GlycoGen: Glycan Structure Prediction with Crystallizing Flows
Update NeurIPS 2026 submission hhpivLTcN3: 8 notes
@openreview[bot] · 2026-11-24 15:54 UTC · 801a6ccfcbd1 ·
reviews/openreview/hhpivltcn3/notes/4bmsmhxhme.json added
+++ b/reviews/openreview/hhpivltcn3/notes/4bmsmhxhme.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "4bmSMHxHme",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Anonymized code, datasets, and experiments reproduction pipeline",+ "comment": "Dear Area Chair and Reviewers,\n\nPlease find our anonymized code, datasets, and experiments reproduction pipeline at:\n**https://anonymous.4open.science/r/GlycoGen-464D/**\n\nReviewers can reproduce every experiment in the paper (dataset build, training runs, evaluation sweeps) from the code alone:\n\n- `data_utils/`: scripts to rebuild the leak-free dataset split from the raw CandyCrunch v2 dataset (Urban et al. 2024).\n- `glycogen/dfm/`: GlycoGen-DFM (50M) training + Crystallizing Flows NFE sweep.\n- `glycogen/mdlm/`: GlycoGen-MDLM (50M) training + Crystallizing Flows NFE sweep.\n- `baselines/ar_seq2seq/`: matched-capacity AR control (identical architecture to DFM/MDLM, AR training objective).\n- `baselines/glycobart/`: GlycoBART (207M, previous SOTA) reproduction on our leak-free split with beam sweep.\n- READMEs with exact CLI commands for each experiment, including headers for HF Jobs reproducibility.\n\nThe release is anonymized. Trained checkpoints will be released on Hugging Face at camera-ready."+ },+ "createdAt": "2026-08-02T23:58:27.080Z",+ "modifiedAt": "2026-11-19T16:52:46.862Z",+ "url": "https://openreview.net/forum?id=hhpivLTcN3¬eId=4bmSMHxHme",+ "license": "CC-BY-4.0"+}
reviews/openreview/hhpivltcn3/notes/gl1sl1eaa1.json added
+++ b/reviews/openreview/hhpivltcn3/notes/gl1sl1eaa1.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "gl1SL1eAA1",+ "replyTo": "kll79OvYDt",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer QXH1",+ "comment": "We thank you for the careful review and specific questions. First, two clarifications upfront:\n\n- **Anonymized code is now posted** as a separate Official Comment (per NeurIPS policy).\n- **CandyCrunch v2 is not single-instrument.** The full dataset spans four instrument types: linear ion trap (51.6%), Orbitrap (22.7%), Bruker Amazon (15.5%), other (10.2%). GlycoGen K=1 scores 88.3% / 93.0% / 92.9% / 88.9% on each, respectively. We were mistaken and retract this limitation.\n\nWe ran additional experiments to answer each of your four questions in order. All supplemental tables are reported in our **Supplemental data** comment on the submission (S1–S3).\n\n \n## **Q1. Real-time motivation.** \nYou correctly observed the paper argues our improved inference speeds unlock real-time inline annotation, without establishing whether it is a current experimental bottleneck. Two points:\n\n1. **Inference is a bottleneck for offline batched annotation too.** The other pipeline stages (peak processing, preprocessing, IUPAC parsing) are negligible (0.1–1 ms/spec combined), and are dominated by fragment identification (neural forward pass or database search). This has limited the appeal of neural approaches to date: to batch-process a 10-hour LC-MS/MS acquisition (e.g., overnight auto-sampler queue, 5M spectra) on a H200, **GlycoBART would take 5 days** at their beam=32 SOTA configuration. GlycoGen only takes 4 minutes to 1 hour (K=1 to 32) and is +9–13pp more accurate across the range.\n2. **Speed is a hard limit on real-time annotation**, though we do not claim it is the only one. Recent LC-MS/MS instruments produce a spectrum every 5–10 ms (100–200 Hz). Data-Dependent Acquisition (DDA), which uses on-the-fly results to adjust the next acquisition parameters, requires annotations to fit that time window. The field has developed real-time fragment database search methods (see e.g. Schweppe et al. 2020 for proteomics; Armony et al. 2023 for glycopeptides) but they lack the accuracy of neural systems. Rapid inference enables better structure prediction in DDA workflows and novel experimental capabilities. \n\nCamera-ready will add an explanation of these motivations.