Import NeurIPS 2026 submission vCft9tPVmL: 8 notes
@openreview[bot] · 2026-11-22 18:00 UTC · 0c5bc1831bcb
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,23 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "vCft9tPVmL"+ }+ ],+ "title": "MT-CC: Multi-Group Temperature Scaling for Asymmetric Calibration Behavior in Class-Incremental Learning",+ "authors": [+ "Sungjun Yun",+ "Yonghee Choi",+ "Dong-Jun Han"+ ],+ "abstract": "As deep neural networks are required to continuously adapt to evolving data, class-incremental learning (CIL) has become an active research area. However, most existing works primarily focus on improving accuracy while overlooking confidence calibration, which measures the trustworthiness of the model's predictions. Although temperature scaling (TS) is effective for static calibration, it has rarely been explored in continual settings where data distributions evolve over time. In this paper, we introduce Multi-Group Temperature Scaling for Continual Calibration (MT-CC), a novel post-hoc calibration framework that addresses the asymmetric calibration behavior in CIL, where the rate of confidence changes does not align with the rate of accuracy degradation across tasks, leading to different levels of miscalibration. Our key contribution is to design multiple temperature parameters through a lightweight grouping network that separates samples by confidence statistics and task-aware signals in CIL. Furthermore, a Groupwise Difference-between-Confidence-and-Accuracy (GDCA) regularization is incorporated to promote intra-group consistency. Experiments demonstrate that MT-CC significantly improves calibration performance while maintaining accuracy, offering a principled framework for reliable continual learning.",+ "year": 2026,+ "venue": "NeurIPS 2026",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/vcft9tpvml/forms.json added
+++ b/reviews/openreview/vcft9tpvml/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/vcft9tpvml/notes/9ndkqesx83.json added
+++ b/reviews/openreview/vcft9tpvml/notes/9ndkqesx83.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "9ndkqEsx83",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer arsx",+ "content": {+ "summary": "The paper studies post-hoc confidence calibration in class-incremental learning. It argues that CIL models exhibit asymmetric calibration behavior because confidence and accuracy degrade at different rates across old and new tasks. The proposed MT-CC method assigns samples to multiple calibration groups using a lightweight grouping network based on softmax probabilities, normalized logit margin, old-class confidence, and new-class confidence. Each group receives its own temperature parameter, and a groupwise difference-between-confidence-and-accuracy regularizer is added to improve within-group calibration. Experiments cover CIFAR-10, CIFAR-100, Tiny-ImageNet, ImageNet, ImageNet-R, CNN and ViT backbones, several replay-based CIL methods, and multiple calibration metrics.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths\n\nS1. The paper addresses an important aspect of continual learning that is often secondary to accuracy. Confidence reliability after incremental updates is practically important, especially when old-task accuracy degrades while confidence remains high.\n\nS2. The method is simple and efficient. It preserves classification accuracy because it is a post-hoc temperature-scaling method, and the reported inference overhead is negligible relative to standard temperature scaling.\n\nS3. The empirical coverage is broad. The paper compares against vanilla predictions, TS, ETS, IRM, PTS, AdaTS, T-CIL, and combinations of T-CIL with several calibration methods. It also includes ImageNet-scale results, ViT-based results, validation-size sensitivity, replay-memory sensitivity, group-number ablations, compatibility with EEIL, BiC, iCaRL, IL2M, and DER, and reliability diagrams.\n\nS4. The reported ECE and AECE improvements are meaningful in several settings. For example, MT-CC improves CIFAR-100 ECE from 6.03 for T-CIL to 4.49, Tiny-ImageNet ECE from 18.96 to 15.82, and ImageNet ER with a 20K buffer from 10.57 to 8.44.\n\nWeaknesses\n\nStrong Weaknesses\n\nW1. The conceptual novelty is moderate. Multi-temperature or input-dependent calibration is a natural extension of temperature scaling, and the proposed grouping network is a shallow supervised router over confidence statistics. The old/new confidence features are appropriate for CIL, but the paper should more clearly distinguish the contribution from grouped calibration, mixture temperature scaling, and instance-wise temperature scaling under a matched feature budget.\n\nW2. The labeled validation-data assumption is central and insufficiently discussed. MT-CC splits a validation set into grouping and calibration subsets and uses the T-CIL validation-generation framework in the main experiments. In practical CIL settings, labeled validation data for old and new classes may be scarce or unavailable. The paper should precisely state what labels are required after each task, how augmented validation data are generated, and whether old-class validation examples are retained.\n\nW3. Some claims are overstated relative to the tables. In Table 1, MT-CC is not uniformly the best on SCE: T-CIL+ETS achieves better SCE on CIFAR-100, and T-CIL+IRM achieves better SCE on Tiny-ImageNet. Table 4 also shows that removing the logit margin slightly improves CIFAR-10 ECE relative to the full model. These are not fatal issues, but the text should be more precise.\n\nW4. The evaluation relies heavily on ECE-style metrics with 10 bins. Additional metrics such as NLL, Brier score, risk coverage, top-label calibration, and sensitivity to the bin count would provide a more complete picture of reliability under severe forgetting and class imbalance.\n\nWeak Weaknesses\n\nW5. The grouping input includes the full softmax vector, so its dimensionality grows with the number of classes. The paper should clarify how the grouping network is handled as the label space expands over long streams.\n\nW6. The limitations section is brief and does not address the labeled calibration data requirement, metric sensitivity, or the empirical and post hoc nature of the contribution.",+ "quality": 3,+ "clarity": 4,+ "significance": 4,+ "originality": 3,+ "questions": "Q1. Can the authors revise the text where it says MT-CC is best across all calibration metrics, given the SCE exceptions in Table 1?\n\nQ2. What exact labeled calibration data are required after each incremental task? Please describe the source of Sgrp and Scal, whether old-class labels are available, and how the validation-size-zero setting should be interpreted.