potentialpaper

ResFusion: Medical Image Fusion Driven by Implicit-Forward Diffusion and Time-aware Joint Optimization

Import NeurIPS 2026 submission W44dmCYl89: 8 notes

@openreview[bot] · 2026-11-22 17:57 UTC · dd934a068a37

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,28 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "W44dmCYl89"
+ }
+ ],
+ "title": "ResFusion: Medical Image Fusion Driven by Implicit-Forward Diffusion and Time-aware Joint Optimization",
+ "authors": [
+ "Jiahua Xu",
+ "Dawei Zhou",
+ "Zhengkun Yu",
+ "Lei Hu",
+ "Lecong Xiong",
+ "Zaiyi Liu",
+ "Nannan Wang",
+ "Xinbo Gao"
+ ],
+ "abstract": "Standard training of diffusion models typically relies on a forward diffusion process anchored by ground-truth target images. However, in image fusion tasks, the scarcity of real fused images makes it difficult to formulate a forward process, thereby precluding the standard training. Fortunately, our visual analysis reveals that image fusion can be effectively modeled without standard training or reliance on the real images. Nevertheless, the misalignment of input image pairs remains a significant bottleneck for fusion quality. Recognizing that one-off registration is ill-suited to the progressive generation of diffusion models, we propose a unified registration-fusion framework driven by a time-aware joint optimization mechanism. Specifically, we design a time-aware registration network to progressively optimize registration to guide fusion, while the fusion results provide feedback constraints to the registration network at each time step. This mechanism facilitates joint optimization of registration and fusion, significantly improving the quality of fused results. Experimental results show that the proposed method performs excellently on multiple datasets, validating its effectiveness and superiority.",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/w44dmcyl89/forms.json added

+++ b/reviews/openreview/w44dmcyl89/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/w44dmcyl89/notes/6j9k7hac56.json added

+++ b/reviews/openreview/w44dmcyl89/notes/6j9k7hac56.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "6J9K7hAc56",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair SZLB",
+ "content": {
+ "metareview": "ResFusion unifies medical image registration and fusion through implicit-forward diffusion and a timestep-conditioned registration network, T-RNet. The deformation field evolves during denoising, and the registration and fusion modules are jointly optimized. Experiments cover six fusion tasks on four public datasets, with additional segmentation and registration evaluations.\n\nThe recurring strengths are the relevance of the problem, the natural fit between timestep-conditioned registration and progressive diffusion, and the broad empirical evaluation. ResFusion reports strong performance on most fusion metrics, while the segmentation and registration studies provide additional supporting evidence.\n\nIndeed, integration can be a valid contribution, but the distinct contribution is not yet sufficiently isolated. The rebuttal should clarify the novelty relative to source-image-constrained diffusion fusion and diffusion-based registration, and explain what diffusion adds beyond deterministic iterative refinement. The claimed fusion-to-registration effect also needs stronger support or narrower wording. The authors should clarify the use of synthetically generated misalignment and frame the computational cost relative to both diffusion and lightweight joint baselines."
+ },
+ "createdAt": "2026-07-22T09:43:49.427Z",
+ "modifiedAt": "2026-11-18T15:21:16.204Z",
+ "url": "https://openreview.net/forum?id=W44dmCYl89&noteId=6J9K7hAc56",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/w44dmcyl89/notes/afltgdnku9.json added