\n\n \n\n## **Q2. End-to-end unbatched latency** \nYou asked for strict single-spectrum latency including overhead. \n\nWe timed the full pipeline (peak parsing → 2048-bin featurization → GPU encoder + decoder → sampling → IUPAC detokenization) on a H200 for single spectra:\n\n| Config | Avg NFE | Unbatched ms/spec | Top-1 |\n| --- | --- | --- | --- |\n| GlycoGen-DFM K=1 | 1 | 8.6 ± 0.3 | 90.2% |\n| GlycoGen-DFM-CF K=32 | 17 | 109 ± 10 | **92.7%** |\n| GlycoBART beam=1 | 36 | 183 ± 99 | 81.2% |\n| GlycoBART beam=32 (their SOTA config) | 1,157 | 256 ± 120 | 79.1% |\n\nGlycoGen K=1 is 21× faster than GlycoBART beam=1 with +9pp higher accuracy, and GlycoGen K=32 CF is 2.3× faster than GlycoBART's beam=32 SOTA config with +13.6pp higher accuracy. \n\nCamera-ready will report unbatched end-to-end latency alongside batched throughput. \n\n \n\n## **Q3. Paper readability for non-specialists**\nYou flagged the paper is difficult for readers unfamiliar with glycomics, with inadequate treatment of two key distinctions: \n* (a) *IUPAC strings vs glycan graphs*: every glycan has one underlying graph but multiple valid text spellings; our training loss is character-level, with no graph-level supervision. \n* (b) *Per-spectrum vs sample-level*: GlycoBART's 0.891 SOTA pipeline aggregates across a sample, and snaps predictions to the nearest structure in a database. GlycoGen predicts one structure per single spectrum with no lookup.\n\nFor the camera-ready version, we commit to adding:\n* a half-page technical primer for background on glycan basics and these two concepts\n* a new figure presenting a schematic of the full data pipeline\n* a failure-mode analysis in appendix. \n\nWe will stay within page limit by moving section 4.3 (and possibly algorithm details) to appendix.\n\n \n\n## **Q4. Experimental validation.** \nYou noted the main results were single-seed on a single split. We ran 3-seed retrains for every model, and report a full mean±std sweep and splits by data novelty and instrument (see Supplemental data comment). \n\n**All headline claims survive seed variance.** GlycoGen-DFM produces a result in just one forward pass at 90.19% ± 0.04pp accuracy. With Crystallizing Flows at K=8 (5 effective NFE), it reaches 92.51% ± 0.06pp, which is +2pp above AR at 262 NFE and +14pp above GlycoBART at 288 NFE. Crystallizing Flows improves on the default CTMC sampler by +1.82pp (DFM) / +1.91pp (MDLM) at K=64 (both outside experimental variance). MDLM tracks DFM within 0.5pp across K, so the sampler transfers across training objectives.\n\n \n\nWe hope these results answer your questions, and support raising your overall rating."+ },+ "createdAt": "2026-08-03T17:31:31.557Z",+ "modifiedAt": "2026-11-19T16:52:46.859Z",+ "url": "https://openreview.net/forum?id=hhpivLTcN3¬eId=gl1SL1eAA1",+ "license": "CC-BY-4.0"+}
reviews/openreview/hhpivltcn3/notes/jo6xamar9l.json added
+++ b/reviews/openreview/hhpivltcn3/notes/jo6xamar9l.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Jo6XaMar9l",+ "replyTo": "mx5pzLnOBn",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Area Chair ckkD",+ "comment": "Thank you for the meta-review and for recommending borderline accept contingent on the four conditions you listed. We ran new experiments against every point you and the reviewers raised.\n\nTwo updates first:\n\n- **Anonymized code** is now posted as a separate Official Comment.\n- **Full evidence tables** are in our **Supplemental data** comment (S1–S3).\n\n \n## **1. Narrowing headline claims**\nYou singled out strict Pareto dominance and _de novo_ generalization. We narrow both to a more precise scope:\n\n1. **We focus Pareto dominance claims to the low-NFE regime.** Crystallizing Flows dominates every alternative sampler at low NFE (5–17 passes); at high NFE (≥33), a MaskGIT-style greedy-confidence baseline matches within the noise floor. Camera-ready will scope the claim to \"low-NFE Pareto dominance, high-NFE tie within noise\".\n\n2. **We withdraw the _de novo_ claim.