Entropy Distribution as a Fingerprint for Hallucinations in Generative Models
Update NeurIPS 2026 submission yeXKhJ9iy3: 18 notes
@openreview[bot] · 2026-11-24 16:03 UTC · 133c26a278dc ·
reviews/openreview/yexkhj9iy3/notes/088txey7rx.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/088txey7rx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "088txEy7RX",+ "replyTo": "qa4O8SJcVu",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer rbqD",+ "content": {+ "comment": "Thank you for the thorough response. The matched-length subsampling, per-term ablation, and stratified results are exactly the analyses I was hoping to see.\n\nOn the length confound: I consider this convincingly addressed. The matched-pair result (CES 0.639 vs. length-only 0.502, with a mean length gap of only 0.02 tokens) together with the essentially unchanged partial correlations is clean evidence that the signal is not merely length. I'd encourage including these tables in the revision; the matched-pair analysis in particular is the persuasive one, since within length-quartiles the length-only baseline is near chance partly by construction.\n\nOn the framing: I appreciate the honesty of two findings in your response: that F₀(h̄) is rank-equivalent to LN entropy, and that the KS test was tried and set aside. Together these suggest the contribution is most accurately described as a calibrated tail (max) statistic added to LNE, rather than as using the full shape of the entropy distribution. I'm glad you plan to soften this. One question out of curiosity rather than as a request: since combined CES (0.636 ± 0.074) sits within a standard deviation of the max term alone (0.634 ± 0.070), do paired per-run comparisons show the combination helping consistently, or does the calibrated max carry most of the gain over LNE?\n\nOn stationarity: the ADF results and the positional entropy decline (0.93 -> 0.57 across quintiles) suggest the marginals aren't identical along a generation, so I read Assumption 1 as an idealization, which your response acknowledges. A sentence in the revision noting this measured trend alongside the assumption would pre-empt the same question from future readers.\n\nThese responses resolve my main methodological concern about the length confound, and I thank the authors for the effort invested in the new analyses. I am maintaining my score: the empirical case is now more solid, but the clarified relationship to LN entropy also narrows the framing of the contribution. I remain positive about the paper in its honestly reframed form."+ },+ "createdAt": "2026-08-01T05:56:43.192Z",+ "modifiedAt": "2026-11-19T16:41:54.888Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=088txEy7RX",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/3fsaqkacpm.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/3fsaqkacpm.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "3FSAQkACpm",+ "replyTo": "QDNSXIJZAy",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response To Reviewer's Comments (Part II)",+ "comment": "3. **Calibration and computation cost.** A calibration phase is intrinsic to CES, but we note that any method that does not pre-specify a threshold needs calibration when applied to new models. The key point is that CES requires one fixed calibration stage, after which each new query costs *exactly one* model generation—no additional samples, judge calls, NLI models, or trajectory comparisons. As Table 1 shows, only $\\sim 2$% of samples are needed to calibrate. Entropies are computed together with the answer and are cheap (a few milliseconds even for probability vectors of size $10^6$), and building the reference CDF is fast since entropies are just real numbers. The supervised variant adds a one-time judging cost on calibration data (unlike, e.g., KLE, which continuously calls LLMs), while the unsupervised variant, which performs consistently well, needs no labels at all. At test time we use only the mean and maximum token entropy, both cheap to compute. CES is thus very practical: as fast as any single-trajectory method, yet comparable to or sometimes better than multi-trajectory methods and ones using model internals. We will describe these costs in more detail in the revision.\n\n4. **Conditional independence.** We agree the entropies are not strictly independent in the experiments, and we do not claim this (see the paragraph below Assumption 1 in the paper). Independence is a simplifying assumption for deriving clean theory, while empirically the method only needs stable separation between calibrated faithful summaries and test summaries. We nonetheless expect the entropies to be only *weakly* dependent, for the following reason: although tokens are highly correlated (the next token depends on prior context), the token entropy conveys much coarser information—how certain the model is about the next token. Since information about \"which token\" will appear is irrecoverably lost once entropy is computed, dependence on context (and the past) is correspondingly weakened, so the token *entropies* (unlike the tokens themselves) are expected to be weakly dependent in practice. As an illustrative toy example, if $X_1,\\dots,X_n$ share a common latent factor via $X_i=\\sqrt{\\rho}\\,Z+\\sqrt{1-\\rho}\\,\\varepsilon_i$ with $Z,\\varepsilon_i\\overset{iid}{\\sim}\\mathcal N(0,1)$, then the transformation $X_i-\\bar X$ cancels the shared $Z$ exactly, leaving only idiosyncratic terms. We support this intuition in Appendix E.3: those experiments are intended to measure the *extent* of dependence rather than rule it out, and, being based on autocorrelation, they show the token entropies have low *linear* dependence. General nonlinear dependence is harder to rule out, as the reviewer correctly notes (e.g., $X=Y^2$ with uncorrelated but dependent variables); we are happy to test specific forms of dependence on our data if the reviewer has suggestions, and leave a detailed treatment and its consequences for detector design to future work, which we will outline in the revision.\n\n5. **Experimental presentation.** We apologize for the limited discussion in the experiments section and will expand the implications and clarify details in the main text as space permits (the appendix also answers many follow-up questions a reader would have, which we can expand on). The Friedman/Nemenyi analysis is a standard method for establishing the significance of method *ranks*, where cross-dataset accuracy comparisons may not be immediate; we will add details in the appendix, refer to [1] and example uses [2,3,4], and specify that the pairwise comparisons are on accuracy. We will also add a description of the KS test: a two-sample KS test checks whether samples from two sources come from the same underlying distribution, and Fig. 2b reports the KS statistic between the hallucinated and faithful distributions, showing they differ. More broadly, we agree that describing what each reported metric conveys aids readers, and will add this. We thank the reviewer for helping us improve our exposition.\n\n[1] Demšar, Janez. \"Statistical comparisons of classifiers over multiple data sets.\" Journal of Machine learning research 7.Jan (2006): 1-30. \n[2] Han, Songqiao, et al. \"Adbench: Anomaly detection benchmark.\" Advances in neural information processing systems 35 (2022): 32142-32159. \n[3] Ma, Jiabo, et al. \"A generalizable pathology foundation model using a unified knowledge distillation pretraining framework.