Update NeurIPS 2026 submission W44dmCYl89: 8 notes
@openreview[bot] · 2026-11-24 15:52 UTC · be46c3ef4b98 ·
reviews/openreview/w44dmcyl89/notes/6j9k7hac56.json modified
+++ b/reviews/openreview/w44dmcyl89/notes/6j9k7hac56.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair SZLB","content": {- "metareview": "ResFusion unifies medical image registration and fusion through implicit-forward diffusion and a timestep-conditioned registration network, T-RNet. The deformation field evolves during denoising, and the registration and fusion modules are jointly optimized. Experiments cover six fusion tasks on four public datasets, with additional segmentation and registration evaluations.\n\nThe recurring strengths are the relevance of the problem, the natural fit between timestep-conditioned registration and progressive diffusion, and the broad empirical evaluation. ResFusion reports strong performance on most fusion metrics, while the segmentation and registration studies provide additional supporting evidence.\n\nIndeed, integration can be a valid contribution, but the distinct contribution is not yet sufficiently isolated. The rebuttal should clarify the novelty relative to source-image-constrained diffusion fusion and diffusion-based registration, and explain what diffusion adds beyond deterministic iterative refinement. The claimed fusion-to-registration effect also needs stronger support or narrower wording. The authors should clarify the use of synthetically generated misalignment and frame the computational cost relative to both diffusion and lightweight joint baselines."+ "metareview": "ResFusion unifies medical image registration and fusion through implicit-forward diffusion and a timestep-conditioned registration network, T-RNet. The deformation field evolves during denoising, and the registration and fusion modules are jointly optimized. Experiments cover six fusion tasks on four public datasets, with additional segmentation and registration evaluations.\n\nThe recurring strengths are the relevance of the problem, the natural fit between timestep-conditioned registration and progressive diffusion, and the broad empirical evaluation. ResFusion reports strong performance on most fusion metrics, while the segmentation and registration studies provide additional supporting evidence.\n\nIndeed, integration can be a valid contribution, but the distinct contribution is not yet sufficiently isolated. The rebuttal should clarify the novelty relative to source-image-constrained diffusion fusion and diffusion-based registration, and explain what diffusion adds beyond deterministic iterative refinement. The claimed fusion-to-registration effect also needs stronger support or narrower wording. The authors should clarify the use of synthetically generated misalignment and frame the computational cost relative to both diffusion and lightweight joint baselines.",+ "final_justification": "ResFusion addresses a practically relevant problem in medical image fusion by jointly considering the lack of fused ground truth and spatial misalignment, using an implicit-forward diffusion formulation together with time-aware registration and joint optimization. The paper is evaluated across multiple fusion tasks, and shows strong overall empirical performance. The main concerns raised in the initial reviews were the degree of methodological novelty, the evidence for fusion-to-registration feedback, generalization beyond synthetic misalignment, and computational cost. During rebuttal, the authors provided additional clarification and experimental evidence addressing these points, including quantitative registration analysis, evaluation on naturally misaligned clinical images, statistical significance analysis, and further discussion of computational trade-offs. The remaining concern was further examined with an additional controlled experiment, after which the reviewer explicitly stated that the concern had been addressed and increased the rating. More broadly, all three reviewers ultimately gave a borderline-accept assessment, with their final justifications indicating that the rebuttal resolved or substantially addressed their concerns."},"createdAt": "2026-07-22T09:43:49.427Z",- "modifiedAt": "2026-11-18T15:21:16.204Z",+ "modifiedAt": "2026-11-19T05:00:46.487Z","url": "https://openreview.net/forum?id=W44dmCYl89¬eId=6J9K7hAc56","license": "CC-BY-4.0"}
