Calibrated Target Noise Recovers Curvature from the Gradients

Update NeurIPS 2026 submission DVmkA0zr2U: 5 notes

@openreview[bot] · 2026-11-24 15:47 UTC · 279dd5fff656 ·

Evidence

reviews/openreview/dvmka0zr2u/notes/8npoxnsmlf.json added

+++ b/reviews/openreview/dvmka0zr2u/notes/8npoxnsmlf.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "8NPOxNSmlf",
+ "replyTo": "aF8URiIhz0",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q4: Computational overhead (Q3 of AC), continued",
+ "comment": "**Q4: Computational overhead (Q3 of AC), continued**\nTo complement the discussion above, we report end-to-end wall-clock time for the optimization experiments from Figure 3. Table R2 shows the time required to reach within 10% of the best test loss achieved in the corresponding experiment. Results are averaged over 10 random seeds, with one standard deviation. Methods marked with `^` did not reach the threshold within the allotted training budget; for these, we report the full elapsed training time.\n\n\n*Table R2: Wall-clock time to reach the test-loss threshold.* The best result is highlighted in bold and the second best is in italic.\n\n| Optimizer | mlp, telescope | cnn, occupancy | cnn, air | transf, occupancy | transf, air |\n| --------------- | --------------- | --------------- | --------------- | ----------------- | ---------------- |\n| GD | 22.29 ± 0.23^ | 8.36 ± 0.11^ | 18.22 ± 0.35^ | 77.08 ± 0.66^ | 181.03 ± 2.00^ |\n| Adam | 16.02 ± 0.17 | *3.81 ± 0.05* | 20.34 ± 0.22^ | 44.71 ± 0.66 | 169.94 ± 2.04 |\n| Sophia | 7.62 ± 0.09 | 4.10 ± 0.04 | 16.78 ± 0.28 | 44.37 ± 0.56 | 96.71 ± 0.76 |\n| Sophia C (ours) | *7.42 ± 0.11* | 4.12 ± 0.05 | *12.00 ± 0.14* | *39.90 ± 0.38* | *86.46 ± 0.92* |\n| GD, PC (ours) | **1.65 ± 0.02** | **0.96 ± 0.02** | **2.60 ± 0.02** | **10.01 ± 0.11** | **16.32 ± 0.16** |\n\nThese results indicate that, in the optimization experiments reported in the paper, the faster convergence obtained from the proposed curvature-based preconditioning compensates for the additional computation introduced by the curvature probe and preconditioner update. The diagonal variant of our preconditioner, Sophia C, has the same scalable diagonal-preconditioning structure as Sophia, but uses our CNGC curvature estimate. Under this setup, Sophia C reaches the threshold slightly faster than Sophia across the reported tasks and is scalable to large models due to the diagonal preconditioner.\n\nThe experimental setup is identical to Figure 3 in the main text. The test-loss thresholds used were: MLP Telescope 0.3402; CNN Occupancy 0.1701; CNN Air 0.4804; Transformer Occupancy 0.1767; Transformer Air 0.2526."
+ },
+ "createdAt": "2026-07-29T07:02:36.478Z",
+ "modifiedAt": "2026-11-19T17:11:54.911Z",
+ "url": "https://openreview.net/forum?id=DVmkA0zr2U&noteId=8NPOxNSmlf",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/dvmka0zr2u/notes/pdd4b1l0cl.json added

