Lifting Biomolecular Data Acquisition
Update NeurIPS 2026 submission FD6jyMD6pj: 13 notes
@openreview[bot] · 2026-11-24 15:47 UTC · 47cebdb994e7 ·
reviews/openreview/fd6jymd6pj/notes/0dgdrsljx9.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/0dgdrsljx9.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "0dgdrsLjX9",+ "replyTo": "yFvAdBtDDL",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer xUto",+ "content": {+ "comment": "Thank you for the additional experiments. Five wet-lab targets is substantial work for a rebuttal window. \n\nThe wet-lab result addresses the core of W1. Under a baseline that discards multiplets rather than splitting labels, the conventional arm still degrades from MOI 1.0 to 1.6 on all five targets, but now for a legitimate reason (data loss) rather than manufactured label noise. Confirmation of identical L1 regularisation across both arms resolves my Q1.\n\nTwo items remain open -- either would affect my final score:\n\n1. W1 for the synthetic experiments. The discard-multiplets baseline has been run on the wet-lab data but not on the synthetic data, so Figure 2 still compares against label-splitting. My original concern applies to it unchanged until the comparison is rerun.\n\n2. W2. Table 1 reports enrichment at recall 0.2 across MOI 1.0 and 1.6, while the 50-100% hit-rate claim at lines 274–277 and in the Discussion comes from PR AUC at the MOI 1.203 point in Figure 3, which still carries no quantified uncertainty. Either supply an interval at that point, or restate the claim in terms of the new results (I have no preference between them)."+ },+ "createdAt": "2026-08-01T22:52:39.118Z",+ "modifiedAt": "2026-11-19T17:10:49.732Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=0dgdrsLjX9",+ "license": "CC-BY-4.0"+}
reviews/openreview/fd6jymd6pj/notes/0nl3yr05jq.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/0nl3yr05jq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "0Nl3yr05jq",+ "replyTo": "6hF1fyKfnc",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "***“Baseline is conventional single-sequence training on split data…”***\n\nIn addition to the results on the experimental dataset reported above (Table 1), we ran a comparison to the improved baseline on the synthetic data experiments. These further confirm LIFT’s improvements:\n\n****Table 2 - LIFT performance on synthetic data.**** Performance: enrichment at recall=0.2 — i.e., the fold improvement of the model's precision at recall=0.2 over that of a random predictor. For each MOI, we report the mean and standard error across 10 independent simulations.\n\n| algorithm | MOI 1.0 | MOI 3.3 |\n|:------------|:----------|:----------|\n| LIFT | 17.2±2.6 | **33.1±7.1** |\n| baseline | 8.6±1.6 | 3.9±0.6 |"+ },+ "createdAt": "2026-08-03T13:16:25.851Z",+ "modifiedAt": "2026-11-19T17:10:49.688Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=0Nl3yr05jq",+ "license": "CC-BY-4.0"+}
reviews/openreview/fd6jymd6pj/notes/0nx0zghffx.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/0nx0zghffx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "0nx0zgHffX",+ "replyTo": "nzIWiXGuao",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for your careful reading and accurate summary. We have addressed each of the weaknesses in our response to the reviewers. Briefly:\n\n***1. Comparison to benchmark methods*** We compared LIFT to the proposed baseline, discarding multiplets. The results show consistent improvements from LIFT, on both synthetic data and on real wetlab experiments.\n\n***2. The empirical validation is somewhat narrow*** We performed additional wetlab experiments, with five more targets. We validated performance on a separate experiment, a biological replicate. The results again show consistent gains from LIFT.\n\n***3. Uncertainty quantification is missing*** We quantified our uncertainty through ten fold cross validation. The results rigorously confirm the gains from LIFT.\n\n***4. Undiscussed gap between fixed feature decision tree and a feature learning neural network.*** We strengthened our theory to reduce the gap between theory and practice, and will discuss the remaining gap clearly in the theory as well as in the limitations sections."+ },+ "createdAt": "2026-08-03T13:33:32.544Z",+ "modifiedAt": "2026-11-19T17:10:49.590Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=0nx0zgHffX",+ "license": "CC-BY-4.0"+}
