potentialpaper

LFPformer: Geometry-Aware Self-Supervised Electrophysiology Representation Learning

Update NeurIPS 2026 submission hEiyAXz4A8: 24 notes

@openreview[bot] · 2026-11-24 15:54 UTC · f715b6ffffdc ·

Evidence

reviews/openreview/heiyaxz4a8/notes/9lonkwrcj9.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/9lonkwrcj9.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "9LoNKWrcj9",
+ "replyTo": "LF0Ebpx5Yj",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer uaNP (2/2)",
+ "comment": "### Q4\n*Insertion aware 3D localization decoding*\n\n**Response.**\nYes, we have done some successive experiments on this, where we use the IBL micro-manipulator\n(surgical) insertion trajectory: given the insertion-point coordinates $(x, y, z)$ (skull/bregma\nspace), insertion angles $(\\\\theta, \\\\phi)$, and insertion depth $d$, we reconstruct a straight probe\naxis from entry to tip, then place channels along that axis using the known Neuropixels geometry.\n\n**How we draw the manipulator path:**\n1. We start from here $(x, y, z, \\\\text{depth}, \\\\theta, \\\\phi)$.\n2. From the entry point $(x,y,z)$, angles $(\\\\theta,\\\\phi)$, and depth we obtain the tip;\n the probe axis is the straight line connecting entry and tip.\n $$\\\\mathrm{tip} = \\\\mathrm{entry} + \\\\mathrm{depth} \\\\cdot \\\\mathrm{direction}(\\\\theta, \\\\phi),$$\n3. Let $u = (\\\\mathrm{entry} - \\\\mathrm{tip}) / \\\\lVert \\\\mathrm{entry} - \\\\mathrm{tip} \\\\rVert$ be\n the unit vector along the shank.\n4. Place channel $i$ along that line with the NP1.0 spacing $\\\\Delta_s$ (20 $\\\\mu\\\\mathrm{m}$ per contact\n pair):\n $$p_i = \\\\mathrm{tip} + (i \\\\mathbin{//} 2) \\\\cdot \\\\Delta_s \\\\cdot u.$$\n5. Map $p_i$ into Allen CCF micrometers (approximate probe path).\n\nIf in the decoding stage we use LFP embeddings along with the channel coordinates from this\nIBL-manipulator line (as a prior / residual readout: $\\\\hat{c}_i = p_i + \\\\Delta_i$), it improves the\nRMSE compared to just using the manipulator line alone ($\\\\sim 922\\\\,\\\\mu\\\\mathrm{m}$) or just the LFP\nembeddings, reaching $\\\\sim 807\\\\,\\\\mu\\\\mathrm{m}$ on held-out probes. But we haven't tried using this information\nduring the pretraining stage itself. We agree that is a natural next step and fits the\ngeometry-aware framing for experimental adoption.\n\nBelow we show a table with some of the decoding experiments with the IBL micro-manipulator information.\nFrozen rows are mean $\\\\pm$ SD over 8 seeds. MicroManip is deterministic (surgical trajectory alone).\n| Regime | Head | Loss | Raw | Kabsch |\n| --- | --- | --- | ---: | ---: |\n| MicroManip | --- | --- | 920.9 | 922.0 |\n| Frozen | Linear | MSE | 915.1 ± 18.6 | 804.1 ± 3.3 |\n| Frozen | Linear | Gaussian | 864.3 ± 2.0 | 807.5 ± 5.7 |\n| Frozen | MLP | MSE | 923.2 ± 17.8 | 851.4 ± 17.9 |\n| Frozen | MLP | Gaussian | 896.9 ± 11.9 | 834.4 ± 11.0 |\n| Frozen | Transformer | MSE | 884.3 ± 36.1 | 872.8 ± 38.1 |\n| Frozen | Transformer | Gaussian | 848.7 ± 2.8 | 842.8 ± 5.0 |\n\nIn the above table, MicroManip shows the RMSE achieved by just drawing probe lines using the\nmicro-manipulator information (surgical insertion information). For the rest of the regimes we are\nusing the LFP embeddings from our MaskPred$+$ChanDistc (75k) model along with the insertion\ninformation.\n\nBased on the reviewer's comments, we have added additional experimental results and have addressed the concerns raised in the review. We again extend our gratitude to the reviewer for the careful feedback, which has helped strengthen the paper. We hope all of the above addresses the reviewer's concerns, and respectfully ask the reviewer to reconsider their score."
+ },
+ "createdAt": "2026-07-28T23:27:50.469Z",
+ "modifiedAt": "2026-11-19T16:53:08.859Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=9LoNKWrcj9",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/amsmtiawnz.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/amsmtiawnz.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "aMsmTiaWNZ",
+ "replyTo": "ETkHrsBMsv",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer erKH (part 2/6)",
+ "comment": "### Q2\n\nThe primary purpose of this model is to predict the location of each channel on the probe to help neuroscientists estimate trajectory while the probe is still inside the brain, without histology. A Neuropixels probe is a rigid physical object. It is physically impossible for channels on the same probe to independently scatter in three dimensional space.\n\nIf the predicted probe configuration were placed in its best fitting pose, how accurately would it localize the probe? This metric measures geometry consistent localization separately from global translation and rotation errors. Supervised baselines occasionally achieve lower raw coordinate errors on an isolated per channel basis, but their predictions lack internal geometric consistency. We still report mean error, median error, R squared, and correlation as complementary measures of absolute prediction quality.\n\n**Below is what the rewrite of the whole Kabsch Section in the refined version of this paper:**\n\n### Kabsch Refinement\n\nKabsch refinement takes exactly two inputs: the **known Neuropixels channel geometry layout** and the **model's own predictions**. **No ground-truth coordinates enter the fit.** Kabsch refinement enforces the constraint by snapping the template probe geometry onto the predicted coordinates. It can be read as imposing a strong geometric prior whatever the model predicts, the answer is required to be a physically realisable probe.\n\n**Setup.** Channel $i$ has a fixed offset on the shank, known from the device specification before any recording:\n\nLet $\\\\hat{\\\\mathbf{q}}_i$ be the predicted CCF coordinate for channel $i$. Per probe we find the rigid pose of the physical shank that best explains the predicted cloud:\n\n\\\\[ p_i=(x_{\\\\mathrm{col}}(i),\\\\,0,\\\\,d(i)),\\\\quad d(i)=20\\\\lfloor i/2\\\\rfloor\\\\,\\\\mu\\\\mathrm{m},\\\\quad\n x_{\\\\mathrm{col}}\\\\in\\\\{11,27,43,59\\\\}\\\\,\\\\mu\\\\mathrm{m}. \\\\]\n\n$$\\\\min_{\\\\mathbf{R} \\\\in SO(3),\\\\ \\\\mathbf{t}} \\\\sum_i \\\\| \\\\mathbf{R}\\\\mathbf{p}_i + \\\\mathbf{t} - \\\\hat{\\\\mathbf{q}}_i \\\\|^2 \\\\quad \\\\Longrightarrow \\\\quad \\\\hat{\\\\mathbf{q}}^{ref}_i = \\\\mathbf{R}\\\\mathbf{p}_i + \\\\mathbf{t}.$$\n\nThe solution is closed-form: centre both sets, form $\\\\mathbf{H}=\\\\sum_i(\\\\mathbf{p}_i-\\\\bar{\\\\mathbf{p}})(\\\\hat{\\\\mathbf{q}}_i-\\\\bar{\\\\mathbf{q}})^\\\\top$, take its SVD $\\\\mathbf{H} = \\\\mathbf{U}\\\\Sigma\\\\mathbf{V}^\\\\top$, and set $\\\\mathbf{R}=\\\\mathbf{V}\\\\,\\\\mathrm{diag}(1,1,\\\\det(\\\\mathbf{V}\\\\mathbf{U}^\\\\top))\\\\,\\\\mathbf{U}^\\\\top$, $\\\\mathbf{t}=\\\\bar{\\\\mathbf{q}}-\\\\mathbf{R}\\\\bar{\\\\mathbf{p}}$. Discarding $\\\\Sigma$ is what makes the transform *rigid*: the probe may rotate and translate but cannot stretch. Samples are weighted by the number of time-chunks per channel. We additionally enforce the known insertion direction (channel $0$ deeper in DV than channel $383$) by a $180^\\\\circ$ flip when the unconstrained fit returns an inverted pose."