+++ b/reviews/openreview/dvmka0zr2u/notes/pdd4b1l0cl.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "pDd4b1L0CL",
+ "replyTo": "wIgvb6ID0Z",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Meta Review Rebuttal",
+ "comment": "We thank the Area Chair for their Meta Review.\n\nWe have addressed each point of the Meta Review. We have also added several new experiments as tables. You can find these in our rebuttal and general comments to **Reviewer r2pN** (the replies are marked with the corresponding question numbers in MetaReview).\n\nA summary of the new experiments:  **Table R1** reports wall-clock time per epoch , **Table R2** compares optimization wall-clock time needed to reach an accuracy threshold, **Tables R3 and R4** present the CNGC-versus-exact-GGN ablation, and **Table R5** evaluates early stopping application of the estimator with added validation set comparison.\n\nOur paper's main contribution is a principled recovery of GGN from aggregated first-order gradients with added noise, proven to be optimal for the recovery. Our method is very general and can be used in many down-stream applications, such as optimization and early stopping.\n\nFor optimization, **Table R2** shows that GD, PC (ours) requires less optimization wall-clock time than Sophia and Adam. Moreover, our scalable Sophia variant, SophiaC (which only replaces Sophia's GNB estimator with our CNGC estimator) outperforms both Sophia and Adam. Moreover, SophiaC optimizer uses only a diagonal of the GGN for the preconditioning, thus it is highly scalable.\n\nThis advantage is theoretically grounded: Proposition 3.3 (Optimality of Scaled Rademacher Noise) establishes the optimality of our noise construction for the family of additive noises. While Sophia's GNB estimator has a different form from CNGC (ours), we can still prove our estimator has smaller expected estimation error. We provide the detailed comparison below\n\n**CNGC has lower expected error than Sophia's GNB in estimating GGN:**\n\n**Regression.** For a mini-batch of inputs $x_1,\\ldots,x_n$, Sophia's curvature probe samples $\\hat y_i=f_w(x_i)+\\epsilon_i$ with $\\epsilon_i\\sim N(0,1)$ and computes $\\hat g=\\nabla_w[1/(2n)\\sum_i(f_w(x_i)-\\hat y_i)^2]=-1/n\\sum_i\\epsilon_i\\nabla_w f_w(x_i)$, returning the GNB estimator $G=n\\hat g\\odot\\hat g=\\bar g\\odot\\bar g$. This is equivalent to our centered estimator $\\bar g=\\sqrt n\\hat g=1/n\\sum_i\\xi_i\\nabla_w f_w(x_i)$ with admissible centered noise $\\xi_i=-\\sqrt n\\epsilon_i\\sim N(0,n)$. By Proposition 3.3 (Optimality of Scaled Rademacher Noise), this Gaussian noise is suboptimal and yields a larger expected estimation error than scaled Rademacher noise (ours).\n\n**Binary Classification.** For a mini-batch of inputs $x_1,\\ldots,x_n$, Sophia's curvature probe samples $\\hat y_i\\sim Bernoulli(p_i)$, where $p_i=\\sigma(f_w(x_i))$, and computes the binary cross-entropy gradient $\\hat g=\\nabla_w[1/n\\sum_i L(f_w(x_i),\\hat y_i)]=1/n\\sum_i(p_i-\\hat y_i)\\nabla_w f_w(x_i)$, returning the GNB estimator $n\\hat g\\odot\\hat g$. This is equivalent to our centered estimator $\\bar g\\odot\\bar g$ with $\\bar g=\\sqrt n\\hat g=1/n\\sum_i\\xi_i\\nabla_w f_w(x_i)$ that uses admissible centered noise $\\xi_i=\\sqrt n(\\hat y_i - p_i)$, since $E[\\xi_i|x_i]=0$. By Proposition 3.3 (Optimality of Scaled Rademacher Noise), any admissible noise (including Sophia's Bernoulli-induced noise) has larger (or equal) expected estimation error than scaled Rademacher noise. A direct calculation shows that equality holds only when $p_i=0$, $p_i=1/2$, or $p_i=1$ for all i, while the inequality is strict for all other values of $p$. Hence, Sophia's GNB curvature estimator is also suboptimal for binary classification, while our scaled Rademacher noise is optimal.\n\nThese two observations are following from Proposition~3.3 (Optimality of Scaled Rademacher Noise) and we will add more explanations in the final version."
+ },
+ "createdAt": "2026-07-31T13:59:07.079Z",
+ "modifiedAt": "2026-11-19T17:11:54.722Z",
+ "url": "https://openreview.net/forum?id=DVmkA0zr2U&noteId=pDd4b1L0CL",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/dvmka0zr2u/notes/wigvb6id0z.json modified

