Import NeurIPS 2026 submission 2DhyeIm0FC: 8 notes
@openreview[bot] · 2026-11-22 17:53 UTC · fdb6a8e3fad5 ·
reviews/openreview/2dhyeim0fc/forms.json added
+++ b/reviews/openreview/2dhyeim0fc/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/2dhyeim0fc/notes/guyfi0m9u4.json added
+++ b/reviews/openreview/2dhyeim0fc/notes/guyfi0m9u4.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "GUYFI0M9u4",+ "replyTo": "Rx3aQaim72",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for the close and specific questions. We answer all six points below and state the change we will make in each case.\n\n### **W1. Rationale for the baseline selection.** ###\n\nYou are right that the paper names the six methods without saying why those six. The set follows the architectural families in our related work, one representative from each, plus our own backbone as a control.\n\npix2pix and CycleGAN are the paired and unpaired GAN pipelines that established cross-stain translation, and most prior work in this area carries them as benchmark models. PSPStain is the pathology-specific GAN designed for H&E to IHC. D-VST is the diffusion transformer line. UNIStainNet is the foundation-model-guided line, and it is the closest prior work to ours because it also conditions on a pathology VFM. UNSB is the Schrödinger Bridge backbone we build on, so it isolates what our components add.\n\nTwo further conditions applied. Each method must release source code, since we retrain all of them rather than reuse published results. Published numbers on these datasets come from a different patch size and a different evaluation protocol, so they would not sit on the same scale as ours. Apart from the backbone, each is also one this literature already benchmarks against, whether as a published H&E to IHC method or as the general translation baseline that the BCI and MIST papers themselves include. CC-WSI-Net, which another reviewer raised, targets patch stitching and would have fit the set well, but it does not release code. The paper states that we retrain from publicly available source code, but it does not give the reasoning above. We will add it to the experimental setup, together with the methods we considered and could not include.\n\n### **W2 and Q4. Rationale for the hyperparameter values, and the effect of different configurations.** ###\n\nThe paper lists seven loss weights, and they were not all set in the same way.\n\n$\\lambda\\_{\\text{SB}}$, $\\lambda\\_{\\text{NCE}}$ and $\\lambda\\_{\\text{sheaf}}$ are all 1 and none of them was varied in any run. The UNSB paper sets its bridge weight to 1, and the UNSB baseline in Table 1 is trained with the same weights we use, so the ablation adds our components without changing the backbone weighting. $\\lambda\\_{\\text{sheaf}}$ is fixed at 1 by construction, since the sheaf term is the objective the paper is about and therefore carries the unit scale that the auxiliary weights are expressed against.\n\n$\\lambda\\_{\\text{stain-align}}$ is 1 whenever the term is active. What we set for it is a schedule rather than a magnitude, since the term is off for epochs 1 to 350 and on for the last 50 of 400.\n\nThat leaves the auxiliary weights, which we set by a coarse grid over $\\lbrace 0.1, 0.5, 1.0\\rbrace$, one order of magnitude apart. The search ran in two stages: a component ablation to decide which terms belong in the objective at all, which is Table 1, and then the weight grid. One setting is used everywhere in the paper. BCI and all four MIST markers share it with no per-dataset retuning.\n\nOn how configurations affect performance, the axis with the largest effect is the pixel sheaf balance $\\alpha$. With $\\alpha = 1$, all 8 settings land in a narrow band, FID 43.7 to 54.8. With $\\alpha$ below 1, only 7 of 18 settings reach that band and the worst reaches FID 164. Inside the $\\alpha = 1$ region the remaining weights move the result much less. The 26 settings below vary the cocycle, Fourier and $\\alpha$ weights with the DAB weight held at 0.1, and each row reports the per-metric value across those settings rather than one configuration. The grid runs use a shortened 100-epoch schedule for screening, so these values are not the ones the paper reports. The same setting trained for the full 400 epochs reaches FID 36.36 on this block.\n\n|Setting|FID|KID|LPIPS|DISTS|\n|---|---|---|---|---|\n|Selected|46.65|0.0123|0.4816|0.2270|\n|Best in grid|43.71|0.0082|0.4772|0.2261|\n|Median of grid|54.70|0.0195|0.5064|0.2600|\n|Worst in grid|164.00|0.1653|0.6181|0.3255|\n\nThe selected setting is second of 26 on mean rank over these four metrics and it is not the best on any of them. It is the best on DISTS among the $\\alpha = 1$ settings, and its gap to the grid best is 0.4% on DISTS and 0.9% on LPIPS, inside the range where settings are not distinguishable. The cocycle weight of 0.1 has the lowest mean FID of its three values, 54.8 against 71.9 and 71.5. We read this as the outcome depending on the structure of the objective and on $\\alpha$, rather than on a precise weighting of the auxiliary terms. We will add the grid, the two-stage procedure, and this reading to the hyperparameter appendix.\n\n### **Q1. Do the three issues in Figure 1 overlap?** ###\n\nThey do, and you are right that stain-tone drift and chromatin-distribution mismatch both surface at patch boundaries. The three are not independent failure modes, and the paper does treat them as one cause with three manifestations. The Figure 1 caption states that independent patch translation induces all three, and Section 1 describes how inter-patch inconsistencies translate directly into stitching artifacts and tone discontinuities in the reassembled region.\n\nWhat separates them is where they act and what responds to them. Tone drift is a property of a whole patch relative to its neighbors, and it shifts the chromogen readout that biomarker scoring depends on. Chromatin mismatch is a within-patch texture property that changes nuclear appearance. Boundary discontinuity is the geometric signature at the seam, and it is what the Tiling Score measures. A method can reduce the seam and leave the tone wrong, which is why we report them separately.\n\nThe caption carries the shared cause in a single word, induces, which is easy to read past. We will make it explicit that (a), (b) and (c) are three ways one failure becomes visible, and name the metric that responds to each.