** The submitted title conflated two meanings of \"_de novo_\": in glycomics, predicting structure from the spectrum with no reference database at inference time, which GlycoGen does; in ML, generalizing to unseen structural classes, which GlycoGen does not (see item 3). To avoid overclaiming, we propose to change the title to **\"GlycoGen: Glycan Structure Prediction with Crystallizing Flows\"**.\n\n \n## **2. Multi-seed reporting**\nEvery model retrained on 3 seeds (S1). **All headline claims survive experimental variance**. The **+11.6pp gain over GlycoBART** decomposes into three levers: \n* architecture (46M vs 207M) -> **+9.5 ± 0.3pp**\n* training objective (DFM/MDLM vs AR, matched arch) -> **+2.1 ± 0.1pp**\n* sampler (CF vs CTMC, K=64) -> **+1.82 ± 0.08pp DFM / +1.91 ± 0.02pp MDLM**, strongly outside experimental error.\n\n \n## **3. Structure-level generalization**\n\nWe split the test set three ways by exact graph comparison (S2), since filenames alone cannot certify novelty (94.6% of shared test structures appear in ≥2 training runs). **Two findings:**\n\n**1. No generalization to unseen structural classes.** On test spectra whose structure is genuinely novel and unseen in training (n=505), all three models score near zero with overlapping CIs. This reflects a limitation of the dataset (only ~3,590 unique structures across ~500K spectra), not of any specific model: neither GlycoGen nor GlycoBART generalizes to novel glycan graphs. We make this explicit in Limitations.\n\n**2. Graph-isomorphism generalization: GlycoGen learns the glycan graphs of unseen strings, and strictly beats GlycoBART SOTA by 4.4×.** On glycan strings unseen in training but with a previously seen graph structure (n=66), GlycoGen scores **60.6% (DFM) / 62.1% (MDLM)** vs GlycoBART's **13.6%** with non-overlapping CIs. Crucially, our loss function is at character-level, so the models (both DFM and MDLM) **learn graph structure implicitly**.\n\n \n## **4. Experimental workflows bottleneck**\nYou asked whether inference is the bottleneck at all. Two points:\n\n**(a) Inference is a bottleneck for offline batched annotation** (today's dominant workflow): peak processing, preprocessing, IUPAC parsing are negligible (0.1–1 ms/spec); the forward pass dominates. GlycoBART's SOTA setting would take **5 days** to batch-process one overnight acquisition session (5M spectra) on H200; GlycoGen takes 4 min to 1 hour.\n\n**(b) Speed is a hard limit on real-time annotation**, though not the only one. Instruments produce a spectrum every 5–10 ms; Data-Dependent Acquisition (DDA), which adjusts next-acquisition parameters from on-the-fly results, requires annotations under 10ms. Real-time fragment database search methods (Schweppe et al. 2020; Armony et al. 2023) lack neural accuracy.\n\nWe qualify speed gains: at matched compute (17 vs 36 forward passes, H200), GlycoGen is **4× faster batched, 1.7× unbatched, and +11pp more accurate**. We remove the \"2000×\" (max-vs-min) claim, replaced by \"1–2 orders of magnitude fewer forward passes at equal or higher accuracy\". We measured wall-clock at every K/beam, so camera-ready reports actual throughput.\n\n \n## **5. Exposition for non-specialists**\nCamera-ready will add a new Figure 1 (pipeline schematic), a half-page background section on glycomics, and a failure-mode analysis appendix; section 4.3 moves to appendix.\n\n \n| Condition | Met by |\n| --- | --- |\n| Multi-seed uncertainty | item 2, supplemental S1 |\n| Structure-level generalization | item 3, supplemental S2 |\n| Temper real-time/speed | items 1, 4 |\n| Exposition | item 5 |\n\nRunning the four contingent items strengthened the paper beyond meeting the conditions: multi-seed experimental error on every sweep, a three-way structure split with positive and negative results, refocused speed claims, measured wall-clock throughput, and a novel graph-invariance finding (60.6% DFM / 62.1% MDLM vs GlycoBART's 13.6%) that would not be here without your request for a structure-level breakdown. Thank you for pushing on this. \n\nWe hope this additional evidence supports accepting the paper."+ },+ "createdAt": "2026-08-04T01:45:40.275Z",+ "modifiedAt": "2026-11-19T16:52:46.629Z",+ "url": "https://openreview.net/forum?id=hhpivLTcN3¬eId=Jo6XaMar9l",+ "license": "CC-BY-4.0"+}
