potentialpaper

CodeQuant2: Enhanced Outlier Mitigation and Adaptive Clustering for Low-Precision LRMs

Update NeurIPS 2026 submission jS7aRiV05d: 26 notes

@openreview[bot] · 2026-11-24 15:54 UTC · 5a3960ee2f99 ·

Evidence

reviews/openreview/js7ariv05d/notes/2dx7y5wnu7.json added

+++ b/reviews/openreview/js7ariv05d/notes/2dx7y5wnu7.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "2dx7Y5WNU7",
+ "replyTo": "H3VwfNeO1d",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Follow-up on Our Response",
+ "comment": "Thank you again for your comments. We have provided targeted responses to the weaknesses raised in your review. We would appreciate your feedback on whether our response addresses your concerns or if further clarification is needed."
+ },
+ "createdAt": "2026-08-02T02:58:25.608Z",
+ "modifiedAt": "2026-11-19T16:51:38.280Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=2dx7Y5WNU7",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/antalgipmx.json added

+++ b/reviews/openreview/js7ariv05d/notes/antalgipmx.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "aNTALgIPmx",
+ "replyTo": "XpehB2xTd6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Weakness 3",
+ "comment": "We first clarify that RAC is a calibration-selection method, not an inference-time routing system. **The reported 1.0-point average gain is the marginal gain of RAC after rotation and scaling, ACA, and learnable clustering are already enabled.** Table 3 directly compares the same pipeline with and without RAC. \n\nTable 3. Direct contribution of RAC after all other ClusQuant components are enabled. \n| RAC | AIME25@Pass1 | AIME26@Pass1 | Six-task average |\n|:---:|---:|---:|---:|\n| No | 0.546 | 0.567 | 0.760 |\n| Yes | 0.563 | 0.613 | 0.770 |\n\nAs shown in Table 3, RAC improves AIME25 by 1.7 points and AIME26 by 4.6 points. These gains are larger than the 1.0-point change in the six-task average. The average combines easier and harder benchmarks, so it hides the stronger effect of RAC on difficult reasoning tasks.\nThe RAC ablation above measures the contribution of RAC. To test whether the AIME gains depend on a single stochastic generation, we additionally evaluate Pass@8 under A4W4. Pass@8 measures whether the model produces at least one correct answer across eight stochastic generations.\n\nTable 4. AIME Pass@8 accuracy under A4W4 quantization.\n| Benchmark | Best baseline | ClusQuant | Improvement |\n|---|---:|---:|---:|\n| AIME25 Pass@8 | 0.500 | **0.800** | +0.300 |\n| AIME26 Pass@8 | 0.667 | **0.800** | +0.133 |\n\n**Table 4 shows that ClusQuant improves Pass@8 by 0.300 on AIME25 and 0.133 on AIME26.** The advantage remains when each problem is sampled eight times, rather than appearing only in a single Pass@1 generation."
+ },
+ "createdAt": "2026-07-29T04:35:33.073Z",
+ "modifiedAt": "2026-11-19T16:51:38.627Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=aNTALgIPmx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/coeaehw7zo.json added

+++ b/reviews/openreview/js7ariv05d/notes/coeaehw7zo.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "cOEAeHW7ZO",
+ "replyTo": "sYKlqWEifs",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Question 4",
+ "comment": "Thank you for raising this question. **ClusQuant is not designed to correct a semantically invalid reasoning step already produced by the full-precision model.** Its goal is to reduce the additional numerical perturbations introduced by quantization. This helps the quantized model preserve the behavior of the full-precision model and reduces the risk that an otherwise valid trajectory diverges after quantization.\n\nWithin this scope, **we define consistency as repeated-sampling reliability, meaning that successful reasoning trajectories remain available across different stochastic samples.** We evaluate this reliability using both Pass@1 and Pass@8 under A4W4 quantization. Pass@1 measures the probability of success in one generation. Pass@8 measures whether at least one correct result is produced among eight stochastic samples. Table 6 reports the results.\n\nTable 6. AIME accuracy under single and repeated sampling with A4W4 quantization.\n| Benchmark | Metric | Best baseline ↑ | ClusQuant ↑ | Improvement |\n|---|---|---:|---:|---:|\n| AIME25 | Pass@1 | 0.392 | **0.563** | +0.171 |\n| AIME25 | Pass@8 | 0.500 | **0.800** | +0.300 |\n| AIME26 | Pass@1 | 0.367 | **0.613** | +0.246 |\n| AIME26 | Pass@8 | 0.667 | **0.800** | +0.133 |\n\n**As shown in Table 6, ClusQuant improves both individual-sample success and repeated-sampling reliability.** The Pass@1 gains show that a single quantized generation is more likely to remain successful. The Pass@8 gains show that successful reasoning remains available across repeated stochastic sampling. These results support stronger consistency against quantization-induced divergence."
+ },
+ "createdAt": "2026-07-29T04:48:36.138Z",
+ "modifiedAt": "2026-11-19T16:51:38.424Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=cOEAeHW7ZO",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/cua9sjkca6.json added

+++ b/reviews/openreview/js7ariv05d/notes/cua9sjkca6.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "CUA9sjKcA6",
+ "replyTo": "IoSLyS8K9p",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer 9yMQ",
+ "content": {
+ "comment": "Thank you for your detailed response and clarification. I appreciate the authors’ efforts in addressing my concerns. The response has sufficiently clarified the issues I raised, and I will therefore maintain my positive score."
+ },
+ "createdAt": "2026-08-04T07:00:57.870Z",
+ "modifiedAt": "2026-11-19T16:51:38.042Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=CUA9sjKcA6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/dnrghln8qb.json added

+++ b/reviews/openreview/js7ariv05d/notes/dnrghln8qb.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "DNRghLN8Qb",
+ "replyTo": "H3VwfNeO1d",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Weakness 2",
+ "comment": "Rotation and scaling are commonly used in W4A4 quantization methods such as SmoothQuant, QuaRot, SpinQuant, and CodeQuant. We do not treat their use as a standalone contribution of ClusQuant. The transform-related contribution evaluated here is their joint fine-tuning. Our ablation measures this gain separately from ACA, learnable clustering, and RAC.\n\nWe compare fixed random rotation and SmoothQuant scaling against jointly fine-tuned rotation and scaling. ACA, learnable clustering, and RAC are disabled in both settings. Table 4 then reports the complete cumulative ablation.\n\nTable 4. Cumulative ablation of joint rotation and scaling fine-tuning and the proposed ClusQuant components. \n\n| R&S fine-tuning | ACA | Centroid tuning | Assignment tuning | RAC | C4 PPL ↓ | Wiki2 PPL ↓ | Math-500 ↑ | GSM8K ↑ | AIME25@Pass1 ↑ | AIME26@Pass1 ↑ | HumanEval ↑ | LiveCodeBench ↑ | Average ↑ | Average gain |\n|:---:|:---:|:---:|:---:|:---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| No | No | No | No | No | 21.410 | 13.623 | 0.930 | 0.929 | 0.392 | 0.367 | 0.902 | 0.464 | **0.664** | – |\n| Yes | No | No | No | No | 20.148 | 12.811 | 0.928 | 0.934 | 0.450 | 0.421 | 0.933 | 0.5573 | **0.704** | **+4.00 points** |\n| Yes | Yes | No | No | No | 20.837 | 13.125 | 0.938 | 0.938 | 0.542 | 0.4875 | 0.937 | 0.5991 | **0.740** | **+3.64 points** |\n| Yes | Yes | Yes | Yes | No | 21.002 | 13.232 | 0.950 | 0.937 | 0.546 | 0.567 | 0.939 | 0.619 | **0.760** | **+1.94 points** |\n| Yes | Yes | Yes | Yes | Yes | 20.203 | 12.721 | 0.950 | 0.938 | 0.563 | 0.613 | 0.945 | 0.614 | **0.770** | **+1.08 points** |\n\nAs shown in Table 4, jointly fine-tuning rotation and scaling improves the average reasoning accuracy from 0.664 to 0.704, a gain of 4.0 points. We keep this fine-tuned transformation fixed in the remaining rows. **ACA, learnable clustering, and RAC further improve the average to 0.740, 0.760, and 0.770, respectively. Together, these proposed components provide another 6.6 points.** The ablation therefore separates the gain from transform fine-tuning from the gains of the proposed ClusQuant components."
+ },
+ "createdAt": "2026-07-29T04:43:20.704Z",
+ "modifiedAt": "2026-11-19T16:51:38.682Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=DNRghLN8Qb",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/f9rd8qitbp.json added