\n\nQ3. Can the authors compare against a feature-matched grouped or mixture temperature baseline using the same softmax, margin, and old/new confidence inputs but without the proposed optimization procedure or GDCA?\n\nQ4. How sensitive are the results to ECE bin count and to alternative metrics such as NLL and Brier score?\n\nQ5. Is a new grouping network trained at every task with a growing softmax input dimension, or is there a fixed-dimensional representation used internally?",+ "limitations": "yes",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "-",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The rebuttal addresses my concerns through feature-matched and grouped calibration baselines, clarification of the labeled validation protocol, additional Brier-score and ECE-bin analyses, and an explanation of the grouping network’s scalability. The authors also appropriately correct the overstated claims. Although the method still relies on labeled current-task validation data and remains primarily an empirical post hoc contribution, the added evidence significantly strengthens the paper. I therefore raise my rating to Accept."+ },+ "createdAt": "2026-06-26T00:55:00.629Z",+ "modifiedAt": "2026-11-18T13:41:15.956Z",+ "url": "https://openreview.net/forum?id=vCft9tPVmL¬eId=9ndkqEsx83",+ "license": "CC-BY-4.0"+}
reviews/openreview/vcft9tpvml/notes/au1cxslptc.json added
+++ b/reviews/openreview/vcft9tpvml/notes/au1cxslptc.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "AU1cXsLPTC",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer 4uJM",+ "content": {+ "summary": "Continual shifts in class-incremental learning may cause old and new task groups to exhibit distinct confidence characteristics. Existing CIL calibration methods often rely on a single temperature value, which may not be sufficient to handle this asymmetric miscalibration behavior. To address this, the paper proposes MT-CC, a multi-group temperature scaling method that assigns samples to different calibration groups using confidence statistics, margin information, and old/new task confidence signals. Each group is then calibrated with its own temperature parameter, allowing the method to adjust confidence more flexibly across different types of samples. The paper also introduces a groupwise confidence-accuracy regularization term to further align the average confidence and accuracy within each group.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strength:\nI find the problem studied in this paper important. Calibration in class-incremental learning is often overlooked, even though a continually trained model may become unreliable in its confidence estimates as new classes are introduced. The paper clearly motivates this issue by showing that old and new tasks can exhibit different confidence-accuracy gaps, making a single global temperature potentially insufficient. I also appreciate that the authors do not only propose a method, but also explicitly discuss why existing post-hoc calibration methods and CIL-specific calibration methods may be suboptimal in this setting. The proposed solution is simple and intuitive: route samples into different calibration groups and assign group-specific temperatures based on confidence-related signals.\n\nWeakness:\nMy main concern is that, although the paper is strongly motivated from a CIL perspective, it is not fully clear how much of the proposed method is genuinely CIL-specific rather than a generic adaptive/group-wise calibration method applied to CIL. The core idea of assigning samples to different temperature groups can also be used in a standard static classification setting, where samples may naturally have different calibration behavior based on confidence, margin, entropy, or class-wise statistics. In this paper, the main CIL-specific signal appears to be the old/new confidence pair, $(p_{\\text{old}})$ and $(p_{\\text{new}})$, which uses the known task order to summarize the probability mass over previous and current classes.\n\nHowever, the ablation does not convincingly show that this CIL-specific signal is consistently crucial. Removing the old/new confidence, the drop is relatively small on CIFAR-10 and especially marginal on CIFAR-100. This makes it unclear whether the gains mainly come from modeling CIL-specific old/new asymmetry, or from a more generic adaptive temperature scaling mechanism. A stronger analysis would compare against generic grouping baselines that use only confidence, margin, entropy, or predicted-class statistics, and would also report old-task versus new-task calibration errors separately.\n\nAnother concern is the learned grouping network itself. Since the grouping network is updated across tasks, it may also suffer from forgetting or distributional drift. Although replay samples are used during calibration, the paper does not analyze whether the learned grouping function remains stable for old-task samples after later tasks. In particular, it is unclear whether updating the grouping network on later tasks changes the routing behavior of old samples in a harmful way. The paper also does not clearly define what makes the replay or calibration samples informative for learning the grouping function, beyond relying on representative replay samples or T-CIL-generated calibration data. An analysis of routing consistency over time, old-task group assignment changes, or the effect of freezing versus continually updating the grouping network would make the method more convincing.",+ "quality": 3,+ "clarity": 2,+ "significance": 3,+ "originality": 2,+ "questions": "Please see the concerns outlined in the weakness section. I am willing to increase my score if the authors can adequately address these issues.",+ "limitations": "yes",+ "rating": 4,+ "confidence": 2,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "N/A",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "I have carefully read the rebuttal and have decided to increase my score."+ },+ "createdAt": "2026-06-25T00:47:31.236Z",+ "modifiedAt": "2026-11-18T13:41:16.786Z",+ "url": "https://openreview.net/forum?id=vCft9tPVmL¬eId=AU1cXsLPTC",+ "license": "CC-BY-4.0"+}
reviews/openreview/vcft9tpvml/notes/ed5ho0e0ey.json added
