pCoMole: Pareto-Constrained Molecule Editing with Discrete Flows
Update NeurIPS 2026 submission IUuHJ0x69N: 11 notes
@openreview[bot] · 2026-11-24 15:48 UTC · 50263f17110b ·
reviews/openreview/iuuhj0x69n/notes/06nkq7ri9l.json added
+++ b/reviews/openreview/iuuhj0x69n/notes/06nkq7ri9l.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "06nKq7ri9L",+ "replyTo": "Sx8d9BtSvX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you very much for your thoughtful follow-up and for recognizing that our independent validation and runtime analyses addressed your main questions. We also appreciate your positive reassessment of the contribution type and your continued view that this is good work.\n\nSince you indicated that your score will remain unchanged, could you kindly let us know whether any specific remaining concern or missing evidence currently prevents a higher score? We would be grateful for the opportunity to provide a focused clarification or additional analysis if helpful. If your assessment is already final, we fully understand and sincerely appreciate your consideration."+ },+ "createdAt": "2026-07-30T23:05:59.454Z",+ "modifiedAt": "2026-11-19T17:08:49.791Z",+ "url": "https://openreview.net/forum?id=IUuHJ0x69N¬eId=06nKq7ri9L",+ "license": "CC-BY-4.0"+}
reviews/openreview/iuuhj0x69n/notes/3i59mtuqyn.json modified
+++ b/reviews/openreview/iuuhj0x69n/notes/3i59mtuqyn.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair o9gt","content": {- "metareview": "This paper proposes a discrete flow-matching framework for multi-objective biomolecular sequence editing under hard feasibility constraints. While reviewers acknowledge the paper's theoretical formulation and clear presentation, they raise serious concerns regarding the empirical evaluation: (1) relying on the same learned oracles for both steering and evaluation creates a strong risk of off-distribution extrapolation, and the work lacks validation from independent oracles or wet-lab experiments; (2) the quantitative results lack statistical variance reporting and leave key evaluation metrics and fallback behaviors under-specified."+ "metareview": "This paper proposes a discrete flow-matching framework for multi-objective biomolecular sequence editing under hard feasibility constraints. While reviewers acknowledge the paper's theoretical formulation and clear presentation, they raise serious concerns regarding the empirical evaluation: (1) relying on the same learned oracles for both steering and evaluation creates a strong risk of off-distribution extrapolation, and the work lacks validation from independent oracles or wet-lab experiments; (2) the quantitative results lack statistical variance reporting and leave key evaluation metrics and fallback behaviors under-specified.",+ "final_justification": "I would like to thank the authors for their thorough rebuttal. It successfully addressed the reviewers' primary concerns, and all reviewers are now in favor of accepting this work."},"createdAt": "2026-07-20T00:46:04.642Z",- "modifiedAt": "2026-11-18T15:21:56.337Z",+ "modifiedAt": "2026-11-19T05:01:11.433Z","url": "https://openreview.net/forum?id=IUuHJ0x69N¬eId=3I59mTUqyN","license": "CC-BY-4.0"}
reviews/openreview/iuuhj0x69n/notes/f4cgybxoxl.json added
+++ b/reviews/openreview/iuuhj0x69n/notes/f4cgybxoxl.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "F4CGYBXoxL",+ "replyTo": "qDjM9sUUbr",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank the reviewer for the thoughtful follow-up, for recognizing that our rebuttal addressed the original concerns, and for positively revising their assessment. We also appreciate these questions on trajectory efficiency and shrinkage control.