+++ b/reviews/openreview/w44dmcyl89/notes/afltgdnku9.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "AflTgdNkU9",
+ "replyTo": "xc29mBd6NK",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Thanks for your careful review. We have the following explanation for your concerns:\n\n**Q1 & Weakness 1:**\n\nCompared to DDPM/DDIM, our method also provides a **novel** diffusion framework that requires **no ground-truth fused images**, explicitly **models the fusion objective**, and supports **efficient few-step generation**. We respectfully clarify that ResFusion is not simply a superposition of existing technologies. Our work fundamentally investigates **how diffusion models can effectively model the image fusion task without explicitly constructing a forward process from real or pseudo-fused targets**. Existing methods rely on constructing a standard forward process for diffusion training and therefore typically either use pseudo-fused targets, making performance dependent on pseudo-label quality, or train on the original modality images, creating a mismatch between the training targets and the desired fused output. In contrast, our implicit-forward process **bypasses this dependency while incorporating fusion objectives to model the fusion task.** We further introduce a **time-aware joint registration–fusion framework**, where registration and fusion progressively provide reciprocal guidance throughout the diffusion trajectory. Thus, the novelty lies in the implicit-forward fusion training paradigm and progressive joint optimization, rather than a simply a superposition of existing technologies.\n\n**Weakness 2:**\n\nWe have provided a comprehensive quantitative evaluation of registration on all datasets using the metrics NCC and RMSE in Table 4 of the Supplementary Material. These results complement the qualitative visualizations and demonstrate outstanding registration performance across different modality combinations.\n\n**Q2 & Weakness 4:**\n\nThank you for raising this concern. Real-world clinical misalignment commonly arises from patient motion and organ or tissue deformation. The rigid and non-rigid transformation strategy used in our study is designed to approximate these common sources of spatial variation, and therefore produces synthetic misalignment that resembles clinically relevant deformation patterns to a certain extent. This provides a reasonable basis for expecting a model trained with such transformations to generalize to real-world clinical misalignment. To further validate this generalization beyond synthetic settings, we conducted a blinded clinical user study on 30 real clinical images of the prostate, including five cases with severe deformation and five cases with modality-specific anatomical absence. Two radiologists with three years of diagnostic experience independently evaluated the results using a five-point Likert scale, without access to clinical details or biopsy results. All images were presented in random order to minimize evaluation bias. When their assessments were consistent, the corresponding scores were adopted; otherwise, a senior radiologist with 20 years of experience performed an additional review and made the final decision.\n\nThe evaluation covered four dimensions: **Registration Quality**, which evaluates the alignment of cross-modal anatomical structures; **Fusion Quality**, which evaluates the fusion of complementary information; **Anatomical Preservation**, which assesses whether anatomical structures exhibit missing regions or distortions; and **Overall Quality**, which reflects the overall reliability and clinical applicability of the fused results. **Higher scores indicate better performance across all dimensions.**\n\n| Method | Registration Quality | Fusion Quality | Anatomical Preservation | Overall Quality |\n|---|---:|---:|---:|---:|\n| DDFM | 2.33±0.59 | 2.47±0.52 | 2.55±0.56 | 2.42±0.54 |\n| CCF | 2.33±0.59 | 2.60±0.61 | 2.62±0.54 | 2.58±0.51 |\n| UMF-CMGR | 2.95±0.48 | 3.00±0.51 | 2.90±0.53 | 3.03±0.52 |\n| SuperFusion | 3.17±0.44 | 3.23±0.49 | 3.23±0.49 | 3.18±0.43 |\n| IMF | 3.18±0.55 | 3.25±0.39 | 3.25±0.25 | 3.23±0.47 |\n| PAMRFuse+ | 3.38±0.49 | 3.57±0.34 | 3.47±0.32 | 3.43±0.43 |\n| BSAFusion | 3.20±0.45 | 3.38±0.39 | 3.05±0.50 | 3.22±0.47 |\n| **ResFusion** | **4.23±0.41** | **4.55±0.30** | **4.28±0.28** | **4.42±0.32** |\n\nThe expert evaluations consistently favor ResFusion across all assessment dimensions, indicating that it generalizes better than the competing methods to clinically realistic misalignment while preserving anatomical structures and producing reliable fused results. We will add this analysis into the Experiments of the revised version.\n\n**Q3:**\n\nThank you for raising this question. As discussed in our response to Q2 and the clinical user-study table above, radiologists selected five cases with severe deformation and five cases with modality-specific anatomical absence. ResFusion remained robust to large deformations, benefiting from the rigid and non-rigid transformations simulated during training and its coarse-to-fine registration design. For modality-specific anatomical absence, the pixel-wise maximum constraint encourages the model to retain the stronger anatomical response from the complementary modality. Since absent structures generally yield lower responses in one modality, information from the other modality can dominate the fusion target and compensate for the missing anatomy. The expert evaluation results in the table above consistently demonstrate that ResFusion can effectively preserve clinically significant anatomical structures while maintaining high fusion quality in clinical applications.\n\n\n**Q4:**\n\nTo verify the effect of joint optimization on registration, we validate this fusion-guided registration effect by comparing ResFusion with a **registration-only variant**, which removes the fusion module and retains only the diffusion-based registration module.\n\n| Method | BraTs | | Pelvis | | Prostate | | CT & MRI | | PET & MRI | | SPECT & MRI | |\n|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|\n| | NCC | RMSE | NCC | RMSE | NCC | RMSE | NCC | RMSE | NCC | RMSE | NCC | RMSE |\n| Registration Only | 0.8921 | 0.0585 | 0.8636 | 0.0847 | 0.9033 | 0.0542 | 0.9129 | 0.1311 | 0.9758 | 0.0577 | 0.9828 | 0.0302 |\n| **ResFusion** | **0.9817** | **0.0305** | **0.9347** | **0.0528** | **0.9164** | **0.0523** | **0.9138** | **0.1295** | **0.9810** | **0.0528** | **0.9832** | **0.0301** |\n\nResFusion consistently improves registration across all modality combinations, with particularly pronounced gains on the larger-scale BraTs and Pelvis datasets. Taken together, these registration results and Supplementary Tables 5 and 6 show that both the registration-only and fusion-only variants underperform the complete ResFusion framework. This confirms that the gains arise from the **time-aware joint optimization of registration and fusion**, rather than from either component.\n\n\n**Q5 & Weakness 3:**\n\nWe have already reported the inference-time comparison with existing methods in Table 9 of the Supplementary Material, as reproduced below.\n\n| Method | Inference Time (s) |\n|:---|---:|\n| DDFM | 7.30 |\n| CCF | 23.19 |\n| UMF-CMGR | 0.06 |\n| SuperFusion | 0.05 |\n| IMF | 0.07 |\n| PAMRFuse+ | 0.12 |\n| BSAFusion | 0.05 |\n| **ResFusion** | **0.37** |\n\nAlthough lightweight models are faster, our blinded clinical study shows that this efficiency comes with reduced robustness under challenging misalignment and anatomical variations. ResFusion offers a more favorable accuracy–robustness trade-off, while its sub-second runtime remains practical for clinical preprocessing and offline analysis. It is also substantially faster than diffusion-based DDFM and CCF.\n\nAs discussed in the Supplementary Material, ResFusion adds only about one minute per epoch. The reverse rollout is performed only when T=4, and gradients through intermediate reverse steps are detached, retaining only the final-step prediction gradient to reduce memory and computational costs. A similar gradient-truncation strategy has been validated in Self Forcing [1]. We will further discuss these deployment and training trade-offs and explore model compression and lightweight architectures in future work.\n\n[1] Huang X, Li Z, He G, et al. Self forcing: Bridging the train-test gap in autoregressive video diffusion[J]. Advances in Neural Information Processing Systems, 2025, 38: 167283-167308.\n\nWe sincerely hope that the above answers will solve your concerns and obtain your increase in the score."
+ },
+ "createdAt": "2026-07-27T12:39:29.483Z",
+ "modifiedAt": "2026-11-18T17:15:45.109Z",
+ "url": "https://openreview.net/forum?id=W44dmCYl89&noteId=AflTgdNkU9",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/w44dmcyl89/notes/kud7wb2b6j.json added

