potentialpaper

A Steerable Deep Network for Model-Free Diffusion MRI Registration

Update NeurIPS 2026 submission 16OdjrftpZ: 6 notes

@openreview[bot] · 2026-11-24 15:44 UTC · 80b2af822554 ·

Evidence

reviews/openreview/16odjrftpz/notes/ctrksbjidw.json added

+++ b/reviews/openreview/16odjrftpz/notes/ctrksbjidw.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "CtRKSBJIdw",
+ "replyTo": "oX1l48uCc6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer gy17",
+ "content": {
+ "comment": "I thank the authors for the thorough rebuttal and for completing the requested ablations. All five of my concerns are addressed substantially.\n\nThe learned rotation variant was fine-tuned from the converged finite-strain model, so the comparison is confounded by training protocol. Please state this clearly. Note also that finite strain edges out the learned field on Dice and HD. The trade-off should be presented as such rather than as a uniform win.\n\nPlease state the locality axiom and the strict-enlargement result as a numbered proposition with proof, as promised.\n\nI am maintaining my rating of 4."
+ },
+ "createdAt": "2026-08-03T01:40:39.320Z",
+ "modifiedAt": "2026-11-19T17:20:14.388Z",
+ "url": "https://openreview.net/forum?id=16OdjrftpZ&noteId=CtRKSBJIdw",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/16odjrftpz/notes/gxm3uoufyh.json added

+++ b/reviews/openreview/16odjrftpz/notes/gxm3uoufyh.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "gxm3UouFYH",
+ "replyTo": "CtRKSBJIdw",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you",
+ "comment": "Thank you for the careful follow-up and for confirming that all five of your concerns have now been substantially addressed.\n\nWe agree that the training protocol is important context for interpreting the ablation. As noted, the learned-$T$ variant was fine-tuned from the converged finite-strain model to provide a suitable initialization for the more flexible learned rotation field. We will state this procedure explicitly in the revised manuscript and present the HCP ablation results as a trade-off between the two reorientation strategies. The relative benefits of learned reorientation on datasets with greater reorientation complexity remain an important direction for future evaluation.\n\nFinally, we will state the locality axiom and the strict-enlargement result as a numbered proposition with a complete proof in the revised manuscript, as promised."
+ },
+ "createdAt": "2026-08-03T18:40:29.898Z",
+ "modifiedAt": "2026-11-19T17:20:14.154Z",
+ "url": "https://openreview.net/forum?id=16OdjrftpZ&noteId=gxm3UouFYH",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/16odjrftpz/notes/mmvikahz43.json added

+++ b/reviews/openreview/16odjrftpz/notes/mmvikahz43.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "mMviKAHz43",
+ "replyTo": "yI2dZ2y24g",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to the Area Chair",
+ "comment": "We thank the Area Chair for their careful synthesis of the reviews, and we appreciate their recognition of the proposed framework's principled geometric formulation.\n\n> **Clarifying the practical advantages of the proposed framework.**\n\nOur updated native-resolution experiments show that the proposed method achieves statistically significant improvements over DDMReg and `mrregister` in bundle Dice, and over DDMReg in bundle Hausdorff distance. See our initial responses to Reviewers **gy17** and **zT1d** for the paired statistical comparisons. More generally, our framework operates directly on the measured diffusion signal (on $\\mathbb{PQ}$-space) and is therefore agnostic to the choice of downstream diffusion model. As discussed in the next point, this representation-agnostic design substantially shortens the end-to-end registration workflow.\n\n> **Supporting the claimed computational advantages.**\n\nWe conducted an end-to-end wall-clock runtime comparison that includes each method's required preprocessing. On average, our method required **5.37 s** per fixed-moving pair, compared with **481.36 s** for MVCReg, **611.49 s** for DDMReg, and **1321.75 s** for `mrregister`, yielding an **89.6×** speedup over the next-fastest method. The experiment demonstrates that the speedup is overwhelmingly due to bypassing costly CPU-bound preprocessing routines that remain standard in existing dMRI analysis pipelines. Thus, our approach substantially shortens the end-to-end registration workflow while remaining independent of downstream derived representations. Kindly refer to the timing breakdown provided in our initial responses to Reviewers **gy17**, **Qkm2**, and **zT1d**.\n\n> **Strengthening the empirical analysis.**\n\nWe are actively conducting the requested ablation studies to better isolate the contributions of the method's key design choices. We will post the key results here as soon as they are available and provide the corresponding experimental details in our reviewer responses.\n\n> **Supporting the geometry-specific claims.**\n\nTo directly evaluate preservation of the underlying diffusion geometry, we added three targeted test metrics: (1) fODF angular correlation coefficient, (2) matched peak angular error, and (3) diffusion tensor overlap. Our method achieved the strongest performance across all three metrics, providing direct quantitative evidence for our geometry-aware formulation beyond what can be inferred indirectly from white-matter proxy measures such as bundle Dice. The complete evaluation protocol and results are provided in our initial responses to Reviewers **Qkm2** and **zT1d**. Furthermore, we tempered the claim associated with our qualitative evidence in response to Reviewer **zT1d**'s valid concern.\n\n> **Clarifying implementation details and theoretical assumptions.**\n\nThe multi-shell formulation is clarified in our initial response to Reviewer **gy17**. The baseline tuning protocol is detailed in our initial response to Reviewer **zT1d**. The locality assumption and its relationship to our proposed space of feasible alignments are addressed in our initial response to Reviewer **gy17**."
+ },
+ "createdAt": "2026-07-29T03:23:02.735Z",
+ "modifiedAt": "2026-11-19T17:20:14.290Z",
+ "url": "https://openreview.net/forum?id=16OdjrftpZ&noteId=mMviKAHz43",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/16odjrftpz/notes/opnu51j9wq.json added