+ },
+ "createdAt": "2026-07-28T23:21:40.165Z",
+ "modifiedAt": "2026-11-19T16:53:08.868Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=aMsmTiaWNZ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/atefgab9tu.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/atefgab9tu.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "AtefGab9TU",
+ "replyTo": "Whwyhj147E",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "## Author Follow-up Response — Reviewer exC2 (part 2/2)",
+ "comment": "**(3 continued) Takeaways.**\nPer-channel MLPs stay stuck around 2100 µm RAW and 1500–1580 µm Kabsch even when deepened. The MLP channel-mixer (3.4M; same channel sequence, but a global length-wise MLP instead of attention) reaches approximately 1580 µm RAW / 1537 µm Kabsch. A parameter-matched transformer (1 blk / d96 / h4 / ff192; 160k vs 198k MLP) already gets 1525 /1431 — about 540 µm better RAW and 150 µm better Kabsch than that MLP, and still ahead of the larger mixer (d128 / h8 ~250k is similar). So it is not just mixing or more params, the gain comes from *self-attention* over the channel sequence.\n\n**(4) Recommended config + insertion trajectory.**\nYes, for LFP-only we recommend the transformer decoder (4 blk / d256 / h8 / ff512) over other decoders like MLP and Linear layers. With insertion / micro-manipulator info (Reviewer uaNP; 8 seeds):\n\n*Table: Frozen 75k + Micro-manipulator metadata (8 seeds) from Table 2 uaNP review response. RMSE in µm.*\n\n| Regime | Head / Loss | Raw | Kabsch |\n| --- | --- | ---: | ---: |\n| MicroManip alone | — | 920.9 | 922.0 |\n| Frozen+MicroManip | Linear / Gaussian | 864.3 ± 2.0 | 807.5 ± 5.7 |\n| Frozen+MicroManip | Transformer / Gaussian | 848.7 ± 2.8 | 842.8 ± 5.0 |\n\nTransformer+MicroManip is best on RAW; Linear+MicroManip best on Kabsch (~808 µm). MicroManip fusion is optional when surgical metadata exist. We will not claim absolute SOTA without matched external baselines; transformer (LFP-only) + optional MicroManip is our recommended stack, both elevated in the revision.\n\n### A3.2 — Zero-shot k-NN protocol + k\n\nYes, your description is essentially correct. A few details: the neighbor bank is built from the training split only (evaluation embeddings are queries and never enter the bank); we compare frozen-backbone embeddings of LFP chunks; and no XYZ / CCF head is used. For each query we take the k nearest training neighbors by cosine similarity and assign the majority label.\n\nWe choose k from {1,3,5,10,20} on validation. For NeuroNexus we run a 7-fold session hold-out (each fold leaves out one recording session as the test set and picks k on that fold's validation split by maximizing validation accuracy). The Figure 4 bar is the mean±std of test balanced accuracy across the 7 folds at each fold's selected k (0.501±0.068; selected k: 20, 5, 10, 10, 20, 3, 3). For macaque, a single k is chosen on a within-Subject-A 90/10 validation split by maximizing validation balanced accuracy on the three in-distribution areas (k=20); the Figure 4 bar in the main paper is Subject-B test balanced accuracy on the three in-distribution areas at that k (0.337; same 3-class evaluation as in the paper). Validation-vs-k tables are below; we have added this protocol breakdown to the revised manuscript.\n\n*NeuroNexus val accuracy vs k and best_k (each fold holds out one session as test).*\n\n| Fold | k=1 | k=3 | k=5 | k=10 | k=20 | best_k |\n| ---: | ---: | ---: | ---: | ---: | ---: | ---: |\n| 1 | 0.642 | 0.673 | 0.688 | 0.703 | 0.719 | 20 |\n| 2 | 0.621 | 0.641 | 0.645 | 0.644 | 0.645 | 5 |\n| 3 | 0.569 | 0.580 | 0.582 | 0.586 | 0.585 | 10 |\n| 4 | 0.696 | 0.712 | 0.717 | 0.717 | 0.716 | 10 |\n| 5 | 0.638 | 0.653 | 0.652 | 0.656 | 0.658 | 20 |\n| 6 | 0.645 | 0.660 | 0.658 | 0.657 | 0.659 | 3 |\n| 7 | 0.646 | 0.661 | 0.659 | 0.660 | 0.661 | 3 |\n\n*Macaque Subject-A val bal_acc vs k (3-class, as in the paper).*\n\n| k=1 | k=3 | k=5 | k=10 | k=20 | best_k |\n| ---: | ---: | ---: | ---: | ---: | ---: |\n| 0.332 | 0.337 | 0.338 | 0.343 | 0.346 | 20 |\n\n### A4 — Batch size / workers for reported timings\n\nThank you. Yes, earlier timings used batch size 64 and 4 workers on an A100 (~1.88 ms/sample). We re-ran the full IBL test set (119 probes, 500k chunks) with batch size 1 and 1 CPU worker, same 75k MaskPred+ChanDistc FT checkpoint (H200). Stages: preprocess/resample, backbone, head, Kabsch.\n\nWe also report FLOPs (count one 3 s chunk × 500k).\n\n*Runtime + FLOPs on full 119-probe / 500k-chunk test (H200; bs=1, nw=1). 75k MaskPred+ChanDistc FT, linear head.*\n\n| Stage | Total time | ms/samp | ms/probe | % | GFLOP/chunk | GFLOP/500k |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| Preprocess (GPU resample) | 202.5 s (3.4 min) | 0.405 | 1701.7 | 7.9% | 0.002 | 9.13×10² |\n| Audio backbone forward | 2311.8 s (38.5 min) | 4.624 | 19426.8 | 90.5% | 41.56 | 2.078×10⁷ |\n| Coordinate head | 41.1 s | 0.082 | 345.6 | 1.6% | <0.001 | 6.91 |\n| Test-time Kabsch (CPU) | 0.4 s | 0.001 | 3.3 | ~0.0% | — | — |\n| **TOTAL** | **2555.8 s ≈ 42.6 min** | **5.112** | **21477.5** | **100%** | **41.56** | **2.078×10⁷** |\n\nEven at bs=1, a 3 s chunk takes 5.1 ms ≪ physical recording, so real-time still holds. Backbone dominates (~90.5% wall; 41.56 GFLOPs/chunk ≈ 2.078×10⁷ GFLOPs ≈ 20.78 PFLOPs over 500k). Head and Kabsch are negligible.\n\nWe have updated the revised manuscript with these new ablations. Thank you for the careful follow-up."
+ },
+ "createdAt": "2026-07-31T09:10:08.017Z",
+ "modifiedAt": "2026-11-19T16:53:08.403Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=AtefGab9TU",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/b8kwi30igu.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/b8kwi30igu.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "B8kwi30IGu",
+ "replyTo": "uncmSy3YuX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer erKH (part 6/6)",
+ "comment": "### Q5 (continued)\n\n**Brain Region Classification:** For depth-9 classification involving 309 fine parcels, our localization RMSE is still on the order of 1-1.5 mm, while many fine Allen parcels are only hundreds of micrometers wide. Therefore, an absolute balanced accuracy of 5-7% is well above chance but is not reliable for fine anatomical identification.\n\nWe will clarify that the primary readout for this paper remains 3D RMSE, with region lookup acting as a secondary quantized view. Depth-9 balanced accuracy is approximately 5-7%, compared with a chance level of 0.32%. See Table 7 for depths 3-9.\n\nBeyond spatial resolution, this raises an interesting neurobiological question: classical anatomical nomenclature may not perfectly align with electrophysiological boundaries. It is plausible that anatomically distinct brain regions share similar local-field-potential signatures, naturally leading the model to cluster them together, and vice versa. We are currently formalizing a null hypothesis to investigate rigorously the mapping between defined anatomy and raw electrophysiology.\n\nAlthough the current fine-grained accuracy is low, our explicit intention with this 309-class task is to establish a transparent foundational baseline for the community. By open-sourcing our pipeline and the Allen CCF topological map used for our class divisions, we hope to provide a rigorous benchmark that future researchers can build upon and surpass.\n\n**Table 7.** Balanced accuracy across anatomical depth levels (Depths 3--9) for MaskPred+ChanDistc with a frozen transformer head. Predictions follow raw Gaussian decoding, inverse-variance channel averaging, Kabsch refinement, and Allen atlas lookup. Chance is 1/#classes. Values are mean±SD over 8 seeds.\n\n| **Depth** | **# Cls** | **Chance (%)** | **25k** | **75k** | **301k** | **1M** |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| 3 | 31 | 3.23 | 14.85±0.54 | 15.65±1.01 | 15.90±0.73 | 15.67±0.66 |\n| 4 | 56 | 1.79 | 12.46±1.23 | 13.04±0.70 | 13.24±0.74 | 13.30±0.60 |\n| 5 | 107 | 0.93 | 10.06±1.60 | 11.17±0.84 | 11.32±0.81 | 12.46±0.95 |\n| 6 | 179 | 0.56 | 9.07±1.16 | 8.69±1.26 | 8.87±0.82 | 10.54±0.83 |\n| 7 | 225 | 0.44 | 8.25±1.02 | 7.80±1.18 | 7.51±0.60 | 8.93±0.68 |\n| 8 | 287 | 0.35 | 7.09±0.97 | 6.61±1.09 | 6.43±0.55 | 7.38±0.48 |\n| 9 | 309 | 0.32 | 6.66±0.95 | 6.46±1.00 | 6.17±0.62 | 6.97±0.51 |\n\n**Baseline Comparisons and Significance Tests:** We compared our histology-free method (MaskPred+ChanDistc) directly with the published lfp2vec baseline (MaskPred alone) using raw 3D localization error on the same held-out test probes.\n\nTo verify reliability, we repeatedly resampled those probes using 5,000 bootstrap draws. At the 75k, 301k, and 1M pretraining scales (Table 1), our method was better by approximately 86, 117, and 200 μm, respectively, and the 95% confidence intervals did not include zero. These results are marked with stars in the revised table to indicate statistical significance.\n\nAt 25k, the confidence interval included zero, so we do not claim statistical significance at the smallest scale.\n\nWe appreciate the reviewer's careful reading. The experiments and clarifications above respond directly to the points raised, and we believe they substantially improve the manuscript. We kindly ask that the reviewer's evaluation be updated in light of these additions."
+ },
+ "createdAt": "2026-07-28T23:28:51.974Z",
+ "modifiedAt": "2026-11-19T16:53:08.975Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=B8kwi30IGu",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/etkhrsbmsv.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/etkhrsbmsv.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "ETkHrsBMsv",
+ "replyTo": "JgpVSGZCrj",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer erKH (part 1/6)",
+ "comment": "We sincerely thank Reviewer erKH for their rigorous assessment. We have organized this rebuttal to address each of your concerns directly. First, we clarify the critical misunderstanding regarding ground truth usage during our inference time Kabsch refinement, confirming absolutely zero data leakage. Second, we justify our geometric metric selection. Third, we detail our strict subject level data splits. Fourth, we correct the text figure discrepancies regarding the Macaque evaluation and model scaling trends. Finally, we resolve the remaining questions regarding hyperparameter searches, region counts, explicit limitations, and provide the requested baseline comparisons with statistical significance tests. We would be grateful if the reviewer could consider this additional evidence when revisiting their assessment.\n\n### Q1\n\nAbsolutely zero ground truth coordinates are used during our inference time refinement. The Kabsch fit relies solely on inference time metadata: the known on probe Neuropixels channel geometry (column X and inter channel depth spacing) mapped onto the model's predicted XYZ positions. We sincerely apologize for the typographical error in Appendix D.3; this text mistakenly described an earlier oracle bounding experiment and is completely rewritten to accurately describe the metadata driven projection.\n\nTo address your request, all main results are now reported both with and without refinement in Table 1. In the table the **Oracle** column is the RMSE we get if we use GT coordinates for Kabsch instead of probe geometry information. We can see that all the RMSE values for all models and scales gives 107.2 $\\mu m$ RMSE if we use the GT coordinates.\n\n**Table 1.** 3D localization RMSE (μm) before (RAW) and after Kabsch refinement, across pretraining scales. MaskPred is the lfp2vec baseline; MaskPred+CCFDistc is the histology-supervised geometric upper bound; MaskPred+ChanDistc is our histology-free method. All methods use a frozen backbone with a linear Gaussian head. Kabsch fits the rigid probe pose to *predicted* CCF (GT used only for RMSE). Oracle Kabsch fits the same rigid pose to *true* CCF coordinates (GT in the fit; diagnostic floor). Values are mean ± SD over 8 seeds.\n\n| Scale | MaskPred RAW | MaskPred Kabsch | MaskPred Oracle | +CCFDistc RAW | +CCFDistc Kabsch | +CCFDistc Oracle | +ChanDistc RAW | +ChanDistc Kabsch | +ChanDistc Oracle |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: | ---: | ---: | ---: |\n| 25k | 2291.6±0.4 | 1999.2±0.3 | 107.2±0.0 | 2081.3±0.5 | 1572.5±0.6 | 107.2±0.0 | 2259.6±4.0 | 1827.6±5.7 | 107.2±0.0 |\n| 75k | 2246.3±0.4 | 1954.7±2.0 | 107.2±0.0 | 2039.1±0.4 | 1520.4±0.4 | 107.2±0.0 | 2160.2±2.6* | 1769.1±5.2 | 107.2±0.0 |\n| 301k | 2236.6±0.4 | 1942.7±0.7 | 107.2±0.0 | 1972.4±0.2 | 1438.4±0.3 | 107.2±0.0 | 2119.4±1.8* | 1677.1±2.4 | 107.2±0.0 |\n| 1M | 2293.8±0.4 | 1975.7±2.0 | 107.2±0.0 | 1989.5±0.2 | 1482.1±0.2 | 107.2±0.0 | 2093.8±1.0* | 1661.3±3.1 | 107.2±0.0 |"
+ },
+ "createdAt": "2026-07-28T23:05:27.190Z",
+ "modifiedAt": "2026-11-19T16:53:08.885Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=ETkHrsBMsv",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/fjwosgu7qt.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/fjwosgu7qt.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "FjwosGU7qT",
+ "replyTo": "9LoNKWrcj9",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer uaNP",
+ "content": {
+ "comment": "I thank the authors for engaging with my review in such detail. Their replies address many of my concerns. In particular, clarifying that the baseline is the previous method including the same losses, adding the new scaling analysis, and the new insertion-aware initialization results all strengthen the paper. I am raising my score to 4.\n\nOne request remains. Could the authors add a section that positions their novelty relative to prior work, and that sketches how the approach could be extended in the future? On the latter, the direction I have in mind is a model that takes as input the probe layout, a brain atlas for the relevant species, the LFP, and optionally the insertion location and angle, and returns a 3D coordinate for each channel with error estimate. It seems entirely reasonable to me if such a model were trained in part on histology-labeled data, as that supervision may well improve inference performance at test time, when histology is not available.\n\nHaving both pieces in the paper, an explicit statement of what is new here, and an indication of the path along which this could be scaled or generalized, will be critical for readers to interpret the contribution."
