potentialpaper

Your Hypergradient is Skewed: Antithetic Neumann Estimation for Bilevel Optimization

Import NeurIPS 2026 submission 6hdVJxlWcS: 8 notes

@openreview[bot] · 2026-11-22 17:54 UTC · 210bc010c4dc

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,24 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "6hdVJxlWcS"
+ }
+ ],
+ "title": "Your Hypergradient is Skewed: Antithetic Neumann Estimation for Bilevel Optimization",
+ "authors": [
+ "Jason Bohne",
+ "Pawel Polak",
+ "Gary Kazantsev",
+ "David S Rosenberg"
+ ],
+ "abstract": "Bilevel optimization is a core tool in practical machine learning workflows, including hyperparameter tuning, data reweighting, robust learning, reinforcement learning, and imbalanced classification. Hypergradient computation requires the inverse of the inner Hessian, typically estimated via a truncated Neumann series. While existing analyses focus on bias and variance, we show that the product structure of the Neumann series introduces a third source of error: skewness. We identify that, unlike ordinary gradients, whose asymmetry is suppressed by mini-batch averaging, the Neumann estimator amplifies skewness across factors, with the third-moment error growing, under weak contraction, with truncation depth, inner condition number, and per-factor noise asymmetry. This arises in many practical settings such as corrupted labels, outliers, heterogeneous or class-imbalanced datasets. To address this, we introduce the Antithetic Neumann Estimator (ANE) which pairs each Hessian sample with a mirrored counterpart around a reference Hessian and averages the resulting inverse-Hessian estimates. With an exact reference the antithetic product retains only even-order noise, eliminating all odd-order perturbation terms; with an approximate reference, the residual odd-order contribution is bounded linearly in the reference error. ANE requires only a modification of the Hessian–vector step and combines with existing stochastic or variance-reduced bilevel methods. We instantiate ANE-SGD and ANE-VR, the latter adding recursive variance reduction. Across robust regression, data cleaning, offline reinforcement learning, and imbalanced classification, ANE-based methods improve on stochastic and variance-reduced baselines on every task (20 seeds each), lowering loss by 4–25% relative to the best baseline; the largest gains, on robust regression, are a 25% lower test loss and a 54% higher test $R^2$. These results support skewness reduction as a practical, complementary mechanism for improving hypergradient quality.",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/6hdvjxlwcs/forms.json added

+++ b/reviews/openreview/6hdvjxlwcs/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/6hdvjxlwcs/notes/6y1ca4ovlr.json added

+++ b/reviews/openreview/6hdvjxlwcs/notes/6y1ca4ovlr.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "6Y1cA4Ovlr",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer AXL7",
+ "content": {
+ "summary": "The paper proposes an antithetic estimator for Neumann-series hypergradient estimation in stochastic bilevel optimization. The main idea is to pair stochastic Hessian samples with mirrored samples around a reference Hessian, so that odd-order perturbation terms cancel in the Neumann product expansion. The paper gives estimator-level analysis and evaluates the resulting ANE-SGD and ANE-VR methods on synthetic and applied bilevel problems.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "### Strengths\nThe main observation of the paper is useful and the resulting proposed algorithms are well motivated: asymmetric Hessian noise can affect the estimator in ways that prior art does not capture through variance-only analysis. The proposed construction is natural and understandable.\n\nThe authors establish clean results under strong assumptions which give good motivation for the construction of the ANE algorithms. \n\n### Weaknesses\nThe experiments are promising but they might not be fully explaining characteristics of the proposed method. \nIt is clear in the synthetic experiment that the cancellation of the odd-order perturbation terms explains the gains, but it is less clear in the other experiments.\nANE also uses additional Hessian-vector computations and uses reference information. \nThe timing results help, but the comparison would be much stronger with HVP-budget-matched and wall-clock-matched baselines, including baselines that use the same reference information without antithetic mirroring.\n\nI think there should be more experiments targeted at these discussions in general, as well as on more specific problems to showcase in particular the limitations of the method.",
+ "quality": 4,
+ "clarity": 4,
+ "significance": 3,
+ "originality": 3,
+ "questions": "### General Questions\n1. It would be interesting to show failure modes of ANE, e.g. if the Hessian noise is close to symmetric? \n2. How costly and how often to update the reference Hessian should also be discussed.\n3. Could you expand on the cost overhead of the ANE? How much more costly are the Hessian vector products compared to baselines?\n\n### Questions on the Experiments\n1. Would it be possible to add diagnostics for the real tasks to track estimates of bias, variance, signed third moments and the paper's third moment proxy? I think that would help attribute the performance gains to the proposed method.\n2. Could there be a synthetic or controlled experiment showcasing where ANE fails to improve over the baselines?\n3. Is there a reason to plot the mean +/- standard error in Figure 2 and report mean +/- standard deviation in Table 4?",
+ "limitations": "Some limitations are mentioned, including computational overhead and the fact that odd-degree cancellation is not a complete theory of hypergradient skewness.\nSome other limitations are missing in my opinion, for example would it be worth discussing the gap between the exact-reference analysis and the approximate-reference implementation.\nAnother discussion on satisfying the assumptions of the theorems would also be beneficial.",
+ "rating": 5,
+ "confidence": 1,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "Please review Figure 2, you can surely make the plots bigger and save blank space in the middle column.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "Considering the questions from my review answered, and the good rebuttal provided to other reviewers I will update my rating."
+ },
+ "createdAt": "2026-06-24T22:27:55.972Z",
+ "modifiedAt": "2026-11-18T13:43:22.637Z",
+ "url": "https://openreview.net/forum?id=6hdVJxlWcS&noteId=6Y1cA4Ovlr",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/6hdvjxlwcs/notes/by6vmdcc5o.json added

