MedFlowSeg: Flow Matching for Medical Image Segmentation with Frequency-Aware Attention
Import NeurIPS 2026 submission bf3XH3GbLU: 8 notes
@openreview[bot] · 2026-11-22 17:58 UTC · 6922edee7f6b ·
reviews/openreview/bf3xh3gblu/forms.json added
+++ b/reviews/openreview/bf3xh3gblu/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/bf3xh3gblu/notes/4dpki2kutc.json added
+++ b/reviews/openreview/bf3xh3gblu/notes/4dpki2kutc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "4DPKI2kUtC",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair msh4",+ "content": {+ "metareview": "The paper proposes MedFlowSeg, a conditional flow-matching framework for generative medical image segmentation with dual spatial- and frequency-aware conditioning. The reviewers seem to view the problem as important, the method as reasonably original, and the evaluation across five modalities as broad, with good gains in efficiency relative to diffusion-based approaches [PgFc, jsmF, nzj5]. The most important unresolved issue is that the conditioning network is itself trained with a supervised Dice/CE segmentation loss while also receiving gradients through the flow-matching model, making it unclear how much of the final performance is due to flow matching rather than the conditioning branch alone [jsmF]. The rebuttal should prioritize clarifying the effects of such supervision and ideally what remains when the auxiliary Dice/CE supervision is removed or controlled. Other concerns include the lack of repeated-run statistics despite small margins over baselines, unclear fairness of preprocessing and multi-sample STAPLE comparisons, insufficient isolation of the frequency decomposition, and limited evidence for true 3D generalization and uncertainty advantages [PgFc, jsmF, nzj5]."+ },+ "createdAt": "2026-07-19T08:08:57.672Z",+ "modifiedAt": "2026-11-18T15:22:19.102Z",+ "url": "https://openreview.net/forum?id=bf3XH3GbLU¬eId=4DPKI2kUtC",+ "license": "CC-BY-4.0"+}
reviews/openreview/bf3xh3gblu/notes/8z5gkrms5o.json added
+++ b/reviews/openreview/bf3xh3gblu/notes/8z5gkrms5o.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "8z5GKRmS5O",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer jsmF",+ "content": {+ "summary": "The paper proposes a framework that leverages conditional flow matching for image segmentation. \nThe contributions of the paper are: \n- the formulation of segmentation as a conditional flow matching problem\n- the design of a conditioning network to ground the flow matching process to the input image \n- comparisons with other methods on 5 datasets comprising several different medical imaging modalities (MRI, Histopathology, fundus photographs, ultrasound), demonstrating competitive performance of the proposed approach.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths \n1) Generative segmentation is useful as long as it is effectively grounded on an input image. The paper identifies this and presents an improved conditioning method that interacts with the velocity prediction network at both early and intermediate layers.\n\n2) Thorough empirical evaluation of the method for medical image segmentation comprising several different modalities and domains (MRI, fundus photographs, histology, and ultrasound). A broad choice of baselines is used (generative and deterministic).\n\n3) Method's efficiency: the reported GFLOPs are substantially lower than several diffusion and flow baselines.\n\nWeaknesses\n\n1) The paper contains confounded insights regarding the value of using the flow matching framework for improving the segmentation performance. The key confounder for this is the fact that the conditioning network is trained with a direct supervised Dice/CE segmentation objective and also receives gradients through the flow-matching network.. Towards clarifying this what the paper is missing is:\n- Evaluating the performance of the conditioning network (trained with the dice+CE loss). This would help understand how much the flow-matching network improves performance relative to its conditioning branch.\n- Removing the dice loss completely to isolate the flow-matching network's performance.\n \n2) The paper claims better conditioning enables efficient sampling but does not test how changes to the conditioning method (those listed in Table 3.) affect the number of samples needed to reach a certain performance.\n\n3) DB-SA is compared only against standard spatial attention. That is not enough to show that the dual-frequency decomposition is necessary. This introduces method complexity without adequate justification or insights. Is the gain from frequency decomposition? What is the relative importance of low vs high frequency structure?",+ "quality": 3,+ "clarity": 3,+ "significance": 2,+ "originality": 2,+ "questions": "Minor:\n1) In line 114 it is stated \" Notably, instead of the conventional mean squared error, our pipeline specifically minimizes the expected L1 error. This design choice is employed to robustly penalize velocity estimation errors and better preserve sharp structural boundaries in the segmentation\". Is this experimentally validated? \n\n2) What type of conditioning used for the experiment reported first line of Table 3 ? Or is this a the results without flow matching, simply training the conditioning network for segmentation using the dice loss?