+++ b/reviews/openreview/w44dmcyl89/notes/kud7wb2b6j.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "kUD7WB2b6J",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "ResFusion unifies medical image registration and fusion through implicit-forward diffusion and a timestep-conditioned registration network, T-RNet. The deformation field evolves during denoising, and the registration and fusion modules are jointly optimized. Experiments cover six fusion tasks on four public datasets, with additional segmentation and registration evaluations.\n\nThe recurring strengths are the relevance of the problem, the natural fit between timestep-conditioned registration and progressive diffusion, and the broad empirical evaluation. ResFusion reports strong performance on most fusion metrics, while the segmentation and registration studies provide additional supporting evidence.\n\nIndeed, integration can be a valid contribution, but the distinct contribution is not yet sufficiently isolated. The rebuttal should clarify the novelty relative to source-image-constrained diffusion fusion and diffusion-based registration, and explain what diffusion adds beyond deterministic iterative refinement. The claimed fusion-to-registration effect also needs stronger support or narrower wording. The authors should clarify the use of synthetically generated misalignment and frame the computational cost relative to both diffusion and lightweight joint baselines.",
+ "final_justification": "ResFusion addresses a practically relevant problem in medical image fusion by jointly considering the lack of fused ground truth and spatial misalignment, using an implicit-forward diffusion formulation together with time-aware registration and joint optimization. The paper is evaluated across multiple fusion tasks, and shows strong overall empirical performance. The main concerns raised in the initial reviews were the degree of methodological novelty, the evidence for fusion-to-registration feedback, generalization beyond synthetic misalignment, and computational cost. During rebuttal, the authors provided additional clarification and experimental evidence addressing these points, including quantitative registration analysis, evaluation on naturally misaligned clinical images, statistical significance analysis, and further discussion of computational trade-offs. The remaining concern was further examined with an additional controlled experiment, after which the reviewer explicitly stated that the concern had been addressed and increased the rating. More broadly, all three reviewers ultimately gave a borderline-accept assessment, with their final justifications indicating that the rebuttal resolved or substantially addressed their concerns."
+ },
+ "createdAt": "2026-09-24T11:20:31.947Z",
+ "modifiedAt": "2026-11-18T14:54:57.888Z",
+ "url": "https://openreview.net/forum?id=W44dmCYl89&noteId=kUD7WB2b6J",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/w44dmcyl89/notes/kzekglrd15.json added

