HoTS: Homophily-Aware Temperature Scaling for Graph Neural Network Calibration
Import NeurIPS 2026 submission woxrGUwgJ3: 8 notes
@openreview[bot] · 2026-11-22 18:00 UTC · ee682cbc7aab ·
reviews/openreview/woxrguwgj3/forms.json added
+++ b/reviews/openreview/woxrguwgj3/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/woxrguwgj3/notes/2zgp7axzpd.json added
+++ b/reviews/openreview/woxrguwgj3/notes/2zgp7axzpd.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "2zgP7axzPd",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "The paper studies calibration of GNN predictions using local homophily and proposes an interpretable method with broad empirical evaluation. The reviewers find its strengths in the theoretical motivation, lightweight calibration rule, extensive datasets, and detailed ablations.\n\nThe primary issue is possible test-label leakage when constructing homophily targets for training and validation nodes whose neighbors include test nodes. The authors must clarify which labels are used and provide leakage-free results if test-neighbor labels were accessed. They should also clarify the modest improvement over entropy-only scaling, the additional cost of the auxiliary predictor, and the gap between the positive-signal theory and the implemented rule in low-homophily regimes. A convincing resolution of the leakage concern, together with evidence that the homophily component will argue the merit of this paper.",+ "final_justification": "The rebuttal substantially addresses the critical test-label leakage issue through corrected leakage-free experiments, and the reviewers generally found that the main technical concerns were resolved or appropriately scoped. The remaining limitation is that the additional benefit from the homophily component over entropy-based scaling is modest, but the corrected results still support the main calibration claim across datasets and backbones. Overall, I recommend acceptance."+ },+ "createdAt": "2026-09-24T11:23:08.448Z",+ "modifiedAt": "2026-11-18T14:56:38.451Z",+ "url": "https://openreview.net/forum?id=woxrGUwgJ3¬eId=2zgP7axzPd",+ "license": "CC-BY-4.0"+}
reviews/openreview/woxrguwgj3/notes/ajrfcx2lc4.json added
+++ b/reviews/openreview/woxrguwgj3/notes/ajrfcx2lc4.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "ajrFcx2Lc4",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer DeuQ",+ "content": {+ "summary": "This work addresses a challenge of calibrating node-classification probabilities produced by graph neural networks when the reliability of a prediction depends not only on its logits but also on its local graph structure. The paper proposes that a single global temperature, or even a calibrator based only on logits, can be insufficient because nodes with similar logits may have different probabilities of being correct when their neighborhoods have different levels of homophily.\n\nThis paper analyzes a population-concentration Contextual Stochastic Block Model (CSBM) with Gaussian node features and a one-layer linear GCN with self-loops. Based on the results, the paper proposes proposes Homophily-Aware Temperature Scaling (HoTS), which assigns each node a positive temperature using an entropy-based logit-concentration term, an estimated local-homophily term, and three learned scalar parameters.\n\nThe empirical evaluation covers 18 node-classification datasets, GCN and GAT backbones, and several standard and graph-aware calibration baselines. The paper reports that HoTS obtains the best macro-averaged ECE, average rank, mean NLL, degree-stratified ECE, and selective-classification performance among the compared methods.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "### Strengths\n\n1. The method is interpretable. HoTS uses only three learned scalar parameters after estimating local homophily. Unlike high-capacity auxiliary calibration networks, the proposed temperature formula has an interpretable dependence on logit concentration and local structure, and it preserves the original predicted class.\n\n2. The experimental evaluation is broad. The paper includes 18 datasets, two backbones, ten seeds, multiple calibration baselines, NLL and degree-stratified ECE in addition to ordinary ECE, selective classification, component ablations, perturbation experiments, and controlled CSBM simulations.\n\n3. Appendix B.7 to B.8 provide informative ablation experiments. The entropy-only, homophily-only, fixed-exponent, fixed-shuffling, and per-training-step shuffling controls help separate the effects of entropy and estimated homophily.\n\n### Weakness\n\n1. My main concern is the test-label leakage in the homophily-predictor supervision. Appendix C.5 states that although predictor supervision is restricted to known sets: training and validation center nodes, the sum ranges over all neighbors. My intepratation is, for a training or validation node adjacent to a test node, constructing $h_i^{gt} = 1/(max(d_i, 1)) \\sum_{j \\in N(i)} 1 \\{(y_j = y_i )}$ appears to use that test node's ground truth label. \n - Consider this simple graph: Node A: training node, true label = class 1; Neighbor B: test node, true label = class 1; Neighbor C: test node, true label = class 2. Then the computing this $h_A^{gt} = (1 (y_B = y_A) + 1 (y_C = y_A))/2 = (1 + 0) / 2 = 0.5$. Computing this value requires knowing both $y_B$ and $y_C,$ even though B and C are test nodes. The test labels therefore indirectly enter the training of the auxiliary GCN.