+ },
+ "createdAt": "2026-08-03T01:49:57.842Z",
+ "modifiedAt": "2026-11-19T16:53:08.323Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=FjwosGU7qT",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/fucnqtvqxs.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/fucnqtvqxs.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "fUCNqTVQXS",
+ "replyTo": "AtefGab9TU",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer exC2",
+ "content": {
+ "comment": "Thank you for the careful follow-up in the rebuttal, I particularly appreciate:\n\n**(A1)** The added inference on the window-length tradeoff.\n\n**(A2)** The clarification, the additional experiment disentangling the gains from the transformer head (by scaling the MLP head parameter count), and the extra result combining the transformer head with the insertion trajectory.\n\n**(A3)** The detailed description of the zero-shot k-NN protocol and the reported results across different values of k.\n\n**(A4)** The corrected batch size and number of workers for the reported timings.\n\nAll of my points have been addressed and I maintain my positive assessment on the paper."
+ },
+ "createdAt": "2026-08-02T01:59:23.810Z",
+ "modifiedAt": "2026-11-19T16:53:08.332Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=fUCNqTVQXS",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/ga3rjylims.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/ga3rjylims.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "gA3rJyliMS",
+ "replyTo": "rjPuUV37LU",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer erKH (part 4/6)",
+ "comment": "### Q3\n\nThe splits are strictly separated at the subject level. 139 unique animals are partitioned into three disjoint pools. Because the partition is at the animal level, no animal, recording session, or probe ever appears in more than one pool. We verified that all pairwise intersections are empty at the subject, session, and probe levels. There is therefore no same animal or same session leakage from training into evaluation. Our test performance is a true held out animal generalization measurement. (The same split was shown in Figure 6 ((a) and (b)) in the paper, and we will add the table below explicitly to avoid any confusion)\n\n**Table 3.** Allen Brain Observatory, subject-level partition.\n\n| **Split** | **Sessions** | **Specimens(mice)** | **Probes/insertions** |\n| --- | ---: | ---: | ---: |\n| Train | 25 | 25 | 133 |\n| Val | 14 | 14 | 80 |\n| Test | 12 | 12 | 61 |\n| **TOTAL** | **51** | **51** | **274** |\n\n**Table 4.** IBL Brain-Wide Map, subject-level partition.\n\n| **Split** | **Subjects** | **Sessions(eids)** | **Probes/insertions** |\n| --- | ---: | ---: | ---: |\n| Train | 76 | 281 | 439 |\n| Val | 29 | 98 | 141 |\n| Test | 34 | 80 | 119 |\n| **TOTAL** | **139** | **459** | **699** |\n\n### Q4\n\nRegarding the Macaque evaluation, Figure 4 is correct: HistGBM achieves the highest balanced accuracy on this dataset. We apologize for the oversight in the main text. Our method performs worse in this specific setting because the macaque recordings introduce a cross species and cross dataset distribution shift that was not fully resolved by the learned representations given the limited training subjects (only 2 subjects 1 for Train and another for Test) available at the time of submission. We have corrected the main text claim.\n\nRegarding the monotonic trends, in the originally submitted table, the MaskPred and MaskPred+ChanDistc entries for Data2Vec were trained with unmatched hyperparameter settings (specifically different channel distance weights) and different training budgets, meaning the comparison was not controlled. We have rerun these cells so that the only difference is the presence of the channel distance objective (same architecture, training configuration, and MLP probe head). Under matched configurations, the improvement is now clearly monotonic with MaskPred+ChanDistc doing better than MaskPred for Data2Vec. Similarly we rerun Whisper small and it is also clearly monotonic, which was trained for very few epochs earlier, now sees clear improvement (See Table 5).\n\nWe have updated the table with the final numbers and ensure no discrepancy between tables (Table 4), text (Lines 216-218) and the graph (Figure 4(b)) in the refined verison of the paper.\n\n**Table 5.** **IBL probe-channel XYZ localisation at the 75k SSL scale.** Fold-LR RMSE (μm) after per-probe rigid alignment, as mean ± std across the 5 test folds. **frozen** = backbone frozen; **fullft** = all backbone parameters updated. PT = HF audio pretrained init; RI = random init. Lower is better.\n\n| Backbone | Pretraining | Eval | Init | Kabsch (μm) |\n| --- | --- | --- | --- | ---: |\n| data2vec | MaskPred | frozen | PT | 1958 ± 1 |\n| | | fullft | PT | 1718 ± 10 |\n| | MaskPred + ChanDistc | frozen | PT | **1780** ± 2 |\n| | | fullft | PT | **1690** ± 3 |\n| | MaskPred | frozen | RI | 1797 ± 2 |\n| | MaskPred + ChanDistc | frozen | RI | **1705** ± 3 |\n| | | fullft | RI | **1687** ± 7 |\n| whisper-small | MaskPred | frozen | PT | 2205 ± 3 |\n| | | fullft | PT | 2023 ± 2 |\n| | MaskPred + ChanDistc | frozen | PT | **2104** ± 3 |\n| | | fullft | PT | **1874** ± 2 |"
+ },
+ "createdAt": "2026-07-28T23:26:10.349Z",
+ "modifiedAt": "2026-11-19T16:53:08.964Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=gA3rJyliMS",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/h0nm7vwtmk.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/h0nm7vwtmk.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "H0Nm7vwTmk",
+ "replyTo": "SY3Er0ZIxg",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer uaNP",
+ "content": {
+ "comment": "Thank you for these clarifications. They mostly address my remaining concerns and I think the manuscript will be a good fit for the Neurips venue."
+ },
+ "createdAt": "2026-08-04T00:07:46.480Z",
+ "modifiedAt": "2026-11-19T16:53:08.290Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=H0Nm7vwTmk",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/lf0ebpx5yj.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/lf0ebpx5yj.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "LF0Ebpx5Yj",
+ "replyTo": "o9GfYgHoLy",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer uaNP (1/2)",
+ "comment": "We thank the reviewer for the careful and constructive feedback.\nWe address the main concerns below.\nIn particular:\n(i) the baseline MaskPred compared to our final model is the published\nlfp2vec objective from last year (masked contrastive loss $+$ diversity loss,\nnot masked modeling alone);\n(ii) we clarify the role of CCFDistc as a histologically\ndependent oracle/upper bound, and report how our histologically free ChanDistc method\nrelates to it under data scaling;\n(iii) we include experiments that use insertion/micro-manipulator\ninformation at readout, which shows that by adding lfp embeddings with insertion information we are able to get RMSE value of $\\\\sim 807\\\\,\\\\mu\\\\mathrm{m}$ which is lowest RMSE we have got.\nWe will also revise the figures for readable labels and colors, and\nstate the main findings clearly in the Results section in the main paper. We hope these additions address the reviewer's concerns and would be grateful if they could be considered when revisiting the score.\n\n### Q1\n*MaskPred is lfp2vec model*\n\n**Response.**\nYes: when we compared our method, which is MaskPred$+$ChanDistc, to the baseline\nMaskPred-only method, it is the lfp2vec method from He et al. [1], and it uses the contrastive\nloss and the diversity loss that is present in the wav2vec 2.0 architecture -- it is not simply\njust masked prediction. We are sorry for the misunderstanding caused and we will rectify it in the paper (Section 3.3.1 Lines 109-115) by clarifying that the name is MaskPred but it actually uses all the losses used in the\noriginal wav2vec 2.0 architecture and the lfp2vec paper. In code we use temporal contrastive\nInfoNCE on masked timesteps $+$ codebook diversity, along with audio-initialized weights. For\nFig. 5, the transferred backbone is our MaskPred$+$ChanDistc model; MaskPred-only rows in other\nbackbone comparisons use this full lfp2vec SSL objective, not reconstruction-only masked modeling.\n\n### Q2 & Q3\n*CCFDistc is the Oracle model for localization*\n\n**Response.**\nThank you for highlighting this. In the paper we are showing the result for CCFDistc as a way to\nshow the oracle, or highest performance we can get, if we directly use the atlas-registered CCF\ncoordinates of the channels (histology-dependent supervision during pretraining) to do contrastive\nlearning. This is not our final model because the very purpose of this project is to build a model\nthat does not use atlas-registered CCF coordinates of channels as supervised labels. Thank you very\nmuch for the suggestion of showing a single scaling analysis between our proposed method\nMaskPred$+$ChanDistc and MaskPred$+$CCFDistc (CCFDistc $=$ supervised geometric upper bound;\nChanDistc $=$ histology-free method), on a shared metric and axis. It is a core comparison that will\nelevate our paper. Below we show a table of this scaling analysis.\n\n**Table 1**: 3D localization RMSE ($\\\\mu\\\\mathrm{m}$) before (RAW) and after Kabsch refinement, across pretraining scales. MaskPred is the lfp2vec baseline; MaskPred$+$CCFDistc is the histology-supervised geometric upper bound; MaskPred$+$ChanDistc is our histology-free method. All methods use a frozen backbone with a linear Gaussian head. Kabsch fits the rigid probe pose to *predicted* CCF (GT used only for RMSE). Oracle Kabsch fits the same rigid pose to *true* CCF coordinates (GT in the fit; diagnostic floor). Values are mean $\\\\pm$ SD over 8 seeds.\n\n| Scale | MP RAW | MP Kab | MP Ora | +CCF RAW | +CCF Kab | +CCF Ora | +CD RAW | +CD Kab | +CD Ora |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: | ---: | ---: | ---: |\n| 25k | $2291.6\\\\pm0.4$ | $1999.2\\\\pm0.3$ | $107.2\\\\pm0.0$ | $2081.3\\\\pm0.5$ | $1572.5\\\\pm0.6$ | $107.2\\\\pm0.0$ | $2259.6\\\\pm4.0$ | $1827.6\\\\pm5.7$ | $107.2\\\\pm0.0$ |\n| 75k | $2246.3\\\\pm0.4$ | $1954.7\\\\pm2.0$ | $107.2\\\\pm0.0$ | $2039.1\\\\pm0.4$ | $1520.4\\\\pm0.4$ | $107.2\\\\pm0.0$ | $2160.2\\\\pm2.6$ | $1769.1\\\\pm5.2$ | $107.2\\\\pm0.0$ |\n| 301k | $2236.6\\\\pm0.4$ | $1942.7\\\\pm0.7$ | $107.2\\\\pm0.0$ | $1972.4\\\\pm0.2$ | $1438.4\\\\pm0.3$ | $107.2\\\\pm0.0$ | $2119.4\\\\pm1.8$ | $1677.1\\\\pm2.4$ | $107.2\\\\pm0.0$ |\n| 1M | $2293.8\\\\pm0.4$ | $1975.7\\\\pm2.0$ | $107.2\\\\pm0.0$ | $1989.5\\\\pm0.2$ | $1482.1\\\\pm0.2$ | $107.2\\\\pm0.0$ | $2093.8\\\\pm1.0$ | $1661.3\\\\pm3.1$ | $107.2\\\\pm0.0$ |\n\nMP=MaskPred; +CCF=MaskPred+CCFDistc; +CD=MaskPred+ChanDistc. Kab=Kabsch; Ora=Oracle.\n\n**References**\n\n[1] He, T., Patel, M., Li, C., Maslarova, A., Vöröslakos, M., Ramanathan, N., Hung, W.-L., Buzsáki, G., & Varol, E. (2026). Self supervised learning for in vivo localization of microelectrode arrays using raw local field potential. Advances in Neural Information Processing Systems, 38, 124297-124320."