\n\n### **Q2. Meaning of the bolded rows in Table 1.** ###\n\nBold in Table 1 marks the final row, which is the complete model, and it does not mark the best value in a column. Table 3 uses bold for the best value. Carrying two meanings on one form of emphasis without saying so is a defect on our side, and the caption should have stated the convention.\n\nWe will make Table 1 follow Table 3, so that bold marks the best value in each column and the complete model is identified by its row label instead. Under that convention the final row is best on FID, LPIPS, DISTS and DAB-r, while KID is best at the DAB intensity step and Tiling Score at the pixel sheaf step. The paper already says as much in the text, where we note that TS plateaus after the pixel sheaf loss.\n\nOne point about the DAB-r column. A transpose in our color deconvolution meant that column was computed on the wrong stain channel, and the corrected values appear in our response to Reviewer 1. The ordering within the column does not change, so the statement above holds either way.\n\n### **Q3. The MIST ground truth in Figure 4, and how reliable the outputs are.** ###\n\nOn the pair. That row is `4M2103059_22_9.jpg`, which appears under the same filename in the `val_HE` and the `val_IHC` folder of the MIST HER2 release [A], so it is the pair the dataset itself provides, and the tissue structure agrees between the two. What differs is the color. That field carries almost no chromogen, with strong DAB covering 7.9% of its area, so the IHC image is dominated by a light counterstain while the H&E image is strongly eosinophilic. Side by side the two look unrelated even though they show the same tissue. MIST pairs are also cut from consecutive sections, so they are neighboring slices rather than one physical plane. We will note both points in the caption.\n\nOn reliability. Exact agreement with the reference is not the right target here, for the reason just given. The reference is a different physical section, so a pixel-level match is not attainable by any method. We therefore test whether the outputs carry the biological signal, with a protocol that does not depend on appearance. We train a HER2 Low/High classifier on translated outputs alone and evaluate it on real IHC from the BCI test set (Table 2).\n\n|Classifier trained on|Acc|F1|AUROC|\n|---|---|---|---|\n|D-VST|0.658|0.761|0.650|\n|UNIStainNet|0.724|0.835|0.737|\n|SheafStain|0.766|0.844|0.794|\n\nFeatures that are artifacts of a generator do not transfer to real IHC, while features that encode HER2 grade do, whatever the texture statistics of the synthetic images look like. Under this protocol SheafStain is ahead on all three measures, and its margin over UNIStainNet is 4.2 points of accuracy and 0.057 AUROC. That is the level at which we claim the outputs are usable, and we will make that scope explicit in the paper.\n\n### **References** ###\n\n[A] F. Li, Z. Hu, W. Chen, and A. Kak. Adaptive supervised PatchNCE loss for learning H&E-to-IHC stain translation with inconsistent groundtruth image pairs. MICCAI, 2023."+ },+ "createdAt": "2026-07-27T10:03:37.359Z",+ "modifiedAt": "2026-11-18T17:18:44.289Z",+ "url": "https://openreview.net/forum?id=2DhyeIm0FC¬eId=GUYFI0M9u4",+ "license": "CC-BY-4.0"+}
reviews/openreview/2dhyeim0fc/notes/juulpeesyr.json added
+++ b/reviews/openreview/2dhyeim0fc/notes/juulpeesyr.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "JuUlpEESyr",+ "replyTo": "neTj9rtW7l",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We appreciate the reviewer's engagement with the sheaf framing and the assessment that the implementation and ablation are sound. We accept the clarity criticism. The paper compresses the sheaf material into a few dense paragraphs and defers the definitions to the appendix, which makes the main text hard to follow on a first pass. We answer the three questions below and state what we will change.\n\n### **On the terminology at line 169 (patches and stalks).** ###\n\nYou are right, and we will fix the usage. A patch is an open set $U\\_i$ of the cover, its VFM embedding is a section $s\\_i = \\Phi(U\\_i) \\in \\mathcal{F}(U\\_i)$ over that open set, and a stalk is the direct limit $\\mathcal{F}\\_x := \\varinjlim\\_{x \\in U} \\mathcal{F}(U)$ at a point, whose elements are germs. A patch embedding is a section, not a stalk.\n\nAppendix A gives the formal definition and notes that we used the word loosely, and the formal statements involving restriction maps are already written in terms of sections. That qualification belongs where the reader meets the term. We will replace every loose use with \"section over $U\\_i$\" in the main text and keep the formal definition in Appendix A as the reference. The model, the losses, and the experiments are unaffected. What changes is the wording.\n\n### **Q1. Why the sheaf view is suited to virtual staining rather than to WSI modeling in general.** ###\n\nVirtual staining is a setting where a failure of local-to-global consistency has direct and measurable consequences. In a discriminative whole-slide image (WSI) task the same disagreement is pooled away. Here it survives into the output a pathologist reads. The framework is not exclusive to virtual staining, and it applies wherever a WSI is assembled from overlapping patch-level computations, which is the setting our measurements cover. Our claim is the narrower one, and three properties make it so.\n\nThe defect is measured, not assumed. VFM embeddings of overlapping patches disagree on their shared region, with cosine similarity between corresponding overlap tokens ranging from 0.63 at 14% overlap to 0.92 at 86% overlap, consistently below 1 across 4,873 images, eight strides, four directions, and both stains (Section 3.2, Appendix I). Of the two sheaf axioms, locality is immediate here, since a section is determined by its token positions. Because the embeddings disagree on overlaps, they fail to satisfy the compatibility required for gluing, and no single global section restricts to them. If such a section existed, its restrictions would agree on every overlap by the definition of the restriction maps, contradicting the observed incompatibility. The Dirichlet energy $E(x) > 0$ measures the size of that disagreement, and the pixel sheaf and cocycle losses reduce it directly. We will use this phrasing in the paper.