\n\nMajor:\n3) Please see suggestions for additional experiments which in Weaknesses 1, 2, 3. These experiments would help better understand the value of using the flow-matching framework for segmentation and better characterize the importance of design choices made in the conditioning branch.",+ "limitations": "Yes",+ "rating": 3,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No concerns",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "As per my comment to the rebuttal, I find the methodological contribution clear and the experimental validation adequate. Conclusively, I raise my score to \"Accept\"."+ },+ "createdAt": "2026-06-26T14:46:37.326Z",+ "modifiedAt": "2026-11-18T13:40:41.089Z",+ "url": "https://openreview.net/forum?id=bf3XH3GbLU¬eId=8z5GKRmS5O",+ "license": "CC-BY-4.0"+}
reviews/openreview/bf3xh3gblu/notes/cyrkthjpll.json added
+++ b/reviews/openreview/bf3xh3gblu/notes/cyrkthjpll.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "CYRKthjPLl",+ "replyTo": "8z5GKRmS5O",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for your valuable feedback. We will address the concerns regarding the identified weaknesses and respond to your questions accordingly.\n\n## Additional Results\n\n| Setting | ACDC Dice ↑ | ACDC IoU ↑ | BraTS-2021 Dice ↑ | BraTS-2021 IoU ↑ |\n|:---|:---:|:---:|:---:|:---:|\n| Conditioning branch | 90.61 | 82.43 | 88.57 | 80.65 |\n| MedFlowSeg w/o Auxiliary Loss | 91.86 | 84.79 | 89.52 | 83.29 |\n| Full MedFlowSeg | **93.57** | **87.73** | **91.19** | **84.52** |\n\n## Weaknesses\n\n> [Weaknesses 1] The paper contains confounded insights regarding the value of using the flow matching framework for improving the segmentation performance. The key confounder for this is the fact that the conditioning network is trained with a direct supervised Dice/CE segmentation objective and also receives gradients through the flow-matching network.. Towards clarifying this what the paper is missing is:\n> - Evaluating the performance of the conditioning network (trained with the dice+CE loss). This would help understand how much the flow-matching network improves performance relative to its conditioning branch.\n> - Removing the dice loss completely to isolate the flow-matching network's performance.\n\nIn the additional results, we conduct further ablation studies to disentangle the roles of the conditioning network, the auxiliary objective, and the flow-matching component. Since the conditioning network is implemented as a simple U-Net, its standalone performance is already shown to be relatively limited in the original manuscript. Therefore, the **Conditioning branch** setting reports the segmentation produced directly by the auxiliary segmentation head. Its lower performance further indicates that the improvement of the full model is primarily attributable to the flow-matching network rather than the supervised conditioning branch alone.\n\nMedFlowSeg without the auxiliary Dice/CE loss also performs worse than the full model. We attribute this to the insufficient direct optimization signal for the conditioning pathway when gradients are provided only through the flow-matching objective, making the optimization more likely to converge to a suboptimal solution. In our experiments, adding the auxiliary loss noticeably reduced the number of training epochs required and led to faster convergence. These observations suggest that the auxiliary objective provides explicit structural guidance and facilitates optimization.\n\n> [Weaknesses 2] The paper claims better conditioning enables efficient sampling but does not test how changes to the conditioning method (those listed in Table 3.) affect the number of samples needed to reach a certain performance.\n\nWe thank the reviewer for pointing this out. We agree that the current discussion does not sufficiently isolate the effect of conditioning on sampling efficiency. Figure 9 in the Appendix already compares MedFlowSeg with other generative segmentation baselines across different numbers of sampling steps. Our results further indicate that the proposed conditioning reaches near-saturated performance with fewer steps than the alternative conditioning variants. We are therefore considering extending Figure 9 to include all conditioning variants from Table 3 across different numbers of sampling steps.