+++ b/reviews/openreview/js7ariv05d/notes/f9rd8qitbp.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "F9RD8qItBp",
+ "replyTo": "KYuIh14TUy",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Meta Review",
+ "comment": "Thank you for identifying the main concerns. Our rebuttal adds controlled component ablations, a matched ACA comparison, broader evidence for RAC, a clarified baseline protocol, and additional kernel analysis. These results directly address attribution, generality, fairness, and system efficiency. We summarize the main evidence below and refer to the detailed reviewer responses.\n\n- **The main components provide distinct improvements.** Joint rotation and scaling fine-tuning raises the reasoning average from 0.664 to 0.704. ACA, learnable clustering, and RAC further raise it to 0.740, 0.760, and 0.770. On AIME25 and AIME26, ACA adds 9.2 and 6.7 points, learnable clustering adds 0.4 and 7.9 points, and RAC adds 1.7 and 4.6 points. See Reviewer LxGg, Weakness 2 and Reviewer KwSk, Weakness 5 for the complete per-benchmark ablations.\n- **ACA provides a better accuracy–throughput trade-off than fixed capacity.** ACA achieves 0.770 reasoning accuracy at 92 tokens/s, compared with 0.750 at 86 tokens/s for fixed \\(K=16\\) and 0.790 at 75 tokens/s for fixed \\(K=32\\). Each \\(16 -> 32\\) promotion is paired with an ACA-selected \\(16 -> 8\\) demotion. This preserves an average assignment width of 4 bits. The final \\(K=8/16/32\\) distribution is 27/126/27 matrices. See Reviewer LxGg, Weakness 1 for the complete comparison, allocation rule, and layer-wise distribution.\n- **RAC is supported by token-range, mixture, model, and non-reasoning controls.** The first 256 reasoning tokens achieve the best reasoning average of 0.770, compared with 0.721 when using the full 768-token trace. A WikiText2:RAC sweep identifies 9:1 as the best mixture. We also observe the early-token pattern across additional reasoning models and datasets. After sweeping hyper-parameters, Phi-specific tuning further raises the Phi-4-Reasoning average from 0.564 to 0.575. See Reviewer KwSk, Weaknesses 2 and 6 and Reviewer 9yMQ, Questions 1 and 2 for details.\n- **The baseline comparison uses matched calibration resources, activation preprocessing, precision, and quantization granularity.** QuaRot retains its native random rotation. Methods that optimize transformations use the same RAC-selected calibration data and optimization budget. SqueezeLLM and ParoQuant utilized ClusQuant’s RAC-trained rotation and scaling before applying their own weight-quantization algorithms. ParoQuant is also adjusted to the same per-channel weight granularity as ClusQuant. See Reviewer LxGg, Weakness 3 for the complete protocol.\n- **System comparison.** CodeQuant reports simulated A4W4 kernel performance using Accel-Sim with CodeQuant-specific optimized tensor-core hardware settings. We measure ClusQuant with executable CUDA kernels on unmodified A6000, L40S, and A100 GPUs. ParoQuant’s released system implementation uses online rotation and a W4A16 AWQ kernel, while our system table measures end-to-end W4A4 execution without online rotation. **We therefore do not report direct throughput ratios against CodeQuant or ParoQuant.** Both methods remain included in the matched accuracy comparison. See Reviewer KwSk, Weakness 4 and Reviewer LxGg, Weakness 3 for details. \n- **Kernel results.** The LUT uses 8 KB out of 164 KB on-chip memory per thread block, and the average weight storage is 4.2 bits per weight. Profiling shows ClusQuant kernel achieves 71% fewer global-memory reads compared to FP16 baseline. ClusQuant achieves a 2.28–2.48× speedup across batch sizes 1–16 over FP16 baseline. The average padding overhead is below 0.2%. See Reviewer 9yMQ, Question 3 for the complete profiling results and workload settings. \n\n**Together, these results isolate the main component gains, establish ACA’s accuracy–throughput benefit, validate RAC across settings, and clarify the matched baseline and system protocols.**"
+ },
+ "createdAt": "2026-07-29T04:52:39.394Z",
+ "modifiedAt": "2026-11-19T16:51:38.345Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=F9RD8qItBp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/flpxu51ffw.json added

+++ b/reviews/openreview/js7ariv05d/notes/flpxu51ffw.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "flPXU51Ffw",
+ "replyTo": "XpehB2xTd6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Weakness 1",
+ "comment": "We agree that early reasoning can include false starts, dead ends, or incorrect hypotheses. **However, RAC does not assume that these early tokens are semantically correct. Instead, RAC uses them as reconstruction targets to keep the quantized model close to the full-precision model.** The selected tokens are therefore not correctness labels but quantization-sensitive. If the full-precision model follows an incorrect path, RAC aims to preserve its behavior while reducing additional errors introduced by quantization. Correcting the reasoning path would require a different training objective based on semantic or reward signals.\n\nOur choice of early tokens is based on their numerical behavior. **Early reasoning tokens show larger activation fluctuations and higher quantization sensitivity, and errors introduced at this stage can affect the rest of the generation.** This makes them important calibration targets even when their semantic content is uncertain. We will revise the paper to clearly separate these two points. RAC targets quantization-sensitive tokens, while the correctness of the original reasoning path remains a property of the full-precision model."
+ },
+ "createdAt": "2026-07-29T04:33:21.137Z",
+ "modifiedAt": "2026-11-19T16:51:38.651Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=flPXU51Ffw",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/fzw8mbb3cs.json added

+++ b/reviews/openreview/js7ariv05d/notes/fzw8mbb3cs.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "fzw8mBb3Cs",
+ "replyTo": "XpehB2xTd6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Questions",
+ "comment": "We appreciate the reviewer’s constructive assessment and the opportunity to provide stronger empirical support. We provide the following evidence focused on reasoning-aware calibration and the closest system baseline:\n\n- **Direct RAC ablation:** Under the same model, quantization pipeline, calibration-data volume, and optimization budget, changing only the calibration selection to RAC improves AIME25 from 0.546 to 0.563 and AIME26 from 0.567 to 0.613.\n- **RAC robustness:** The early-stage activation fluctuation also appears in GPT-OSS-20B and Qwen3-30B-A3B-Thinking, as well as on MATH-500 and AIME. It does not appear in the standard Qwen3-4B model or in the non-reasoning mode of Qwen3-8B. The calibration-length sweep further shows that the reasoning average peaks at 0.770 with the first 256 tokens.\n- **Phi-4 validation:** Due to limited GPU resources, the submitted Phi-4 experiment reused the Qwen3 training configuration without a Phi-specific hyperparameter sweep. After Phi-specific tuning, the reasoning average improves from 0.564 to 0.575, compared with 0.559 for CodeQuant. The improvement also remains under AIME25 and AIME26 Pass@8 repeated sampling.\n- **CodeQuant system comparison:** CodeQuant reports its A4W4 result using Accel-Sim with CodeQuant-optimized tensor cores. Our CUDA results are measured on unmodified commodity GPUs. We therefore restrict the 2.42× speedup claim to runnable baselines evaluated under the same hardware and precision.\n\nWe hope that this additional evidence addresses the reviewer’s main concerns about RAC and supports reconsideration of the score."
+ },
+ "createdAt": "2026-07-29T04:40:24.086Z",
+ "modifiedAt": "2026-11-19T16:51:38.577Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=fzw8mBb3Cs",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/h7zpogklhd.json added