+++ b/reviews/openreview/6hdvjxlwcs/notes/by6vmdcc5o.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "By6vmDcc5o",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair VENY",
+ "content": {
+ "metareview": "> I have read the authors’ response and the reviewer discussion. This paper identifies skewness as an additional source of error in stochastic Neumann hypergradient estimators and proposes ANE, which uses antithetic Hessian pairing around a reference Hessian to cancel odd-order perturbation terms.\n>\n> The response substantially addressed the main concerns in the initial meta-review. The authors clearly distinguished standardized skewness from the scale-sensitive third-moment diagnostic and clarified which quantity is relevant to the experiments. They introduced compute-, variance-, and reference-matched controls that provide evidence that the observed estimator improvement arises from antithetic cancellation rather than merely from additional computation, variance reduction, or access to a reference Hessian. A symmetric-noise control also demonstrates the expected failure mode when skewness is absent.\n>\n> The authors further clarified that the core cancellation and reference-sensitivity results apply to general matrix-valued noise through operator-norm arguments rather than requiring a shared eigenbasis. They provided an iterate-level convergence bound, expanded all real-task evaluations to 20 random seeds, and reported computational costs across the truncation depths used in practice. Two reviewers raised their ratings to 5 after the response, while the remaining reviewer retained a borderline-accept rating.\n>\n> Some limitations remain. ANE incurs approximately 2.4 to 3.1 times the per-step computational cost of the standard estimator, and the approximate-reference analysis relies on a contraction condition that is not directly verified in all experiments. Moreover, estimator-level skewness reduction does not by itself establish that every downstream performance improvement is caused exclusively by skewness correction. These limitations are now clearly characterized and represent transparent trade-offs rather than fundamental weaknesses.\n>\n> Overall, the paper presents an original and useful perspective on stochastic hypergradient estimation, supported by convincing controlled experiments and strengthened theoretical analysis."
+ },
+ "createdAt": "2026-07-20T03:50:19.059Z",
+ "modifiedAt": "2026-11-18T15:24:12.051Z",
+ "url": "https://openreview.net/forum?id=6hdVJxlWcS&noteId=By6vmDcc5o",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/6hdvjxlwcs/notes/ck2iyzkqmz.json added

+++ b/reviews/openreview/6hdvjxlwcs/notes/ck2iyzkqmz.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "CK2IYZKQmz",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer qj4Y",
+ "content": {
+ "summary": "This paper focuses on the quality of hypergradient estimation in bilevel optimization. The computation of hypergradients relies on inverse Hessian-vector products, which are commonly approximated using truncated Neumann series for scalability. While previous research has primarily evaluated these estimators from the perspectives of bias and variance, this paper reveals that the product structure of random Hessian factors in the Neumann series introduces a third type of error related to skewness or the third moment. This error can be significantly amplified in asymmetric noise scenarios, such as corrupted labels and imbalanced classification. To address this, the authors propose the Antithetic Neumann Estimator ANE. By constructing a mirrored counterpart around a reference Hessian for each random sample and averaging them, ANE algebraically cancels the odd-order perturbation terms in the product expansion. This method serves as a plug-and-play module and can be complementarily combined with recursive variance reduction techniques. The theoretical claims are validated on synthetic data and four real-world tasks, demonstrating that ANE substantially reduces the absolute third-moment proxy $\\mathcal{M}_3(\\xi)$ of the vector error.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "## Strengths\n\n1. The analytical perspective is novel and self-consistent. While existing literature on Neumann-based bilevel optimization primarily evaluates estimators based on bias and variance, this paper shifts the focus to the third-moment contributions brought by the product structure. Theorem 3.1 provides clear scalar derivations, including exact and perturbative expressions for variance $\\text{Var}(P_m)$, the per-factor third central moment $\\mu_3'$, and standardized skewness $\\gamma_1(P_m)$. This offers a clear, testable, and original entry point.\n2. The theoretical derivations are concise and correct. Section 3.4 uses a clear two-factor intuition $\\frac{1}{2}[(a+\\delta_1)(a+\\delta_2)+(a-\\delta_1)(a-\\delta_2)] = a^2+\\delta_1\\delta_2$ to explain the principle of linear term cancellation. Proposition 3.4 rigorously extends this to arbitrary depths, proving the cancellation of odd-order terms through a subset summation argument, which is logically sound. Other derivations are also clear and self-consistent.\n3. The proposed method is highly modular. ANE only modifies the inverse-Hessian-vector product primitive, leaving the inner solver, outer step size, and single-loop structure unchanged. It can also be easily combined with recursive variance reduction to form ANE-VR, as shown in the algorithms and Table 1.\n4. The experimental evaluation covers a broad range of tasks. The four tasks encompass regression, classification, offline reinforcement learning, and imbalanced classification. The reasoning chain is complete and self-consistent, enhancing the credibility that the proposed mechanism indeed exists in these practical scenarios.\n\n## Weaknesses\n\n1. The paper acknowledges that ANE removes linear perturbation terms while canceling odd-order terms, which inherently affects the variance. Therefore, the empirical improvements in test metrics cannot be cleanly attributed solely to the claimed mechanism of third-moment or skewness reduction, as ANE conflates variance reduction and skewness reduction effects. Figure 1 shows empirically that the variance is comparable, explicitly stating that this is not a general theoretical consequence. It would be necessary to control the variance in synthetic settings and scan the third moment independently to verify if skewness reduction still brings improvements when the variance is fixed.\n2. The ablation study shows that $\\tau = 0.5$ performs comparably to $\\tau = 1.0$ within one standard error across all tasks. However, Proposition 3.4 and Remark 3.7 explicitly state that complete cancellation of odd-order terms only holds when $\\tau = 1$ and the reference is exact; linear terms are not fully canceled when $\\tau < 1$. The authors need to explain why the mechanistically unique setting of $\\tau = 1$ is not empirically necessary.\n3. The paper only provides properties at the estimator level, such as cancellation and sensitivity, but lacks a convergence rate or oracle complexity analysis for the bilevel optimization using ANE. In contrast, the baselines it compares against, such as StocBiO and SUSTAIN, provide explicit convergence guarantees. It would be helpful to supplement a convergence proposition or clearly argue that ANE does not break existing convergence guarantees.\n4. There are flaws in statistical strength and baseline coverage. First, the number of random seeds is inconsistent across tasks, and the ablation study uses only 3 seeds. Second, some performance gains are marginal and their significance is questionable given the standard deviations. Furthermore, the headline figures of up to 25% and 54% improvements all come from a single best-performing task, which raises concerns about cherry-picking. Finally, in the fraud detection task, the loss for $\\tau = 0.9$ is 0.271, which is better than the 0.278 achieved by $\\tau = 1.0$, yet the main text defaults to $\\tau = 1.0$ without clarifying this discrepancy.",
+ "quality": 2,
+ "clarity": 3,
+ "significance": 2,
+ "originality": 3,
+ "questions": "1. Is it possible to experimentally separate skewness reduction from variance reduction? You acknowledge that ANE affects variance by removing linear perturbation terms. Please provide a controlled baseline where the variance is fixed to directly verify whether skewness reduction still leads to metric improvements under constant variance.\n2. How do you reconcile the comparable performance of $\\tau = 0.5$ and $\\tau = 1.0$ with the narrative that complete odd-order cancellation, which only occurs at $\\tau = 1$, is the key mechanism? Could you provide a fine-grained dependence curve of the absolute third-moment proxy $\\mathcal{M}_3(\\xi)$ against the mirror strength $\\tau$?\n3. What is the total computational cost after accounting for the overhead of refreshing the reference Hessian? How does this cost scale with model size, and is periodic full-batch snapshotting feasible at larger scales?\n4. Theorem 3.1 and Proposition 3.2 rely on a scalar multiplicative model where the random Hessian shares the eigenbasis with the true Hessian. Which conclusions still hold when the noise is generally matrix-valued and does not share the eigenbasis?\n\nIf the questions raised above can be well addressed, I am willing to raise my score.",
+ "limitations": "yes",
+ "rating": 5,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "no",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I am raising my score to 5 as the authors have provided a thorough and convincing rebuttal that directly addresses the core concerns raised by the reviewers and the Area Chair. \n\nResolved issues:\n1. Confounding with variance reduction: The introduction of the matched-budget and matched-variance Standard (2x) baseline successfully isolated the empirical gains of skewness reduction, resolving the most critical concern regarding the exact source of the improvements.\n2. Theoretical gaps: The addition of the iterate-level convergence bound showing a higher-order error term, along with the clarification that the core theorems rely on operator norms rather than shared eigenbasis assumptions, completes the theoretical picture.\n3. Practical configurations and robustness: The algebraic justification for using a mirror strength of 0.5, the comprehensive wall-clock sweep across different truncation depths, and the expansion to 20 random seeds effectively resolve the questions regarding empirical parameter choices, computational scaling, and statistical reliability.\n\nUnresolved issues:\nNo critical scientific issues remain. It is acknowledged that the method inherently incurs a 2.4 to 3.1 times computational overhead per step compared to standard baselines. However, this is a reasonable and now transparently documented algorithmic trade-off rather than a flaw."
+ },
+ "createdAt": "2026-06-23T03:44:10.061Z",
+ "modifiedAt": "2026-11-18T13:43:24.027Z",
+ "url": "https://openreview.net/forum?id=6hdVJxlWcS&noteId=CK2IYZKQmz",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/6hdvjxlwcs/notes/im2ewdgdfh.json added

