potentialpaper

Scaling Generative Foundation Models for Chest Radiography with Rectified Flow Transformers

Update NeurIPS 2026 submission GDtwvgMFLg: 6 notes

@openreview[bot] · 2026-11-24 15:48 UTC · 463457e61024 ·

Evidence

reviews/openreview/gdtwvgmflg/notes/36orbgco33.json added

+++ b/reviews/openreview/gdtwvgmflg/notes/36orbgco33.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "36Orbgco33",
+ "replyTo": "8KEAW4WZDI",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response: Part 2/2",
+ "comment": "**(Continued from above.)**\n\n**7.** As suggested, we ran additional experiments inspired by the **downstream image segmentation task** from Dutt et al (2025). Specifically, we generated pseudo ground-truth masks for 14 different structures using the PSPNet segmentation model from torchxrayvision. To assess the benefits of synthetic data, we supplemented 50k real image-mask pairs with 50k synthetic pairs from our RadiT XL model. We then trained two segmentation models, one on real and one on real + synthetic data. We used the UNet (ResNet34) from: github.com/qubvel-org/segmentation_models.pytorch. Both models were trained on 1.92M images with 512x512 resolution and identical experimental setups. The best checkpoint was selected according to validation Dice score.\n\n| Structure | Real Dice | Real + Synthetic Dice | Relative Improvement |\n|---|---:|---:|---:|\n| Left Clavicle | 0.7457 | 0.7955 | +6.68% |\n| Right Clavicle | 0.7613 | 0.7988 | +4.93% |\n| Left Scapula | 0.7346 | 0.7557 | +2.87% |\n| Right Scapula | 0.7526 | 0.7755 | +3.04% |\n| Left Lung | 0.8509 | 0.8614 | +1.23% |\n| Right Lung | 0.8552 | 0.8635 | +0.97% |\n| Left Hilus Pulmonis | 0.6549 | 0.6870 | +4.90% |\n| Right Hilus Pulmonis | 0.7147 | 0.7376 | +3.20% |\n| Heart | 0.7713 | 0.7904 | +2.48% |\n| Aorta | 0.6911 | 0.7164 | +3.66% |\n| Facies Diaphragmatica | 0.8449 | 0.8577 | +1.51% |\n| Mediastinum | 0.7840 | 0.8022 | +2.32% |\n| Weasand | 0.7618 | 0.7904 | +3.75% |\n| Spine | 0.8058 | 0.8239 | +2.25% |\n| **Average** | **0.7663** | **0.7897** | **+3.05%** |"
+ },
+ "createdAt": "2026-08-02T15:47:32.076Z",
+ "modifiedAt": "2026-11-19T17:10:13.839Z",
+ "url": "https://openreview.net/forum?id=GDtwvgMFLg&noteId=36Orbgco33",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/gdtwvgmflg/notes/3zupgnpczs.json added