\n - This seems to contradict the statement that “no test-label information enters the calibration pipeline.” Restricting the set of supervised center nodes to train and validation nodes does not prevent leakage if the target for those nodes is itself calculated using test-neighbor labels. This issue is particularly consequential because the homophily predictor is a central input to HoTS. The paper needs to clarify exactly which neighbor labels are used when constructing each target.\n\n2. The empirical gain from the specifically homophily-dependent component is modest. In the component ablation in Appendix B.7, entropy-only scaling achieves a mean ECE of 4.83%, compared with 6.04% for TS and 4.66% for full HoTS. Thus, the additional improvement from incorporating estimated homophily is 0.17 percentage points in mean ECE, whereas entropy-dependent node-wise scaling accounts for most of the total improvement over TS.\n\n3. As stated in Appendix C.1, Table 11, all datasets, including ogbn-arxiv, use fresh random 20/10/70 splits rather than official splits. The official ogbn-arxiv split is time-based, training on earlier papers and evaluating on later papers, and therefore provides a natural benchmark for temporal distribution shift. Since confidence calibration can degrade under distribution shift, evaluating HoTS on this split would provide evidence about temporal calibration that is absent from the current random-split protocol. \n\n4. The paper uses ECE as its primary metric and specifies 15 equally spaced confidence bins, but it does not explicitly define ECE or provide its formula. Since ECE can vary with binning and implementation details, a formal definition would improve clarity and reproducibility.\n\n5. HoTS achieves the best aggregate mean ECE and average rank, but its performance varies considerably across individual datasets. HoTS’s aggregate advantage is not uniform across datasets. In Table 1, HoTS ranks 7th of 9 calibration methods on CoraFull, with an ECE of 3.73% compared with 2.20% for the best method, ETS. It ranks last, 9th of 9, on Roman-Empire, with 4.45% ECE compared with 2.10% for VS. HoTS also ranks 8th of 9 on PubMed, with 1.18% ECE compared with 0.83% for WATS, and 4th among the 8 reported methods on Reddit, with 1.26% ECE compared with 0.94% for CaGCN. \nThe selective-classification improvements (Table 2) are also small: compared with TS, HoTS improves retained accuracy by only 0.04 percentage points at 95% coverage and 0.28 percentage points at 70% coverage.",+ "quality": 2,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "1. Regarding weakness 1, when computing $h_i^{gt}$ for a training or validation node, are ground-truth labels of neighboring test nodes used? If not, please describe the masking procedure precisely. If they are used, please provide additional leakage-free experiemntal results in which test-neighbor labels are unavailable.\n\n2. As a follow up to question 1, do the graph-aware baselines also receive information derived from test labels, or is this target construction unique to HoTS? Please specify the exact label information available to every calibration method.\n\n3. Can the authors report the accuracy or correlation of the homophily predictor itself, separately for training, validation, and test nodes? This would clarify how much information about oracle homophily is recoverable without test labels.\n\n4. Can the authors provide the formal definition and exact implementation of ECE used in the experiments? The paper specifies 15 equally spaced confidence bins but does not appear to give the equation or details such as bin weighting, treatment of empty bins, and aggregation across seeds and backbones. Because ECE is sensitive to these choices, this clarification would improve reproducibility.\n\n5. Can the authors report results using the official ogbn-arxiv chronological split, or another clearly defined distribution-shift setting? Since all current experiments use random splits, the evaluation does not establish whether HoTS improves calibration when the graph distribution changes over time.",+ "limitations": "The current limitations discussion is relatively good, but it should additionally mention:\n- the dependence on accurately estimating local homophily without access to test labels;\n- the small incremental improvement over entropy-only node-wise temperature scaling;\n- the lack of evaluation under official temporal or distribution-shift splits; the fact that random-split transductive benchmarks may not reflect deployment settings in which node labels and graph structure arrive over time;",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The rebuttal substantially addresses my main concern. The authors acknowledged the test-label leakage in the submitted implementation, introduced an observed-label-only correction, and provided corrected GCN+GAT results with per-dataset ECE. The corrected HoTS-NoLeak result still achieves the best mean ECE and mean rank, so the central aggregate calibration claim appears to hold without test-label access. I also appreciate the corrected entropy-only comparison and the authors’ commitment to soften claims about heterophilic gains and selective classification. \n\nMy remaining concern is that the incremental gain of the homophily component over entropy-only scaling is very small under the corrected protocol, and the selective-classification gains are also small. \n\nOverall, the rebuttal moves my assessment from borderline reject to borderline accept."+ },+ "createdAt": "2026-06-29T06:31:16.863Z",+ "modifiedAt": "2026-11-18T13:41:30.368Z",+ "url": "https://openreview.net/forum?id=woxrGUwgJ3¬eId=ajrFcx2Lc4",+ "license": "CC-BY-4.0"+}
