potentialpaper

Prototype-Aligned Multi-View Graph Learning for EHR Prediction

Update NeurIPS 2026 submission wOyvN1QBWX: 2 notes

@openreview[bot] · 2026-11-24 15:57 UTC · 07251b8644bd ·

Evidence

reviews/openreview/woyvn1qbwx/notes/rr9hpylgwn.json modified

+++ b/reviews/openreview/woyvn1qbwx/notes/rr9hpylgwn.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair 1weh",
"content": {
- "metareview": "This paper proposes MVP-EHR, which separately encodes a cohort-derived global event graph and visit-specific local graphs, aligns them through type-aware prototypes, and performs gated fusion before temporal prediction. The global/local separation is clinically intuitive, the residual design appropriately preserves local evidence, and the evaluation covers five diverse MIMIC-IV tasks. \n\nThe reviewers raised several concerns: (1) the architecture is complex, but lacks simple non-graph baselines demonstrating that GNNs, prototypes, and multiple visit graphs are necessary; (2) test-set bootstrapping does not capture training variability, while ablations use single runs and the hyperparameter-selection protocol is unclear; (3) the “global prior” is cohort-derived and may encode institutional shortcuts, while requiring local edges to appear globally may remove rare patient-specific relations; (4) temporal modeling may ignore actual inter-visit intervals; and (5) evaluation is limited to one dataset and a relatively small vocabulary, without sufficient analysis of shortcut learning, demographic/utilization confounding, prototype interpretability, or laboratory identity versus value. The presentation would also benefit from a concrete example clarifying graph construction, laboratory edge attributes, prototypes, and fusion.\n\n\nTwo concerns remain only partially resolved. First, the full MVP-EHR model is still reported as a single point estimate while the ablations now carry multi-seed statistics (qeTi's remaining request). Second, the evaluation still does not establish the regimes in which the global/local design is specifically advantageous: the diagnosis-rarity subgroup analysis is descriptive rather than a controlled perturbation of global/local signal quality, and prototype interpretability/stability across datasets and tasks remains unexamined (mQKq's main residual concern), compounded by single-dataset evaluation.\n\nOn balance, the rebuttal adds the previously missing simple/non-graph baselines, clarifies the temporal and laboratory-value handling, supplies a concrete construction example, and strengthens the ablation evidence. The residual issues bound the contribution's strength rather than undermine its validity. Reviewer scores after rebuttal are one borderline reject (primarily on complexity/readability) and two borderline accepts. I recommend Accept (poster)."
+ "metareview": "This paper proposes MVP-EHR, which separately encodes a cohort-derived global event graph and visit-specific local graphs, aligns them through type-aware prototypes, and performs gated fusion before temporal prediction. The global/local separation is clinically intuitive, the residual design appropriately preserves local evidence, and the evaluation covers five diverse MIMIC-IV tasks. \n\nThe reviewers raised several concerns: (1) the architecture is complex, but lacks simple non-graph baselines demonstrating that GNNs, prototypes, and multiple visit graphs are necessary; (2) test-set bootstrapping does not capture training variability, while ablations use single runs and the hyperparameter-selection protocol is unclear; (3) the “global prior” is cohort-derived and may encode institutional shortcuts, while requiring local edges to appear globally may remove rare patient-specific relations; (4) temporal modeling may ignore actual inter-visit intervals; and (5) evaluation is limited to one dataset and a relatively small vocabulary, without sufficient analysis of shortcut learning, demographic/utilization confounding, prototype interpretability, or laboratory identity versus value. The presentation would also benefit from a concrete example clarifying graph construction, laboratory edge attributes, prototypes, and fusion.\n\n\nTwo concerns remain only partially resolved. First, the full MVP-EHR model is still reported as a single point estimate while the ablations now carry multi-seed statistics (qeTi's remaining request). Second, the evaluation still does not establish the regimes in which the global/local design is specifically advantageous: the diagnosis-rarity subgroup analysis is descriptive rather than a controlled perturbation of global/local signal quality, and prototype interpretability/stability across datasets and tasks remains unexamined (mQKq's main residual concern), compounded by single-dataset evaluation.\n\nOn balance, the rebuttal adds the previously missing simple/non-graph baselines, clarifies the temporal and laboratory-value handling, supplies a concrete construction example, and strengthens the ablation evidence. The residual issues bound the contribution's strength rather than undermine its validity. Reviewer scores after rebuttal are one borderline reject (primarily on complexity/readability) and two borderline accepts. I recommend Accept (poster).",
+ "final_justification": "My meta-review has been updated to reflect the author response and reviewer discussion, and I recommend Accept (poster)."
},
"createdAt": "2026-07-22T06:51:52.760Z",
- "modifiedAt": "2026-11-18T15:23:24.979Z",
+ "modifiedAt": "2026-11-19T05:02:06.998Z",
"url": "https://openreview.net/forum?id=wOyvN1QBWX&noteId=RR9HpYLGWn",
"license": "CC-BY-4.0"
}

reviews/openreview/woyvn1qbwx/notes/tdrs7mtlqa.json added

+++ b/reviews/openreview/woyvn1qbwx/notes/tdrs7mtlqa.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "tDRs7MTLQa",
+ "replyTo": "9vvrBUUbmD",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer qeTi",
+ "content": {
+ "comment": "Thank you for the detailed response.\n\nThe added multi-seed ablations are useful, but this concern is only partially resolved. The full MVP-EHR model is still reported as a single point estimate, while the ablated models now have mean and standard deviation over seeds. Since the full model is the comparison point for all ablations, I would strongly encourage the authors to also report multi-seed results for MVP-EHR itself, especially for tasks where the differences between the full and reduced variants are small.\n\nHowever, overall, the rebuttal sufficiently strengthens the paper to justify increasing my original score and recommending acceptance."
+ },
+ "createdAt": "2026-08-02T16:57:24.805Z",
+ "modifiedAt": "2026-11-19T16:43:16.683Z",
+ "url": "https://openreview.net/forum?id=wOyvN1QBWX&noteId=tDRs7MTLQa",
+ "license": "CC-BY-4.0"
+}