+++ b/reviews/openreview/gdtwvgmflg/notes/3zupgnpczs.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "3zuPgNpCZS",
+ "replyTo": "8KEAW4WZDI",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer gZvw",
+ "content": {
+ "title": "Rebuttal acknowledgement",
+ "comment": "Dear authors,\nThank you for providing a very detailed rebuttal and conducting additional experiments to the comments raised during the review. Based on the rebuttal, I'm willing to raise my score to a borderline accept with many remaining concerns:\n\n1. The clinical utility study of using synthetic samples alone shows the performance to match the real dataset. However, the task is targeted at Chexpert-14 which was a subset of the collected CRX-1M dataset. The correct experiment here would be to use random 50k samples from the proposed dataset vs the generated synthetic dataset. Also, if the model scores on par to the real dataset, how does that confirm usefulness? What if the generated model had over-fitted on the real data distribution which would also create a synthetic data similar to the real dataset and scores matching the same.\n\n2. For the bias mitigation experiment, I notice the same. The downstream model is trained on a biased but a smaller distribution (MIMIC) of the dataset on which RadiT was trained. Here using the same training distribution is needed for a fair comparison.\n\n3. Could the authors explain why the scores of male category reduced after the addition of the synthetic samples ?\n\n4. I have to respectfully disagree with the claim that \"systematic evaluation of model design choices, image editing capabilities, and identity preservation\" provides a methodological contribution. In my view, this is very important for field to understand what the nuances of using different models with different capacity means for a practical usage and not directly as a methodological contribution. Given that, I would consider this work to be a contribution of dataset and deeper analysis and insights of using large scale dataset for generating synthetic samples (which is indeed needed and useful for the community). IMO, not every contribution needs to be a methodological one.\n\n5. To quote the exps. with SANA model and the image quality metrics. As mentioned by other reviewers showing higher image quality metrics does not mean true clinical utility. The expected exps. here would be to use them in downstream tasks to show they do much better performance than RadiT (trained on only MIMIC).\n\n6. I find the agreement on the 512x512 resolution confounding. As shown clearly in Table.1 of (Dutt et al., 2026), the resolution of the baseline SD V-3.5M and LLM-CXR to be 1024 and 256 respectively. The authors have clearly used the same values from the table for this paper but claim to have used a resolution of 512. So, resizing the images did not cause any change in these metric values even to a decimal scale. This really raises an integrity of the answer.\n\n7. I agree with the authors claims of a foundational model being trained \"on broad data and adaptable to a wide range of downstream tasks\". However, the paper and the rebuttal shows one downstream task of classification (bias mitigation is again classification). As pointed out in the review, having a closer look at Dutt et al's work shows how else the synthetic data should/could be evaluated."
+ },
+ "createdAt": "2026-08-02T06:58:51.409Z",
+ "modifiedAt": "2026-11-19T17:10:13.685Z",
+ "url": "https://openreview.net/forum?id=GDtwvgMFLg&noteId=3zuPgNpCZS",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/gdtwvgmflg/notes/ccojkxtc0d.json modified

