Solving Stochastic Control Under Multiplicative and Internal Noise via Constrained Optimization
Update NeurIPS 2026 submission uzMEs1gPQ6: 6 notes
@openreview[bot] · 2026-11-24 15:57 UTC · 93a459ea037e ·
reviews/openreview/uzmes1gpq6/notes/91disqsmay.json added
+++ b/reviews/openreview/uzmes1gpq6/notes/91disqsmay.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "91diSQSmay",+ "replyTo": "TMp5DjUTxF",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response, part I",+ "comment": "- **I really appreciate the additional references to empirical results that suggest internal noise. I think adding these references to the paper would make the motivation much clearer.**\n\nThanks a lot for asking about this. We will generate a more complete review using this literature.\n\n- **Sensorimotor task; reconciling literature with internal noise levels.**\n\nWe apologize for the lack of clarity and precision in our previous response. We agree that the two statements may appear inconsistent, and we would like to clarify their intended meaning.\n\nOur previous response aimed to establish three separate points: (1) internal noise is empirically motivated; (2) it can produce measurable behavioral effects; and (3) in the stabilization task and parameter regime considered in Fig. 2, its direct contribution to physical-state variability is relatively small compared with the contribution of all other noise sources combined. This demonstrates that the suboptimality of previous solutions (Todorov, 2005) already arises in this setting and does not require large internal noise, and addresses the reviewer’s concern regarding whether our result could be just due to excessively large internal noise – this was not the case.\n\nTo better quantify the magnitude of internal noise relative to **each** of the noises (not combined), we now performed a leave-one-noise-source-out analysis. At each value of $\\sigma_\\eta$, we fixed the LCO control and filter gains obtained for the full model and removed one noise source at a time, thereby measuring the contribution of each source through the same closed loop. Removing process noise $\\xi_t$ reduced physical-state standard deviations by approximately 90% across components and conditions. We note that the process-disturbance term $\\xi_t$ can capture standard perturbation techniques based on external mechanical forces (Kurtzer et al., 2008; Crevecoeur et al., 2012; Bourke et al., 2015; Lowrey et al., 2019), which are often large relative to intrinsic sensory, motor, and internal fluctuations. Now, removing internal noise reduced joint-angle and angular-velocity standard deviations by at most 1.83% and 1.70%, respectively, consistent with the previous discussion. Removing sensory noise reduced joint-angle and angular-velocity standard deviations by at most only 0.033% and 0.139%, respectively, mimicking scenarios in which internal noise outweighs sensory noise, as in Drugowitsch et al. (2016, Fig. 5A). Thus, in this particular task, process disturbances determine most of the absolute behavioral variability, while the direct contribution of internal noise is secondary (yet larger than sensory and multiplicative motor noise – multiplicative motor noise has a smaller effect than sensory noise). \n\nAlthough the above set of parameters models scenarios where internal noise is larger than sensory noise, it is important to note that there are equally realistic experimental conditions in which the reverse occurs and internal noise can be less impactful than sensory noise. For instance, in Drugowitsch et al. (2016), internal noise could be made less important relative to sensory noise simply by increasing the level of sensory noise in the grating stimulus through lower contrast, a manipulation that would necessarily increase sensory uncertainty. Similarly, in Wimmer et al. (2014), strong sensory noise could be added to the stimulus so that uncertainty about its location would become much larger than the internal-noise contribution.\n\n[response continues below]"+ },+ "createdAt": "2026-08-01T15:45:15.983Z",+ "modifiedAt": "2026-11-19T16:44:12.992Z",+ "url": "https://openreview.net/forum?id=uzMEs1gPQ6¬eId=91diSQSmay",+ "license": "CC-BY-4.0"+}
reviews/openreview/uzmes1gpq6/notes/acx94775rf.json modified