reviews/openreview/fd6jymd6pj/notes/6hf1fykfnc.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/6hf1fykfnc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "6hF1fyKfnc",+ "replyTo": "ndtl1IUawD",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the careful reading, and insightful comments and questions. We have performed additional experiments and analysis. We briefly summarize the main new results, then address each comment and question point-by-point.\n\nWe performed additional laboratory experiments following the same protocol, with more pHLA targets and increased MOI. We trained models using LIFT and a stronger baseline, where cells with more than one sequence ($m_i > 1$) are discarded. We evaluated at MOI=1, where the baseline is expected to perform best, and at higher MOI. We tested models’ performance on datapoints with $m_i=1$ that were taken from a separate validation screen, i.e. a biological replicate. We used 10-fold cross validation to quantify uncertainty. The results show consistent improvement from LIFT across targets, with the best performance coming from the LIFT model at high MOI. EDIT: NOTE THE RESULTS ARE UPDATED WITH ADDITIONAL DATA SINCE OUR FIRST COMMENT\n\n****Table 1 - LIFT performance on laboratory TCRm experiments****\nPerformance: enrichment at recall=0.2 — i.e., the fold improvement of the model's precision at recall=0.2 over that of a random predictor. For each MOI, we report the mean and standard deviation across 10-fold cross validation. \n| target | algorithm | MOI 0.3 | MOI 1.0 | MOI 1.6 |\n|:---------|:-------------|:----------|:----------|:----------|\n| pHLA #1 | LIFT | 1.5±0.5 | 3.2±1.1 | **3.5±1.0** |\n| pHLA #1 | baseline | 1.5±0.5 | 1.9±0.5 | 1.5±0.8 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #2 | LIFT | 7.8±4.1 | 18.4±6.4 | **24.1±5.4** |\n| pHLA #2 | baseline | 4.6±3.1 | 9.2±3.4 | 8.8±5.4 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #3 | LIFT | 5.3±3.0 | 10.7±3.7 | **16.7±4.3** |\n| pHLA #3 | baseline | 3.7±2.3 | 6.1±2.8 | 4.7±1.9 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #4 | LIFT | 6.2±3.6 | 17.9±2.9 | **18.9±4.2** |\n| pHLA #4 | baseline | 6.0±2.6 | 5.8±2.5 | 4.2±1.8 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #5 | LIFT | 1.6±0.5 | 2.3±0.5 | **2.6±0.5** |\n| pHLA #5 | baseline | 1.2±0.2 | 1.6±0.4 | 1.2±0.2 |\n\n\n\n***\"Baseline is conventional ... Please consider adding further (stronger) baselines\"***\nThank you for raising this important point. Our new results add a stronger baseline. Reviewer xUto explained how splitting a datapoint $((x_{i1}, x_{i2}, \\ldots), y_i)$ into $(x_{i1}, y), (x_{i1}, y), \\ldots$ can introduce label noise. Our new results (Table 1) compare to the stronger alternative they suggest, discarding cells with $m_i > 1$. We will also add this baseline to the synthetic data experiments.\n\nThe pooled-screening methods cited are fundamentally limited in their scalability, tractability and generalization. Experimentally, they require synthesizing sequences individually rather than stochastically via variational synthesis, and then pooling these sequences in defined combinations. This means they are limited to testing far fewer $x$ values, and require specialized liquid handling. For inference, they train models that make predictions only about observed sequences, so they would exhibit no predictive performance on our evaluations. Our revision will discuss these limitations, and add a synthetic data experiment demonstrating the limitations of the experimental design, even when learning using our neural network method.\n\n\n***\"The real-data MOI trend...