+++ b/reviews/openreview/w44dmcyl89/notes/kzekglrd15.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "KZEKglRd15",
+ "replyTo": "lq5WA5sEj7",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Thanks for your careful review. We have the following explanation for your concerns:\n\n**Weakness 1:**\n\nAlthough ResFusion has substantially more parameters and FLOPs than lightweight models, this increase does not materially hinder its practical clinical deployment. Its model size remains manageable on standard GPU-equipped workstations, and its inference time is only 0.37 s per image, accounting for a negligible portion of the overall diagnostic workflow. More importantly, the additional computational cost yields substantially stronger generalization under challenging clinical scenarios. In medical applications, robustness to severe misalignment and anatomical variation is often more clinically valuable than a marginal reduction in processing time, as unreliable fusion results may directly affect diagnostic confidence and patient care. To validate the clinical applicability, we conducted a blinded clinical user study on 30 real clinical images of the prostate, including five cases with severe deformation and five cases with modality-specific anatomical absence. Two radiologists with three years of diagnostic experience independently evaluated the results using a five-point Likert scale, without access to clinical details or biopsy results. All images were presented in random order to minimize evaluation bias. When their assessments were consistent, the corresponding scores were adopted; otherwise, a senior radiologist with 20 years of experience performed an additional review and made the final decision.\n\nThe evaluation covered four dimensions: **Registration Quality**, which evaluates the alignment of cross-modal anatomical structures; **Fusion Quality**, which evaluates the fusion of complementary information; **Anatomical Preservation**, which assesses whether anatomical structures exhibit missing regions or distortions; and **Overall Quality**, which reflects the overall reliability and clinical applicability of the fused results. **Higher scores indicate better performance across all dimensions.**\n\n| Method | Registration Quality | Fusion Quality | Anatomical Preservation | Overall Quality |\n|---|---:|---:|---:|---:|\n| DDFM | 2.33±0.59 | 2.47±0.52 | 2.55±0.56 | 2.42±0.54 |\n| CCF | 2.33±0.59 | 2.60±0.61 | 2.62±0.54 | 2.58±0.51 |\n| UMF-CMGR | 2.95±0.48 | 3.00±0.51 | 2.90±0.53 | 3.03±0.52 |\n| SuperFusion | 3.17±0.44 | 3.23±0.49 | 3.23±0.49 | 3.18±0.43 |\n| IMF | 3.18±0.55 | 3.25±0.39 | 3.25±0.25 | 3.23±0.47 |\n| PAMRFuse+ | 3.38±0.49 | 3.57±0.34 | 3.47±0.32 | 3.43±0.43 |\n| BSAFusion | 3.20±0.45 | 3.38±0.39 | 3.05±0.50 | 3.22±0.47 |\n| **ResFusion** | **4.23±0.41** | **4.55±0.30** | **4.28±0.28** | **4.42±0.32** |\n\nThese results indicate that ResFusion offers greater robustness and clinical generalizability than lightweight methods, while its sub-second inference remains practical for clinical application. We will explicitly discuss this robustness–efficiency trade-off in the revised version, and explore model compression and lightweight variants in future work.\n\nWe further conducted a parameter-efficiency analysis, calculated by dividing the average VIF across all datasets by the number of model parameters in millions:\n\n**Parameter Efficiency = Average VIF / Parameters (M)**\n\nFor a representative comparison, we report **BSAFusion**, which achieves the highest parameter efficiency among the lightweight baselines, together with the diffusion-based methods DDFM and CCF.\n\n| Method | VIF-based Parameter Efficiency ↑ |\n|:---|---:|\n| DDFM | 0.000625 |\n| CCF | 0.000660 |\n| **BSAFusion** | **0.056484** |\n| ResFusion | 0.002425 |\n\nResFusion exhibits a clear parameter-efficiency gap compared with the lightweight BSAFusion, reflecting the additional capacity required by its diffusion and registration components. Nevertheless, its parameter efficiency is approximately 3.88 and 3.67 times higher than those of diffusion-based DDFM and CCF, respectively, demonstrating a substantially more efficient design within the diffusion paradigm. More importantly, the additional model capacity translates into markedly stronger generalization to challenging clinical scenarios, including severe misalignment and modality-specific anatomical variation, as supported by the consistently higher expert evaluations in registration quality, anatomical preservation, fusion quality, and overall clinical reliability.\n\n**Weakness 2:**\n\nThank you for this comment. ResFusion already surpasses the deterministic baseline at t=3 in quantitative metrics. However, the t=3 output is still an intermediate state and contains residual noise and slight structural blurring, which may obscure subtle anatomical details and reduce its reliability for clinical diagnosis. Similar cases, where intermediate diffusion states outperform deterministic baselines quantitatively while remaining visually incomplete, are commonly observed in diffusion models [1,2]. The fourth step therefore does more than further improve the quantitative metrics: it removes residual noise, sharpens anatomical boundaries, and completes the fused image toward a clinically reliable endpoint. In the revised version, we will visualize the evolution of the generated images throughout the diffusion process to clearly demonstrate the progressive removal of noise and recovery of anatomical structures.\n\n[1] Fei B, Lyu Z, Pan L, et al. Generative diffusion prior for unified image restoration and enhancement[C]//Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. 2023: 9935-9946.\n\n[2] Wang Z, Zhang Z, Zhang X, et al. Dr2: Diffusion-based robust degradation remover for blind face restoration[C]//Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition. 2023: 1704-1713.\n\n**Weakness 3:**\n\nThank you for this helpful suggestion. The detailed ablation results were originally placed in the Supplementary Material to accommodate the main-paper page limit. In the revised version, we will reorganize Section 5.4 by moving the most critical ablations—particularly Tables 5 and 6, which validate the time-aware registration network and joint optimization design—into the main paper and adding explicit quantitative analysis to better substantiate the core methodological claims.\n\n**Weakness 4:**\n\nThank you for this helpful suggestion. In the revised version, we will clarify the relationship between the simulated rigid and non-rigid transformations and clinically realistic misalignment, and more carefully define the scope of our generalization claim. As discussed in Q1, we further evaluated ResFusion on real clinical images, including cases with severe deformation and modality-specific anatomical absence. The favorable radiologist assessments indicate that the simulated transformations capture clinically relevant misalignment patterns to a meaningful extent. Moreover, the coarse-to-fine, time-aware registration mechanism progressively refines deformation estimation, thereby supporting robustness to real clinical misalignment to a certain extent.\n\n**Weakness 5:**\n\nThank you for this helpful suggestion. Following your recommendation, we conducted **statistical significance tests** on all test sets and report the significance of each comparison across all datasets and metrics. We also computed **bootstrap 95% confidence intervals**. Due to the rebuttal length limit, we report the confidence intervals only for ResFusion, while the statistical significance of each competing method against ResFusion is summarized using * and **. Specifically, * indicates a statistically significant difference with p<0.05, while ** indicates a highly significant difference with p<0.01. Blank cells indicate non-significant differences or cases where ResFusion is not directionally better.\n\n|Method|BraTs|||||Pelvis|||||Prostate|||||\n|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|\n||MI|VIF|QAB/F|SSIM|EI|MI|VIF|QAB/F|SSIM|EI|MI|VIF|QAB/F|SSIM|EI|\n|DDFM|**|**|**|**|**|**|**|**|**|**|**|**|**|**|**|\n|CCF|**|**|**|**|**|**|**|**|**|**|**|**|**|**|**|\n|UMF-CMGR|**|**|**|**|**|**|**|**|**|**|**|**|**|**|**|\n|SuperFusion|**|**|**|**|**|**|**|**|**|**|**|**|**|**|**|\n|IMF|**|**|**|**|**|**|**|**|**|**|**|**|**|**|**|\n|PAMRFuse+|**|**|**|**||**|**|**|**||**|**|**|**|**|\n|BSAFusion|**|**|**|**|**|**|**|**|**|**|**|**|**|**|**|\n|**ResFusion**|[3.867, 3.895]|[0.837, 0.847]|[0.576, 0.580]|[1.714, 1.722]|[0.174, 0.176]|[3.759, 3.793]|[0.687, 0.695]|[0.525, 0.529]|[1.425, 1.433]|[0.143, 0.145]|[3.763, 3.973]|[0.825, 0.875]|[0.553, 0.587]|[1.501, 1.559]|[0.273, 0.299]|\n\n|Method|CT & MRI|||||PET & MRI|||||SPECT & MRI|||||\n|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|\n||MI|VIF|QAB/F|SSIM|EI|MI|VIF|QAB/F|SSIM|EI|MI|VIF|QAB/F|SSIM|EI|\n|DDFM|**|**|**|**|**|**|**|**|**|**|**|**|**|**|**|\n|CCF|**|**|**|**|**|**|**|**|**|**|**|**|**|**|**|\n|UMF-CMGR|**|**|**|**|**|**|**|**|**|**|**|**|**|**|**|\n|SuperFusion|**|**|**|**|**|**|**|**|**|**|**|**|**|**|**|\n|IMF|**|**|**|**|**|**|**|**|**|**|**|**|**|**|**|\n|PAMRFuse+||*|*|**|**|**|**|**|**||**|**|**|**|**|\n|BSAFusion|**|**||||**|**|**|**|**|**|**|**|**||\n|**ResFusion**|[2.949, 3.223]|[0.457, 0.515]|[0.369, 0.401]|[1.395, 1.443]|[0.262, 0.294]|[3.633, 3.885]|[0.806, 0.834]|[0.749, 0.775]|[1.373, 1.439]|[0.435, 0.479]|[3.566, 3.866]|[0.776, 0.816]|[0.707, 0.741]|[1.442, 1.528]|[0.250, 0.288]|\n\nThe results demonstrate that ResFusion significantly outperforms most competing methods across datasets and metrics, while its relatively narrow confidence intervals indicate stable performance. We will provide complete confidence intervals for all methods in the revised supplementary material.\n\nWe sincerely hope that the above answers will solve your concerns and obtain your increase in the score."
+ },
+ "createdAt": "2026-07-27T12:40:16.720Z",
+ "modifiedAt": "2026-11-18T17:15:46.398Z",
+ "url": "https://openreview.net/forum?id=W44dmCYl89&noteId=KZEKglRd15",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/w44dmcyl89/notes/lq5wa5sej7.json added