reviews/openreview/w44dmcyl89/notes/hal68iyoq3.json added
+++ b/reviews/openreview/w44dmcyl89/notes/hal68iyoq3.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "HAl68IyOq3",+ "replyTo": "6J9K7hAc56",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Clarification of concerns raised in the meta-review",+ "comment": "Dear Area Chair,\n\nWe sincerely thanks for your careful assessment and constructive meta-review. We greatly appreciate your recognition of our work, particularly the natural compatibility between timestep-aware registration and progressive diffusion, and the broad empirical validation across fusion, segmentation, and registration tasks. Regarding the concerns raised in your meta-review, we provide the following clarifications and additional evidence:\n\n**1.The novelty relative to source-image-constrained diffusion fusion and diffusion-based registration:**\n\nOur work fundamentally investigates **how diffusion models can effectively model the image fusion task without explicitly constructing a forward process from real or pseudo-fused targets**. Existing methods rely on constructing a standard forward process for diffusion training and therefore typically either use pseudo-fused targets, making performance dependent on pseudo-label quality, or train on the original modality images, creating a mismatch between the training targets and the desired fused output. In contrast, our implicit-forward process **bypasses this dependency while incorporating fusion objectives to model the fusion task.** We further introduce a **time-aware joint registration–fusion framework**, where registration and fusion progressively provide reciprocal guidance throughout the diffusion trajectory. Thus, the novelty lies in the **implicit-forward fusion training paradigm and progressive joint optimization of fusion and registrantion**, rather than a simple combination of fusion constraints and diffusion registration.\n\n**2.What diffusion adds beyond deterministic iterative refinement:**\n\nUnlike deterministic iterative refinement, ResFusion learns a time-aware residual trajectory, where each denoising step corresponds to a distinct residual/noise level. This allows both fusion and registration to adapt their behavior across stages: **coarse structures are recovered at early steps, while anatomical details and deformation fields are progressively refined at later steps.** As shown in Supplementary Table 7, the deterministic iterative baseline underperforms the final diffusion-based model, while the progressive denoising results improve toward the final timestep. This highlights the advantage of diffusion: **it progressively refines the output through a learned denoising process**, which is also a key reason diffusion models achieve better generative quality.\n\n**3.Stronger support for the claimed fusion-to-registration effect:**\n\nCross-modal misalignment introduces structural inconsistencies, duplication, and blurring in the fused image, thereby increasing the fusion loss. Consequently, the fusion loss can indirectly guide the registration network toward more precise deformation estimation. We validate this fusion-guided registration effect by comparing ResFusion with a **registration-only variant**, which removes the fusion module and retains only the diffusion-based registration module. \n\nDue to the character limit, we cannot include the full numerical results here. Please refer to our responses to **Reviewer ZatH, Q4**, and **Reviewer kxY3, Q2 & Weakness 2 & Weakness 3** for the detailed results.\n\n**4.The method for synthetically generated misalignment:**\n\nAccording to reference [1], ResFusion is constructed by artificially perturbing already aligned source-modal images. Specifically, we designate one modality as deformable and, during training, randomly apply global shifts and smooth local non-rigid deformations, producing misaligned images with anatomical positional discrepancies relative to the other modality. This establishes supervision between “misaligned inputs” and “originally aligned images” without requiring ground-truth clinical deformation annotations, while retaining a degree of generalizability to real-world clinical scenarios. Please refer to our responses to **Reviewer ZatH, Q2 & Weakness 4**, **Reviewer xqFE, Q1** and **Reviewer kxY3, Q2 & Weakness 4** for the clinical analysis.