched-$\\lambda_1$ calculations.\n\nWe re-examined the inconsistency in Tables 2 and 9. The generator $(a,b)=(1,-2x)$ is twice $(a,b)=(1/2,-x)$; by Proposition 5, its principal eigenvalue must also be twice as large. Thus, the two rows cannot both have $\\lambda_1=1$, and the tables are incorrect as written.\n\nWe have removed $(1,-2x)$ from both tables and add $(1,-x)$. Under the same protocol, $(1,-x)$ gives 34h / FID 3.23 on CIFAR-10 and 67h / FID 3.39 on CelebA-HQ-64. This supports our Finding 2: matched $\\lambda_1$ gives similar forward-convergence horizons, but not identical FID. Hence, $\\lambda_1$ is a first-order descriptor of convergence, not a complete descriptor of generation quality. \n\nWe analytically recomputed all linear-generator eigenvalues and cross-checked them against the numerical estimator; the corrected Table 2 appears in our response to Reviewer isWo.\n\n### 2. Generator design, schedule tuning, and attribution of the gains.\n\nGenerator design and schedule tuning are related but distinct. With fixed $L$, changing the scalar schedule in $L_t=\\beta(t)L$ changes only $B(t)=\\int_0^t\\beta(s)\\,ds$. Uniform scaling $L^*=cL$ is therefore schedule rescaling, not a separate generator-design advantage. The relevant design axis is non-proportional changes in $(a,b)$, which alter the dynamics and generally cannot be reproduced by a scalar schedule.\n\nWe will add a stationary-law-controlled comparison: $(a,b)=(1/2,-0.5x)$ and $(1,-x)$ share $N(0,1)$ but differ in $\\lambda_1$, $T_{\\mathrm{conv}}$, FID, and $T_{\\mathrm{spend}}$. Thus, the efficiency--quality trade-off can change while the invariant law is fixed; it is not explained solely by the stationary distribution. (The related table is provided in the response to Reviewer isWo.)\nConversely, the corrected matched-$\\lambda_1$ comparisons vary the stationary law and other generator properties at fixed $\\lambda_1$. These controls help separate effects but do not prove that $\\lambda_1$ independently causes FID differences. \n\nWe will make explicit that $\\lambda_1$ characterizes forward contraction and relates to $T_{\\mathrm{conv}}$ within the studied class, but is not a standalone predictor of FID. The additional diagnostics will be presented as partial controls, not as proof that $\\lambda_1$ alone determines generation quality.\n\n### 3. Interpretation of the EDM/EDM2 and DiT comparisons.\n\nTable 4(b) was designed as a within-pair compatibility evaluation rather than as a state-of-the-art reproduction of fully optimized EDM/EDM2 or DiT systems. All comparisons use the same baseline $\\left(\\frac12,-\\frac12x\\right)$ with $T_{\\mathrm{conv}}=1000$ and the EGCA generator $\\left(\\frac12,-x\\right)$ with $T_{\\mathrm{conv}}=825$. However, the resource-matching convention differs by setting.\n\nFor EDM/EDM2 on CIFAR-10, the baseline trains for 200 epochs and EGCA for $165=200\\times825/1000$; both use batch size 32 and Heun sampling (50 steps), and reach their prescribed endpoints. These are $T_{\\mathrm{conv}}$-proportional reduced-budget comparisons (17.5% fewer EGCA epochs), not full-convergence comparisons.\n\nFor DiT on ImageNet-256, Table 14 reports four paired training checkpoints. The baseline is trained for 50 epochs and EGCA for $41=[50\\times825/1000]$ epochs. Both use batch size 2 and DDIM sampling with 250 steps. The relative FID trend is observed across the four evaluated checkpoints, but the continuing improvement and high absolute FID values mean that these results should not be interpreted as fully converged or state-of-the-art DiT performance.\n\nWe therefore clarify that these results provide controlled relative evidence under the reported paired protocols. Complete per-setting training budgets, checkpoint rules, sampling configurations, and evaluation details are provided in our responses to Reviewers 7DJ7 and LaNs.\n\n### Summary of planned revisions.\n\nBased on the reviewer feedback and the additional analyses above, the revision will:\n\n- Replace the inconsistent matched-$\\lambda_1$ comparison and recheck all eigenvalues.\n- Add the stationary-law-controlled analysis, report terminal variance and log-SNR trajectories, and clarify the distinction between generator design and scalar schedule rescaling.\n- Clarify that $D_{\\mathrm{disc}}$ is a marginal convergence proxy, with $\\chi^2$ and SWD comparisons.\n- Specify the training-budget, sampling, and convergence conventions for each compatibility experiment.\n- Clarify and consistently enforce the intended role of $\\lambda_1$ as a convergence-oriented coordinate for forward contraction and $T_{\\mathrm{conv}}$, while avoiding any implication that it alone predicts generation quality."
+ },
+ "createdAt": "2026-08-03T11:50:11.895Z",
+ "modifiedAt": "2026-11-19T16:59:23.860Z",
+ "url": "https://openreview.net/forum?id=Xb3MCNndt3&noteId=YFkAgk9gy8",
+ "license": "CC-BY-4.0"
+}