+ },
+ "createdAt": "2026-07-28T23:26:24.965Z",
+ "modifiedAt": "2026-11-19T16:53:08.964Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=LF0Ebpx5Yj",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/lhjhs1z7oi.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/lhjhs1z7oi.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "LHJhs1z7OI",
+ "replyTo": "JgpVSGZCrj",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer,\n\nAs the author-reviewer discussion period comes to an end, we wanted to reach out and thank you once again for your highly detailed and rigorous initial review.\n\nWe would greatly appreciate your feedback on the extensive new experiments and analyses we conducted based on your great suggestions. In our detailed rebuttal, we provided the requested statistical significance tests, ran strictly controlled ablation comparisons, and explicitly clarified our data splits.\n\nMost importantly, we hope our response successfully resolved the critical misunderstanding caused by our typographical error in the appendix, confirming that absolutely zero ground-truth data is ever used during our inference-time Kabsch refinement.\n\nIf you have a moment to review our responses and the newly provided tables, we would be incredibly grateful. We remain fully available to answer any remaining questions or address any further concerns you might have before the discussion phase closes.\n\nThank you for your time and continued guidance,\n\nThe Authors"
+ },
+ "createdAt": "2026-08-04T03:57:04.073Z",
+ "modifiedAt": "2026-11-19T16:53:08.524Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=LHJhs1z7OI",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/mpnhujbas4.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/mpnhujbas4.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "MpNhujbaS4",
+ "replyTo": "QnQ0jjjxaC",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer exC2 (part 5/6)",
+ "comment": "### Minor comments\n- **NeuroNexus in Section 2.**\n Thank you for pointing this out. NeuroNexus (and the macaque data) are used\n only for the brain-region decoding evaluation, not for SSL pretraining.\n We will mention them in Section 2 and point to the appendix for details.\n As clarified in A3.2, that evaluation is frozen-embedding cosine $k$-NN on\n region labels, not XYZ / Allen-CCF coordinate transfer.\n- **NeuroNexus, macaque, and chronic 5-day dataset details / availability.**\n We got the NeuroNexus dataset for region classification from [angotzi2025multishank]. The 5Day chronic dataset and macaque were shared with us by collaborator labs for transfer / zero-shot\n evaluation (and chronic stability) only.\n To keep the rebuttal anonymous, we cannot name the collaborators or give\n identifying raw-data details here; we will add proper references and\n availability notes in the camera-ready revision.\n How we use them:\n\n ***NeuroNexus*** (mouse multi-shank silicon probes) ---\n 5-class region classification (Cortex, CA1, CA2, CA3, DG).\n Evaluation uses a *session-disjoint* leave-one-session-out /\n session-rotation split (held-out session = test; remaining sessions =\n train/val). Subject-disjoint splits are *not* enforced: session\n prefixes span multiple animals (AD_HF01/02/03), and some sessions\n share an animal. Supervised LOSO additionally uses a within-session\n trial split (60 trials/session → 36/12/12). This is the only dataset where the subject wise split does not hold.\n We score frozen embeddings from our IBL-pretrained MaskPred$+$ChanDistc\n backbone with cosine $k$-NN.\n\n | | |\n | --- | --- |\n | Species / probe | mouse; multi-shank NeuroNexus silicon |\n | Sessions used | 7 |\n | Classes | 5 (Cortex, CA1, CA2, CA3, DG) |\n | Trials / session | 60 (train/val/test = 36/12/12) |\n | LFP rate / chunk | 1250 Hz; 3 s (3750 samples) |\n | Labeled channels / session | 130, 339, 473, 515, 553, 555, 647 |\n | Total (ch×trial) chunks | 192,720 |\n | CCF XYZ | none (region labels only) |\n | Split | session-disjoint LOSO; not enforced subject-disjoint |\n\n ***Macaque*** (Neuropixels, prefrontal cortex) ---\n subject-level transfer: Subject A = train/reference, Subject B (different\n animal) = held-out test.\n Scored task = 3-class region classification (area_45, area_8, area_9|46);\n other probes/labels are OOD and are not counted in the headline metric.\n\n | | |\n | --- | --- |\n | Species / probe | macaque; Neuropixels 1.0 NHP (NP1032; 384 LFP + 1 sync) |\n | Subjects | A (2 sessions) → B (1 session, different animal) |\n | Recording length (SpikeGLX fileTimeSecs) | A: 6600.47 s + 8836.78 s (= 15437.25 s; 4.288 h); B: 10638.83 s (2.955 h) |\n | Probes / session | 4 |\n | Native LFP rate | 2500.01 Hz |\n | Chunking | 3 s (≈7500 samples @ native rate; resampled for our encoder) |\n | 3 s chunks / probe | A: 2200 + 2945 = 5145; B: 3546 |\n | Headline classes | 3 in-dist (area_45, area_8, area_9|46) |\n | CCF XYZ | none |\n | Split | subject-disjoint A→B; within-A 90/10 for val |\n\n ***Chronic 5-day Neuropixels*** (Appendix I / Fig. 10) ---\n different from the NeuroNexus transfer set above.\n Used only for zero-shot chronic stability: IBL-trained encoder + Gaussian\n xyz head applied directly after destriping / resampling; no histology GT\n (qualitative region-assignment stability).\n\n | Session day | Duration (s) | Duration (h) |\n | --- | ---: | ---: |\n | Day 1 (Jul) | 14035.62 | 3.899 |\n | Day 2 (Jul) | 15444.49 | 4.290 |\n | Day 3 (Jul) | 13819.99 | 3.839 |\n | Day 4 (Oct) | 16040.58 | 4.456 |\n | Day 5 (Oct) | 10532.51 | 2.926 |\n | Total | 69873.20 | 19.409 |\n\n | | |\n | --- | --- |\n | Species / probe | mouse; chronically implanted Neuropixels 2.0 (NP2010; 384 ch) |\n | Sessions | 5 days on the same implant |\n | Calendar span | 2.5 months (Jul 29--31 and Oct 14--15, 2024) |\n | Native LF → model input | 2500 Hz → 1250 Hz |\n | Eval chunk | 3 s / channel (23288 chunks/channel; 8,942,592 ch×chunk @ 384) |\n | Ground truth | no histology-aligned CCF; qualitative stability only |\n | Role | Appendix I zero-shot chronic stability (not Fig. transfer bars) |"
+ },
+ "createdAt": "2026-07-28T23:42:22.616Z",
+ "modifiedAt": "2026-11-19T16:53:08.526Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=MpNhujbaS4",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/nqhot7r1nt.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/nqhot7r1nt.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "NQHoT7R1Nt",
+ "replyTo": "QnQ0jjjxaC",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer exC2 (part 4/6)",
+ "comment": "### A4 --- Runtime breakdown and real-time feasibility\n\nTo demonstrate the real time feasibility of our method, we timed the end to end inference pipeline on the complete IBL test set. This evaluation set consists of five subject split folds comprising 500,000 channel by time chunks across 119 test probes. Because each chunk represents a 3 second LFP window sampled at 1250 Hz, the total evaluated dataset covers exactly 416.7 hours of neural signal.\n\nThe inference pipeline executes in four distinct stages. First, the GPU preprocesses and resamples the signal from 1250 Hz to 16 kHz. Second, the wav2vec2 audio backbone encodes the signal into a mean pooled 768 dimensional embedding. Third, the Gaussian coordinate heads process the embeddings. Finally, the CPU executes the Kabsch rigid probe geometry refinement, which fits the known on probe channel geometry to the predictions.\n\n**Table 3**: Inference runtime on the full 119-probe / 500k-chunk test set (A100-80GB).\nModel: 75k MaskPred+ChanDistc full fine-tune with linear head\n\n| Stage | Total time | ms / sample | ms / probe | % of pipeline |\n| --- | --- | ---: | ---: | ---: |\n| Preprocess (GPU resample) | 4.4 s | 0.009 | 36.7 | 0.5% |\n| Audio backbone forward | 933.9 s (15.6 min) | 1.868 | 7848.0 | 99.4% |\n| Coordinate head | 1.3 s | 0.003 | 11.1 | 0.1% |\n| Test-time Kabsch refinement (CPU) | 0.3 s | 0.001 | 2.6 | ~0.0% |\n| **TOTAL** | **939.9 s ≈ 15.7 min ≈ 0.26 h** | **1.880** | **7898.4** | **100.0%** |\n\n**Test-set size**\n- Probes: 119 (test probes)\n- Channel×time chunks: 500,000\n- Chunk duration: 3 s @ 1250 Hz\n- Total signal covered: 1,500,000 s = 25,000 min = 416.7 h\n- Inference wall-clock (above): 939.9 s ≈ 15.7 min on one A100\n\nAs detailed in the table, processing a 3 s chunk takes approximately 1.88 ms on a single A100 GPU. The audio backbone accounts for\nthe vast majority of this cost (~99.4%), while the coordinate head and Kabsch refinement are negligible. Because inference is\norders of magnitude faster than the physical signal duration, the pipeline is real-time capable for live channel localization during\nrecording. Heavier MLP/transformer decoders increase head cost relative to the linear case, inference can be further accelerated by\nbatching across chunks/probes and, if needed, multi-GPU parallelism."