\"***\nThank you for pointing out this concern. We performed new experiments and analysis across 5 pHLA targets, beyond MAGE-A4, quantified uncertainty with cross validation, and evaluated predictive performance on data from a separate experiment (Table 1). Though absolute performance is low, the biological significance is substantial: TCRms have been sought as potential therapeutics for decades, but only a few have been found after testing billions of sequences; now we have predictive performance that translates directly into higher discovery rates. \n\n***\"Can you isolate the method effect...\"***\nThank you for raising this point. Our experiments control for data quantity when we compare different methods: we train LIFT and the baseline on the same number of cells, across every MOI. This comes from a careful subsampling procedure, which matches the number of cells in the subsampled data to the number of cells in the high MOI training dataset (App. E). Our revision will carefully clarify this point.\n\nNote crucially that we define the “size” of a dataset as the number of cells that are measured, since this is the key biological constraint. Some of these cells have no $x$ ($m_i = 0$) simply by chance, but that does not reduce the cost of growing the cell, measuring its activity, and sequencing to look for the $x$. \n\n****Response is continued in the next comment****"+ },+ "createdAt": "2026-07-29T10:48:37.056Z",+ "modifiedAt": "2026-11-19T17:10:49.963Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=6hF1fyKfnc",+ "license": "CC-BY-4.0"+}
reviews/openreview/fd6jymd6pj/notes/abpy4gss0d.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/abpy4gss0d.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "ABPy4GsS0D",+ "replyTo": "0k2SJc2pg6",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the careful reading, and insightful comments and questions. \n\n***“W1 - The theory does not cover the method's main novelty…. Limitations: the theory covers a simplified version rather than the neural method that is the central claim\"***\n\nThank you for raising this important point, indeed there is a gap between the simplified theoretical model (linear) and the actual experiments (feature learning neural networks). We will clearly discuss this gap in our revision, and explain that the full method is only demonstrated, not proven.\n\nTo begin to close the gap, we extended our theory. Applying results from Naderi & Plan (2022), we can show our method achieves efficient inference when $w_d$ in Eqn. 8 is parameterized by a neural network, $w_d(\\theta) = NN(\\theta, V_d)$, rather than linear. The caveat is that they assume Gaussian measurements, while biologically only Poisson measurements are tractable, and a Gaussian approximation is only valid in the limit of large MOI. They also deal with finite parameter models, rather than studying the infinite parameter feature learning limit. These limitations stem from the compressed sensing theory currently available: a framework that is general enough to handle both Poisson measurements and neural networks (in the way we use them) has not been developed - though it does not seem implausible, just complex. We will discuss these limitations clearly in the theory and discussion sections of our revision.\n\nNaderi, A. and Plan, Y. Sparsity-Free Compressed Sensing With Applications to Generative Priors. IEEE Journal on Selected Areas in Information Theory (2022).\n\n***“W2: The empirical validation is somewhat narrow… Limitations: the wet-lab evidence rests on a single target…\"***\n\nWe performed additional laboratory experiments following the same protocol, with more pHLA targets and increased MOI. We trained models using LIFT and a stronger baseline, where cells with more than one sequence ($m_i > 1$) are discarded. We evaluated at MOI=1, where the baseline is expected to perform best, and at higher MOI. We tested models’ performance on datapoints with $m_i=1$ that were taken from a separate validation screen, i.e. a biological replicate. We used 10-fold cross validation to quantify uncertainty. The results show consistent improvement from LIFT across targets, with the best performance coming from the LIFT model at high MOI. EDIT: NOTE THE RESULTS ARE UPDATED WITH ADDITIONAL DATA SINCE OUR FIRST COMMENT\n\n****Table 1 - LIFT performance on laboratory TCRm experiments****\nPerformance: enrichment at recall=0.2 — i.e., the fold improvement of the model's precision at recall=0.2 over that of a random predictor. For each MOI, we report the mean and standard deviation across 10-fold cross validation. \n| target | algorithm | MOI 0.3 | MOI 1.0 | MOI 1.6 |\n|:---------|:-------------|:----------|:----------|:----------|\n| pHLA #1 | LIFT | 1.5±0.5 | 3.2±1.1 | **3.5±1.0** |\n| pHLA #1 | baseline | 1.5±0.5 | 1.9±0.5 | 1.5±0.8 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #2 | LIFT | 7.8±4.1 | 18.4±6.4 | **24.1±5.4** |\n| pHLA #2 | baseline | 4.6±3.1 | 9.2±3.4 | 8.8±5.4 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #3 | LIFT | 5.3±3.0 | 10.7±3.7 | **16.7±4.3** |\n| pHLA #3 | baseline | 3.7±2.3 | 6.1±2.8 | 4.7±1.9 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #4 | LIFT | 6.2±3.6 | 17.9±2.9 | **18.9±4.2** |\n| pHLA #4 | baseline | 6.0±2.6 | 5.8±2.5 | 4.2±1.8 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #5 | LIFT | 1.6±0.5 | 2.3±0.5 | **2.6±0.5** |\n| pHLA #5 | baseline | 1.2±0.2 | 1.6±0.4 | 1.2±0.2 |\n\n\n\n\nIn these evaluations, we subsampled the full dataset to evaluate different MOI. This provides a controlled internal comparison: there is no screen-to-screen biological variation. It is also much more feasible (large scale screens of this kind produce large amounts of data, but they are expensive and time consuming). But it does mean our comparison relies on the assumption that the subsampled data is representative of lower MOI. Our revision will clearly explain the motivation for this assumption, namely that the number of sequences delivered into a cell is independent across cells. This independence assumption is justified by previous observations in the literature, and the fact that there are a very large number of cells and sequences in our experiments (millions), which are well mixed physically. This suggests the distribution should be exchangeable and very close to iid conditional on the MOI [Diaconis and Freedman 1980].\n\nDiaconis, P. and Freedman, D. Finite Exchangeable Sequences. Annals of Probability (1980)."+ },+ "createdAt": "2026-07-29T11:01:45.022Z",+ "modifiedAt": "2026-11-19T17:10:49.793Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=ABPy4GsS0D",+ "license": "CC-BY-4.0"+}
reviews/openreview/fd6jymd6pj/notes/bpkgc9mkme.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/bpkgc9mkme.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "BPKGc9MKME",+ "replyTo": "ABPy4GsS0D",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you again for the thoughtful review. Note that we updated our response with more extensive data, since our initial reply. Please let us know if you have any more comments and questions."+ },+ "createdAt": "2026-08-03T13:37:33.498Z",+ "modifiedAt": "2026-11-19T17:10:49.561Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=BPKGc9MKME",+ "license": "CC-BY-4.0"+}
reviews/openreview/fd6jymd6pj/notes/bsnxaxmpje.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/bsnxaxmpje.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "BSNXaXmPJE",+ "replyTo": "yFvAdBtDDL",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "***“3. Is the uniform-partition assumption a genuine restriction?...”***\n\n\nThank you for this suggestion, we agree and will add a sentence on how to think about D and the partition. The uniform partition assumption is a genuine restriction because:\n1. It is often advantageous in practice to use non-uniform libraries where $p(x)$ has higher values on $x$ that are more likely to be active, e.g. in our laboratory experiments we control $p(x)$ to match a generative antibody model.\n2. Even if we can make the partition finer, this has consequences: larger $D$ suggests we can (1) expect worse estimation error, and (2) should use higher MOI (Prop. 5.5). \n\nIn short, the uniform partition assumption is a simplification of reality, which we use to build understanding of the method."+ },+ "createdAt": "2026-07-31T23:15:40.606Z",+ "modifiedAt": "2026-11-19T17:10:49.705Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=BSNXaXmPJE",+ "license": "CC-BY-4.0"+}