+++ b/reviews/openreview/uzmes1gpq6/notes/acx94775rf.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 2C4X","content": {- "metareview": "This paper addresses the stochastic optimal control problem in partially observable linear systems with signal-dependent noise in the dynamics and observation, and internal additive noise. It extends the existing solution (Todorov 2005), which is known to be suboptimal in certain regimes. The work provides a reformulation of the optimal control problem as a constrained optimization problem, allowing for significant speedup of the method. Experiments on two specific settings are provided to show the speedup relative to a previously published method (Damiani et al., 2024) and an improvement relative to the method by Todorov (2005) when the internal additive noise is high. \n\nThe topic is relevant to the fields of optimal control and biological motor control. The paper is well written, the figures are informative and well formatted, and the theoretical development of the reformulation as constrained optimization is clear. Derivations are included and sound as far as I have checked.\n\nThe authors should address the following points:\n- novelty. How much of a theoretical departure are the current results compared to the gradient-based numerical algorithm (Damiani et al., 2024), see reviewer SJuY?\n- implications of the assumption $S_0^{xz}= S_0^{zz}$ in theorem 2\n- initialization, robustness to initialization, and convergence guarantees, see reviewer rGYw\n- broader significance and biological reality of additive internal noise, particularly the regime where the noise levels make a difference in the control, see reviewer SJuY?\n- the experiments investigating computational efficiency with state-of-the-art cost minimization are considering a very restricted and unrealistic regime, namely m=p=k=n and H=I\n- clarification of the details of the experimental setup and evaluations in the optimal control in a redundant sensorimotor task\n- code and pseudo-code for algorithm 1 availability"+ "metareview": "This paper addresses the stochastic optimal control problem in partially observable linear systems with signal-dependent noise in the dynamics and observation, and internal additive noise. It extends the existing solution (Todorov 2005), which is known to be suboptimal in certain regimes. The work provides a reformulation of the optimal control problem as a constrained optimization problem, allowing for significant speedup of the method. Experiments on two specific settings are provided to show the speedup relative to a previously published method (Damiani et al., 2024) and an improvement relative to the method by Todorov (2005) when the internal additive noise is high. \n\nThe topic is relevant to the fields of optimal control and biological motor control. The paper is well written, the figures are informative and well formatted, and the theoretical development of the reformulation as constrained optimization is clear. Derivations are included and sound as far as I have checked.\n\nThe authors should address the following points:\n- novelty. How much of a theoretical departure are the current results compared to the gradient-based numerical algorithm (Damiani et al., 2024), see reviewer SJuY?\n- implications of the assumption $S_0^{xz}= S_0^{zz}$ in theorem 2\n- initialization, robustness to initialization, and convergence guarantees, see reviewer rGYw\n- broader significance and biological reality of additive internal noise, particularly the regime where the noise levels make a difference in the control, see reviewer SJuY?\n- the experiments investigating computational efficiency with state-of-the-art cost minimization are considering a very restricted and unrealistic regime, namely m=p=k=n and H=I\n- clarification of the details of the experimental setup and evaluations in the optimal control in a redundant sensorimotor task\n- code and pseudo-code for algorithm 1 availability",+ "final_justification": "This paper addresses the stochastic optimal control problem in partially observable linear systems with signal-dependent noise in the dynamics and observation, and internal additive noise. It extends the existing solution (Todorov 2005), which is known to be suboptimal in certain regimes. The work provides a reformulation of the optimal control problem as a constrained optimization problem, allowing for significant speedup of the method. Experiments on two specific settings are provided to show the speedup relative to a previously published method (Damiani et al., 2024) and an improvement relative to the method by Todorov (2005) when the internal additive noise is high.\nThe reviewers commented on a number of positive aspects of the work: the topic is relevant to the fields of optimal control and biological motor control, the paper is well written, the experiments and figures are informative, and the theoretical development of the reformulation as constrained optimization is clear.\nOf primary concern were the novelty of the contribution in light of Damiani et al. (2024), the biologically plausibility of the range of internal noise considered in the paper, and some of the empirical tasks considered in the experiments. While some disagreement among the reviewers' evaluations remained, the paper is a solid contribution to the field of motor control and is particularly relevant to inverse optimal control. The authors should implement all additions, clarifications, and corrections promised in the rebuttal and pay particular attention to: including the motivation for internal noise; the discussion, quantification, and experimental validation of the consequences of the biological range of internal noise. Overall, the paper is a solid contribution that should be of interest to the NeurIPS community and the field of biological motor control."},"createdAt": "2026-07-22T10:21:35.948Z",- "modifiedAt": "2026-11-18T15:23:51.750Z",+ "modifiedAt": "2026-11-19T05:02:26.914Z","url": "https://openreview.net/forum?id=uzMEs1gPQ6¬eId=aCX94775RF","license": "CC-BY-4.0"}