\n\nThe output is consumed as an assembled image. Disagreement between two patches on their overlap appears as a seam and a tone discontinuity in the stitched region, which is what a pathologist reads.\n\nThe readout integrates over the assembled region. Chromogen amount and its spatial distribution are computed on the stitched output, so patches that are individually plausible but mutually inconsistent give the wrong measurement.\n\nThe contrast with discriminative WSI tasks is informative. In slide-level classification, patch features are pooled, and pooling is largely invariant to the local disagreements above. The same defect is therefore harmless there and harmful here. Whether it carries to other patch-assembled WSI tasks is open, and we will list it with the WSI-scale validation we already give as future work. This paper asks the narrower question of whether it holds in virtual staining, where the failure is measurable and the output is read as an assembled image. We will state this scope in the paper.\n\n### **Q2. How important the Schrödinger Bridge is, and how the experiments justify it.** ###\n\nSchrödinger Bridge (SB) is the generative backbone we build on. We do not claim it as a contribution of this work, and the title should not have suggested otherwise without an explanation in the text.\n\nIts role is precise. SB defines the transport from the H&E marginal $\\pi\\_0$ to the IHC marginal $\\pi\\_1$ under entropic regularization,\n\n$Q\\_{\\mathrm{SB}} = \\arg\\min\\_{Q \\in \\mathcal{D}(\\pi\\_0,\\pi\\_1)} \\mathrm{KL}(Q \\|| W^\\tau)$,\n\nand we inherit UNSB's neural realization of it. Our contribution enters as structural regularizers on that same objective,\n\n$Q^{\\ast} \\in \\arg\\min\\_{Q \\in \\mathcal{D}(\\pi\\_0,\\pi\\_1)} [\\mathrm{KL}(Q \\|| W^\\tau) + \\sum\\_k \\lambda\\_k \\mathcal{R}\\_k(Q)]$,\n\nwhere the $\\mathcal{R}\\_k$ are the pixel sheaf and cocycle terms (Appendix B). We also show there that these regularizers act on the coupling and leave the marginals intact.\n\nWe use SB because virtual staining observes both marginals. Entropic transport between two observed distributions is a closer fit than starting from a noise prior. This is also the reason UNSB gives for building on SB, namely that the Gaussian prior assumption limits diffusion models on unpaired translation [A]. Our paper states this in Section 2 in a single sentence, and we will move it into the method section.\n\nOn the ablation, the first row labeled \"Baseline\" is UNSB, that is the SB backbone with none of our components, and every later row adds one of our components to it. The ablation therefore measures our contributions against plain SB throughout. FID falls from 227.79 for the backbone alone to 36.36 for the full model, and DAB-r rises from 0.0589 to 0.1209. The DAB values differ from the submitted table because the stain deconvolution in our evaluation code used the transpose of the inverse stain matrix rather than the inverse, so it read the wrong channel. We fixed this and recomputed the DAB metrics for every method. No other metric is affected. The label was uninformative and we will rename it \"Baseline (UNSB)\".\n\n### **Q3. Context for choosing BCI and MIST.** ###\n\nThe choice follows from what the claim needs to be testable. Our subject is patch assembly under weak pairing, so the data has to supply an IHC reference that corresponds spatially to a region wide enough to contain interior patch boundaries, and it has to come from the consecutive-section regime that produces the weak pairing in the first place. BCI and MIST both ship registered 1024×1024 pairs cut from consecutive sections, which our protocol divides into 16 patches with 24 interior seams. BCI gives one HER2 partition with an official train and test split. MIST gives four markers (HER2, ER, PR, Ki-67), which lets us check whether the method transfers across biomarkers instead of fitting one. They are also the standard evaluation sets for this task, which is why we retrain every method on them ourselves rather than carry over published numbers.\n\nTwo public alternatives are worth naming. HER2match [B] is same-section and better registered, but the weak pairing is a property of the task itself. Only one stain can be applied to a given section, so an H&E field and its IHC counterpart come from different sections, and the re-staining protocols that avoid this bring their own tissue damage and registration drift, as Section 1 notes. Evaluating on a same-section benchmark would remove the condition the method is built to handle, and it would also change the scanner and the acquisition domain. IHC4BC [C] meets both conditions. It is public, covers the same four markers, and comes from the same consecutive-section regime. We kept this study on the two sets the compared methods already report on, so that our retrained numbers can be checked against published ones, and adding a third means retraining all seven methods on a release of about 90,000 pairs from 240 slide pairs. We will name IHC4BC in the first limitation as the concrete next step.\n\n### **On introducing virtual staining and the sheaf vocabulary.** ###\n\nWe agree with your comment, and this is the change we expect to help most. The introduction does motivate the problem in its opening sentences, since IHC is central to biomarker diagnostics, only one stain can be applied to a given section, and this imposes resource and turnaround costs. What it never does is state plainly what virtual staining is, namely predicting the appearance of an IHC stain from an H&E image of the same tissue. We will add that sentence, and a worked example of the vocabulary on one concrete pair of overlapping patches, so that a reader without prior exposure to sheaves can follow Section 3.2 without going to the appendix.\n\n### **Here are the changes in one place.**\n\nWe will state plainly what virtual staining is and work the sheaf vocabulary through one concrete pair of overlapping patches. We will use \"section over $U_i$\" in the main text and keep the formal definition in Appendix A. We will move the reason for building on a Schrödinger Bridge into the method section, rename the ablation baseline to \"Baseline (UNSB)\", and name IHC4BC in the first limitation as the next dataset. You write that the density made the work hard to evaluate in detail, and these are the edits that should close that gap.\n\n\n### **References** ###\n\n[A] B. Kim, G. Kwon, K. Kim, J. C. Ye. Unpaired image-to-image translation via neural Schrodinger bridge. ICLR, 2024.\n\n[B] P. Klöckner et al. GANs vs. diffusion models for virtual staining with the HER2match dataset. Deep Generative Models, 2025.\n\n[C] A. Akbarnejad, N. Ray, P. J. Barnes, G. Bigras. Predicting Ki67, ER, PR, and HER2 statuses from H&E-stained breast cancer images. arXiv preprint arXiv:2308.01982, 2023."+ },+ "createdAt": "2026-07-27T10:02:22.965Z",+ "modifiedAt": "2026-11-18T17:18:44.328Z",+ "url": "https://openreview.net/forum?id=2DhyeIm0FC¬eId=JuUlpEESyr",+ "license": "CC-BY-4.0"+}
