potentialpaper

DeepArrhythmia: Segment-Contextualized ECG Arrhythmia Classification via Selective Evidence Acquisition

Import NeurIPS 2026 submission i8JkJYOjY6: 10 notes

@openreview[bot] · 2026-11-22 17:58 UTC · 598dd372a03a

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,26 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "i8JkJYOjY6"
+ }
+ ],
+ "title": "DeepArrhythmia: Segment-Contextualized ECG Arrhythmia Classification via Selective Evidence Acquisition",
+ "authors": [
+ "Jiahui Li",
+ "Ruili Fang",
+ "Zishuai Liu",
+ "WenZhan Song",
+ "Jin Lu",
+ "Fei Dou"
+ ],
+ "abstract": "Beat-level Electrocardiography (ECG) arrhythmia detection aims to assign an arrhythmia class to each beat in a recording, yet many existing systems treat beats as isolated local instances. This is limiting because beat labels often depend on multi-beat rhythm context, including timing, compensatory pauses, and beat-to-beat morphological consistency. We present $\\textbf{DeepArrhythmia}$, a tool-grounded multimodal framework for segment-contextualized beat-level ECG arrhythmia classification. Given a multi-beat ECG segment, DeepArrhythmia combines the raw ECG signal and a rendered waveform image, localizes R peaks to identify beat instances, and produces structured beat-level predictions. The framework decouples physiological measurement from evidence integration using specialized tools for beat localization, numerical rhythm--morphology extraction, and morphology-focused textual analysis. DeepArrhythmia uses segment-level confidence to route between minimal and rich evidence states, since richer physiological evidence is not uniformly useful. This agentic design integrates rhythm context, explicit physiological grounding, and selective evidence acquisition for decision making.",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/i8jkjyojy6/forms.json added

+++ b/reviews/openreview/i8jkjyojy6/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/i8jkjyojy6/notes/f1cnfgcvpi.json added

+++ b/reviews/openreview/i8jkjyojy6/notes/f1cnfgcvpi.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "F1cNFGcVPi",
+ "replyTo": "MymHBjW7ha",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We thank the reviewer for these constructive suggestions. All four points are now supported by new experiments, and we clarify one item that we believe was missed in the appendix.\n\n**W1 / Q1 — Robustness to noise, and performance at a less-optimal threshold.**\n\nWe add a signal-noise study: additive Gaussian noise and baseline wander are injected into the raw signal at 24/18/12/6 dB, and the corrupted signal is propagated through the whole pipeline (re-encoded, image re-rendered, morphology features re-extracted). Degradation is graceful, never a collapse: baseline wander is almost fully absorbed (Micro-F1 0.848 → 0.843 at 6 dB), and Gaussian noise leaves accuracy essentially unchanged down to 12 dB, with only a −2.8 pt Micro-F1 drop at the extreme 6 dB. The loss concentrates on morphology-dependent classes (V 0.848 → 0.755 at 6 dB) while the rhythm-anchored N class stays stable (0.916 → 0.899), consistent with noise corrupting morphological evidence but not the RR/peak anchors.\n\nOn the threshold, performance sits on a wide plateau rather than a narrow optimum. Since segment confidence concentrates near 1, all routing occurs in τ ∈ [0.98, 1.0]; sweeping that entire range changes Micro-F1 by at most 1.4 points (MIT-BIH 0.9498–0.9524, MIT-BIH-SUP 0.9509–0.9530, INCART 0.9746–0.9807, VitalDB 0.9116–0.9255), with the endpoints reproducing the Minimal- and Rich-specialization rows of Table 1 and no discontinuity in between. A clearly mis-specified threshold therefore costs a fraction of a point, not a failure. Noise also pushes routing in the safe direction: it lowers confidence, so a fixed threshold acquires rich evidence more often exactly when the input is degraded.\n\n**W2 / Q2 — The fixed 10-second window and boundary beats; sliding window / agent memory.**\n\nWe agree this is the right test of our own motivation, and we now quantify it. Boundary beats (first/last in a window) are only marginally harder overall — Micro-F1 0.9435 vs 0.9521 for interior beats, with the dominant N class essentially unaffected (0.970 vs 0.975) — and the gap is confined to the abnormal classes that depend on surrounding context. We then re-classify each abnormal boundary beat inside a window re-centered on it, which emulates overlapping (sliding-window) inference:\n\n| Beat position | Acc. | Macro-F1 | S | V | F |\n| --- | --- | --- | --- | --- | --- |\n| Boundary (original) | 0.606 | 0.466 | 0.445 | 0.915 | 0.038 |\n| Interior (reference) | 0.683 | 0.507 | 0.490 | 0.961 | 0.072 |\n| Re-centered (sliding) | **0.694** | **0.584** | **0.531** | **0.966** | **0.254** |\n\nRe-centering recovers the gap and matches interior-beat performance (+8.9 pt accuracy, +11.8 pt Macro-F1; 131 of 867 beats corrected vs 54 regressed), with the largest gain on the context-dependent fusion class (0.038 → 0.254). We used non-overlapping windows in the main results for training and inference efficiency (overlap multiplies compute per beat) and because the shift-based re-anchoring augmentation already keeps the boundary deficit small; the result above shows overlapping inference is a cheap and effective remedy for the residual gap, which we now state explicitly.\n\n**W3 — Cross-dataset evaluation.**\n\nWe would like to clarify that the submission does include a full 4×4 cross-dataset evaluation (Appendix I): every dataset's model is evaluated on every other dataset's test split. In-domain Micro-F1 is 0.95–0.98, transfer among MIT-BIH, MIT-BIH-SUP, and INCART is strong (e.g., MIT-BIH-SUP → INCART 0.871, INCART → MIT-BIH 0.924), and the gap concentrates on transfers involving VitalDB (MIT-BIH → VitalDB 0.551; VitalDB → MIT-BIH-SUP 0.094), which differs most in acquisition device, lead configuration, and sampling rate.\n\nFollowing this concern we additionally ran the identical protocol on two baselines. Averaged over the twelve off-diagonal transfers, DeepArrhythmia degrades far less (mean Micro-F1 0.70) than the 1D ResNet (0.46), and the feature-based SVM systematically collapses to majority-class (normal) prediction off-diagonal, losing all abnormal-beat detection (Macro-F1 0.65 → 0.29). Limited cross-dataset transfer is therefore a property of the domain shift shared by all beat-level methods rather than an artifact of four separately-fit models, and our framework is the most robust of the three. Because its decisions are grounded in explicit peak, rhythm, and morphology evidence, its transfer failures are also inspectable, unlike those of the baselines.\n\n**Q3 — Synthetic data for the rare classes.**\n\nWe already perform data-level synthesis for rare classes: the shift-based re-anchoring augmentation resamples each non-normal class toward the majority count, synthesizing many within-window position variants of S/V/F beats. Its ablation confirms it is critical — removing it drops MIT-BIH Micro-F1 from 0.9501 to 0.9120, with the loss concentrated on minority classes (Table 2). For fusion beats specifically, the bottleneck is not only scarcity but morphological ambiguity: F is a variable blend of a normal and a ventricular complex, and the confusion matrix shows F collapsing to N (91%) rather than being confused among abnormal classes, so position-based or naive oversampling has limited headroom. Generative synthesis of realistic fusion morphology (e.g., diffusion-based waveform generation) is a promising direction we now note as future work."
+ },
+ "createdAt": "2026-07-24T23:57:04.753Z",
+ "modifiedAt": "2026-11-18T17:16:56.893Z",
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6&noteId=F1cNFGcVPi",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/i8jkjyojy6/notes/fw1hv2kcc2.json added