+++ b/reviews/openreview/16odjrftpz/notes/opnu51j9wq.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "OPNU51j9wQ",
+ "replyTo": "Byy4HD39St",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Follow-up: Requested Ablations",
+ "comment": "We thank the reviewer for their patience. We have now completed MMD-versus-MSE and fiber-reorientation ablations on the native-resolution HCP data used throughout our rebuttal.\n\n### MMD versus MSE comparison\n\nWe amended the original loss comparison by additionally reporting Hausdorff distance and the standard deviation across three training runs. Both variants used the same backbone, differing only in the similarity objective.\n\n| Loss | Bundle Dice ↑ | Bundle HD (mm) ↓ |\n|---|---:|---:|\n| MSE | 0.7828 ± 0.0021 | 10.44 ± 0.17 |\n| MMD | **0.7917 ± 0.0015** | **10.02 ± 0.12** |\n\nThese results confirm that the MMD objective provides a consistent improvement over a conventional MSE objective when registering raw diffusion signals directly. \n\n### Fiber-reorientation ablation\n\nWe also completed the requested reorientation ablation by comparing three variants:\n\n- no explicit fiber reorientation: $T(\\mathbf p)=I$,\n- finite-strain reorientation: $T(\\mathbf p)=\\operatorname{polar}(D\\varphi(\\mathbf p))$, and\n- learned fiber rotation: $T(\\mathbf p)=\\exp(\\widehat{\\omega(\\mathbf p)})$.\n\nWe report the same updated macrostructural and new microstructural metrics as in the white matter alignment analyses, computed as mean ± standard deviation over the 90 HCP test pairs.\n\n| Reorientation | Bundle Dice ↑ | Bundle HD (mm) ↓ | ACC ↑ | Peak error (°) ↓ | Tensor OVL ↑ |\n|---|---:|---:|---:|---:|---:|\n| None | 0.7840 ± 0.0261 | 10.44 ± 0.92 | 0.58 ± 0.01 | 26.18 ± 0.71 | 0.59 ± 0.01 |\n| Finite strain | **0.7979 ± 0.0142** | **10.08 ± 0.85** | 0.59 ± 0.01 | 24.91 ± 0.44 | 0.63 ± 0.01 |\n| Learned | 0.7940 ± 0.0115 | 10.14 ± 0.82 | **0.61 ± 0.01** | **22.93 ± 0.22** | **0.66 ± 0.01** |\n\nThe learned $T$ variant was initialized from the converged finite-strain model and fine-tuned with learned reorientation enabled. The ablation confirms that explicit fiber reorientation is important, as both reorientation variants outperform $T=I$, particularly on the orientation-sensitive metrics. Finite-strain reorientation achieves slightly stronger macrostructural alignment, as measured by bundle Dice and Hausdorff distance. One plausible explanation is that, because $T$ is fully determined by $D\\varphi$, the model must express both spatial and angular alignment through the deformation field $\\varphi$, which can favor bundle-level overlap. In contrast, the learned variant can distribute the alignment between $\\varphi$ and an independent rotation field $T$, yielding substantially better ACC, peak error, and tensor overlap while remaining competitive on macrostructural metrics. This suggests that the additional freedom in $T$ is used primarily to improve local diffusion-orientation correspondence rather than gross anatomical overlap.\n\nThese additional ablations will be incorporated into the revised manuscript together with the corresponding implementation details."
+ },
+ "createdAt": "2026-07-31T06:47:01.731Z",
+ "modifiedAt": "2026-11-19T17:20:14.259Z",
+ "url": "https://openreview.net/forum?id=16OdjrftpZ&noteId=OPNU51j9wQ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/16odjrftpz/notes/ox1l48ucc6.json added