reviews/openreview/2dhyeim0fc/notes/lw0qhzqeve.json added
+++ b/reviews/openreview/2dhyeim0fc/notes/lw0qhzqeve.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "lW0QhzQeVe",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "This paper addresses virtual staining in histopathology by identifying \"context contamination\" in VFM embeddings as a source of patch-boundary inconsistencies and proposing SheafStain, which combines sheaf-theoretic consistency constraints with a Schrödinger Bridge framework to improve spatial and biological coherence in stitched outputs. Reviewers found the problem interesting, the empirical analysis of embedding inconsistency novel, and the experimental evaluation extensive, with gains over prior methods and an evaluation protocol that reflects well deployment by assessing stitched regions rather than isolated patches. However, several concerns remain. For the rebuttal, please focus on clarifying the technical role of the sheaf formulation and the Schrödinger Bridge component, and provide stronger justification for key modeling choices. Please also address the biological importance of the results given the low absolute DAB correlation values, including estimates of the ceiling under weakly paired consecutive-section data and the implications for claims of biological coherence. Additionally, discuss the impact of the method’s computational cost, justify dataset and baseline selection, explain hyperparameter choices, and reconcile the interpretation of metrics where the method underperforms.",+ "final_justification": "I have read the authors’ response and the subsequent reviewer discussion. The rebuttal addressed most of the concerns from my initial meta-review, including dataset and baseline selection, hyperparameter choices, the interpretation of the low DAB-correlation values, the impact of weakly paired consecutive-section data, and the evaluation protocol. Two reviewers indicated that their concerns were resolved and maintained positive assessments. The authors disclosed and corrected an error in the DAB color-deconvolution evaluation, re-reporting the affected metrics and explaining its impact on the results. While I commend this transparency and do not believe the correction changes the conclusions, the need for a post-submission fix introduces some uncertainty and slightly reduces my confidence. Reviewer SEWY remained unconvinced after rebuttal, primarily because the density of the presentation and complexity of the sheaf-theoretic formulation made it difficult to verify a central technical contribution within the review period. I consider this a legitimate concern, although no reviewer identified a concrete mathematical flaw. At the same time, the paper presents a solid empirical contribution, including a novel analysis of context contamination in pathology VFMs, a method for improving coherence across stitched regions, a realistic evaluation protocol, and consistently strong results across multiple benchmarks. Balancing these strengths against the remaining concerns, I view the paper as borderline but ultimately on the positive side of the acceptance threshold. I therefore recommend Accept (Poster), with the expectation that the authors significantly improve the clarity and accessibility of the sheaf-theoretic component in the final version."+ },+ "createdAt": "2026-09-24T11:23:42.695Z",+ "modifiedAt": "2026-11-18T14:57:00.397Z",+ "url": "https://openreview.net/forum?id=2DhyeIm0FC¬eId=lW0QhzQeVe",+ "license": "CC-BY-4.0"+}
reviews/openreview/2dhyeim0fc/notes/mrswjqbobj.json added
+++ b/reviews/openreview/2dhyeim0fc/notes/mrswjqbobj.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "mrSwJQBObj",+ "replyTo": "PdMwDqt7WY",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We thank the reviewer for the thorough and constructive review, and for recognizing the practical importance of the problem, the presheaf analysis in Section 3.2, and the stitched-region evaluation protocol.\n\n### **Correction (applies to all DAB-based metrics).** ###\n\nIn preparing this response we found an error in our DAB color deconvolution. The DAB metrics require projecting the optical-density image onto stain concentrations with the inverse of the H-DAB stain matrix M. Our code computed `od @ inv(M).T` instead of `od @ inv(M)`, so the channel we read as DAB was not DAB. On a unit-concentration pure DAB input that channel responds -0.69, and on a pure hematoxylin input it responds +1.31. The maps we reported were therefore hematoxylin-dominated with an inverted DAB response. \n\nThe fix removes the transpose from one line of the evaluation code, identically for all seven methods, with no retraining, no change to the generated images, and no change to the evaluation data or splits. Only the DAB-derived metrics change, and FID, KID, LPIPS, DISTS, PSNR, SSIM and TS are untouched. DAB-r rises in all 35 (dataset, stain, method) entries, the other DAB metrics move in both directions, and FOD decreases in most of them. The ranking changes in one of the five blocks, since the best DAB-r on BCI is now UNIStainNet.\n\n**Corrected values at 1024×1024. Best in bold, second-best in italics.