+++ b/reviews/openreview/js7ariv05d/notes/h7zpogklhd.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "H7zPOgKlHD",
+ "replyTo": "sYKlqWEifs",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Question 2",
+ "comment": "**In the original submission, we did not separately tune the hyper-parameters for Phi-4.** Due to limited GPU resources, we directly **used the hyperparameters tuned for Qwen3-4B-Thinking.** We have now retrained Phi-4 with model-specific hyperparameters under the same evaluation protocol. Table 2 reports the complete results.\n\nTable 2. Phi-4-Reasoning results under A4W4 before and after Phi-specific hyperparameter tuning.\n\n| Method | C4 PPL ↓ | WikiText2 PPL ↓ | Math-500 ↑ | GSM8K ↑ | AIME25@Pass1 ↑ | AIME26@Pass1 ↑ | HumanEval ↑ | LiveCodeBench ↑ | Average ↑ |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| BF16 | 13.187 | 7.393 | 0.858 | 0.943 | 0.283 | 0.250 | 0.872 | 0.410 | 0.603 |\n| QuaRot | 16.564 | 9.511 | 0.766 | 0.908 | 0.192 | 0.129 | 0.640 | 0.238 | 0.479 |\n| SqueezeLLM | 14.871 | 8.375 | 0.806 | 0.921 | 0.258 | 0.188 | 0.750 | 0.321 | 0.541 |\n| ParoQuant | 16.584 | 9.489 | 0.770 | 0.908 | 0.183 | 0.150 | 0.683 | 0.235 | 0.488 |\n| CodeQuant | 14.358 | 8.087 | 0.840 | 0.940 | 0.246 | 0.242 | 0.732 | 0.353 | 0.559 |\n| ClusQuant, Qwen3 configuration | 14.316 | 8.074 | 0.844 | 0.944 | 0.271 | 0.225 | 0.726 | 0.374 | 0.564 |\n| **ClusQuant, Phi-tuned** | 13.660 | 7.739 | 0.840 | 0.932 | 0.246 | 0.250 | 0.823 | 0.362 | **0.575** |\n\n**As shown in Table 2, Phi-specific tuning improves the average reasoning accuracy from 0.564 to 0.575 and increases the margin over CodeQuant from 0.5 to 1.6 points.** It also reduces C4 and WikiText2 perplexity from 14.316 and 8.074 to 13.660 and 7.739.\n\nWe also evaluate the tuned model under repeated sampling. Table 3 reports AIME Pass@1 and Pass@8.\n\nTable 3. Phi-4-Reasoning accuracy under single and repeated sampling after Phi-specific tuning.\n| Method | Average ↑ | AIME25@Pass1 ↑ | AIME25@Pass8 ↑ | AIME26@Pass1 ↑ | AIME26@Pass8 ↑ |\n|---|---:|---:|---:|---:|---:|\n| CodeQuant | 0.559 | 0.246 | 0.333 | 0.242 | 0.400 |\n| **ClusQuant, Phi-tuned** | **0.575** | 0.246 | **0.400** | **0.250** | **0.433** |\n\nTable 3 shows that the tuned model matches CodeQuant on AIME25 Pass@1 and improves Pass@8 from 0.333 to 0.400. It also improves AIME26 Pass@1 from 0.242 to 0.250 and Pass@8 from 0.400 to 0.433.\n\n**The remaining difference between Qwen3-4B and Phi-4 may also reflect their different quantization headroom.** Phi-4 is substantially larger, and its strong quantized baselines already retain more of the full-precision performance. This leaves less degradation for ClusQuant to recover. Prior work has shown that larger Transformers can retain accuracy better under compression (Li et al., 2020). A recent study of quantized reasoning models also identified model size as an important factor in quantization degradation and found that larger models can achieve better quantized reasoning performance (Liu et al., 2025). We treat model scale as a contributing factor rather than the only explanation because Qwen3 and Phi-4 also differ in architecture and post-training.\n\nReferences:\n\n- [1] Li, Zhuohan, et al. “Train Big, Then Compress: Rethinking Model Size for Efficient Training and Inference of Transformers.” ICML, 2020.\n- [2] Liu, Ruikang, et al. “Quantization Hurts Reasoning? An Empirical Study on Quantized Reasoning Models.” arXiv:2504.04823, 2025."
+ },
+ "createdAt": "2026-07-29T04:47:15.215Z",
+ "modifiedAt": "2026-11-19T16:51:38.418Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=H7zPOgKlHD",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/ioslys8k9p.json added

+++ b/reviews/openreview/js7ariv05d/notes/ioslys8k9p.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "IoSLyS8K9p",
+ "replyTo": "sYKlqWEifs",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Question 1",
+ "comment": "To report the sensitivity to calibration-data composition, we **sweep the ratio between WikiText2 samples and RAC-selected reasoning samples while keeping the total calibration budget fixed.** Table 1 reports the complete results.\n\nTable 1. Sensitivity to the WikiText2 and RAC calibration ratio under a fixed total calibration budget.\n\n| WikiText2:RAC | C4 PPL ↓ | WikiText2 PPL ↓ | Math-500 ↑ | GSM8K ↑ | AIME25@Pass1 ↑ | AIME26@Pass1 ↑ | HumanEval ↑ | LiveCodeBench ↑ | Average ↑ |\n|:---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| 10:0 | 21.002 | 13.232 | 0.950 | 0.937 | 0.546 | 0.567 | 0.939 | 0.619 | 0.760 |\n| **9:1** | 20.203 | 12.721 | 0.950 | 0.938 | 0.563 | 0.613 | 0.945 | 0.614 | **0.770** |\n| 7:3 | 20.742 | 12.263 | 0.954 | 0.942 | 0.563 | 0.594 | 0.933 | 0.595 | 0.763 |\n| 5:5 | 20.674 | 12.280 | 0.942 | 0.936 | 0.533 | 0.538 | 0.939 | 0.568 | 0.743 |\n| 0:10 | 21.056 | 12.545 | 0.940 | 0.942 | 0.479 | 0.542 | 0.945 | 0.549 | 0.733 |\n\nThe sweep intervals are non-uniform by design. Our preliminary experiments showed that WikiText2-dominant mixtures generally perform better. We therefore evaluate the high-WikiText2 region more densely with 10:0, 9:1, and 7:3. We use larger intervals for 5:5 and 0:10 to cover the broader trend toward RAC-heavy calibration.\n\n**As shown in Table 1, performance is stable in the WikiText2-dominant region, and the 9:1 ratio achieves the best overall average of 0.770.** The 10:0 and 7:3 ratios achieve averages of 0.760 and 0.763. The selected 9:1 ratio improves the average by 1.0 point over WikiText2-only calibration and by 3.7 points over RAC-only calibration. We therefore use 9:1 in the main experiments.\n\nWikiText2 provides broad activation coverage for stable transformation optimization. A smaller set of RAC samples adds reasoning-specific activation states that are not well represented by generic text. Increasing the RAC proportion too far reduces the coverage of general activation states and places too much weight on a narrower set of early reasoning trajectories. This explains the lower performance of the RAC-heavy mixtures."
+ },
+ "createdAt": "2026-07-29T04:45:09.152Z",
+ "modifiedAt": "2026-11-19T16:51:38.447Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=IoSLyS8K9p",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/kyuih14tuy.json modified