+ },
+ "createdAt": "2026-07-28T23:38:05.361Z",
+ "modifiedAt": "2026-11-19T16:53:08.842Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=NQHoT7R1Nt",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/qnq0jjjxac.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/qnq0jjjxac.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "QnQ0jjjxaC",
+ "replyTo": "ntb4Om7i3n",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer exC2 (part 1/6)",
+ "comment": "We thank reviewer exC2 for the careful and constructive feedback.\nWe have gone through each of the points raised and added the experiments and\nclarifications requested. In brief, we now include a temporal window-size\nablation showing that longer windows improve localization at higher training\ncost; a head and loss ablation comparing Gaussian vs. MSE and linear vs. MLP\nand transformer readouts, Gaussian and MSE are broadly similar with no clear\nwinner, while the transformer decoder clearly outperforms MLP and linear heads;\nclearer descriptions of region lookup vs. classification, ChanDistc vs.\nCCFDistc, our zero-shot cross-species protocol; and an end-to-end inference\nruntime breakdown confirming real-time feasibility (about $1.8$ ms per $3$ s\nchunk for the linear head on one A100). We answer each question below and sincerely appreciate the reviewer's thoughtful comments and welcome any additional feedback.\n\n### A1 --- Choice of the 3-second window and window-size ablation\n\nWe evaluated our method using a 3-second window size primarily to maintain strict parity with the lfp2vec baseline (referred to as MaskPred in our manuscript), ensuring a direct and controlled performance comparison.\n\n**Table 1**: 25k MaskPred$+$ChanDistc --- input window size ablation on IBL Test set (frozen linear head).\n\n| Input Window Sizes | Raw Gauss (µm) | Kabsch Gauss (µm) | Raw MSE (µm) | Kabsch MSE (µm) | Minutes/epoch (SSL) (25k) |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| 1 second | 2381.2 | 2067.5 | 2375.1 | 2020.2 | 1.9 |\n| 2 seconds | 2280.0 | 1939.6 | 2290.2 | 1901.3 | 5.1 |\n| 3 seconds | 2271.8 | 1909.4 | 2272.6 | 1862.1 | 6.5 |\n| 5 seconds | 2153.4 | 1776.3 | 2147.9 | 1751.1 | 9.4 |\n| 10 seconds | 2093.5 | 1734.6 | 2055.6 | 1647.8 | 18.9 |\n\nAs demonstrated in the ablation table, extending the temporal window to 5 or 10 seconds yields progressive improvements in\nlocalization accuracy. However, this gain comes at higher computational cost, as training time scales with window length; running the\nfull 1M-scale regime at 10 s would be time consuming. The 3 s window therefore offers a practical trade-off between accuracy and\ncompute for this study, and we expect joint scaling of data and window length to further lower RMSE. We will include this ablation in\nthe revised paper (main text summary, full table in the Appendix)."
+ },
+ "createdAt": "2026-07-28T23:34:47.232Z",
+ "modifiedAt": "2026-11-19T16:53:08.929Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=QnQ0jjjxaC",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/rjpuuv37lu.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/rjpuuv37lu.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "rjPuUV37LU",
+ "replyTo": "ETkHrsBMsv",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer erKH(part 3/6)",
+ "comment": "### Q2 (continued)\n\n**Kabsch refinement examples:**\n\nTo give a working example: Table 2, $\\\\bar{\\\\mathbf{q}}=(6032,2081,480)$ is the mean of the six predictions and $\\\\mathbf{t}=(6056,2098,506)$; channel $0$'s refined position is $\\\\mathbf{R}(11,0,0)+\\\\mathbf{t}=(-7.8,-7.5,-2.1)+\\\\mathbf{t}=(6048,2090,504)$. Note the refined value is computed from the *template* point $(11,0,0)$, not from channel $0$'s own prediction: individual predictions enter only through $\\\\bar{\\\\mathbf{q}}$ and $\\\\mathbf{H}$.\n\nThe effect is to enforce hardware constraints. Channels $0$ and $1$ are $32\\\\,\\\\mu$m apart on the physical probe; the raw predictions place them $647\\\\,\\\\mu$m apart, which is anatomically impossible. After fitting they are $32\\\\,\\\\mu$m apart again, and the RMSE for this probe improves from $301$ to $56\\\\,\\\\mu$m.\n\n**Table 2.** Kabsch refinement, worked example (6 channels, μm). The template is the manufactured channel layout; refined positions are $\\\\mathbf{R}\\\\mathbf{p}_i+\\\\mathbf{t}$, computed from the template and the predicted centroid only.\n\n| | **ch0** | **ch1** | **ch2** | **ch3** | **ch4** | **ch5** |\n| --- | --- | --- | --- | --- | --- | --- |\n| Template $\\\\mathbf{p}_i$ | (11,0,0) | (43,0,0) | (27,0,20) | (59,0,20) | (11,0,40) | (43,0,40) |\n| Predicted $\\\\hat{\\\\mathbf{q}}_i$ | (6332,2179,514) | (5705,2050,421) | (6017,1987,502) | (5976,1864,658) | (6183,2408,543) | (5981,2002,245) |\n| **Refined $\\\\hat{\\\\mathbf{q}}^{ref}_i$** | (6048,2090,504) | (6025,2068,497) | (6036,2085,481) | (6014,2063,475) | (6047,2102,465) | (6024,2080,459) |\n\n**Inputs and outputs.** To state the data flow explicitly, the procedure maps\n\n$$\\\\{\\\\mathbf{p}_i\\\\} \\\\ , \\\\ \\\\{\\\\hat{\\\\mathbf{q}}_i\\\\} \\\\ \\\\longmapsto \\\\ \\\\{\\\\hat{\\\\mathbf{q}}^{ref}_i\\\\}, \\\\qquad \\\\hat{\\\\mathbf{q}}^{ref}_i = \\\\mathbf{R}\\\\mathbf{p}_i + \\\\mathbf{t}.$$\n\nwhere $\\\\{\\\\mathbf{p}_i\\\\}$ is the probe geometry template, $\\\\{\\\\hat{\\\\mathbf{q}}_i\\\\}$ are the model predictions, and $\\\\{\\\\hat{\\\\mathbf{q}}^{ref}_i\\\\}$ are the refined predictions.\n\nThis corrects for global translation and rotation errors that are consistent across all channels on a single probe insertion, isolating the model's ability to resolve *relative* channel positions along the probe trajectory."
+ },
+ "createdAt": "2026-07-28T23:23:30.353Z",
+ "modifiedAt": "2026-11-19T16:53:08.963Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=rjPuUV37LU",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/sy3er0zixg.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/sy3er0zixg.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "SY3Er0ZIxg",
+ "replyTo": "FjwosGU7qT",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "## Author Follow-up Response — Reviewer uaNP",
+ "comment": "We thank the reviewer for raising the score to 4, and for asking us to spell out what is new and where this line of work can go next. We will add both of the paragraphs below to the revision, novelty in the Introduction, and the future-path sketch in the Discussion.\n\n### Novelty relative to prior work\n\nEarlier LFP localization work, including lfp2vec (He et al., NeurIPS 2026), mainly asks the model to pick a discrete brain region. As far as we know, no published method does continuous heteroscedastic Gaussian 3D coordinate regression of channel (x,y,z) from LFP, that is the shift we are aiming for, a different target and a different inductive bias during pretraining.\n\nConcretely, we keep the published lfp2vec objective as MaskPred (masked contrastive loss plus diversity, with audio init), and add geometry-aware contrastive terms that push the embedding space to respect physical layout: ChanDistc uses on-probe channel geometry (no histology), CCFDistc uses atlas CCF when histology is available (oracle), and ManipDistc takes channel xyz from the micro-manipulator trajectory and applies the same distance-contrastive loss as ChanDistc / CCFDistc, just with that histology-free surgical geometry. lfp2vec itself flagged spatial priors in the loss as future work; that is the gap we are trying to fill. We also show that these priors help transfer across probe hardware and across species (mouse to primate). Finally, we scale the same geometry-aware SSL recipe to **1M-sample pretrained** checkpoints (MaskPred, MaskPred+ChanDistc, MaskPred+ManipDistc, and the MaskPred+CCFDistc oracle), so the contribution includes large-scale, release-ready backbones as well as the objectives themselves.\n\n### Future extensions\n\nWe like the reviewer's suggestion of a more general localizer, and we will put it in the Discussion essentially as stated. The natural next system would take several inputs at once, the raw LFP, the physical probe layout, a species brain atlas, and, when available, surgical priors such as insertion point and angles, and return a refined 3D coordinate plus a confidence interval for each channel.\n\nIn the revised paper, MaskPred+ManipDistc is our main model, the best histology-free pretraining we report. We will update the figures and tables around this model, and release its weights on HuggingFace for neuroscientists to use. We still report the other pretrainings as comparisons, and will make those checkpoints available as well if labs need them for their metadata setting: MaskPred alone (no geometry), MaskPred+ChanDistc (probe geometry only), and MaskPred+CCFDistc as the histology / atlas oracle upper bound. Across this family, each geometry prior improves frozen localization when it is available at training (MaskPred alone → ChanDistc → ManipDistc → CCFDistc oracle). That graded improvement is exactly why we see a single multi-prior localizer as realistic next work: the same model can use probe layout always, surgical insertion when logged, and atlas registration when histology exists, without requiring every lab to have every signal. Our released checkpoints already cover those metadata regimes; fusing them into one system that returns coordinates plus confidence is the natural next step.\n\nLonger term, we also want to bring brain-atlas structure across species into the same localizer, so that a model trained largely on mouse can make better use of primate or other non-mice atlases when those exist. That step depends on appropriately registered multi-lab data and shared coordinate conventions; we treat it as follow-on work rather than a claim of the present paper.\n\nThe below table is that comparison under a *matched* frozen transformer decoder Gaussian readout on the 75k checkpoints. Importantly, at this decoding stage we **do not** feed micro-manipulator coordinates into the head again, only the frozen LFP embeddings, so the rows fairly show what each pretraining objective learned (unlike our earlier Q4 insertion-aware table, where manip xyz is fused at readout).\n\n*Table 1: Frozen 75k transformer decoder Gaussian readout, 8 seeds, no manip at readout. RMSE in µm.*\n\n| Head | Loss | MaskPred | +ChanDistc | +ManipDistc | +CCFDistc |\n| --- | --- | ---: | ---: | ---: | ---: |\n| **RAW 3D-RMSE** | | | | | |\n| Linear | Gaussian | 2246.3±0.4 | 2160.2±2.6 | 2060.4±0.4 | 2039.1±0.4 |\n| MLP | Gaussian | 2275.2±6.4 | 2066.4±4.0 | 2043.6±4.6 | 2020.1±4.0 |\n| Transformer | Gaussian | 1904.4±36.6 | 1424.6±52.2 | 1335.1±37.3 | 1302.3±27.5 |\n| **Kabsch-fitted 3D-RMSE** | | | | | |\n| Linear | Gaussian | 1954.7±2.0 | 1769.1±5.2 | 1536.8±0.6 | 1520.4±0.4 |\n| MLP | Gaussian | 1867.7±9.8 | 1583.9±9.9 | 1492.9±13.0 | 1459.3±9.4 |\n| Transformer | Gaussian | 1861.1±37.0 | 1325.9±54.6 | 1276.2±29.5 | 1269.8±27.0 |\n\nThe above table is why we feature MaskPred+ManipDistc as the main model, it is the strongest histology-free pretraining and approaches the CCFDistc oracle. Thank you again for pushing us to write this framing down clearly."