**\n\n*BCI (HER2 only)*\n\n|**Method**|**DAB-r↑**|**DAB-KL↓**|**DAB-JSD↓**|**mIOD↓**|**FOD↓**|\n|---|---|---|---|---|---|\n|pix2pix|0.0559|*0.8688*|**0.1085**|*0.0838*|**0.0866**|\n|CycleGAN|0.0668|2.7118|0.3006|0.1479|0.1954|\n|PSPStain|0.0317|1.9180|0.2276|0.1174|0.1679|\n|D-VST|0.0736|**0.8404**|0.1346|0.1172|*0.1003*|\n|UNIStainNet|**0.1267**|1.1834|0.1591|0.0946|0.1280|\n|UNSB|0.0589|1.0434|0.2164|0.1674|0.2227|\n|SheafStain (Ours)|*0.1209*|1.2226|*0.1255*|**0.0615**|0.1149|\n\n*MIST HER2*\n\n|**Method**|**DAB-r↑**|**DAB-KL↓**|**DAB-JSD↓**|**mIOD↓**|**FOD↓**|\n|---|---|---|---|---|---|\n|pix2pix|*0.0866*|1.2894|0.1286|0.2195|0.1877|\n|CycleGAN|0.0681|0.9302|0.1401|0.2525|0.2057|\n|PSPStain|0.0841|0.6306|0.1109|*0.1676*|0.1964|\n|D-VST|0.0356|*0.4840*|*0.1025*|0.1964|*0.1837*|\n|UNIStainNet|0.0606|1.2083|0.2222|0.4749|0.2613|\n|UNSB|0.0310|0.8462|0.1452|0.2648|0.2137|\n|SheafStain (Ours)|**0.1187**|**0.3447**|**0.0704**|**0.0714**|**0.1650**|\n\n*MIST ER*\n\n|**Method**|**DAB-r↑**|**DAB-KL↓**|**DAB-JSD↓**|**mIOD↓**|**FOD↓**|\n|---|---|---|---|---|---|\n|pix2pix|0.0551|1.9522|0.1686|0.2991|0.2119|\n|CycleGAN|0.0884|0.8162|0.1386|0.2728|0.2355|\n|PSPStain|*0.0906*|0.5176|*0.0999*|*0.1963*|*0.1852*|\n|D-VST|0.0554|*0.4522*|0.1072|0.2526|0.2226|\n|UNIStainNet|0.0497|1.2837|0.1288|0.2801|0.2170|\n|UNSB|0.0790|0.8176|0.1305|0.2698|0.2341|\n|SheafStain (Ours)|**0.1248**|**0.3890**|**0.0794**|**0.0794**|**0.1692**|\n\n*MIST PR*\n\n|**Method**|**DAB-r↑**|**DAB-KL↓**|**DAB-JSD↓**|**mIOD↓**|**FOD↓**|\n|---|---|---|---|---|---|\n|pix2pix|0.0656|1.6081|0.1523|0.3132|0.1937|\n|CycleGAN|0.0823|0.6455|0.1347|0.2945|0.2219|\n|PSPStain|*0.0905*|*0.4411*|*0.0900*|*0.2205*|*0.1783*|\n|D-VST|0.0502|0.4854|0.1170|0.2741|0.2229|\n|UNIStainNet|0.0429|3.0349|0.1885|0.3395|0.3417|\n|UNSB|0.0544|1.1273|0.1546|0.3181|0.2527|\n|SheafStain (Ours)|**0.1184**|**0.3572**|**0.0772**|**0.0954**|**0.1676**|\n\n*MIST Ki-67*\n\n|**Method**|**DAB-r↑**|**DAB-KL↓**|**DAB-JSD↓**|**mIOD↓**|**FOD↓**|\n|---|---|---|---|---|---|\n|pix2pix|0.0257|0.7639|0.1202|0.1490|**0.2067**|\n|CycleGAN|*0.0423*|0.7734|0.1323|0.1384|0.2412|\n|PSPStain|0.0340|0.5525|0.1052|*0.1135*|0.2134|\n|D-VST|0.0235|**0.4586**|*0.1036*|0.1267|0.2191|\n|UNIStainNet|0.0200|0.6261|0.1339|0.1163|0.2735|\n|UNSB|0.0326|0.6734|0.1299|0.1400|0.2585|\n|SheafStain (Ours)|**0.0493**|*0.5217*|**0.1001**|**0.0750**|*0.2072*|\n\nSheafStain has the best DAB-r on four of five (dataset, stain) blocks, all four MIST markers, and is second on BCI. On MIST HER2, ER and PR it is best on all five metrics. On MIST Ki-67 it is best on DAB-r, DAB-JSD and mIOD, and second on DAB-KL and FOD. On BCI it is best on mIOD and second on DAB-r and DAB-JSD.\n\n**Ablation on BCI. Only DAB-r changes. FID, KID, LPIPS, DISTS and TS are unchanged.**\n\n|**Step**|**DAB-r (submitted)**|**DAB-r (corrected)**|\n|---|---|---|\n|Baseline (UNSB)|0.0028|0.0589|\n|+ Spatial Cond.|0.0211|0.0823|\n|+ Pixel Sheaf|0.0101|0.1059|\n|+ Cocycle|0.0084|0.1091|\n|+ Fourier Edge|0.0255|0.1190|\n|+ DAB Intensity|0.0247|0.1183|\n|+ Cross-stain Align. (Ours)|0.0267|0.1209|\n\nThe correction also clarifies the component analysis. Under the corrected values DAB-r rises across the sheaf-related steps, most notably at the pixel sheaf and cocycle terms where the submitted numbers dipped. The sheaf objectives therefore improve biomarker localization on their own, and the Fourier edge term adds a further gain. We will revise the ablation result accordingly.\n\n### **W1 and Question (low DAB-r, and the theoretical ceiling under weak pairing).** ###\n\nWe agree, and we investigated the ceiling directly. Because H&E and IHC are cut from two different tissue sections [A], the reference is spatially and biologically offset from the input, which bounds DAB-r for any model. On the full evaluation splits we correlate each ground-truth DAB map with a displaced copy of itself. At the BCI resolution of 0.46 µm/px [A]:\n\n|**Displacement**|**0.9 µm**|**3.7 µm**|**7.4 µm**|**14.7 µm**|**29.4 µm**|\n|---|---|---|---|---|---|\n|Attainable DAB-r|0.89|0.57|0.40|0.27|0.19|\n\nA calibrated elastic warp of the same mean magnitude gives comparable values (0.46 at 7.4 µm and 0.33 at 14.7 µm) and is insensitive to the warp smoothness. Consecutive sections retain a median registration residual of 6.5 to 24.1 µm even after non-rigid registration [B], so a perfect but misaligned predictor is capped at roughly 0.21 to 0.43. The metric is intrinsically compressed, since a displacement of one micron already reduces it to about 0.89. Observed values fall below even this geometric bound because the two sections also differ biologically, which registration cannot recover. This is why no method exceeds about 0.13.\n\nWe therefore make the biological-coherence claim precise and support it with evidence that is insensitive to this misalignment. SheafStain leads DAB-r on four of five blocks and leads all five biomarker metrics on three of the four MIST blocks. On downstream HER2 Low/High classification on real BCI data it leads accuracy, F1 and AUROC, exceeding the strongest prior method by 4.2 points of accuracy and 0.057 AUROC. We will add this ceiling analysis and scope the coherence claim accordingly.\n\n### **W2 (computational cost).** ###\n\nYou are right. On the latency-quality trade-off in Appendix L, SheafStain sits at the high-quality end of the non-dominated Pareto frontier, so no faster method reaches its FID or DAB-r there. The per-image cost splits into the VFM forward (about 90 percent) and the generator (about 10 percent). The VFM forward is a swappable component: the backbone comparison below shows Virchow2 matching quality at lower cost. The many per-patch calls come from giving each patch its own neighborhood context, which is what the sheaf objective operates on, so this compute is the source of the FID, TS, and DAB-r gains. Virtual staining runs offline as a batch preprocessing step, so the hours per slide are set against the turnaround of the IHC assay it replaces. The measurements below use the protocol and GPU of Appendix L on MIST HER2.\n\n|**VFM backbone**|**VFM params**|**TFLOPs/img**|**Latency**|**FID**|**DAB-r**|\n|---|---|---|---|---|---|\n|Prov-GigaPath ViT-G (default)|1135 M|44.7|17.6 s|34.51|0.1187|\n|UNI2-h ViT-H|681 M|35.0|14.0 s|65.14|0.0843|\n|Virchow2 ViT-H|631 M|32.9|13.4 s|33.60|0.1239|\n\n### **W3 (PSNR/SSIM and metric objectivity).** ###\n\nThis is a reasonable concern. What separates the full-reference metrics is their sensitivity to spatial misalignment. PSNR and SSIM are pixel-aligned and degrade under sub-cellular displacement, the same mechanism that produces the DAB-r ceiling above. DISTS is constructed to be relatively insensitive to geometric transformations such as translation and dilation [C], and LPIPS is likewise more tolerant, while FID and KID use no pairing at all. We report PSNR and SSIM for every block in the paper and will keep them there.