+++ b/reviews/openreview/6hdvjxlwcs/notes/im2ewdgdfh.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "IM2eWdGDFh",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer RAQS",
+ "content": {
+ "summary": "The paper identifies a third source of error in stochastic Neumann hypergradient estimators (in addition to bias and variance): the amplification of skewness (third-order moments) due to the multiplicative product structure of the Neumann series. The core theoretical contribution is a scalar product model (Theorem 3.1) showing that the signed standardized skewness of the truncated product scales as $\\mu'_3/(\\sigma^3\\sqrt{m})$ in the perturbative regime. The paper additionally conjectures (in Claim C1) that the scale-sensitive diagnostic $M_3(\\xi) = \\mathbb{E}[|\\xi - \\mathbb{E}\\xi|^3]$ can grow with truncation depth $m$ and conditioning $\\kappa_g$ in certain regimes. Figure 1 is presented as empirical evidence consistent with this claim, but no theorem establishes it. A coordinate-wise lift (Proposition 3.2) connects the scalar analysis to the vector inverse-Hessian estimate. To reduce this skewness, the paper proposes the Antithetic Neumann Estimator (ANE), which mirrors each stochastic Hessian factor around a reference $\\bar{H}$ and averages the two resulting products; under an exact reference, all odd perturbation-degree terms cancel, leaving a deviation that is quadratic in the perturbation. Sensitivity to an approximate reference is bounded linearly in the reference error under a uniform contraction assumption. Two algorithms are presented: (1) ANE-SGD (drop-in replacement for the Neumann primitive) and (2) ANE-VR (ANE inside a SARAH/PAGE outer variance-reduction loop). They are evaluated on four bilevel tasks: robust regression, data cleaning (FashionMNIST), offline RL (Acrobot), and imbalanced classification (credit-card fraud).",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths:\nThe identification of skewness as a distinct error source in Neumann products is conceptually new and well-motivated. The scalar product analysis of Theorem 3.1 is fully self-contained, and the proof is elementary and verifiable. The algebraic cancellation result of Proposition 3.4 follows directly from the distributivity identity (equation 9) applied to the forward and mirrored products. The decomposition of the full hypergradient error (Proposition 3.3) isolates the Neumann product as the locus of truncation-depth dependence, making the motivation for targeting $\\hat{v}$ precise. The experimental section carefully distinguishes what is being compared: ANE-SGD vs. StocBiO isolates antithetic estimation, while ANE-VR vs. SUSTAIN isolates the effect of skewness reduction within an otherwise identical outer variance-reduction wrapper. \n\nWeaknesses: \n- Theorem 3.1 establishes that the signed standardized skewness scales as $\\mu'_3/(\\sigma^3\\sqrt{m})$ and therefore decreases with truncation depth $m$ in the perturbative regime. The paper simultaneously claims that the unnormalized third-moment proxy can grow with truncation depth and conditioning. These two statements are not contradictory, but the paper does not state clearly which of the two is the operative mechanism in the experiments. Figure 1(c) plots the absolute third-moment proxy, not the standardized skewness, so it is the unnormalized quantity driving the displayed reductions, which is a bit confusing given the standardized skewness result in the theorem. \n\n- Proposition 3.6, which bounds the sensitivity of ANE to an approximate reference, requires that both mirrored branches are uniformly contractive. The paper acknowledges this is \"stronger than the moment assumptions on stochastic Hessian noise\". In practice, the reference is maintained via periodic large-batch snapshots (Algorithms 1–2, Reference refresh step), and no verification that this contraction condition holds empirically is provided.\n\n- The computational overhead of ANE is presented only at truncation depth $m=5$ in Table 2, with the caveat that this is \"not a general oracle-complexity equivalence\". Since the theoretical motivation for ANE involves a large truncation depth, it would be informative to report overhead at the actual depths used in the experiments. The current table may understate the practical cost.\n\n- The convergence trajectories in Figure 2 show ANE-VR tracking ANE-SGD closely, with Table 4 noting \"once ANE removes the within-estimate odd-degree term, across-iteration VR adds little\". If this pattern is consistent, it suggests that recursive outer variance reduction is redundant given ANE, which would simplify the practical recommendation but also weaken the motivation for ANE-VR as a standalone contribution.\n\n- There is no convergence rate theorem for ANE-SGD or ANE-VR as outer optimization algorithms. The guarantees are entirely at the level of the estimator, not at the level of the iterates.",
+ "quality": 3,
+ "clarity": 2,
+ "significance": 2,
+ "originality": 3,
+ "questions": "- Can you please clarify, for each task, which regime (perturbative or weak-contraction) is operative, and provide the empirically estimated $\\kappa_g$​ and depth values that would place the task in one regime or the other?\n\n- The sensitivity bound requires uniform contraction of both mirrored branches. For the approximate reference maintained via periodic snapshots, is there any empirical check that the mirrored branch remains contractive during training?\n\n- Table 2 reports overhead at $m=5$, but the experimental tasks use larger $m$. Can you report per-iteration wall-clock time at the actual depths used?\n\n- Table 4 shows ANE-VR matching ANE-SGD on Acrobot and Fraud within noise. Is it the right interpretation that skewness reduction subsumes the benefit of outer variance reduction on these tasks? If so, do you consider ANE-SGD sufficient in practice, and under what conditions, if any, would one expect ANE-VR to provide additional benefit over ANE-SGD?",
+ "limitations": "Proposition 3.6 additionally requires a uniform contraction assumption on both mirrored branches that is stronger than the standard Neumann literature and is not verified empirically. The experiments do not include a task where the per-factor noise is symmetric (i.e., $\\mu_3'=0$), which would serve as a negative control confirming that ANE provides no benefit in the absence of asymmetry.",
+ "rating": 4,
+ "confidence": 2,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No serious issues found.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "Based on the comments from the other reviewers and the response from the authors, I would like to maintain my original score."
+ },
+ "createdAt": "2026-06-25T08:46:46.666Z",
+ "modifiedAt": "2026-11-18T13:43:20.944Z",
+ "url": "https://openreview.net/forum?id=6hdVJxlWcS&noteId=IM2eWdGDFh",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/6hdvjxlwcs/notes/irm8tnh0z1.json added