+++ b/reviews/openreview/gdtwvgmflg/notes/ccojkxtc0d.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair R3at",
"content": {
- "metareview": "Final Meta Review\n---------------------\n\nThe work presented in this paper constitutes a strong and well-executed contribution to generative medical imaging and merits acceptance. The work stands out through several complementary contributions spanning resources, engineering, and empirical validation.\n\n• Main Contributions\n\nA benchmark dataset for the community. The curation of CXR7-1M—1.2 million harmonized chest X-rays assembled from seven public sources, with clinician-in-the-loop mapping—addresses a genuine need in the field and, independently of the proposed model, represents a lasting resource for future research.\n\nA credible and well-substantiated scaling effort. RadiT XL is the first specialist CXR model trained from scratch at the billion-parameter scale, rather than fine-tuned from a natural-image model. The ablation studies are informative (specialized vs. generic VAE, architecture, and scaling), and, most importantly, the authors have rigorously addressed the request for experimental controls: the cross-training experiments (RadiT on the MIMIC split used by the baselines, and Sana on CXR7-1M) demonstrate that the fidelity gains are not simply an artifact of the larger training set, but genuinely reflect the contribution of the modeling recipe itself.\n\nA now-substantiated demonstration of clinical utility. The addition, in response to the reviewers, of experiments on data augmentation, subgroup debiasing, and counterfactual classifier stress testing transforms a theoretical promise (stated in the introduction) into a concrete empirical demonstration. These are precisely the use cases that justify the model’s relevance beyond visual fidelity alone.\n\nA strengthened and transparent expert study. Extending the blinded study to include the baselines (detectability rates of 0.79–0.82 for the competing methods versus 0.54, close to chance level, for RadiT), together with subgroup stratification, provides a level of granularity that is rare in this type of evaluation. The authors also report sample-size limitations openly rather than obscuring them.\n\nAn exemplary response to the review process. Beyond the scientific content itself, the quality of the response—three new sets of controlled experiments, quantitative tables, and explicit acknowledgment of unresolved limitations—demonstrates a level of scientific rigor that further increases confidence in the overall work.\n\n• Suggested Improvements (Non-Blocking)\n\nThese points do not undermine the recommendation for acceptance, but addressing them in the final version or in future work would further strengthen the paper:\n\n* Clinically validate the correctness of counterfactual edits beyond image-similarity metrics such as SSIM/LPIPS, ideally through expert assessment of a subset of edited images, in order to fully substantiate the model’s central causal claim.\n* Provide a quantitative ablation of robustness to label noise, even if limited in scope, rather than relying solely on a qualitative response. This would be particularly useful for future users of the dataset.\n* Refine the wording around “isolating the architecture” in the final manuscript by clarifying that the controlled comparison isolates the overall training recipe (VAE, causal conditioning, and hyperparameters), rather than the architecture alone.\n* Add confidence intervals to the data-augmentation gains, whose magnitude varies substantially across pathologies (from less than 1% to approximately 9%), to avoid an overly uniform interpretation of the results.\n* Clarify the terminology “foundation model” by explicitly defining the precise scope of the term in the introduction (metadata-to-image rather than multimodal report-to-image), thereby avoiding potential confusion for readers."
+ "metareview": "Final Meta Review\n---------------------\n\nThe work presented in this paper constitutes a strong and well-executed contribution to generative medical imaging and merits acceptance. The work stands out through several complementary contributions spanning resources, engineering, and empirical validation.\n\n• Main Contributions\n\nA benchmark dataset for the community. The curation of CXR7-1M—1.2 million harmonized chest X-rays assembled from seven public sources, with clinician-in-the-loop mapping—addresses a genuine need in the field and, independently of the proposed model, represents a lasting resource for future research.\n\nA credible and well-substantiated scaling effort. RadiT XL is the first specialist CXR model trained from scratch at the billion-parameter scale, rather than fine-tuned from a natural-image model. The ablation studies are informative (specialized vs. generic VAE, architecture, and scaling), and, most importantly, the authors have rigorously addressed the request for experimental controls: the cross-training experiments (RadiT on the MIMIC split used by the baselines, and Sana on CXR7-1M) demonstrate that the fidelity gains are not simply an artifact of the larger training set, but genuinely reflect the contribution of the modeling recipe itself.\n\nA now-substantiated demonstration of clinical utility. The addition, in response to the reviewers, of experiments on data augmentation, subgroup debiasing, and counterfactual classifier stress testing transforms a theoretical promise (stated in the introduction) into a concrete empirical demonstration. These are precisely the use cases that justify the model’s relevance beyond visual fidelity alone.\n\nA strengthened and transparent expert study. Extending the blinded study to include the baselines (detectability rates of 0.79–0.82 for the competing methods versus 0.54, close to chance level, for RadiT), together with subgroup stratification, provides a level of granularity that is rare in this type of evaluation. The authors also report sample-size limitations openly rather than obscuring them.\n\nAn exemplary response to the review process. Beyond the scientific content itself, the quality of the response—three new sets of controlled experiments, quantitative tables, and explicit acknowledgment of unresolved limitations—demonstrates a level of scientific rigor that further increases confidence in the overall work.\n\n• Suggested Improvements (Non-Blocking)\n\nThese points do not undermine the recommendation for acceptance, but addressing them in the final version or in future work would further strengthen the paper:\n\n* Clinically validate the correctness of counterfactual edits beyond image-similarity metrics such as SSIM/LPIPS, ideally through expert assessment of a subset of edited images, in order to fully substantiate the model’s central causal claim.\n* Provide a quantitative ablation of robustness to label noise, even if limited in scope, rather than relying solely on a qualitative response. This would be particularly useful for future users of the dataset.\n* Refine the wording around “isolating the architecture” in the final manuscript by clarifying that the controlled comparison isolates the overall training recipe (VAE, causal conditioning, and hyperparameters), rather than the architecture alone.\n* Add confidence intervals to the data-augmentation gains, whose magnitude varies substantially across pathologies (from less than 1% to approximately 9%), to avoid an overly uniform interpretation of the results.\n* Clarify the terminology “foundation model” by explicitly defining the precise scope of the term in the introduction (metadata-to-image rather than multimodal report-to-image), thereby avoiding potential confusion for readers.",
+ "final_justification": "Overall, the paper represents a substantial and convincing contribution, supported by a strong combination of methodological development, dataset curation, controlled experimentation, and clinically relevant validation. The authors’ thorough response to the review process further strengthens the case for acceptance."
},
"createdAt": "2026-07-23T20:47:54.782Z",
- "modifiedAt": "2026-11-18T15:24:53.395Z",
+ "modifiedAt": "2026-11-19T05:03:06.029Z",
"url": "https://openreview.net/forum?id=GDtwvgMFLg&noteId=cCOjkxTc0d",
"license": "CC-BY-4.0"
}