+++ b/reviews/openreview/vcft9tpvml/notes/ed5ho0e0ey.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "Ed5HO0E0Ey",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer edFr",+ "content": {+ "summary": "This paper proposes MT-CC, a post-hoc calibration framework for class-incremental learning. The method is motivated by the observation that old and new tasks may exhibit different confidence-accuracy gaps after continual training, making a single global temperature insufficient. MT-CC uses a lightweight grouping network conditioned on the softmax probabilities, logit margin, and old/new class probability mass to assign each sample to a calibration group with a group-specific temperature. The authors further introduce a groupwise difference-between-confidence-and-accuracy loss to improve calibration within each group. Experiments show consistent calibration improvements without modifying classification accuracy.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "The paper is clearly written and addresses an important but relatively underexplored problem in class-incremental learning. The proposed method is lightweight, post-hoc, and can be applied to different CIL models without modifying their original training procedure or classification accuracy. The reported results consistently improve upon existing calibration methods, including the CIL-specific T-CIL baseline. The ablation studies also provide useful evidence regarding the contributions of the grouping features and GDCA regularization.\n\nMy weakness rates are as follows:\n\nHeuristic Grouping Design with Limited Methodological Justification.\n\nThe proposed grouping mechanism appears largely heuristic. The number of groups is fixed to two, and the router relies on manually selected statistics, including the old/new probability mass and the logit margin. While these choices are empirically effective, the paper provides limited principled justification for why two groups are sufficient, why these specific statistics are the most appropriate indicators of miscalibration. Similarly, the claim that GDCA stabilizes the coupled routing temperature optimization is supported mainly through empirical observations. Overall, the method appears closer to an effective empirical recipe than a fundamentally new calibration principle.\n\nUnclear Relationship Between the Claimed Old/New Asymmetry and the Learned Groups\n\nThe motivation of MT-CC is based on asymmetric miscalibration between old and new tasks. However, the grouping behavior shown in Figure 3 does not clearly correspond to an old/new partition: the higher temperature group contains not only most new task samples but also a substantial portion of old task samples. This may indicate that the grouping network primarily captures generic sample difficulty or confidence patterns rather than the proposed old/new calibration asymmetry. Therefore, it remains unclear which behavior actually drives the performance improvement.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 2,+ "questions": "Please refer to weaknesses.",+ "limitations": "yes",+ "rating": 4,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "I have read the rebuttal and carefully considered the authors' responses. Some concerns regarding the heuristic nature remain, particularly regarding the discrete grouping formulation and the role of old/new asymmetry. Nevertheless, the additional analyses provide substantially stronger empirical justification for the design choices and address most of my original concerns. Consequently, I have decided to raise my rating to borderline accept."+ },+ "createdAt": "2026-06-26T10:43:29.173Z",+ "modifiedAt": "2026-11-18T13:41:14.702Z",+ "url": "https://openreview.net/forum?id=vCft9tPVmL¬eId=Ed5HO0E0Ey",+ "license": "CC-BY-4.0"+}
reviews/openreview/vcft9tpvml/notes/efnfkfw83m.json added
+++ b/reviews/openreview/vcft9tpvml/notes/efnfkfw83m.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "efnFKfW83M",+ "replyTo": "AU1cXsLPTC",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We sincerely thank the reviewer for the careful and constructive feedback.\n\n# W1. Applicability to Static Classification\nWe appreciate the comment. We agree that group-wise temperature scaling itself is not inherently CIL-specific. To confirm whether MT-CC benefits simply from using multiple temperatures, we applied the identical pipeline to a jointly trained static CIFAR-100 model and reported results over five seeds.\n|Setting|Single-T ECE|MT-CC ECE|\n|-|-|-|\n|Static, joint|0.87±0.14|0.87±0.14|\n|CIL, task-avg|6.03±0.42|4.49±0.53|\n\nIn the static setting, the router collapses to a single effective group (min-group-fraction = 0.000 ± 0.000), and that group's fitted temperature matches the single-temperature solution to within 0.003 in every seed. MT-CC therefore reduces to single-temperature scaling rather than providing a clear benefit in the static setting. Under CIL, the same pipeline instead separates samples into distinct calibration regimes and reduces ECE from 6.03 to 4.49. This suggests that the gain of MT-CC does not arise merely from introducing multiple temperatures, but by capturing the heterogeneous calibration behavior induced by continual learning.\n\n# W2. CIL-Induced Calibration Signals and Learned Groups\n\nWe would like to clarify that the old/new asymmetry in Fig. 2 motivates heterogeneous calibration under CIL, but **MT-CC is not designed to exactly reconstruct an old/new partition**. Fig. 2 reports task-wise average confidence–accuracy gaps; substantial sample-level heterogeneity can still exist within each task.\n\nAccordingly, MT-CC combines multiple signals that capture different aspects of CIL-induced miscalibration. While $p_{\\mathrm{old}}$ and $p_{\\mathrm{new}}$ explicitly encode the continual class structure, the **logit margin signal captures another important effect that emerges under CIL**. To examine this, we divide samples into 10 equal-count margin bins and independently fit the NLL-optimal temperature T∗ in each bin.\n\n|Setting|b0 (lowest)|b1|b2|b3|b4|b5|b6|b7|b8|b9 (highest)|\n|-|-|-|-|-|-|-|-|-|-|-|\n|Static|1.98±0.04|1.99±0.05|2.00±0.04|1.95±0.04|2.00±0.05|1.94±0.03|1.96±0.02|1.92±0.04|2.04±0.08|2.10±0.14|\n|CIL|1.58±0.08|1.68±0.12|1.77±0.05|1.84±0.08|2.00±0.13|2.13±0.06|2.36±0.12|2.59±0.15|2.99±0.13|3.82±0.12|\n\nIn the static model, T∗ remains nearly constant across margin regions. Under CIL, it increases markedly from 1.58 to 3.82, showing that samples with different margins require substantially different calibration corrections. Thus, the logit margin signal exposes calibration heterogeneity that becomes pronounced after continual learning.