+++ b/reviews/openreview/6hdvjxlwcs/notes/irm8tnh0z1.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "irm8tNh0Z1",
+ "replyTo": "6Y1cA4Ovlr",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We thank the reviewer and address every point below. AC meta-review points addressed: AC2 (W1, Q4), AC4 (Q2, Q3).\n\n**W1: Matched-cost and reference-only baselines.** We add the baselines you ask for: a compute- and variance-matched Standard (\"2x budget\", two averaged Standard estimates), and a reference-only baseline that reuses $\\bar H$ without mirroring. Synthetic control (8 seeds, $\\kappa_g=100$, $m=20$):\n\n| estimator | $\\gamma_1$ | variance |\n|---|---|---|\n| Standard | $2.02\\pm0.23$ | $7.4\\text{e-}3$ |\n| Standard (2x budget) | $1.31\\pm0.11$ | $3.6\\text{e-}3$ |\n| Reference-only ($\\tau=0$) | $1.89\\pm0.19$ | $1.8\\text{e-}3$ |\n| ANE ($\\tau=1$) | $0.30\\pm0.18$ | $3.6\\text{e-}3$ |\n\nStandard (2x) matches ANE's budget and variance but keeps $\\gamma_1$ high (1.31 vs. 0.30); reference-only reuses $\\bar H$ but barely helps (1.89); only ANE's mirroring collapses the skewness. So the gain is the antithetic cancellation, not compute, variance, or the reference. This isolation is at matched compute and matched variance (qj4Y's W1 sweeps it at fixed variance): even a Standard estimator given ANE's $\\approx\\!2m$-HVP budget does not match ANE's skewness reduction. The real-task comparisons in Table 4 are at matched outer-iteration count (ANE's hypergradient-step overhead there is a constant $2.4$–$3.1\\times$, RAQS W3) rather than matched wall-clock.\n\n**Q1: Failure modes under symmetric noise.** We ran this control on the variance-matched synthetic problem (8 seeds): at $\\mu_3'=0$ (symmetric noise) ANE and a same-budget Standard have the same skewness ($\\gamma_1=0.23$ vs. $0.21$; this is the $\\mu_3'=0$ row of the full sweep in qj4Y's W1), so ANE gives no benefit (but also no harm) when there is no asymmetry to cancel. The gain also fades at small $m$ or good conditioning, where the per-factor noise is small.\n\n**Q2: Reference-Hessian update cost and frequency.** The reference is a large-batch snapshot refreshed every $q_{\\mathrm{ref}}=10$ steps: a $\\approx0.2$ ms one-off, independent of $m$, so about $0.02$ ms/step amortized. That is negligible next to the two-branch HVP step (Q3), so the cost is set by the HVP overhead, not the refresh.\n\n**Q3: HVP cost overhead vs. baselines.** ANE runs a forward and a mirrored branch, so about $2m$ HVPs against StocBiO's $m$. At the real depths the inverse-Hessian step costs a roughly constant $2.4$–$3.1\\times$ StocBiO. The paper's Table 2 reports $1.4$–$2.0\\times$ at $m{=}5$, which is smaller because it times the full iteration and the shared inner solve dilutes the ratio.\n\n**Q4: Real-task bias/variance/skewness diagnostics.** The synthetic control in W1 isolates the effect at fixed variance; on the real tasks the per-$m$ skewness diagnostic shows the same (on Fraud, ANE's $\\gamma_1$ is $1.8$–$4\\times$ lower at every $m$, bias unchanged). We will give the full per-task bias/variance/third-moment table in the camera-ready.\n\n**Q5: A controlled negative-result experiment.** This is the same ask as Q1: the $\\mu_3'=0$ control there is exactly a case where ANE gives no gain over a matched Standard.\n\n**Q6: SE vs. SD inconsistency between Figure 2 and Table 4.** The reviewer caught a genuine inconsistency. Figure 2 used standard error for trajectory readability and Table 4 used standard deviation; we will report standard deviation with $n$ stated in both.\n\n**Formatting.** We will make all the requested formatting changes to Figure 2."
+ },
+ "createdAt": "2026-07-28T02:27:08.568Z",
+ "modifiedAt": "2026-11-18T17:19:45.407Z",
+ "url": "https://openreview.net/forum?id=6hdVJxlWcS&noteId=irm8tNh0Z1",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/6hdvjxlwcs/notes/l03pln6phh.json added

+++ b/reviews/openreview/6hdvjxlwcs/notes/l03pln6phh.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "l03PlN6PHh",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "> I have read the authors’ response and the reviewer discussion. This paper identifies skewness as an additional source of error in stochastic Neumann hypergradient estimators and proposes ANE, which uses antithetic Hessian pairing around a reference Hessian to cancel odd-order perturbation terms.\n>\n> The response substantially addressed the main concerns in the initial meta-review. The authors clearly distinguished standardized skewness from the scale-sensitive third-moment diagnostic and clarified which quantity is relevant to the experiments. They introduced compute-, variance-, and reference-matched controls that provide evidence that the observed estimator improvement arises from antithetic cancellation rather than merely from additional computation, variance reduction, or access to a reference Hessian. A symmetric-noise control also demonstrates the expected failure mode when skewness is absent.\n>\n> The authors further clarified that the core cancellation and reference-sensitivity results apply to general matrix-valued noise through operator-norm arguments rather than requiring a shared eigenbasis. They provided an iterate-level convergence bound, expanded all real-task evaluations to 20 random seeds, and reported computational costs across the truncation depths used in practice. Two reviewers raised their ratings to 5 after the response, while the remaining reviewer retained a borderline-accept rating.\n>\n> Some limitations remain. ANE incurs approximately 2.4 to 3.1 times the per-step computational cost of the standard estimator, and the approximate-reference analysis relies on a contraction condition that is not directly verified in all experiments. Moreover, estimator-level skewness reduction does not by itself establish that every downstream performance improvement is caused exclusively by skewness correction. These limitations are now clearly characterized and represent transparent trade-offs rather than fundamental weaknesses.\n>\n> Overall, the paper presents an original and useful perspective on stochastic hypergradient estimation, supported by convincing controlled experiments and strengthened theoretical analysis.",
+ "final_justification": "Please see the updated meta-review for the final justification."
+ },
+ "createdAt": "2026-09-24T11:25:30.346Z",
+ "modifiedAt": "2026-11-18T14:58:03.038Z",
+ "url": "https://openreview.net/forum?id=6hdVJxlWcS&noteId=l03PlN6PHh",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/6hdvjxlwcs/notes/mpx7xiodha.json added