+++ b/reviews/openreview/i8jkjyojy6/notes/fw1hv2kcc2.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "FW1hV2kcc2",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer QwMt",
+ "content": {
+ "summary": "The authors present DeepArrhythmia. DeepArrhythmia improves beat-level arrhythmia classification by predicting each R-peak-aligned beat inside a longer ECG segment instead of looking at isolated beat crops. This lets the model use both the shape of the beat itself and the surrounding rhythm context. It also uses agents with tools to extract useful evidence, such as detected peaks, rhythm measurements, morphology measurements, and short textual descriptions, making the prediction process easier to interpret. Finally, it does not use all extra evidence for every case; instead, it uses confidence to decide when more evidence is needed, helping difficult cases while avoiding unnecessary noise or cost for easier ones.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths\n- The authors address an important problem in utilizing AI for arrhythmia detection. \n- DeepArrhythmia is a novel framework that provides interpretability by using the outputs from multiple modular tools to ground its final prediction.\n- The method is technically sound and validated with comprehensive experiments.\n- The figure and paper is easy to follow.\n- The experiments on augmented and perturbations of the data are well appreciated.\n\nWeaknesses\n- As the authors have acknowledged, the pipeline seems to be heavily influenced by the data: 1) has poor cross-dataset generalization and 2) poor generalization to rare classes. A question I have here then is how does DeepArrhythmia compare in these 2 limitations with other baselines? It would be important to see this comparison.\n- The pipeline seems to be quite expensive and hand-engineered, compared to other baselines such as SVM, which are much simpler and competitive in performance.\n- I am curious on how the performance of DeepArrhythmia compares to other baseline models under balanced class distributions for both training and testing. This would give more insight on DeepArrhythmia's performance compared to other baselines.\n- As the performances are not overwhelmingly better than previous baselines as well as quite volatile across each dataset, it would be important to see the statistical significance of the results.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 4,
+ "originality": 3,
+ "questions": "- For the faithfulness evaluation (Appendix M), what was the dataset and the distribution used to conduct the experiment?\n- Why have the authors not tried on perhaps two of the most famous ECG datasets, PTB-XL and MIMIC-IV ECG? I would hope to see performances on at least PTB-XL, as MIMIC-IV ECG is quite large. I am curious on why the authors chose not to include these two datasets.",
+ "limitations": "yes",
+ "rating": 5,
+ "confidence": 5,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "na",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The authors have sufficiently added relevant experiments and answered my questions. I have adjusted my review accordingly."
+ },
+ "createdAt": "2026-06-22T23:52:22.020Z",
+ "modifiedAt": "2026-11-18T13:39:47.148Z",
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6&noteId=FW1hV2kcc2",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/i8jkjyojy6/notes/ltsynsvyhy.json added