\n\nWe further isolate the contribution of each routing signal:\n\n|Grouping-network input| ECE↓|AECE↓|Brier↓|\n|-|-|-|-|\n|confidence|5.76±0.26|5.76±0.22|0.569±0.006|\n|confidence + margin|4.63±0.30|4.65±0.26|0.571±0.007|\n|confidence + old/new|4.95±0.37|4.93±0.34|0.560±0.008|\n|confidence + margin + random class-mass pair|4.60±0.38|4.61±0.30|0.571±0.007|\n|**confidence + margin + true old/new pair (MT-CC)**|**4.49±0.53**|**4.44±0.49**|**0.556±0.006**|\n\nHere ($p_{\\mathrm{old}}$, $p_{\\mathrm{new}}$) is the predicted probability mass on old versus new classes; the random variant replaces the old/new split with a random class partition whose two subsets match the true old and new class counts, so the two differ only in which classes are grouped together. Confidence and margin already capture much of the calibration heterogeneity, while the true old/new statistics provide a further improvement: the random partition yields 4.60 ECE, close to confidence + margin alone (4.63), whereas the task-aligned pair achieves the best mean ECE, AECE, and Brier.\n\nImportantly, these signals are not intended to recover task identity. **Table 6 in our manuscript** directly supports this distinction: despite using oracle ground-truth task information, GT Old/New TS and GT Per-task TS achieve 5.97 and 5.91 ECE, respectively, while MT-CC achieves 4.49. Thus, old/new asymmetry motivates heterogeneous calibration, but the learned calibration regimes does not coincide with old/new or per-task boundaries, motivating the need of other signals. We will clarify this interpretation in the revised manuscript.\n\n# W3. Comparison with Generic Adaptive Calibration\nTo separate the contribution of the routing features from the calibration mechanism, we evaluate PTS and AdaTS using both their original inputs and the feature vector used by MT-CC (confidence, margin, $p_{\\mathrm{old}}$, $p_{\\mathrm{new}}$). Throughout this section, \"CIL-aware features\" refers to exactly this vector. We also introduce **K-means Group-TS (K=2)**, which applies unsupervised K-means to the same features followed by group-wise temperature scaling.\n\n|Method|Calibration/Routing|Feature Setting|ECE ↓|AECE ↓|Brier ↓|\n|-|-|-|-|-|-|\n|PTS|Instance-wise TS|top-10 logits|9.87±0.77| 10.14±0.67|0.596±0.008|\n|PTS|Instance-wise TS|CIL-aware features|6.88±0.91 | 6.87±0.91|0.575±0.008|\n|AdaTS|Instance-wise TS|penultimate feature|7.67±0.52 | 7.66±0.49|0.586±0.004|\n|AdaTS|Instance-wise TS|CIL-aware features|6.55±0.74 | 6.52±0.75|0.574±0.004|\n|K-means Group-TS|K-means (K=2) + group-wise TS|CIL-aware features|5.41±0.51|5.37±0.51|0.561±0.005|\n|**MT-CC**|Learned routing + group-wise TS|CIL-aware features|**4.49±0.53**|**4.44±0.49**|**0.556±0.006**|\n\nUsing the MT-CC features improves PTS from 9.87 to 6.88 ECE and AdaTS from 7.67 to 6.55, confirming that these signals are themselves useful for calibration. K-means Group-TS further improves ECE to 5.41. However, with the feature set fixed, MT-CC achieves 4.49 ECE together with the best mean AECE and Brier score. Thus, neither the input features alone nor generic two-group clustering fully explains the improvement.\n\nWe further examine the resulting groups at the final CIFAR-100 task, averaged over five seeds. Groups are ordered by increasing temperature.\n\n|Method|Group|Old/New ratio|Group T|ECE @ Group T|ECE @ T-CIL T|\n|-|-|-|-|-|-|\n|**MT-CC**|G1|98.5 / 1.5%|2.130±0.093|**3.98±1.65%**|7.66±2.94%|\n||G2|79.1 / 20.9%|2.983±0.137|**20.80±3.75%**|33.36±3.26%|\n|K-means Group-TS|G1|99.0 / 1.0%|2.198±0.092|8.26±1.56%|12.31±1.59%|\n||G2|81.4 / 18.6%|2.683±0.078|26.48±1.81%|32.19±2.30%|\n\nBoth methods identify groups with different old/new compositions, but neither simply reproduces an old/new partition.\nMore importantly, keeping the group assignments fixed and applying T-CIL's single temperature consistently increases the group-wise ECE, showing that a single global temperature is insufficient for these subpopulations. The same pattern appears under the K-means partition, indicating that this effect is not specific to the MT-CC router.\n\nFor clarity, group-wise ECEs do not sum to the pooled ECE because ECE is recomputed after pooling samples into confidence bins rather than averaged across group-wise ECEs. At the final task, MT-CC has a pooled ECE of 7.97±2.13%.\nWe will include these comparisons and group-level analyses in the revised manuscript.\n\n# W4. Continual Update of the Grouping Network & Grouping Behavior\n\nWe examine continual updates of the grouping network and compare three strategies on CIFAR-100 over five seeds:\n\n* **MT-CC:** carries the router from task t−1 to task t and updates it using the current calibration data.\n* **Lag-1:** uses the router obtained after task t−1 for evaluating task t, while re-fitting only the group temperatures.\n* **Fresh each task:** reinitializes and trains the router independently at every task.\n\n|Grouping-network strategy | ECE ↓ | AECE ↓ | SCE‰ ↓ | Brier ↓ |\n|-|-|-|-|-|\n|**MT-CC**|**4.49±0.53**|**4.44±0.49**|**5.62±0.11**|**0.556±0.006**|\n|Lag-1|4.82±0.36|4.82±0.36|5.70±0.12|0.558±0.006|\n|Fresh each task|4.98±0.35|4.96 ± 0.34|5.78±0.14|0.561±0.007|\n\nLag-1 isolates the effect of adapting the previous router to the current task: updating it reduces ECE from 4.82 to 4.49. Conversely, reinitializing the router at every task degrades ECE to 4.98, indicating that previously learned routing information is also useful. Thus, MT-CC benefits from both retention and continual adaptation of the router.\n\nWe further measure **routing consistency** across adjacent sessions, averaged over all transitions and five seeds. Groups are ordered by temperature, with G1 denoting the low-temperature group and G2 the high-temperature group. Group retention is the fraction of samples assigned to each group under the earlier routing that remain in that group under the later routing. We compare the actual transition, where both the classifier and router evolve from session t−1 to t, with a controlled condition in which the session-t classifier outputs are held fixed and the routers from sessions t−1 and t are evaluated on the same classifier outputs.\n\n|Condition|G1 retention|G2 retention|\n|-|-|-|\n|Classifier + router change (actual)|71.8±7.5%|42.0±12.4%|\n|Router change only (classifier fixed)|94.3±6.3%|90.3±9.5%|\n\nAlthough raw assignments change as continual learning progresses, adjacent-session routers retain more than 90% of assignments when evaluated on the same classifier outputs. Thus, the lower retention in the actual transitions largely reflects changes in the evolving classifier outputs rather than instability caused by updating the router itself.\n\n# W5. Why the Generated Calibration Samples Are Informative\n\nIn CIL, the current-task validation set contains only new classes and therefore does not reflect the calibration behavior of previously learned classes.\n\nFollowing T-CIL, we use replay exemplars to generate new calibration samples. These samples allow MT-CC to learn confidence–correctness patterns across both old and new classes without storing separate validation sets from previous tasks. T-CIL and MT-CC use the same generated calibration data, ensuring that the comparison isolates the effect of MT-CC's grouping and group-specific temperature scaling. \n\nWe will clarify all these points in the revision. Thanks again for your time and feedback."+ },+ "createdAt": "2026-07-26T10:12:23.917Z",+ "modifiedAt": "2026-11-18T17:18:13.453Z",+ "url": "https://openreview.net/forum?id=vCft9tPVmL¬eId=efnFKfW83M",+ "license": "CC-BY-4.0"+}