\n\n[1] Li H, Su D, Cai Q, et al. Bsafusion: A bidirectional stepwise feature alignment network for unaligned medical image fusion[C]//Proceedings of the AAAI conference on artificial intelligence. 2025, 39(5): 4725-4733.\n\n**5.Compared to the computational cost of diffusion models and lightweight joint baseline models:**\n\nWe have conducted comprehensive comparisons of computational cost. Due to the character limit, we cannot provide the detailed results here; please refer to our responses to **Reviewer ZatH, Q5 & Weakness 3**, **Reviewer xqFE, Q1**, and **Reviewer kxY3, Weakness 5**.\n\nIn addition to the concerns discussed above, we have provided detailed, point-by-point responses to all reviewer comments and will add the corresponding content into the revised version. \n\nThanks again for your time to review our manuscript, your review is invaluable and of great significance to our work. We sincerely respect and appreciate you!\n\nBest regard,\n\nAuthors"+ },+ "createdAt": "2026-07-28T15:02:30.095Z",+ "modifiedAt": "2026-11-19T17:00:23.989Z",+ "url": "https://openreview.net/forum?id=W44dmCYl89¬eId=HAl68IyOq3",+ "license": "CC-BY-4.0"+}
reviews/openreview/w44dmcyl89/notes/nx7awhz6o5.json added
+++ b/reviews/openreview/w44dmcyl89/notes/nx7awhz6o5.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "nx7aWHZ6o5",+ "replyTo": "Tc1Xda5oLg",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Clarification regarding the implementation of the experiment",+ "comment": "Thanks for your response. In fact, we implemented the experiment **exactly as you described**: the complete network was retained, while gradients from the fusion loss to T-RNet were blocked and all other settings remained unchanged. Since the registration module precedes the fusion module in the sequential pipeline, blocking the fusion-loss gradient completely decouples their optimization: **the fusion module no longer provides any supervision to the T-RNet, which is then optimized solely by the registration loss**. Therefore, this setting is **fully equivalent** to what we previously described as “removing the fusion module and retaining only the diffusion-based registration module.” Thus, the current comparison directly validates the claimed guidance provided by the fusion objective to the registration module. We will explicitly clarify both the implementation and this equivalence in the revised manuscript."+ },+ "createdAt": "2026-07-29T04:39:31.127Z",+ "modifiedAt": "2026-11-19T17:00:24.115Z",+ "url": "https://openreview.net/forum?id=W44dmCYl89¬eId=nx7aWHZ6o5",+ "license": "CC-BY-4.0"+}
reviews/openreview/w44dmcyl89/notes/oau3vec3ou.json added
+++ b/reviews/openreview/w44dmcyl89/notes/oau3vec3ou.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "oaU3Vec3Ou",+ "replyTo": "nx7aWHZ6o5",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer kxY3",+ "content": {+ "comment": "The authors have addressed my remaining concern. I increase my rating."+ },+ "createdAt": "2026-08-03T12:51:25.933Z",+ "modifiedAt": "2026-11-19T17:00:24.064Z",+ "url": "https://openreview.net/forum?id=W44dmCYl89¬eId=oaU3Vec3Ou",+ "license": "CC-BY-4.0"+}
reviews/openreview/w44dmcyl89/notes/reoszlqiar.json added
+++ b/reviews/openreview/w44dmcyl89/notes/reoszlqiar.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "reoSzLQiAr",+ "replyTo": "Tc1Xda5oLg",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thanks for your response. As we previously explained, **we implemented the experiment exactly as you described**: the complete network was retained, while gradients from the fusion loss to T-RNet were blocked and all other settings remained unchanged. \n\nYour concerns stem from a misunderstanding of our previous description, because in terms of T-RNet optimization, this implementation is **completely equivalent** to \"removing the fusion module and retaining only the diffusion-based registration module\".