reviews/openreview/hhpivltcn3/notes/mx5pzlnobn.json modified
+++ b/reviews/openreview/hhpivltcn3/notes/mx5pzlnobn.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair ckkD","content": {- "metareview": "This paper introduces GlycoGen, a Discrete Flow Matching model for glycan structure prediction from MS/MS spectra, together with Crystallizing Flows, a deterministic simplex-propagation sampler with adaptive token commitment and early exit to speed up inference. The paper evaluates the method on CandyCrunch v2 under a run-stratified, per-spectrum protocol and includes extensive comparisons against alternative architectures including GlycoBART and a matched-architecture autoregressive Transformer, and several alternative sampling strategies.\n\nI read the reviews, author responses, and additional rebuttal experiments. The rebuttal substantially strengthens the paper with additional empirical validation: the authors provide three-seed retrains of all models, evaluate performance separately on seen versus genuinely unseen glycan structures, report end-to-end single-spectrum latency, and analyze performance across and under held-out instrument types. They also appropriately narrow several claims, withdrawing the stronger “de novo” generalization claim, limiting Pareto dominance to the low-NFE regime, and tempering the original speed framing.\n\nThe reviews were mixed, reflecting differing judgments about the significance of this narrower contribution and the strength of the real-time deployment motivation. In particular, some reviewers remained concerned that the improvement over the strongest matched baseline is moderate and that the highest-accuracy configurations do not fully satisfy the strictest real-time latency targets. At the same time, the rebuttal directly addressed most of the concrete experimental concerns raised during review, including multi-seed robustness, structure-level generalization, instrument dependence, and measured latency, and the authors appropriately revised claims where the new evidence did not support the original framing.\n\nOverall, I find the resulting contribution narrower than the original presentation but still technically solid and worthwhile. The method is simple, the controlled experiments are extensive, and the rebuttal directly addressed the most important concerns raised by the reviewers, including several with negative results that clarify the scope of the work. While questions remain about the practical importance of strict real-time annotation and the gain over the strongest matched baseline is moderate, I believe the combination of improved accuracy, substantially reduced sequential decoding cost, and empirical validation is sufficient for acceptance. I therefore recommend acceptance."+ "metareview": "This paper introduces GlycoGen, a Discrete Flow Matching model for glycan structure prediction from MS/MS spectra, together with Crystallizing Flows, a deterministic simplex-propagation sampler with adaptive token commitment and early exit to speed up inference. The paper evaluates the method on CandyCrunch v2 under a run-stratified, per-spectrum protocol and includes extensive comparisons against alternative architectures including GlycoBART and a matched-architecture autoregressive Transformer, and several alternative sampling strategies.\n\nI read the reviews, author responses, and additional rebuttal experiments. The rebuttal substantially strengthens the paper with additional empirical validation: the authors provide three-seed retrains of all models, evaluate performance separately on seen versus genuinely unseen glycan structures, report end-to-end single-spectrum latency, and analyze performance across and under held-out instrument types. They also appropriately narrow several claims, withdrawing the stronger “de novo” generalization claim, limiting Pareto dominance to the low-NFE regime, and tempering the original speed framing.