\n\n\n> [Weaknesses 3] DB-SA is compared only against standard spatial attention. That is not enough to show that the dual-frequency decomposition is necessary. This introduces method complexity without adequate justification or insights. Is the gain from frequency decomposition? What is the relative importance of low vs high frequency structure?\n\nTable 3 shows that replacing standard spatial attention with DB-SA consistently improves segmentation performance, indicating that the gain is not merely due to adding attention, but is associated with the frequency-decomposed structural guidance.\n\nThe two branches are designed to be complementary and to better represent the uncertainty inherent in the conditional features. The low-frequency branch captures stable coarse anatomical structure and region-level context, while the high-frequency branch preserves uncertain local variations, boundaries, and fine details. Their fusion enables DB-SA to provide structural guidance that is both globally consistent and sensitive to ambiguous boundary information.\n\nWe agree that the current results do not fully quantify their relative importance. We are excited to include additional low-frequency-only and high-frequency-only ablations in the camera-ready version to better clarify the individual and complementary contributions of the two branches.\n\n## Questions\n\n> [Question 1] In line 114 it is stated \" Notably, instead of the conventional mean squared error, our pipeline specifically minimizes the expected L1 error. This design choice is employed to robustly penalize velocity estimation errors and better preserve sharp structural boundaries in the segmentation\". Is this experimentally validated?\n\nOur choice of the L1 velocity objective was initially motivated by the empirical findings of *Palette: Image-to-Image Diffusion Models*. Palette reports that L1 and L2 objectives achieve similar overall sample quality, but exhibit different generation behavior: L2 produces greater sample diversity, whereas L1 yields more conservative outputs with stronger adherence to the conditional input.\n\nFor medical image segmentation, fidelity to the input anatomy and ground-truth structure is more important than maximizing output diversity. Based on this observation, we independently trained MedFlowSeg with L1 and L2 velocity objectives under the same configuration. We observed that L1 produced more structurally consistent predictions and better preserved fine anatomical boundaries. \n\n> [Question 2] What type of conditioning used for the experiment reported first line of Table 3 ? Or is this a the results without flow matching, simply training the conditioning network for segmentation using the dice loss?\n\nThe conditioning in the first row of Table 3 is implemented through direct concatenation. We will clarify this setting explicitly in the revised manuscript."+ },+ "createdAt": "2026-07-28T11:31:01.942Z",+ "modifiedAt": "2026-11-18T17:17:42.820Z",+ "url": "https://openreview.net/forum?id=bf3XH3GbLU¬eId=CYRKthjPLl",+ "license": "CC-BY-4.0"+}
reviews/openreview/bf3xh3gblu/notes/d1h3mcxvod.json added
+++ b/reviews/openreview/bf3xh3gblu/notes/d1h3mcxvod.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "d1h3MCxVod",+ "replyTo": "msH4F418PI",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for your thoughtful comments. We will thoughtfully address all of your suggestions and concerns in our revised submission.\n\n## Additional Results\n\n### Results Across Test Subjects\n| Methods | ACDC Dice ↑ | ACDC IoU ↑ | BraTS-2021 Dice ↑ | BraTS-2021 IoU ↑ |\n|:---|:---:|:---:|:---:|:---:|\n| MedFlowSeg w/o STAPLE | 93.14 ± 6.13 | 87.49 ± 10.59 | 90.84 ± 8.12 | 84.28 ± 13.73 |\n| MedFlowSeg w/ STAPLE | **93.57 ± 4.49** | **87.73 ± 8.05** | **91.19 ± 6.83** | **84.52 ± 10.18** |\n\n### Results Across Random Seeds\n| Methods | ACDC Dice ↑ | ACDC IoU ↑ | BraTS-2021 Dice ↑ | BraTS-2021 IoU ↑ |\n|:---|:---:|:---:|:---:|:---:|\n| MedFlowSeg | **93.56 ± 0.05** | **87.71 ± 0.07** | **91.19 ± 0.04** | **84.51 ± 0.06** |\n\n## Questions\n> [Question 1] Were all baselines retrained with the same preprocessing, resolution, augmentation, and splits?\n\nYes. All baselines were retrained using the same preprocessing pipeline, input resolution, data augmentation strategy, and train/validation/test splits as our method to ensure a fair comparison.\n\n> [Question 2] Can the authors report single sample results, in addition to the 10-sample STAPLE-fused results?\n\nIn the additional results, we compare MedFlowSeg using a single prediction without STAPLE with the 10-sample STAPLE-fused setting on ACDC and BraTS-2021. STAPLE yields modest improvements in average Dice and IoU, while its main benefit is the consistent reduction in standard deviation. This indicates that STAPLE primarily improves the stability and robustness of the segmentation results rather than substantially increasing the mean performance.