+++ b/reviews/openreview/js7ariv05d/notes/kyuih14tuy.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair CWwh",
"content": {
- "metareview": "This paper proposes a post-training quantization method for low-precision inference of large reasoning models. It combines rotation and scaling for outlier mitigation, clustering-based weight representations, adaptive allocation of cluster capacity, learnable clustering parameters, and a custom CUDA kernel.\n\nMy current evaluation is borderline reject. The primary concern is that the experiments do not yet cleanly isolate or validate the components that distinguish ClusQuant from closely related quantization systems. In particular, it remains unclear how much of the improvement comes from reasoning-aware calibration, adaptive cluster allocation, rotation and scaling, learnable clustering, or other system-level choices.\n\nThe reasoning-specific calibration claim requires stronger support. The paper motivates calibration using the higher activation variability of early reasoning tokens, but calibration over longer traces reportedly reduces performance, and the benefit appears uneven across model families. It is therefore unclear whether early-token calibration captures a general property of reasoning models or an empirical pattern specific to particular checkpoints and datasets. The currently reported aggregate ablation also appears to show only a modest contribution from this component.\n\nThe adaptive cluster allocation mechanism is similarly insufficiently isolated. The paper does not provide directly comparable accuracy-latency results for adaptive allocation versus fixed cluster counts under the same complete pipeline, nor does it report the resulting distribution of cluster sizes across layers. These omissions make it difficult to determine whether adaptive allocation provides a meaningful advantage over simpler fixed-capacity alternatives.\n\nThe author response should focus on the following:\n1. Provide a controlled attribution of the accuracy improvements to the main components of ClusQuant, especially reasoning-aware calibration, adaptive cluster allocation, and rotation/scaling. Please identify per-benchmark ablations rather than relying only on aggregate averages.\n2. Establish the benefit of adaptive cluster allocation through direct accuracy-latency comparisons against fixed cluster counts under otherwise identical settings. Please also clarify the allocation algorithm and report the cluster capacities selected across layers or modules.\n3. Clarify the evidence for reasoning-aware calibration. In particular, explain why early reasoning tokens are preferable to full-trace or conventional calibration, how sensitive the result is to the calibration mixture and token range, and why the benefit differs substantially between Qwen and Phi-4.\n4. Confirm that all accuracy baselines use comparable calibration data, token budgets, and optimization procedures. For methods extended from weight-only to weight-and-activation quantization, clarify whether their transformations were re-optimized under the same conditions.\n5. Strengthen the systems comparison with the closest LUT-based methods, particularly CodeQuant, and clarify why relevant accuracy baselines are omitted from some latency or throughput comparisons.\n6. Provide additional implementation details concerning kernel memory overhead, batch-size sensitivity, and the conditions under which the reported speedups hold.\n\n\n====Post Rebuttal====\nMy main concerns in the initial meta-review were whether the gains from the individual components were isolated and whether the baseline comparisons were fair. The rebuttal addressed these concerns with additional ablations, matched fixed-capacity comparisons for ACA, and further clarifications for the baselines. The reviewers also generally found these responses satisfactory and all now give positive scores. Therefore, I change my original recommendation and now recommend acceptance.\n\nAlso, authors should fix the reported reference issue. To me it doesn't look at an AI hallucination though."
+ "metareview": "This paper proposes a post-training quantization method for low-precision inference of large reasoning models. It combines rotation and scaling for outlier mitigation, clustering-based weight representations, adaptive allocation of cluster capacity, learnable clustering parameters, and a custom CUDA kernel.\n\nMy current evaluation is borderline reject. The primary concern is that the experiments do not yet cleanly isolate or validate the components that distinguish ClusQuant from closely related quantization systems. In particular, it remains unclear how much of the improvement comes from reasoning-aware calibration, adaptive cluster allocation, rotation and scaling, learnable clustering, or other system-level choices.\n\nThe reasoning-specific calibration claim requires stronger support. The paper motivates calibration using the higher activation variability of early reasoning tokens, but calibration over longer traces reportedly reduces performance, and the benefit appears uneven across model families. It is therefore unclear whether early-token calibration captures a general property of reasoning models or an empirical pattern specific to particular checkpoints and datasets. The currently reported aggregate ablation also appears to show only a modest contribution from this component.\n\nThe adaptive cluster allocation mechanism is similarly insufficiently isolated. The paper does not provide directly comparable accuracy-latency results for adaptive allocation versus fixed cluster counts under the same complete pipeline, nor does it report the resulting distribution of cluster sizes across layers. These omissions make it difficult to determine whether adaptive allocation provides a meaningful advantage over simpler fixed-capacity alternatives.\n\nThe author response should focus on the following:\n1. Provide a controlled attribution of the accuracy improvements to the main components of ClusQuant, especially reasoning-aware calibration, adaptive cluster allocation, and rotation/scaling. Please identify per-benchmark ablations rather than relying only on aggregate averages.\n2. Establish the benefit of adaptive cluster allocation through direct accuracy-latency comparisons against fixed cluster counts under otherwise identical settings. Please also clarify the allocation algorithm and report the cluster capacities selected across layers or modules.\n3. Clarify the evidence for reasoning-aware calibration. In particular, explain why early reasoning tokens are preferable to full-trace or conventional calibration, how sensitive the result is to the calibration mixture and token range, and why the benefit differs substantially between Qwen and Phi-4.\n4. Confirm that all accuracy baselines use comparable calibration data, token budgets, and optimization procedures. For methods extended from weight-only to weight-and-activation quantization, clarify whether their transformations were re-optimized under the same conditions.\n5. Strengthen the systems comparison with the closest LUT-based methods, particularly CodeQuant, and clarify why relevant accuracy baselines are omitted from some latency or throughput comparisons.\n6. Provide additional implementation details concerning kernel memory overhead, batch-size sensitivity, and the conditions under which the reported speedups hold.\n\n\n====Post Rebuttal====\nMy main concerns in the initial meta-review were whether the gains from the individual components were isolated and whether the baseline comparisons were fair. The rebuttal addressed these concerns with additional ablations, matched fixed-capacity comparisons for ACA, and further clarifications for the baselines. The reviewers also generally found these responses satisfactory and all now give positive scores. Therefore, I change my original recommendation and now recommend acceptance.\n\nAlso, authors should fix the reported reference issue. To me it doesn't look at an AI hallucination though.",
+ "final_justification": "see above under \"Post Rebuttal\""
},
"createdAt": "2026-07-24T04:44:41.281Z",
- "modifiedAt": "2026-11-18T15:21:36.982Z",
+ "modifiedAt": "2026-11-19T05:00:58.764Z",
"url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=KYuIh14TUy",
"license": "CC-BY-4.0"
}

reviews/openreview/js7ariv05d/notes/lchqet6skq.json added

+++ b/reviews/openreview/js7ariv05d/notes/lchqet6skq.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "LCHQeT6sKq",
+ "replyTo": "XpehB2xTd6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Follow-up on Our Response",
+ "comment": "Thank you again for your comments. We have provided targeted responses to the weaknesses raised in your review. We would appreciate your feedback on whether our response addresses your concerns or if further clarification is needed."
+ },
+ "createdAt": "2026-08-02T02:58:13.295Z",
+ "modifiedAt": "2026-11-19T16:51:38.112Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=LCHQeT6sKq",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/mdgcwk7jra.json added

+++ b/reviews/openreview/js7ariv05d/notes/mdgcwk7jra.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "mdgcwK7Jra",
+ "replyTo": "vTgmOR98q8",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer LxGg",
+ "content": {
+ "comment": "Thank you for your efforts. I still have my reservations about this being a faithful reproduction of ParoQuant, but the results indicate the proposed transform is effective. I have raised my score.\n\nI encourage the author to directly apply the methods from the ParoQuant paper for W4A4 and use that as a baseline, and update the baseline results in the paper."
+ },
+ "createdAt": "2026-08-03T16:36:32.919Z",
+ "modifiedAt": "2026-11-19T16:51:38.055Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=mdgcwK7Jra",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/mijj8mxurb.json added

+++ b/reviews/openreview/js7ariv05d/notes/mijj8mxurb.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "mIJJ8mxurb",
+ "replyTo": "H3VwfNeO1d",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Weakness 1",
+ "comment": "We agree that the original paper did not provide a complete accuracy–latency comparison or explain the ACA selection rule clearly enough. **ACA starts every target matrix with \\(K=16\\) and applies cluster changes in pairs. Each promotion from \\(K=16\\) to \\(K=32\\) is paired with a demotion of another matrix from \\(K=16\\) to \\(K=8\\).** The promotion changes the assignment width from 4 to 5 bits, while the demotion changes it from 4 to 3 bits. Each pair therefore **preserves the average assignment width at 4 bits.** This makes uniform \\(K=16\\) the capacity-matched reference for the dominant index storage.\n\nACA uses the gradient-weighted reconstruction score in Eq. 2 together with matrix-specific LUT latency measured on the target GPU. For a promotion, ACA selects the matrix that benefits most from increasing \\(K\\) from 16 to 32. It then applies the same criterion to select the matrix with the lowest cost when reducing \\(K\\) from 16 to 8. The two changes are applied together within the target latency budget.\n\nWe compare fixed \\(K in \\{8,16,32\\}\\) and ACA using the same complete Qwen3-4B-Thinking pipeline. Table 1 reports both task accuracy and decoding throughput.\n\nTable 1. Accuracy and throughput of fixed cluster counts and ACA under the same complete pipeline.\n\n| K | C4 ↓ | Wiki2 ↓ | Math-500 ↑ | GSM8K ↑ | AIME25@Pass1 ↑ | AIME26@Pass1 ↑ | HumanEval ↑ | LiveCodeBench ↑ | Average ↑ | Throughput |\n|:---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| 8 | 25.25 | 16.96 | 0.76 | 0.86 | 0.15 | 0.12 | 0.13 | 0.01 | 0.34 | 94 tokens/s |\n| 16 | 20.56 | 12.95 | 0.94 | 0.94 | 0.53 | 0.56 | 0.94 | 0.59 | 0.75 | 86 tokens/s |\n| 32 | 19.78 | 11.76 | 0.96 | 0.95 | 0.60 | 0.64 | 0.95 | 0.63 | 0.79 | 75 tokens/s |\n| **ACA** | 20.20 | 12.72 | 0.95 | 0.94 | 0.56 | 0.61 | 0.95 | 0.61 | **0.77** | **92 tokens/s** |\n\n**Table 1 shows that ACA provides a better accuracy–latency balance than the fixed settings.** Compared with fixed \\(K=16\\), ACA improves the average reasoning accuracy from 0.75 to 0.77 and increases throughput from 86 to 92 tokens/s. It also reduces C4 and WikiText2 perplexity from 20.56 and 12.95 to 20.20 and 12.72. Compared with fixed \\(K=32\\), ACA remains within 2.0 accuracy points while providing 22.7% higher throughput. It also avoids the large accuracy loss of fixed \\(K=8\\) while retaining similar throughput.\n\nWe also report the final ACA allocation by projection type and layer range in Tables 2 and 3.\n\nTable 2. Final ACA cluster allocation by projection type.\n\n| Projection | \\(K=8\\) | \\(K=16\\) | \\(K=32\\) |\n|---|---:|---:|---:|\n| `attn.q_proj` | 14 (38.9%) | 22 (61.1%) | 0 (0.0%) |\n| `attn.k_proj` | 9 (25.0%) | 16 (44.4%) | 11 (30.6%) |\n| `attn.v_proj` | 1 (2.8%) | 20 (55.6%) | 15 (41.7%) |\n| `mlp.gate_proj` | 2 (5.6%) | 34 (94.4%) | 0 (0.0%) |\n| `mlp.up_proj` | 1 (2.8%) | 34 (94.4%) | 1 (2.8%) |\n| **Overall** | **27 (15.0%)** | **126 (70.0%)** | **27 (15.0%)** |\n\nTable 3. Final ACA cluster allocation by layer range. \n\n| Layer range | Matrices | \\(K=8\\) | \\(K=16\\) | \\(K=32\\) |\n|---|---:|---:|---:|---:|\n| Early, layers 0–11 | 60 | 20 (33.3%) | 39 (65.0%) | 1 (1.7%) |\n| Middle, layers 12–23 | 60 | 5 (8.3%) | 46 (76.7%) | 9 (15.0%) |\n| Late, layers 24–35 | 60 | 2 (3.3%) | 41 (68.3%) | 17 (28.3%) |\n| **Overall** | **180** | **27 (15.0%)** | **126 (70.0%)** | **27 (15.0%)** |\n\n**Tables 2 and 3 show that the learned allocation is structured rather than uniform or random.** ACA assigns \\(K=32\\) mainly to key and value projections. Specifically, 30.6% of k_proj matrices and 41.7% of v_proj matrices receive \\(K=32\\). Capacity also shifts toward later layers. The number of \\(K=32\\) matrices increases from 1 in layers 0–11 to 9 in layers 12–23 and 17 in layers 24–35. Overall, \\(K=8\\) and \\(K=32\\) are each assigned to 27 matrices, which matches the paired allocation rule."
+ },
+ "createdAt": "2026-07-29T04:42:17.839Z",
+ "modifiedAt": "2026-11-19T16:51:38.571Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=mIJJ8mxurb",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/mvz4qkezel.json added