+++ b/reviews/openreview/16odjrftpz/notes/ox1l48ucc6.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "oX1l48uCc6",
+ "replyTo": "BHqq6OtD9h",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Follow-up: Requested Ablation",
+ "comment": "We thank the reviewer for their patience. As promised, we have now completed requested ablations on the native-resolution HCP data used throughout our rebuttal.\n\n### MMD versus MSE comparison\n\nWe amended the original loss comparison by additionally reporting Hausdorff distance and the standard deviation across three training runs. Both variants used the same backbone, differing only in the similarity objective.\n\n| Loss | Bundle Dice ↑ | Bundle HD (mm) ↓ |\n|---|---:|---:|\n| MSE | 0.7828 ± 0.0021 | 10.44 ± 0.17 |\n| MMD | **0.7917 ± 0.0015** | **10.02 ± 0.12** |\n\nThese results confirm that the MMD objective provides a consistent improvement over a conventional MSE objective when registering raw diffusion signals directly. \n\n### Fiber-reorientation ablation\n\nWe also completed the requested reorientation ablation by comparing three variants:\n\n- no explicit fiber reorientation: $T(\\mathbf p)=I$,\n- finite-strain reorientation: $T(\\mathbf p)=\\operatorname{polar}(D\\varphi(\\mathbf p))$, and\n- learned fiber rotation: $T(\\mathbf p)=\\exp(\\widehat{\\omega(\\mathbf p)})$.\n\nWe report the same updated macrostructural and new microstructural metrics as in the white matter alignment analyses, computed as mean ± standard deviation over the 90 HCP test pairs.\n\n| Reorientation | Bundle Dice ↑ | Bundle HD (mm) ↓ | ACC ↑ | Peak error (°) ↓ | Tensor OVL ↑ |\n|---|---:|---:|---:|---:|---:|\n| None | 0.7840 ± 0.0261 | 10.44 ± 0.92 | 0.58 ± 0.01 | 26.18 ± 0.71 | 0.59 ± 0.01 |\n| Finite strain | **0.7979 ± 0.0142** | **10.08 ± 0.85** | 0.59 ± 0.01 | 24.91 ± 0.44 | 0.63 ± 0.01 |\n| Learned | 0.7940 ± 0.0115 | 10.14 ± 0.82 | **0.61 ± 0.01** | **22.93 ± 0.22** | **0.66 ± 0.01** |\n\nThe learned $T$ variant was initialized from the converged finite-strain model and fine-tuned with learned reorientation enabled. The ablation confirms that explicit fiber reorientation is important, as both reorientation variants outperform $T=I$, particularly on the orientation-sensitive metrics. Finite-strain reorientation achieves slightly stronger macrostructural alignment, as measured by bundle Dice and Hausdorff distance. One plausible explanation is that, because $T$ is fully determined by $D\\varphi$, the model must express both spatial and angular alignment through the deformation field $\\varphi$, which can favor bundle-level overlap. In contrast, the learned variant can distribute the alignment between $\\varphi$ and an independent rotation field $T$, yielding improved ACC, peak error, and tensor overlap while remaining competitive on macrostructural metrics. This suggests that the additional freedom in $T$ is used primarily to improve local diffusion-orientation correspondence rather than gross anatomical overlap.\n\nThese additional ablations will be incorporated into the revised manuscript together with the corresponding implementation details."
+ },
+ "createdAt": "2026-07-31T06:44:23.504Z",
+ "modifiedAt": "2026-11-19T17:20:14.281Z",
+ "url": "https://openreview.net/forum?id=16OdjrftpZ&noteId=oX1l48uCc6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/16odjrftpz/notes/yi2dz2y24g.json modified

