potentialpaper

Mechanistic Interpretability of EEG Foundation Models via Sparse Autoencoders

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:47 UTC · 4a6a290aa8cb ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,31 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "eWfHTYapcq"
- }
- ],
- "title": "Mechanistic Interpretability of EEG Foundation Models via Sparse Autoencoders",
- "authors": [
- "William Lehn-Schiøler",
- "Magnus Ruud Kjaer",
- "Rahul Thapa",
- "Magnus Guldberg Pedersen",
- "Anton Mosquera Storgaard",
- "Nick Williams",
- "Andreas Brink-Kjaer",
- "Tue Lehn-Schiøler",
- "Sadasivan Puthusserypady",
- "James Zou",
- "Lars Kai Hansen"
- ],
- "abstract": "EEG foundation models achieve state-of-the-art clinical performance, yet the internal computations driving their predictions remain opaque: a barrier to clinical trust. We apply TopK Sparse Autoencoders (SAEs) across three architecturally distinct EEG transformers: SleepFM, REVE, and LaBraM to extract sparse feature dictionaries from their embeddings. By grounding these features in a clinical taxonomy (abnormality, age, sex, and medication), we benchmark monosemanticity and entanglement across architectures. A single hyperparameter procedure, driven by an intrinsic dictionary health audit, transfers robustly across all three architectures. Via concept steering, we introduce a \"target vs. off-target\" probe area metric to quantify steering selectivity and reveal three operational regimes: selectively steerable, encoded but entangled, and non-encoded. This framework exposes critical representational failures: \"wrecking-ball\" interventions that collapse concept probes, and clinical entanglements, such as age–pathology confounding, where it is impossible to suppress one concept without corrupting the other. Finally, a spectral decoder maps these interventions back to the amplitude spectrum, translating latent manipulations into physiologically interpretable frequency signatures, such as pathological slow-wave suppression with relative sparing of the $\\alpha$ band.",
- "year": 2026,
- "venue": "NeurIPS 2026",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "e2407c30-a3d3-4973-8e84-bfd90549ef5d"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,21 @@
+{
+ "title": "Mechanistic Interpretability of EEG Foundation Models via Sparse Autoencoders",
+ "authors": [
+ "William Lehn-Schiøler",
+ "Magnus Ruud Kjaer",
+ "Rahul Thapa",
+ "Magnus Guldberg Pedersen",
+ "Anton Mosquera Storgaard",
+ "Nick Williams",
+ "Andreas Brink-Kjaer",
+ "Tue Lehn-Schiøler",
+ "Sadasivan Puthusserypady",
+ "James Zou",
+ "Lars Kai Hansen"
+ ],
+ "abstract": "EEG foundation models achieve state-of-the-art clinical performance, yet the internal computations driving their predictions remain opaque: a barrier to clinical trust. We apply TopK Sparse Autoencoders (SAEs) across three architecturally distinct EEG transformers: SleepFM, REVE, and LaBraM to extract sparse feature dictionaries from their embeddings. By grounding these features in a clinical taxonomy (abnormality, age, sex, and medication), we benchmark monosemanticity and entanglement across architectures. A single hyperparameter procedure, driven by an intrinsic dictionary health audit, transfers robustly across all three architectures. Via concept steering, we introduce a \"target vs. off-target\" probe area metric to quantify steering selectivity and reveal three operational regimes: selectively steerable, encoded but entangled, and non-encoded. This framework exposes critical representational failures: \"wrecking-ball\" interventions that collapse concept probes, and clinical entanglements, such as age–pathology confounding, where it is impossible to suppress one concept without corrupting the other. Finally, a spectral decoder maps these interventions back to the amplitude spectrum, translating latent manipulations into physiologically interpretable frequency signatures, such as pathological slow-wave suppression with relative sparing of the $\\alpha$ band.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}