+++ b/reviews/openreview/js7ariv05d/notes/mvz4qkezel.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "MVZ4QKEZeL",
+ "replyTo": "KYuIh14TUy",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Final Rebuttal Update",
+ "comment": "Thank you for considering our rebuttal. Our response to the meta-review already summarizes the new component ablations, matched ACA comparison, broader RAC validation, clarified baseline protocol, and kernel profiling. We therefore provide only the main update from the subsequent discussion.\n\n**To address the remaining concern about ParoQuant, we used the released ParoQuant code and Appendix A.3 to reproduce its W4A4 setting under matched calibration and optimization budgets.** We now distinguish three settings: the direct ParoQuant W4A4 reproduction, the ParoQuant + RAC setting used in our submission, and ClusQuant. Across Qwen3-4B-Thinking and Qwen3-8B on WikiText2 and C4, RAC substantially improves ParoQuant, while ClusQuant achieves the lowest perplexity.\n\n**Reviewer LxGg reviewed this additional evidence, acknowledged the effectiveness of the proposed transform, and raised the score. All three reviewers now rate the paper 4.** In the revision, we will report the three ParoQuant-related settings separately and clearly explain their implementation differences. Together with the evidence summarized in our meta-review response, the rebuttal now directly addresses the main concerns about component attribution, RAC generality, ACA effectiveness, baseline construction, and system evaluation."
+ },
+ "createdAt": "2026-08-04T04:15:58.319Z",
+ "modifiedAt": "2026-11-19T16:51:37.980Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=MVZ4QKEZeL",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/oqa3fbwbmu.json added

+++ b/reviews/openreview/js7ariv05d/notes/oqa3fbwbmu.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "OQA3FBWbmU",
+ "replyTo": "XpehB2xTd6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Weakness 6",
+ "comment": "We agree that the contribution of RAC should be more clearly isolated. We therefore conducted an additional ablation study. We therefore compare standard calibration and RAC using the same model, quantization pipeline, calibration-data volume, and optimization budget. The only difference is which activation states are selected for calibration. Rotation, scaling, and learnable clustering are optimized normally under each setting. **Changing the calibration selection to RAC improves AIME25 from 0.546 to 0.563 and AIME26 from 0.567 to 0.613. It also improves the six-task average from 0.760 to 0.770.** This controlled comparison directly measures the contribution of RAC.\n\nThe main comparison also provides RAC-based activation preprocessing to the relevant baselines. QuaRot retains its native random rotation. Methods with optimized transformations use the same RAC-selected calibration data and matched optimization budget. SqueezeLLM and ParoQuant use ClusQuant’s RAC-trained rotation and scaling before applying their own weight-quantization algorithms. ParoQuant is also evaluated with the same per-channel weight granularity as ClusQuant. This protocol compares the weight-side algorithms under matched activation preprocessing, precision, and granularity.\n\n**The smaller improvement on Phi-4 was mainly caused by insufficient model-specific tuning in the submitted experiments.** Due to limited GPU resources, we did not perform a separate hyperparameter sweep for Phi-4 and directly reused the training configuration developed for Qwen3-4B. We have now retrained the model with Phi-specific hyperparameters under the same evaluation protocol. As shown in Table 7, the six-task average improves from 0.564 to 0.575, compared with 0.559 for CodeQuant. This result shows that model-specific tuning is important for transferring ClusQuant to Phi-4.\n\nTable 7. Phi-4-Reasoning accuracy under A4W4 quantization before and after Phi-specific tuning. \n\n| Bits | Method | Wiki2 ↓ | C4 ↓ | Math-500 ↑ | GSM8K ↑ | AIME25@Pass1 ↑ | AIME26@Pass1 ↑ | HumanEval ↑ | LiveCodeBench ↑ | Average ↑ |\n|:---:|---|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| BF16 | – | 7.393 | 13.187 | 0.858 | 0.943 | 0.283 | 0.250 | 0.872 | 0.410 | 0.603 |\n| A4W4 | QuaRot | 9.511 | 16.564 | 0.766 | 0.908 | 0.192 | 0.129 | 0.640 | 0.238 | 0.479 |\n| A4W4 | SqueezeLLM | 8.375 | 14.871 | 0.806 | 0.921 | 0.258 | 0.188 | 0.750 | 0.321 | 0.541 |\n| A4W4 | ParoQuant | 9.489 | 16.584 | 0.770 | 0.908 | 0.183 | 0.150 | 0.683 | 0.235 | 0.488 |\n| A4W4 | CodeQuant | 8.087 | 14.358 | 0.840 | 0.940 | 0.246 | 0.242 | 0.732 | 0.353 | 0.559 |\n| A4W4 | ClusQuant | 8.074 | 14.316 | 0.844 | 0.944 | 0.271 | 0.225 | 0.726 | 0.374 | 0.564 |\n| A4W4 | ClusQuant, Phi-tuned | 7.739 | 13.660 | 0.840 | 0.932 | 0.246 | 0.250 | 0.823 | 0.362 | **0.575** |\n\nTable 8. Phi-4-Reasoning AIME accuracy under single and repeated sampling. \n\n| Method | Average | AIME25 Pass@1 | AIME25 Pass@8 | AIME26 Pass@1 | AIME26 Pass@8 |\n|---|---:|---:|---:|---:|---:|\n| CodeQuant | 0.559 | 0.246 | 0.333 | 0.242 | 0.400 |\n| ClusQuant, Phi-tuned | **0.575** | 0.246 | **0.400** | **0.250** | **0.433** |\n\nAs shown in Table 8, the Phi-tuned model matches CodeQuant on AIME25 Pass@1 and improves Pass@8 from 0.333 to 0.400. It also improves AIME26 Pass@1 from 0.242 to 0.250 and Pass@8 from 0.400 to 0.433. **Both the average accuracy and repeated-sampling results confirm that the limited gain in the submitted Phi-4 experiment was mainly due to insufficient Phi-specific tuning.**"
+ },
+ "createdAt": "2026-07-29T04:39:03.112Z",
+ "modifiedAt": "2026-11-19T16:51:38.742Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=OQA3FBWbmU",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/q1g2y9xplz.json added