\n\n> [Question 3] Can the authors provide error bars or results across multiple seeds?\n\nIn the additional results, we report the mean and standard deviation over five independent runs with different random seeds. MedFlowSeg achieves stable performance on both ACDC and BraTS-2021, with consistently small standard deviations for Dice and IoU. These results demonstrate that the performance is robust to random initialization and training stochasticity.\n\n> [Question 4] How does accuracy change with fewer ODE steps and fewer ensemble samples?\n\nAs reported in the Appendix of the submitted paper, we have evaluated MedFlowSeg using fewer ODE steps. The model already achieves competitive Dice performance with a single ODE step and approaches its best performance within a small number of steps, indicating rapid performance saturation as the sampling budget increases.\n\nRegarding the number of ensemble samples, our additional results show that STAPLE has only a modest effect on the mean Dice and IoU scores. Its main benefit is the consistent reduction in standard deviation, suggesting that using more ensemble samples primarily improves prediction stability and robustness rather than substantially increasing average accuracy.\n\n> [Question 5] How well does the method extend to true 3D segmentation?\n\nWe thank the reviewer for raising this important point. We agree that the current implementation operates on 2D slices rather than directly modeling complete 3D volumes. However, for 3D datasets, all evaluation metrics are computed at the patient level after aggregating the slice-wise predictions into complete volumes. Thus, the reported results reflect volumetric segmentation quality at the patient level, although the model itself does not explicitly exploit inter-slice information.\n\nA fully 3D extension is an important direction for future work. In particular, we will focus on enabling information sharing across adjacent slices to improve volumetric consistency, while avoiding the substantial computational and memory overhead associated with conventional fully 3D architectures."+ },+ "createdAt": "2026-07-28T11:30:51.493Z",+ "modifiedAt": "2026-11-18T17:17:42.477Z",+ "url": "https://openreview.net/forum?id=bf3XH3GbLU¬eId=d1h3MCxVod",+ "license": "CC-BY-4.0"+}
reviews/openreview/bf3xh3gblu/notes/msh4f418pi.json added
+++ b/reviews/openreview/bf3xh3gblu/notes/msh4f418pi.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "msH4F418PI",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer PgFc",+ "content": {+ "summary": "This work addresses the central challenge of making generative medical image segmentation more efficient and better guided by the input image. The paper proposes MedFlowSeg, a flow matching segmentation framework with two conditioning modules: DB-SA for structural guidance and FA-Attention for aligning noisy flow states with cleaner semantic features. The method is tested across several medical imaging modalities and reports strong results against deterministic, diffusion based, and flow based baselines.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "The paper tackles a relevant problem. Diffusion based segmentation can be slow, and flow matching is a sensible alternative. The proposed conditioning strategy is well motivated, and the results across ACDC, BraTS, REFUGE2, GlaS, and CAMUS are convincing. The ablation study also supports the usefulness of the two proposed modules.\nHowever, the claims are somewhat stronger than the evidence fully supports. The paper presents the method as a general medical image segmentation framework, but the experiments are still based on 2D resized benchmark images. This limits the strength of the generalization claim, especially for 3D clinical imaging. The comparison protocol also needs more detail, particularly whether baselines were retrained under the same preprocessing and whether the reported gains partly come from using 10 samples with STAPLE fusion.\nOverall, the method is strong, but the paper would benefit from clearer single sample results, more statistical analysis, and a more careful discussion of deployment limits.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "1. Were all baselines retrained with the same preprocessing, resolution, augmentation, and splits?\n2. Can the authors report single sample results, in addition to the 10-sample STAPLE-fused results?\n3. Can the authors provide error bars or results across multiple seeds?\n4. How does accuracy change with fewer ODE steps and fewer ensemble samples?\n5. How well does the method extend to true 3D segmentation?",+ "limitations": "The authors acknowledge useful limitations, including model size, 2D slice based processing, and possible domain shift issues. The discussion would be stronger if it also addressed clinical deployment risks and scanner/site variability.",+ "rating": 5,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "Figures 1-3 would benefit from being enlarged to span the full width of the printable area, as the current scaling makes several details difficult to read.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "As per my comment to the rebuttal:\n\nI am satisfied with the clarifications, which should be included in the final version of the manuscript, and the paper should also make clear that the method is still slice-based and does not directly model 3D. I maintain my score of Accept."+ },+ "createdAt": "2026-07-16T11:29:31.157Z",+ "modifiedAt": "2026-11-18T13:40:39.701Z",+ "url": "https://openreview.net/forum?id=bf3XH3GbLU¬eId=msH4F418PI",+ "license": "CC-BY-4.0"+}