+++ b/reviews/openreview/6hdvjxlwcs/notes/mpx7xiodha.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "mPx7XiOdha",
+ "replyTo": "CK2IYZKQmz",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We sincerely thank the reviewer for their insightful comments and take their points in order. AC meta-review points addressed: AC1 (Q4), AC2 (W1, Q1), AC3 (W2, Q2), AC4 (Q3), AC5 (W4).\n\n**W1: ANE changes variance as well as skewness, so gains may not be skewness-specific.** We isolate skewness at controlled variance. \"Standard (2x)\" averages two independent Standard estimates, matching ANE's $2m$-HVP budget and its variance, with no reference or mirroring. Sweeping $\\mu_3'$ at that fixed variance ($\\kappa_g=100$, $m=20$, 8 seeds):\n\n| $\\mu_3'$ target | Standard (2x) $\\gamma_1$ | ANE $\\gamma_1$ | variance (both) |\n|---|---|---|---|\n| 0 (symmetric control) | $0.21\\pm0.05$ | $0.23\\pm0.03$ | $3.6\\text{e-}3$ |\n| 2 | $0.52\\pm0.05$ | $0.18\\pm0.09$ | $3.6\\text{e-}3$ |\n| 4 | $1.30\\pm0.12$ | $0.20\\pm0.10$ | $3.6\\text{e-}3$ |\n| 6 | $1.98\\pm0.11$ | $0.39\\pm0.17$ | $3.6\\text{e-}3$ |\n\nAt $\\mu_3'=0$ the two are indistinguishable (no leading $\\mu_3'$ term); as $\\mu_3'$ grows, Standard's skewness climbs while ANE's stays flat, at the same variance throughout. So the reduction is the cancellation, not variance or compute. Real data shows the same. A vector estimator has no single skewness, so we fix one projection (the true-hypergradient direction, set in advance and identical for both estimators) and report $\\gamma_1$ along it, where variance divides out: on Fraud (largest standardized skew, App. B.5) ANE's $\\gamma_1$ is $1.8$–$4\\times$ lower at every depth ($0.74\\to0.19$ at $m{=}20$, $0.48\\to0.16$ at $m{=}100$; ANE SE $\\le0.02$), bias unchanged. These are estimator-level results; we do not claim the test-metric gains come from skewness alone. ANE-SGD still beats SUSTAIN on all four tasks even without outer VR, so ANE is practically useful in these asymmetric settings.\n\n**W2: Why $\\tau=1$ is not empirically necessary.** The mechanism is $\\tau$-dependent at every level, but the task metrics saturate. Algebraically a degree-$n$ odd term keeps $c_n(\\tau)=(1-\\tau^n)/2$ of its Standard size, so $\\tau=0.5$ already removes 75% of the leading ($n{=}1$) coefficient and $\\tau=1$ cancels the rest exactly (Eq. 9).\n\nThe effect stays clearly $\\tau$-dependent: standardized skewness drops steadily and is smallest at $\\tau=1$ (synthetic experiment, $\\kappa_g=100$, $m=20$, 8 seeds; Standard $\\gamma_1=2.03$):\n\n| $\\tau$ | 0 | 0.25 | 0.5 | 0.75 | 1.0 |\n|---|---|---|---|---|---|\n| $\\gamma_1$ | 1.89 | 1.70 | 1.29 | 0.55 | 0.30 |\n\nThe remaining improvement beyond $\\tau=0.5$ is small relative to run-to-run variation, though, so the task metrics barely move (Appendix B.4):\n\n| $\\tau$ | Housing $R^2$ | Fashion Acc. | Acrobot $R^2$ | Fraud AUPRC |\n|---|---|---|---|---|\n| 0.5 | 0.61 | 89.1 | 0.18 | 0.918 |\n| 1.0 | 0.60 | 89.3 | 0.20 | 0.925 |\n\nSo $\\tau=1$ stays the clean theoretical choice (exact odd-degree cancellation, Eq. 9), while $\\tau=0.5$ keeps most of the benefit and can be more stable, consistent with the damped-mirroring discussion in Remark 3.7. The absolute proxy $\\mathcal M_3(\\xi)$ stays 71\\%–88\\% below Standard for every $\\tau$; its slight rise near $\\tau=1$ is less informative because $\\mathcal M_3$ is scale-sensitive and also reflects variance, whereas $\\gamma_1$ isolates distributional asymmetry more directly.\n\n**W3: No convergence rate or oracle complexity analysis.** We can lift the estimator-level result to an iterate-level rate using only assumptions already in the paper, with no new smoothness condition. Writing the hypergradient's conditional squared bias, variance, and centered third moment as $\\bar r^2,\\bar\\sigma^2,\\overline M_3$, a second-order descent lemma (using the $L_2$-Lipschitz Hessian of Assumption 4(ii)) telescopes, for $\\alpha\\le 1/(4L_F)$, to\n$$\\begin{aligned}\n\\frac1T\\sum_{t<T}\\mathbb E\\|\\nabla F(\\lambda_t)\\|^2 \\&\\le\\ \\frac{2(F(\\lambda_0)-F_\\star)}{\\alpha T} + \\tfrac52\\bar r^2 + L_F\\alpha\\bar\\sigma^2 + \\tfrac{L_2\\alpha^2}{3}\\overline M_3,\\\\\\\\[4pt]\n\\overline M_3 &= \\begin{cases}O(\\rho^3) & \\text{standard Neumann}\\\\\\\\ O(\\rho^6) & \\text{ANE.}\\end{cases}\n\\end{aligned}$$\nAlmost everything in this bound is shared by the two estimators. Under an exact reference ANE and standard Neumann are both unbiased to $\\mathcal N_m$ (Prop. 3.4), so they have the same $\\bar r^2$ and $\\bar\\sigma^2$ and differ only in $\\overline M_3$: with $\\rho$ the per-factor noise scale, the Neumann-induced third moment is $O(\\rho^3)$ for standard Neumann but $O(\\rho^6)$ for ANE, since ANE's deviation from $\\mathcal N_m$ starts at $O(\\rho^2)$ rather than $O(\\rho)$ (Cor. 3.5). The condition $\\rho<1$ that makes this an improvement is not something ANE adds: the stochastic Neumann series only converges when each factor is contractive, so $\\rho<1$ is already required for standard Neumann (and hence StocBiO/SUSTAIN) to be valid at all. Wherever the baseline estimator converges, then, $\\rho^6<\\rho^3$, so ANE's third moment is strictly smaller rather than merely relabeled. (An approximate reference adds a residual $\\|R\\|$, but it enters only linearly by Prop. 3.6 and stays within a few percent across training by W2, so it does not overturn this gain.) ANE-VR composes with the recursive wrapper; the full statement, assumptions, and proof go in the camera-ready.