\n\n> 1. Trajectory efficiency and rejection-like behavior\n\nThank you for this important question. Frequent no-selectable steps reveal a genuine **sample-efficiency limitation** when feasible continuations have low probability under the pretrained Edit Flow. Retaining the current state is nevertheless an intentional **safeguard** against forcing an edit with no sampled evidence of terminal feasibility.\n\nFor a state–candidate pair $(x_t,a)$, let $p_t=\\Pr(X_1\\in\\mathcal F\\mid x_t,a)$. With $R$ rollouts, a feasible continuation is observed with probability $1-(1-p_t)^R$. Thus, pCoMole assumes useful feasible terminals have non-negligible support under the base Edit Flow from some reachable states. This is a minimal-information assumption: it requires neither gradients, a task-specific feasibility model, nor offline feasible data.\n\nWe also agree that feasibility gating is **rejection-like** because infeasible rollouts receive zero value and may consume substantial computation. However, pCoMole does more than terminal rejection: its candidate-conditioned rollouts estimate preference-specific multi-objective continuation values and use them to steer subsequent edits. To test whether this steering provides value beyond matched-budget rejection, we conducted a preliminary GFP comparison using the same base Edit Flow, constraints, objectives, and total oracle-call budget.\n\n**Table R5. Matched-budget GFP comparison over four paired runs**\n\n|Method|Rep. 1|Rep. 2|Rep. 3|Rep. 4|Mean ± SD|Paired wins|\n|-|:-:|:-:|:-:|:-:|:-:|:-:|\n|pCoMole|53.57|44.29|53.22|63.61|53.68 ± 7.89|3/4|\n|Unguided Edit Flow + rejection|35.96|56.84|50.36|50.25|48.35 ± 8.82|1/4|\n\nBoth methods found feasible exact-length designs in all four runs. pCoMole achieved higher returned utility in three of four paired runs and a higher mean utility, although the small sample size makes this a diagnostic rather than a statistically conclusive comparison.\n\nFinally, the reported 0% complete-run failure rate does not count the unchanged input as success: runs with no feasible edited terminal are failures, and all reported runs produced feasible designs distinct from the input. Future work could use a rollout archive and lightweight online reachability model to pre-screen unlikely candidates and allocate rollouts toward promising or uncertain ones. This could reduce wasted evaluations when feasible mass is small but observable, but cannot remove the support requirement.\n\n> 2. Shrinkage variability and length control\n\nThank you for raising this point. The reported $43[22,68]$ summary aggregates **absolute SMILES-token reductions** across three therapeutic binders with substantially different initial lengths; it is therefore not the within-target IQR for any single binder or run. Table R4 reports the observed range for each target, together with the normalized reduction.\n\n**Table R4. Per-target SMILES-token reduction over 100 trajectories**\n\n|Target|Initial length|Final-length range|Reduction range, tokens (%)|\n|-|:-:|:-:|:-:|\n|1AYC|59|29–58|1–30 (1.7–50.8%)|\n|1B8Q|51|25–50|1–26 (2.0–51.0%)|\n|1DDV|41|20–40|1–21 (2.4–51.2%)|\n|1E6I|43|21–42|1–22 (2.3–51.2%)|\n|2LTV|85|42–84|1–43 (1.2–50.6%)|\n|2Q8Y|72|36–71|1–36 (1.4–50.0%)|\n|3IDJ|50|25–49|1–25 (2.0–50.0%)|\n|4GNE|54|27–53|1–27 (1.9–50.0%)|\n|5AZ8|80|41–79|1–39 (1.2–48.8%)|\n|5KRI|105|53–104|1–52 (1.0–49.5%)|\n|5M02|61|30–60|1–31 (1.6–50.8%)|\n|6MLC|45|22–44|1–23 (2.2–51.1%)|\n|7JVS|79|39–78|1–40 (1.3–50.6%)|\n|7LUL|70|35–69|1–35 (1.4–50.0%)|\n|8CN1|30|15–29|1–15 (3.3–50.0%)|\n|PTH1R|259|158–258|1–101 (0.4–39.0%)|\n|p53|170|86–169|1–84 (0.6–49.4%)|\n|GLP-1R|248|124–243|5–124 (2.0–50.0%)|\n\nFor peptidomimetics, we deliberately used the broad terminal constraint $\\left\\lfloor L_0/2\\right\\rfloor\\leq L<L_0$, which requires shortening while preventing collapse beyond approximately 50%. Within this interval, pCoMole jointly optimizes length reduction and six additional properties, so different feasible multi-objective trade-offs can yield different final lengths.