+++ b/reviews/openreview/i8jkjyojy6/notes/ltsynsvyhy.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "lTSYNSvYHY",
+ "replyTo": "xJU5hEX1Pp",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "**L1 — Novelty is mostly system integration.**\n\nWe agree and have revised the framing. We do not claim a new primitive; our contribution is the reformulation of beat-level classification as segment-contextualized, peak-aligned prediction, plus the confidence-gated acquisition policy — the one new mechanism, deciding *when* evidence is worth acquiring rather than applying every tool uniformly. Language suggesting an algorithmic breakthrough has been removed.\n\n**L2 — The Morphology Analyzer may inherit priors from the label-conditioned teacher.**\n\nSee Q4: distillation is split-safe (training subjects only), no label is given at inference, and the output is morphology text rather than a class token. The evidence-deletion test (Table 13) shows predictions depend causally on the cited cue (accuracy 92.5% → 1.9% when it is disrupted). And even if some prior were inherited, it is not carrying the result — removing the analyzer entirely still beats every baseline (Q5).\n\n**L3 — Fairness of comparison with VLM baselines.**\n\nTwo existing controls address this in both directions. The matched non-agentic fusion baseline receives the full evidence set *including morphology* and still underperforms (Macro/Micro-F1 0.567/0.937 vs 0.593/0.950). Conversely, restricted to exactly the evidence the VLM baselines receive, DeepArrhythmia still exceeds all of them (0.5694 vs SVM 0.523, Gemini-3.1 0.410; Q5). The advantage therefore does not rest on dataset-specific tool specialization; we will make both controls more prominent.\n\n**L4 — The routing policy is simple and confidence may be poorly calibrated.**\n\nThe simplicity is deliberate and competitive. Confidence is well calibrated in-domain (ECE 0.058/0.029/0.024/0.042; Q3), and against a stochastic entropy router and a *learned* router the simple threshold matches or exceeds both (Macro-F1 MIT-BIH 0.593 vs 0.592/0.586; INCART 0.629 vs 0.628/0.622; VitalDB 0.892 vs 0.886/0.894). Under noise it also fails safe: lower confidence means more evidence is acquired. We agree calibration need not transfer across devices, and note uncertainty-aware or conformal routing as the next step.\n\n**L5 — Threshold selection may overfit the validation distribution.**\n\nτ is selected on a held-out route-induction split from training subjects only and fixed before test-time evaluation, so it never sees the test distribution. More importantly its precision barely matters: over the entire operative range τ ∈ [0.98, 1.0], Micro-F1 varies by ≤1.4 points with no discontinuity (Q6), so a transferred or mis-set threshold costs a fraction of a point rather than failing. Validation across hospitals is not demonstrated here; label-free threshold setting (a fixed confidence percentile) and multi-center validation are future work.\n\n**Q1. How robust is DeepArrhythmia to R-peak detection errors (missed / mislocalized / extra anchors)?**\n\nWe now cover all three detector failure modes. Missed (masking) and mislocalized (6–30-sample shift) were in Table 14; the revision adds extra/spurious peaks. Class-wise collateral ΔF1 (F1_clean − F1_stress):\n\n| Class | Mask | Mislocalize | Extra |\n| --- | --- | --- | --- |\n| N | 0.004 | 0.014 | 0.028 |\n| S | 0.019 | 0.136 | **0.302** |\n| V | 0.043 | 0.025 | 0.072 |\n| F | 0.056 | 0.033 | 0.050 |\n\nDegradation is graceful and concentrated on the timing-dependent S class; N stays stable. Spurious anchors (no ground-truth beat) are labelled N only 34.6% of the time and arrhythmic 63.4%, i.e., false detections are not robustly rejected — motivating tighter detector–classifier coupling.\n\n**Q2. How often is the rich-evidence path selected, and how does it correlate with difficulty, noise, or arrhythmia class?**\n\nUsing each dataset's threshold (C_seg < τ_d):\n\n| Dataset | Rich (all) | Normal-only | Abnormal |\n| --- | --- | --- | --- |\n| MIT-BIH | 47.4% | 32.2% | 72.0% |\n| MIT-BIH-SUP | 43.4% | 17.3% | 70.0% |\n| INCART | 31.3% | 9.1% | 48.1% |\n| VitalDB | 17.1% | 8.2% | 27.4% |\n\n**Class:** arrhythmia-containing segments trigger the rich path 2.2–5.3× more than normal-only. **Difficulty:** rich concentrates on the lowest-confidence quartile, where the minimal model is least accurate (0.81–0.91 vs 0.97–1.00). **Datasets:** lowest on VitalDB, where rich evidence is least helpful — the router correctly acquires it least where it does not help. **Noise:** not routed directly, but noise lowers confidence, so the mechanism would acquire rich more often.\n\n**Q3. How well calibrated are the routing confidence scores (ECE / reliability / domain shift)?**\n\nThe segment confidence (mean per-beat max-softmax) is well calibrated in-domain: ECE = 0.058 (MIT-BIH), 0.029 (SUP), 0.024 (INCART), 0.042 (VitalDB). Binned accuracy tracks confidence closely (mild mid-range under-confidence, slight over-confidence near 1.0), consistent with Fig. 6 (confidence vs Micro-F1). Under cross-dataset shift accuracy drops and calibration is not guaranteed to transfer, which is why we re-select the threshold per dataset rather than using a single global scale.\n\n**Q4. Since the Morphology Analyzer is trained with label-conditioned distillation, how do you ensure it gives morphology rather than implicit label leakage?**\n\nBy design: distillation is split-safe (training subjects only, subject-disjoint from test); no ground-truth label at inference; the output is textual morphology (QRS width, P-wave, RR regularity), not a class token. Empirically, the faithfulness / evidence-deletion test (Table 13) rules out leakage: disrupting the exact cue an explanation cites collapses accuracy to 1.88% overall vs 92.50% for control perturbations of unrelated regions (QRS 1.9/96.2, P-wave 1.9/90.7, RR 1.9/90.6). Cardiologists also rate the label-free analyses as clinically valid morphology (Table 4).\n\n**Q5. Would the method still beat baselines with the Morphology Analyzer removed (numerical features only)?**\n\nYes — this is the \"w/o Morphology Analyzer\" ablation (Table 2), retaining signal, image, peaks, and numerical features. On MIT-BIH it reaches Macro-F1 0.5694 / Micro-F1 0.9433, still above every external baseline (SVM 0.523/0.934; best deep xECG/TCN ≈0.44/0.89; best VLM Gemini 0.410/0.878). The Morphology Analyzer adds a further +2.4 Macro-F1 (→0.5929) — a complementary boost, not the source of the edge.\n\n**Q6. How sensitive is performance to the routing threshold — plateau or narrow optimum?**\n\nA wide plateau. Confidence concentrates near 1, so all routing occurs in τ ∈ [0.98, 1.0]; over this whole range Micro-F1 varies ≤1.4 pt: MIT-BIH 0.9498–0.9524, SUP 0.9509–0.9530, INCART 0.9746–0.9807, VitalDB 0.9116–0.9255. Endpoints reproduce the Minimal- and Rich-specialization rows of Table 1, with no discontinuity, so a mis-set threshold costs at most a fraction of a point rather than collapsing.\n\n**Q7. Can you provide per-class F1 for S, V, and F?**\n\nReported per-dataset in Table 12 (with precision/recall and the SVM reference); DeepArrhythmia F1:\n\n| Dataset | N | S | V | F |\n| --- | --- | --- | --- | --- |\n| MIT-BIH | 0.974 | 0.392 | 0.940 | 0.066 |\n| MIT-BIH-SUP | 0.981 | 0.673 | 0.804 | – |\n| INCART | 0.991 | 0.812 | 0.937 | 0.099 |\n| VitalDB | 0.940 | 0.853 | 0.783 | – |\n\n(\"–\": <5 beats.) V is robust (0.78–0.94); S is dataset-dependent (0.392–0.853); F is hardest (rarity + morphological heterogeneity).\n\n**Q8. What are the most common failure modes on fusion (F) and supraventricular (S) beats?**\n\nBoth collapse toward N (Fig. 7). **S→N:** 1151/1833 (63%; 33% correct) — S preserves a near-normal QRS and is distinguished mainly by timing/P-wave, a subtle cue. **F→N:** 353/388 (91%; 5%→V) — a fusion beat is a normal⊕ventricular blend, so under uncertainty it collapses to the dominant N (occasionally its ventricular parent V). Errors are misses toward N, not confusion among abnormal classes — consistent with the class imbalance and these beats' reliance on context.\n\n**Q9. How does DeepArrhythmia perform cross-dataset, and what causes the generalization gap?**\n\nWe report a full 4×4 matrix (Table 11): in-domain Micro-F1 0.95–0.98, strong transfer among MIT-BIH/SUP/INCART (e.g., SUP→INCART 0.871), the gap concentrated on VitalDB (MIT-BIH→VitalDB 0.551; VitalDB→SUP 0.094). Causes are acquisition/population shift, not the framework: differing sampling rates and leads (360 Hz MLII/V5 vs 257 Hz vs a different monitor), differing class priors, and VitalDB's markedly different acquisition. The gap is shared by all methods and DeepArrhythmia degrades least: over the 12 off-diagonal transfers its mean Micro-F1 is 0.70 vs 0.46 for the 1D ResNet, while the SVM collapses to majority-class off-diagonal (Macro-F1 0.65→0.29).\n\n**Q10. Is the system intended for offline Holter analysis, bedside monitoring, or real-time detection?**\n\nDeepArrhythmia targets offline / retrospective analysis and clinical decision support (Holter review, second-read of flagged segments), where beat-level accuracy and auditable interpretability matter; as an LLM-with-tools agent it is not intended for hard real-time on-device alarming (cost/latency in Table 3). Confidence-guided routing invokes the expensive tools only on low-confidence segments, keeping batch throughput efficient; at the bedside it is best used"
+ },
+ "createdAt": "2026-07-24T23:11:36.256Z",
+ "modifiedAt": "2026-11-18T17:16:55.124Z",
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6&noteId=lTSYNSvYHY",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/i8jkjyojy6/notes/mymhbjw7ha.json added