+++ b/reviews/openreview/dvmka0zr2u/notes/wigvb6id0z.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair oFqW",
"content": {
- "metareview": "UPDATE: \nThe most critical reviewer, r2pn, appear convinced by the rebuttal has has raised their score to acceptance from 2 to 4. The authors have put good effort to responding to the questions and at this point I believe that the submission should be accepted.\n\nORIGINAL METAREVIEW: \n\nRatings span accept to reject (5, 4, 2), and confidence varies substantially (4, 1, 3), so I’m weighting the more technically specific reviews more heavily in this synthesis, particularly r2pN. I would treat the current state of acceptance as borderline, but a good rebuttal with thoughtful responses to these raised issues could push the paper to acceptenace:\n1. The relationship between curvature-recovery accuracy and the observed downstream gains (faster optimization, useful early stopping) is not disentangled. It’s unclear whether improvements stem from accurate GGN recovery specifically, or from optimization dynamics/implicit regularization introduced by the injected noise itself. This needs to be addressed directly, since it bears on what the method’s contribution actually is.\n2. The method’s scope is restricted to GLM/exponential-family-style losses. The paper should clarify how far this generalizes beyond the demonstrated settings, and be explicit about what modern training losses would require modification or fall outside the framework.\n3. Experimental validation is limited to small-scale models and datasets, with no large-scale benchmark (e.g., ImageNet-scale or LLM-pretraining settings) to establish scalability, stability, or wall-clock trade-offs, and full wall-clock/overhead accounting for the preconditioning pipeline (extra backward pass, curvature accumulation, blockwise storage, matrix inversion) is not provided.\n4. The early-stopping evaluation relies on a non-standard, approximated GradStop-type statistic rather than standard validation-loss early stopping, and sensitivity to this approximation is not characterized.\nNon-critical: sparser items like more explicit multi-class formulas with a supporting experiment, and stronger second-order preconditioning baselines (K-FAC, Shampoo-type methods), would strengthen the paper but are reasonable follow-up rather than blocking.\n\nI’d frame this as conditional rather than leaning either direction: if the authors can clarify the novelty relative to prior target-noise curvature recovery for linear regression, disentangle the source of the empirical gains, and provide a fuller cost accounting, that would meaningfully address the split in reviewer assessments. Please flag if any of this reflects a misreading of the paper’s claimed contribution."
+ "metareview": "UPDATE: \nThe most critical reviewer, r2pn, appear convinced by the rebuttal has has raised their score to acceptance from 2 to 4. The authors have put good effort to responding to the questions and at this point I believe that the submission should be accepted.\n\nORIGINAL METAREVIEW: \n\nRatings span accept to reject (5, 4, 2), and confidence varies substantially (4, 1, 3), so I’m weighting the more technically specific reviews more heavily in this synthesis, particularly r2pN. I would treat the current state of acceptance as borderline, but a good rebuttal with thoughtful responses to these raised issues could push the paper to acceptenace:\n1. The relationship between curvature-recovery accuracy and the observed downstream gains (faster optimization, useful early stopping) is not disentangled. It’s unclear whether improvements stem from accurate GGN recovery specifically, or from optimization dynamics/implicit regularization introduced by the injected noise itself. This needs to be addressed directly, since it bears on what the method’s contribution actually is.\n2. The method’s scope is restricted to GLM/exponential-family-style losses. The paper should clarify how far this generalizes beyond the demonstrated settings, and be explicit about what modern training losses would require modification or fall outside the framework.\n3. Experimental validation is limited to small-scale models and datasets, with no large-scale benchmark (e.g., ImageNet-scale or LLM-pretraining settings) to establish scalability, stability, or wall-clock trade-offs, and full wall-clock/overhead accounting for the preconditioning pipeline (extra backward pass, curvature accumulation, blockwise storage, matrix inversion) is not provided.\n4. The early-stopping evaluation relies on a non-standard, approximated GradStop-type statistic rather than standard validation-loss early stopping, and sensitivity to this approximation is not characterized.\nNon-critical: sparser items like more explicit multi-class formulas with a supporting experiment, and stronger second-order preconditioning baselines (K-FAC, Shampoo-type methods), would strengthen the paper but are reasonable follow-up rather than blocking.\n\nI’d frame this as conditional rather than leaning either direction: if the authors can clarify the novelty relative to prior target-noise curvature recovery for linear regression, disentangle the source of the empirical gains, and provide a fuller cost accounting, that would meaningfully address the split in reviewer assessments. Please flag if any of this reflects a misreading of the paper’s claimed contribution.",
+ "final_justification": "The most critical reviewer, r2pn, appear convinced by the rebuttal has has raised their score to acceptance from 2 to 4. The authors have put good effort to responding to the questions and at this point I believe that the submission should be accepted."
},
"createdAt": "2026-07-24T11:54:54.643Z",
- "modifiedAt": "2026-11-18T15:23:35.128Z",
+ "modifiedAt": "2026-11-19T05:02:14.674Z",
"url": "https://openreview.net/forum?id=DVmkA0zr2U&noteId=wIgvb6ID0Z",
"license": "CC-BY-4.0"
}