\n\nThis variability reflects the chosen task specification rather than an intrinsic lack of length control. pCoMole can enforce either an exact length as in GFP, or a narrower user-specified interval such as $(1-r_{\\max})L_0\\leq L\\leq(1-r_{\\min})L_0$. Tighter constraints would provide more precise shrinkage control, although they may reduce feasible reachability or require stronger trade-offs with the other objectives.\n\nWe hope these clarifications and additional analyses address the remaining concerns, and we would be grateful if the reviewer would consider increasing the rating. If any concern remains, we would greatly appreciate guidance on what additional clarification would be most helpful."+ },+ "createdAt": "2026-08-01T03:18:19.968Z",+ "modifiedAt": "2026-11-19T17:08:50.110Z",+ "url": "https://openreview.net/forum?id=IUuHJ0x69N¬eId=F4CGYBXoxL",+ "license": "CC-BY-4.0"+}
reviews/openreview/iuuhj0x69n/notes/fn3m0x01jl.json added
+++ b/reviews/openreview/iuuhj0x69n/notes/fn3m0x01jl.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Fn3m0X01jl",+ "replyTo": "3I59mTUqyN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Final Author Summary: Reviewer Consensus and Rebuttal Outcomes",+ "comment": "Dear Area Chair,\n\nAs the discussion period closes, we summarize the final reviewer record and how the rebuttal addressed every concern in the preliminary meta-review.\n\nThe final scores are **5, 4, and 4**. **All three reviewers support acceptance.**\n\n- **Reviewer rVPi** raised the score from 3 to **5**, stated that all original concerns were addressed, praised the theoretical, computational, and wet-lab evidence, and reported having no further questions.\n- **Reviewer cHFo** stated that the concerns were addressed and updated the assessment to **4**.\n- **Reviewer ffWP** stated that the independent validation and runtime analyses addressed the main questions, continued to describe the submission as good work, and maintained a supportive **4** with confidence 4.\n\nThis record followed substantial discussion, targeted new experiments, and direct reviewer reassessment.\n\n## Central Meta-Review Concern: Independent Validation\n\nThe preliminary meta-review identified oracle reuse and the absence of independent or experimental validation as the central weakness. We addressed this at three levels:\n\n- **Wet-lab GFP validation:** Two pCoMole-designed eGFPs retained clear green fluorescence in BL21 cells after being shortened from 239 to 229 amino acids through 10 deletions. The negative control showed no comparable signal.\n- **Held-out Cas9 evaluation:** CICERO, never used during generation, confirmed PAM preservation. Guidance increased CICERO exact matches from **4% to 88% for St3Cas9** and from **20% to 72% for GeoCas9**.\n- **Independent peptidomimetic evaluation:** Boltz-2 and AutoDock Vina were used only after generation. They supported favorable binding and showed that edited binders retained parental binding pockets and overlapping interface residues.\n\n## Statistical Reliability and Candidate-Level Behavior\n\nThe meta-review also requested variance reporting and clearer evaluation definitions. We added:\n\n- **95% confidence intervals** for the principal GFP, Cas9, and peptidomimetic results\n- **Median and IQR analyses** showing that gains are distributed across candidates rather than driven by isolated outliers\n- Exact definitions and denominators for validity, brightness, excitation error, PAM preservation, and chemical validity\n- Explicit sampling units across tasks\n\nThe intervals preserve the main conclusions across GFP, four Cas9 orthologs, and 15 peptidomimetic targets.