reviews/openreview/vcft9tpvml/notes/jukobecgbp.json added
+++ b/reviews/openreview/vcft9tpvml/notes/jukobecgbp.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "jUkoBEcgBp",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair 1HAN",+ "content": {+ "metareview": "MT-CC tackles the relatively underexplored problem of confidence calibration in class-incremental learning by proposing a post-hoc multi-group temperature scaling strategy that adapts the calibration temperature based on a lightweight grouping network and a groupwise confidence-accuracy regularization term. The reviewers appreciate that the paper focuses on an important practical issue that is often overshadowed by accuracy, and they find the approach appealing due to its simplicity, low computational overhead, and broad empirical evaluation across multiple datasets, backbones, and continual learning methods.\n\nAt the same time, the discussion converges around several issues that should be addressed before the contribution can be fully assessed. A recurring question is whether the proposed method is genuinely tailored to class-incremental learning or whether it is primarily a generic adaptive temperature scaling technique applied in a CIL setting. In particular, the authors should better demonstrate that the old/new calibration asymmetry is indeed the key mechanism behind the observed improvements, rather than the grouping strategy simply capturing generic confidence or sample difficulty. Related to this, the methodological choices behind the grouping network—including the selected features, the use of two groups, and the GDCA regularization—would benefit from stronger justification beyond empirical effectiveness. The reviewers also ask for greater clarity regarding the assumptions on labeled validation data, the scalability of the grouping network as the number of classes grows, and the robustness of the reported gains under alternative calibration metrics and evaluation settings."+ },+ "createdAt": "2026-07-16T08:00:30.151Z",+ "modifiedAt": "2026-11-18T15:22:43.349Z",+ "url": "https://openreview.net/forum?id=vCft9tPVmL¬eId=jUkoBEcgBp",+ "license": "CC-BY-4.0"+}
reviews/openreview/vcft9tpvml/notes/rtdjvwbzvh.json added
+++ b/reviews/openreview/vcft9tpvml/notes/rtdjvwbzvh.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "rTdjvWbzVh",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (spotlight)",+ "comment": "",+ "metareview": "MT-CC tackles the relatively underexplored problem of confidence calibration in class-incremental learning by proposing a post-hoc multi-group temperature scaling strategy that adapts the calibration temperature based on a lightweight grouping network and a groupwise confidence-accuracy regularization term. The reviewers appreciate that the paper focuses on an important practical issue that is often overshadowed by accuracy, and they find the approach appealing due to its simplicity, low computational overhead, and broad empirical evaluation across multiple datasets, backbones, and continual learning methods.\n\nAt the same time, the discussion converges around several issues that should be addressed before the contribution can be fully assessed. A recurring question is whether the proposed method is genuinely tailored to class-incremental learning or whether it is primarily a generic adaptive temperature scaling technique applied in a CIL setting. In particular, the authors should better demonstrate that the old/new calibration asymmetry is indeed the key mechanism behind the observed improvements, rather than the grouping strategy simply capturing generic confidence or sample difficulty. Related to this, the methodological choices behind the grouping network—including the selected features, the use of two groups, and the GDCA regularization—would benefit from stronger justification beyond empirical effectiveness. The reviewers also ask for greater clarity regarding the assumptions on labeled validation data, the scalability of the grouping network as the number of classes grows, and the robustness of the reported gains under alternative calibration metrics and evaluation settings.",+ "final_justification": "The rebuttal has convincingly explained the CIL-specific nature of the proposed method, and clarified the practical assumptions behind the calibration procedure. Furthermore, the justification for the main design decisions as well as the correction of over-stated claims have convinced the reviewers to increase the scores. Therefore, I recommend the acceptance of this paper and given it's interesting approach to CIL, I think it can be a spotlight."+ },+ "createdAt": "2026-09-24T11:22:47.572Z",+ "modifiedAt": "2026-11-18T14:56:24.031Z",+ "url": "https://openreview.net/forum?id=vCft9tPVmL¬eId=rTdjvWbzVh",+ "license": "CC-BY-4.0"+}
reviews/openreview/vcft9tpvml/notes/v4pdb8lyso.json added
+++ b/reviews/openreview/vcft9tpvml/notes/v4pdb8lyso.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "V4PDb8LysO",+ "replyTo": "Ed5HO0E0Ey",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We sincerely thank the reviewer for the time and feedback.\n# W1-a. Number of Groups\nWe appreciate the comment. Appendix E.1 of our paper reports a sweep over the number of groups M; we extend it here to M = 5 on CIFAR-100 over five seeds (M = 1 corresponds to single-temperature scaling, i.e. T-CIL).\n|M|ECE↓|AECE↓| Brier↓|\n|-|-|-|-|\n|1 (T-CIL)|6.03±0.42|6.04±0.35|0.570±0.005|\n|2 |4.49±0.53|4.44±0.49|0.556±0.006|\n|3|4.51±0.47|4.48±0.45|0.558±0.007|\n|4|4.50±0.41|4.50±0.42|0.559±0.007|\n|5|4.79±0.40|4.77±0.41|0.561±0.007|\n\nThe sweep shows that nearly all gain comes from M=1→2 (6.03→4.49 ECE); M=3,4 are indistinguishable from M=2 across metrics, while M=5 degrades. Thus, **our choice of (M=2) is based on the observed saturation of performance rather than evaluating only two groups**. One possible reason is that increasing M introduces more group-specific temperatures to optimize, making the joint routing-temperature optimization more complex. At the same time, the calibration data are partitioned among more groups, leaving fewer samples to reliably estimate each temperature, particularly for sparsely populated groups. Consistent with these explanations, for (M>2), routing often concentrates on two groups while the others remain sparsely populated.