reviews/openreview/fd6jymd6pj/notes/jlaxsx41pc.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/jlaxsx41pc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "jLAXsx41pC",+ "replyTo": "6hF1fyKfnc",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "***“Theory proves the efficiency result… Can you say anything about how the coherence result behaves...”***\nThank you for raising this important point, indeed there is a gap between the simplified theoretical model (fixed-feature decision tree) and the actual experiments (feature learning neural networks). We will clearly discuss this gap in our revision.\n \nTo begin to close the gap, we extended our theory. Applying results from Naderi & Plan (2022), we can show our method achieves efficient inference when $w_d$ in Eqn. 8 is parameterized by a neural network, $w_d(\\theta) = NN(\\theta, V_d)$, rather than linear. The caveat is that they assume Gaussian measurements, while biologically only Poisson measurements are tractable, and a Gaussian approximation is only valid in the limit of large MOI. They also deal with finite parameter models, rather than studying the infinite parameter feature learning limit. These limitations stem from the compressed sensing theory currently available: a framework that is general enough to handle both Poisson measurements and neural networks (in the way we use them) has not yet been developed. We will discuss these limitations clearly in the theory and discussion sections of our revision.\n\nNaderi, A. and Plan, Y. Sparsity-Free Compressed Sensing With Applications to Generative Priors. IEEE Journal on Selected Areas in Information Theory. 3(3) 2022."+ },+ "createdAt": "2026-07-29T10:52:37.964Z",+ "modifiedAt": "2026-11-19T17:10:49.961Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=jLAXsx41pC",+ "license": "CC-BY-4.0"+}
reviews/openreview/fd6jymd6pj/notes/k9v3wngqgg.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/k9v3wngqgg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "k9V3WNgQgG",+ "replyTo": "yFvAdBtDDL",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for your thoughtful response and continued engagement. We have addressed both open items:\n\n1. We ran a comparison to the discard-multiplet baseline on the synthetic data. The results confirm LIFT’s improvement. We will update Figure 2 with this baseline in our revision. \n\n****Table 2 - LIFT performance on synthetic data.**** Performance: enrichment at recall=0.2 — i.e., the fold improvement of the model's precision at recall=0.2 over that of a random predictor. For each MOI, we report the mean and standard error across 10 independent simulations.\n\n| algorithm | MOI 1.0 | MOI 3.3 |\n|:------------|:----------|:----------|\n| LIFT | 17.2±2.6 | **33.1±7.1** |\n| baseline | 8.6±1.6 | 3.9±0.6 |\n\n2. We will restate the claim in terms of the new results, which show LIFT provides a 70%-280% improvement across targets versus the discard-multiplet baseline."+ },+ "createdAt": "2026-08-03T13:14:56.009Z",+ "modifiedAt": "2026-11-19T17:10:49.732Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=k9V3WNgQgG",+ "license": "CC-BY-4.0"+}
reviews/openreview/fd6jymd6pj/notes/nziwixguao.json modified
+++ b/reviews/openreview/fd6jymd6pj/notes/nziwixguao.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair Lbg3","content": {- "metareview": "This paper proposes increasing information density in wet-lab science by measuring multiple molecules' activity simultaneously (rather than one at a time) and using a neural extension of compressed sensing to function space to deconvolute the molecule-activity map during model training.\n\nStrength:\n\n* The problem studied in the paper is important and interesting\n* The paper is well-written \n* The paper includes results from real wet-lab experiments. This is beyond the scope of most NeurIPS submissions and is appreciated.