reviews/openreview/bf3xh3gblu/notes/mvjq6l0c7y.json added
+++ b/reviews/openreview/bf3xh3gblu/notes/mvjq6l0c7y.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "MVjQ6L0C7y",+ "replyTo": "OVDRQUOjh9",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for your constructive feedback. We will provide detailed responses to your questions.\n\n## Additional Results\n\n| Setting | ACDC Dice ↑ | ACDC IoU ↑ | BraTS-2021 Dice ↑ | BraTS-2021 IoU ↑ |\n|:---|:---:|:---:|:---:|:---:|\n| Conditioning branch | 90.61 | 82.43 | 88.57 | 80.65 |\n| MedFlowSeg w/o Auxiliary Loss | 91.86 | 84.79 | 89.52 | 83.29 |\n| Full MedFlowSeg | **93.57** | **87.73** | **91.19** | **84.52** |\n\n### Results Across Test Subjects\n| Methods | ACDC Dice ↑ | ACDC IoU ↑ | BraTS-2021 Dice ↑ | BraTS-2021 IoU ↑ |\n|:---|:---:|:---:|:---:|:---:|\n| MedFlowSeg w/o STAPLE | 93.14 ± 6.13 | 87.49 ± 10.59 | 90.84 ± 8.12 | 84.28 ± 13.73 |\n| MedFlowSeg w/ STAPLE | **93.57 ± 4.49** | **87.73 ± 8.05** | **91.19 ± 6.83** | **84.52 ± 10.18** |\n\n### Results Across Random Seeds\n| Methods | ACDC Dice ↑ | ACDC IoU ↑ | BraTS-2021 Dice ↑ | BraTS-2021 IoU ↑ |\n|:---|:---:|:---:|:---:|:---:|\n| MedFlowSeg | **93.56 ± 0.05** | **87.71 ± 0.07** | **91.19 ± 0.04** | **84.51 ± 0.06** |\n\n## Questions\n\n> [Question 1] Although the papers argue this statement is true for diffusion models in generative segmentation, they do not show any experiments to back this. I suggest the authors to either back these claims with empirical results for catastrophic failures, or tone down their preface for diffusion models.\n\nWe thank the reviewer for this comment. Table 2 provides empirical evidence that diffusion-based generative segmentation methods can achieve state-of-the-art performance on individual tasks, while their performance is less consistent across different modalities and datasets. This observation motivated our discussion of task-dependent performance and limited cross-modality consistency.\n\nHowever, we agree that these results do not directly demonstrate catastrophic failures. We will therefore tone down the corresponding discussion in the introduction and describe the limitation more precisely as inconsistent or task-dependent performance across segmentation settings, rather than implying that diffusion-based methods generally suffer from catastrophic failures.\n\n> [Question 2] Same comment as above. Without empirical backing, it's unfair to make such assumptions. Can the authors either point me to the experiments, or please add such experiments to back their claims?\n\nAs noted in our response to Question 1, Table 2 provides empirical evidence that existing diffusion-based generative segmentation methods often achieve strong performance on individual benchmarks, while their results are less consistent across different modalities, datasets, and segmentation settings. This observation motivated our discussion of their task-dependent behavior and limited cross-setting generalization.\n\nHowever, we agree that the current experiments do not directly establish that these methods are inherently tailored to specific tasks, nor do they isolate task-specific design as the cause of their limited generalization. We will therefore revise this statement to avoid making an insufficiently supported assumption.\n\n> [Question 3] Although this is mostly true, there's several efforts in context of probabilistic segmentation regime, in particular -- PUNet (https://arxiv.org/abs/1806.05034) and PhiSeg (https://arxiv.org/abs/1906.04045) are the two most successful ones. I suggest the authors investigate and report results of prior methods carefully and share experiments for generative segmentation paradigm prior to diffusion models.\n\nOur intention was to contrast diffusion-based generative segmentation with conventional deterministic methods that produce a single segmentation output, rather than to suggest that all prior segmentation methods lack explicit uncertainty modeling. We will revise the introduction accordingly and qualify the statement by referring specifically to deterministic segmentation approaches. \n\nFollowing the reviewer’s suggestion, where compatible implementations and evaluation settings are available, we will include Probabilistic U-Net and PHiSeg as additional baselines in Tables 1 and 2.