reviews/openreview/uzmes1gpq6/notes/b6fd1bvpku.json added
+++ b/reviews/openreview/uzmes1gpq6/notes/b6fd1bvpku.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "B6fd1bVpku",+ "replyTo": "pQULjMGZxB",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response, part III",+ "comment": "- Additional experiment for a psychophysically informed noise calibration.\nTo further strengthen the psychophysical calibration of the noise sources, and following the reviewer’s useful suggestion to replace the stabilization task in the main text with the reaching task, we present additional analyses of the latter.\n\nWe introduced a more precise, literature-informed calibration of the noise regime in the new reaching task. We used literature-based values where closely related empirical estimates were available and calibrated the remaining terms to match realistic behavior.\n\nSpecifically, additive sensory noise was set to $\\sigma_\\omega=0.9^\\circ=0.0157\\,\\mathrm{rad}$, a representative value within the $0.6^\\circ$--$1.1^\\circ$ standard-deviation range inferred by Van Beers et al. (1998) for the precision of shoulder- and elbow-angle information. \n\nThe multiplicative motor-noise coefficient was set to $\\sigma_\\epsilon=0.10$. This value is close to the signal-dependent noise coefficients used by Liu and Todorov (2007), whose optimal-control model of reaching was calibrated so that its baseline variability reproduces the observed variability structure of human reaching movements. \n\nThe multiplicative sensory-noise coefficient was kept at its original small reaching-task value, $\\sigma_\\rho=0.01$. We did not identify a directly transferable psychophysical estimate for this model-specific parameter. Nevertheless, multiplicative sensory noise has been calibrated against psychophysical measurements in related optimal-control models: Sims et al. (2011), for example, calibrated position- and velocity-dependent visual noise to Weber fractions of 0.05 and 0.08, respectively. Because their parameterization differs from ours, we use this only as qualitative support for a small multiplicative sensory contribution, rather than as a direct numerical match.\n\nAfter fixing these intrinsic sensory and motor parameters, we calibrated $\\sigma_\\xi$ so that, at zero internal noise, the terminal elbow-angle standard deviation was $8.55\\%$ of the $20^\\circ$ movement amplitude. This lies in the same broad relative range as the endpoint dispersion reported by van Beers et al. (2004), as already discussed in previous answers. As discussed above, $\\xi_t$ should be interpreted as an effective process-disturbance term that can include unpredictable perturbations acting on the plant or environment. Experimental studies have examined externally imposed unstable force fields and mechanical perturbations during postural and reaching tasks (Burdet et al., 2001; Crevecoeur et al., 2012; Crevecoeur & Scott, 2013). Such disturbances can produce deviations considerably larger than natural trial-to-trial variability. This contribution can therefore be substantially larger than those of intrinsic sensory, motor, or internal noise without implying an unrealistic intrinsic-noise regime.\n\nInternal noise was then swept in $\\sigma_\\eta\\in[0,0.04]$, with all other noise parameters held fixed. The range was selected using two complementary criteria. First, total endpoint variability had to remain within an experimentally plausible range throughout the sweep. Second, the internal-noise effect had to fall within a regime in which its contribution was comparable to or larger than those of sensory and multiplicative motor noise, while remaining secondary to overall behavioral variability. This is consistent with the literature discussed in previous answers and ensures that the resulting modulation of the optimal control strategy is not driven by a dominant contribution of internal noise.\n\nA complementary leave-one-noise-source-out analysis supported precisely this relative ordering. Across the nonzero values of $\\sigma_\\eta$, removing process noise reduced terminal elbow standard deviation by 78.2%--65.4%, confirming that process disturbances remained the dominant direct contributor. Removing internal noise produced reductions of 1.2%--5.2%, larger at every tested value than those produced by removing sensory noise (0.8%--0.4%) or multiplicative motor noise (0.6%--0.7%). \n\nAll the main results of the paper are confirmed here. The LCO advantage increased systematically with internal noise. At $\\sigma_\\eta=0$, TOD and LCO coincided, with $J=162.7$. At every nonzero value, LCO attained a lower expected cost, with the relative improvement increasing from 0.12% to 50.40%. At $\\sigma_\\eta=0.011$, $0.019$, $0.029$, and $0.040$, the improvements were 5.90%, 17.72%, 34.52%, and 50.40%, respectively.