Provable Selective Auto-labeling with Reliability Guarantees
Update NeurIPS 2026 submission EEhIsOCdWt: 10 notes
@openreview[bot] · 2026-11-24 15:47 UTC · cb2a6710d6d2 ·
reviews/openreview/eehisocdwt/notes/9hguhh2njn.json added
+++ b/reviews/openreview/eehisocdwt/notes/9hguhh2njn.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "9HGuhh2njN",+ "replyTo": "TsUVj64GIH",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the insightful comments. Please find our response below:\n\n**1. Scope of the FLR guarantee [W1, Q1]**\n\nWe clarify that our FLR guarantee is unconditional: it ensures $FLR \\leq \\alpha$, where the expectation is over the randomness of the calibration and test samples. It does not guarantee FLR control conditional on a realized calibration set, nor does it provide a high-probability bound of the FLP.\n\nTo show what users can expect for a fixed dataset, we conduct a new experiment. Specifically, we run Conformal Labeling on MMLU with Qwen3-32B at $\\alpha=0.1$. We report $P(\\mathrm{FLP}>\\alpha)$ and the 90th percentile of FLP over 1,000 repetitions with different calibration sizes.\n\n| $n$ | $P(\\mathrm{FLP}>\\alpha)$ (%) | 90th pct. FLP (%) |\n|-|-:|-:|\n| 10 | 42.19 | 21.44 |\n| 50 | 44.50 | 15.71 |\n| 100 | 46.00 | 13.85 |\n| 1,000 | 48.30 | 11.44 |\n\nThe result shows that as $n$ increases, $P(\\mathrm{FLP}>\\alpha)$ approaches 50% because the realized FLP becomes increasingly concentrated around $\\alpha$. Meanwhile, the 90th-percentile FLP decreases substantially from 21.44% at $n=10$ to 11.44% at $n=1{,}000$, showing that larger calibration sets reduce the magnitude of single-run exceedances. Therefore, with a moderate calibration set ($n=1000$), a user should expect the realized FLP to stay close to $\\alpha$, with occasional small exceedances. We will add these results and clarify this practical interpretation of FLR control in the final version.\n\n**2. Robustness to distribution shift [W1, Q2]**\n\nWe emphasize that in our target transductive setting, the calibration set is randomly sampled from the same unlabeled pool as the test set, so the i.i.d. assumption holds by construction. When distribution shift occurs, our theoretical guarantee does not hold, and the empirical FLR can exceed the target level. However, our experiments in Appendix H.1 show that these exceedances are modest and do not increase substantially with the shift severity. Specifically, the maximum FLR is $5.94\\%$ at $\\alpha=0.05$ and $11.77\\%$ at $\\alpha=0.1$, exceeding the respective targets by only $0.94\\%$ and $1.77\\%$. These results demonstrate the empirical robustness of our method to distribution shifts, in the sense that the FLR violations are small even under severe shifts.\n\n**3. Scope of the optimality claims [W2, Q3]**\n\nOur result can be strengthened when the oracle score is available: equipped with $S^\\star(X_{n+j})=P(H_j^0\\text{ is true}\\mid X_{n+j})$, Conformal Labeling is asymptotically power-optimal among all selective labeling methods. In practice the oracle score is unavailable and one can only use an imperfect score such as 1−MSP. In this practical regime, Theorem 3.3 shows that Conformal Labeling attains the optimal power among all thresholding rules based on any fixed score. Non-thresholding rules, which may select examples from multiple disjoint score ranges, could in principle achieve higher power, but how to construct such rules remains unclear. We will add the global optimality result as a formal corollary and clarify the scope of each optimality result in the final version.\n\nThe mFLR-to-FLR bridge used in the oracle-score proof is a commonly adopted technique in multiple testing [1]: the two criteria are asymptotically equivalent for thresholding rules, so the oracle score derived under mFLR is also power-optimal under FLR. We will make this connection more explicit and add relevant citations in the final version.