+++ b/reviews/openreview/i8jkjyojy6/notes/mymhbjw7ha.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "MymHBjW7ha",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer 9zQP",
+ "content": {
+ "summary": "This paper introduces an agentic frame work for beat-level ECG arrhythmia classification. It is able to route based on confidence values from an upstream model to dynamically call tools to get more evidence and make better predictions. The results are strong on 4 public datasets, across performance and cost.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths:\nThe paper proposes a reasonable agent framework to address some limitations of existing methods. The paper considers computation cost and proposes a well-thought-out and effective routing mechanism. \nThe ablations are also great for showing how much each piece of evidence contributes to the final result.\nI appreciate the non-agentic baseline comparison. This makes the contribution more convincing.\n\n\nWeaknesses:\nThe tools suffer from a lack of robustness to noise and boundary cutoffs. The method uses a fixed 10-second window, but the whole motivation of the paper (Figure 1) is that you need surrounding rhythm context to classify beats correctly. \nThere's also no cross-dataset evaluation. Four datasets are used, but each one is trained and tested separately. there's no experiment checking whether a model trained on one dataset actually transfers to another. That makes it hard to tell if this is one generalizable method or four separately-fit models that happen to work well on their own data.\nThe threshold used for routing needs to be decided for each dataset. How important is this threshold? I often find it unrealistic for real-world use to expect confidence thresholds to hold up. This is mentioned in the limitations, but I think some simple evidence that the framework still provides good performance at a less optimal threshold can help practitioners.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "Is the routing threshold robust to noise? Can you showcase the framework performance on a less optimal threshold? Maybe \n\nIs there a way to address the boundary issue? Maybe via agent memory or a sliding window approach? What are the reasons for not doing this?\n\nIs it possible to generate synthetic data for the rarer cases that the model performs poorly on?",
+ "limitations": "yes",
+ "rating": 5,
+ "confidence": 2,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "N/A",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The authors have addressed most of my concerns."
+ },
+ "createdAt": "2026-06-26T10:21:35.136Z",
+ "modifiedAt": "2026-11-18T13:39:43.882Z",
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6&noteId=MymHBjW7ha",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/i8jkjyojy6/notes/nle3xkwntb.json added