+++ b/reviews/openreview/w44dmcyl89/notes/lq5wa5sej7.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "lq5WA5sEj7",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer xqFE",
+ "content": {
+ "summary": "ResFusion tackles a real problem: how to use diffusion models for image fusion when no ground-truth fused images exist, and how to handle spatial misalignment without baking in a single static registration. Letting the registration field evolve across diffusion timesteps is a smart idea. The results across four datasets and six fusion tasks are solid, and the downstream segmentation check adds credibility.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths:\n1. A static one-off deformation field cannot adapt to the progressive denoising of diffusion models. Having the registration network receive the current timestep and update the field at each step is a clean solution. \n\n2. Rather than synthesizing pseudo-targets or relying on pretrained generative priors, the paper shows that source images can serve as the forward-process target, with the fusion output recovered through a modified reverse process (Eq. 9).\n\nWeaknesses:\n1. ResFusion: 308.22M parameters. BSAFusion: 9.69M (Table 9). Inference: 0.37s vs. 0.05s. FLOPs: 461.4G vs. 115.7G. The conclusion calls this a \"minor trade-off,\" which is not accurate. A 32x parameter gap is a fundamental design choice that affects clinical deployability. A parameter-efficiency analysis or a compressed variant is needed.\n\n2. Table 7 shows the deterministic baseline (static A and B, same architecture) achieves MI=3.344 and Q_AB/F=0.502, outperforming the diffusion model at t=2 (Q_AB/F=0.267). The diffusion process burns three of its four steps catching up to a non-diffusion variant. The paper should discuss what the diffusion process contributes at T=4 beyond what a multi-step deterministic refinement would provide.\n\n3. Section 5.4 verbally references Tables 5-9 without a single quantitative result. For a NeurIPS submission, the ablations that directly support the method's core claims (particularly Tables 5 and 6) belong in the main paper.\n\n4. Misalignment is simulated via random rigid and non-rigid deformations following BSAFusion [17]. This is standard practice, but the paper motivates itself with \"real clinical scenarios.\" Clinical misalignment from patient movement, protocol changes, or organ deformation can be systematic and tissue-specific, not random. This should be acknowledged as a limitation.\n\n5. The NeurIPS Checklist marks statistical significance as [No] with the justification \"too computationally expensive.\" Bootstrap confidence intervals on the test set are inexpensive and would address this.",
+ "quality": 2,
+ "clarity": 3,
+ "significance": 2,
+ "originality": 2,
+ "questions": "See weakness.",
+ "limitations": "See weakness.",
+ "rating": 4,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "Thank you for the author's detailed reply, which resolved my concerns. However, I am skeptical about the author adding so much content to the promised revised version, so I can only raise my score by one point."
+ },
+ "createdAt": "2026-06-24T12:03:09.199Z",
+ "modifiedAt": "2026-11-18T13:39:16.345Z",
+ "url": "https://openreview.net/forum?id=W44dmCYl89&noteId=lq5WA5sEj7",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/w44dmcyl89/notes/rmktzd1jol.json added