reviews/openreview/woxrguwgj3/notes/f2kietiqfa.json added
+++ b/reviews/openreview/woxrguwgj3/notes/f2kietiqfa.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "f2KIETiQfa",+ "replyTo": "woR4HUVRfn",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We thank the reviewer for recognizing the novelty of the CSBM perspective and for posing focused questions. The common leakage correction and leakage-free aggregate are reported in our response to Reviewer DeuQ; below we answer Q1–Q5 directly.\n\n---\n\n### Q1: why focus on homophily?\nWe do **not** claim that homophily is universally more important than every graph statistic. Our claim is narrower: it is a theoretically tractable first-order structural variable that also contains reliability information not already present in confidence or degree.\n\nIn the CSBM, local homophily directly controls class-signal strength after message passing and therefore yields an explicit Bayes temperature law. Motifs, curvature, centrality, and higher-order statistics may also matter, but do not yield the same transparent one-dimensional mechanism in our analysis.\n\nThe relevance is also visible beyond the CSBM. Across approximately four million held-out predictions, conditioning on confidence and splitting by homophily produces high- versus low-homophily accuracy gaps of **3.9–32.9 pp**; in **6/7 bins**, the groups require corrections in opposite directions. After residualizing correctness and normalized homophily against confidence and log-degree,\n\n$$r(\\tilde h,\\mathrm{correct}\\mid\\mathrm{confidence},\\log d)=0.384$$\n\n(0.283 under dataset-level macro averaging), while the raw log-degree/correctness correlation is 0.014. Thus, homophily is not merely a degree proxy. We will frame it as an interpretable and independently informative axis, not the only possible structural axis.\n\n### Q2: formal definition of $h$\nFor node $i$, with $\\mathcal N(i)$ excluding the self-loop,\n\n$h_i=\\frac{1}{|\\mathcal N(i)|}\\sum_{j\\in\\mathcal N(i)}\\mathbf1[y_j=y_i]\\in[0,1], \\quad \\tilde h_i=\\frac{Kh_i-1}{K-1}\\in[-\\frac{1}{K-1},1]$.\n\nHere, $\\tilde h_i=0$ is the class-random baseline $h_i=1/K$, $\\tilde h_i>0$ denotes above-random same-class support, and $\\tilde h_i<0$ below-random support. We will distinguish the random variable $H_i$, its realization/oracle $h_i$ used only in theory and diagnostics, and the estimated $\\hat h_i$ used by HoTS. The leakage-free estimator is defined in our response to Reviewer DeuQ.\n\n### Q3: what extends beyond the simplified theory?\n\nTwo levels of the result should be separated\n\n1. **The necessity proposition is architecture-agnostic.** Whenever the CE-optimal temperature varies with homophily after conditioning on logits, any logit-only calibrator is strictly suboptimal. This statement does not require a CSBM or a GCN.\n2. **The closed-form inverse-homophily law is CSBM-specific.** The one-layer linear GCN provides a tractable setting in which the proposition’s condition can be verified and the sign/scale of the structural effect derived. We do not claim that this exact posterior remains valid for arbitrary nonlinear, multi-layer models.\n\nHoTS uses the CSBM result as a structural prior rather than copying the exact Bayes rule. It operates post hoc on frozen logits and learns $T_{\\mathrm{base}},\\beta,\\alpha$ from calibration data, allowing the fitted map to absorb architecture and estimation mismatch. Whether this prior transfers to more complex backbones is therefore an empirical question, addressed below.\n\n### Q4: stronger and heterophily-oriented backbones\nWe added GCNII (residual/identity mapping), GPR-GNN (learned generalized PageRank and heterophily-oriented propagation), GIN, and GraphSAGE. The table reports macro ECE (%) over the same 17 datasets and 10 seeds; Reddit is excluded because some all-method pipelines exceed memory. Original GCN/GAT results are included as reference.\n\n| Backbone | TS | VS | ETS | HTS | CaGCN | GATS | GETS | WATS | **HoTS** |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| GCN | 6.90 | 6.55 | 6.46 | 6.05 | 6.17 | 6.52 | 7.17 | 7.75 | **4.84** |\n| GAT | 5.69 | 5.41 | 5.23 | 5.19 | 5.22 | 5.04 | 6.03 | 7.16 | **4.87** |\n| GCNII | 6.83 | 6.08 | 6.33 | 6.22 | **5.75** | 6.36 | 6.70 | 7.75 | 6.03 |\n| GPR-GNN | 6.84 | 5.95 | 6.47 | 5.72 | 6.05 | 5.87 | 7.15 | 7.77 | **5.26** |\n| GIN | 6.31 | 5.66 | 5.40 | 5.23 | 6.37 | 5.31 | 6.34 | 8.94 | **4.82** |\n| GraphSAGE | 6.59 | 6.10 | 5.49 | 5.75 | 6.63 | 5.77 | 6.35 | 9.20 | **5.10** |\n\nHoTS is first on five of six backbones and second on GCNII; its mean backbone rank is **1.17**, versus 2.67 for HTS, 3.83 for GATS, and 4.83 for CaGCN. CaGCN is first on GCNII but drops to eighth on GIN and GraphSAGE, whereas HoTS remains top-2 throughout. These results support empirical architecture transfer without claiming that the CSBM theorem becomes exact for these models.