\" Nature Biomedical Engineering 10.3 (2026): 545-564. \n[4] Ye, Han-Jia, Si-Yang Liu, and Wei-Lun Harry Chao. \"A closer look at TabPFN v2: Understanding its strengths and extending its capabilities.\" Advances in Neural Information Processing Systems 38 (2026): 135605-135637."+ },+ "createdAt": "2026-07-28T21:06:48.692Z",+ "modifiedAt": "2026-11-19T16:41:55.128Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=3FSAQkACpm",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/chudchks2h.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/chudchks2h.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "chUdChKS2h",+ "replyTo": "vU7pbJTk2j",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer's Comments (Part I)",+ "comment": "We thank the reviewer for the careful, constructive reading. Length-sensitivity and distributional robustness are integral to CES and we have stress-tested both below; we especially thank the reviewer for prompting a closer look at the max–length relationship. One framing point up front: both *length-normalized (LN) predictive entropy* and *length-only* (Ref.[16] in paper) are already baselines in our comparisons (called \"LN Entropy\" and \"Gen. Length\"), so CES is evaluated on equal footing and any pure length signal is available to the baselines too. All experiments below will be added, with explanations, to the revision.\n\n*Responses to limitations.*\n\n1. **Sensitivity to generation length.** We agree an unnormalized maximum grows with length and that Eq. (4) constrains individual tokens, not the maximum. But this happens for *both* faithful and hallucinated samples, and CES retains discriminatory power even asymptotically as long as the faithful and hallucinated means differ. This is because normalization occurs *implicitly* by passing $h_{\\max}$ through $F_0$, as the reviewer hinted. Concretely, if the faithful max-entropy support $\\zeta_0$ is below the hallucinated $\\zeta_1$ (supported by Fig. 2a), then for short generations $F_0(h_{\\max})$ is expected to be smaller for faithful than for hallucinated ($F_0$ being monotone). Asymptotically $F_0(h_{\\max})\\to1$ for both (since $1=F_0(\\zeta_0)\\le F_0(\\zeta_1)$), so CES reduces to $F_0(\\bar h)$; but since $\\bar h\\to\\mu_0$ (faithful) and $\\to\\mu_1$ (hallucinated) exponentially fast (Hoeffding), CES still separates the two. Thus CES judiciously combines the max (useful for short generations, where the mean is unreliable) with the mean (useful for long generations, where the mean converges). This is formalized in Theorem 2, where the TPR and FPR converge exponentially fast in generation length to $1$ and $0$ respectively, for appropriate parameters. A natural future extension for long generations is to use quantiles instead of the maximum (the max is just the $100$-quantile) while retaining the max for short ones.\n\n2. **Scope of the central theorem.** Yes, Theorem 1 concerns consistent estimation of the *reference* $F_0$ (and Eq. (4) is used in this regard), not the per-generation decision. The per-generation guarantees (TPR/FPR) are given by Theorem 2.\n\n3. **Length-stratified check.** In addition to Fig. 8 in the paper, we computed length-stratified AUROC, splitting samples into within-run generation-length quartiles (mean $\\pm$ std across the 48 open-weight model–dataset runs; \"Hall. frac.\" is the hallucinated fraction per bin):\n\n Table 2:\n\n | Length bin | CES AUROC | Gen. length AUROC | Hall. frac. |\n |---|:---:|:---:|:---:|\n | Q1 (3–13 tokens) | $0.638 \\pm 0.122$ | $0.513 \\pm 0.082$ | $0.318 \\pm 0.195$ |\n | Q2 (13–18 tokens) | $0.641 \\pm 0.110$ | $0.504 \\pm 0.050$ | $0.337 \\pm 0.206$ |\n | Q3 (18–27 tokens) | $0.646 \\pm 0.092$ | $0.506 \\pm 0.064$ | $0.377 \\pm 0.217$ |\n | Q4 (27–119 tokens) | $0.621 \\pm 0.088$ | $0.514 \\pm 0.072$ | $0.380 \\pm 0.193$ |\n\n CES performance is stable across strata and exceeds, in average, Gen. length (length-only) AUROC (near chance) in every bin, so CES carries signal beyond length.\n\n The lengths are stratified according to the quantiles. For the revised manuscript, we will ensure that the classes are length-balanced in the bins we used. \n\n4. **Serial-dependence and the detector.** Section 4.1 and Appendix E.4 test our key assumption—that the faithful and hallucinated entropy distributions differ. The KS test was our original candidate, but it needed relatively long generations and introduced numerical/algorithmic challenges, which motivated the CES-based test (also refer to our answer to question 1 of Reviewer fJ1W). We still report KS results for the interested reader.\n\n5. **Non-stationarity along a generation.** We checked stationarity with the Augmented Dickey–Fuller test (null $=$ non-stationarity/unit root for AR process). Averaged across 10 models, $75.3\\pm12.2\\%$ of series are stationary (faithful $76.5\\%$, hallucinated $74.0\\%$ on average). We do see the early-token effects the reviewer notes but no other clear pattern: the Spearman correlation between relative position and entropy is significant on $73/80$ (model, dataset) pairs, with median $\\rho=-0.139$ (mean $-0.120$), and mean entropy falls from $0.929$ in the first quintile to $0.574$ in the last. We suspect the model formulates a more \"creative\" opening statement (higher entropy) before lower-entropy factual content follows. Additional details and disaggregated values will be included in the revision.\n\n(Responses to limitation 6 and questions 1-5 are continued in the next comment due to 5000 character limit)"+ },+ "createdAt": "2026-07-28T21:08:18.778Z",+ "modifiedAt": "2026-11-19T16:41:55.090Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=chUdChKS2h",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/csoctjoq8z.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/csoctjoq8z.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "csocTjOQ8Z",+ "replyTo": "fp8kJoNJoD",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to follow-up questions (Part II)",+ "comment": "3. The setting we are considering is as follows. We have access to a judge (e.g., an LLM, a human expert) during the calibration phase to generate labels, which is assumed to be a costly process. During test time, one needs to decide whether or not a model is hallucinating *per generation* accurately and efficiently. Since it is costly to query an LLM judge or human expert for every generation, we avoid the use of a judge during test time. Alternatively, if one considers the LLM judge or human expert as the ground truth, which is standard practice, we cannot assume access to it during test time. CES (supervised) was designed to statistically summarize the behaviour of the judge (captured by the calibration distribution) and then use the summary during test time, which is very efficient. An important additional finding of our study is that if the model used to generate the responses only infrequently hallucinates, we can directly use the entropy distribution without any labels to perform as well as the supervised variant.\n \n This has been summarized in Section 3 of our paper: \"Such an oracle, for example, can be a human expert who determines whether a given input-output pair is a hallucination, or it could be an LLM judge that does the same. While an oracle could directly label hallucinations, it is typically costly or unavailable during production. We therefore seek to capture the decisions of the oracle statistically with high probability and low computational overhead.