\n# W1-b. Justification of Routing Statistics\nThank you for pointing this out. We choose the key statistics because they **capture complementary sources of calibration heterogeneity under CIL**: **(i)** margin reflects variation in the amount of temperature correction required across samples, **(ii)** confidence provides additional calibration information even after margin is controlled, and **(iii)** old/new probability masses capture CIL-specific structure beyond generic class-mass statistics.\n\nWe first examine whether the required calibration temperature depends on the logit margin signal. For both a jointly trained static CIFAR-100 model and the CIL model at the final task, we divide samples into 10 equal-count margin bins and independently fit the NLL-optimal temperature $T^* $ in each bin, averaged over five seeds.\n\n|Setting|b0 (low)|b1|b2|b3|b4|b5|b6|b7|b8|b9 (high)|\n|-|-|-|-|-|-|-|-|-|-|-|\n|Static|1.98|1.99|2.00|1.95|2.00|1.94|1.96|1.92|2.04|2.10|\n|CIL|1.58|1.68|1.77|1.84|2.00|2.13|2.36|2.59|2.99|3.82|\n\nIn the static model, $T^* $ remains nearly constant across margin bins, even though accuracy increases from 0.29 to 0.99 as the margin grows. **Under CIL, however,** $T^* $ **varies substantially from 1.58 to 3.82.** Moreover, the highest-margin bin has only 0.21 accuracy, showing that a large margin no longer reliably indicates correctness and can instead correspond to severe overconfidence. Thus, margin is not merely a proxy for generic sample difficulty. Under CIL, it becomes strongly associated with the calibration correction required by different samples.\n\nWe next ask whether margin alone is sufficient. If the optimal temperature were determined only by margin, confidence should add little information once margin is controlled. We therefore divide samples into two equal-count margin regions and, within each region, split them into low- and high-confidence halves. We fit $T^* $ independently to each subset and define $\\Delta T^* $ as the difference between the high- and low-confidence optimal temperatures.\n|Setting|Margin region|Low-conf. $T^*$ |High-conf. $T^*$|$\\Delta T^*$|\n|-|-|-|-|-|\n|Static|Low|1.98|1.99|0.01|\n||High|1.94|2.03|0.09|\n|CIL|Low|1.60|1.95|0.34|\n||High|2.26|3.32|1.05|\n\nAfter controlling for margin, **confidence adds little temperature information in the static model** $\\Delta T^*$=0.01/0.09 **but substantially more under CIL (0.34/1.05)**. Thus, margin and confidence capture complementary aspects of CIL-induced calibration heterogeneity.\n\n**The old/new probability masses capture CIL-specific structure beyond generic class-mass statistics**. To test whether their benefit comes merely from providing two additional class-mass statistics, we replace the old/new probability masses with masses computed from a random partition of the classes, while matching the two subset sizes to the true old/new split.\n|Grouping-network input|ECE↓|AECE↓|Brier↓|\n|-|-|-|-|\n|random class-mass pair|4.60|4.61|0.571|\n|true old/new pair (MT-CC)|4.49|4.44|0.556|\n\nThe true old/new partition consistently improves all metrics, suggesting that it captures calibration-relevant CIL structure. We will include these analyses in our revised manuscript.\n# W1-c. Role of GDCA in MT-CC\nWe appreciate this concern. GDCA is introduced because NLL alone can provide a weak learning signal for the router, whereas GDCA directly evaluates the confidence–accuracy mismatch within each learned group and therefore provides a complementary calibration-sensitive routing signal.\n\nFirst, the joint NLL weakly identifies routing when the group temperatures are similar. Stage 1 jointly optimizes the router $w_g(x)$ and group temperatures $\\tau_g$ through $p(y\\mid x)=\\sum_g w_g(x)\\\\mathrm{softmax}(z(x)/\\tau_g)$.\n\nWhen $\\tau_1=\\tau_2$, this expression is independent of the routing weights, so $\\nabla_{\\theta_W}\\mathcal{L}_{\\mathrm{NLL}}=0$. Our pipeline initializes at $\\tau_1=\\tau_2=1.5$, exactly at this point. Numerically, the router-gradient norm is $2.0\\times10^{-9}$, whereas the temperature-gradient norm is $2.93\\times10^{-1}$. As the temperatures separate by 1%, 5%, and 20%, the router-gradient norm increases to $1.64\\times10^{-3}$, $8.27\\times10^{-3}$, and $3.14\\times10^{-2}$, respectively. Thus, the routing signal from NLL depends strongly on temperature separation.\n\nSecond, this ambiguity is not limited to initialization. Even after re-optimizing the temperatures for a given routing, clearly different routing solutions can achieve nearly identical NLL. To examine this, we perturb the learned routing and re-optimize the temperatures from scratch at each point.\n|Profile-likelihood analysis|Result|\n|-|-|\n|ECE spread within a 0.1% NLL band|0.70 pts avg. / 1.31 pts max|\n|NLL cost of complete routing collapse|+1.31%|\n|ECE cost of complete routing collapse|+2.19 pts|\n\nThus, NLL can assign similar objective values to routing solutions with noticeably different calibration quality. This is precisely where GDCA provides complementary information: rather than evaluating only the likelihood of the final prediction, GDCA measures the confidence–accuracy discrepancy within each routed group. A routing that mixes samples with different calibration behaviors therefore incurs a larger groupwise calibration discrepancy even when its optimized NLL remains similar.\n\nConsistent with this interpretation, adding GDCA is associated with less degenerate routing behavior over five seeds and nine continual sessions:\n|Routing behavior|w/o GDCA|with GDCA| \n|-|-|-|\n|Minority group <20%|20.0%|4.4%|\n|Mean minority-group fraction|0.297|0.375|\n|Fraction vs. session slope|-0.02|+0.01|\n\nWithout GDCA, the minority-group fraction tends to decrease as continual learning progresses, whereas this trend is not observed when GDCA is included. These results suggest that GDCA helps prevent the router from progressively concentrating samples into a single dominant group. We therefore refine our claim as follows: **NLL alone can weakly distinguish routing solutions that differ in calibration quality**, while GDCA supplies an explicit group-level confidence–accuracy criterion that complements the NLL objective during router learning.\n# W2. Relationship Between the Old/New Asymmetry and the Learned Groups\nAs the reviewer pointed out, the learned groups in Figure 3 do not correspond to a hard old/new partition. This is expected, as **MT-CC is not intended to exactly separate old/new samples.** However, this does not mean that MT-CC captures only generic sample difficulty or confidence patterns.\n\nFigure 2 shows distinct old/new calibration behaviors, but this asymmetry is not uniform across samples. For example, some old-task samples remain well calibrated while others require much stronger correction, making a hard old/new temperature split too coarse.