\n\nTo further verify this equivalence, we conducted an additional experiment in which we **physically removed the fusion module and retained only the diffusion-based registration module**. For a strictly controlled comparison, all other experimental settings were kept identical, including the random seed, learning rate, optimizer, training iterations, data splits.\n\nThe quantitative results obtained by this implementation are exactly the same as those of the previous setting (preserving the complete network but blocking the gradient from the fusion loss to the T-RNet):\n\n| Method | BraTs | | Pelvis | | Prostate | | CT & MRI | | PET & MRI | | SPECT & MRI | |\n|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|\n| | NCC | RMSE | NCC | RMSE | NCC | RMSE | NCC | RMSE | NCC | RMSE | NCC | RMSE |\n| Registration Only | 0.8921 | 0.0585 | 0.8636 | 0.0847 | 0.9033 | 0.0542 | 0.9129 | 0.1311 | 0.9758 | 0.0577 | 0.9828 | 0.0302 |\n| Complete Network (block gradients from fusion loss) | 0.8921 | 0.0585 | 0.8636 | 0.0847 | 0.9033 | 0.0542 | 0.9129 | 0.1311 | 0.9758 | 0.0577 | 0.9828 | 0.0302 |\n| **ResFusion** | **0.9817** | **0.0305** | **0.9347** | **0.0528** | **0.9164** | **0.0523** | **0.9138** | **0.1295** | **0.9810** | **0.0528** | **0.9832** | **0.0301** |\n\nThese identical results empirically confirm that detaching the fusion-loss gradient from T-RNet is fully equivalent, with respect to T-RNet optimization, to directly removing the downstream fusion module. They also confirm that the current comparison genuinely isolates and validates the guidance provided by the fusion objective to the registration module. We will include this implementation detail and equivalence verification in the revised manuscript."+ },+ "createdAt": "2026-08-01T14:59:41.848Z",+ "modifiedAt": "2026-11-19T17:00:24.012Z",+ "url": "https://openreview.net/forum?id=W44dmCYl89¬eId=reoSzLQiAr",+ "license": "CC-BY-4.0"+}
reviews/openreview/w44dmcyl89/notes/tc1xda5olg.json added
+++ b/reviews/openreview/w44dmcyl89/notes/tc1xda5olg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Tc1Xda5oLg",+ "replyTo": "RMKTzd1Jol",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer kxY3",+ "content": {+ "comment": "Thank you for the helpful response. I am still uncertain whether the current comparison truly demonstrates the claimed fusion-to-registration guidance. Removing the fusion module changes both the model architecture and the training objective, so the observed improvement cannot be attributed specifically to feedback from the fusion loss. A cleaner control would retain the complete ResFusion architecture while blocking gradients from the fusion loss to T-RNet, with all other settings unchanged. This would more directly test the proposed feedback mechanism."+ },+ "createdAt": "2026-07-29T02:21:56.674Z",+ "modifiedAt": "2026-11-19T17:00:23.966Z",+ "url": "https://openreview.net/forum?id=W44dmCYl89¬eId=Tc1Xda5oLg",+ "license": "CC-BY-4.0"+}
reviews/openreview/w44dmcyl89/notes/tvsrxxinqw.json added
+++ b/reviews/openreview/w44dmcyl89/notes/tvsrxxinqw.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "tVsrXXINQW",+ "replyTo": "KZEKglRd15",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely appreciate your recognition of our work and your increased score. In the revised version, we will incorporate the corresponding clarifications and supplementary details into the revised manuscript following your suggestions. Thanks again!"+ },+ "createdAt": "2026-07-30T06:23:05.023Z",+ "modifiedAt": "2026-11-19T17:00:24.132Z",+ "url": "https://openreview.net/forum?id=W44dmCYl89¬eId=tVsrXXINQW",+ "license": "CC-BY-4.0"+}
reviews/openreview/w44dmcyl89/notes/ut5dlvxyg8.json added
+++ b/reviews/openreview/w44dmcyl89/notes/ut5dlvxyg8.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "uT5dlVXYG8",+ "replyTo": "oaU3Vec3Ou",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely appreciate your recognition of our work and your increased score. In the revised version, we will incorporate the corresponding clarifications and supplementary details following your suggestions. Thanks again!"+ },+ "createdAt": "2026-08-03T13:27:53.532Z",+ "modifiedAt": "2026-11-19T17:00:23.899Z",+ "url": "https://openreview.net/forum?id=W44dmCYl89¬eId=uT5dlVXYG8",+ "license": "CC-BY-4.0"+}