\n\n### Q5: practical robustness across datasets\nWe agree that no practitioner should choose HoTS because it wins every dataset—it does not. We will explicitly acknowledge CoraFull, PubMed, and Roman-Empire. The practical case is a stable aggregate profile:\n\n- pooled GCN+GAT mean ECE **4.66%** and average rank **3.22**, both best\n- top-3 placement on 11/18 datasets\n- after removing Texas and Cornell, HoTS remains first (3.50% vs 3.81% HTS and 3.84% CaGCN)\n- leakage-free GCN macro ECE remains first (5.08% vs 5.78% HTS and 5.90% CaGCN)\n- top-2 performance across every backbone reported above.\n\nAccordingly, our recommendation will be conditional rather than absolute. On a known, structurally uniform homophilic graph with strict compute constraints, entropy-only/HTS may be sufficient. When local structural reliability or the backbone is heterogeneous or unknown, HoTS offers the strongest aggregate and cross-backbone rank profile while preserving the base predicted class. Exact overhead is reported in our response to Reviewer E8XP.\n\n---\nWe sincerely thank the reviewer for their interest in our work. We would be happy to address any further questions or remaining concerns !"+ },+ "createdAt": "2026-07-27T13:21:29.318Z",+ "modifiedAt": "2026-11-18T17:18:24.849Z",+ "url": "https://openreview.net/forum?id=woxrGUwgJ3¬eId=f2KIETiQfa",+ "license": "CC-BY-4.0"+}
reviews/openreview/woxrguwgj3/notes/kkxfbsrakn.json added
+++ b/reviews/openreview/woxrguwgj3/notes/kkxfbsrakn.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "KkxFBsRakN",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer E8XP",+ "content": {+ "summary": "The paper proposes HoTS, a post-hoc calibration method for GNN node classification based on node-wise softmax temperature scaling. The main idea is that a node's local homophily should affect its calibration temperature, and the authors instantiate this idea with a simple three-parameter homophily-aware temperature scaling method. The paper provides theoretical motivation under a contextual stochastic block model, together with controlled ablations to support the proposed relationship. Experiments on several types of graph-structured datasets show improved average calibration performance over existing baselines.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "**Strength**:\n- Unlike many methods that rely on black-box architectures to learn an instance-dependent temperature, this work is motivated by a first-principles derived phenomenon under a CSBM and formally establishes the inverse relation between calibration temperature and local homophily.\n- The experiments are extensive and provide comprehensive comparison for the reader to understand the context. \n\n**Weakness**:\n\n- While HoTS achieves the lowest average ECE, this arithmetic mean appears sensitive to substantial drops from a few heterophilic datasets with very high uncalibrated baselines, such as Texas and Cornell. Though the authors claim the improvements are significant in text, the actual comparison does not show that, particularly on homophilic datasets.\n- Although the paper emphasizes HoTS to be a three-parameter method to imply its lightweightness, the full pipeline also requires training an auxiliary GCN to estimate local homophily. Describing it simply as a “three-parameter calibrator” may understate the complexity and computation overhead.\n- The derivation based on CSBM is neat but relies on strong assumptions and is formally restricted to the \"positive-signal regime\". The implemented HoTS applies a heuristic absolute-value extension in Eq. 8 to force a positive temperature for negative signal cases. Fig. 1(a) does not show the low-homophily region near $h=0$. This is precisely where the signed Bayes inverse-temperature may become zero or negative, while Eq. 8 still enforces a positive temperature through the absolute-value heuristic. The paper does not sufficiently address this gap between the theory and the implemented rule.",+ "quality": 3,+ "clarity": 3,+ "significance": 2,+ "originality": 3,+ "questions": "- Given the marginal improvements on homophilic benchmarks, compared to vanilla TS, how do the authors justify the added pipeline complexity of having to train a separate GCN? Could the authors report the computational overhead of HoTS?\n- Line 274-275: Could you discuss the fraction of nodes whose estimated normalized homophily falls into the negative/near-zero regime on examples from both homophilic and heterophilic datasets? And how does that affect the final performance?\n- Fig. 1(a) shows T vs. h on interval (0.2 to 1.0) and the variance tends to be larger as h becomes smaller. What is the empirical behavior on (0.0,0.2)?",+ "limitations": "N/A",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "NA",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The rebuttal addresses my main concerns with targeted analyses and clearer claims. The aggregate improvement remains after removing the two datasets with the largest gains, the auxiliary GCN introduces a modest one-time overhead, and the boundary between the theory and the implemented extension is now clearly stated. The gains on homophilic datasets remain limited and the negative-signal extension is still heuristic, but the strengths now slightly outweigh these limitations. I therefore raise my rating to 4."+ },+ "createdAt": "2026-06-20T22:51:16.691Z",+ "modifiedAt": "2026-11-18T13:41:32.227Z",+ "url": "https://openreview.net/forum?id=woxrGUwgJ3¬eId=KkxFBsRakN",+ "license": "CC-BY-4.0"+}
reviews/openreview/woxrguwgj3/notes/oiqkwl9ngc.json added
