Posterior Alternative Calibration in Ambiguous Inverse Problems
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:48 UTC · c69b73bc8c66 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,23 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "EKatBiU7g8"- }- ],- "title": "Posterior Alternative Calibration in Ambiguous Inverse Problems",- "authors": [- "Jing Qiao",- "Yiyang Guo",- "Hao Ye"- ],- "abstract": "Ambiguous inverse problems often admit multiple clean signals that are consistent\nwith the same observation. In such settings, a sampler should produce plausible\nreconstructions and allocate probability mass correctly across unresolved\nalternatives. We formalize this requirement as posterior alternative calibration\nand introduce mode coverage error (MCE), which compares posterior and sampler\nprobabilities over a finite set of specified alternatives. Averaging across alternatives\ncan preserve measurement consistency while producing a point outside\nthe set of valid posterior explanations. We establish sufficient conditions\nfor barycentric collapse in concentrated local sampling around conditional means\nand show that calibrated branch probabilities control MCE when samples remain\nwithin their selected alternatives. Experiments on Gaussian mixtures, ambiguous\ninpainting, and accelerated magnetic resonance imaging (MRI) demonstrate that\nmeasurement consistency and full alternative recall do not guarantee correct posterior\nprobability allocation. An evaluation with independently estimated target\nprobabilities further shows that observation-specific references materially affect\nsampler assessment. These results establish posterior alternative calibration as an\nevaluation axis complementary to reconstruction fidelity and quality within each\nalternative.",- "year": 2026,- "venue": "NeurIPS 2026",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "200eb734-1f34-4dd0-8a33-8ea1d96a30fd"}
paper.json added
+++ b/paper.json@@ -0,0 +1,13 @@+{+ "title": "Posterior Alternative Calibration in Ambiguous Inverse Problems",+ "authors": [+ "Jing Qiao",+ "Yiyang Guo",+ "Hao Ye"+ ],+ "abstract": "Ambiguous inverse problems often admit multiple clean signals that are consistent\nwith the same observation. In such settings, a sampler should produce plausible\nreconstructions and allocate probability mass correctly across unresolved\nalternatives. We formalize this requirement as posterior alternative calibration\nand introduce mode coverage error (MCE), which compares posterior and sampler\nprobabilities over a finite set of specified alternatives. Averaging across alternatives\ncan preserve measurement consistency while producing a point outside\nthe set of valid posterior explanations. We establish sufficient conditions\nfor barycentric collapse in concentrated local sampling around conditional means\nand show that calibrated branch probabilities control MCE when samples remain\nwithin their selected alternatives. Experiments on Gaussian mixtures, ambiguous\ninpainting, and accelerated magnetic resonance imaging (MRI) demonstrate that\nmeasurement consistency and full alternative recall do not guarantee correct posterior\nprobability allocation. An evaluation with independently estimated target\nprobabilities further shows that observation-specific references materially affect\nsampler assessment. These results establish posterior alternative calibration as an\nevaluation axis complementary to reconstruction fidelity and quality within each\nalternative.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}