\n\nInstead, MT-CC uses the old/new probability masses to incorporate this CIL-specific signal, while softmax probabilities and logit margin further distinguish samples requiring different calibration corrections. Consequently, some old and new samples can belong to the same group when they require similar temperature adjustments. Thus, the mixed groups refine the old/new asymmetry at the sample level rather than replacing it with generic difficulty grouping.\n\nWe examine the learned groups at the final CIFAR-100 task, averaged over five seeds. The overall old/new test ratio at this stage is approximately 90/10, and groups are ordered by increasing temperature.\n|Method|Group|Old/New ratio|Group T|ECE @ Group T|ECE @ T-CIL T|\n|-|-|-|-|-|-|\n|MT-CC|G1|98.5/1.5%|2.13|3.98|7.66|\n||G2|79.1/20.9%|2.98|20.80|33.36\n\nThe groups do not exactly reproduce an old/new partition, but their compositions are clearly associated with it. New-task samples account for 20.9% of the high-temperature group, roughly twice their 10% share in the overall test set, while the low-temperature group is almost entirely composed of old-task samples. Keeping these assignments fixed while replacing each group-specific temperature with T-CIL’s global temperature substantially increases ECE in both groups, indicating that the learned subpopulations require different calibration corrections.\n\nOur results further support this interpretation. Replacing the old/new probability masses with a matched random class partition degrades performance, confirming that the old/new structure contributes to the learned grouping. At the same time, GT Old/New TS and GT Per-task TS achieve ECEs of 5.97 and 5.91, respectively, compared with 4.49 for MT-CC, showing that task identity alone is too coarse. Thus, MT-CC addresses the old/new calibration asymmetry more precisely by resolving it into sample-level calibration groups rather than a hard task partition."+ },+ "createdAt": "2026-07-27T11:50:13.813Z",+ "modifiedAt": "2026-11-18T17:18:13.543Z",+ "url": "https://openreview.net/forum?id=vCft9tPVmL¬eId=V4PDb8LysO",+ "license": "CC-BY-4.0"+}
reviews/openreview/vcft9tpvml/notes/zg3r79939z.json added
+++ b/reviews/openreview/vcft9tpvml/notes/zg3r79939z.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Zg3R79939Z",+ "replyTo": "9ndkqEsx83",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We sincerely thank the reviewer for their time, effort, and feedback.\n\n# W1/Q3. Novelty of MT-CC: CIL-Aware Features and Calibration Formulation\n\nWe appreciate the comment. Our contribution is not simply introducing multiple temperatures, but **identifying and addressing a CIL-specific calibration challenge that existing post-hoc calibration methods do not explicitly model.** As shown in Figure 2, catastrophic forgetting causes the accuracy and confidence of previously learned and newly introduced classes to evolve differently over successive tasks, resulting in asymmetric calibration behavior.\n\nTo address this challenge, MT-CC introduces **CIL-aware calibration statistics** — the **logit margin** and the **probability masses assigned to old and new classes** — together with a **calibration-aware grouping framework**. The old/new masses characterize how confidence shifts between previously learned and newly introduced classes, directly reflecting the imbalance caused by catastrophic forgetting, while the logit margin captures prediction certainty: forgotten or highly ambiguous samples exhibit smaller margins, confidently retained ones larger margins. Together, these statistics enable the grouping network to discover samples sharing similar calibration behavior, rather than simply partitioning samples into old and new classes.\n\nTo disentangle the contribution of each component, we perform three progressively stronger comparisons.\n\n|Method|Calibration / Routing|Feature Setting|ECE↓|AECE↓|Brier↓|\n|-|-|-|-|-|-|\n|PTS|Instance-wise TS|top-10 logits|9.87±0.77|10.14±0.67|0.596±0.008|\n|PTS|Instance-wise TS|CIL-aware features|6.88±0.91|6.87±0.91|0.575±0.008|\n|AdaTS|Instance-wise TS|penultimate feature|7.67±0.52|7.66±0.49|0.586±0.004|\n|AdaTS|Instance-wise TS|CIL-aware features|6.55±0.74|6.52±0.75|0.574±0.004|\n|**K-means Group-TS**|K-means (K=2) + group-wise TS|CIL-aware features|5.41±0.51|5.37±0.51|0.561±0.005|\n|**MT-CC**|Learned routing + group-wise TS|CIL-aware features|**4.49±0.53**|**4.44±0.49**|**0.556±0.006**|\n\nFirst, we evaluate **feature-matched** variants of PTS and AdaTS by providing them with exactly the same calibration statistics used by MT-CC. Both methods improve substantially, confirming that the proposed CIL-aware statistics themselves provide informative signals for calibration under continual distribution shifts.\n\nSecond, to directly address the reviewer's request for a grouped calibration baseline without our learned routing or optimization procedure, we introduce **K-means Group-TS (K=2)**. This baseline uses the same feature vector as MT-CC, but replaces the learned grouping network with unsupervised K-means clustering. A separate temperature is then optimized per cluster, and each test sample uses its nearest centroid's temperature. Importantly, this baseline uses **neither the learned grouping network nor GDCA**, providing a direct control for whether simply partitioning the same feature space into multiple temperature groups is sufficient.\n\nK-means Group-TS already improves substantially over the feature-matched PTS and AdaTS variants, showing that explicitly modeling heterogeneous calibration groups helps beyond generic instance-wise calibration. Nevertheless, MT-CC further reduces ECE from 5.41 to 4.49 and consistently achieves lower AECE and Brier score. Thus, neither access to the same CIL-aware statistics nor generic multi-group calibration alone fully explains the improvement.\n\nOverall, these comparisons highlight three contributions: **(1)** the CIL-aware calibration statistics themselves; **(2)** explicit modeling of heterogeneous calibration groups; and **(3)** MT-CC's learned calibration-aware grouping and optimization, which exploit these signals substantially more effectively than generic grouping or instance-wise calibration.\n\n# W2/Q2. Labeled Validation-Data Requirement\n\nThanks for the comment. First, **all methods compared in our paper are post-hoc temperature-scaling approaches, and therefore all of them require a labeled validation set $\\mathcal{D}^{val}$ for calibration.