+++ b/reviews/openreview/woxrguwgj3/notes/oiqkwl9ngc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "oIQKWl9nGc",+ "replyTo": "ajrFcx2Lc4",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "## Response to Reviewer DeuQ\n\nWe thank the reviewer for the careful reading and for recognizing the interpretability and breadth of our study. The review also identified a genuine implementation error. We address it directly and report the corrected evidence below.\n\n### Q1–Q3: test-label leakage, masking, label access, and predictor quality\n\nIn the submitted implementation, supervised center nodes were restricted to train/validation nodes, but their targets were aggregated over all neighbors. Hence, a test neighbor’s ground-truth label could enter the auxiliary target. We withdraw the statement that “no test-label information enters the calibration pipeline” and replace the submitted construction with the following observed-label-only target.\n\nLet $\\mathcal I_L=\\mathcal I_{\\mathrm{tr}}\\cup\\mathcal I_{\\mathrm{val}},\\qquad \\mathcal N_L(i)=\\{j\\in\\mathcal N(i):j\\neq i,\\ j\\in\\mathcal I_L\\}$, $h_i^{\\mathrm{mask}} =\\frac{1}{|\\mathcal N_L(i)|}\\sum_{j\\in\\mathcal N_L(i)} \\mathbf 1[y_j=y_i],\\qquad \\mathcal M=\\{i\\in\\mathcal I_L:|\\mathcal N_L(i)|>0\\}. $\n\nThe homophily predictor is trained only on valid observed-label centers: $\\mathcal L_{\\mathrm{hom}} =\\frac{1}{|\\mathcal M|}\\sum_{i\\in\\mathcal M} (\\hat h_i-h_i^{\\mathrm{mask}})^2$.\n\nThus, test nodes are neither supervised centers nor labeled neighbors, and self-loops are excluded from target construction. The revised method may use the full adjacency and node features transductively, but **no test label enters either the predictor target or the temperature-map fitting**.\n\n**Table Leakage correction and test-label permutation audit (GCN, 18 datasets).**\n**Panel A. Leakage-free calibration performance.** \n*Mean ECE over 10 seeds. Lower is better.*\n| Method | Mean ECE (%) |\n|---|---:|\n| Submitted HoTS† | 4.64 |\n| **HoTS-NoLeak** | **5.08** |\n| HTS | 5.78 |\n| CaGCN | 5.90 |\n\n† The submitted construction is reported only to quantify the effect of the correction. It used test-neighbor labels in some auxiliary targets.\n\n**Panel B. Test-label permutation audit.** \n*Mean absolute ECE change after permuting test labels over 5 seeds. Lower is better.*\n| Pipeline | All datasets | Heterophilic subset |\n|---|---:|---:|\n| **HoTS-NoLeak** | **0.041 pp** | **0.082 pp** |\n| Submitted HoTS | 0.556 pp | 0.992 pp |\n\nPanel A shows that removing all test-neighbor labels increases mean ECE from 4.64% to 5.08%, corresponding to a **0.44 pp correction cost** that we do not minimize. Crucially, the fully leakage-free HoTS still outperforms the strongest baseline, HTS, by **0.70 pp**, and CaGCN by **0.82 pp**.\n\nPanel B reports a separate diagnostic rather than calibration performance itself. It measures how much the fitted pipeline changes when test labels are permuted. The masked pipeline changes by only **0.041 pp** overall and **0.082 pp** on heterophilic datasets, compared with **0.556 pp** and **0.992 pp**, respectively, for the submitted construction. The explicit mask provides the formal guarantee that test labels are unavailable, while the permutation audit serves as an empirical sanity check consistent with that guarantee.\n\nThe exact post-hoc label access is:\n\n| Method | Calibration inputs | Calibration labels | Test labels |\n|---|---|---|---|\n| TS/ETS/HTS/VS | frozen logits | validation | none |\n| CaGCN/GATS/GETS/WATS | frozen outputs/features and transductive graph | validation | none |\n| HoTS estimator | features and transductive graph | observed train/validation labels through $h_i^{\\mathrm{mask}}$ | none |\n| HoTS temperature map | frozen logits and $\\hat h_i$ | validation | none |\n\nThe problematic neighbor-label target was unique to the submitted HoTS implementation. All corrected methods have equal access with respect to held-out information: **none uses test labels**, although their permitted train/validation supervision differs as reported above.\n\nBecause homophily is continuous, we report MAE and Pearson correlation rather than classification accuracy:\n| Split | MAE | Pearson $r$ | observed-neighbor coverage |\n|---|---:|---:|---:|\n| Train | 0.234 | 0.422 | 64.5% |\n| Validation | 0.231 | 0.453 | 64.6% |\n| Test | 0.260 | 0.206 | 64.5% |\n\nTest oracle homophily is used **only for this diagnostic**, never for training or temperature construction. Recovery is deliberately partial; on heterophilic graphs, only 47.7% of test nodes have an observed labeled neighbor and the median count is 1.4. HoTS therefore treats $\\hat h_i$ as a regularized structural covariate, with learned $\\alpha$ controlling its influence.\n\n### Homophily beyond entropy-only scaling\nWe agree that entropy explains most of the *pooled average* gain and will avoid implying that the homophily term is uniformly large. However, the 0.17 pp aggregate increment mixes regimes where local homophily is nearly uniform with regimes where it is decisive.\n\nAcross approximately four million held-out predictions, we conditioned on base confidence and split each bin by local homophily. High- versus low-homophily accuracy differs by **3.9–32.9 pp**; in **6/7 bins**, the two groups require corrections in opposite directions. A logit-only calibrator maps equal-confidence/logit nodes identically and cannot correct both groups simultaneously. This is the empirical condition behind Proposition 1.