+++ b/reviews/openreview/js7ariv05d/notes/q1g2y9xplz.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Q1G2Y9xPlz",
+ "replyTo": "XpehB2xTd6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Weakness 5",
+ "comment": "We thank the reviewer for raising these two related questions: the task-level attribution of the AIME gains and the smaller margin under A8W4.\n\nFirst, **ClusQuant is designed to address quantization errors in difficult reasoning tasks, where small numerical errors can accumulate across long generation trajectories.** We therefore expect its largest gains on reasoning benchmarks. Conventional language-modeling tasks do not strongly expose these reasoning-specific failure modes, so a smaller gap on these tasks is expected. Importantly, ClusQuant also performs better than CodeQuant on general language modeling. Under A4W4, ClusQuant achieves C4 and WikiText2 perplexities of 20.203 and 12.721, compared with 21.410 and 13.623 for CodeQuant. **The narrow gap on general tasks is therefore expected, while the lower perplexity shows that our reasoning-oriented design preserves and even improves general modeling quality.**\n\nWe agree that the average in the original ablation table does not show how each component affects individual tasks. Table 5 therefore reports the complete cumulative ablation across all six reasoning benchmarks, together with C4 and WikiText2 perplexity.\n\nTable 5. Cumulative component ablation across language modeling and six reasoning benchmarks.\n\n| Configuration | C4 ↓ | Wiki2 ↓ | Math-500 ↑ | GSM8K ↑ | AIME25@Pass1 ↑ | AIME26@Pass1 ↑ | HumanEval ↑ | LiveCodeBench ↑ | Average ↑ |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| R&S | 20.148 | 12.811 | 0.928 | 0.934 | 0.450 | 0.421 | 0.933 | 0.557 | 0.704 |\n| + ACA | 20.837 | 13.125 | 0.938 | 0.938 | 0.542 | 0.488 | 0.937 | 0.599 | 0.740 |\n| + Learnable clustering | 21.002 | 13.232 | 0.950 | 0.937 | 0.546 | 0.567 | 0.939 | 0.619 | 0.760 |\n| + RAC | 20.203 | 12.721 | 0.950 | 0.938 | 0.563 | 0.613 | 0.945 | 0.614 | 0.770 |\n\n**Table 5 shows that the three components provide cumulative gains across the full reasoning suite.** ACA increases the six-task average from 0.704 to 0.740. Learnable clustering further increases it to 0.760. RAC produces the final average of 0.770. The per-task results also show where these gains come from. ACA improves both mathematical and code tasks. Learnable clustering provides further gains on Math-500, AIME26, and LiveCodeBench. RAC improves AIME25, AIME26, HumanEval, and the overall average.\n\nThe AIME columns answer the reviewer’s specific question about difficult reasoning tasks. ACA improves AIME25 and AIME26 by 9.2 and 6.7 points. Learnable clustering adds 0.4 and 7.9 points. RAC adds another 1.7 and 4.6 points. AIME shows the largest gains, but the overall conclusion is based on the complete six-task average.\n**The smaller Qwen3-4B margin under A8W4 comes from lower activation quantization error and reduced optimization headroom for all methods.** A8W4 moves strong methods closer to BF16, so their results become closer. Table 6 compares the ClusQuant margin over CodeQuant across models.\n\nTable 6. ClusQuant reasoning-average margin over CodeQuant under A4W4 and A8W4. \n| Model | A4W4 margin | A8W4 margin |\n|---|---:|---:|\n| Qwen3-4B-Thinking | +10.6 points | +2.9 points |\n| Qwen3-8B | +0.8 points | +2.2 points |\n| Phi-4-Reasoning | +0.5 points | +0.9 points |\n\nAs shown in Table 6, ClusQuant remains ahead of CodeQuant under A8W4 on all three models. The margin becomes smaller on Qwen3-4B-Thinking, while it increases on Qwen3-8B and Phi-4-Reasoning. The smaller Qwen3-4B gap is therefore a result of reduced headroom in this easier quantization setting."
+ },
+ "createdAt": "2026-07-29T04:37:46.611Z",
+ "modifiedAt": "2026-11-19T16:51:38.574Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=Q1G2Y9xPlz",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/qo1amcvzhc.json added

+++ b/reviews/openreview/js7ariv05d/notes/qo1amcvzhc.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "qO1aMcvZHC",
+ "replyTo": "H3VwfNeO1d",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Weakness 3",
+ "comment": "Thank you for raising this concern. Our original description did not clearly explain the calibration data, activation transformations, and weight quantization used for the baselines.\n\nTo ensure a fair comparison, the transformation procedure varies across baselines. QuaRot uses its **original random rotation.** For methods with optimized transformations, we use **the same RAC-selected calibration data** and **optimization budget** to fine-tune rotation and scaling. For SqueezeLLM and ParoQuant, **we first apply the RAC-trained rotation and scaling from ClusQuant and then run each method’s own weight quantization algorithm.**\n\nWe additionally match the calibration sequence count, sequence length, total token budget, target W4A4/W4A8 precision, and quantization granularity. All methods use per-channel weight quantization and per-token activation quantization. **Because ParoQuant originally uses a finer weight granularity, we reconfigure its weight quantizer to the same per-channel granularity used by ClusQuant.** The reported ParoQuant entry therefore compares its weight-side algorithm with ClusQuant under the same activation preprocessing, precision, and weight granularity.\n\nWe also note that the kernel optimization proposed in ParoQuant is orthogonal to ClusQuant. ParoQuant requires an online rotation operation during inference, whereas ClusQuant does not perform any online rotation. Therefore, ParoQuant addresses a different inference pipeline and its kernel optimizations are complementary to our method rather than directly comparable. Instead, we compare against QuaRot, which shares the same rotation-free inference workflow and represents the current state-of-the-art baseline in this setting."
+ },
+ "createdAt": "2026-07-29T04:44:02.165Z",
+ "modifiedAt": "2026-11-19T16:51:38.704Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=qO1aMcvZHC",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/rqazua3gtr.json added

+++ b/reviews/openreview/js7ariv05d/notes/rqazua3gtr.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "RqAZua3GTR",
+ "replyTo": "mIJJ8mxurb",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer LxGg",
+ "content": {
+ "comment": "The rebuttal improves the paper by clarifying the ACA algorithm, adding the missing accuracy–throughput comparison and allocation statistics, and providing a cleaner component ablation. However, I remain concerned about the evaluation protocol for ParoQuant. The revised evaluation replaces ParoQuant’s optimized transform with ClusQuant’s learned transform before applying ParoQuant’s quantization procedure. Since ParoQuant’s primary methodological contribution lies in its optimized transform rather than a distinct weight quantization algorithm, this changes the method being evaluated and makes it difficult to interpret the comparison as a faithful ParoQuant baseline. As this affects one of the paper’s key empirical comparisons, I maintain my evaluation."
+ },
+ "createdAt": "2026-08-02T03:43:22.337Z",
+ "modifiedAt": "2026-11-19T16:51:38.242Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=RqAZua3GTR",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/stj6qije05.json added

+++ b/reviews/openreview/js7ariv05d/notes/stj6qije05.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "sTJ6qiJe05",
+ "replyTo": "sYKlqWEifs",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Follow-up on Our Response",
+ "comment": "Thank you again for your comments. We have provided targeted responses to the weaknesses raised in your review. We would appreciate your feedback on whether our response addresses your concerns or if further clarification is needed."
+ },
+ "createdAt": "2026-08-02T02:58:33.965Z",
+ "modifiedAt": "2026-11-19T16:51:38.270Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=sTJ6qiJe05",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/vipiaftg4f.json added