\n\n**4. Choosing uncertainty scores with guarantees [W2, Q4]**\n\nYes, a separate validation set is needed to choose uncertainty scores without invalidating the FLR guarantee. Users can select the score that best approximates the oracle score $S^\\star(X)=\\Pr(H^0\\mid X)$ on a separate labeled validation set and then fix it before applying Conformal Labeling.\n\n**5. Evaluation for large-scale auto-labeling [W2]**\n\nWe conducted a new experiment on the 5,000-example MATH dataset using Qwen3-4B-Instruct-2507. The model has an accuracy of 93.70%, and we use only $n=300$ calibration examples. We report results at $\\alpha\\in\\{0.03,0.05\\}$.\n\n|$\\alpha$|Realized FLR (%)|Power (%)|Selection Ratio (%)|\n|:-:|:-:|:-:|:-:|\n|0.03|2.86|63.66|61.89|\n|0.05|4.84|93.22|92.06|\n\nOn this larger-scale dataset, Conformal Labeling achieves strong performance using only 300 calibration examples. It controls the realized FLR below both target levels while achieving 63.66% power and a 61.89% selection ratio at $\\alpha=0.03$. These results demonstrate the effectiveness of our method in large-scale applications.\n\n**6. The $n_0=0$ edge case [Q5]**\n\nThe $n_0=0$ case is benign for accurate models and does not require a modified procedure. In Appendix H.9, we experiment on HumanEval+ with DeepSeek-R1-Distill-Qwen-32B and observe that our method still attains high power even when $n_0=0$, achieving 100% power at $n=100$.\n\n[1] Sun and Cai. Oracle and adaptive compound decision rules for false discovery rate control. JASA, 2007."+ },+ "createdAt": "2026-07-28T15:10:17.130Z",+ "modifiedAt": "2026-11-19T17:11:24.122Z",+ "url": "https://openreview.net/forum?id=EEhIsOCdWt¬eId=9HGuhh2njN",+ "license": "CC-BY-4.0"+}
reviews/openreview/eehisocdwt/notes/fkbldexbbs.json added
+++ b/reviews/openreview/eehisocdwt/notes/fkbldexbbs.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "fkbLDEXBBS",+ "replyTo": "pqbP6P252P",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer wLuh",+ "content": {+ "comment": "The authors provide a strong rebuttal that addresses the main concerns regarding novelty positioning, single-run FLP risk, calibration size selection, and practical annotation cost. The additional experiments and clarifications significantly improve the understanding of the relationship with conformal selection methods and demonstrate the practical effectiveness of the proposed framework. Although some limitations remain regarding broader theoretical distinctions and calibration under extreme settings, the responses substantially alleviate my concerns, and I will increase my score."+ },+ "createdAt": "2026-08-03T11:33:49.598Z",+ "modifiedAt": "2026-11-19T17:11:24.007Z",+ "url": "https://openreview.net/forum?id=EEhIsOCdWt¬eId=fkbLDEXBBS",+ "license": "CC-BY-4.0"+}
reviews/openreview/eehisocdwt/notes/fuepj02xfz.json added
+++ b/reviews/openreview/eehisocdwt/notes/fuepj02xfz.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "FuEpJ02xfz",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Area Chair 14Yp",+ "content": {+ "comment": "Dear Authors and Reviewers,\n\nThank you for supporting NeurIPS 2026!\n\nWe are now entering the final two days of the discussion phase. Please make the most of this time to exchange your views. I encourage each Reviewer, if you have not already done so, to read the other reviews, the initial meta-review, and the Authors' responses. Please respond to the Authors and actively participate in the discussion to help clarify any remaining issues.\n\nThank you,\n\nNeurIPS 2026 Area Chair"+ },+ "createdAt": "2026-08-02T23:45:12.279Z",+ "modifiedAt": "2026-11-19T17:11:24.241Z",+ "url": "https://openreview.net/forum?id=EEhIsOCdWt¬eId=FuEpJ02xfz",+ "license": "CC-BY-4.0"+}
reviews/openreview/eehisocdwt/notes/i8sftn3gvx.json added