reviews/openreview/dvmka0zr2u/notes/xq5sonlhfp.json added

+++ b/reviews/openreview/dvmka0zr2u/notes/xq5sonlhfp.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "xq5sOnlHfp",
+ "replyTo": "aF8URiIhz0",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q7: Early stopping (Q4 of AC) and Q1: Practical value of the GGN, continued",
+ "comment": "**Q7: Early stopping (Q4 of AC)** and **Q1: Practical value of the GGN, continued.** We compare three early-stopping methods: GradStop, GradStop based on our cheap GGN estimate (ours), and standard validation-loss stopping. The validation baseline uses a 90/10 training–validation split, whereas our method and GradStop use the full training set without a validation split. All three methods stop after their criterion increase for three consecutive evaluations (patience 3). Both GradStop and ours use the diagonal blocks of GGN instead of the full matrix (so it is directly reused from the optimization, no extra computations are needed).\n\nAll results are averaged across 10 seeds with one standard deviation.\n\n\n*Table R5: Test loss for early stopping method and model-dataset combination with patience 3:*\n\n| Optimizer | mlp_telescope | cnn_occupancy | cnn_air | transf_occupancy | transf_air |\n| --- | --- | --- | --- | --- | --- |\n| ours | 0.3075 ± 0.0034 | 0.1279 ± 0.0127 | 0.4647 ± 0.0234 | 0.1223 ± 0.0580 | 0.1843 ± 0.0271 |\n| GradStop | 0.3056 ± 0.0039 | 0.1350 ± 0.0196 | 0.4799 ± 0.0419 | 0.1227 ± 0.0610 | 0.2411 ± 0.1246 |\n| val | 0.3061 ± 0.0039 | 0.1273 ± 0.0197 | 0.5223 ± 0.2019 | 0.1078 ± 0.0137 | 0.1646 ± 0.0096 |\n\nOur contribution is an inexpensive, theoretically principled GGN approximation that can support multiple downstream applications. Early stopping is one such demonstration: our method is competitive with standard validation-based stopping without requiring a validation split, and improves upon GradStop."
+ },
+ "createdAt": "2026-07-31T08:20:25.399Z",
+ "modifiedAt": "2026-11-19T17:11:54.725Z",
+ "url": "https://openreview.net/forum?id=DVmkA0zr2U&noteId=xq5sOnlHfp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/dvmka0zr2u/notes/yzsbnpc3hl.json added

+++ b/reviews/openreview/dvmka0zr2u/notes/yzsbnpc3hl.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "yzSBNpc3Hl",
+ "replyTo": "aF8URiIhz0",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q6: Curvature accuracy and downstream performance (Q1 from the AC), continued",
+ "comment": "**Q6: Curvature accuracy and downstream performance (Q1 from the AC), continued.** As promised, we conducted an ablation study comparing our CNGC estimator with an idealized oracle setting in which the optimizer has access to the exact GGN blocks in place of our estimate. We calculated the blocks of GGN using full Jacobian.\nWe observed that the two methods exhibit nearly identical optimization trajectories in most cases. This result indicates that our estimator CNGC, despite being substantially cheaper than explicitly computing the GGN from Jacobians (Figure 2, right and Figure 7 in the appendix of our manuscript), performs comparably to the idealized oracle setting in which the exact GGN is directly available. We will include the optimization curves in the final version of the paper. Since images cannot be posted here, we report the corresponding results in the two tables below.\n\n*Table R3: Best test loss achieved for each optimizer and model–dataset combination*\n| Optimizer | mlp_telescope | cnn_occupancy | cnn_air | transf_occupancy | transf_air |\n| --- | --- | --- | --- | --- | --- |\n| GD, PC (ours) | 0.3005 ± 0.0032 | 0.1080 ± 0.0065 | 0.4053 ± 0.0200 | 0.1136 ± 0.0573 | 0.1456 ± 0.0096 |\n| True GGN blocks (oracle) | 0.2981 ± 0.0040 | 0.1082 ± 0.0130 | 0.3887 ± 0.0214 | 0.0918 ± 0.0058 | 0.1384 ± 0.0118 |\n\n\n\n*Table R4: The number of training epochs required to reach within 10% of the best test loss for each optimizer and model–dataset combination*\n| Optimizer | mlp_telescope | cnn_occupancy | cnn_air | transf_occupancy | transf_air |\n| --- | --- | --- | --- | --- | --- |\n| GD, PC (ours) | 4.50 ± 0.50 | 1.10 ± 0.30 | 11.00 ± 3.82 | 3.70 ± 5.46^ | 7.50 ± 2.29 |\n| True GGN blocks (oracle) | 3.40 ± 0.80 | 1.10 ± 0.30 | 3.70 ± 1.10 | 2.40 ± 1.62 | 7.20 ± 3.16 |\n\nAll results are averaged across 10 seeds with one standard deviation. The experimental setup is identical to Figure 3 in the main text. In Table R4 the method marked with ^ did not reach the test error threshold within the allotted training budget."
+ },
+ "createdAt": "2026-07-30T13:28:32.617Z",
+ "modifiedAt": "2026-11-19T17:11:54.841Z",
+ "url": "https://openreview.net/forum?id=DVmkA0zr2U&noteId=yzSBNpc3Hl",
+ "license": "CC-BY-4.0"
+}