\n* Honest limitations section \n\nWeaknesses:\n* The reviewers raised concerns about comparison to benchmark methods:\n\"An honest comparison would therefore compare LIFT against a conventional pipeline that discards multiplets, instead of the label-splitting scheme\"\n* The empirical validation is somewhat narrow: \"The wet-lab demonstration is on a single target with modest absolute performance, and the comparison across mixture sizes is largely obtained by subsampling one dataset rather than by running separate experiments. A second target or more direct evidence would make the practical case considerably stronger.\"\n* Uncertainty quantification is missing\n* \"The theory proves the efficiency result for a fixed-feature decision-tree reduction, while the method and all experiments use a feature-learning CNN. The gap seems to be undiscussed.\""+ "metareview": "This paper proposes increasing information density in wet-lab science by measuring multiple molecules' activity simultaneously (rather than one at a time) and using a neural extension of compressed sensing to function space to deconvolute the molecule-activity map during model training.\n\nStrength:\n\n* The problem studied in the paper is important and interesting\n* The paper is well-written \n* The paper includes results from real wet-lab experiments. This is beyond the scope of most NeurIPS submissions and is appreciated.\n* Honest limitations section \n\nWeaknesses:\n* The reviewers raised concerns about comparison to benchmark methods:\n\"An honest comparison would therefore compare LIFT against a conventional pipeline that discards multiplets, instead of the label-splitting scheme\"\n* The empirical validation is somewhat narrow: \"The wet-lab demonstration is on a single target with modest absolute performance, and the comparison across mixture sizes is largely obtained by subsampling one dataset rather than by running separate experiments. A second target or more direct evidence would make the practical case considerably stronger.\"\n* Uncertainty quantification is missing\n* \"The theory proves the efficiency result for a fixed-feature decision-tree reduction, while the method and all experiments use a feature-learning CNN. The gap seems to be undiscussed.\"",+ "final_justification": "After the rebuttal, reviewers increased their scores."},"createdAt": "2026-07-23T06:12:50.987Z",- "modifiedAt": "2026-11-18T15:23:34.221Z",+ "modifiedAt": "2026-11-19T05:02:13.486Z","url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=nzIWiXGuao","license": "CC-BY-4.0"}
reviews/openreview/fd6jymd6pj/notes/umtehppozf.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/umtehppozf.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "umteHPpOZf",+ "replyTo": "0Nl3yr05jq",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you again for the thoughtful review. Note that we also updated our response with more extensive data, since our initial reply. Please let us know if you have any more comments and questions."+ },+ "createdAt": "2026-08-03T13:38:21.216Z",+ "modifiedAt": "2026-11-19T17:10:49.519Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=umteHPpOZf",+ "license": "CC-BY-4.0"+}
reviews/openreview/fd6jymd6pj/notes/uqdjldnzkt.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/uqdjldnzkt.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "uQdjLDnzkT",+ "replyTo": "k9V3WNgQgG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer xUto",+ "content": {+ "comment": "Thank you, this resolves both open items. I am raising my rating accordingly."+ },+ "createdAt": "2026-08-03T13:20:34.175Z",+ "modifiedAt": "2026-11-19T17:10:49.612Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=uQdjLDnzkT",+ "license": "CC-BY-4.0"+}
reviews/openreview/fd6jymd6pj/notes/yfvadbtddl.json added
+++ b/reviews/openreview/fd6jymd6pj/notes/yfvadbtddl.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "yFvAdBtDDL",+ "replyTo": "UDPRzobgJD",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the careful reading, and insightful comments and questions. We have performed additional experiments and analysis. We briefly summarize the main new results, then address each comment and question point-by-point.