\n\n### **W4 (evaluation scale stops at 1024).** ###\n\nWe agree that larger-scale evaluation would strengthen the WSI motivation. We evaluate at 1024 because it already exposes the inter-patch inconsistency the method targets, with 16 patches and 24 internal boundaries. BCI and MIST are released as paired 1024 regions and do not provide larger contiguous paired context. The same-section dataset HER2match [D] is one candidate for scaling up, but re-staining changes the pairing regime the method targets, and it is a different acquisition domain with a different scanner, so a fair evaluation would require retraining on that domain. We will list this and other public cohorts as concrete future work.\n\n### **W5 (CC-WSI-Net not compared).** ###\n\nThank you for the pointer. CC-WSI-Net does not release public code, so we cannot reproduce it under our controlled 256-to-1024 stitched protocol. The paper introduces it in related work but does not contrast it with ours. We will state the difference, that it repairs stitching after the fact while we constrain the overlaps during generation.\n\n### **Limitations (computational cost not listed).** ###\n\nWe will add computational cost as a fourth limitation alongside the three already stated.\n\n### **References** ###\n\n[A] S. Liu et al. BCI: Breast cancer immunohistochemical image generation through pyramid pix2pix. CVPRW, 2022.\n\n[B] J. Lotz et al. Comparison of consecutive and restained sections for image registration in histopathology. JMI, 2023.\n\n[C] K. Ding et al. Image quality assessment: unifying structure and texture similarity. TPAMI, 2022.\n\n[D] P. Klöckner et al. GANs vs. diffusion models for virtual staining with the HER2match dataset. Deep Generative Models, 2025."+ },+ "createdAt": "2026-07-27T09:49:27.348Z",+ "modifiedAt": "2026-11-18T17:18:44.270Z",+ "url": "https://openreview.net/forum?id=2DhyeIm0FC¬eId=mrSwJQBObj",+ "license": "CC-BY-4.0"+}
reviews/openreview/2dhyeim0fc/notes/netj9rtw7l.json added
+++ b/reviews/openreview/2dhyeim0fc/notes/netj9rtw7l.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "neTj9rtW7l",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer SEWY",+ "content": {+ "summary": "This paper seeks to address an established but important problem in cell and tissue microscopy called virtual staining—inferring what slides would look like under stains other than the one actually applied. The authors argue that patchwise incoherence arising from the vision transformer architectures are a major performance barrier, and mitigate this by infusing learning with concepts from sheaf theory, a mathematical construction for reconciling local spatial information into a coherent global whole. Experiments and analyses validate the improvements offered by their method.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "The paper addresses an important problem in biomedical AI by incorporating ideas from an appropriate, deep theoretical framework in mathematics. This is a major strength, if implemented soundly, because it enables deep learning algorithms to leverage frameworks already developed comprehensively in mathematics—compared to many methods which hack together isolated fixes. \n\nOn a technical level, the implementation—analysis, modeling, and evaluation—seem sound and impressively comprehensive, at least in broad strokes. The ablation study looks comprehensive.\n\nMy main issue with the paper is it is extremely dense and fails to properly introduce or explain many key concepts, making it hard to evaluate many aspects of the paper in detail. \n\nFor instance:\n* The paper should explain what virtual staining is and why it is important.\n* The paper’s discussion of sheaves essentially assumes prior familiarity with this complex mathematical concept which is not used in most/any other areas of AI or computer science. Perhaps because of its terseness, its developments do not always seem sound. For instance, it’s unclear why slide image patches are equated with stalks (line 169)—patches seem to be more like open subsets, whereas stalks should be idealized limits at a point.\n* The paper does not clearly explain why their sheaves methodology helps solve their specific problem of virtual staining, rather than, for instance, any WSI modeling or even large-scale computer vision tasks in general.\n* The paper advertises the sophisticated-sounding concept of the Schrodinger Bridge (SB) prominently in the title, and then refers to it by acronym only in Sections 1 and 2, before introducing it in a sentence fragment in Section 3, and then barely mentioning it at all in the rest of the paper. It is not clear whether SB is an overt feature contribution, e.g., it doesn’t to seem to be in the ablation study.\n\nIt is hard to evaluate the paper in detail methodologically given the unclarity stemming from the above concerns. But one additional concern is that while the paper acknowledges that its choice of just BCI and MIST for evaluation is a limitation, it does not provide context such as western the are the two most established datasets for this task, what other datasets might exist, why these were chosen among those options, etc.",+ "quality": 3,+ "clarity": 2,+ "significance": 3,+ "originality": 3,+ "questions": "1. What makes the sheaves methodology specifically suitable for virtual staining rather than other WSI or high-res computer vision tasks in general?\n2. How important is the Schrodinger Bridge to the overall methodology, and how do the experiments (e.g., ablation) justify this?\n3. What is the context and justification for choosing BCI and MIST as the evaluation set?",+ "limitations": "More context and justification for choosing BCI and MIST as the evaluation set would be helpful.",+ "rating": 3,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "My main concern after my initial review was that the density of the paper (and some mistakes and unclear writing) made it hard to fully evaluate the soundness of their main technical contribution, the incorporation of sheaf-theoretic methods. In their comments, the authors provided lengthy AI responses and also pointed to further, dense developments in their supplementary materials. I was not able to fully evaluate all of these additional materials in time to be able to vouch for the correctness of their work. Furthermore, I do not recall the other two reviewers engaging much with the sheaf theory work either, so I am concerned that one of the core components of this contribution has not received rigorous peer validation."+ },+ "createdAt": "2026-06-24T20:17:34.867Z",+ "modifiedAt": "2026-11-18T13:41:57.920Z",+ "url": "https://openreview.net/forum?id=2DhyeIm0FC¬eId=neTj9rtW7l",+ "license": "CC-BY-4.0"+}