\" We will clarify this better in our main text or in the appendix according to the availability of space.\n\n4. Expanding on our previous answer in point (6), for obtaining the reference distribution for CES (unsup), for every model and dataset, we compute the token entropy distribution over the generations of the model given the inputs/questions (from the chosen dataset). We do **not** filter the distribution based on labels (which generations are hallucinations vs. faithful). We will add a separate algorithm similar to Algorithm 1 to clarify this in the revised manuscript, and we apologize if the presentation was unclear. We would like to point out that, as noted in the response to Q2 of Reviewer 1YLT, only a small amount of calibration data ($\\sim2$%) is required for constructing this reference CDF even for the unsupervised method.\n\n5. Most of our experiments compute the AUROC because computing thresholds fairly across all methods is challenging. For the experiments where we compute the accuracy, we used the second option of maximizing Youden's $J$ for selecting the threshold. We will clarify this in the paper and thank the reviewer for highlighting this."+ },+ "createdAt": "2026-08-03T18:30:16.072Z",+ "modifiedAt": "2026-11-19T16:41:54.917Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=csocTjOQ8Z",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/d3iwch0kql.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/d3iwch0kql.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "d3iwch0kql",+ "replyTo": "hyzpwLaSMZ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer's Comments (Part I)",+ "comment": "We thank the reviewer for the detailed reading and for thoughtful questions on the construction and implementation of CES. We answer them below.\n\n1. **KS-test underperformance.** We apologize for not expanding on the KS test and will add details in the appendix (and the main text as space permits). A two-sample KS test is a standard statistical test of whether two samples come from the same distribution, based on the KS statistic $d_{KS}(\\hat F_0,\\hat F_1)=\\sup_x|\\hat F_0(x)-\\hat F_1(x)|$ (up to normalization), i.e. the largest gap between the two empirical CDFs. We found it underperforms in the short-generation regime: applied to a single answer, a two-sample KS test has only as many samples as there are generated tokens, and many QA answers span just a few to a few dozen tokens, so the per-response empirical CDF is noisy. CES instead uses a reference CDF calibrated from many samples, together with two test-time summaries (the mean and maximum entropy) that are more stable for short generations while still capturing global and tail behavior.\n\n2. **Motivation for mean and max.** Short test-time generations make the per-response empirical CDF unreliable (Q1), which motivates using stable scalar summaries instead. We use two: the mean entropy, already a strong known signal, and the maximum entropy, which captures localized uncertainty spikes. Both are first mapped through the reference CDF $F_0$, making them comparable across models and datasets, and then combined via their geometric mean. Thus, although CES is a scalar, it is built from *calibrated* distributional summaries rather than a raw mean or maximum, which distinguishes it from prior single-scalar detectors. We also searched over many combinations of the main summary statistics and found the 2-way geometric mean outperformed every 3-way combination (Appendix E.7).\n\n3. **Unsupervised vs. supervised.** The two variants are essentially tied, consistent with our robustness-to-contamination checks, so neither consistently dominates. In a post-hoc split-calibration check on our local subset, held-out supervised CES is $0.632\\pm0.082$ and held-out unsupervised CES is $0.633\\pm0.082$, a negligible difference. Where the unsupervised reference is slightly better, a plausible reason is that it draws on a larger calibration pool with better upper-tail coverage; the supervised reference, built only from judged-faithful generations, can be smaller and more concentrated, so its ECDF saturates for high-entropy test generations. This small gain in tail resolution and estimation stability can outweigh the mild contamination from including all generations. The practical takeaway is that the two are essentially tied, and the unsupervised variant attains this without any judge-label cost.\n\n4. **Hallucination labels already known.** We agree CES (supervised) must be interpreted carefully when the same samples are used for calibration and evaluation, and we will clarify this. Two points mitigate the concern. First, only a very small fraction of samples is needed to calibrate: a random $\\sim 2$% of the data reaches the same AUROC as using all of it (Table 1 in our response to Q2 of Reviewer 1YLT). Second, the calibration-test split experiment (in our response to Q2(ii) of Reviewer 1YLT) explicitly shows that our method generalizes to unseen data. Importantly, CES (unsupervised), which performs on par with the supervised variant (Q3), uses no judge labels at all, so the concern does not apply to it.\n\n5. **Using the judge directly.** Using GPT-4.1-nano directly as the test-time detector is a different resource setting, as it requires a judge call for every query and draws on the same source as the evaluation labels. CES is designed precisely to avoid test-time judge calls: the judge is used only to produce evaluation labels and, in CES (supervised), to form an oracle calibration reference; CES (unsupervised) uses no judge labels for calibration. We will clarify this distinction in the revision.\n\n6. **Value of $\\gamma$.** The parameter $\\gamma$ is a theoretical contamination parameter, not something tuned in experiments. The unsupervised empirical CDF is computed by simply pooling the token entropies of all calibration generations, regardless of correctness labels, and hence, no judge and no tuning are required. CES (unsup) then evaluates this CDF at the mean and maximum entropy of each test generation. In Appendix E.8 we vary contamination synthetically and observe minimal effect on the estimator, consistent with the robustness of the unsupervised variant.\n\n(Responses to the final question is continued in the next comment due to 5000 character limit)"+ },+ "createdAt": "2026-07-28T21:11:40.816Z",+ "modifiedAt": "2026-11-19T16:41:55.088Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=d3iwch0kql",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/fdtlmq9qps.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/fdtlmq9qps.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "fDtlmq9QPS",+ "replyTo": "hyzpwLaSMZ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer fJ1W",+ "content": {+ "title": "Comment to Author Response",+ "comment": "Thank the authors for the responses. I have some follow-up questions.\n\n1. **Motivation for mean and max.** According to the response, it seems mean and max capture different signals, and that's why you want to use them both. I wonder if you have ever tried to use mean only or max only? Additionally, my concern is still there: I wonder why you use this particular form—geometric mean—to combine them, instead of using some other choices such as arithmetic mean? It seems this is not a principled choice; instead, it is an **intuitive** choice.\n\n2. **Unsupervised vs. supervised.** The generalization to unseen data addresses this concern. But according to the response, it seems my original understanding is correct?