+++ b/reviews/openreview/w44dmcyl89/notes/rmktzd1jol.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "RMKTzd1Jol",
+ "replyTo": "tC67jU3oU4",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Thanks for your careful review. We have the following explanation for your concerns:\n\n**Q1 & Weakness 1:** .\n\nThank you for this thoughtful comment. We respectfully clarify that ResFusion is not merely an integration of source-image constraints into a residual diffusion framework. Our work fundamentally investigates **how diffusion models can effectively model the image fusion task without explicitly constructing a forward process from real or pseudo-fused targets**. Existing methods rely on constructing a standard forward process for diffusion training and therefore typically either use pseudo-fused targets, making performance dependent on pseudo-label quality, or train on the original modality images, creating a mismatch between the training targets and the desired fused output. In contrast, our implicit-forward process **bypasses this dependency while incorporating fusion objectives to model the fusion task.** We further introduce a **time-aware joint registration–fusion framework**, where registration and fusion progressively provide reciprocal guidance throughout the diffusion trajectory. Thus, the novelty lies in the implicit-forward fusion training paradigm and progressive joint optimization, rather than a simple combination of fusion constraints and diffusion.\n\n\n**Q2 & Weakness 2 & Weakness 3:**\n\nThank you for this comment. Our contribution is not diffusion-based progressive registration itself, but its integration into diffusion-based image fusion through a **time-aware joint optimization mechanism**. During training, registration progressively aligns the source modalities to facilitate fusion, while the fusion loss guides deformation refinement at each diffusion timestep. We will clearly articulate these contributions in the revised version.\n\nCross-modal misalignment introduces structural inconsistencies, duplication, and blurring in the fused image, thereby increasing the fusion loss. Consequently, the fusion loss can indirectly guide the registration network toward more precise deformation estimation. We validate this fusion-guided registration effect by comparing ResFusion with a **registration-only variant**, which removes the fusion module and retains only the diffusion-based registration module.\n\n| Method | BraTs | | Pelvis | | Prostate | | CT & MRI | | PET & MRI | | SPECT & MRI | |\n|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|:---|\n| | NCC | RMSE | NCC | RMSE | NCC | RMSE | NCC | RMSE | NCC | RMSE | NCC | RMSE |\n| Registration Only | 0.8921 | 0.0585 | 0.8636 | 0.0847 | 0.9033 | 0.0542 | 0.9129 | 0.1311 | 0.9758 | 0.0577 | 0.9828 | 0.0302 |\n| **ResFusion** | **0.9817** | **0.0305** | **0.9347** | **0.0528** | **0.9164** | **0.0523** | **0.9138** | **0.1295** | **0.9810** | **0.0528** | **0.9832** | **0.0301** |\n\nResFusion consistently improves registration across all modality combinations, with particularly pronounced gains on the larger-scale BraTs and Pelvis datasets. Taken together, these registration results and Supplementary Tables 5 and 6 show that both the registration-only and fusion-only variants underperform the complete ResFusion framework. This confirms that the gains arise from the **time-aware joint optimization of registration and fusion**, rather than from either component. In the revised version, we will clearly explain the mutual effectiveness between image registration and fusion.\n\n**Q2 & Weakness 4:**\n\nThank you for raising this concern. ResFusion was directly evaluated on naturally misaligned clinical images and consistently outperformed all competing methods in radiologist-assessed registration quality, fusion quality, anatomical preservation, and overall quality. Specifically, we conducted a blinded clinical user study on 30 real clinical images of the prostate, including five cases with severe deformation and five cases with modality-specific anatomical absence. Two radiologists with three years of diagnostic experience independently evaluated the results using a five-point Likert scale, without access to clinical details or biopsy results. All images were presented in random order to minimize evaluation bias. When their assessments were consistent, the corresponding scores were adopted; otherwise, a senior radiologist with 20 years of experience performed an additional review and made the final decision.\n\nThe evaluation covered four dimensions: **Registration Quality**, which evaluates the alignment of cross-modal anatomical structures; **Fusion Quality**, which evaluates the fusion of complementary information; **Anatomical Preservation**, which assesses whether anatomical structures exhibit missing regions or distortions; and **Overall Quality**, which reflects the overall reliability and clinical applicability of the fused results. **Higher scores indicate better performance across all dimensions.**\n\n| Method | Registration Quality | Fusion Quality | Anatomical Preservation | Overall Quality |\n|---|---:|---:|---:|---:|\n| DDFM | 2.33±0.59 | 2.47±0.52 | 2.55±0.56 | 2.42±0.54 |\n| CCF | 2.33±0.59 | 2.60±0.61 | 2.62±0.54 | 2.58±0.51 |\n| UMF-CMGR | 2.95±0.48 | 3.00±0.51 | 2.90±0.53 | 3.03±0.52 |\n| SuperFusion | 3.17±0.44 | 3.23±0.49 | 3.23±0.49 | 3.18±0.43 |\n| IMF | 3.18±0.55 | 3.25±0.39 | 3.25±0.25 | 3.23±0.47 |\n| PAMRFuse+ | 3.38±0.49 | 3.57±0.34 | 3.47±0.32 | 3.43±0.43 |\n| BSAFusion | 3.20±0.45 | 3.38±0.39 | 3.05±0.50 | 3.22±0.47 |\n| **ResFusion** | **4.23±0.41** | **4.55±0.30** | **4.28±0.28** | **4.42±0.32** |\n\nThe expert evaluations consistently favor ResFusion across all assessment dimensions, indicating that it generalizes better than the competing methods to clinically realistic misalignment while preserving anatomical structures and producing reliable fused results. Since dense ground-truth deformation fields are generally unavailable in clinical practice, this blinded expert assessment provides clinically meaningful evidence of real-world generalization.\n\n\n**Weakness 5:**\n\nAlthough ResFusion requires more parameters and FLOPs than lightweight models, its computational cost remains practical for clinical deployment. The model can be deployed on standard GPU-equipped workstations, and its inference time is only 0.37 s per image, representing a small fraction of a typical diagnostic workflow. More importantly, the additional computation yields substantially stronger robustness and generalization under challenging clinical conditions. In medical applications, reliable handling of severe misalignment and anatomical variation is often more important than marginal reductions in processing time, as inaccurate fusion may directly affect diagnostic confidence and patient care. We have reported the inference-time comparison with existing methods in Table 9 of the Supplementary Material, reproduced below.\n\n| Method | Inference Time (s) |\n|:---|---:|\n| DDFM | 7.30 |\n| CCF | 23.19 |\n| UMF-CMGR | 0.06 |\n| SuperFusion | 0.05 |\n| IMF | 0.07 |\n| PAMRFuse+ | 0.12 |\n| BSAFusion | 0.05 |\n| **ResFusion** | **0.37** |\n\nAlthough lightweight models are faster, our blinded clinical study shows that this efficiency comes with reduced robustness under challenging misalignment and anatomical variations. ResFusion offers a more favorable accuracy–robustness trade-off, while its sub-second runtime remains practical for clinical preprocessing and offline analysis. It is also substantially faster than diffusion-based DDFM and CCF.\n\nAs discussed in the Supplementary Material, ResFusion adds only about one minute per epoch. The reverse rollout is performed only when T=4, and gradients through intermediate reverse steps are detached, retaining only the final-step prediction gradient to reduce memory and computational costs. A similar gradient-truncation strategy has been validated in Self Forcing [1]. We will further discuss these deployment and training trade-offs and explore model compression and lightweight architectures in future work.\n\n[1] Huang X, Li Z, He G, et al. Self forcing: Bridging the train-test gap in autoregressive video diffusion[J]. Advances in Neural Information Processing Systems, 2025, 38: 167283-167308.\n\nWe sincerely hope that the above answers will solve your concerns and obtain your increase in the score."
+ },
+ "createdAt": "2026-07-27T12:41:55.957Z",
+ "modifiedAt": "2026-11-18T17:15:45.121Z",
+ "url": "https://openreview.net/forum?id=W44dmCYl89&noteId=RMKTzd1Jol",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/w44dmcyl89/notes/tc67ju3ou4.json added