+++ b/reviews/openreview/i8jkjyojy6/notes/nle3xkwntb.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "nlE3xkwNtb",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "Four knowledgeable reviewers evaluated this paper, yielding two accept and two borderline accept recommendations. The reviewers are generally positive, viewing the noted weaknesses as addressable limitations rather than barriers to publication. They agree that the paper tackles a clinically meaningful problem with a sound framework, strong motivation, and a thorough empirical evaluation.\n\nKey strengths include a clinically motivated setup treating beat-level arrhythmia classification as a segment-contextualized prediction problem, and an interpretable architecture that decouples physiological measurement from evidence integration. Reviewers also praised the confidence-guided evidence acquisition mechanism for its computational efficiency, alongside comprehensive experiments featuring solid ablations and clear comparisons against non-agentic baselines.\n\nWhile the reviewers noted that the technical novelty stems from integrating existing components rather than introducing a radically new algorithm, they found this to be an acceptable contribution. However, the authors must address specific technical concerns regarding robustness to peak-detection errors and noise, the calibration and threshold stability of the routing mechanism, cross-dataset transfer performance, and the exact role of the Morphology Analyzer.\n\nThe author response should focus heavily on these robustness and generalization questions, particularly routing calibration and cross-dataset behavior. Satisfactory clarifications on these points will keep this paper on its positive trajectory toward acceptance.\n\nNote to Authors: The paper 'A real-time QRS detection algorithm' by Jiapu Pan and Willis J. Tompkins is a seminal paper published in IEEE Transactions on Biomedical Engineering in 1985 (Volume BME-32, Issue 3, pages 230–236). The citation incorrectly lists the publication year as 2007 and the volume as 54. Please fix the discrepancy.",
+ "final_justification": "The authors addressed the key concerns raised during review through additional experiments and clarifications. The rebuttal improved confidence in the robustness of the Morphology Analyzer, the fairness of the VLM comparisons, and the stability of the confidence-guided routing mechanism. My original reservation remains: the primary contribution is an effective integration of existing components rather than a fundamentally new algorithmic advance. However, the work is technically sound overall, practically relevant, and supported by a sufficient empirical evaluation."
+ },
+ "createdAt": "2026-09-24T11:21:01.771Z",
+ "modifiedAt": "2026-11-18T14:55:16.138Z",
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6&noteId=nlE3xkwNtb",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/i8jkjyojy6/notes/o53a1uqhbu.json added

+++ b/reviews/openreview/i8jkjyojy6/notes/o53a1uqhbu.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "o53a1uqhbU",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair UboE",
+ "content": {
+ "metareview": "Four knowledgeable reviewers evaluated this paper, yielding two accept and two borderline accept recommendations. The reviewers are generally positive, viewing the noted weaknesses as addressable limitations rather than barriers to publication. They agree that the paper tackles a clinically meaningful problem with a sound framework, strong motivation, and a thorough empirical evaluation.\n\nKey strengths include a clinically motivated setup treating beat-level arrhythmia classification as a segment-contextualized prediction problem, and an interpretable architecture that decouples physiological measurement from evidence integration. Reviewers also praised the confidence-guided evidence acquisition mechanism for its computational efficiency, alongside comprehensive experiments featuring solid ablations and clear comparisons against non-agentic baselines.\n\nWhile the reviewers noted that the technical novelty stems from integrating existing components rather than introducing a radically new algorithm, they found this to be an acceptable contribution. However, the authors must address specific technical concerns regarding robustness to peak-detection errors and noise, the calibration and threshold stability of the routing mechanism, cross-dataset transfer performance, and the exact role of the Morphology Analyzer.\n\nThe author response should focus heavily on these robustness and generalization questions, particularly routing calibration and cross-dataset behavior. Satisfactory clarifications on these points will keep this paper on its positive trajectory toward acceptance.\n\nNote to Authors: The paper 'A real-time QRS detection algorithm' by Jiapu Pan and Willis J. Tompkins is a seminal paper published in IEEE Transactions on Biomedical Engineering in 1985 (Volume BME-32, Issue 3, pages 230–236). The citation incorrectly lists the publication year as 2007 and the volume as 54. Please fix the discrepancy."
+ },
+ "createdAt": "2026-07-20T21:17:24.403Z",
+ "modifiedAt": "2026-11-18T15:21:37.036Z",
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6&noteId=o53a1uqhbU",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/i8jkjyojy6/notes/q5xkqtcxzh.json added