\n\n**W4: Statistical rigor: seeds, effect sizes, headline numbers, the fraud discrepancy.** Seed counts were 20/5/20/10 (Housing/Fashion/Acrobot/Fraud), smaller on the larger datasets to save compute; we have rerun all four real-task comparisons at 20 seeds, with ordering and gaps unchanged. Controls and timing report their own $n$, which we will list throughout. On the marginal-gains worry, we will show effect sizes with their standard deviations and lead with the across-task picture rather than the best case, flagging the 25% and 54% numbers as Housing-specific. On fraud, $\\tau=0.9$ is a touch lower on loss ($0.271$ vs $0.278$) while $\\tau=1.0$ is best on AUPRC ($0.925$). We did not tune $\\tau$ on the test set: $\\tau=1$ is our a priori default from the theory (exact odd-order cancellation, App. B.3), and AUPRC is the standard primary metric for a $6\\%$-positive task. The loss and AUPRC rankings differ only at the third decimal and never cross the ANE-vs-baseline gap; we will report both at every $\\tau$ so the trade-off is transparent.\n\n**Q1: Run a variance-fixed experiment isolating the third moment.** This is the experiment in W1 above: at fixed variance we sweep $\\mu_3'$ and ANE's skewness stays flat while Standard's climbs (synthetic table there), and on real data the variance-normalized $\\gamma_1$ shows the same (Fraud). We will report the per-task real-data version in the camera-ready.\n\n**Q2: Reconcile $\\tau=0.5\\approx\\tau=1.0$ with $\\tau=1$ being the key mechanism.** See W2 above, which answers this in full: the $c_n(\\tau)$ coefficient shows $\\tau<1$ damps rather than kills the odd-order terms; the $\\gamma_1$-vs-$\\tau$ table there is the requested fine-grained curve (with $\\mathcal M_3(\\xi)$ held 71–88\\% below Standard at every $\\tau$); and the downstream saturation is why $\\tau=0.5$ matches $\\tau=1.0$.\n\n**Q3: Total computational cost after accounting for reference-Hessian refresh, and scaling to larger models.** The refresh is not a cost driver: the reference is a large-batch snapshot resampled every $q_{\\mathrm{ref}}=10$ steps, $\\approx0.2$ ms on its own ($\\approx0.02$ ms/step amortized, $O(1/q_{\\mathrm{ref}})$), already folded into the numbers below and negligible next to the two-branch inverse-Hessian step. So the total is set by the HVP step: end-to-end (Table 2, with inner solve and amortized refresh) the overhead is $1.4$–$2.0\\times$ at $m{=}5$; isolating the inverse-Hessian step it is a roughly constant $2.4$–$3.1\\times$ (same table as RAQS W3), rising toward that ratio as $m$ grows. Hypergradient-only wall clock (ms/iter, CPU, 3 seeds), $m\\in\\{5,10,20,50\\}$:\n\n| Task | $m$ | StocBiO | SUSTAIN | ANE-SGD | ANE-VR |\n|---|---|---|---|---|---|\n| Housing | 5 | 1.2 | 1.6 | 3.1 | 3.9 |\n| | 10 | 2.1 | 3.6 | 6.2 | 7.3 |\n| | 20 | 4.0 | 6.3 | 12.1 | 13.8 |\n| | 50 | 9.7 | 15.6 | 29.4 | 35.1 |\n| Fashion | 5 | 1.1 | 1.9 | 2.9 | 3.2 |\n| | 10 | 2.0 | 2.6 | 5.7 | 6.1 |\n| | 20 | 3.8 | 6.5 | 11.0 | 14.7 |\n| | 50 | 9.0 | 14.7 | 27.1 | 31.5 |\n| Acrobot | 5 | 1.2 | 1.9 | 3.1 | 3.4 |\n| | 10 | 2.1 | 2.7 | 6.1 | 7.6 |\n| | 20 | 4.0 | 6.5 | 11.8 | 14.8 |\n| | 50 | 9.5 | 14.4 | 29.2 | 37.4 |\n| Fraud | 5 | 0.5 | 0.7 | 1.2 | 1.5 |\n| | 10 | 0.8 | 1.3 | 2.2 | 3.1 |\n| | 20 | 1.5 | 2.0 | 4.3 | 5.1 |\n| | 50 | 3.7 | 5.6 | 11.0 | 12.1 |\n\nANE-SGD is $2.4$–$3.1\\times$ StocBiO, roughly constant in $m$ (each method's HVP count is linear in $m$); ANE-VR is $2.8$–$3.9\\times$, close to ANE-SGD since the PAGE branch dominates. On model-size scaling: each matvec is linear in the parameter count $p$, and ANE adds one reference-Hessian application per Neumann factor. We never materialize $\\bar H$ ($O(p^2)$ storage) but apply it as a reference-batch HVP, or use the EMA reference already in the appendix, so ANE inherits the base method's per-parameter scaling and full-batch snapshots are not required at scale.\n\n**Q4: Which conclusions still hold for general matrix-valued, non-shared-eigenbasis noise?** The shared eigenbasis is only needed for the closed-form formulas, not for the method. Theorem 3.1 and Prop. 3.2 assume the scalar model $\\hat Hv=s_iHv$ so the variance, $\\mu_3'$, and $\\gamma_1$ come out in closed form. Everything ANE relies on is proved for arbitrary $A$ and $E_j$: the odd-order cancellation (Prop. 3.4), the $O(m^2\\rho^2)$-vs-linear-in-$\\rho$ error bound (Cor. 3.5), and the reference-sensitivity bound (Prop. 3.6) all use operator norms and a noncommutative telescoping identity, with no eigenbasis assumption. The real tasks already sit in this general setting: they use MLPs, so their stochastic Hessians are full dense matrices with no shared eigenbasis, and the cancellation and its bounds carry over as stated."
+ },
+ "createdAt": "2026-07-28T02:30:45.076Z",
+ "modifiedAt": "2026-11-18T17:19:45.434Z",
+ "url": "https://openreview.net/forum?id=6hdVJxlWcS&noteId=mPx7XiOdha",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/6hdvjxlwcs/notes/whmafhg0qo.json added