\n\n> [Question 4] Reading the equation closely (with lambda and alpha parameter values): 1) Is there a rationale to chose fixed parameter values? 2) The effective value reads to me as Ltotal = Lvel + λLaux -- Ltotal = Lvel + λ (Ldice + αLce) -- Ltotal = Lvel + 0.1 (Ldice + 10 x Lce) -- Ltotal = Lvel + 0.1 Ldice + Lce\n> If it's downweighting dice loss at the end of the day with no particular reward to cross entropy, isn't the net balancing done by penalizing the dice further? I don't see the rationale for doing this. Do the authors have an ablation study to back such a choice?\n\nThe reviewer is correct that, with $\\lambda=0.1$ and $ \\alpha=10$, the objective can be equivalently written as\n\n$L_{\\rm total}=L_{\\rm vel}+0.1L_{\\rm dice}+L_{\\rm ce}$\n\nOur auxiliary loss design was initially inspired by MedSegDiff-V2, which employs the same relative weighting between the Dice and cross-entropy terms, i.e., $L_{\\rm dice}+10L_{\\rm ce}$. In MedSegDiff-V2, however, this auxiliary segmentation loss is applied only when the diffusion timestep $t$ is divisible by 5. In our implementation, we found that applying the auxiliary supervision consistently with a fixed coefficient resulted in more stable performance. We therefore use\n\n$L_{\\rm total}=L_{\\rm vel}+0.1\\left(L_{\\rm dice}+10L_{\\rm ce}\\right)$\n\nThe relatively larger weight assigned to cross-entropy is motivated by the multi-class nature of our segmentation tasks. The velocity-prediction objective primarily supervises the diffusion denoising process and, by itself, does not explicitly impose sufficiently strong class-discriminative constraints. Cross-entropy provides direct voxel-wise supervision over the semantic classes and penalizes incorrect class assignments, which is particularly important for stable multi-class segmentation. The Dice term complements this supervision by encouraging region-level overlap, but its contribution is downweighted to prevent the auxiliary overlap objective from dominating the velocity-prediction objective.\n\nIn the additional results, MedFlowSeg without the auxiliary Dice/CE loss also performs worse than the full model. We attribute this to the insufficient direct optimization signal for the conditioning pathway when gradients are provided only through the flow-matching objective, making the optimization more likely to converge to a suboptimal solution. In our experiments, adding the auxiliary loss noticeably reduced the number of training epochs required and led to faster convergence. These observations suggest that the auxiliary objective provides explicit structural guidance and facilitates optimization.\n\n> [Question 5] The reported results do not seem statistically significant to me. Could you authors report the mean and standard deviation for a 5-fold training run across experiments? If the statistical significance is missing, it's hard to grasp if it's a stochastic run with incremental gains or it indeed performs well consistency!\n\nWe agree that reporting only a single aggregate value does not fully demonstrate whether the observed improvements are consistent or attributable to stochastic variation.\n\nOur current Table 4 partially addresses this issue by reporting the Generalized Energy Distance (GED) and confidence interval (CI), which measure distributional alignment and prediction stability, respectively. These results provide complementary evidence regarding the consistency and uncertainty of the generated segmentations.\n\nIn the additional results, we conducted additional analyses across test subjects and random seeds. The results across test subjects show that STAPLE-based aggregation improves the mean performance while reducing the variability across subjects. Moreover, the results across independent random seeds exhibit very small standard deviations, indicating that MedFlowSeg is stable with respect to stochastic initialization and training variation.\n\nWe agree that a more complete statistical presentation would improve the manuscript. We are also considering adding mean and standard deviation results in Tables 1 and 2.\n\n> [Question 6] The results are hard to grasp here. There's a row-wise task and column-wise target task combination studied in this setup. But why though? eg. it doesn't make sense to study Echo-SegNet for gland segmentation in histopathology imagesm etc. I suggest the authors to please streamline the results a bit, i.e. keep the \"gray\" highlighted results only, to remove noisy results for no reason!\n\nWe thank the reviewer for this comment. Our goal was to compare how specific methods perform across different tasks, datasets, and imaging modalities, thereby revealing their task dependence and cross-task generalization. We agree that the full matrix may reduce readability and will streamline the main table by retaining only the gray-highlighted, task-relevant results.