—**(1) CES (sup) uses part of the evaluation data as calibration data; (2) the hallucination labels for all samples, derived using GPT-4.1, are already known in CES (sup)**. I don't think this follows the standard test pipeline, where evaluation data should not be leaked. If (1) and (2) align with the descriptions in the submission, then I think those parts and the corresponding experiments should be revised.\n\n3. **Using the judge directly.** I am a bit confused about when we can assume access to GPT-4.1-nano and when we cannot. I wonder why we can use GPT-4.1-nano during the process within CES (sup), and why we cannot use it directly to get the hallucination predictions.\n\n4. New question: What is the source of calibration data for CES (unsup)?\n\n5. **Threshold selection and table formatting.** ```\"For a binary decision for deployment, a threshold can be chosen on a held-out validation set, by fixing a desired false-positive rate under the calibration reference, or by maximizing Youden's \n when labels are available.\"``` I wonder which desired false-positive rate you set in the experiments."+ },+ "createdAt": "2026-07-30T22:53:55.992Z",+ "modifiedAt": "2026-11-19T16:41:54.894Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=fDtlmq9QPS",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/fp8kjonjod.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/fp8kjonjod.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "fp8kJoNJoD",+ "replyTo": "orxUs81pj5",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to follow-up questions (Part I)",+ "comment": "We thank the reviewer for the follow-up questions, and we have answered them below.\n\n1. We thank the reviewer for suggesting other choices. Yes, we have tried mean or max alone, as well as other quantities like median, $25$% and $75$% quantiles. We considered several combinations of these measures (including mean and max alone), and *detailed ablation studies are given in Appendix E.7 and Fig. 9*. We rank all variants by average rank across 80 experiments, and find that the geometric mean of mean and max is the best combination.\n\n As the reviewer pointed out, there are several combinations one can consider beyond the geometric mean (GM). In principle, there are *infinitely many ways* to combine the mean and max signals, and we therefore *require theoretical or intuitive insights to restrict the search space*. Nevertheless, as per the reviewer's suggestion, we have now performed the ablation studies with the arithmetic mean (AM). In our experiments, we find that the AUROCs of both are well-aligned, and over 80 dataset-model pairs, we find that on average, GM AUROC $=0.653\\pm0.069$ vs. AM AUROC $=0.653\\pm0.068$.\n\n We thank the reviewer for this suggestion, as we believe such ablations strengthen our study and we will include them in the final manuscript. To summarize, *while our method was developed based on intuitive and theoretical insights, we support them with detailed ablations over many combinations and show that it works as well as or better than the considered combinations and signals*.\n\n2. Yes, the reviewer is correct to point this out. We had opted for this choice so that the same data is used across all the methods we test against for a fair comparison. Nevertheless, we agree with the reviewer that it is also important to have a standard calibration-test split to convincingly demonstrate that our method performs well on unseen data. We will ensure that we include new experiments to support this. We are happy to share additional results with the reviewer below, where for each model and target dataset, we compute the reference CDF by randomly sampling $100$ calibration data points from the other datasets. The table below shows the methods ranked by AUROC ($1=$best; ties get the mean rank) and averaged over 80 experiments (lower is better).\n\n | Method | Avg rank | Std rank | Median AUROC |\n |---|:---:|:---:|:---:|\n | KLE | 6.19 | 3.64 | 0.651 |\n | KLE (heat) | 6.19 | 3.64 | 0.651 |\n | CES x-ds 100 (unsup.) | 6.53 | 3.84 | 0.654 |\n | KLE (full) | 6.72 | 3.80 | 0.647 |\n | CES x-ds 100 (sup.) | 6.75 | 3.69 | 0.654 |\n | Embed. Regr. | 6.85 | 6.00 | 0.665 |\n | LN Entropy | 8.14 | 4.02 | 0.652 |\n | Perplexity | 8.14 | 4.02 | 0.652 |\n | Discrete SE | 8.61 | 4.18 | 0.634 |\n | LNE (bench) | 8.86 | 3.90 | 0.644 |\n | Effective Rank | 9.73 | 3.60 | 0.620 |\n | Eigenscore | 10.42 | 4.09 | 0.617 |\n | P(True) | 11.14 | 6.29 | 0.562 |\n | Semantic Entropy | 11.39 | 4.41 | 0.602 |\n | FAVA | 11.81 | 5.03 | 0.592 |\n | SelfCheckGPT | 11.97 | 3.87 | 0.602 |\n | Gen. Length | 13.49 | 4.36 | 0.562 |\n\n As we can see, the performance of CES (sup) is effectively unchanged compared to our previous results (Fig. 1 in the paper). In particular, we can conclude from these results that our method allows for using calibration data from unrelated sources (for a fixed model) and still retains its performance, showing high transferability across datasets. We thank the reviewer for asking us to run these experiments, and we believe that they significantly strengthen the results of our study. We will include these results to complement our existing ones and to convincingly demonstrate that our method performs just as well without the risk of information leakage.\n\n(Responses to the remaining follow-up questions are continued in the next comment.)"+ },+ "createdAt": "2026-08-03T18:28:25.773Z",+ "modifiedAt": "2026-11-19T16:41:54.842Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=fp8kJoNJoD",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/hxgqvrpftt.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/hxgqvrpftt.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "hxGQvrpftt",+ "replyTo": "PzMUzahpOr",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 1YLT",+ "content": {+ "title": "Response to rebuttal",+ "comment": "Thank you for the rebuttal. The experiments on calibration size significantly strengthens the computation cost argument of the paper since with just 2% of data the method shows strong results. Moreover, the experiment with non-overlapping calibration and eval sets addresses my concerns about generalization of the method. \n\nI will increase my score.\n\nA minor comment. I understand the assumption of conditional independence is mainly for clean maths. However, I do not quite follow the intuition provided by the authors here for weak dependency. What does \" Since information about \"which token\" will appear is irrecoverably lost once entropy is computed\" mean? The example is also a bit unclear since mean-centering random variables is a common trick employed to remove shared information (Z in this example) however what has this got to do with entropies being independent of the past while actual token log lkelihoods being dependent? Entropy is a function of log likelihoods, if the next token is highly certain given context, the entropy will be very low, similarly if the next token is start of a new sentence entropy will be much higher."+ },+ "createdAt": "2026-08-04T07:28:09.101Z",+ "modifiedAt": "2026-11-19T16:41:54.898Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=hxGQvrpftt",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/kudch2btev.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/kudch2btev.