+++ b/reviews/openreview/eehisocdwt/notes/i8sftn3gvx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "I8SfTN3gVx",+ "replyTo": "WsttkLtBgD",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the insightful comments. Please find our response below:\n\n**1. Relationship to Colander [W1, Q1]**\n\nThank you for bringing this related work to our attention. We first provide a comparison with Colander [1] and then discuss the different scopes of these two methods.\n\n> Comparison with Colander\n\nWe compare Conformal Labeling and Colander in two scenarios: (1) the selective auto-labeling setting considered in our work, and (2) the iterative threshold-based auto-labeling (TBAL) protocol adopted by Colander.\n\nFor the first scenario, we run both methods on MATH-500 with Qwen3-4B-Instruct-2507, using the same calibration and test splits and a target FLR of $\\alpha=0.05$. The results in the table below show that Conformal Labeling achieves substantially higher power than Colander while controlling the FLR below the target level.\n\n| Method | FLR (\\%) | Power (\\%) |\n|---|---:|---:|\n| Colander | 2.18 | 38.47 |\n| Conformal Labeling | 4.89 | 94.82 |\n\nWe also conduct an experiment following Colander's iterative TBAL setup. We use MNIST with a LeNet classifier, 200 initial labeled samples, 20 newly queried labels per round, $N_t=500$, $N_v=500$, and $\\epsilon_a=\\alpha=0.05$. We replace only Colander's threshold-selection procedure with Conformal Labeling. The results are summarized in the table below.\n\n| Method | Auto-labeling Error (\\%) | Coverage (\\%) |\n|---|---:|---:|\n| Colander | 3.45 | 83.74 |\n| Conformal Labeling | 5.61 | 94.33 |\n\nThese results show that Colander controls the auto-labeling error, whereas Conformal Labeling slightly exceeds the target level. This discrepancy may arise from two reasons: first, the i.i.d. assumption may be violated during the iterative process; second, controlling the FLR at level $\\alpha$ for two round-wise selected sets does not theoretically imply that their union has expected FLR at most $\\alpha$.\n\n> Discussion of Colander\n\nThese comparisons clarify the different scopes of the two methods, and we view Colander as complementary to Conformal Labeling rather than a competing method. Colander learns the confidence function and the threshold jointly with the classifier for the iterative TBAL protocol, where the model is retrained every round and the labeled pool shifts; its std-based safety margin is precisely what enables it to control the error empirically even under these updates. Our setting instead fixes the labeling model and selects in a single step, and on this premise the conformal $p$-value together with our selection algorithm yields a tight FLR control, which translates into substantially higher power at the same target level (94.82% vs. 38.47%). Importantly, Conformal Labeling needs no retraining and no model internals, so it applies directly to modern LLM-based labeling pipelines, where Colander's confidence-learning step is unavailable. We will cite Colander, include both comparisons, and clarify these different scopes in the final version.\n\n\n[1] Vishwakarma et al. Pearls from Pebbles: Improved Confidence Functions for Auto-labeling. NeurIPS, 2024."+ },+ "createdAt": "2026-07-28T15:10:07.825Z",+ "modifiedAt": "2026-11-19T17:11:24.273Z",+ "url": "https://openreview.net/forum?id=EEhIsOCdWt¬eId=I8SfTN3gVx",+ "license": "CC-BY-4.0"+}
reviews/openreview/eehisocdwt/notes/jjxggmshtd.json added
+++ b/reviews/openreview/eehisocdwt/notes/jjxggmshtd.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "jJXgGMSHtD",+ "replyTo": "I8SfTN3gVx",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer KNwD",+ "content": {+ "comment": "Thank you for these experiments. I will raise the originality score."+ },+ "createdAt": "2026-08-02T04:22:11.298Z",+ "modifiedAt": "2026-11-19T17:11:24.046Z",+ "url": "https://openreview.net/forum?id=EEhIsOCdWt¬eId=jJXgGMSHtD",+ "license": "CC-BY-4.0"+}
reviews/openreview/eehisocdwt/notes/pqbp6p252p.json added