\n\n## Rollout Failures, Fallbacks, and Efficiency\n\nWe fully specified the rollout behavior:\n\n- Candidates with no feasible rollout receive zero value\n- If no candidate is selectable, the current state is retained\n- If an entire run finds no feasible edited terminal, the input is returned and the run is counted as a failure\n- Complete-run failures reported as 0% indicate **all runs successfully produced edited feasible outputs** distinct from the input\n\nWe also decomposed runtime and showed that rollout simulation and terminal-oracle evaluation dominate cost. These stages are parallelizable across candidate-rollout pairs.\n\nIn response to Reviewer **rVPi**’s follow-up, we compared pCoMole with matched-budget unguided Edit Flow plus rejection. pCoMole achieved higher returned utility in **3 of 4 paired runs** and a higher mean utility, supporting the value of candidate-conditioned continuation estimates beyond terminal rejection alone.\n\n## Methodological Clarifications\n\nWe also clarified:\n\n- Why terminal feasibility preserves coordinated edit paths that may temporarily leave the feasible region\n- Why pCoMole differs from multi-objective MCTS by scalarizing before rollout estimation\n- How cost scales with objective evaluation rather than combinatorially with the number of objectives\n- How vocabulary size affects proposal logits without increasing the fixed candidate or rollout budget\n- How users can enforce exact lengths, as in GFP, or narrower intervals for tighter shrinkage control\n- Why RayGun and SCISOR are shrinkage baselines rather than objective-matched methods\n- Why Table 6 is an incumbent-editing case study rather than a generative baseline comparison\n\n## Final Request\n\nThe preliminary meta-review identified two main issues: **independent biological validation** and **under-specified statistical and fallback behavior**. Both have now been directly resolved through wet-lab fluorescence experiments, held-out computational evaluators, confidence intervals, candidate-level distributions, explicit rollout statistics, runtime decomposition, and detailed methodological clarification.\n\nMost importantly, the reviewers engaged with these additions and updated their assessments. The final scores are **5, 4, and 4**, with all three reviewers supporting acceptance and no unresolved technical objection remaining in the discussion. We respectfully ask that the final decision reflect this strong reviewer consensus and the substantially strengthened empirical record. We sincerely hope pCoMole will be accepted.\n\nThank you,\n\nThe Authors"+ },+ "createdAt": "2026-08-03T20:29:16.252Z",+ "modifiedAt": "2026-11-19T17:08:49.449Z",+ "url": "https://openreview.net/forum?id=IUuHJ0x69N¬eId=Fn3m0X01jl",+ "license": "CC-BY-4.0"+}
reviews/openreview/iuuhj0x69n/notes/icauu1ujxk.json added
+++ b/reviews/openreview/iuuhj0x69n/notes/icauu1ujxk.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "iCAuU1UjXK",+ "replyTo": "XG5swEpfZJ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer rVPi",+ "content": {+ "title": "Response to Authors' Rebuttal #2",+ "comment": "I thank the authors for the additional results and explanations on my second review.\n\n### Summary of authors' response:\n- Justified the **intentional fallback design** with a short probabilistic explanation;\n- **Nuanced** pCoMole's rejection-like behavior and provided pilot results to (re-)demonstrate its ability to steer edits throughout rollouts. The authors also discussed future directions on how to make future versions of pCoMole more efficient;\n- **Clarified** ablation from their response to reviewer *cHFo* on expected length variability controllability.\n\nGiven the limited time, I praise the authors' efforts on addressing all questions by providing both theoretical, experimental (be they *in silico* or *wet-lab*) and quantitative elements to the discussion.\n\nI do not have further questions and I am happy to **raise my score** from 3 to 5.\n\nI expect this already-dense manuscript to become denser (because positively extensive) and it may be challenging for unfamiliar audience to apprehend it.\nMy final suggestion is to take more time to polish the manuscript and re-organize the content to facilitate its read (e.g. from the main body, by better pointing to appendices and refining discussion sections as hinted in the first review)."+ },+ "createdAt": "2026-08-02T10:08:38.868Z",+ "modifiedAt": "2026-11-19T17:08:49.780Z",+ "url": "https://openreview.net/forum?id=IUuHJ0x69N¬eId=iCAuU1UjXK",+ "license": "CC-BY-4.0"+}