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "KuDcH2BTEV",+ "replyTo": "lhqWI6VlEl",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Meta Review",+ "comment": "We thank the AC and reviewers for their comments, and address the AC's highlighted concerns below, summarizing our replies to the reviewers.\n\n1. **Single-pass, high-performing method.** While calibration is needed, it is a one-time cost; afterwards each query needs exactly one generation—no extra samples, judge calls, NLI models, or trajectory comparisons. It is also cheap: (i) entropies cost a few milliseconds (even for size-$10^6$ vectors) and are computed during generation; (ii) building the reference CDF is easy since entropies are just real numbers; and (iii) only $\\sim2$% of calibration data matches full-data AUROC within $0.01$ (Q2, Reviewer 1YLT), so judge labels are needed on few samples once for CES (supervised), while CES (unsupervised) needs none. By contrast, KLE and other multi-sample methods pay their cost *per query* ($K\\geq5$ passes plus NLI calls). CES thus attains single-trajectory speed while sometimes outperforming multi-trajectory methods; cost experiments will be included.\n\n2. **Methodology and experiments.** We apologize for the unclear presentation and will expand explanations; the appendix answers many follow-up questions.\n\n - *fJ1W, Q3(2):* We agree CES (supervised) must be read carefully when calibration and evaluation share samples. Two points mitigate this: only $\\sim2$% of data is needed to calibrate (Q2(i), 1YLT), and our calibration-test split (Q2(ii), 1YLT) shows generalization to unseen data. Moreover, CES (unsupervised) uses no judge labels, so the concern does not apply.\n - *fJ1W, Q3(3):* Using the judge directly needs a per-query judge call, which CES avoids.\n - *fJ1W, Q3(4):* The unsupervised CDF pools all calibration entropies without labels (so no judge or tuning). $\\gamma$ is a theoretical contamination parameter, not tuned experimentally; robustness to contamination is shown in Appendix E.8.\n - *fJ1W, Q4:* AUROC needs no threshold; a deployed decision can fix a threshold on a validation set, at a target FPR, or via Youden's $J$. Theorem 2 guarantees TPR/FPR $\\to1/0$ exponentially in generation length for suitable values of two scalar parameters. We will fix the Table 1 typos.\n - *1YLT, Q1:* CES is used directly as a binary decision rule, not via a $p$-value. Thresholding is hard for all methods (hence AUROC), but Theorem 2 mitigates this for CES for suitable parameters.\n - *1YLT, Q5:* We addressed the specific points (Friedman/Nemenyi, pairwise comparisons, Fig. 2b) in our reply; details were cut for space, and the revision will interpret results more clearly.\n\n3. **Conditional independence.** We do not claim strict independence (see below Assumption 1); it is a simplifying assumption for clean theory, while empirically the method only needs stable separation between calibrated faithful and test summaries. We do expect only *weak* dependence: since information on \"which token\" appears next is lost once entropy is computed, dependence on context is correspondingly weakened. Appendix E.3 measures (rather than rules out) dependence, showing low *linear* dependence via autocorrelation; nonlinear dependence is harder to exclude, so we are happy to test specific forms and leave a fuller treatment to future work.\n\n4. **Max vs. length.** Following Reviewer rbqD, we isolated the max–length relation. The max term (and hence CES) is length-correlated, but the signal is not merely length: matched-length subsampling (hallucinated & faithful within a 2-token caliper, avg. $132.6$ pairs/run over 48 runs) gives CES AUROC $0.639\\pm0.078$ vs. length-only $0.502\\pm0.006$. Per-term ablation and length-stratified AUROC (in our reply to rbqD) likewise show the max term and CES clearly beat length-only. Generation length was already a baseline (Ref. [16]). We thank the reviewer for these suggestions.\n\n5. **KS test and scalar summary.** A two-sample KS test compares ECDFs of the faithful (calibration) and test (generation) distributions; since answers span only a few to a few dozen tokens, the generation ECDF is noisy and the test underperforms. CES mitigates this by keeping the calibrated reference distribution but summarizing the test data by two stable, cheap statistics: the mean entropy (a strong signal) and the max entropy (tail behavior). So CES is a scalar built from *calibrated* distributional summaries rather than a raw mean or max, unlike prior single-scalar detectors.\n\n6. **CES (sup) vs. (unsup).** The two are essentially tied: on a held-out split, CES (sup) AUROC is $0.632\\pm0.082$ and CES (unsup) AUROC $0.633\\pm0.082$. Where unsupervised is marginally better, this likely reflects its larger calibration pool and better upper-tail coverage, whereas the supervised reference (judged-faithful only) is smaller and can saturate for high-entropy generations. The point is not that supervision fails but that unsupervised calibration matches it at no judge-label cost.\n\nWe again thank the AC and reviewers, and we welcome any further questions during the discussion period."+ },+ "createdAt": "2026-07-29T02:48:30.658Z",+ "modifiedAt": "2026-11-19T16:41:54.918Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=KuDcH2BTEV",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/lhqwi6vlel.json modified
+++ b/reviews/openreview/yexkhj9iy3/notes/lhqwi6vlel.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair QJM9","content": {- "metareview": "This authors present a new method for detecting hallucination in language models. Their method computes entropy for each token distribution produced by the model. It then uses the distribution of entropies to discriminate between hallucinated and non-hallucinated responses. They argue that the shape of the distribution is critical to achieve this separation and that using a simple statistic, such as the mean of these entropies, is insufficient. They distinguish their work from previous attempts at hallucination detection by emphasizing its practicality: requiring a single inference step and access to model logits (but not internals). They provide theoretical results and empirical results on ten instruction-tuned models and eight QA benchmarks. \n\nReviewers agree that this paper is well-motivated and sets out to solve an important problem with a new idea. The experiments appear to be quite expansive. \n\nHowever, reviewers also point out several weaknesses and limitations that may result in this paper being rejected. The authors should focus on addressing all of the reviewers’ comments. If prioritization is needed, I would recommend the following order:\n\nMost Serious: \nReviewer 1YLT (Weakness 3) points out that the single-pass nature of the method may be over-stated, as it leaves out the calibration required for this method. I would be interested to hear the authors’ response to this comment. In particular, the empirical results demonstrate that the CES is quite good only among single-pass methods. If CES is indeed more comparable to KLE in its ease-of-deployment, then this substantially alters how we should interpret the empirical results. \n\nReviewers identify several specific methodological and presentational issues with the experiments. I would be interested in the authors’ rebuttal to all of these, but specifically: Question 3, subparts (2)-(4) and Question 4. Similarly, Reviewer 1YLT raises presentational issues in Weaknesses 1 and 5. \n\nImportant: \nMultiple reviewers are skeptical of Theorem 1’s assumption that token entropies are iid conditioned on length. I would be interested in hearing how the authors reason about this assumption. \n\nReviewer rbqD points out that maximum entropy may be serving as a proxy for length, and suggests some very good suggestions for isolating this effect. Authors need not implement all suggestions, but some signal around this question would be helpful. \n\nReviewer rbqD and fJ1W point out that ultimately as KS-style test is not used, and the method ultimately collapses the information in the token distributions to a single scalar. Does this alter the paper’s framing that this method is effective because it considers the entire shape of the entropy distribution? \n\nI think Reviewer fj1W means to say “CES (unsup) performs better than CES (sup) in all settings” in Question 3, subpart (1). This is indeed unexpected, and deserves explanation."