\n\nEndpoint variability remained within the broad behavioral range used for calibration, increasing only from 8.55% to 10.46% of movement amplitude across the complete sweep. The main mechanistic and behavioral signatures of Fig.2 were also preserved. For LCO, the time-averaged log-pseudodeterminant of the filter gain increased, whereas that of the control gain decreased, indicating opposite changes in the volume scaling of the sensory-input and control-readout maps."+ },+ "createdAt": "2026-08-03T00:10:03.689Z",+ "modifiedAt": "2026-11-19T16:44:12.976Z",+ "url": "https://openreview.net/forum?id=uzMEs1gPQ6¬eId=B6fd1bVpku",+ "license": "CC-BY-4.0"+}
reviews/openreview/uzmes1gpq6/notes/eiwzzrndby.json added
+++ b/reviews/openreview/uzmes1gpq6/notes/eiwzzrndby.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "eiwZzrnDbY",+ "replyTo": "pQULjMGZxB",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response, part IV",+ "comment": "[continues from Response, part III]\n\nThe LCO peak absolute elbow velocity also retained the non-monotonic dependence on internal noise observed in Fig. 2h: it increased from $76.7^\\circ/\\mathrm{s}$ to $80.1^\\circ/\\mathrm{s}$ near $\\sigma_\\eta=0.019$ and then decreased to $76.7^\\circ/\\mathrm{s}$ at $\\sigma_\\eta=0.04$. By contrast, TOD predicted a strictly monotonic increase from $76.7^\\circ/\\mathrm{s}$ to $83.1^\\circ/\\mathrm{s}$. These values are of the same order as the average angular velocities reported for $20^\\circ$ single-joint elbow reaches (Gribble and Ostry, 1999), and the movement profiles remained smooth, single-peaked, and approximately bell-shaped throughout. \n\nWe will promote this reaching task having experimentally calibrated and realistic values of noises to the main text and retain the stabilization analyses in the appendix. \n\nWe thank the reviewer again for prompting this stronger empirical validation."+ },+ "createdAt": "2026-08-03T00:10:41.376Z",+ "modifiedAt": "2026-11-19T16:44:13.177Z",+ "url": "https://openreview.net/forum?id=uzMEs1gPQ6¬eId=eiwZzrnDbY",+ "license": "CC-BY-4.0"+}
reviews/openreview/uzmes1gpq6/notes/tmp5djutxf.json added
+++ b/reviews/openreview/uzmes1gpq6/notes/tmp5djutxf.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "TMp5DjUTxF",+ "replyTo": "pQULjMGZxB",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer SJuY",+ "content": {+ "title": "Response to author rebuttal",+ "comment": "#### Justification of internal noise\n\nI really appreciate the additional references to empirical results that suggest internal noise. I think adding these references to the paper would make the motivation much clearer.\n\n#### Sensorimotor task\n\nThanks for these new analyses of the behavioural effects of internal noise, which show that \"internal noise produced a measurable but bounded behavioural modulation, small relative to the other noise sources combined\". I am not sure how this observation fits with the empirical results cited in the previous paragraph that \"its effects may be comparable to or larger than sensory and motor noise\". How should I reconcile these two statements?\n\nBased on these potentially conflicting results, my original point (that a psychophysical calibration of the noise sources would make the empirical evaluation much stronger) still stands.\n\n#### New reaching task\n\nThanks, these results with a more realistic task are much stronger and come closer to being interpretable in terms of the behavioural effects of internal noise. I would suggest replacing the stabilisation task with the reaching task.\n\n#### Internal noise vs. model mismatch\n\nWouldn't decreasing (rather than increasing) the subjective value of the sensory noise magnitude be a stronger test of whether a wrong internal model can have similar behavioural effects as internal noise?\n\n#### Novelty\n\nThanks for clarifying. I agree that this paper is a more complete version of the previously published work (Damiani et al., 2024).\n \n#### Linearity\n\nI still think some kind of analysis using approximate non-linear control techniques would be interesting, but concede that this is beyond the scope of the current paper."+ },+ "createdAt": "2026-07-31T15:30:18.988Z",+ "modifiedAt": "2026-11-19T16:44:12.987Z",+ "url": "https://openreview.net/forum?id=uzMEs1gPQ6¬eId=TMp5DjUTxF",+ "license": "CC-BY-4.0"+}
reviews/openreview/uzmes1gpq6/notes/va08gwgqkc.json added