\n\nThe reviews were mixed, reflecting differing judgments about the significance of this narrower contribution and the strength of the real-time deployment motivation. In particular, some reviewers remained concerned that the improvement over the strongest matched baseline is moderate and that the highest-accuracy configurations do not fully satisfy the strictest real-time latency targets. At the same time, the rebuttal directly addressed most of the concrete experimental concerns raised during review, including multi-seed robustness, structure-level generalization, instrument dependence, and measured latency, and the authors appropriately revised claims where the new evidence did not support the original framing.\n\nOverall, I find the resulting contribution narrower than the original presentation but still technically solid and worthwhile. The method is simple, the controlled experiments are extensive, and the rebuttal directly addressed the most important concerns raised by the reviewers, including several with negative results that clarify the scope of the work. While questions remain about the practical importance of strict real-time annotation and the gain over the strongest matched baseline is moderate, I believe the combination of improved accuracy, substantially reduced sequential decoding cost, and empirical validation is sufficient for acceptance. I therefore recommend acceptance.",+ "final_justification": "See metareview."},"createdAt": "2026-07-24T05:44:31.079Z",- "modifiedAt": "2026-11-18T15:25:12.703Z",+ "modifiedAt": "2026-11-19T05:03:17.115Z","url": "https://openreview.net/forum?id=hhpivLTcN3¬eId=mx5pzLnOBn","license": "CC-BY-4.0"}
reviews/openreview/hhpivltcn3/notes/qg7j5v68yf.json added
+++ b/reviews/openreview/hhpivltcn3/notes/qg7j5v68yf.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Qg7j5v68yf",+ "replyTo": "OPXuxc3oy4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer RsTy",+ "comment": "We thank you for the careful review and specific questions. We answer your four weaknesses in order, then your question and Limitations note. All additional tables are in our **Supplemental data** comment (S1–S3).\n\n\n \n## **W1. Necessity of improved inference speed.**\nYou mentioned that the necessity of improving inference speed was not clearly justified. Camera-ready will elaborate on experimental bottlenecks and why speed matters. \n\n**Unbatched single-spectrum latency is a limiting factor for novel glycomics workflows**. Recent LC-MS/MS instruments produce a spectrum every 5–10 ms (100–200 Hz). Data-Dependent Acquisition (DDA), which uses on-the-fly results to adjust the next acquisition parameters, requires real-time annotations under 10ms. The field has developed real-time fragment database search methods (see e.g. Schweppe et al. 2020; Armony et al. 2023) but they lack the accuracy of neural systems. AR methods that scale with GPUs, batch sizes, or beam params may improve batch latency but face a structural disadvantage on the single-spectrum speed needed for richer experimental workflows. \n\n**GlycoGen delivers both higher accuracy (see W3) and large speedups** compared to SOTA. On H200: unbatched, GlycoGen K=1 at 8.6 ms vs GlycoBART beam=1 at 183 ms (**21× speedup, +9pp accuracy**); batched: 0.046 ms vs 1.83 ms (**40× speedup**).\n\n\n \n## **W2. Code availability**\n**Anonymized code is now available** at a 4open.science submission (see separate Official Comment, per NeurIPS policy on links).\n\n\n \n## **W3. Experimental setup and improvement over SOTA**\n\nAll models in this paper are Transformers, differing in architecture, training objective, and role:\n* **GlycoBART** is our SOTA baseline: a BART-style seq2seq transformer (bidirectional encoder, autoregressive decoder), retrained from scratch on the leak-free split.\n* **GlycoGen-DFM** and **GlycoGen-MDLM** are the same 46M encoder-decoder transformer trained under two discrete-generative objectives (velocity flow on the probability simplex, and iterative unmasking). We report both to show that CF improves both DFM and MDLM, not just DFM.\n* **GlycoGen-AR seq2seq control** is our matched control for the AR objective: same 46M encoder-decoder as GlycoGen, changing only the objective and causal decoder mask (1,024 fewer parameters, the time embedding is not needed).