+++ b/reviews/openreview/eehisocdwt/notes/pqbp6p252p.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "pqbP6P252P",+ "replyTo": "uFSJ4qR9ao",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "**4. Annotation cost accounting for generation tasks [W3]**\n\nWe would like to clarify that the relatively large calibration-to-test ratio in some generation experiments is an artifact of the small public benchmarks, rather than a limitation of our method. For example, MATH-500 contains only 500 problems. In practical large-scale applications, where the test set is substantially larger than the calibration set, annotation cost savings are primarily determined by the selection ratio on the test set.\n\nFurthermore, we conduct a new large-scale experiment on the MATH dataset (5,000 examples) with Qwen3-4B-Instruct-2507 and a calibration size of $n=300$. We report the overall cost saving, $\\frac{\\text{number of auto-labeled instances}}{n+m}$, which accounts for both the annotation cost spent and the labels saved. The accuracy of the LLM is 93.70%.\n\n|$\\alpha$ | Realized FLR (%) | Power (%) | Overall cost saving (%) |\n|:-:|:-:|:-:|:-:|\n| 0.03 | 2.86 | 63.66 | 58.18 |\n| 0.05 | 4.84 | 93.22 | 86.54 |\n\nThe results show that in the realistic large-scale setting, our method achieves high overall cost saving — reducing human annotation by 58.18% at $\\alpha=0.03$ and 86.54% at $\\alpha=0.05$ — while controlling the realized FLR below both target levels. These results show the practical annotation savings of Conformal Labeling on a larger dataset.\n\n[1] Jin, Ying, and Emmanuel J. Candès. “Selection by Prediction with Conformal p-Values.” Journal of Machine Learning Research, vol. 24, no. 244, 2023, pp. 1–41.\n\n[2] Gui, Yu, Ying Jin, and Zhimei Ren. “Conformal Alignment: Knowing When to Trust Foundation Models with Guarantees.” Advances in Neural Information Processing Systems, vol. 37, 2024, pp. 73884–73919.\n\n[3] Benjamini, Yoav, and Yosef Hochberg. “Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing.” Journal of the Royal Statistical Society: Series B (Methodological), vol. 57, no. 1, 1995, pp. 289–300.\n\n[4] Storey, John D. “A Direct Approach to False Discovery Rates.” Journal of the Royal Statistical Society: Series B (Statistical Methodology), vol. 64, no. 3, 2002, pp. 479–498."+ },+ "createdAt": "2026-07-28T15:13:40.087Z",+ "modifiedAt": "2026-11-19T17:11:24.323Z",+ "url": "https://openreview.net/forum?id=EEhIsOCdWt¬eId=pqbP6P252P",+ "license": "CC-BY-4.0"+}
reviews/openreview/eehisocdwt/notes/psgt11xz2u.json added
+++ b/reviews/openreview/eehisocdwt/notes/psgt11xz2u.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "PSgt11xZ2U",+ "replyTo": "fkbLDEXBBS",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for taking the time to read our rebuttal and for your positive feedback! We are excited to hear that our responses have resolved your main concerns about this work. We noticed your kind note mentioning that you will raise your score. However, it appears the OpenReview system hasn't reflected this update yet. Could you please kindly check if the score change was successfully saved?"+ },+ "createdAt": "2026-08-03T15:58:42.707Z",+ "modifiedAt": "2026-11-19T17:11:23.843Z",+ "url": "https://openreview.net/forum?id=EEhIsOCdWt¬eId=PSgt11xZ2U",+ "license": "CC-BY-4.0"+}
reviews/openreview/eehisocdwt/notes/qhmbmolcmf.json modified
+++ b/reviews/openreview/eehisocdwt/notes/qhmbmolcmf.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 14Yp","content": {- "metareview": "This paper proposes Conformal Labeling, a principled framework for selective auto-labeling that casts the selection of reliable auto-generated labels as a multiple testing problem. Reviewers agree that the paper addresses an important and practical problem, and highlight the method’s clean formulation, strong statistical grounding, and appealing finite-sample guarantees. At the same time, several key issues are raised that would benefit from clarification in the rebuttal. In particular, reviewers note that the novelty relative to closely related conformal selection and threshold-based auto-labeling methods should be more clearly articulated and empirically validated. Additionally, the scope and interpretation of the reliability guarantee require more careful discussion, especially regarding its marginal nature, behavior under distribution shift, and implications for single-run deployments. Reviewers also request clearer guidance on practical aspects such as uncertainty score selection, calibration size, and more realistic large-scale evaluation settings."