+++ b/reviews/openreview/6hdvjxlwcs/notes/whmafhg0qo.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "WhmAFHg0QO",
+ "replyTo": "IM2eWdGDFh",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We thank the reviewer for the careful reading and take the points in order. AC meta-review points addressed: AC1 (W1, W5), AC3 (W2, Q2), AC4 (W3, W4, Q3, Q4).\n\n**W1: Standardized skewness decays in $m$, but the vector diagnostic we plot is a different object, and it is the one that governs the experiments.** We report both because they answer different questions. In the scalar model of Thm 3.1 the estimator is a scalar $P_m$, and there standardized skewness $\\gamma_1=\\mathbb{E}[(P_m-\\mathbb{E}P_m)^3]/\\mathrm{Var}(P_m)^{3/2}$ is the usual asymmetry measure; by Thm 3.1(iii) it decays like $1/\\sqrt m$. That decay does not mean the asymmetry is shrinking: the third moment in the numerator grows with $m$, but the variance in the denominator grows faster once raised to the $3/2$ power, so the ratio drops. The estimator we actually run is vector-valued ($\\xi=\\hat v_{\\rm Neu}-v^\\star$), which has no single standardized skewness, so there we track the absolute proxy $\\mathcal M_3(\\xi)=\\mathbb{E}\\|\\xi-\\mathbb{E}\\xi\\|^3$ (Sec. 3.3), the same third moment without the variance in the denominator, so it grows. We use it because it upper-bounds the third moment in every direction (Sec. 3.3) and is the term that enters our error bound (Prop. 3.3, $\\|\\widehat G-G\\|^3\\lesssim\\|\\hat v-v^\\star\\|^3+\\cdots$), which is also the only part that depends on $m$. So this proxy is what feeds the hypergradient error, and it is what Figure 1(c) plots; its growth with $m$ and $\\kappa_g$ is our empirical Claim C1, as the reviewer notes. We will state the scalar-versus-vector distinction explicitly and relabel the panel so $\\gamma_1$ and $\\mathcal M_3$ are not conflated.\n\n**W2: Contraction of the mirrored branch under an approximate reference.** Prop. 3.6 controls the residual through the reference error $\\|\\bar H-H\\|/\\|H\\|$, which in practice stays within a few percent across training on every task. The contraction it assumes can be checked just as directly: at five checkpoints per run we apply the forward and mirrored depth-$m$ products to the true inner gradient $b$ and compare their per-factor rates. Averaged over the five, the mirrored branch matches the standard Neumann rate to within about $1\\%$, with no checkpoint off by more than $4\\%$, so mirroring does not change the contraction already present in the standard estimator.\n\n| task | $\\|\\bar H-H\\|/\\|H\\|$ | ANE vs. standard (avg) |\n|---|---|---|\n| Housing | 0.04–0.10 | +0% |\n| Fashion | 0.08–0.09 | +1% |\n| Acrobot | 0.03–0.04 | +1% |\n\nThis addresses the concern that Prop. 3.6's contraction is stronger than the noise assumptions and left unverified: mirroring does not meaningfully change standard Neumann's contraction factor, so ANE is stable wherever the estimator it replaces already is. We will add plots of the approximate-reference error to the appendix.\n\n\n**W3: Table 2 reports overhead only at $m{=}5$.** We agree a single point understates the cost at larger depth, so here is the full sweep. The $1.4$–$2.0\\times$ in Table 2 is for the whole outer iteration at $m{=}5$, where the shared inner solve dominates and dilutes the ratio; isolating just the inverse-Hessian-vector step gives a cleaner comparison, swept over $m$ below. Hypergradient-only wall clock (ms/iter, CPU, 3 seeds), for $m\\in\\{5,10,20,50\\}$:\n\n| Task | $m$ | StocBiO | SUSTAIN | ANE-SGD | ANE-VR |\n|---|---|---|---|---|---|\n| Housing | 5 | 1.2 | 1.6 | 3.1 | 3.9 |\n| | 10 | 2.1 | 3.6 | 6.2 | 7.3 |\n| | 20 | 4.0 | 6.3 | 12.1 | 13.8 |\n| | 50 | 9.7 | 15.6 | 29.4 | 35.1 |\n| Fashion | 5 | 1.1 | 1.9 | 2.9 | 3.2 |\n| | 10 | 2.0 | 2.6 | 5.7 | 6.1 |\n| | 20 | 3.8 | 6.5 | 11.0 | 14.7 |\n| | 50 | 9.0 | 14.7 | 27.1 | 31.5 |\n| Acrobot | 5 | 1.2 | 1.9 | 3.1 | 3.4 |\n| | 10 | 2.1 | 2.7 | 6.1 | 7.6 |\n| | 20 | 4.0 | 6.5 | 11.8 | 14.8 |\n| | 50 | 9.5 | 14.4 | 29.2 | 37.4 |\n| Fraud | 5 | 0.5 | 0.7 | 1.2 | 1.5 |\n| | 10 | 0.8 | 1.3 | 2.2 | 3.1 |\n| | 20 | 1.5 | 2.0 | 4.3 | 5.1 |\n| | 50 | 3.7 | 5.6 | 11.0 | 12.1 |\n\nAcross depths ANE-SGD stays at a fairly constant $2.4$–$3.1\\times$ StocBiO and SUSTAIN at $1.3$–$1.7\\times$, as expected since each method's HVP count is linear in $m$. ANE-VR is a little higher at $2.8$–$3.9\\times$, only modestly above ANE-SGD because at the real snapshot probabilities the cheap PAGE branch is taken most of the time. End-to-end overhead therefore climbs from the $m{=}5$ number toward these ratios as $m$ grows, and the camera-ready will replace the $m{=}5$-only report with this table.\n\n\n**W4: ANE-VR's role is to improve recursive-VR pipelines, and it does; ANE-SGD $\\approx$ ANE-VR is expected from the mechanism, not a sign of redundancy.** The controlled comparison for ANE-VR is against SUSTAIN, since both carry recursive variance reduction and differ only in the antithetic inverse approximation. ANE-VR wins on every task: Housing loss $0.111$ vs $0.147$ ($R^2$ $0.60$ vs $0.39$); Fashion $0.504$ vs $0.542$ ($88.7\\%$ vs $86.9\\%$); Acrobot $0.310$ vs $0.325$ ($R^2$ $0.20$ vs $0.16$); Fraud $0.285$ vs $0.342$ (AUPRC $0.923$ vs $0.910$). That isolates skewness reduction inside an otherwise identical VR wrapper, which is exactly the sense in which ANE-VR is a contribution: ANE drops into an existing recursive-VR method and strictly improves it.