+++ b/reviews/openreview/w44dmcyl89/notes/tc67ju3ou4.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "tC67jU3oU4",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer kxY3",
+ "content": {
+ "summary": "This paper proposes a unified medical image registration-fusion framework driven by implicit-forward diffusion and time-aware joint optimization, ResFusion. It aims to address two challenges: the absence of real fused ground-truth images and the spatial misalignment between multimodal inputs. To this end, ResFusion introduces an implicit-forward diffusion formulation to bypass standard diffusion training with unavailable fused targets, and further designs a time-aware registration network to progressively estimate deformation fields during the diffusion generation process. Experiments show promising performance in segmentation and registration.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths:\n1. ResFusion addresses the challenges: missing fused ground truth and spatially misaligned multimodal inputs. This is of considerable practical value for the real-world application of image fusion models.\n2. Instead of relying on a static one-shot registration field, ResFusion allows the deformation field to evolve along the diffusion timesteps, which matches the progressive generation nature of diffusion models. It can be intuitively imagined that this can enhance the performance of registration.\n3. The registration module provides spatially aligned guidance for fusion, while the fused result imposes feedback constraints on registration, making ResFusion more robust than a simple registration-fusion sequential pipeline.\n4. Compared with both independent registration-fusion methods and recent joint registration-fusion baselines. ResFusion demonstrates better performance.\n\nWeakness:\n1. The absence of real fused ground truth is a recognized setting in diffusion-based image fusion, and prior works try to address it using pseudo targets, source-image-driven constraints, or test-time optimization. In this work, the proposed implicit-forward formulation can also be interpreted as a source-image-driven constrained diffusion formulation, since the target fused image is ultimately specified by structural, intensity, and gradient constraints derived from the input modalities. Therefore, the contribution appears to be more of a task-specific integration of existing source-image-driven fusion constraints into a residual diffusion framework.\n2. Diffusion-based progressive registration has already been explored in prior image registration works, such as DiffuseMorph and DiffuseReg. The authors should more clearly position the contribution of ResFusion as the integration of timestep-aware registration into diffusion-based image fusion.\n3. Registration clearly guides fusion because the warped image is used as a conditional input. However, the reverse direction, namely fusion guiding registration, seems to rely mainly on indirect gradient back-propagation from the fusion loss. However, the fusion loss itself does not explicitly involve the deformation field or registration error, and there is no dedicated fusion-to-registration constraint showing how the fused result directly refines the deformation field. In other words, the mutual efficacy between image registration and fusion should be more clearly expounded and demonstrated.\n4. The experiments are conducted on real public medical datasets, but the unaligned setting appears to be simulated by deforming aligned image pairs. It is unclear whether ResFusion has been evaluated on naturally misaligned clinical data.\n5. The computational cost remains relatively high compared with several models. The authors should discuss the practical implications for clinical deployment, especially in time-sensitive workflows.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "1. How is the implicit-forward diffusion different from existing source-image-constrained diffusion fusion methods? \n2. Is the main contribution the diffusion-based registration itself, or its integration with image fusion? - Since the fusion loss does not explicitly include the deformation-related constraint, how does fusion guide registration? - How does ResFusion perform on real misaligned clinical data?",
+ "limitations": "Yes.",
+ "rating": 4,
+ "confidence": 5,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The authors have addressed my concerns, and I therefore increase my rating."
+ },
+ "createdAt": "2026-06-23T07:13:41.033Z",
+ "modifiedAt": "2026-11-18T13:39:18.181Z",
+ "url": "https://openreview.net/forum?id=W44dmCYl89&noteId=tC67jU3oU4",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/w44dmcyl89/notes/xc29mbd6nk.json added