+++ b/reviews/openreview/i8jkjyojy6/notes/q5xkqtcxzh.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "q5xkQtcxZh",
+ "replyTo": "VffhuOyVVo",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "**L — No evaluation of performance degradation under added noise.**\n\nWe agree this was missing and have added a signal-level noise study. Gaussian noise and baseline wander are injected into the raw signal at 24/18/12/6 dB, and each corrupted signal is propagated through the *entire* input pipeline — re-encoded by the ECG-CoCa encoder, the waveform image re-rendered from it, and the amplitude/HOS/myMorph features re-extracted from it — so no modality retains a clean copy. R-peaks are held fixed to isolate signal quality from peak-detection error (studied separately).\n\nDegradation is graceful and never a collapse. Baseline wander is almost entirely absorbed: at 6 dB Micro-F1 falls only from 0.848 to 0.843 and Macro-F1 from 0.561 to 0.541, since median-filter baseline removal suppresses low-frequency drift while morphology is preserved. Gaussian noise is harsher but well tolerated down to 12 dB (within one Micro-F1 point of clean), with a clear decline only at the extreme 6 dB level (Micro-F1 −2.8, Macro-F1 −7.4 points). The loss is concentrated on morphology-dependent classes — V-class F1 drops 0.848 → 0.755 at Gaussian 6 dB and the minority S/F classes decline — while the rhythm-anchored N class stays stable (0.916 → 0.899), consistent with noise corrupting morphological evidence but not the RR/peak anchors. Full tables and SNR curves are added to the revised appendix.\n\n**Q1. The rendered image is derived from the raw signal and carries no independent information — what explains the accuracy gain from adding the image modality?**\n\nThe reviewer is right that the image is information-theoretically redundant; its benefit is a complementary *representation* rather than new information. Rendering the 1-D signal as a 2-D waveform lets a pretrained vision encoder apply spatial inductive biases (local receptive fields, translation invariance) that are well matched to reading QRS shape and P-wave morphology, whereas our numerical features summarize the signal into scalar descriptors that can under-express these subtle cues. Removing the image lowers MIT-BIH Macro-F1 from 0.5929 to 0.5394 (Table 2).\n\nA per-beat analysis of where the image helps makes this concrete. The beats the image recovers are overwhelmingly **abnormal beats that the numerical-only model misclassifies as normal** — chiefly supraventricular (S) beats: 138 of the 143 recovered S beats were labelled N without the image. These are premature beats (normalized pre-RR ≈ 0.71) with a near-normal QRS, so the RR timing feature alone is insufficient to separate them from normal, and the rendered waveform supplies the complementary morphological view (P-wave presence and subtle QRS shape) needed to tip the decision. In other words, the image does not add information but exposes, through a spatial representation and vision priors, morphology that the scalar features compress away — precisely the cases (near-normal S beats) where our motivation (morphology-in-context) is most binding.\n\n**Q2. Would longer segments than 10 s further improve performance?**\n\nYes, within limits — this is our context-length ablation (Appendix N / Fig. 8a). Increasing the window from 1,800 samples (5 s) to 3,600 (10 s) raises Macro-F1 from 0.5924 to 0.5929 and Micro-F1 from 0.9403 to 0.9501, and extending to 5,000 samples improves them further to 0.6235 / 0.9512, confirming that longer rhythm context helps, especially for class-balanced (Macro) performance. The 10-second window is a practical operating point (clinical convention, bounded model context and compute), but the trend indicates that additional context yields further, gradually diminishing gains.\n\n**Q3. Which components transfer to non-ECG biosignals, and for what tasks?**\n\nMost of the framework is signal-agnostic. The peak detector, the numerical rhythm/morphology feature extractor, and the image-based morphology analyzer all operate on the generic notion of fiducial points and their local context, and thus transfer directly to other quasi-periodic signals — systolic peaks in PPG, J-peaks in BCG, pulse onsets in arterial blood pressure. The confidence-guided selective evidence acquisition is a task-agnostic meta-strategy applicable whenever auxiliary evidence has non-uniform utility. Only the ECG-CoCa encoder is modality-specific, occupying a generic slot that can be swapped for a PPG/BCG/EEG encoder. The approach is therefore well suited to event- or beat-level classification on pulsatile signals — e.g., PPG-based arrhythmia/AF screening, BCG cardiac monitoring, and sleep/apnea or stress inference — particularly where precise event localization, heterogeneous evidence quality, and interpretability all matter."
+ },
+ "createdAt": "2026-07-25T00:06:11.691Z",
+ "modifiedAt": "2026-11-18T17:16:54.866Z",
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6&noteId=q5xkQtcxZh",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/i8jkjyojy6/notes/vffhuoyvvo.json added

+++ b/reviews/openreview/i8jkjyojy6/notes/vffhuoyvvo.json
@@ -0,0 +1,31 @@
+{
+ "schema": "review/1",
+ "id": "VffhuOyVVo",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer tYLh",
+ "content": {
+ "summary": "This paper proposes DeepArrhythmia, a novel integrated framework for beat-level ECG arrhythmia classification that incorporates multi-beat rhythm context. By combining multiple sources of evidence—raw waveforms, rendered images, numerical features, and textual explanations—it leverages additional information for challenging cases. None of these components represents a breakthrough innovation on its own, but each is thoughtfully adapted to the ECG domain and together they contribute steady, incremental accuracy improvements, as demonstrated by the careful and comprehensive experimental results. Evaluation on four ECG datasets under subject-disjoint splits demonstrates consistent improvement over conventional ML, deep learning, and VLM baselines.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "None of the proposed components represents a breakthrough innovation on its own, but each is thoughtfully adapted to the ECG domain and together they contribute steady, incremental accuracy improvements, as demonstrated by the careful and comprehensive experimental results. Evaluation on four ECG datasets under subject-disjoint splits demonstrates consistent improvement over conventional ML, deep learning, and VLM baselines. \n\nThe experimental evaluation is comprehensive and methodologically rigorous. The ablation study clearly demonstrates the extent to which each component contributes to performance improvement.",
+ "quality": 3,
+ "clarity": 4,
+ "significance": 4,
+ "originality": 3,
+ "questions": "1. The rendered ECG image is derived from the raw time-series signal and therefore carries no independent information. Nevertheless, what might explain the observed minor improvement in accuracy when the image modality is included as an input?\n2. The use of a 10-second segment length appears to be motivated by practical or operational constraints, but if it were possible to use even longer segments, would classification performance further improve? \n3. Which components of the proposed framework could be applied to physiological signals other than ECG? For what types of biosignal processing tasks might this approach provide similar benefits?",
+ "limitations": "The authors discuss limitations in Section 5 and Appendix T. In particular, robustness to noise is practically important, but the paper does not include any evaluation of performance degradation caused by the addition of noise.",
+ "rating": 5,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No issues identified.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes"
+ },
+ "createdAt": "2026-06-23T08:14:05.886Z",
+ "modifiedAt": "2026-11-18T13:39:45.711Z",
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6&noteId=VffhuOyVVo",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/i8jkjyojy6/notes/xabh41ub8s.json added