\n* **Crystallizing Flows vs CTMC** is our sampler ablation: we compare CF to the default CTMC sampler on the same trained model, isolating the sampler contribution.\n\n**The gain is not modest: +11.6pp over GlycoBART SOTA** (80.92 → 92.51, S1). We attribute these gains to three factors:\n- **Architecture**: our 46M encoder-decoder beats 207M GlycoBART by **+9pp** at 4.5× fewer params (AR beam=1 90.39% vs GB beam=1 80.92%).\n- **Training objective**: replacing autoregression with a non-autoregressive discrete-generative objective (DFM or MDLM) adds **+2pp** at 52× fewer forward passes (DFM+CF K=8 92.51% vs AR beam=8 90.42%).\n- **Sampler**: CF improves the default CTMC sampler by **+1.82pp (DFM) and +1.91pp (MDLM)** at K=64, both outside experimental variance.\n\n\n \n## **W4. Paper readability for non-specialists**\n\nWe concede that the topic is niche for an AI audience. Camera-ready adds: \n* a half-page technical primer covering two concepts that trip up ML readers most (IUPAC strings vs glycan graphs, and per-spectrum vs sample-level)\n* a new Figure 1 with a data pipeline schematic\n* a failure-mode analysis in appendix.\n\nWe move section 4.3 to appendix to meet the page limit.\n\n\n \n## **Other questions and comments**\n\n**Q1. Is AR seq2seq a transformer, and does that make the gain minor?**\nYes, AR seq2seq is a Transformer. As detailed in W3, all four models here are transformers: GlycoBART (SOTA), GlycoGen-DFM and -MDLM (probing training objective), and the AR-seq2seq control (matched control for the AR objective). The latter is designed as a strong baseline by construction (90.42), to isolate archictecture and training objective improvement. The gain for GlycoGen-DFM/is not minor: **+11.6pp over GlycoBART SOTA and +2.1pp over the AR objective at 52× fewer forward passes** (see W3).\n\n**On your Limitations note** (_\"The experimental section is insufficient and limited to a small number of data scenarios\"_): our supplemental covers 3-seed retrains of every model across every sampler budget and beam width (S1), a structure-vs-string novelty breakdown (S2), and a per-instrument breakdown (S3).\n\n**On significance** (your lowest sub-score): our +11.6pp gain over SOTA at 4.5× fewer parameters and a large speed increase, together with graph-level structure learning (60.6% vs GlycoBART's 13.6% on structures seen only as different strings, S2), constitute a **significant improvement over SOTA**, and a method of interest for neural spectroscopy beyond glycomics.\n\n \n\nWe hope these clarifications, supplemental results, and camera-ready commitments support raising your overall rating."+ },+ "createdAt": "2026-08-03T20:39:50.833Z",+ "modifiedAt": "2026-11-19T16:52:46.853Z",+ "url": "https://openreview.net/forum?id=hhpivLTcN3¬eId=Qg7j5v68yf",+ "license": "CC-BY-4.0"+}
reviews/openreview/hhpivltcn3/notes/thdw4t8fhl.json added
+++ b/reviews/openreview/hhpivltcn3/notes/thdw4t8fhl.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "THdW4t8FhL",+ "replyTo": "Qg7j5v68yf",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer RsTy",+ "content": {+ "comment": "Thank you for the detailed rebuttal and the additional experiments. The response clarifies some of my concerns. Nevertheless, several central concerns remain.\n\n1. The real-time claim is not yet demonstrated under the relevant latency setting.\n\nThe headline numbers in Table 1 and Figure 2 are batched throughput measurements. Indeed, the matched AR baseline already reaches 452 spectra/s in the batched setting, which exceeds the stated 100–200 Hz acquisition rate. Therefore, the distinction between throughput and single-spectrum latency is essential.\n\nThe rebuttal newly reports an unbatched latency of 8.6 ms for GlycoGen when K=1. This is useful, but K=1 is not the recommended high-accuracy operating point: the reported 92.51% result uses K=8. Moreover, 8.6 ms satisfies a 100 Hz budget but not a 200 Hz budget of 5 ms. \n\n2. The SOTA performance is still not solid enough in current setting.