+++ b/reviews/openreview/w44dmcyl89/notes/xc29mbd6nk.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "xc29mBd6NK",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer ZatH",
+ "content": {
+ "summary": "This paper proposes ResFusion, a unified framework for simultaneous medical image registration and fusion based on an implicit forward diffusion model and a time-aware joint optimization strategy. Instead of treating registration and fusion as two independent stages, the proposed method jointly optimizes both processes through a Time-aware Registration Network (T-RNet) that progressively estimates deformation fields during diffusion. The aligned images are then incorporated into a diffusion-based fusion network to generate anatomically consistent fused images while reducing artifacts caused by spatial misalignment. The method is extensively evaluated on six multi-modal fusion tasks across four public datasets and consistently outperforms previous registration-fusion methods in image quality metrics and downstream segmentation performance. The results demonstrate that jointly modeling registration and fusion leads to more accurate alignment, higher-quality fusion, and improved clinical utility.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "# Strengths\n- The paper introduces a unified diffusion-based framework that performs image registration and fusion simultaneously rather than sequentially, addressing a long-standing limitation of two-stage pipelines. \n- The proposed Time-aware Registration Network, progressive registration strategy, and joint optimization mechanism are coherently integrated and well motivated.\n- The method is evaluated on multiple public datasets covering MRI-CT, PET-MRI, SPECT-MRI, T1-T2, and T2-T2 Flair fusion tasks with comparisons against numerous recent state-of-the-art methods. \n14108_ResFusion_Medical_Image_.pdf\n- The paper validates the usefulness of fused images using downstream SAM-Med2D segmentation and registration analysis, demonstrating practical clinical value instead of relying only on image quality metrics.\n\n# Weaknesses\n- Although the integration of registration and fusion is elegant, many individual components (diffusion model, SwinUNet backbone, progressive registration, joint optimization) build upon existing techniques, making the overall methodological novelty somewhat incremental.\n- Registration quality is mainly demonstrated through qualitative visualization and indirect analysis, while comparisons using standard registration metrics are relatively insufficient.\n- The framework combines diffusion-based fusion with an additional registration network, increasing training complexity and computational cost despite the authors claiming limited overhead. \n- Only segmentation is evaluated as a downstream task. Additional applications such as diagnosis, detection, radiotherapy planning, or clinical decision support would better demonstrate the practical advantages of the fused images.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "- Why was the implicit forward diffusion process chosen instead of conventional DDPM/DDIM formulations? What empirical advantages does it provide beyond computational efficiency?\n- Since the registration network is supervised using aligned ground truth generated through synthetic deformation, how well would the framework generalize to real-world clinical misalignment where ground-truth deformation fields are unavailable?\n- How sensitive is the framework to large anatomical deformations or missing anatomical structures between modalities?\n- Does joint optimization always improve registration accuracy, or are there scenarios where the fusion objective negatively influences deformation estimation?\n- What is the inference time compared with existing joint registration-fusion frameworks, especially for clinical deployment?",
+ "limitations": "yes",
+ "rating": 4,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "N/A",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The rebuttal has addressed most of my concerns, and the revisions are consistent with the feedback from the other reviewers. Therefore, I lean toward a borderline accept."
+ },
+ "createdAt": "2026-06-27T12:25:55.566Z",
+ "modifiedAt": "2026-11-18T13:39:14.966Z",
+ "url": "https://openreview.net/forum?id=W44dmCYl89&noteId=xc29mBd6NK",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/w44dmcyl89/submission.json added

+++ b/reviews/openreview/w44dmcyl89/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "W44dmCYl89",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 14108,
+ "url": "https://openreview.net/forum?id=W44dmCYl89",
+ "license": "CC-BY-4.0"
+}

versions/v_i68wv4gb.json added

+++ b/versions/v_i68wv4gb.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-05-02",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 14108,
+ "url": "https://openreview.net/forum?id=W44dmCYl89",
+ "reviews": "openreview/w44dmcyl89",
+ "evidence": [
+ "https://openreview.net/forum?id=W44dmCYl89"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=W44dmCYl89",
+ "evidence": [
+ "https://openreview.net/forum?id=W44dmCYl89"
+ ]
+}