+++ b/reviews/openreview/i8jkjyojy6/notes/xabh41ub8s.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "xaBh41ub8S",
+ "replyTo": "FW1hV2kcc2",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "**W1 — Comparison with baselines on cross-dataset and rare-class generalization.**\n\nWe add both comparisons under an identical protocol. Cross-dataset: averaged over the 12 off-diagonal train/test transfers, DeepArrhythmia degrades far less than the baselines (mean Micro-F1 0.70 vs 0.46 for the 1D ResNet). Its failure mode also differs from the SVM's: the SVM systematically collapses to the majority (normal) class off-diagonal, losing all abnormal-beat detection (Macro-F1 0.65 → 0.29), whereas DeepArrhythmia retains abnormal detection on most transfers; its worst case is confined to the VitalDB-trained direction (the most dissimilar acquisition), where it over-predicts a single abnormal class — the same VitalDB outlier degrades all methods. Rare classes: per-class F1 (Table 12) shows DeepArrhythmia is highest on every abnormal class on MIT-BIH (S 0.392 vs SVM 0.206 vs ResNet 0.073; F 0.066 vs 0.025 vs 0.040). Crucially, because DeepArrhythmia grounds each decision in explicit peak, rhythm, and morphology evidence, these failures are diagnosable — one can inspect the numerical features and textual morphology behind a wrong prediction — whereas the SVM and ResNet offer no such insight.\n\n**W2 — Cost / hand-engineering vs. a simple SVM.**\n\nThe SVM is simpler and in-domain competitive, but it is a black box that does not generalize: it collapses to majority-class prediction under cross-dataset shift (see W1) and, by construction, produces only a class label with no supporting evidence. DeepArrhythmia's additional cost buys three things a simple classifier cannot provide. (i) Interpretability: every prediction is grounded in explicit, auditable evidence — detected peaks, numerical rhythm/morphology measurements, and a textual morphology analysis — and this evidence is verified to be causally used, not decorative: an evidence-deletion test (Table 13) shows that disrupting the exact cue an explanation cites collapses accuracy from 92.5% to 1.9%, and cardiologists rate the analyses as clinically valid (Table 4). This auditability is essential for a clinical decision-support setting and makes even error cases inspectable. (ii) Better cross-dataset robustness (W1). (iii) Efficiency via confidence-guided routing, which invokes the expensive tools on only a minority of segments. We also note the method's accuracy does not depend on the heaviest component: even without the Morphology Analyzer (numerical features only), DeepArrhythmia already exceeds the SVM (Macro-F1 0.5694 vs 0.523).\n\n**W3 — Performance under a balanced class distribution.**\n\nMacro-F1, our primary metric, already weights all classes equally. Adding a balanced metric (balanced accuracy = mean per-class recall) on MIT-BIH gives DeepArrhythmia 0.568 vs SVM 0.516 vs 1D ResNet 0.449, so the ordering is preserved under class-balanced evaluation. (Balanced re-training would require retraining all models; we are happy to add it if preferred.)\n\n**W4 — Statistical significance.**\n\nWe add 95% bootstrap confidence intervals on MIT-BIH Macro-F1: DeepArrhythmia 0.593 [0.583, 0.603], SVM 0.523 [0.516, 0.530], 1D ResNet 0.362 [0.356, 0.367]. The intervals are non-overlapping, so DeepArrhythmia's improvement is statistically significant; the ML/DL baselines in Table 1 are additionally averaged over three seeds.\n\n**Q1 — Dataset/distribution used for the faithfulness evaluation (Appendix M).**\n\nThe evidence-deletion test (Table 13) is conducted on the MIT-BIH test set, on 160 beats whose explanations cite a specific morphological cue, stratified by cue type (QRS 53, P-wave 54, RR 53). We will state this explicitly in the revision.\n\n**Q2 — Why not PTB-XL and MIMIC-IV ECG?**\n\nThese are excellent resources but target a different task: they provide record-level, 12-lead diagnostic-statement labels, not the per-beat AAMI (N/S/V/F) annotations required for beat-level arrhythmia classification. The four datasets we use were chosen precisely because they carry beat-level annotations under subject-disjoint splits. The framework's components do transfer to record-level 12-lead classification (we apply them to PTB-XL superclasses in related work), but that is outside the beat-level scope of this paper."
+ },
+ "createdAt": "2026-07-25T00:19:42.103Z",
+ "modifiedAt": "2026-11-18T17:16:55.124Z",
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6&noteId=xaBh41ub8S",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/i8jkjyojy6/notes/xju5hex1pp.json added