\n\nWe performed additional laboratory experiments following the same protocol, with more pHLA targets and increased MOI. We trained models using LIFT and a stronger baseline, where cells with more than one sequence ($m_i > 1$) are discarded. We evaluated at MOI=1, where the baseline is expected to perform best, and at higher MOI. We tested models’ performance on datapoints with $m_i=1$ that were taken from a separate validation screen, i.e. a biological replicate. We used 10-fold cross validation to quantify uncertainty. The results show consistent improvement from LIFT across targets, with the best performance coming from the LIFT model at high MOI. EDIT: NOTE THE RESULTS ARE UPDATED WITH ADDITIONAL DATA SINCE OUR FIRST COMMENT\n\n****Table 1 - LIFT performance on laboratory TCRm experiments****\nPerformance: enrichment at recall=0.2 — i.e., the fold improvement of the model's precision at recall=0.2 over that of a random predictor. For each MOI, we report the mean and standard deviation across 10-fold cross validation. \n\n| target | algorithm | MOI 0.3 | MOI 1.0 | MOI 1.6 |\n|:---------|:-------------|:----------|:----------|:----------|\n| pHLA #1 | LIFT | 1.5±0.5 | 3.2±1.1 | **3.5±1.0** |\n| pHLA #1 | baseline | 1.5±0.5 | 1.9±0.5 | 1.5±0.8 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #2 | LIFT | 7.8±4.1 | 18.4±6.4 | **24.1±5.4** |\n| pHLA #2 | baseline | 4.6±3.1 | 9.2±3.4 | 8.8±5.4 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #3 | LIFT | 5.3±3.0 | 10.7±3.7 | **16.7±4.3** |\n| pHLA #3 | baseline | 3.7±2.3 | 6.1±2.8 | 4.7±1.9 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #4 | LIFT | 6.2±3.6 | 17.9±2.9 | **18.9±4.2** |\n| pHLA #4 | baseline | 6.0±2.6 | 5.8±2.5 | 4.2±1.8 |\n| -------- | ------------ | --------- | --------- | --------- |\n| pHLA #5 | LIFT | 1.6±0.5 | 2.3±0.5 | **2.6±0.5** |\n| pHLA #5 | baseline | 1.2±0.2 | 1.6±0.4 | 1.2±0.2 |\n\n\n***“The conventional baseline is fed labels…”***\nThank you for pointing out this limitation. We reran our analysis, using a pipeline that discards cells with $m_i > 1$. The results (Table 1) are in line with your intuition: discarding $m_i > 1$ produces stronger performance than splitting a datapoint $((x_{i1}, x_{i2}, \\ldots), y_i)$ into $(x_{i1}, y), (x_{i1}, y), \\ldots$, but still underperforms LIFT. We will also run this baseline on the synthetic data experiments.\n\n***“The headline wet-lab result rests on a single point...”***\nThank you for pointing out this concern. We have repeated our experiments and analysis across 5 pHLA targets, beyond MAGE-A4, and evaluated external validity on a biological replicate (Table 1). We used 10-fold cross validation to quantify uncertainty (Table 1). The results show consistent improvement from LIFT.\n\n***\"1. Does the conventional baseline receive the L1 / sparsity penalty? …”***\nThank you for raising this - yes, we applied identical regularization to the baseline, including for Table 1. We will state this explicitly in our revision.\n\n***“2. Why was the wet-lab validation confined to MOI = 1.2 …? …”***\nThank you, we agree this is an important limitation, and will discuss clearly the limitations of our wet lab study. Our new wetlab study uses an MOI of 1.6. We used MOIs near 1 for these initial studies to establish the method’s feasibility, rather than to identify its outer limits:\n1. It enables a controlled internal comparison, where we have enough cells with $m_i = 1$ to reliably compare to a conventional baseline using data from the same screen. \n2. It is meaningfully higher (5x) than conventional MOIs that are set to ensure only a small population of doublets, e.g. our own standard protocol previously targeted MOI = 0.3. \n3. Practically, producing high titre lentivirus is challenging, and we do not know the MOI at which we reach toxicity; an MOI modestly above 1 was a conservative choice.\n\nSince the initial submission, we have successfully established a protocol for achieving higher effective MOI by loading multiple cells into the same droplet (reaching as many as 9-10 cells per droplet), and will have the results of the full screening study in time to add them to the camera ready revision."+ },+ "createdAt": "2026-07-29T10:33:05.848Z",+ "modifiedAt": "2026-11-19T17:10:49.843Z",+ "url": "https://openreview.net/forum?id=FD6jyMD6pj¬eId=yFvAdBtDDL",+ "license": "CC-BY-4.0"+}