\n\nThe +11.6 pp result is measured against the reproduced GlycoBART baseline, whereas the matched architecture AR control already reaches approximately 90.4%. Thus, the gain most directly attributable to the non AR objective and CF is approximately 2.1 pp, while most of the difference from GlycoBART comes from architecture and training-recipe changes. A 2.1 pp gain at substantially lower NFE can still be meaningful, but these sources of improvement should not be conflated.\n\nIn addition, Table 5 shows 92.50% for soft propagation versus 92.51% for CF at effective NFE=5. At NFE=33, greedy confidence reaches 92.77%, exceeding CF at 92.68%. Therefore, the statement that CF Pareto dominates every evaluated alternative at every NFE budget is too strong.\n\nIn summary, the rebuttal resolves the code concern and improves the presentation of some concerns. However, claims about problem motivation (Necessity), the degree of contribution of the method and gain is modest are not yet fully supported. I therefore maintain my rating.\n\nThank you for your reply again."+ },+ "createdAt": "2026-08-04T10:03:41.816Z",+ "modifiedAt": "2026-11-19T16:52:46.617Z",+ "url": "https://openreview.net/forum?id=hhpivLTcN3¬eId=THdW4t8FhL",+ "license": "CC-BY-4.0"+}
reviews/openreview/hhpivltcn3/notes/vcfypyfyjx.json added
+++ b/reviews/openreview/hhpivltcn3/notes/vcfypyfyjx.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "vCfypYFYJX",+ "replyTo": "C4Ae7SVhrT",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer VhHF",+ "comment": "We thank you for the detailed and constructive review. We take your points in the order you raised them, pairing each weakness with the question that follows from it. Question #2 led to a new representation-quality result that would not otherwise be in the paper. All new data tables are in our **Supplemental data** comment (S1–S3).\n\n \n\n## **1. Accuracy gains and the Pareto framing**\n(first weakness, Q1). We agree with all three of your positioning points and restate the contribution accordingly. \n\n(a) *The ~9pp win over GlycoBART comes from the DFM model at K=1, not from Crystallizing Flows.* Correct. The DFM objective delivers the accuracy jump over GlycoBART; CF adds the compute savings via early exit (see (b)). \n\n(b) *Crystallization over plain soft propagation is a wash on accuracy* (0.9251 vs 0.9250 at NFE 5). Also correct, so we present it as a compute result: early exit cuts effective forward passes from K to ≈K/2+1 at equal accuracy. \n\n(c) *MaskGIT-style greedy confidence matches us at NFE ≥ 33.* Yes, within the noise floor. \n\n**Pareto-framing.** We agree your framing more precisely captures the sampler's contribution: deterministic simplex propagation plus early exit wins in the low-NFE regime. Camera-ready will scope the Pareto-dominance claim to that regime rather than claim it universally. Still a meaningful contribution, as low-NFE speed matters most for real-time experimental workflows. Our accuracy and speed gains against SOTA (DFM: +11.6pp over GlycoBART) stand as a separate, strong contribution.\n\n**Error bars.** Every model is retrained on 3 random seeds (full sweeps in S1). GlycoGen's std stays **≤0.06pp at every K**; at K=64 Crystallizing Flows beats the default sampler by **+1.82pp (DFM)** and **+1.91pp (MDLM)**, both strongly outside experimental error. Checklist item 7 (report of error bars) changes from \"No\" to \"Yes\" for camera-ready.\n\n \n\n## **2. Structural diversity and structures held out entirely**\n(second weakness, Q2; _\"the single most important missing experiment\"_). You noted that grouping by source filename cannot guarantee structural novelty, and you are right: filenames are far from one-to-one with structures, since 94.6% of shared test structures appear in ≥2 training runs (99.0% of test spectra). We therefore split the test set by exact glycan graph isomorphism instead, and report results along with CIs in supplemental (S2).\n\n**On truly novel structure graphs (n=505):** all three models score near zero with overlapping CIs. Neither GlycoGen nor GlycoBART generalizes to unseen structural classes. We attribute this to the limited diversity you flagged, 500K spectra mapping to only 3,590 unique structures. To disambiguate \"_de novo_\" in the glycomics field's sense (no reference database at inference) from unseen-class generalization in the ML sense, we offer to **retitle the paper \"GlycoGen: Glycan Structure Prediction with Crystallizing Flows\"**.