\n\n> [Question 7] I have a hard time reading much of a difference between MedSegDiffv2 and MedFlowSeg results here (the gains seem super marginal to claim robust predictions in uncertain regions). Can the authors back this with a qualitative heatmap for uncertain region's prediction for both models?\n\nSince the rebuttal system does not allow additional file or figure uploads, we cannot provide the requested heatmaps at this stage. We are considering improving the visualization in the revised manuscript by adding side-by-side uncertainty heatmaps.\n\n> [Question 8] I am assuming the section includes sampling steps for diffusion models until convergence? If that's the case, I think a fair number to put in would be per-step GFLOPs, and the average number of steps required per method to make the advantage of MedFlowSeg seem visible.\n\nWe thank the reviewer for this valuable suggestion. In the revised manuscript, we will add the per-step GFLOPs and the average number of sampling steps required by each method, providing a clearer and fairer comparison of computational efficiency."+ },+ "createdAt": "2026-07-28T11:31:05.933Z",+ "modifiedAt": "2026-11-18T17:17:42.829Z",+ "url": "https://openreview.net/forum?id=bf3XH3GbLU¬eId=MVjQ6L0C7y",+ "license": "CC-BY-4.0"+}
reviews/openreview/bf3xh3gblu/notes/ovdrquojh9.json added
+++ b/reviews/openreview/bf3xh3gblu/notes/ovdrquojh9.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "OVDRQUOjh9",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer nzj5",+ "content": {+ "summary": "The manuscript presents a novel generative segmentation method built on flow matching, called MedFlowSeg, to generative medical image segmentation. The key improvements are driven by two attention blocks, one for introducing strong structural priors, and another to model frequency-level information into the framework (and the ablation indeed speak for their integration).\n\nAlthough I am quite happy about the developed method (it's a very relevant method, considering the known stark advantage of flow matching for reducing sampling steps at inference time), without statistical significance experiments -- I am unsure if the reported results are stochastic (\"marginal\") gains over MedSegDiffv2 (which seems to be the current SOTA for generative medical image segmentation).\n\nSee comments below for more concerns!",+ "contribution_type": "general",+ "strengths_and_weaknesses": "See details below!",+ "quality": 3,+ "clarity": 2,+ "significance": 3,+ "originality": 4,+ "questions": "> ...achieving strong results on certain benchmarks while exhibiting limited generalization across different modalities and anatomical structures.\n\nAlthough the papers argue this statement is true for diffusion models in generative segmentation, they do not show any experiments to back this. I suggest the authors to either back these claims with empirical results for catastrophic failures, or tone down their preface for diffusion models.\n\n> ...are often tailored to specific tasks [4, 22], limiting their generalization across diverse modalities and segmentation scenarios.\n\nSame comment as above. Without empirical backing, it's unfair to make such assumptions. Can the authors either point me to the experiments, or please add such experiments to back their claims?\n\n> Moreover, the lack of explicit uncertainty modeling makes them less effective in handling irregular anatomical structures and ambiguous boundaries, leading to suboptimal results in challenging cases.\n\nAlthough this is mostly true, there's several efforts in context of probabilistic segmentation regime, in particular -- PUNet (https://arxiv.org/abs/1806.05034) and PhiSeg (https://arxiv.org/abs/1906.04045) are the two most successful ones. I suggest the authors investigate and report results of prior methods carefully and share experiments for generative segmentation paradigm prior to diffusion models.\n\n> Equation 4 and Equation 5\n\nReading the equation closely (with lambda and alpha parameter values): 1) Is there a rationale to chose fixed parameter values? 2) The effective value reads to me as Ltotal = Lvel + λLaux -- Ltotal = Lvel + λ (Ldice + αLce) -- Ltotal = Lvel + 0.1 (Ldice + 10 x Lce) -- **Ltotal = Lvel + 0.1 Ldice + Lce**\n\nIf it's downweighting dice loss at the end of the day with no particular reward to cross entropy, isn't the net balancing done by penalizing the dice further? I don't see the rationale for doing this. Do the authors have an ablation study to back such a choice?\n\n> Table 1:\n\nThe reported results do not seem statistically significant to me. Could you authors report the mean and standard deviation for a 5-fold training run across experiments? If the statistical significance is missing, it's hard to grasp if it's a stochastic run with incremental gains or it indeed performs well consistency!