+ },
+ "createdAt": "2026-08-03T23:10:32.989Z",
+ "modifiedAt": "2026-11-19T16:53:08.288Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=SY3Er0ZIxg",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/tkutjxbbw2.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/tkutjxbbw2.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "tKuTJxBBW2",
+ "replyTo": "QnQ0jjjxaC",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer exC2 (part 2/6)",
+ "comment": "### A2 --- Gaussian vs. MSE loss and linear vs. MLP head\nThank you for pointing this out. We report the requested ablation in\nthe table below on the IBL **75k** scale (8 seeds).\nWe compare three SSL objectives under a frozen backbone:\nMaskPred-only (the published lfp2vec baseline; linear head),\nMaskPred$+$ChanDistc (ours), and MaskPred$+$CCFDistc\n(histology-dependent oracle auxiliary).\nFor each arm we report RAW per-sample RMSE (primary), channel-pooled RMSE\n(inverse-variance $\\\\sigma$-pool for Gaussian; mean pool for MSE), and\nKabsch-fitted RMSE (secondary; rigid fit of known probe geometry onto\npredictions --- ground-truth CCF is *not* used in the fit).\nOn RAW, Gaussian and MSE are similar for the linear head.\nAn MLP helps relative to linear under both ChanDistc and CCFDistc.\nThe transformer decoder is substantially stronger than\nper-channel linear/MLP for both geometry-aware objectives.\nCCFDistc remains an upper bound because it requires atlas-registered CCF\ncoordinates during training, whereas ChanDistc uses only within-probe\nhardware geometry.\n\n**Table 2**: Ablation of localization head (linear / MLP / transformer), loss\n(Gaussian vs. MSE), and channel pooling on **75k** frozen SSL\nbackbones.\nBlocks: MaskPred-only (lfp2vec baseline; linear only),\nMaskPred$+$ChanDistc (ours),\nMaskPred$+$CCFDistc (histology-dependent oracle aux).\nMean $\\\\pm$ SD over 8 seeds; RMSE in µm. RAW is primary.\nKabsch = channel-pool then per-probe rigid geometry fit (no GT in fit).\n\n| SSL objective | Regime | Head | Loss function | Channel pooling | Raw 3D-RMSE (µm) | Channel-pooled 3D-RMSE (µm) | Kabsch-fitted 3D-RMSE (µm) |\n| --- | --- | --- | --- | --- | ---: | ---: | ---: |\n| MaskPred-only | Frozen SSL | Linear | Gaussian | inv-var $\\\\sigma$-pool | $2246.3 \\\\pm 0.4$ | $2115.5 \\\\pm 0.4$ | $1954.7 \\\\pm 2.0$ |\n| MaskPred-only | Frozen SSL | Linear | MSE | mean pool | $2232.8 \\\\pm 0.6$ | $2048.5 \\\\pm 0.7$ | $1843.0 \\\\pm 0.6$ |\n| MaskPred$+$ChanDistc | Frozen SSL | Linear | Gaussian | inv-var $\\\\sigma$-pool | $2160.2 \\\\pm 2.6$ | $1978.7 \\\\pm 3.7$ | $1769.1 \\\\pm 5.2$ |\n| MaskPred$+$ChanDistc | Frozen SSL | Linear | MSE | mean pool | $2170.1 \\\\pm 2.8$ | $1951.3 \\\\pm 5.0$ | $1724.4 \\\\pm 7.6$ |\n| MaskPred$+$ChanDistc | Frozen SSL | MLP | Gaussian | inv-var $\\\\sigma$-pool | $2066.4 \\\\pm 4.0$ | $1835.1 \\\\pm 6.6$ | $1583.9 \\\\pm 9.9$ |\n| MaskPred$+$ChanDistc | Frozen SSL | MLP | MSE | mean pool | $2133.9 \\\\pm 6.2$ | $1853.0 \\\\pm 6.7$ | $1587.3 \\\\pm 9.1$ |\n| MaskPred$+$ChanDistc | Frozen SSL | Transformer | Gaussian | inv-var $\\\\sigma$-pool | $1424.6 \\\\pm 52.2$ | $1343.9 \\\\pm 54.4$ | $1325.9 \\\\pm 54.6$ |\n| MaskPred$+$ChanDistc | Frozen SSL | Transformer | MSE | mean pool | $1346.7 \\\\pm 46.8$ | $1285.0 \\\\pm 42.8$ | $1269.5 \\\\pm 44.7$ |\n| MaskPred$+$CCFDistc | Frozen SSL | Linear | Gaussian | inv-var $\\\\sigma$-pool | $2039.1 \\\\pm 0.4$ | $1763.9 \\\\pm 0.2$ | $1520.4 \\\\pm 0.4$ |\n| MaskPred$+$CCFDistc | Frozen SSL | Linear | MSE | mean pool | $2079.3 \\\\pm 0.3$ | $1790.4 \\\\pm 0.3$ | $1541.5 \\\\pm 0.4$ |\n| MaskPred$+$CCFDistc | Frozen SSL | MLP | Gaussian | inv-var $\\\\sigma$-pool | $2020.1 \\\\pm 4.0$ | $1733.7 \\\\pm 6.5$ | $1459.3 \\\\pm 9.4$ |\n| MaskPred$+$CCFDistc | Frozen SSL | MLP | MSE | mean pool | $2106.6 \\\\pm 2.5$ | $1784.4 \\\\pm 2.0$ | $1515.3 \\\\pm 3.5$ |\n| MaskPred$+$CCFDistc | Frozen SSL | Transformer | Gaussian | inv-var $\\\\sigma$-pool | $1302.3 \\\\pm 27.5$ | $1281.0 \\\\pm 26.7$ | $1269.8 \\\\pm 27.0$ |\n| MaskPred$+$CCFDistc | Frozen SSL | Transformer | MSE | mean pool | $1319.8 \\\\pm 45.9$ | $1302.1 \\\\pm 41.4$ | $1293.6 \\\\pm 41.1$ |"
+ },
+ "createdAt": "2026-07-28T23:35:50.843Z",
+ "modifiedAt": "2026-11-19T16:53:08.888Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=tKuTJxBBW2",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/towkjngpdx.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/towkjngpdx.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "TOwKJNgPDx",
+ "replyTo": "QnQ0jjjxaC",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer exC2 (part 6/6)",
+ "comment": "### Minor comments (continued)\n- **Spectral feature baselines (kNN/band, kNN/PCA-PSD, Ridge/PSD).**\n These are classical LFP baselines we reimplemented for a fair comparison\n (band-power / Welch PSD features with kNN or ridge).\n We will cite the usual spectral-feature practice in intracranial decoding\n and put the exact feature recipe in the appendix.\n- **Appendix cross-references (e.g., Kabsch / Appendix D.3).**\n Agreed. As already clarified in Reviewer 2 Q1, Kabsch uses only on-probe\n geometry mapped to predicted xyz coordinates; ground truth is used only for\n RMSE evaluation. We have also added the RMSE scores if we used GT coordinates\n for Kabsch and it results in RMSE of 107.2 µm. We will rewrite\n Appendix D.3 and add clear pointers from the main text.\n- **Hyperparameter search.**\n The hyperparameter search is done using the Ray Tune library with HEBO\n (see table below).\n We used Optuna in earlier exploratory runs; the reported configurations\n were selected with HEBO.\n\n **Table 4**: Hyperparameter sweep (Ray Tune + HEBO).\n Selected values are those used in the reported MaskPred$+$ChanDistc runs.\n † Warmup was increased for larger-scale training.\n\n | Hyperparameter | Search range | Selected value |\n | --- | --- | --- |\n | learning rate | $5\\\\times10^{-5}$ -- $1\\\\times10^{-3}$ | $1.02\\\\times10^{-4}$ |\n | weight decay | $1\\\\times10^{-4}$ -- $0.1$ | $0.080$ |\n | hidden dropout | $0.0$ -- $0.3$ | $0.097$ |\n | attention dropout | $0.0$ -- $0.3$ | $0.084$ |\n | final dropout | $0.0$ -- $0.3$ | $0.0$ |\n | mask probability | $0.05$ -- $0.50$ | $0.079$ |\n | mask span length | $5$ -- $60$ | $5$ |\n | unfrozen top-$k$ layers | {0,2,4,6,8,12} | $12$ |\n | warmup steps | {50,100,200,400} | $400 \\\\rightarrow 1200$ † |\n | warmup start factor | $0.001$ -- $0.1$ | $0.01 \\\\rightarrow 0.001$ † |\n | ChanDistc kernel width $\\\\sigma$ | {100,200,300,500,750,1000} µm | 500 µm |\n\n We have removed any leftover Optuna wording.\n- **Audio encoders are single-channel.**\n Yes. wav2vec 2.0 / Whisper / Data2Vec are used as single-channel encoders on\n each LFP channel independently.\n We will say this clearly for readers who are less familiar with audio models.\n- **Related work (NeuPrint, NuCLR, …).**\n Thank you for the pointers.\n We will add NeuPrint and NuCLR to the related work and briefly explain how\n our LFP-channel localization setting differs from neuron-/population SSL for\n spike region identity.\n- **Figure resolution (e.g., Fig. 3).**\n Agreed (also noted by Reviewer 1).\n We will replace low-resolution figures with higher-resolution versions and\n fix labels/colors in the revision.\n\nWe have incorporated additional experimental results to directly address all raised concerns. These additions respond point-by-point to the questions above. We are grateful for the reviewer's thoughtful comments and the improvements they prompted. We welcome any further feedback that would help us continue improving the quality of the paper.\n\n**References**\n\n[lfp2vec] He, T., Patel, M., Li, C., Maslarova, A., Vöröslakos, M., Ramanathan, N., Hung, W.-L., Buzsáki, G., & Varol, E. (2026). Self supervised learning for in vivo localization of microelectrode arrays using raw local field potential. Advances in Neural Information Processing Systems, 38, 124297-124320.\n\n[angotzi2025multishank] Angotzi, G. N., Vöröslakos, M., Perentos, N., Ribeiro, J. F., Vincenzi, M., Boi, F., Lecomte, A., Orban, G., Genewsky, A., Schwesig, G., Aykan, D., Buzsáki, G., Sirota, A., & Berdondini, L. (2025). Multi-shank 1024 channels active SiNAPS probe for large multi-regional topographical electrophysiological mapping of neural dynamics. *Advanced Science*, 12(16), e2416239. https://doi.org/10.1002/advs.202416239"
+ },
+ "createdAt": "2026-07-28T23:43:29.047Z",
+ "modifiedAt": "2026-11-19T16:53:08.558Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=TOwKJNgPDx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/uncmsy3yux.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/uncmsy3yux.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "uncmSy3YuX",
+ "replyTo": "gA3rJyliMS",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer erKH (part 5/6)",
+ "comment": "### Q5\n\n**Hyperparameters:** We utilized the Ray Tune framework across all experiments, specifically employing its built-in HEBOSearch algorithm for mid-training. The mention of Optuna in the text was a leftover artifact from older preliminary runs. We will remove all Optuna references (Lines 527--528) and list the tuned hyperparameters explicitly in the text, including learning rate, weight decay, mask probability, mask length, dropouts, unfrozen top-$k$ layers, and ChanDistc sigma.\n\nPlease refer to Table 6 for details on the hyperparameter sweep. Two hyperparameters, warmup steps and warmup start factor, were scaled with dataset size rather than held at their searched values, so that the warmup fraction remains approximately constant as the number of steps per epoch increases with scale.\n\nFor the $\\\\sigma$ hyperparameter, rather than tuning the geometry kernel width by proxy, we sweep it directly on the downstream task across a $10\\\\times$ range of $100$--$1000~\\\\mu$m.\n\n**Table 6.** Hyperparameter sweep.\n\n| **Hyperparameter** | **Search range** | **Selected value** |\n| --- | --- | --- |\n| Learning rate | $5\\\\times10^{-5}$--$1\\\\times10^{-3}$ | $1.02\\\\times10^{-4}$ |\n| Weight decay | $1\\\\times10^{-4}$--$0.1$ | $0.080$ |\n| Hidden dropout | $0.0$--$0.3$ | $0.097$ |\n| Attention dropout | $0.0$--$0.3$ | $0.084$ |\n| Final dropout | $0.0$--$0.3$ | $0.0$ |\n| Mask probability | $0.05$--$0.50$ | $0.079$ |\n| Mask span length | $5$--$60$ | $5$ |\n| Unfrozen top-$k$ layers | $\\\\{0,2,4,6,8,12\\\\}$ | $12$ |\n| Warmup steps | $\\\\{50,100,200,400\\\\}$ | $400\\\\rightarrow1200^{\\\\dagger}$ |\n| Warmup start factor | $0.001$--$0.1$ | $0.01\\\\rightarrow0.001^{\\\\dagger}$ |\n| Kernel width $\\\\sigma$ | $\\\\{100,200,300,500,750,1000\\\\}~\\\\mu$m | $500~\\\\mu$m |\n\n**Region Counts:** The anatomical region topology is completely uniform across our work. The differing region counts merely reflect the physical coverage of the specific datasets. The Allen dataset has a limited number of insertions covering 116, not 115, unique regions, whereas the IBL Brain Wide Map provides comprehensive coverage spanning 309 regions. We update the text (Line 67) to ensure these counts are explicitly tied to their respective datasets.\n\n**Explicit Limitations and Aggregate Errors:** We candidly agree with your assessment regarding the need to contextualize our error margins. We will introduce a dedicated Limitations section acknowledging that an aggregate error of 1.6 mm is highly significant for a mouse brain and that the method is not yet ready to serve as a histology-free localization tool.\n\nWe will reframe the $202~\\\\mu$m best-case result strictly as a proof of concept demonstrating what spatial priors can achieve on highly favorable trajectories. We position this paper as establishing a foundational baseline for spatial representation learning that points toward a clear scaling path.\n\nUsing scaled-up models paired with a transformer decoder, we are currently observing average test errors in the 0.8 mm range when using surgical insertion information and the 1.2 mm range for the 1M model. We have also found that increasing the temporal window size from 3 seconds to 5 and 10 seconds progressively lowers the RMSE; see Reviewer exC2, A1."