+++ b/reviews/openreview/16odjrftpz/notes/yi2dz2y24g.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair yy8m",
"content": {
- "metareview": "The reviewers generally agree that this paper presents an interesting and principled approach to diffusion MRI registration by operating directly on raw diffusion signals rather than derived representations. The paper formulates registration in the native spatio-angular acquisition space using a geometric vector-bundle framework, instantiates the formulation with an SE(3)-equivariant network that jointly predicts spatial deformation and local fiber rotation, and introduces a self-supervised MMD-based registration objective. The theoretical formulation and geometric motivation are generally viewed as technically sound and constitute the primary strengths of the submission.\n\nHowever, several important questions remain before the paper can be strongly considered for acceptance. The rebuttal should primarily focus on the following issues:\n\n1. Clarifying the practical advantages of the proposed framework. While reviewers generally agree that the proposed formulation is elegant, the empirical results are not clearly superior to the strongest existing methods. \n2. Supporting the claimed computational advantages. The paper emphasizes that operating directly on raw diffusion signals avoids the overhead of constructing intermediate representations. Reviewers requested quantitative evidence supporting this claim. Please clarify the computational trade-offs relative to competing methods, including runtime, memory usage, or preprocessing cost where possible, and explain the practical implications of these differences.\n3. Strengthening the empirical analysis. Reviewers requested additional evidence supporting the proposed design choices, including more comprehensive ablations, statistical analysis of the reported improvements, and clarification of the contribution of key components such as the equivariant architecture, learned rotation field, and MMD loss. Please clarify these aspects and discuss the extent to which each component contributes to the overall performance.\n4. Supporting the geometry-specific claims. Several reviewers requested stronger evidence that the proposed framework preserves the underlying diffusion geometry and white matter structure, beyond standard registration metrics. Please clarify what evidence supports these geometry-specific claims and discuss the limitations of the current experimental validation.\n5. Clarifying implementation details and theoretical assumptions. Reviewers requested clarification regarding multi-shell handling, baseline tuning protocols, and several theoretical assumptions underlying the geometric formulation. Please clarify these points to improve reproducibility and strengthen the presentation."
+ "metareview": "The reviewers generally agree that this paper presents an interesting and principled approach to diffusion MRI registration by operating directly on raw diffusion signals rather than derived representations. The paper formulates registration in the native spatio-angular acquisition space using a geometric vector-bundle framework, instantiates the formulation with an SE(3)-equivariant network that jointly predicts spatial deformation and local fiber rotation, and introduces a self-supervised MMD-based registration objective. The theoretical formulation and geometric motivation are generally viewed as technically sound and constitute the primary strengths of the submission.\n\nHowever, several important questions remain before the paper can be strongly considered for acceptance. The rebuttal should primarily focus on the following issues:\n\n1. Clarifying the practical advantages of the proposed framework. While reviewers generally agree that the proposed formulation is elegant, the empirical results are not clearly superior to the strongest existing methods. \n2. Supporting the claimed computational advantages. The paper emphasizes that operating directly on raw diffusion signals avoids the overhead of constructing intermediate representations. Reviewers requested quantitative evidence supporting this claim. Please clarify the computational trade-offs relative to competing methods, including runtime, memory usage, or preprocessing cost where possible, and explain the practical implications of these differences.\n3. Strengthening the empirical analysis. Reviewers requested additional evidence supporting the proposed design choices, including more comprehensive ablations, statistical analysis of the reported improvements, and clarification of the contribution of key components such as the equivariant architecture, learned rotation field, and MMD loss. Please clarify these aspects and discuss the extent to which each component contributes to the overall performance.\n4. Supporting the geometry-specific claims. Several reviewers requested stronger evidence that the proposed framework preserves the underlying diffusion geometry and white matter structure, beyond standard registration metrics. Please clarify what evidence supports these geometry-specific claims and discuss the limitations of the current experimental validation.\n5. Clarifying implementation details and theoretical assumptions. Reviewers requested clarification regarding multi-shell handling, baseline tuning protocols, and several theoretical assumptions underlying the geometric formulation. Please clarify these points to improve reproducibility and strengthen the presentation.",
+ "final_justification": "I have read the authors’ response in full, including the subsequent experimental updates and the reviewer's final justifications. The response materially strengthens the submission and successfully addresses most of the issues raised in my initial meta-review. The reviewers reached a similar conclusion: one reviewer stated that all five of their concerns were substantially addressed, another increased their rating to Borderline Accept, and the third maintained a Borderline Accept rating after considering the explanations and additional evidence. Thus, all three reviewers ultimately recommended borderline acceptance.\n\nOn balance, the paper presents an original and principled formulation of raw-signal dMRI registration, with a network architecture and objective that are well aligned with the underlying geometry. The rebuttal converts several initially unsupported advantages into quantitatively supported ones, particularly regarding end-to-end runtime and orientation-sensitive alignment. The remaining weaknesses—most notably the incomplete isolation of equivariance, the confounded learned-rotation ablation, and limited validation across acquisition protocols and clinical populations—temper the strength of the contribution but do not outweigh its technical and practical value. I therefore recommend acceptance as a poster. \n\nBesides, the reference “Computing Large Deformation Metric Mappings via Geodesic Flows of Diffeomorphisms” should be flagged. The referenced paper exists, but its venue, volume, pages, and DOI are incorrectly reported. The authors should correct the bibliographic information in the final version."
},
"createdAt": "2026-07-21T11:28:09.440Z",
- "modifiedAt": "2026-11-18T15:24:26.204Z",
+ "modifiedAt": "2026-11-19T05:02:48.173Z",
"url": "https://openreview.net/forum?id=16OdjrftpZ&noteId=yI2dZ2y24g",
"license": "CC-BY-4.0"
}