+ "metareview": "This paper proposes Conformal Labeling, a principled framework for selective auto-labeling that casts the selection of reliable auto-generated labels as a multiple testing problem. Reviewers agree that the paper addresses an important and practical problem, and highlight the method’s clean formulation, strong statistical grounding, and appealing finite-sample guarantees. At the same time, several key issues are raised that would benefit from clarification in the rebuttal. In particular, reviewers note that the novelty relative to closely related conformal selection and threshold-based auto-labeling methods should be more clearly articulated and empirically validated. Additionally, the scope and interpretation of the reliability guarantee require more careful discussion, especially regarding its marginal nature, behavior under distribution shift, and implications for single-run deployments. Reviewers also request clearer guidance on practical aspects such as uncertainty score selection, calibration size, and more realistic large-scale evaluation settings.",+ "final_justification": "After the rebuttal phase, the authors have adequately addressed the reviewers’ major concerns. All reviewers maintained their positive assessments of the paper and reached a consensus in recommending it for publication. Considering the overall quality and contributions of the paper, as well as the exchanges throughout the rebuttal process, my final recommendation is acceptance."},"createdAt": "2026-07-21T15:05:42.763Z",- "modifiedAt": "2026-11-18T15:22:15.439Z",+ "modifiedAt": "2026-11-19T05:01:22.043Z","url": "https://openreview.net/forum?id=EEhIsOCdWt¬eId=qHMbmOlcmF","license": "CC-BY-4.0"}
reviews/openreview/eehisocdwt/notes/ufsj4qr9ao.json added
+++ b/reviews/openreview/eehisocdwt/notes/ufsj4qr9ao.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "uFSJ4qR9ao",+ "replyTo": "z3SCe7n6Kb",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely appreciate the reviewer's constructive feedback. Please find our response below:\n\n**1. Relationship to conformal alignment [W1, Q1]**\n\nWe clarify that Conformal Alignment (CA)/Selection (CS) [1, 2] cannot be directly applied to the labeling problem. The BH baseline in Table 3 is applying standard BH procedure [3] to **our $p$-values**, instead of CA's $p$-values. CS is a screening framework that combines conformal $p$-values with BH procedures to select candidates whose **unobserved outcomes exceed a user-specified threshold**. CA adapts this framework to alignment tasks by training an alignment score predictor as the nonconformity score function. *As discussed in related work (Section 5), we position our work as motivating and tailoring the framework of conformal selection for selective labeling and support its application to open-ended generation tasks.* In particular, our work differs from CA/CS in threefolds:\n\n\n- **Formulation and assumptions:** CS/CA is designed to select examples whose unobserved outcomes (a continuous variable, e.g., the alignment score in CA) exceed user-specified values, while our work aims to select examples with correct auto-generated label, which is a discrete variable. In assumptions, they assume the nonconformity score $V(X, Y)$ is monotone with $Y$ and CA requires a training set to fit an alignment predictor. In contrast, our method uses uncertainty score $S(X)$ without involving $Y$ and does not require a training set.\n\n- **$p$-value construction:** CS/CA constructs $p$-values using the full calibration set and establishes $P(\\hat p_j\\leq t,\\ H_0^j\\text{ is true})\\leq t.