+ },
+ "createdAt": "2026-07-28T23:27:33.076Z",
+ "modifiedAt": "2026-11-19T16:53:08.864Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=uncmSy3YuX",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/whwyhj147e.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/whwyhj147e.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Whwyhj147E",
+ "replyTo": "QnQ0jjjxaC",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "## Author Follow-up Response — Reviewer exC2 (part 1/2)",
+ "comment": "Thank you for the careful follow-up and for the positive assessment of the window, head/loss, zero-shot, and runtime clarifications. We answer the remaining points below and will update the revision accordingly.\n\n### A1 — Inference time axis\n\nThank you for this suggestion, you are right that pretraining is a one-time investment, so inference timing matters more. Larger windows also increase per-chunk inference time. Below is the same table with an Infer column (batch size=1, 1 CPU worker).\n\n*Table: 25k MaskPred+ChanDistc window ablation on IBL Test (frozen linear). Infer: H100, batch_size=1, num_workers=1 (wall median). RMSE in µm.*\n\n| Window | Raw Gauss | Kabsch Gauss | Raw MSE | Kabsch MSE | Min/epoch | Infer ms |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| 1 s | 2381.2 | 2067.5 | 2375.1 | 2020.2 | 1.9 | 4.3 |\n| 2 s | 2280.0 | 1939.6 | 2290.2 | 1901.3 | 5.1 | 4.6 |\n| 3 s | 2271.8 | 1909.4 | 2272.6 | 1862.1 | 6.5 | 4.7 |\n| 5 s | 2153.4 | 1776.3 | 2147.9 | 1751.1 | 9.4 | 5.1 |\n| 10 s | 2093.5 | 1734.6 | 2055.6 | 1647.8 | 18.9 | 6.9 |\n\nInference scales with window size, but not steeply, even 10 s remains real-time.\n\n### A2 — Channel-pooled RMSE, Transformer Channel Mixing And Best Decoder Recommendation\n\n**(1) Channel-pooled RMSE.**\nSorry for the confusion, this is not a new metric. It is the middle column of the head/loss ablation table we already reported (Raw / Channel-pooled / Kabsch-fitted). The model predicts XYZ for every 3 s chunk; for a fixed (probe, channel) we average those predictions over time (mean for MSE, uncertainty-weighted for Gaussian) to get one XYZ per channel. That averaged error is “channel-pooled.” Kabsch comes after, if used: a rigid fit of known probe geometry onto those channel predictions (no GT in the fit). So Raw = per-chunk (primary); Channel-pooled = after time average; Kabsch = after the rigid fit.\n\n**(2) Does the transformer mix channels? Is time pooled first?**\nYes, the transformer decoder sees channels as a depth-ordered sequence and attends across them. During training we feed one probe at a time (channels sorted by on-probe depth), so self-attention mixes channels *within that probe only*, not across probes. Time is still pooled first: within each 3 s LFP chunk, the frozen audio backbone mean-pools over time to one embedding per channel-chunk, then the transformer sees the channel sequence. (Within-chunk temporal pooling before the head, not the later channel-pooled / Kabsch evaluation steps.)\n\n**(3) Parameter count / capacity vs. architecture.**\nA 1-hidden MLP (768→256) is 198k params; our strongest transformer (4 blocks, d=256, h=8) is 2.38M. Extra capacity alone does not explain the gap: a larger channel-mixing MLP without attention (3.44M) and deeper per-channel MLPs still do worse than the transformer on held-out test. Below: mean±std over seeds (frozen 75k MaskPred+ChanDistc, Gaussian), same Raw / Channel-pooled / Kabsch columns as Table 2.\n\n*Table: Head capacity / mixing ablation on the held-out IBL test set (mean±std over seeds). RMSE in µm. Columns: Raw, Channel-pooled, Kabsch-fitted (as in Table 2). Gaussian loss. blk=blocks, d=width, h=heads, ff=feed-forward. **final**=heads used elsewhere.*\n\n| Head | Params | Raw 3D-RMSE (µm) | Channel-pooled 3D-RMSE (µm) | Kabsch-fitted 3D-RMSE (µm) |\n| --- | ---: | ---: | ---: | ---: |\n| **MLP 768→256 (1 hidden; final)** | 198,406 | 2064.0±3.7 | 1833.9±7.3 | 1580.4±8.6 |\n| MLP 768→256→128 (2 hidden) | 230,534 | 2080.7±6.7 | 1835.0±7.5 | 1546.6±6.6 |\n| MLP 768→256→128→64 (3 hidden) | 238,406 | 2133.7±16.5 | 1856.8±17.2 | 1511.8±14.2 |\n| MLP channel-mixer, no attn | 3,436,559 | 1579.7±22.3 | 1550.8±27.6 | 1537.0±28.7 |\n| Transformer 1 blk / d64 / h4 / ff128 | 87,951 | 1530.8±38.2 | 1457.6±39.4 | 1439.5±41.1 |\n| Transformer 1 blk / d96 / h4 / ff192 | 159,567 | 1524.5±65.4 | 1448.4±61.0 | 1430.6±61.6 |\n| Transformer 1 blk / d128 / h8 / ff256 | 249,615 | 1514.2±54.9 | 1424.5±36.8 | 1409.0±36.6 |\n| Transformer 1 blk / d192 / h8 / ff384 | 485,007 | 1476.4±50.8 | 1385.4±40.6 | 1368.1±40.8 |\n| Transformer 1 blk / d256 / h8 / ff512 | 794,127 | 1506.3±73.0 | 1402.9±56.7 | 1382.9±57.2 |\n| Transformer 2 blk / d256 / h8 / ff512 | 1,321,231 | 1424.8±53.6 | 1349.9±53.8 | 1332.8±53.7 |\n| **Transformer 4 blk / d256 / h8 / ff512 (final)** | 2,375,439 | 1429.8±24.5 | 1345.3±35.4 | 1322.2±38.4 |\n\n*(Continued in part 2/2.)*"
+ },
+ "createdAt": "2026-07-31T08:53:04.395Z",
+ "modifiedAt": "2026-11-19T16:53:08.428Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=Whwyhj147E",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/wykdtigw06.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/wykdtigw06.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "wYkdtIgW06",
+ "replyTo": "TOwKJNgPDx",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer exC2",
+ "content": {
+ "comment": "I thank the authors for their detailed response, which addresses all of the points raised in my review. \n\n\nI also appreciate the points raised by Reviewers uaNP and erKH, which substantially improved the clarity of the method and its evaluation (MaskPred is lfp2vec, CCFDistc is an Oracle, Kabsch Refinement details, animal split confirmation), as well as the additional experiment requested by Reviewer uaNP on incorporating insertion trajectory information. That experiment both improves performance and aligns the setup with the data actually available before histology, which pushes the paper closer to its intended application: probe localization at implantation time, while data is being recorded, rather than retrospectively via histology.\n\n\n## A1. Choice of the 3-second window and window-size ablation\nThank you for the window-size study, which gives an informative trade-off between performance and training time.\n\n\nI would suggest adding inference time as a second axis of this trade-off, since longer windows may increase inference cost, potentially at a different scale than training cost.\nTraining time is a real cost dimension, but pretraining is a one-time expense that can be incurred well in advance of the experiment, whereas the downstream application will likely be constrained by fast inference at the moment probe localization is needed.\n\n## A2. Gaussian vs. MSE loss and linear vs. MLP head\nThank you for the head and loss ablation. \n\n\nI particularly appreciate the additional exploration of the transformer head, which was not originally requested and is a valuable addition.\n\n\nThe finding that Gaussian and MSE are broadly comparable with no clear winner, while the transformer decoder clearly outperforms the MLP and linear heads, is useful. \n\n\nA few remaining questions:\n1. I am not certain what channel-pooled RMSE corresponds to. Could you clarify the metric? Is it a new metric introduced here, or one already used in the paper or in the responses to other reviewers?\n2. Does the transformer head perform channel mixing, i.e. does it attend across channels? Could you also confirm whether the temporal dimension is still pooled before entering this head?\n3. What is the parameter count of the transformer head, and is it matched to that of the MLP? This detail would clarify whether the improvement comes from the architecture (channel mixing) or simply from additional capacity.\n4. Do the authors consider the transformer head the recommended configuration going forward? If so, would this variant, combined with the insertion trajectory information from the Reviewer uaNP, reach state-of-the-art performance? If that is the case, I would encourage promoting it from the ablation into the main results.\n\n## A3.1. Region lookup vs. classifier head\nClear, thank you. This resolves my question.\n\n\n## A3.2. Zero-shot cross-species transfer\nThank you for clarifying the zero-shot protocol.\n\nMy understanding is that the model performs a forward pass over all channels from the probes in both the train and evaluation sets. For a given evaluation channel, the k nearest neighbours in the train set are retrieved by cosine similarity, and the brain region is assigned by majority vote over their labels. \n\nCould you confirm or correct this description? Could you also report the value of k, and whether it is selected according to a specific protocol (for example on a validation split)?\n\nA clear breakdown of this protocol in the manuscript would be a useful addition.\n\n## A3.3. Difference between CCFDistc and ChanDistc\nClear, thank you. \n\n## A4. Runtime breakdown and real-time feasibility\nThank you for the end-to-end runtime breakdown, which supports the claim of real-time feasibility, even if further engineering would be needed to build a complete system (for example, streaming data transfer from the probe to the GPU).\n\nIt is also encouraging that the component to optimize is the audio backbone, should real-time constraints be pursued in future work. For follow-up work studying this aspect, reporting FLOPs alongside wall-clock timings would give a measure that is less contingent on the specific GPU used.\n\nThe point about accelerating inference through batching across chunks and probes, and multi-GPU parallelism are very relevant. Could you confirm whether the reported timings were obtained with a batch size of 1 and a single CPU worker for data loading?\n\n## Minor comments\nAll addressed, thank you."