+++ b/reviews/openreview/i8jkjyojy6/notes/xju5hex1pp.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "xJU5hEX1Pp",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer M61L",
+ "content": {
+ "summary": "This paper proposes DeepArrhythmia, a tool-grounded multimodal framework for beat-level ECG arrhythmia classification. The key idea is that beat-level arrhythmia classification should not be treated as isolated beat classification, because labels such as supraventricular ectopic beats and ventricular ectopic beats often require multi-beat rhythm context, compensatory pauses, and beat-to-beat morphology consistency.\n\nDeepArrhythmia processes a 10-second ECG segment using both raw ECG signals and rendered ECG waveform images. It first uses a Peak Detector to localize R peaks and define beat anchors. Then, under a minimal evidence state, the model predicts beat-level labels using the signal, image, and detected beat anchors. If the segment-level confidence is below a dataset-specific threshold, the model selectively invokes additional tools: a Feature Extractor for numerical rhythm–morphology measurements and a Morphology Analyzer for textual morphology evidence. The final output is a structured peak-aligned sequence of beat labels under the AAMI label set {N, S, V, F}.\nThe method is evaluated on MIT-BIH Arrhythmia, MIT-BIH Supraventricular, INCART, and VitalDB Arrhythmia datasets under subject-disjoint splits. The paper reports strong Macro-F1 and Micro-F1 performance compared with conventional machine learning methods, deep learning classifiers, general-purpose VLMs, ECG-oriented VLMs, and matched non-agentic fusion baselines.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "1.\tClinically meaningful problem formulation.\nThis work addresses the central challenge of beat-level ECG arrhythmia classification under segment-level rhythm context. The paper correctly emphasizes that arrhythmia labels often depend on more than isolated beat morphology, especially for distinguishing VEB and SVEB.\n2.\tClear motivation for segment-contextualized prediction.\nThe introduction gives a convincing explanation of why local beat crops are insufficient. The discussion of premature beats, compensatory pauses, and contextual morphology is clinically intuitive and well aligned with real ECG interpretation.\n3.\tUseful tool-grounded design.\nThe separation between physiological measurement and evidence integration is a strong design choice. The Peak Detector, Feature Extractor, and Morphology Analyzer provide structured intermediate evidence, making the model more auditable than a purely end-to-end black-box classifier.\n4.\tAdaptive evidence acquisition is practically relevant.\nThe confidence-guided routing mechanism is appealing because additional physiological evidence is not always useful. The paper explicitly considers the trade-off between performance, computational cost, and the risk of noisy auxiliary evidence.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "1.\tHow robust is DeepArrhythmia to R-peak detection errors? Can the authors report performance under artificially perturbed, missed, or extra R-peak anchors?\n2.\tHow often does the routed model select the rich-evidence path on each dataset, and how does this correlate with segment difficulty, noise level, or arrhythmia class?\n3.\tHow well calibrated are the confidence scores used for routing? Did the authors evaluate ECE, reliability diagrams, or calibration under domain shift?\n4.\tSince the Morphology Analyzer is trained with label-conditioned teacher distillation, how do the authors ensure that it provides morphology evidence rather than implicit label leakage?\n5.\tWould the method still outperform baselines if the Morphology Analyzer were removed entirely and only numerical features were used?\n6.\tHow sensitive is performance to the selected routing threshold? Is there a wide plateau or a narrow optimum?\n7.\tCan the authors provide per-class F1, especially for S, V, and F classes, rather than only Macro-F1 and Micro-F1?\n8.\tWhat are the most common failure modes on fusion beats and supraventricular ectopic beats?\n9.\tHow does DeepArrhythmia perform under cross-dataset evaluation, and what are the main reasons for the observed generalization gap?\n10.\tIs the system intended for offline Holter-style analysis, bedside monitoring, or real-time arrhythmia detection? The deployment scenario should be clarified.",
+ "limitations": "1.\tThe novelty is mostly system integration rather than a fundamentally new algorithm.\nThe main components—peak detection, feature extraction, morphology analysis, multimodal fusion, and confidence routing—are individually familiar. The novelty lies in their integration. This is still useful, but the paper should avoid overstating the algorithmic contribution.\n2.\tThe Morphology Analyzer depends on teacher distillation and may introduce hidden label priors.\nThe Morphology Analyzer is trained using label-conditioned teacher distillation, even though it is used without labels at inference time. This raises concerns that the analyzer may inherit diagnostic priors from the teacher rather than only describing morphology.\n3.\tFairness of comparisons with VLM baselines is imperfect.\nThe authors append Peak Detector and Feature Extractor outputs to language-model baselines, but exclude the Morphology Analyzer because it is dataset-specific. This is reasonable, but it also means DeepArrhythmia has access to an additional trained evidence source that other VLM baselines do not. The comparison therefore mixes framework advantages with dataset-specific tool specialization.\n4.\tRouting policy is relatively simple.\nThe confidence-guided routing is based on average beat-level max softmax probability. This is a pragmatic design, but confidence can be poorly calibrated, especially under domain shift, noisy recordings, rare rhythms, and different acquisition devices.\n5.\tThreshold selection may overfit dataset-specific validation behavior.\nThe dataset-specific threshold is selected on a held-out route-induction split. While this is acceptable, the method may be sensitive to validation distribution and may not transfer well to new hospitals or devices.",
+ "rating": 5,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "The paper is generally well organized and technically clear.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I maintain my score of 5.\n\nThe rebuttal successfully addressed most of my technical concerns. In particular, the authors provided additional evidence supporting the faithfulness of the Morphology Analyzer, clarified the fairness of comparisons with VLM baselines, and demonstrated the robustness of the confidence-guided routing mechanism. These responses increased my confidence in the correctness and practical value of the proposed framework.\n\nHowever, my main reservation remains unchanged: the primary contribution is a well-designed integration of existing components (peak detection, feature extraction, morphology analysis, multimodal fusion, and confidence routing), rather than a fundamentally new algorithmic innovation. In addition, although cross-dataset analysis is provided, broader external validation remains limited.\n\nTherefore, I believe the paper is technically solid and valuable as a system-oriented contribution, but the current evidence does not justify a stronger recommendation. I maintain my rating of 5."
+ },
+ "createdAt": "2026-06-26T14:16:11.567Z",
+ "modifiedAt": "2026-11-18T13:39:42.021Z",
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6&noteId=xJU5hEX1Pp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/i8jkjyojy6/submission.json added

+++ b/reviews/openreview/i8jkjyojy6/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "i8JkJYOjY6",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 15373,
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6",
+ "license": "CC-BY-4.0"
+}

versions/v_883x7xrw.json added

+++ b/versions/v_883x7xrw.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-05-03",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 15373,
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6",
+ "reviews": "openreview/i8jkjyojy6",
+ "evidence": [
+ "https://openreview.net/forum?id=i8JkJYOjY6"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=i8JkJYOjY6",
+ "evidence": [
+ "https://openreview.net/forum?id=i8JkJYOjY6"
+ ]
+}