+++ b/reviews/openreview/js7ariv05d/notes/vipiaftg4f.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "VIPIaFtg4F",
+ "replyTo": "XpehB2xTd6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Weakness 4",
+ "comment": "We agree that random rotation, scaling techniques, non-uniform clustering, and LUT-based execution have substantial prior work, with similar combinations adopted in SpinQuant, OSTQuant, and CodeQuant. **But ClusQuant adds three method-level contributions to the rotation and clustering pipeline.** (i) Matrix-wise ACA assigns cluster capacity based on quantization sensitivity under a latency budget. (ii) Learnable clustering directly optimizes both centroids and assignment variables. (iii) RAC selects quantization-sensitive reasoning tokens for calibration. These algorithmic components are supported by an end-to-end CUDA LUT kernel that runs on unmodified commodity GPUs.\n\n**The component ablation shows that these additions improve the six-task reasoning average from 0.704 to 0.770 on top of the fine-tuned rotation and scaling transform.** Adding ACA increases the average to 0.740. Learnable clustering further increases it to 0.760. RAC produces the final average of 0.770. These gains directly measure the contribution of our method-level changes beyond the shared rotation and scaling pipeline.\n\nThe CodeQuant system result requires a separate clarification. **CodeQuant reports its A4W4 kernel using Accel-Sim** (a GPU simulator) configured with CodeQuant-optimized tensor core hardware. **Our 2.42× speedup is measured using executable CUDA kernels** on unmodified A6000, L40S, and A100 GPUs. A direct comparison between CodeQuant and ClusQuant kernels would mix simulated customized hardware with measured commodity GPUs, which is unfair. We will clarify this difference in the revision. CodeQuant remains included in the matched A4W4 accuracy comparison."
+ },
+ "createdAt": "2026-07-29T04:36:17.322Z",
+ "modifiedAt": "2026-11-19T16:51:38.603Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=VIPIaFtg4F",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/vsa2nt04yu.json added

+++ b/reviews/openreview/js7ariv05d/notes/vsa2nt04yu.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "vSa2NT04yu",
+ "replyTo": "mdgcwK7Jra",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank You for the Feedback",
+ "comment": "Thank you for reconsidering and raising your score. We will clearly document this setting in the revised paper. If an official W4A4 implementation becomes available, we will also add a direct comparison."
+ },
+ "createdAt": "2026-08-03T16:43:34.198Z",
+ "modifiedAt": "2026-11-19T16:51:37.983Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=vSa2NT04yu",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/vtgmor98q8.json added

+++ b/reviews/openreview/js7ariv05d/notes/vtgmor98q8.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "vTgmOR98q8",
+ "replyTo": "ZR18c91IUd",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Additional Evidence on the ParoQuant Comparison",
+ "comment": "In our previous response, we clarified that the submitted baseline applies the RAC-trained rotation and scaling **before running the complete ParoQuant procedure**. It does not replace ParoQuant’s optimized transform. We now provide additional evidence using ParoQuant’s released checkpoint and a faithful W4A4 reproduction.\n\nWe first evaluated the released ParoQuant Qwen3-8B checkpoint under W4A4. Directly quantizing its activations causes the model to collapse. Even when we use the complete W4A4 formulation (Eq.10) in ParoQuant Appendix A.3, the perplexity remains high, as shown in Table 1. **This result shows that the released ParoQuant checkpoint does not provide competitive W4A4 performance in our evaluation.** However, its training and calibration settings are not aligned with ours, so we treat this only as an initial observation rather than a matched comparison.\n\n**Table 1. W4A4 evaluation of the released ParoQuant Qwen3-8B checkpoint.**\n\n| Evaluation method | WikiText2 PPL ↓ | C4 PPL ↓ |\n|---|---:|---:|\n| Direct activation quantization | 44972.40 | 45600.60 |\n| ParoQuant Appendix A.3 formulation | 25.71 | 37.12 |\n\nWe then **performed a matched comparison by retraining ParoQuant using its official code and complete W4A4 method**, including its optimized scaled pairwise rotation and activation-side transform. **We aligned the quantization setting, calibration data, token budget, and optimization budget with ClusQuant.**\n\n**Table 2. Perplexity under matched W4A4 settings.**\n\n| Model | Method | WikiText2 PPL ↓ | C4 PPL ↓ |\n|---|---|---:|---:|\n| Qwen3-4B-Thinking | BF16 | 11.478 | 18.391 |\n| Qwen3-4B-Thinking | **ParoQuant, Reproduction** | **40.310** | **54.510** |\n| Qwen3-4B-Thinking | ParoQuant + RAC, submission setting | 14.771 | 23.070 |\n| Qwen3-4B-Thinking | **ClusQuant** | **12.890** | **20.538** |\n| Qwen3-8B | BF16 | 10.047 | 15.439 |\n| Qwen3-8B | **ParoQuant, Reproduction** | **33.060** | **46.950** |\n| Qwen3-8B | ParoQuant + RAC, submission setting | 12.830 | 19.260 |\n| Qwen3-8B | **ClusQuant** | **11.362** | **17.177** |\n\n**The matched ParoQuant reproduction has substantially higher perplexity than ClusQuant on both models.** Adding the RAC transform greatly improves ParoQuant, which shows that our submitted setting strengthens the baseline while preserving ParoQuant’s own optimized transform. ClusQuant still achieves the best W4A4 perplexity.\n\nDue to limited computing resources and the short rebuttal period, we could not complete the long-generation evaluation for these newly trained checkpoints. Perplexity does not replace downstream accuracy, but the consistent gaps across two datasets and two model sizes provide direct evidence of W4A4 quantization fidelity.\n\nFinally, we evaluate our ParoQuant reproduction under its native W4A16 setting.\n\n**Table 3. ParoQuant reproduction under W4A16.**\n\n| Model | BF16 WikiText2 / C4 | ParoQuant W4A16 WikiText2 / C4 | Relative degradation |\n|---|---:|---:|---:|\n| Qwen3-4B-Thinking | 11.478 / 18.391 | 12.29 / 18.68 | +7.1% / +1.6% |\n| Qwen3-8B | 10.047 / 15.439 | 10.63 / 15.54 | +5.8% / +0.7% |\n\nThe W4A16 results remain much closer to BF16 than the W4A4 results, providing an additional sanity check for our reproduction. On WikiText2, our result is close to the W4A16 performance reported by ParoQuant. The difference on C4 should be interpreted in light of the different calibration data. Our non-RAC calibration set contains only WikiText2, whereas ParoQuant uses a much larger mixed calibration set that includes C4.\n\nBased on these experiments, we reiterate that **RAC strengthens ParoQuant rather than weakening it**. Our submitted baseline preserves ParoQuant’s complete optimized transform and gives it the additional benefit of RAC. We therefore consider the submitted setting a fairer and stronger ParoQuant baseline for W4A4. **ClusQuant outperforms both the faithful original method and this strengthened baseline.** We hope these additional controlled experiments address the reviewer’s remaining concern, and we respectfully ask the reviewer to consider this new evidence and reconsider the evaluation."
+ },
+ "createdAt": "2026-08-03T16:09:34.085Z",
+ "modifiedAt": "2026-11-19T16:51:38.098Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=vTgmOR98q8",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/x2xrw1jve1.json added