reviews/openreview/iuuhj0x69n/notes/jleelor1cx.json added
+++ b/reviews/openreview/iuuhj0x69n/notes/jleelor1cx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "jLEElOr1cx",+ "replyTo": "8E0Mvligl5",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer cHFo",+ "content": {+ "comment": "Thank you for answering the questions and addressing the concern.\n\nI have updated my assessment accordingly."+ },+ "createdAt": "2026-08-02T20:28:27.451Z",+ "modifiedAt": "2026-11-19T17:08:49.456Z",+ "url": "https://openreview.net/forum?id=IUuHJ0x69N¬eId=jLEElOr1cx",+ "license": "CC-BY-4.0"+}
reviews/openreview/iuuhj0x69n/notes/p3qpfmnvnm.json added
+++ b/reviews/openreview/iuuhj0x69n/notes/p3qpfmnvnm.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "P3QPfMnVnM",+ "replyTo": "jLEElOr1cx",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear reviewer cHFo,\n\nThank you very much for updating your assessment and raising the score. We sincerely appreciate your time and thoughtful feedback.\n\nThank you again,\n\nThe Authors"+ },+ "createdAt": "2026-08-02T21:11:08.627Z",+ "modifiedAt": "2026-11-19T17:08:49.772Z",+ "url": "https://openreview.net/forum?id=IUuHJ0x69N¬eId=P3QPfMnVnM",+ "license": "CC-BY-4.0"+}
reviews/openreview/iuuhj0x69n/notes/qdjm9suubr.json added
+++ b/reviews/openreview/iuuhj0x69n/notes/qdjm9suubr.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "qDjM9sUUbr",+ "replyTo": "li6xmK8QPo",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer rVPi",+ "content": {+ "title": "Response to Authors' Rebuttal #1",+ "comment": "I thank the authors for their thorough first rebuttal.\nI sincerely appreciate that authors took the time to address all underlined weaknesses and questions initially raised:\n\n### Summary of authors' response:\n- **Independent validation** (W1a/Q3) - also raised by reviewer ffWP: In response to the original concern of oracle exploitation, the authors used held-out computational predictors not involved in the guidance loop (CICERO for Cas9; Boltz-2 and AutoDock Vina for peptidomimetics). Notably, wet-lab experimental validation on generated GFPs retaining green fluorescence in BL21 cells particularly stands out. \n- **Evaluation Fairness & Scope of Baselines** (W1b & W2): The authors transparently agreed that Table 6 is not a generative baseline comparison and reframed their analysis.\n- **Statistical Significance** (W3/Q1) - also raised by reviewer cHFo: The authors resolved variance concerns by calculating 95% confidence intervals over 100 GFP trajectories, 50 Cas9 trajectories, and 100 peptidomimetic trajectories.\n- **Objective Scaling During Rollout** (Q2): The authors provided a theoretical distinction from multi-objective MCTS, explaining that because pCoMole scalarizes before rollout, computational cost scales strictly with the evaluation of additional objectives, rather than combinatorially with the number of objectives.\n\n### Additional questions:\nI am overall satisfied with the answers provided to my own review. \nHowever after reading the rebuttal discussion of other reviewers, new questions arise:\n1. **Trajectory Efficiency** (raised by reviewer cHFo): The authors' response to Reviewer cHFo regarding \"infeasible rollouts\" (Q2 + Table R2) reveals inefficiency in the sampling process: for Cas9 and Peptidomimetics, between 31% and 55% of generation steps result in no selectable candidates (i.e., all rollouts lead to infeasible terminals) and rely on fallback mechanisms. Therefore, doesn't the 0% complete-run failure rate rely on retaining current states? If the generation is supposedly steered but the edit flow only exhibits few feasible paths, doesn't the guidance mechanism act more like a computationally expensive brute-force rejection sampler? More generally, how would you further improve pCoMole to escape those inefficient steps?