\n\nThe component gain is accordingly regime-dependent: adding homophily to entropy-only changes ECE by approximately 0 pp on homophilic datasets, but reduces it by **0.63 pp on average on heterophilic datasets** (Texas +2.33, tolokers +0.97, Cornell +0.87, Wisconsin +0.80, Squirrel +0.51). Full HoTS beats entropy-only on 13/18 datasets (paired Wilcoxon $p<0.05$). Our revised claim is therefore that entropy supplies the general node-wise correction, while homophily supplies residual information where the same confidence has different structural meaning.\n\n### Q4: exact ECE definition and binning sensitivity\nFor test node $i$, let $c_i=\\max_k p_i(k)$, $\\hat y_i=\\arg\\max_kp_i(k)$, and $a_i=\\mathbf1[\\hat y_i=y_i]$. With $M=15$, $B_m=\\{i:\\frac{m-1}{M}<c_i\\le\\frac mM\\},\\quad \\mathrm{ECE}=\\sum_{m=1}^{M}\\frac{|B_m|}{N} |\\mathrm{acc}(B_m)-\\mathrm{conf}(B_m)|$.\n\nThis is top-label, equal-width, count-weighted ECE. Empty bins contribute zero; ECE is evaluated only on test nodes and reported in percent. For each dataset/backbone, we report mean±standard deviation over 10 seeds. The pooled table combines the 10 GCN and 10 GAT runs per dataset and then macro-averages dataset means.\n\nAs a binning-only check on the stored submitted predictions, HoTS remains first for equal-width $M\\in\\{5,10,15,20,25,30\\}$ and 15 equal-mass bins. Representative HoTS versus HTS values are 3.95 vs 4.74 (equal-width 5), 4.64 vs 5.79 (equal-width 15), 5.47 vs 6.43 (equal-width 30), and 5.72 vs 6.48 (15 equal-mass).\n\n### Q5: official ogbn-arxiv chronological split\nUsing the same masked construction on the official time split—papers through 2017 for training, 2018 for validation, and 2019+ for testing (90,941/29,799/48,603 nodes)—GCN with 10 seeds gives:\n\n| Method | ECE (%) |\n|---|---:|\n| **HoTS-NoLeak** | **1.68 ± 0.60** |\n| HTS | 2.31 ± 1.00 |\n| CaGCN | 2.73 ± 0.80 |\n| GATS | 2.95 ± 1.30 |\n| TS | 3.72 ± 0.70 |\n\nHoTS remains first and leads the runner-up by 0.63 pp. Absolute ECE increases relative to the random split, as anticipated, while the relative margin grows. This is evidence under one natural temporal shift, not a claim of universal distribution-shift robustness; we will state that limitation explicitly.\n\n### Robustness across datasets and backbones\n\nIn the full pooled GCN+GAT evaluation, HoTS achieves the best mean ECE (**4.66%**) and mean rank (**3.22**), with top-3 performance on **11/18 datasets**. We further examine whether this advantage persists after removing the two high-ECE datasets, correcting the leakage issue, and changing the backbone architecture.\n\n**Robustness under dataset and backbone variation.**\n**Panel A. Dataset-level stress tests.** \n| Evaluation | **HoTS** | HTS | CaGCN |\n|---|---:|---:|---:|\n| Excluding Texas and Cornell | **3.50** | 3.81 | 3.84 |\n| Leakage-free GCN, 18 datasets | **5.08** | 5.78 | 5.90 |\n\n**Panel B. Cross-backbone stability.**\n| Evaluation | Top-2 | First | Mean rank |\n|---|---:|---:|---:|\n| Six backbones (GCN, GAT + four added) | **6/6** | **5/6** | **1.17** |\n\nPanel A shows that the aggregate advantage remains after excluding Texas and Cornell and after removing all test-neighbor labels. In particular, HoTS-NoLeak retains a **0.70 pp** lead over HTS. Panel B shows that HoTS remains top-2 across all six backbones—GCN, GAT, GCNII, GPR-GNN, GIN, and GraphSAGE—first on five and second only on GCNII (mean rank 1.17), indicating that its robustness is not specific to the original GCN and GAT backbones.\n\n---\nThank you again for your interest in our work. We would be happy to address any further questions, comments, or concerns."+ },+ "createdAt": "2026-07-27T12:49:30.939Z",+ "modifiedAt": "2026-11-18T17:18:24.695Z",+ "url": "https://openreview.net/forum?id=woxrGUwgJ3¬eId=oIQKWl9nGc",+ "license": "CC-BY-4.0"+}
reviews/openreview/woxrguwgj3/notes/udhle8r4zc.json added
+++ b/reviews/openreview/woxrguwgj3/notes/udhle8r4zc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "UdhLE8R4Zc",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair 93Tb",+ "content": {+ "metareview": "The paper studies calibration of GNN predictions using local homophily and proposes an interpretable method with broad empirical evaluation. The reviewers find its strengths in the theoretical motivation, lightweight calibration rule, extensive datasets, and detailed ablations.\n\nThe primary issue is possible test-label leakage when constructing homophily targets for training and validation nodes whose neighbors include test nodes. The authors must clarify which labels are used and provide leakage-free results if test-neighbor labels were accessed. They should also clarify the modest improvement over entropy-only scaling, the additional cost of the auxiliary predictor, and the gap between the positive-signal theory and the implemented rule in low-homophily regimes. A convincing resolution of the leakage concern, together with evidence that the homophily component will argue the merit of this paper."+ },+ "createdAt": "2026-07-21T06:55:28.388Z",+ "modifiedAt": "2026-11-18T15:22:56.854Z",+ "url": "https://openreview.net/forum?id=woxrGUwgJ3¬eId=UdhLE8R4Zc",+ "license": "CC-BY-4.0"+}
reviews/openreview/woxrguwgj3/notes/wor4huvrfn.json added