+++ b/reviews/openreview/js7ariv05d/notes/x2xrw1jve1.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "X2xRw1jve1",
+ "replyTo": "sYKlqWEifs",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Question 3",
+ "comment": "We profile the ClusQuant kernel using Nsight Compute (NVIDIA's GPU profiling tool) on an A100 GPU using Qwen3-4B-Thinking model. Following the LUT-based kernel described in Section 3.5, we measure the kernel performance with W4A4 setting and compare it with the FP16 GEMM baseline.\n\nFirst, we analyze the kernel memory overhead. Across all layers in Qwen3-4B-Thinking, ClusQuant reduces global memory (GPU off-chip memory) read traffic by an average of 71%, because weights are stored as compact cluster indices instead of FP16 values and activations are processed in their packed 4-bit representation. The lookup table (LUT) occupies only 8 KB of shared memory, the small on-chip memory inside each GPU Streaming Multiprocessor (SM), which is **less than 5% of the 164 KB shared memory** available on an A100 SM. Overall, the additional kernel memory overhead (mainly the LUT) is negligible compared with the memory reduction obtained from clustered low-bit weights.\n\nSecond, we analyze the batch size sensitivity of the ClusQuant GPU kernel. We evaluate the ClusQuant kernel on the Qwen3-4B-Thinking model on an A6000 GPU under the same three workload configurations used for the system evaluation in Section 4.2, namely WikiText2 with (prefill, decode) lengths of (1024, 100), GSM8K with (100, 4000), and AIME25 with (150, 6000). For each configuration we sweep the batch size from 1 to 16 and report the end-to-end speedup over the FP16 baseline in the table below. \n\nTable 4. End-to-end speedup over FP16 across different batch sizes.\n| Batch size | WikiText2 | GSM8K | AIME25 |\n|---:|---:|---:|---:|\n| 1 | 2.31× | 2.45× | 2.48× |\n| 4 | 2.32× | 2.46× | 2.48× |\n| 8 | 2.30× | 2.44× | 2.46× |\n| 16 | 2.28× | 2.43× | 2.45× |\n\nAs the batch size increases, the amount of weight and activation data processed by both the FP16 baseline and ClusQuant grows proportionally. However, ClusQuant consistently represents weights using compact cluster indices and activations using 4-bit quantization indices, substantially reducing memory traffic for both operands. In addition, arithmetic multiplications are replaced with efficient LUT lookups. Since these advantages scale proportionally with batch size, the relative speedup remains nearly constant across different batch sizes. \n\nLastly, we analyze the pre-padding impact. After clustering, each weight is represented by a small integer index indicating its assigned centroid, while each activation is represented by a 4-bit quantization index. Since these indices are much smaller than full-precision values, multiple indices are packed into a 32-bit word to reduce memory traffic. The number of weight indices per word depends on the cluster number K: 10, 8, and 6 indices for K=8, 16, and 32, respectively, while each 32-bit word always stores 8 activation indices. During matrix multiplication, the kernel reads one word of weight indices and one word of activation indices at a time. To avoid partially filled words, each kernel iteration processes a fixed-size block of elements. The block size is chosen as the least common multiple of the numbers of weight and activation indices packed into a 32-bit word, ensuring that both streams remain word-aligned. If the reduction dimension is not an exact multiple of the corresponding block size, a small number of zero-valued elements are appended to complete the final block. Since Adaptive Cluster Allocation selects K differently for each matrix, different layers may require different processing block sizes. We therefore evaluate the padding overhead for all three cluster numbers across every reduction dimension appearing in Qwen3-4B-Thinking, Qwen3-8B, and Phi-4-Reasoning. The padding ratio is defined as the number of padded elements divided by the original reduction dimension. \n\nTable 5. Pre-padding ratios across reduction dimensions and cluster sizes.\n| Reduction dimension | \\(K=8\\) | \\(K=16\\) | \\(K=32\\) |\n|---:|---:|---:|---:|\n| 2560 | 0.00% | 0.00% | 0.31% |\n| 4096 | 0.59% | 0.00% | 0.20% |\n| 5120 | 0.00% | 0.00% | 0.31% |\n| 9278 | 0.33% | 0.00% | 0.16% |\n| 12288 | 0.26% | 0.00% | 0.00% |\n| 17920 | 0.00% | 0.00% | 0.04% |\n\n**The worst-case padding ratio across all layers, models, and cluster numbers is only 0.59%, while the average padding ratio remains below 0.2%**, demonstrating that pre-padding introduces negligible kernel overhead."
+ },
+ "createdAt": "2026-07-29T04:48:10.694Z",
+ "modifiedAt": "2026-11-19T16:51:38.552Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=X2xRw1jve1",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/xjb3nyhsks.json added

+++ b/reviews/openreview/js7ariv05d/notes/xjb3nyhsks.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "xJb3nYhsks",
+ "replyTo": "XpehB2xTd6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Weakness 2",
+ "comment": "Thanks for pointing out this question. **We observe the early-stage fluctuation across multiple reasoning models and datasets, while other non-reasoning models do not show the same pattern.** Beyond Qwen3-4B-Thinking on GSM8K, we observe the same trend in GPT-OSS-20B and Qwen3-30B-A3B-Thinking. We also observe it on MATH-500 and the more difficult AIME problems using the Qwen3-4B-Thinking model. \n\nTable 1. Early-stage activation fluctuation across reasoning models and datasets. \n| Comparison | Setting | Peak step | Stabilization step | Peak over stabilization |\n|---|---|---:|---:|---:|\n| Model | GPT-OSS-20B | 0 | 23 | +24.1% |\n| Model | Qwen3-30B-A3B-Thinking | 0 | 34 | +38.7% |\n| Dataset | MATH-500 | 0 | 26 | +17.1% |\n| Dataset | AIME24 | 5 | 39 | +20.5% |\n\nWe further compare Qwen3-4B-Thinking with the standard Qwen3-4B model. We also compare the reasoning and non-reasoning modes of the same Qwen3-8B model. In both comparisons, non-reasoning generation does not show the same concentration of activation fluctuation in the early stage. Together with Table 1, these results show that the pattern is linked to explicit reasoning behavior rather than general early decoding.\n\n**The token-length sweep shows that 256 tokens is an empirically selected operating point, not a universal constant.** Table 2 reports the complete results from 64 to 768 calibration tokens.\n\nTable 2. Reasoning accuracy under different early-token calibration lengths.\n| Completion length | Math-500 | GSM8K | AIME25@Pass1 | AIME26@Pass1 | HumanEval | LiveCodeBench | Average |\n|---:|---:|---:|---:|---:|---:|---:|---:|\n| 64 | 0.912 | 0.923 | 0.358 | 0.354 | 0.884 | 0.392 | 0.637 |\n| 128 | 0.936 | 0.939 | 0.521 | 0.567 | 0.933 | 0.549 | 0.741 |\n| 256 | 0.950 | 0.938 | 0.563 | 0.613 | 0.945 | 0.614 | 0.770 |\n| 512 | 0.938 | 0.938 | 0.529 | 0.571 | 0.915 | 0.591 | 0.747 |\n| 768 | 0.944 | 0.941 | 0.467 | 0.496 | 0.921 | 0.560 | 0.721 |\n\nAs shown in Table 2, the average increases from 0.637 at 64 tokens to 0.770 at 256 tokens, then decreases to 0.721 at 768 tokens. Later tokens have weaker and different sensitivity patterns. Including the full trace gives less relative weight to the early high-sensitivity states. This explains why using more calibration tokens does not always improve performance. RAC uses measured numerical sensitivity rather than fixed semantic labels such as exploration, self-correction, or conclusion. \nAs for RL artifact, conceptually, early reasoning tokens correspond to the stage in which the model interprets the problem and selects among possible solution trajectories. Before a trajectory is established, its internal states can therefore vary more sharply from token to token. RAC is designed for this observed numerical behavior and does not depend on whether it arises from RL, supervised reasoning data, or another post-training stage. Isolating the causal role of RL would require matched checkpoints before and after reasoning-oriented RL. We therefore claim an association with explicit reasoning behavior, rather than causality from RL.\n\nFinally, we also directly examined whether this pattern appears in non-reasoning generation. Compared with Qwen3-4B-Thinking used in our main experiments, the **standard Qwen3-4B model does not exhibit the same early-stage concentration of activation fluctuation and quantization sensitivity**. We further compare the **reasoning and non-reasoning modes of the same Qwen3-8B model and again observe this trend only in the reasoning mode.** Together, these cross-model and within-model comparisons indicate that this pattern is associated with reasoning generation rather than being a general property of early decoding."
+ },
+ "createdAt": "2026-07-29T04:34:48.738Z",
+ "modifiedAt": "2026-11-19T16:51:38.649Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=xJb3nYhsks",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/js7ariv05d/notes/zr18c91iud.json added

+++ b/reviews/openreview/js7ariv05d/notes/zr18c91iud.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "ZR18c91IUd",
+ "replyTo": "RqAZua3GTR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Reponse to ParoQuant Concern",
+ "comment": "Thank you for raising this point. Our previous wording was ambiguous. **We did not replace ParoQuant’s optimized transform.** We first applied the RAC-trained rotation and scaling and then ran the ParoQuant W4A4 procedure, including its own optimized scaled pairwise rotation and GPTQ-based weight recovery.\n\n**We added the RAC-trained transform because the original ParoQuant method is primarily designed for W4A16.** Appendix A.3 in ParoQuant explicitly states that ParoQuant was not specifically tuned for W4A4 and that its W4A4 results may not be optimal. Tables A2 and A3 also show that it does not consistently match methods designed for W4A4. We observed the same limitation when directly applying its W4A4 configuration. **Given ParoQuant’s W4A16-specific design, we believe that directly comparing it under W4A4 without adding the RAC-based transform would instead be unfair to ParoQuant.** We therefore provide ParoQuant with the same RAC-trained rotation and scaling used by ClusQuant before running its complete method. This gives ParoQuant a stronger W4A4 starting point and controls the effect of reasoning-aware preprocessing across the comparison.\n\nWe will revise the description and label this setting as **ParoQuant + RAC transform** to make the evaluation protocol explicit."
+ },
+ "createdAt": "2026-08-02T04:09:15.534Z",
+ "modifiedAt": "2026-11-19T16:51:38.070Z",
+ "url": "https://openreview.net/forum?id=jS7aRiV05d&noteId=ZR18c91IUd",
+ "license": "CC-BY-4.0"
+}