\n\n> Table 2:\n\nThe results are hard to grasp here. There's a row-wise task and column-wise target task combination studied in this setup. But why though? eg. it doesn't make sense to study Echo-SegNet for gland segmentation in histopathology imagesm etc. I suggest the authors to please streamline the results a bit, i.e. keep the \"gray\" highlighted results only, to remove noisy results for no reason!\n\n> Analysis of Uncertainty\n\nI have a hard time reading much of a difference between MedSegDiffv2 and MedFlowSeg results here (the gains seem super marginal to claim robust predictions in uncertain regions). Can the authors back this with a qualitative heatmap for uncertain region's prediction for both models?\n\n> Model Efficiency and Complexity\n\nI am assuming the section includes sampling steps for diffusion models until convergence? If that's the case, I think a fair number to put in would be per-step GFLOPs, and the average number of steps required per method to make the advantage of MedFlowSeg seem visible.",+ "limitations": "The only two highlights for me are: 1) missing experiments for classical generative segmentation experiments (using PUNet, PhiSeg), and 2) missing statistical significance of the proposed methods. There are several points to consider for the manuscript, see my comments above!",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "N/A",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "I'm happy about the discussions and presented additional results shared by the authors in the rebuttal and discussion period. And most, if not all, of the doubts are now clear after an engaging discussion."+ },+ "createdAt": "2026-06-26T06:05:20.131Z",+ "modifiedAt": "2026-11-18T13:40:42.285Z",+ "url": "https://openreview.net/forum?id=bf3XH3GbLU¬eId=OVDRQUOjh9",+ "license": "CC-BY-4.0"+}
reviews/openreview/bf3xh3gblu/notes/pmntmfgprs.json added
+++ b/reviews/openreview/bf3xh3gblu/notes/pmntmfgprs.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "pmntmFgprS",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "The paper proposes MedFlowSeg, a conditional flow-matching framework for generative medical image segmentation with dual spatial- and frequency-aware conditioning. The reviewers seem to view the problem as important, the method as reasonably original, and the evaluation across five modalities as broad, with good gains in efficiency relative to diffusion-based approaches [PgFc, jsmF, nzj5]. The most important unresolved issue is that the conditioning network is itself trained with a supervised Dice/CE segmentation loss while also receiving gradients through the flow-matching model, making it unclear how much of the final performance is due to flow matching rather than the conditioning branch alone [jsmF]. The rebuttal should prioritize clarifying the effects of such supervision and ideally what remains when the auxiliary Dice/CE supervision is removed or controlled. Other concerns include the lack of repeated-run statistics despite small margins over baselines, unclear fairness of preprocessing and multi-sample STAPLE comparisons, insufficient isolation of the frequency decomposition, and limited evidence for true 3D generalization and uncertainty advantages [PgFc, jsmF, nzj5].",+ "final_justification": "I would like to acknowledge that the reviewers and I read the responses offered by the authors. Based on reviewers' mostly positive responses and my own analysis of authors' rebuttals, most of the concerns raised in the reviews and the meta-review were convincingly addressed. Although the reviewer jsmF assigned a \"borderline reject\" score in their official review, agreed to raise the score to Accept following a discussion with the authors. Taking this into account, I am confident in recommending this paper for acceptance."+ },+ "createdAt": "2026-09-24T11:22:10.589Z",+ "modifiedAt": "2026-11-18T14:55:57.451Z",+ "url": "https://openreview.net/forum?id=bf3XH3GbLU¬eId=pmntmFgprS",+ "license": "CC-BY-4.0"+}
reviews/openreview/bf3xh3gblu/submission.json added
+++ b/reviews/openreview/bf3xh3gblu/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "bf3XH3GbLU",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 18321,+ "url": "https://openreview.net/forum?id=bf3XH3GbLU",+ "license": "CC-BY-4.0"+}
versions/v_9995qnph.json added
+++ b/versions/v_9995qnph.json@@ -0,0 +1,22 @@+{+ "date": "2026-05-03",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 18321,+ "url": "https://openreview.net/forum?id=bf3XH3GbLU",+ "reviews": "openreview/bf3xh3gblu",+ "evidence": [+ "https://openreview.net/forum?id=bf3XH3GbLU"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=bf3XH3GbLU",+ "evidence": [+ "https://openreview.net/forum?id=bf3XH3GbLU"+ ]+}