+++ b/reviews/openreview/woxrguwgj3/notes/wor4huvrfn.json@@ -0,0 +1,31 @@+{+ "schema": "review/1",+ "id": "woR4HUVRfn",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer 1i4a",+ "content": {+ "summary": "Existing methods on GNN calibration have showed that graph structure matters when determining the temperature scaler or logit transformation, but did not specify the form of structural correction. This work studies how the optimal node-wise temperature should depend on local global structure, especially homophily. Then, it proposes Homophily-aware Temperature Scaling (HoTS) that uses a global offset, a correction scale, and a homophily-sensitivity exponent to assign each node a temperature scaler.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "**Strength**\n\n-\t**[S1.Quality]** The proposed method is clearly explained and verified with various datasets.\n\n-\t**[S2.Clarity]**: Overall clarity is ok.\n\n-\t**[S3.Significance]**: The proposed method partially addresses the lack of theoretical support for the importance of graph structure in GNN calibration.\n\n-\t**[S4 .Originality]**: The proposed method is novel, and the CSBM-based analysis provides a new theoretical perspective for studying calibration in GNNs.\n\n**Weakness**\n\n-\t**[W1 -> Q1: Lack of motivation to consider homophily only]** No clear evidence on why only homophily is considered while other graph patterns are not mentioned. \n\n-\t**[W2-> Q2: Missing definition of math notation]** Line 147, $h$ is not formally defined.\n\n-\t**[W3 -> Q3 and Q4: Lack of extension to advanced GNNs]** The theory is developed under a simplified setting: a uniform-prior CSBM with Gaussian node features and a one-layer linear GCN with self-loops. How well do the theoretical conclusions extend to more complex GNN architectures? Since the experiments only use basic GCN and GAT backbones, it would be helpful to evaluate the method on stronger architectures, particularly models designed for heterophilic graphs.\n\n-\t**[W4 -> Q5: Experiment results lack of robust advantage]** Although HoTS achieves the best average ECE, its per-dataset performance is inconsistent, and its advantage over competing methods is not stable across datasets. This weakens the practical justification for choosing HoTS over more robust alternatives.",+ "quality": 2,+ "clarity": 3,+ "significance": 2,+ "originality": 3,+ "questions": "**[Explanation of Questions]** The authors are only expected to answer the following questions. No need to prepare responses for weakness. The score could potentially be increased if the major concerns are adequately addressed. \n\n**[Q1: Why focusing on homophily?]** While local graph structures are important to GNN calibration, why this work specifically focuses on the homophily pattern? Is there any evidence to show that homophily is more critical in this task than other graph structural patterns?\n\n**[Q2: Missing definition of math notation]** Line 147, what is $h$? It is not formally defined.\n\n**[Q3: Theoretical assumption]** As stated in the paper, “the theory is developed under a uniform-prior CSBM with Gaussian node features and a one-layer linear GCN with self-loops.” How can the conclusions derived under this simplified setting be extended to scenarios involving more complex model structures?\n\n**[Q4: Selection of backbone models]** Following Q3, the backbone models used in experiments are GCN and GAT, which are very fundamental architectures. Since the method is developed for node classification task, it should be necessary to consider more complex architectures, especially those designed for heterophilic graphs. \n\n**[Q5: Experiment results lack of robust advantage]** The proposed method achieves the best average ECE, but its per-dataset performance appears unstable and the advantage over competing methods is not consistently observed across datasets. From a practical deployment perspective, how should practitioners justify choosing HoTS over methods with more stable per-dataset behavior?",+ "limitations": "Yes.",+ "rating": 3,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes"+ },+ "createdAt": "2026-06-13T06:42:39.556Z",+ "modifiedAt": "2026-11-18T13:41:34.004Z",+ "url": "https://openreview.net/forum?id=woxrGUwgJ3¬eId=woR4HUVRfn",+ "license": "CC-BY-4.0"+}
reviews/openreview/woxrguwgj3/notes/x4p8smtqmg.json added
+++ b/reviews/openreview/woxrguwgj3/notes/x4p8smtqmg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "X4p8sMtQMg",+ "replyTo": "KkxFBsRakN",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We thank the reviewer for highlighting both the first-principles motivation and the extensive evaluation. We agree that the paper should distinguish more carefully between aggregate robustness, the cost of the full pipeline, and the boundary between the positive-signal theorem and the implemented absolute-value rule.\n\n---\n\n### Aggregate performance is not explained by Texas/Cornell alone\nHoTS is not uniformly best, and we will avoid implying otherwise. However, its aggregate result is not explained by two high-ECE datasets. In the pooled GCN+GAT table, HoTS has both the lowest macro ECE (4.66%) and best mean rank (3.22), with top-3 placement on 11/18 datasets. Removing both Texas and Cornell still leaves HoTS first: **3.50% mean ECE**, versus **3.81% HTS** and **3.84% CaGCN**. Thus, the conclusion is robust both to a magnitude-insensitive rank statistic and to the reviewer’s proposed leave-two-out counterfactual.