** Following the standard post-hoc calibration protocol, the data of each newly arrived task are split into a training set for model learning and a labeled $\\mathcal{D}^{val}$ for temperature estimation. MT-CC follows exactly the same protocol and **requires only the $\\mathcal{D}^{val}$ of the current task.** No labeled validation examples from previous tasks are retained.\n\nThis setting is evaluated in the **upper part of Table 1 and Table 3 (in the manuscript)**, where **MT-CC w/o augmentation** (i.e., using only the current task's $\\mathcal{D}^{val}$) consistently outperforms existing post-hoc calibration methods, including TS, ETS, IRM, PTS, and AdaTS, demonstrating that the proposed method remains effective when only the current task's $\\mathcal{D}^{val}$ is available.\n\nIn the **lower part of Table 1 and Table 3 (in the manuscript)**, we further investigate whether MT-CC can benefit from additional validation data. For this purpose, we adopt the validation-generation procedure of **T-CIL** [1], which converts the current task's $\\mathcal{D}^{val}$ and replay buffer into a generated validation set by perturbing labeled exemplars. This improves the validation coverage of previously learned classes **without introducing additional old-task validation memory**. Under exactly the same T-CIL-generated $\\mathcal{D}^{val}$, MT-CC consistently outperforms T-CIL and its variants, so the performance gain cannot be attributed to the validation-generation procedure itself, but rather to the proposed heterogeneous calibration mechanism.\n\nRegarding the implementation details, all baseline methods directly optimize their temperature parameter(s) using $\\mathcal{D}^{val}$. In contrast, MT-CC randomly splits $\\mathcal{D}^{val}$ into two disjoint subsets, $S_{\\mathrm{grp}}$ for training the grouping network and $S_{\\mathrm{cal}}$ for estimating the group-wise temperatures. When T-CIL augmentation is adopted, the T-CIL-generated validation set serves as $\\mathcal{D}^{val}$ following [1] before this random split. Accordingly, the **validation-size-zero** setting indicates that no T-CIL-generated samples are used, so $\\mathcal{D}^{val}$ consists solely of the labeled validation set of the current task.\n\nTherefore, T-CIL serves as an optional validation-generation strategy rather than a requirement of MT-CC. We will clarify these implementation details and the validation protocol in the revised manuscript.\n\n# W4/Q4. Robustness to ECE Binning and Brier Score\n\nWe conducted additional experiments on CIFAR-100 over 5 seeds, re-evaluating all methods with **10, 15, and 20 ECE bins** and the **Brier score**, while keeping the trained models, calibrated probabilities, and all other settings fixed.\n\n|Method|ECE@10↓|ECE@15↓|ECE@20↓|Brier↓|\n|-|-|-|-|-|\n|T-CIL|6.03±0.42|6.19±0.39|6.27±0.38|0.570±0.005|\n|T-CIL+ETS|5.63±0.52|5.80±0.45|5.87±0.44|0.571±0.004|\n|T-CIL+IRM|6.78±0.69|6.88±0.66|6.97±0.67|0.571±0.006|\n|T-CIL+AdaTS|7.67±0.52|7.76±0.50|7.86±0.51|0.586±0.004|\n|**MT-CC**|**4.49±0.53**|**4.62±0.51**|**4.72±0.54**|**0.556±0.006**|\n\nAcross all ECE bin configurations, MT-CC consistently achieves the lowest calibration error while preserving the same ranking among competing methods, demonstrating robustness to the choice of bin count. Furthermore, under the multi-class Brier score, MT-CC also achieves the best performance, confirming that its calibration improvements are not specific to ECE-based evaluation. We will include these new results in our revised manuscript.\n\n# W5/Q5. Scalability of the Grouping Network\n\nThank you for pointing this out. MT-CC follows the standard CIL setup, where the classifier output is defined over the full label space from the beginning and unseen classes are represented through zero-padding until they are introduced. Accordingly, the grouping network operates on a fixed-dimensional softmax vector throughout the task sequence and is re-trained after each task using the corresponding validation set, without requiring any architectural modification as new tasks arrive.\n\nIn Table 2 of our main manuscript, we have validated MT-CC on ImageNet with 1000 classes, one of the largest label spaces commonly considered in CIL evaluation. The results suggest that the current grouping-network design does not pose a practical bottleneck in existing CIL benchmarks. We will clarify these points in the revised manuscript.\n\n# W3/Q1. Correction of Overstated Claims\n\nWe agree that two statements are overly broad and will revise them to precisely match the reported results.\n\nFirst, in Sec. 5.1, we will revise \"MT-CC consistently achieves the lowest calibration errors ...\" to clarify that MT-CC achieves the lowest ECE and AECE across CIFAR-10, CIFAR-100, and Tiny-ImageNet, while remaining competitive in SCE. This accounts for the two SCE exceptions in Table 1 (CIFAR-100: 0.51 vs. 0.50; Tiny-ImageNet: 0.52 vs. 0.49).\n\nSecond, in Sec. 5.2, we will revise the statement that removing either grouping feature always increases ECE/AECE. The old/new confidence feature consistently improves calibration across all three datasets, whereas the logit-margin benefit is dataset-dependent: removing it slightly improves CIFAR-10 but degrades CIFAR-100 and Tiny-ImageNet.\n\n# W6. Limitations\n\nWe will expand the limitations section accordingly.\n\nRegarding the labeled calibration-data requirement and metric sensitivity, we refer the reviewer to our responses to **W2/Q2** and **W4/Q4**, respectively.\n\nRegarding the empirical and post-hoc nature of MT-CC, a theoretical understanding of why heterogeneous calibration behaviors emerge in CIL and how optimal calibration groups should be formed remains an interesting direction for future work. We will clarify this limitation in the revised manuscript.\n\n[1] T-CIL: Temperature scaling using adversarial perturbation for calibration in class-incremental learning, CVPR 2025."+ },+ "createdAt": "2026-07-26T14:58:02.872Z",+ "modifiedAt": "2026-11-18T17:18:12.907Z",+ "url": "https://openreview.net/forum?id=vCft9tPVmL¬eId=Zg3R79939Z",+ "license": "CC-BY-4.0"+}
reviews/openreview/vcft9tpvml/submission.json added
+++ b/reviews/openreview/vcft9tpvml/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "vCft9tPVmL",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 19918,+ "url": "https://openreview.net/forum?id=vCft9tPVmL",+ "license": "CC-BY-4.0"+}
versions/v_362hcqhd.json added
+++ b/versions/v_362hcqhd.json@@ -0,0 +1,22 @@+{+ "date": "2026-05-04",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (spotlight)",+ "number": 19918,+ "url": "https://openreview.net/forum?id=vCft9tPVmL",+ "reviews": "openreview/vcft9tpvml",+ "evidence": [+ "https://openreview.net/forum?id=vCft9tPVmL"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=vCft9tPVmL",+ "evidence": [+ "https://openreview.net/forum?id=vCft9tPVmL"+ ]+}