+ },
+ "createdAt": "2026-07-30T05:21:53.902Z",
+ "modifiedAt": "2026-11-19T16:53:08.433Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=wYkdtIgW06",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/wzs4synggz.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/wzs4synggz.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "wZs4SyngGZ",
+ "replyTo": "x4dzp5ILBB",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the Area Chair for the careful and constructive Meta Review, and for\nclearly laying out what still needed clarification. We agree that the evaluation\nand writing had to be tightened, and we have used the discussion period to\nanswer each of the points below-both in this note and in the individual\nreviewer replies, where the tables and extra experiments live.\n\n1. **SSL baseline**: Our MaskPred model *is* the published lfp2vec [1] method\nfrom last year, not a weaker masked-only stand-in. We will say\nthis explicitly in the revised paper so the naming no longer causes confusion,\nand we put a direct comparison of MaskPred, our method, and a stronger\nhistology-based variant in the Q1 answer for reviewer **uaNP**.\n\n2. **train/test leakage**: the train/test split is by animal(mice), so the same mouse never appears in\nboth training and testing. That choice is intentional, a tool that only works\non animals it has already seen is much less useful in practice. The one\nwithin-subject check we report is on NeuroNexus [2]. We will make this clearer in\nthe Datasets section of the main paper (line 62).\n\n3. **Kabsch fitting**: this step does not peek at ground-truth brain coordinates. It only\nuses the known probe geometry template to clean up the model's predictions,\nand it does not require histology. We have clarified this in the Appendix D.3 in the revise paper and give details on the Kabsch fitting as response to reviewer **exC2**.\nWe have rewritten Appendix D.3 so the correct description is the one that remains.\n\n4. **zero-shot cross-species transfer**: For macaques, we don't do coordinate regression since we are also aware that the stereotaxic coordinates of mice might not translate to monkeys. Instead, we do straight brain region classification (like in lfp2vec [lfp2vec] paper just directly predict the brain regions. We explained this in more detail in A3.2 for reviewer **exC2**. Also have updated Fig. 4 caption to reflect this.\n\n5. **hyperparameters and robustness**: how we chose hyperparameters is in the Q5 answer for\nreviewer **erKH**. We also added extra checks on input window length, loss\nheads, and readout models. Longer windows help a little but take longer to\ntrain; 3-5 seconds of context feels like a sensible middle ground. The full\ndetails are in the reviewer **exC2** responses.\n\nFinally, on clarity, several reviewers pointed out places where the text,\nfigures, and captions did not line up, and where the data description was easy\nto misread. We resolved those contradictions in the main paper,\nand also explained the corrections in detail in the per-reviewer replies.\n\nWe once again thank everyone for their insightful critiques that helped us improve the clarity of the paper.\n\n**References**\n\n[1] He, T., Patel, M., Li, C., Maslarova, A., Vöröslakos, M., Ramanathan, N., Hung, W.-L., Buzsáki, G., & Varol, E. (2026). Self supervised learning for in vivo localization of microelectrode arrays using raw local field potential. Advances in Neural Information Processing Systems, 38, 124297-124320.\n\n[2] Angotzi, G. N., Vöröslakos, M., Perentos, N., Ribeiro, J. F., Vincenzi, M., Boi, F., Lecomte, A., Orban, G., Genewsky, A., Schwesig, G., Aykan, D., Buzsáki, G., Sirota, A., & Berdondini, L. (2025). Multi-shank 1024 channels active SiNAPS probe for large multi-regional topographical electrophysiological mapping of neural dynamics. *Advanced Science*, 12(16), e2416239. https://doi.org/10.1002/advs.202416239"
+ },
+ "createdAt": "2026-07-28T23:38:10.675Z",
+ "modifiedAt": "2026-11-19T16:53:08.685Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=wZs4SyngGZ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/heiyaxz4a8/notes/x4dzp5ilbb.json modified

+++ b/reviews/openreview/heiyaxz4a8/notes/x4dzp5ilbb.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair U5dy",
"content": {
- "metareview": "Initial meta-review: Currently your paper needs additional clarification and evaluation. \n\nThe authors noted the significance and timeliness of the problem and proposed method, and some reviewers noted the novelty of the approach.\nHowever there were multiple concerns about the evaluation that need to be clarified during the discussion period (please see the reviews for specific details) and additional experiments run if the original indeed suffer from the issues identified by the reviewers to both satisfy concerns regarding quality of the results and reproducibility:\n* The SSL baseline and the objective used in training it (i.e. comparison to LFP2vec is required if this is not the baseline in the paper), \n* the train-test split and whether there is leakage of of same session / animal across train and test, \n* the role of the ground-truth coordinate model / Kabsch alignment, \n* clarification regarding zero-shot cross species coordinate transfer, \n* ablation and robustness to hyperparam choices. \n\nReviewers also noted multiple issues with clarity of the writing, specifically contradictions between the text, the figures and the captions, and descriptions of the properties of the data. Please clarify during the discussion period how you would modify the text (i.e. which description in the paper is the correct one)."
+ "metareview": "Initial meta-review: Currently your paper needs additional clarification and evaluation. \n\nThe authors noted the significance and timeliness of the problem and proposed method, and some reviewers noted the novelty of the approach.\nHowever there were multiple concerns about the evaluation that need to be clarified during the discussion period (please see the reviews for specific details) and additional experiments run if the original indeed suffer from the issues identified by the reviewers to both satisfy concerns regarding quality of the results and reproducibility:\n* The SSL baseline and the objective used in training it (i.e. comparison to LFP2vec is required if this is not the baseline in the paper), \n* the train-test split and whether there is leakage of of same session / animal across train and test, \n* the role of the ground-truth coordinate model / Kabsch alignment, \n* clarification regarding zero-shot cross species coordinate transfer, \n* ablation and robustness to hyperparam choices. \n\nReviewers also noted multiple issues with clarity of the writing, specifically contradictions between the text, the figures and the captions, and descriptions of the properties of the data. Please clarify during the discussion period how you would modify the text (i.e. which description in the paper is the correct one).",
+ "final_justification": "I have read the reviewer and author discussions, and discussed the paper with the reviewers after the rebuttal period and recommend acceptance. \nThe rebuttal resolved the main concerns of the reviewers (e.g., clarifying the baseline method, train-test splits, clarifying Kabsch fitting does not use ground truth, etc.), including extensive new experimental results and comparisons, and the reviewers find the paper a valuable contribution for the community. \n\nIn the final camera-ready the author noted they intend to make MaskPred+ManipDistc the main model, beyond the original paper's model (ChanDistc) and should indeed include the results combining the insertion trajectory with transformer head.\nPlease add the promised explanation of novelty with respect to related work, as well as future extensions. \nDuring the rebuttal there were also clarifications that narrowed the claims of the paper: the method is not yet ready to serve as a histology-free localization tool, and clarifying what is meant by zero-shot cross-species transfer. The authors should update the paper accordingly.\nI agree with reviewer erKH that the main results should include both Kabsch geometric metrics and standard per-channel metrics (e.g., raw RMSE), and the authors should clarify performance with respect to both. \nThe AC strongly encourages the authors to incorporate all reviewer feedback on clarity as discussed during the rebuttal period, to improve the final version of the manuscript. \n\n\nA problematic reference: 'Deep brain stimulation-induced local evoked potentials outperform spectral features in spatial and clinical STN mapping') was automatically identified: the author list is incorrect and is obviously hallucinated. Please correct the reference in the camera-ready and be more careful in future submissions."
},
"createdAt": "2026-07-22T06:58:06.785Z",
- "modifiedAt": "2026-11-18T15:25:06.104Z",
+ "modifiedAt": "2026-11-19T05:03:14.539Z",
"url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=x4dzp5ILBB",
"license": "CC-BY-4.0"
}

reviews/openreview/heiyaxz4a8/notes/yqptuusilr.json added

+++ b/reviews/openreview/heiyaxz4a8/notes/yqptuusilr.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "YqPTUUsILr",
+ "replyTo": "tKuTJxBBW2",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal by Authors to Reviewer exC2 (part 3/6)",
+ "comment": "### A3.1 --- Region lookup vs. classifier head\nIn earlier iterations of our methodology, we used a regression head followed by a discrete classifier to predict brain region labels\ndirectly. The finalized approach in the manuscript predicts continuous XYZ coordinates only; these are mapped onto the Allen CCF\nannotation volume for anatomical region lookup, with no dedicated classification head. Figure 4 (NeuroNexus / macaque) is a separate\nregion-classification evaluation from frozen embeddings (see A3.2), not that XYZ→CCF lookup pipeline. We have updated Appendix\nlines 511--513 in the revised paper so this distinction is explicit.\n\n### A3.2 --- Zero-shot cross-species transfer\nRegarding the zero-shot transfer results in Figure 4 for NeuroNexus and macaque, we do not regress coordinates. We classify anatomical\nlabels from frozen embeddings of our 75k MaskPred$+$ChanDistc backbone. \"Zero-shot\" means zero trainable parameters: cosine $k$-NN\non those embeddings (build a labeled reference bank; assign each test sample the majority label among its nearest neighbors). This\navoids cross-species atlas alignment. The other Figure 4 bars are also region classification on the same targets, but with trainable\nreadouts (frozen linear probe / full fine-tune) or classical supervised baselines (e.g. HistGBM, spectral features) under the same\nsplits.\n\n### A3.3 --- Difference between CCFDistc and ChanDistc\n\nWe appreciate the opportunity to clarify this distinction and will ensure the manuscript is updated accordingly. The ChanDistc objective utilizes strictly the physical probe geometry for contrastive learning. For NP1.0 probes, we know the exact physical distances between channels along the shank, but we do not require their registered atlas locations. Conversely, the CCFDistc objective relies on exact CCF coordinates in the registered atlas space, which are only obtainable following histological verification.\n\nFurthermore, regarding multiple probe configurations, ChanDistc operates entirely within probe. It uses structured batches from the same probe, and distance metrics are defined solely by the hardware layout. In contrast, CCFDistc operates globally across probes using shuffled batches, where distances are calculated in the 3D Allen CCF space, allowing it to connect spatially proximate channels that belong to entirely different insertions. While both utilize a similar soft distance contrastive formulation, their batching structures and distance definitions are fundamentally distinct. Because our primary goal is to develop a histology free localization tool, CCFDistc is not intended for deployment. Instead, it serves purely as an oracle performance ceiling to demonstrate the upper bounds of spatial representation learning, as it strictly requires atlas registered CCF coordinates during training, whereas ChanDistc does not."
+ },
+ "createdAt": "2026-07-28T23:36:40.528Z",
+ "modifiedAt": "2026-11-19T16:53:08.561Z",
+ "url": "https://openreview.net/forum?id=hEiyAXz4A8&noteId=YqPTUUsILr",
+ "license": "CC-BY-4.0"
+}