\n\nThe effect is regime-dependent. On the eight homophilic datasets, HoTS is essentially tied with the best method (1.944% vs 1.941% ETS), whereas on the eight heterophilic datasets it gives the clear gain (8.19% vs 9.56% CaGCN). Consistently, the homophily term adds approximately 0 pp over entropy-only on homophilic datasets but reduces ECE by **0.63 pp on average** on heterophilic datasets. We will therefore replace any universal-superiority wording with the narrower claim that structural correction is most useful when local reliability varies with graph regime.\n\n### Q1: full-pipeline complexity and computational overhead\nThe reviewer is correct that “three-parameter method” can be read as describing the entire pipeline. We will replace it with:\n\n> **HoTS uses a three-scalar temperature map $(T_{\\mathrm{base}},\\beta,\\alpha)$ together with a separately trained two-layer GCN homophily estimator.**\n\n| Dataset | TS / Entropy-only / HoTS fit (s) | HoTS inference (ms) | HoTS peak memory (MB) |\n|---|---:|---:|---:|\n| Cora | 0.65 / 2.26 / **4.46** | 0.48 | 26.2 |\n| Computers | 0.09 / 3.13 / **4.46** | 0.47 | 50.5 |\n| ogbn-arxiv | 0.14 / 2.41 / **3.30** | 0.21 | 176.8 |\n\nRelative to entropy-only scaling, the estimator adds 0.9–2.2 s. It is fitted once and $\\hat h$ is cached, so calibrated inference remains sub-millisecond; the auxiliary GCN is not rerun per query. On a known, uniformly homophilic graph, entropy-only/HTS may be a reasonable cheaper choice. When the structural regime is heterogeneous or unknown, the one-time estimator cost buys a signal unavailable to a logit-only rule and requires no retraining of the base classifier.\n\n### Q2–Q3: positive-signal theory, negative regimes, and the omitted low-homophily range\nWe agree with the central distinction: the exact Bayes-temperature result is proved only for $\\Gamma(h)=\\rho_0\\frac{1+\\bar d\\,\\tilde h}{\\bar d+1}>0, \\quad \\tilde h=\\frac{Kh-1}{K-1}$, and the absolute-value form in Eq. 8 is a **practical extension**, not an exact theorem when $\\Gamma(h)<0$. We will restrict all exact claims to the positive-signal regime.\n\nThe structurally uninformative point is not $h=0$, but the class-random baseline $h=1/K$. Normalization maps this point to $\\tilde h=0$, so $|\\tilde h|$ measures distance from a random neighborhood and motivates a symmetric signal-strength parametrization. This motivates the extension but does not prove Bayes optimality under class-order reversal.\n\nIt is also essential to distinguish $\\tilde h<0$ from genuinely negative total signal. Because the GCN contains a self-loop,\n$$\\Gamma(h)<0\\iff h<h_0,\\quad h_0=\\frac{1-(K-1)/\\bar d}{K}$$.\n\n| Regime | Homophilic datasets | Heterophilic datasets |\n|---|---:|---:|\n| estimated $\\tilde h<0$ | 1.0% | 37.6% |\n| estimated $\\tilde h<0.2$ | 4.0% | 35.6% |\n| oracle diagnostic $\\Gamma(h)<0$ | **0.6%** | **15.4%** |\n\nThus, negative normalized homophily is common on heterophilic graphs, but the genuinely order-reversing region is much smaller. It is 0.0% on Roman-Empire, 6.7%/8.4% on Texas/Cornell, and 29.3%/31.6% on Chameleon/Squirrel. Oracle $h$ is used only for this retrospective diagnosis.\n\nOn evaluable $\\Gamma(h)<0$ subsets, $\\mathrm{ECE}_{\\mathrm{HoTS}}-\\mathrm{ECE}_{\\mathrm{Ent}}$ averages **−1.19 pp**, with improvements on 3/5 datasets and small losses on two. This does not establish optimality outside the theorem; it shows no systematic empirical collapse from the extension.\n\nWe will also extend Fig. 1(a) over the full range and plot both raw $h$ and normalized $\\tilde h$, marking $1/K$ and $h_0$ and shading $\\Gamma<0$. For the reviewer's question about empirical behavior, the relevant quantity is the temperature HoTS actually applies, which we recover per node from the stored logits and calibrated outputs. On pooled heterophilic nodes this applied temperature is mild and bounded across the entire range (≈0.7–1.1, with mean and median nearly coinciding): it is ≈1.0 near the random point $\\tilde h\\approx0$ and decreases to ≈0.7 (mild sharpening) as $\\tilde h$ becomes strongly negative. Although the $1/|\\tilde h|^{\\alpha}$ factor in Eq. 8 diverges as $\\tilde h\\to0$, the temperature actually applied does not, so there is no low-homophily temperature spike.\n\nOur revised claim is therefore precise: \n> **the theory establishes the inverse law in the positive-signal regime; Eq. 8 is an empirical positive-temperature extension whose exercised region and behavior are quantified above.**\n\n---\nWe sincerely appreciate your thoughtful engagement with our research and would welcome the opportunity to respond to any additional feedback !"+ },+ "createdAt": "2026-07-27T13:20:04.283Z",+ "modifiedAt": "2026-11-18T17:18:24.655Z",+ "url": "https://openreview.net/forum?id=woxrGUwgJ3¬eId=X4p8sMtQMg",+ "license": "CC-BY-4.0"+}
reviews/openreview/woxrguwgj3/submission.json added
+++ b/reviews/openreview/woxrguwgj3/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "woxrGUwgJ3",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 20840,+ "url": "https://openreview.net/forum?id=woxrGUwgJ3",+ "license": "CC-BY-4.0"+}
versions/v_g7d9geja.json added
+++ b/versions/v_g7d9geja.json@@ -0,0 +1,22 @@+{+ "date": "2026-05-04",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 20840,+ "url": "https://openreview.net/forum?id=woxrGUwgJ3",+ "reviews": "openreview/woxrguwgj3",+ "evidence": [+ "https://openreview.net/forum?id=woxrGUwgJ3"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=woxrGUwgJ3",+ "evidence": [+ "https://openreview.net/forum?id=woxrGUwgJ3"+ ]+}