$ In contrast, we construct $p$-values using the mislabeled calibration samples and provide a stronger guarantee: $P(\\hat p_j\\leq t\\mid H_0^j\\text{ is true})\\leq t.$ Thus, the two constructions provide distinct validity guarantees tailored to different testing problems.\n\n- **Selection procedure:** CS/CA only supports using standard BH without correction. Applying BH with any correction factor (e.g., Storey correction [4]) to CS's $p$-values is not theoretically justified. In contrast, our method can employ a novel correction factor to the BH procedure due to the strong null validity of the proposed $p$-value. As a result, the novel design substantially improves the power over standard BH as shown in Table 3.\n\nTherefore, our contribution beyond prior conformal selection works includes a new selective-labeling formulation, a different $p$-value construction, and a high-power correction factor. In the Introduction of the current version, we focus on justifying the motivation of providing FLR control in selective auto-labeling. As the reviewer suggested, we will explicitly clarify its relationship with CS in the final version.\n\n**2. Single-run risk under FLR control [W2, Q2]**\n\nThank you for the suggestion. To quantify single-run risk for highly accurate model, we conduct new experiments on MATH-L5 with Qwen3-4B-Thinking-2507 at $\\alpha=0.03$. We report $P(\\mathrm{FLP}>\\alpha)$ and the 90th percentile of FLP over 1,000 repetitions with different calibration sizes.\n\n|n|$P(\\mathrm{FLP}>\\alpha)$ (%)|90th pct. FLP (%)|Power (%)|\n|-|-:|-:|-:|\n|10|8.6|0.0|0.40|\n|50|36.71|4.62|50.58|\n|100|41.89|4.27|66.99|\n\nFor a highly accurate model, when $n$ is very small ($n=10$), the power is low and $P(\\mathrm{FLP}>\\alpha)$ is correspondingly low. As $n$ increases, the realized FLP becomes increasingly concentrated around $\\alpha$. $P(\\mathrm{FLP}>\\alpha)$ approaches 50% and the 90th-percentile FLP decreases towards $\\alpha$. Therefore, with a moderate-sized calibration set, users can expect the realized FLP to remain close to the target in magnitude, although it may exceed $\\alpha$. We will add these results and clarify this practical interpretation of FLR control in the final version.\n\n**[Q3] Practical guidance on choosing the calibration size.**\n\nThank you for the suggestion. For a moderately accurate model, our ablation in Appendix H.7 shows that $n_0 = 50$ already yields informative $p$-values and high power for Qwen3-32B on MedMCQA, corresponding to $n \\approx 150$ there. We therefore recommend $n \\approx 50/\\pi_0$, where $\\pi_0$ denotes the proportion of incorrect predictions.\n\nFor a highly accurate model, a much smaller $n$ suffices. Consider the extreme case where the model achieves 100\\% accuracy. The BH threshold in Eq. (4) at $j = m$ then becomes $\\alpha(n+1)/m \\cdot m = \\alpha(n+1)$, so as soon as $n \\gtrsim 1/\\alpha$ every $p$-value passes the test and all labels are accepted. This matches Appendix H.9, where at $\\alpha = 0.01$ power jumps from 41.78% at $n = 90$ to 100.00% at $n = 100$. Thus, we believe $n=\\frac{1}{\\alpha}$ suffices for highly accurate models."+ },+ "createdAt": "2026-07-28T15:13:25.733Z",+ "modifiedAt": "2026-11-19T17:11:24.130Z",+ "url": "https://openreview.net/forum?id=EEhIsOCdWt¬eId=uFSJ4qR9ao",+ "license": "CC-BY-4.0"+}
reviews/openreview/eehisocdwt/notes/vn3sxl1stk.json added
+++ b/reviews/openreview/eehisocdwt/notes/vn3sxl1stk.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "vn3SXL1Stk",+ "replyTo": "jJXgGMSHtD",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for your encouraging feedback and for raising the originality score. We sincerely appreciate the time and effort you dedicated to reviewing our work!"+ },+ "createdAt": "2026-08-02T23:51:54.643Z",+ "modifiedAt": "2026-11-19T17:11:24.018Z",+ "url": "https://openreview.net/forum?id=EEhIsOCdWt¬eId=vn3SXL1Stk",+ "license": "CC-BY-4.0"+}