reviews/openreview/gdtwvgmflg/notes/exyiu0yfps.json added

+++ b/reviews/openreview/gdtwvgmflg/notes/exyiu0yfps.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "eXyIU0yFpS",
+ "replyTo": "3zuPgNpCZS",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response: Part 1/2",
+ "comment": "Dear Reviewer, thank you for reconsidering our work and for raising your score. We appreciate your feedback and address each remaining point below.\n\n**1.** To clarify, we did in fact use 50k random samples from the full real dataset (CXR7-1M) and 50k random samples that were generated with RadiT, exactly as suggested by the reviewer. We trained a classifier to *predict* the CheXpert-14 pathology *labels*, which is the label convention used in our CXR7-1M dataset. We believe the reviewer confused the CheXpert-14 labels with the CheXpert dataset (which is a subset of CXR7-1M). Importantly, these 50k synthetic samples were generated with a metadata distribution that RadiT had not seen during training. We believe that the on-par performance demonstrates usefulness since it shows that RadiT is able to faithfully model the real data distribution.\n\n**2.** In our bias mitigation experiment (as with all of our downstream testing experiments), we were careful not to use data on which RadiT was trained. Here, we again trained an external classifier on a subset of real data (with known bias), and performed subgroup balancing using RadiT *test set* samples. These results show that using our synthetic data to perform subgroup balancing on real datasets is able to mitigate subgroup disparities. To clarify, in the Race experiment, we used only real MIMIC data to train the classifier and RadiT samples conditioned on the MIMIC dataset to upsample the minority group, since this data is widely used in the bias analysis literature (Gichoya et al. 2022, Seyyed-Kalantari et al. 2021). We did not specify dataset conditioning in the Sex experiment, since all datasets in CXR7-1M contain this information. We highlight that studying dataset bias and its effect on model bias is non-trivial due to mixing effects of different sources of bias in real datasets. To evaluate the effect of debiasing, it is therefore important to control for the initial dataset bias, which is why we opted for a setup with controlled subgroup disparities (similar to Larrazabal et al. 2020).\n\n**3.** Debiasing models can often have negative effects for the initially better-performing group, known as “leveling down” [1]. Whether this phenomenon occurs is dependent on how a model exploited dataset biases in the “naive” scenario. For example, with a higher prevalence of males, the model could have been using male-specific features as shortcuts to artificially boost overall performance. After subgroup balancing, these features would no longer be a shortcut for improving performance, forcing the model to rely on features that generalise across both males and females [2]. Please note that we do not claim that debiasing is the clinically or ethically preferred solution here, we simply report the effect of one debiasing strategy using synthetic data. We view this as confirming that debiasing is complicated and requires careful consideration of mitigation strategies and their downstream effects [1].\n\n[1] Mittelstadt B, Wachter S, Russell C. The unfairness of fair machine learning: Leveling down and strict egalitarianism by default. Mich. Tech. L. Rev.. 2023;30:1.\n\n[2] Vigneshwaran et al. “Evaluating Shortcut Utilization in Deep Learning Disease Classification through Counterfactual Analysis,” in Medical Imaging with Deep Learning, Jan. 2025.\n\n**4.** We agree that not every contribution needs to be methodological and are pleased that the reviewer recognises the value of our dataset and large-scale analysis. We nevertheless maintain that our systematic evaluation provides a reusable framework for assessing model design choices, image editing capabilities, and identity preservation. \n\n**5.** We agree that image-quality metrics alone do not establish clinical utility. For this reason, we extended our clinical expert study comparing RadiT with Sana baselines, providing clear evidence of the greater clinical realism of our synthetic samples ( see our “Official Comment”). Our downstream classification experiments further show that RadiT synthetic data can substantially improve pathology detection performance. Together, these results provide complementary evidence of both clinical realism according to experts and downstream utility. That said, repeating the downstream experiments with synthetic data from the Sana baselines would be a useful addition and will be included in the final version.\n\n**6.** There appears to be a misunderstanding. Our statement that *“512x512 resolution was used in all **our** evaluations”* refers only to experiments conducted in our study, not to the benchmark results by Dutt et al., (2025). As stated in the caption of Table 3 in our submitted manuscript and in our initial rebuttal response, *“the original benchmark results are taken from CheXGenBench Dutt et al., (2025)”*. We will make this clearer in the final version.\n\n**(Continued below.)**"
+ },
+ "createdAt": "2026-08-02T15:45:51.920Z",
+ "modifiedAt": "2026-11-19T17:10:13.850Z",
+ "url": "https://openreview.net/forum?id=GDtwvgMFLg&noteId=eXyIU0yFpS",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/gdtwvgmflg/notes/j4mdjoycc6.json added