+ "metareview": "This authors present a new method for detecting hallucination in language models. Their method computes entropy for each token distribution produced by the model. It then uses the distribution of entropies to discriminate between hallucinated and non-hallucinated responses. They argue that the shape of the distribution is critical to achieve this separation and that using a simple statistic, such as the mean of these entropies, is insufficient. They distinguish their work from previous attempts at hallucination detection by emphasizing its practicality: requiring a single inference step and access to model logits (but not internals). They provide theoretical results and empirical results on ten instruction-tuned models and eight QA benchmarks. \n\nReviewers agree that this paper is well-motivated and sets out to solve an important problem with a new idea. The experiments appear to be quite expansive. \n\nHowever, reviewers also point out several weaknesses and limitations that may result in this paper being rejected. The authors should focus on addressing all of the reviewers’ comments. If prioritization is needed, I would recommend the following order:\n\nMost Serious: \nReviewer 1YLT (Weakness 3) points out that the single-pass nature of the method may be over-stated, as it leaves out the calibration required for this method. I would be interested to hear the authors’ response to this comment. In particular, the empirical results demonstrate that the CES is quite good only among single-pass methods. If CES is indeed more comparable to KLE in its ease-of-deployment, then this substantially alters how we should interpret the empirical results. \n\nReviewers identify several specific methodological and presentational issues with the experiments. I would be interested in the authors’ rebuttal to all of these, but specifically: Question 3, subparts (2)-(4) and Question 4. Similarly, Reviewer 1YLT raises presentational issues in Weaknesses 1 and 5. \n\nImportant: \nMultiple reviewers are skeptical of Theorem 1’s assumption that token entropies are iid conditioned on length. I would be interested in hearing how the authors reason about this assumption. \n\nReviewer rbqD points out that maximum entropy may be serving as a proxy for length, and suggests some very good suggestions for isolating this effect. Authors need not implement all suggestions, but some signal around this question would be helpful. \n\nReviewer rbqD and fJ1W point out that ultimately as KS-style test is not used, and the method ultimately collapses the information in the token distributions to a single scalar. Does this alter the paper’s framing that this method is effective because it considers the entire shape of the entropy distribution? \n\nI think Reviewer fj1W means to say “CES (unsup) performs better than CES (sup) in all settings” in Question 3, subpart (1). This is indeed unexpected, and deserves explanation.",+ "final_justification": "Having read the extensive discussion between the reviewers and authors, I believe this paper should be accepted. The most controversial point — data leakage in the experiments — is addressed by the authors in a number of ways. \n1. One of the main take-aways of the paper is that CES(unsup) and CES(sup) are essentially tied, where CES(unsup) does not require judge-labels. The authors’ claim that the calibration concerns do not apply to CES(unsup) goes a long way to mollifying this concern.\n2. The provided CES x-ds experiments are compelling and establish that calibration can be attained from unrelated sources. \n3. Structurally, the calibration estimates a 1-D CDF, using a very small fraction of the data, making overfitting to individual test points unlikely.\n4. The half-split experiment drops AUROC from 0.653 to 0.632, which superficially is ~0.02, and within the margins enjoyed by CES over single-pass baselines. Nevertheless, this is relatively uninformative as the significance of this drop is unclear without a paired rank analysis. In light of 1-3, I do not view this as a reason enough to reject the paper. I also generally agree with the more positive reviewers that even in the absence of a SOTA claim, the paper provides a solid framework and insights. \nOverall, I believe that this method is convincing as a practical, cheap, alternative for hallucination-detection that competes with heavier-weight multi-trajectory methods."},"createdAt": "2026-07-22T16:30:24.638Z",- "modifiedAt": "2026-11-18T15:24:42.972Z",+ "modifiedAt": "2026-11-19T05:02:59.477Z","url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=lhqWI6VlEl","license": "CC-BY-4.0"}
reviews/openreview/yexkhj9iy3/notes/orxus81pj5.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/orxus81pj5.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "orxUs81pj5",+ "replyTo": "d3iwch0kql",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer's Comments (Part II)",+ "comment": "7. **Threshold selection and table formatting.** For AUROC evaluation no threshold is selected, as AUROC measures ranking quality across all thresholds. For a binary decision for deployment, a threshold can be chosen on a held-out validation set, by fixing a desired false-positive rate under the calibration reference, or by maximizing Youden's $J$ when labels are available. On the table formatting, we thank the reviewer for catching this and will correct the bold/underline conventions in Table 1 in the revision and apologize for the typos."+ },+ "createdAt": "2026-07-28T21:12:22.994Z",+ "modifiedAt": "2026-11-19T16:41:54.911Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=orxUs81pj5",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/pzmuzahpor.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/pzmuzahpor.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "PzMUzahpOr",+ "replyTo": "3FSAQkACpm",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional Results",+ "comment": "**Calibration Size.** We present additional evidence below, supporting our answer to Q2(i), showing that the $\\sim 2$% calibration data result holds individually for the datasets we tested.\n\nIn this experiment, for each (model, dataset) pair, the CES reference distribution $F_0$ is rebuilt from a random fraction of the calibration pool (faithful-only for the supervised setting, all generations for the unsupervised setting), the CES is recomputed and AUROC measured, and averaged over $8$ random draws. We denote $f^{\\star}$ to be the smallest fraction whose AUROC reaches within 0.01 of the full-data (100%) AUROC (smaller = converges with less calibration data). $n_{\\mathrm{faith}}$ is the total number of non-hallucinated (faithful) samples available for calibration in each dataset. All entries are mean $\\pm$ std across models.