\n\nThat ANE-VR then tracks ANE-SGD closely (all gaps $\\le0.017$, within or near one standard deviation) fits the mechanism rather than showing redundancy: ANE already removes the within-estimate odd-degree term, so the across-iteration fluctuation recursive VR additionally targets is only a small residual on these tasks. We recommend ANE-SGD as the simpler default when no VR wrapper is in use, and ANE-VR when one already is; either way the antithetic step delivers the gain. We do not credit the small ANE-SGD/ANE-VR differences to VR (on Fashion and Fraud ANE-VR is in fact marginally behind, well within noise); the honest reading is that once skewness is cancelled, recursive VR neither helps nor hurts much here, and would help only when substantial across-iteration variance remains.\n\n**W5: No iterate-level convergence guarantee, only estimator-level bounds.** We can lift the estimator-level result to an iterate-level rate using only assumptions already in the paper, with no new smoothness condition. Writing the hypergradient's conditional squared bias, variance, and centered third moment as $\\bar r^2,\\bar\\sigma^2,\\overline M_3$, a second-order descent lemma (using the $L_2$-Lipschitz Hessian of Assumption 4(ii)) telescopes, for $\\alpha\\le 1/(4L_F)$, to\n$$\\begin{aligned}\n\\frac1T\\sum_{t<T}\\mathbb E\\|\\nabla F(\\lambda_t)\\|^2 \\&\\le\\ \\frac{2(F(\\lambda_0)-F_\\star)}{\\alpha T} + \\tfrac52\\bar r^2 + L_F\\alpha\\bar\\sigma^2 + \\tfrac{L_2\\alpha^2}{3}\\overline M_3,\\\\\\\\[4pt]\n\\overline M_3 &= \\begin{cases}O(\\rho^3) & \\text{standard Neumann}\\\\\\\\ O(\\rho^6) & \\text{ANE.}\\end{cases}\n\\end{aligned}$$\nAlmost everything in this bound is shared by the two estimators. Under an exact reference ANE and standard Neumann are both unbiased to $\\mathcal N_m$ (Prop. 3.4), so they have the same $\\bar r^2$ and $\\bar\\sigma^2$ and differ only in $\\overline M_3$: with $\\rho$ the per-factor noise scale, the Neumann-induced third moment is $O(\\rho^3)$ for standard Neumann but $O(\\rho^6)$ for ANE, since ANE's deviation from $\\mathcal N_m$ starts at $O(\\rho^2)$ rather than $O(\\rho)$ (Cor. 3.5). The condition $\\rho<1$ that makes this an improvement is not something ANE adds: the stochastic Neumann series only converges when each factor is contractive, so $\\rho<1$ is already required for standard Neumann (and hence StocBiO/SUSTAIN) to be valid at all. Wherever the baseline estimator converges, then, $\\rho^6<\\rho^3$, so ANE's third moment is strictly smaller rather than merely relabeled. (An approximate reference adds a residual $\\|R\\|$, but it enters only linearly by Prop. 3.6 and stays within a few percent across training by W2, so it does not overturn this gain.) ANE-VR composes with the recursive wrapper; the full statement, assumptions, and proof go in the camera-ready.\n\n**Q1: What are the per-task $\\kappa_g$ and $\\mu_3'$ values?** App. B.5 ties to the bimodal per-sample curvature $\\sigma_i''$, with active fraction $p$:\n$$\\mu_3'\\propto -\\tfrac1{b^2}\\,pc^3(1-p)(1-2p),$$\nnonzero whenever $p\\notin\\{0,\\tfrac12,1\\}$. The active fractions are all away from $\\tfrac12$ ($p\\approx0.8$ Housing, $0.21$ Acrobot, $0.1$ Fashion, $0.06$ Fraud), so every task has nonzero $\\mu_3'$; Housing and Acrobot additionally have a reduced effective sample count that raises $\\kappa_g$. We report the standardized ratio $\\hat\\mu_3'/\\hat\\sigma^3$ rather than raw $\\hat\\mu_3'$ because the raw value depends on the curvature units ($b,c$ above), which differ by task, whereas the ratio cancels that scale and is directly comparable. Measured directly:\n\n| Task | $\\hat\\kappa_g$ | std. skew $\\hat\\mu_3'/\\hat\\sigma^3$ |\n|---|---|---|\n| Housing | $1.8\\times10^8$ | $1.17$ |\n| Fashion | $4.7\\times10^7$ | $0.05$ |\n| Acrobot | $6.6\\times10^7$ | $-0.07$ |\n| Fraud | $5.4$ | $6.42$ |\n\nThe table confirms App. B.5: Housing and Acrobot are the most ill-conditioned, with Housing showing moderate skew, while Fraud is well-conditioned with the strongest skew. Fashion's and Acrobot's small standardized skew here reflects the diagnostic probing a single random direction, which rarely aligns with their task-specific curvature asymmetry.\n\n**Q2: Verify the mirrored branch's contraction empirically.** See W2 above.\n\n**Q3: Per-iteration wall-clock at each task's actual $m$.** See W3 above. The reference-snapshot cost (measured $0.2$–$0.25$ ms, amortized over $q_{\\mathrm{ref}}=10$) is not a driver of the overhead.\n\n**Q4: When does ANE-VR add value over ANE-SGD?** See W4 above.\n\n**Limitations.** Both points are already covered above: Prop. 3.6's contraction is checked empirically in W2, and the symmetric-noise ($\\mu_3'=0$) negative control is in qj4Y's W1 (also AXL7's Q1), where ANE gives no benefit or harm."
+ },
+ "createdAt": "2026-07-28T02:26:14.731Z",
+ "modifiedAt": "2026-11-18T17:19:45.896Z",
+ "url": "https://openreview.net/forum?id=6hdVJxlWcS&noteId=WhmAFHg0QO",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/6hdvjxlwcs/submission.json added

+++ b/reviews/openreview/6hdvjxlwcs/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "6hdVJxlWcS",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 26379,
+ "url": "https://openreview.net/forum?id=6hdVJxlWcS",
+ "license": "CC-BY-4.0"
+}

versions/v_dyt2r57y.json added

+++ b/versions/v_dyt2r57y.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-05-04",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 26379,
+ "url": "https://openreview.net/forum?id=6hdVJxlWcS",
+ "reviews": "openreview/6hdvjxlwcs",
+ "evidence": [
+ "https://openreview.net/forum?id=6hdVJxlWcS"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=6hdVJxlWcS",
+ "evidence": [
+ "https://openreview.net/forum?id=6hdVJxlWcS"
+ ]
+}