+++ b/reviews/openreview/uzmes1gpq6/notes/va08gwgqkc.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "vA08gWGqKC",+ "replyTo": "91diSQSmay",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response, part II",+ "comment": "[continuation of “Sensorimotor task; reconciling literature with internal noise levels”]\n\nTo test whether the advantage of LCO persists in this other regime where internal noise is smaller than sensory noise, we repeated the stabilization task of Fig. 2 after increasing the coefficients of additive sensory, control-dependent motor, and multiplicative sensory noise tenfold, from 0.1 to 1.0. Process noise was kept fixed at $\\sigma_\\xi=0.1$, while internal noise was swept over $\\sigma_{\\eta} \\in \\\\{ 0,0.1,0.2,0.3,0.4 \\\\}$. TOD and LCO were recomputed independently at every value of $\\sigma_{\\eta}$. We again quantified the contribution of each source to task-relevant physical variability using the same leave-one-noise-source-out analysis. Across all nonzero values of $\\sigma_\\eta$, removing process noise $\\xi_t$ reduced the mean joint-angle standard deviation by approximately 80%, again resembling a task dominated by external disturbances as commented above. The corresponding reductions were 1.8%--2.2% when sensory noise was removed. By comparison, removing internal noise produced reductions of only 0.4%--0.5%. Therefore, in this case, the effect of sensory noise outweighs internal noise. Despite this rescaling, the performance advantage of LCO remained substantial and increased with internal noise. Relative to TOD, LCO reduced the expected cost by 8.77%, 25.28%, 40.28%, and 52.17% at $\\sigma_\\eta=0.1$, $0.2$, $0.3$, and $0.4$, respectively. \n\nTaken together, these analyses confirm that the solutions found by LCO can substantially improve cost minimization relative to Todorov (2005), regardless of whether internal noise is small or large relative to sensory and motor noise.\n\nThese results complement the new reaching-task analysis, in which the overall noise regime is instead anchored to an experimentally observed range of endpoint variability.\n\nWe thank the reviewer for prompting us to clarify these points. We will add this discussion in the manuscript.\n\n- **New reaching task; I would suggest replacing the stabilisation task with the reaching task.**\n\nThat is a good point. We will do that.\n\n- **Internal noise vs. model mismatch; Internal noise vs. model mismatch. Wouldn't decreasing[…]**\n\nWe thank the reviewer for this interesting suggestion. We agree that decreasing the subjective sensory-noise magnitude provides a particularly informative comparison, because it increases reliance on sensory feedback and can therefore resemble one effect of internal noise. More generally, both overestimating and underestimating sensory noise make the internal model incorrect and lead to filter gains that are suboptimal when evaluated in the true system, although they need not produce the same behavioral signatures.\n\nWe therefore repeated the analysis in the same elbow-reaching task with the true sensory-noise amplitude fixed at $\\sigma_{\\omega,\\mathrm{true}}=0.05$. In the model-mismatch sweep, we set $\\sigma_\\eta=0$, progressively decreased the assumed sensory-noise amplitude from $\\sigma_{\\omega,\\mathrm{assumed}}=0.05$ to $0.016$, optimized the filter and control gains under the assumed model, and then froze and evaluated them in the true system. Separately, we kept the sensory model correct and increased internal noise from $\\sigma_\\eta=0$ to $0.03$. All other noise parameters were unchanged.\n\nIn both manipulations, terminal elbow variability remained in a comparable and behaviorally realistic range, around 10% of the $20^\\circ$ movement amplitude, similarly to the previous analysis. The increase in true cost was also comparable across the two sweeps, reaching approximately 5-6% under sensory-noise underestimation and 4% under internal noise.\n\nDespite this, the two manipulations produced clearly distinguishable signatures. Underestimating sensory noise caused peak velocity to increase monotonically, from approximately $76.9$ to $80.0\\,\\mathrm{deg/s}$. In contrast, internal noise reproduced the non-monotonic modulation reported previously. The gain changes were also qualitatively different: under sensory-noise underestimation, both $K$ and $L$ increased, whereas with internal noise, $K$ increased but $L$ decreased. Thus, even this stronger model-mismatch test does not reproduce the characteristic joint behavioral and control signatures of internal noise, which therefore remain distinguishable.\n\n- **Novelty. I agree that this paper is a more complete version of the previously published work (Damiani et al., 2024).**\n\nThanks a lot.\n\n- **Linearity. Concede that this is beyond the scope of the current paper.**\n\nThanks a lot."+ },+ "createdAt": "2026-08-01T15:48:39.759Z",+ "modifiedAt": "2026-11-19T16:44:12.985Z",+ "url": "https://openreview.net/forum?id=uzMEs1gPQ6¬eId=vA08gWGqKC",+ "license": "CC-BY-4.0"+}