\n\n| Dataset | $n_{\\mathrm{faith}}$ | $\\text{AUROC}_{\\mathrm{sup}}$ | $\\text{AUROC}_{\\mathrm{unsup}}$ | $f^{\\star}_{\\mathrm{sup}}$ (%) | $f^{\\star}_{\\mathrm{unsup}}$ (%) |\n|---|:---:|:---:|:---:|:---:|:---:|\n| bioasq | 3524 | $0.636 \\pm 0.058$ | $0.636 \\pm 0.058$ | $2 \\pm 0$ | $2 \\pm 0$ |\n| coqa | 4436 | $0.653 \\pm 0.042$ | $0.654 \\pm 0.043$ | $2 \\pm 0$ | $2 \\pm 0$ |\n| drop | 2772 | $0.642 \\pm 0.034$ | $0.643 \\pm 0.033$ | $2 \\pm 0$ | $2 \\pm 0$ |\n| gsm8k | 4078 | $0.629 \\pm 0.090$ | $0.629 \\pm 0.090$ | $2 \\pm 0$ | $2 \\pm 0$ |\n| nq_open | 2248 | $0.601 \\pm 0.078$ | $0.601 \\pm 0.078$ | $2 \\pm 0$ | $2 \\pm 0$ |\n| squad | 3459 | $0.668 \\pm 0.063$ | $0.668 \\pm 0.063$ | $2 \\pm 0$ | $2 \\pm 0$ |\n| svamp | 1907 | $0.702 \\pm 0.066$ | $0.704 \\pm 0.067$ | $3 \\pm 1$ | $2 \\pm 1$ |\n| triviaqa | 4467 | $0.693 \\pm 0.061$ | $0.693 \\pm 0.061$ | $2 \\pm 0$ | $2 \\pm 0$ |\n| **All** | 26891 | $0.653 \\pm 0.069$ | $0.654 \\pm 0.069$ | $2 \\pm 1$ | $2 \\pm 0$ |"+ },+ "createdAt": "2026-07-30T21:23:43.730Z",+ "modifiedAt": "2026-11-19T16:41:54.911Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=PzMUzahpOr",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/qa4o8sjcvu.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/qa4o8sjcvu.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "qa4O8SJcVu",+ "replyTo": "chUdChKS2h",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer's Comments (Part II)",+ "comment": "6. **Correlation of length with signal.** We compute the Spearman correlations (mean $\\pm$ std and pooled across (model, dataset) pairs) between length, CES and max components, and also LNE.\n\n Table 3:\n\n | Relationship | Spearman $\\rho$ (mean $\\pm$ std) | Pooled $\\rho$ |\n |---|:---:|:---:|\n | Length vs CES | $+0.218 \\pm 0.313$ | $+0.388$ |\n | Length vs $F_0(\\max h)$ | $+0.430 \\pm 0.204$ | $+0.611$ |\n | $F_0(\\max h)$ vs LNE | $+0.766 \\pm 0.149$ | $+0.172$ |\n\n Length is reasonably correlated with CES, driven by the max term (expected, since $F_0(\\max h)$ rises with length). While such a correlation exists, our answers to the following questions should clarify that CES (and the max term) provides more signal over just length alone. Interestingly, the calibrated max term is also strongly correlated with LNE, which we will investigate further. We will also follow reviewer's suggestion to soften the ``distributional framing\".\n\n*Responses to questions.*\n\n1. **Per-term ablation.** For the average term $F_0(\\bar h)$, the max term $F_0(h_{\\max})$, the combined $\\mathrm{CES}=\\sqrt{F_0(\\bar h)\\,F_0(h_{\\max})}$, and generation length, we report AUROC, Spearman correlation with the hallucination label, that correlation after partialling out length ($\\rho(\\cdot,\\mathrm{hall}\\mid L)$), and coupling to length $\\rho(\\cdot,L)$ (mean $\\pm$ std across paper's 48 open-weight model-dataset runs):\n\n Table 4:\n\n | Score component | AUROC | $\\rho(\\cdot,\\mathrm{hall})$ | $\\rho(\\cdot,\\mathrm{hall}\\mid L)$ | $\\rho(\\cdot,L)$ |\n |---|:---:|:---:|:---:|:---:|\n | Average term $F_0(\\bar h)$ | $0.627 \\pm 0.071$ | $0.183 \\pm 0.111$ | $0.198 \\pm 0.111$ | $-0.169 \\pm 0.210$ |\n | Maximum term $F_0(h_{\\max})$ | $0.634 \\pm 0.070$ | $0.192 \\pm 0.106$ | $0.183 \\pm 0.107$ | $0.347 \\pm 0.169$ |\n | Combined CES | $0.636 \\pm 0.074$ | $0.196 \\pm 0.115$ | $0.197 \\pm 0.111$ | $0.028 \\pm 0.226$ |\n | Generation length | $0.545 \\pm 0.041$ | $0.064 \\pm 0.058$ | — | $1.000 \\pm 0.000$ |\n\n The combined score beats either component alone, and both beat generation length by a wide margin. Crucially, the association with hallucination is essentially unchanged after partialling out length ($\\rho(\\cdot,\\mathrm{hall}\\mid L)\\approx\\rho(\\cdot,\\mathrm{hall})$): the max term is length-coupled but is still a much better hallucination detector than length. The length alone does not explain CES.\n\n2. **Length-only baseline.** Generation length is already a baseline (\"Gen. Length\"); we apologize if this was unclear. The correlations above show the max–length coupling is only partly retained in CES.\n We have also checked the relationship between CES's average-entropy term and length-normalized predictive entropy, and as expected the Spearman correlation is exactly 1. This is because $F_0$ is monotone and hence, $F_0(h)$ is rank preserving recalibration of the mean token entropy, yielding identical AUROC.\n\n3. **Behaviour of the max term with length.** On faithful data, the max term rises with length. Over $14{,}966$ faithful generations, Spearman is $0.432$ for length vs. raw max entropy and $0.630$ for length vs. calibrated max. Across length quartiles (lengths $1$–$3$, $3$–$5$, $5$–$12$, $12$–$256$) the mean raw max goes $2.20\\to2.13\\to2.48\\to3.52$ and the calibrated max rises more clearly, from $0.731$ to $0.965$. The reference CDF is computed from samples pooled over all lengths, the case Theorem 1 covers directly.\n\n4. **Length-decorrelated evaluation.** As per reviewer's suggestion, we implemented matched-length subsampling, by matching hallucinated and faithful generations within a 2-token caliper (avg. $132.6$ matched pairs per run across the 48 runs). This gives CES AUROC $0.639\\pm0.078$ vs. length-only AUROC $0.502\\pm0.006$, with a mean hallucinated-minus-faithful length gap of only $0.019\\pm0.054$ tokens. This is the cleanest evidence that the signal is not merely length.\n\n5. **Relationship to length-aware baselines.** As shown in Q2, the average term and LN predictive entropy have Spearman correlation exactly $1$. The paper already includes comprehensive comparisons with LNE, Semantic Entropy (SE), and Discrete SE. We apologize if this was unclear in the paper and we will highlight these more clearly."+ },+ "createdAt": "2026-07-28T21:09:12.173Z",+ "modifiedAt": "2026-11-19T16:41:55.071Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=qa4O8SJcVu",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/qdnsxijzay.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/qdnsxijzay.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "QDNSXIJZAy",+ "replyTo": "eFCrYkptRt",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response To Reviewer's Comments (Part I)",+ "comment": "We thank the reviewer for going through our paper in detail and for recommending clarifications that will convey our results better. Due to space constraints, many experimental details were moved to the appendices; important ones will be moved back and the presentation and discussion improved in the revision. We address each point below.\n\n1. **Methodology and parameter choice.** We apologize that the reviewer found the methodology and the experiments in the paper unclear. We will clarify the choice of parameters and provide a more detailed discussion and explanation of the experiments. A hypothesis test for the null can report a $p$-value (e.g., the KS test, which can be turned into a binary decision) or reject the null directly. We take the second approach: CES is a test statistic that rejects the null based on two tunable parameters. We agree that choosing a good threshold is a challenge for all methods, which is exactly what motivates comparing methods via AUROC. To alleviate this, Theorem 2 provides guarantees on the true and false positive rates (TPR, FPR) *directly in terms of the tunable parameters*, showing the FPR falls exponentially with generation length, while the TPR approaches $1$ exponentially fast, over a range of parameter choices. This lends credence to reporting AUROC, since it shows the two parameters can be tuned (e.g., on a validation set) to achieve good rejection. It also directly addresses the reviewer's comment to detect hallucinations with a stated confidence: rather than a $p$-value, one can choose the parameters to control a target FPR (equivalently, a significance level) under the calibration reference, with the guarantee that the TPR then still approaches $1$ with generation length. We will clarify parameter selection in the revised manuscript.