\n2. **Variance in Shrinkage Outcome** (raised by reviewer cHFo): The authors provided median and interquartile ranges (W1b. + Table R1c) of peptidomimetic candidate generation. The length reduction of therapeutic examples report a range of an IQR of [22.0, 68.0] which is a relatively large range and could limit the guarantee of how much shrinkage one could expect from a given run. How do you attribute this tradeoff between target length controllability and \"broadly distributed gains\"?\n\nI am also changing my evaluation type from \"General\" to \"Use-Inspired\" to better assess the domain-specificity of the work, and positively adjusting Quality/Clarity/Significance/Originality ratings."+ },+ "createdAt": "2026-07-30T12:24:20.953Z",+ "modifiedAt": "2026-11-19T17:08:49.796Z",+ "url": "https://openreview.net/forum?id=IUuHJ0x69N¬eId=qDjM9sUUbr",+ "license": "CC-BY-4.0"+}
reviews/openreview/iuuhj0x69n/notes/rpvwsjjdff.json added
+++ b/reviews/openreview/iuuhj0x69n/notes/rpvwsjjdff.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "rPvwSJjDFF",+ "replyTo": "8E0Mvligl5",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer cHFo,\n\nThank you again for your careful review. Since the discussion period is ending soon, we wanted to ask whether you had a chance to consider the new wet-lab GFP validation, candidate-level median and IQR analyses, confidence intervals across all three tasks, explicit rollout-failure statistics, and clarified validity and averaging definitions. Two shortened pCoMole GFP designs retained clear fluorescence in BL21 cells, directly addressing the central concern that the evidence was only computational. We would be very grateful for any feedback and, if these additions resolve your concerns, for raising both your score and confidence to support acceptance of this work!\n\nThank you,\nThe Authors"+ },+ "createdAt": "2026-08-01T19:54:36.162Z",+ "modifiedAt": "2026-11-19T17:08:49.768Z",+ "url": "https://openreview.net/forum?id=IUuHJ0x69N¬eId=rPvwSJjDFF",+ "license": "CC-BY-4.0"+}
reviews/openreview/iuuhj0x69n/notes/sx8d9btsvx.json added
+++ b/reviews/openreview/iuuhj0x69n/notes/sx8d9btsvx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Sx8d9BtSvX",+ "replyTo": "W3e1829SnS",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer ffWP",+ "content": {+ "comment": "Thank you for the additional experiments and clarifications. The independent validation explanations and runtime breakdown in Table R2 were helpful and addressed my main questions. I have also updated the contribution type to Use-inspired and revised my assessment accordingly. I continue to view this as good work and will keep my score unchanged."+ },+ "createdAt": "2026-07-30T18:07:22.101Z",+ "modifiedAt": "2026-11-19T17:08:49.798Z",+ "url": "https://openreview.net/forum?id=IUuHJ0x69N¬eId=Sx8d9BtSvX",+ "license": "CC-BY-4.0"+}
reviews/openreview/iuuhj0x69n/notes/umug9eyqum.json added
+++ b/reviews/openreview/iuuhj0x69n/notes/umug9eyqum.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "umuG9eYquM",+ "replyTo": "F4CGYBXoxL",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear reviewer rVPi,\n\nThank you very much for your thoughtful follow-up, careful engagement throughout the discussion, and decision to raise your score. We deeply appreciate your final suggestion and will revise the manuscript to reflect our discussion.\n\nThank you again, \n\nThe Authors"+ },+ "createdAt": "2026-08-02T17:14:42.732Z",+ "modifiedAt": "2026-11-19T17:08:49.454Z",+ "url": "https://openreview.net/forum?id=IUuHJ0x69N¬eId=umuG9eYquM",+ "license": "CC-BY-4.0"+}