reviews/openreview/2dhyeim0fc/notes/pdmwdqt7wy.json added
+++ b/reviews/openreview/2dhyeim0fc/notes/pdmwdqt7wy.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "PdMwDqt7WY",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer s8Yp",+ "content": {+ "summary": "This paper proposes SheafStain, a virtual staining method that translates H&E histopathology images to IHC stains (HER2, ER, PR,\nKi-67) while mitigating patch-boundary stitching artifacts. The authors states the observation that Vision Foundation Model (VFM)\nembeddings of overlapping patches yield inconsistent representations for the same spatial region termed \"context contamination\". Their\nsolution injects VFM-derived spatial conditioning (a per-position token map M and a neighborhood CLS token) into an unpaired Neural\nSchrodinger Bridge (UNSB) generator and adds two overlap-consistency regularizers, one a pixel sheaf loss and a co-cycle gluing loss.\nEvaluation at stitched 1024×1024 resolution on BCI and MIST benchmarks shows improvements in FID, KID, DISTS, Tiling Score, and\nDAB Pearson correlation over six prior methods, alongside a downstream HER2 Low/High classification task demonstrating preserved\nclinical signal.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths\n\nWell-identified practical problem, as this work addresses the central challenge that every patch-wise virtual staining pipeline faces,\nindependently generated 256×256 patches exhibit tone drift, boundary discontinuities, and chromatin-distribution mismatches when\nreassembled. The paper clearly motivates why this matters clinically and provides a concrete mechanism explaining why VFM-conditioned\ngenerators inherit this inconsistency. Rigorous empirical verification of the presheaf structure is also important and the analysis in Section 3.2 is thorough and convincing. Measuring cosine similarity across 8 strides, 4 directions, and 4,873 images with per-position breakdown in table 6 and the inverted-U pattern (figure 8), firmly establishes that the gluing axiom fails for ViT-based VFMs. The near-identical H&E/IHC gap is a particularly nice observation validating cross-stain VFM usage. In addition, evaluation protocol advancement with the decision to translate at 256×256 but evaluate at stitched 1024×1024 is a genuine methodological contribution. Prior works (pix2pix, CycleGAN, UNSB, and even D-VST's original paper) evaluate on isolated patches or resize ground truth, masking the very artifacts that determine clinical usability.\n\nWeaknesses\n\nWith very low absolute DAB-r across all methods, the best DAB Pearson correlation achieved is 0.074\n(MIST ER). Most values range from 0.02–0.05, indicating near-zero spatial correlation between predicted and ground-truth chromogen\npatterns. While SheafStain leads consistently, this means no method (including SheafStain) meaningfully localizes biomarker staining at\ncorrect cell positions. The authors partially explains this to weak pairing with consecutive sections, which is fair, but it limits claims about\nbiological coherence in the title. Secondly, the prohibitive computational cost, at ~18 seconds per 1024×1024 image , SheafStain is ~100×\nslower than PSPStain and ~430× slower than pix2pix. For gigapixel WSIs containing hundreds to thousands of such regions, this\ntranslates to hours per slide even on data-center GPUs. The authors acknowledge this, but for the clinical deployment the paper\nrepeatedly motivates, this overhead is a serious practical limitation. PSNR/SSIM inconsistency and metric cherry-picking concern.\nSheafStain does not achieve best PSNR or SSIM on any (dataset, stain) block. The authors dismiss these metrics as penalizing pixel-level\ndeviation under weak pairing, which is a reasonable argument but LPIPS and DISTS also require paired ground truth and share some of\nthis limitation. The selective emphasis on metrics where SheafStain excels, while dismissing those where it underperforms, weakens the\nevaluation's objectivity. And lastly, limited evaluation scale relative to claims as the paper's framing emphasizes WSI-level artifacts and\nclinical deployment, but validation stops at 1024×1024. The limitations section acknowledges this but the mismatch between rhetorical\nambition and experimental scale is notable. Even evaluating at 4096×4096 or 8192×8192 still far from WSI would substantially strengthen\nthe claims. And missing comparisons with closely related work. CC-WSI-Net (Liu et al., 2024) directly targets seamless WSI synthesis with\ncontent/color consistency modules and is cited but not compared against experimentally. Given that SheafStain builds on UNSB and\ntargets the same problem as CC-WSI-Net, experimental comparison with at least one of such papers would strengthen the paper.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "One thing I would like to have more clarity on is the absolute DAB r-values are very low (0.02–0.07). Was it investigated what the\ntheoretical ceiling for DAB-r might be given the consecutive-section weak pairing?",+ "limitations": "The authors discuss three limitations, first one about the validation restricted to BCI and MIST, second on the evaluation at 1024×1024 rather than full WSI scale, and last one on the unverified cross-organ generalization. These are honestly stated and each is paired with planned future work. However, the computational cost limitation is not explicitly listed here despite being arguably the most significant barrier to the clinical deployment that motivates the paper.",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "N/A",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "All my concerns were adequately addressed."+ },+ "createdAt": "2026-06-25T13:16:21.265Z",+ "modifiedAt": "2026-11-18T13:41:56.274Z",+ "url": "https://openreview.net/forum?id=2DhyeIm0FC¬eId=PdMwDqt7WY",+ "license": "CC-BY-4.0"+}