+++ b/reviews/openreview/gdtwvgmflg/notes/j4mdjoycc6.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "j4MdJoYcC6",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Expanded clinical user study",
+ "comment": "As suggested, we expanded our clinical user study to include comparisons with baseline models. For each model, we conducted a blinded and randomised **real-vs-synthetic classification** task in which a clinical expert evaluated 100 images (50 real/50 synthetic). We then compared the detectability of the synthetic images generated by each baseline with that of images generated by RadiT XL.\n\nWe evaluated two baseline models for synthetic CXR generation:\n\n**1. Sana (CheXGenBench).** We used the best-performing model reported in CheXGenBench (i.e. Sana). We followed the official CheXGenBench implementation and sampling configuration and used the official model checkpoint hosted on HuggingFace (`raman07/CheXGenBench-Models-Sana-e20`).\n\n**2. Sana (CXR7-1M).** We trained a Sana baseline on the CXR7-1M dataset using the official Sana codebase and the same training/hyperparameter configuration used for the Sana model in CheXGenBench.\n\nAs shown in the table below, the clinical expert identified synthetic images generated by both Sana baselines substantially more accurately than those generated by RadiT XL, demonstrating the higher realism of our model's outputs.\n\n**Table.** Performance of a clinical expert in the blinded **real-vs-synthetic classification** task. Synthetic images were treated as the positive class. Lower values indicate lower detectability of the synthetic images.\n\n| Model | Accuracy ↓ | Precision ↓ | Recall ↓ | F1 score ↓ |\n| ------------------- | ---------: | ----------: | --------: | ---------: |\n| **RadiT XL** | **0.540** | **0.538** | **0.590** | **0.557** |\n| Sana (CXR7-1M) | 0.820 | 0.820 | 0.820 | 0.820 |\n| Sana (CheXGenBench) | 0.790 | 0.738 | 0.900 | 0.811 |\n\nTogether with the subgroup analyses already added (finding, view, and demographics), these additional results aim to address concerns from gZvw, 9h1R, and the AC by extending the expert study beyond model ablations to include the strongest baseline. Because Sana CXR7-1M is trained on the same dataset as RadiT XL, the comparison isolates architectural improvements from data effects, addressing q2eR’s \"apple-to-apple\" concern. The large detectability gap (0.79-0.82 vs. 0.54, near chance) suggests the gains arise from the proposed model and training strategy rather than dataset scale alone."
+ },
+ "createdAt": "2026-07-30T15:52:17.988Z",
+ "modifiedAt": "2026-11-19T17:10:13.742Z",
+ "url": "https://openreview.net/forum?id=GDtwvgMFLg&noteId=j4MdJoYcC6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/gdtwvgmflg/notes/svqiqteihh.json added

+++ b/reviews/openreview/gdtwvgmflg/notes/svqiqteihh.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "sVqIqTeiHH",
+ "replyTo": "4qs6nCiDDH",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Reminder: Reviewer + Author Discussion Deadline",
+ "comment": "Dear Reviewer, \n\nThis is a friendly reminder that the **Author + Reviewer Discussion Period is ending on 3 August 23:59 AoE**. We would very much appreciate your feedback on any remaining questions you may have about our response. \n\nWe have shared a link to our code and model checkpoint with the AC, as requested. Please do reach out to the AC for access.\n\nWe are happy to clarify any further questions you might have about the code. \n\nThanks again for taking the time to review our work. \n\nBest regards,\n\nThe Authors"
+ },
+ "createdAt": "2026-08-03T14:50:08.515Z",
+ "modifiedAt": "2026-11-19T17:10:13.667Z",
+ "url": "https://openreview.net/forum?id=GDtwvgMFLg&noteId=sVqIqTeiHH",
+ "license": "CC-BY-4.0"
+}