\n\n2. **Same data for calibration and evaluation.** We acknowledge that the scenarios faced by LLMs are of unprecedented complexity and expect performance to vary across them; what we assess is a general comparison against popular hallucination detectors, showing better predictive power than most comparable methods. We have not seen hallucination assessed in the specific scenarios raised, and would welcome suggestions for further testing, but relative to recent literature we provide exhaustive evidence across a large variety of scenarios and models, following the setup of Nikitin et al. (Ref. [31] in paper). To address the amount of calibration data and generalizability directly, we add two experiments.\n\n (i) *Calibration size* (Table 1). For each (model, dataset) pair, the reference $F_0$ is rebuilt from a random fraction of the calibration pool (faithful-only for supervised, all generations for unsupervised), CES is recomputed and AUROC measured, averaged over 8 random draws. Let $f^{\\star}$ be the smallest fraction whose AUROC reaches within $0.01$ of the full-data value (smaller = converges with less data); $n_{\\mathrm{faith}}$ is the number of faithful calibration samples. Entries are mean $\\pm$ std across models; we have $26891$ faithful samples in total and will report disaggregated values in the revision. The median convergence fraction is $2$% for both the supervised setting (median full AUROC $0.653$) and the unsupervised setting (median full AUROC $0.653$). Thus a very small fraction of calibration data suffices in practice—as expected from Theorem 1, where the reference-CDF estimation error decays exponentially in the number of samples.\n\n Table 1:\n\n | Dataset | $n_{\\mathrm{faith}}$ | $\\text{AUROC}_{\\mathrm{sup}}$ | $\\text{AUROC}_{\\mathrm{unsup}}$ | $f^{\\star}_{\\mathrm{sup}}$ (%) | $f^{\\star}_{\\mathrm{unsup}}$ (%) |\n |---|:---:|:---:|:---:|:---:|:---:|\n | **All** | 26891 | $0.653 \\pm 0.069$ | $0.654 \\pm 0.069$ | $2 \\pm 1$ | $2 \\pm 0$ |\n\n (ii) *Calibration-test split.* We also perform a separate experiment where calibration and evaluation samples are separated by random half-splits over 8 draws per run on paper's open-weight model-dataset pairs. We find that the supervised CES remains $0.632 \\pm 0.082$ and unsupervised CES remains $0.633 \\pm 0.082$ compared to using full data. This directly shows that our method generalizes to unseen data.\n\n(Answers to Q3-Q5 continued in the next comment due to 5000 character limit)"+ },+ "createdAt": "2026-07-28T21:03:58.238Z",+ "modifiedAt": "2026-11-19T16:41:55.401Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=QDNSXIJZAy",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/tmcru6ebjn.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/tmcru6ebjn.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "TMcRU6EBJN",+ "replyTo": "hxGQvrpftt",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the positive assessment, we are glad and agree that the results that were prompted by the review process provide a stronger exposition! Thank you for your help. \n\nThe point is about the scalar entropy: the token distribution carries essentially all of the context-dependent information since it determines which token is likely next. This is coupled across positions because context accumulates and each emitted token feeds forward. The entropy, by contrast, is a lossy, many-to-one functional of that distribution: it retains only how peaked vs. spread the distribution is, not the _which_ tokens are being propagated forward. Simply put, two positions with very different contexts and predicted tokens can have nearly identical entropy. The mechanism that most strongly propagates dependence through the sequence, i.e. _which_ specific tokens were emitted, acts on $H_t$ indirectly. In this sense, we expect the token entropies to be _weakly_ dependent. We apologize if the example was not a helpful clarification; we leave a formal treatment of dependence (including nonlinear forms) to future work."+ },+ "createdAt": "2026-08-04T09:48:02.627Z",+ "modifiedAt": "2026-11-19T16:41:54.914Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=TMcRU6EBJN",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/voa8twqavc.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/voa8twqavc.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "voa8TWqaVC",+ "replyTo": "088txEy7RX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to follow-up questions",+ "comment": "We thank the reviewer for going through our responses in detail, and we are happy that the reviewer finds our additional results convincing. We will include all these additional results in the revised manuscript, as we believe they will significantly strengthen our study.\n\nRegarding the question on paired per-run comparisons that the reviewer inquired about, we would like to point the reviewer to Fig. 9 of our Appendix E.7, where we perform a detailed ablation study which shows that combined CES consistently outranks the max term alone (note that the max term does not appear in the figure because it does not rank in the top 10).\n\nYes, as per the reviewer's suggestion, we will include the stationarity results, comment on the entropy drop across the initial tokens, and explain how it relates to our independence assumption."+ },+ "createdAt": "2026-08-03T18:33:07.032Z",+ "modifiedAt": "2026-11-19T16:41:54.826Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=voa8TWqaVC",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/vrky8n7bkf.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/vrky8n7bkf.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "vrky8N7bkf",+ "replyTo": "KuDcH2BTEV",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Thanks",+ "comment": "We thank all reviewers collectively for engaging with the paper and providing thoughtful and truly detailed feedback that has no doubt improved the presentation and thoroughness of our exposition; we are grateful for the attention and participation. We look forward to the decision and wish all reviewers a stimulating discussion."+ },+ "createdAt": "2026-08-04T09:49:30.240Z",+ "modifiedAt": "2026-11-19T16:41:54.807Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=vrky8N7bkf",+ "license": "CC-BY-4.0"+}
reviews/openreview/yexkhj9iy3/notes/xbl1y6ehsa.json added
+++ b/reviews/openreview/yexkhj9iy3/notes/xbl1y6ehsa.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "xbl1Y6EHsA",+ "replyTo": "csocTjOQ8Z",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer fJ1W",+ "content": {+ "comment": "Thank the authors for the responses. I will discuss these with other reviewers."+ },+ "createdAt": "2026-08-03T22:25:16.219Z",+ "modifiedAt": "2026-11-19T16:41:54.801Z",+ "url": "https://openreview.net/forum?id=yeXKhJ9iy3¬eId=xbl1Y6EHsA",+ "license": "CC-BY-4.0"+}