reviews/openreview/2dhyeim0fc/notes/rx3aqaim72.json added
+++ b/reviews/openreview/2dhyeim0fc/notes/rx3aqaim72.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "Rx3aQaim72",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Ri49",+ "content": {+ "summary": "This paper addresses three intertwined challenges commonly encountered in existing virtual staining methods: Weakly-paired data, Patch-wise isolation, and Reassembled-region quality degradation, identifies context contamination as the root cause of these issues, and proposes a solution named SheafStain from the perspective of sheaf theory. Extensive experimental validations are conducted in this work, with both quantitative and qualitative comparative experimental results provided to demonstrate that SheafStain can effectively resolve the aforementioned problems.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths:\n1. The paper is clearly written with a reasonable structure and detailed experimental descriptions.\n2. Sufficient experimental evaluation metrics are adopted from diverse perspectives, and the proposed method achieves a considerable performance improvement.\n3. Although SheafStain is a combination of existing theories and technologies, it is technically reasonable to apply sheaf theory to address various problems existing in patch stitching.\n4. The discussion of limitations and future work is rational.\n \nWeaknesses:\n1. The rationale for selecting the baselines is unclear.\n2. The reasons for hyperparameter selection are not elaborated.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "1. Do the three issues summarized in Figure 1 overlap? In particular, both stain-tone drift and chromatin-distribution mismatch lead to patch-boundary discontinuities.\n2. The meaning of the bolded rows in Table 1 is unclear; it is recommended to add a description of the bolded rows in the caption.\n3. Is the ground truth (GT) of the first sample of MIST in Figure 4 an incorrect image? It does not seem to match the corresponding H&E image. In addition, although the visualization demonstrates that SheafStain can eliminate artifacts such as stitching seams, a close inspection reveals certain discrepancies between its outputs and the ground truth. Therefore, how reliable are the images generated by SheafStain?\n4. Although hyperparameter settings are provided in Appendix E, what are the rationales for selecting these parameter values? How do different parameter configurations affect model performance?",+ "limitations": "yes",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "During the Rebuttal stage, the author provided detailed responses to my concerns and supplemented relevant parameter experiments and reasons for parameter settings. The author promised to include these details in the final version. Additionally, I also reviewed the comments of other reviewers and the corresponding responses from the author. Their comments were all reasonable, and there were some aspects that I had not paid attention to, such as low method efficiency and dense concepts. \n\nOverall, this paper has a very good research motivation. Using the Sheaf theory to solve the numerous problems existing in patch stitching is reasonable. The experimental evaluation perspective is diverse, the indicators are sufficient, and the effect improvement is quite significant. \n\nMaking minor modifications to the final version based on the reviewers' suggestions also helps to improve the quality of the manuscript."+ },+ "createdAt": "2026-06-23T02:02:56.189Z",+ "modifiedAt": "2026-11-18T13:41:59.365Z",+ "url": "https://openreview.net/forum?id=2DhyeIm0FC¬eId=Rx3aQaim72",+ "license": "CC-BY-4.0"+}
reviews/openreview/2dhyeim0fc/notes/vkhslbtavz.json added
+++ b/reviews/openreview/2dhyeim0fc/notes/vkhslbtavz.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "VkHsLBtAvZ",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair EU3t",+ "content": {+ "metareview": "This paper addresses virtual staining in histopathology by identifying \"context contamination\" in VFM embeddings as a source of patch-boundary inconsistencies and proposing SheafStain, which combines sheaf-theoretic consistency constraints with a Schrödinger Bridge framework to improve spatial and biological coherence in stitched outputs. Reviewers found the problem interesting, the empirical analysis of embedding inconsistency novel, and the experimental evaluation extensive, with gains over prior methods and an evaluation protocol that reflects well deployment by assessing stitched regions rather than isolated patches. However, several concerns remain. For the rebuttal, please focus on clarifying the technical role of the sheaf formulation and the Schrödinger Bridge component, and provide stronger justification for key modeling choices. Please also address the biological importance of the results given the low absolute DAB correlation values, including estimates of the ceiling under weakly paired consecutive-section data and the implications for claims of biological coherence. Additionally, discuss the impact of the method’s computational cost, justify dataset and baseline selection, explain hyperparameter choices, and reconcile the interpretation of metrics where the method underperforms."+ },+ "createdAt": "2026-07-19T14:39:16.245Z",+ "modifiedAt": "2026-11-18T15:23:15.493Z",+ "url": "https://openreview.net/forum?id=2DhyeIm0FC¬eId=VkHsLBtAvZ",+ "license": "CC-BY-4.0"+}
reviews/openreview/2dhyeim0fc/submission.json added
+++ b/reviews/openreview/2dhyeim0fc/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "2DhyeIm0FC",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 22203,+ "url": "https://openreview.net/forum?id=2DhyeIm0FC",+ "license": "CC-BY-4.0"+}
versions/v_n9a3staa.json added
+++ b/versions/v_n9a3staa.json@@ -0,0 +1,22 @@+{+ "date": "2026-05-04",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 22203,+ "url": "https://openreview.net/forum?id=2DhyeIm0FC",+ "reviews": "openreview/2dhyeim0fc",+ "evidence": [+ "https://openreview.net/forum?id=2DhyeIm0FC"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=2DhyeIm0FC",+ "evidence": [+ "https://openreview.net/forum?id=2DhyeIm0FC"+ ]+}