\n\n**A novel representation-quality finding: GlycoGen has partly learned the glycan graph, and strictly beats GlycoBART SOTA by 4.4×.** On strings unseen in training but isomorphic to structures seen in training (n=66), GlycoGen scores **60.6% (DFM) / 62.1% (MDLM)** vs GlycoBART's **13.6%**, with non-overlapping CIs (a 47-point improvement). Our loss is character-level only, with no supervision saying whether two different spellings share the same underlying graph structure, so string-only memorization cannot score above chance here. Both DFM and MDLM yield the same lift, making it a family property, and MDLM rises with K under CF (57.6% at K=1 to 62.1% at K≥16), so the sampler contributes as well.\n\nCamera-ready will add this as a new subsection in section 6, and mention it in the abstract as a secondary finding.\n\n \n\n## **3. Speed advantage like-for-like**\n(Q3). You correctly identified \"2000×\" as a max-vs-min ratio. We ran same-configuration comparisons on H200. At matched compute (17 vs 36 forward passes) GlycoGen is **4× faster batched, 1.7× unbatched, and +11pp more accurate**. Per-K throughput in section 4 below. \n\nRevised camera-ready abstract will say \"_1–2 orders of magnitude fewer forward passes than autoregressive beam-search baselines at equal or higher accuracy, across all beam widths and compute budgets_\", replacing the max-vs-min framing.\n\n \n\n## **4. Projected vs measured throughput**\n(Q4). Our 3-seed sweeps measured wall-clock directly at every K and every beam. Camera-ready will report measured throughput in Table 1 and Figure 2, dropping the K̃ ≈ K/2 + 1 projection. Batched ms/spec on H200, 3-seed retrains:\n\n**GlycoGen-DFM+CF:**\n| K | 1 | 8 | 32 | 64 |\n| --- | --- | --- | --- | --- |\n| Batched ms/spec | 0.046 | 0.201 | 0.673 | 1.320 |\n\n**GlycoBART:**\n| Beam | 1 | 8 | 32 |\n| --- | --- | --- | --- |\n| Batched ms/spec | 2.80 | 27.12 | 91.21 |\n\n \n\nWe hope these clarifications, supplemental results, and camera-ready commitments support keeping your Accept rating."+ },+ "createdAt": "2026-08-03T23:34:26.625Z",+ "modifiedAt": "2026-11-19T16:52:46.638Z",+ "url": "https://openreview.net/forum?id=hhpivLTcN3¬eId=vCfypYFYJX",+ "license": "CC-BY-4.0"+}
reviews/openreview/hhpivltcn3/notes/zdo6p5ud60.json added
+++ b/reviews/openreview/hhpivltcn3/notes/zdo6p5ud60.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "zdO6p5uD60",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Supplemental data supporting rebuttal responses",+ "comment": "Additional rebuttal-week experiments addressing questions from the AC and Reviewers: \n1. multi-seed retrains of every model, \n2. structure-level generalization, \n3. per-instrument analysis. \n\n \n\n## **S1. Full multi-seed sweeps** (top-1 acc. %, mean ± std in pp)\n\nWe retrained all models with 3 independent random seeds on the CandyCrunch v2 leak-free split (train n=378,879, val n=42,098, test n=76,774).\n\n \n\n**GlycoGen-DFM + Crystallizing Flows**:\n\n| K | 1 | 2 | 4 CF | 8 CF | 16 CF | 32 CF | 64 CF |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| Top-1 | 90.19 ±0.04 | 92.13 ±0.03 | 92.29 ±0.05 | 92.51 ±0.06 | 92.60 ±0.06 | 92.67 ±0.05 | 92.69 ±0.06 |\n| Eff. NFE | 1 | 2 | 3 | 5 | 9 | 17 | 33 |\n\n \n\n**GlycoGen-MDLM + CF**:\n\n| K | 1 | 2 | 4 CF | 8 CF | 16 CF | 32 CF | 64 CF |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| Top-1 | 89.73 ±0.17 | 91.86 ±0.11 | 92.08 ±0.12 | 92.31 ±0.12 | 92.41 ±0.11 | 92.47 ±0.11 | 92.49 ±0.11 |\n| Eff. NFE | 1 | 2 | 3 | 5 | 9 | 17 | 33 |\n\n \n\n**AR seq2seq** (46M control):\n\n| Beam | 1 | 2 | 4 | 8 | 16 | 32 |\n| --- | --- | --- | --- | --- | --- | --- |\n| Top-1 | 90.39 ±0.05 | 90.43 ±0.05 | 90.43 ±0.05 | 90.42 ±0.05 | 90.39 ±0.05 | 90.39 ±0.05 |\n| NFE | 33 | 65 | 131 | 261 | 523 | 1,045 |\n\n \n\n**GlycoBART** (207M SOTA baseline reproduction):\n\n| Beam | 1 | 2 | 4 | 8 | 16 | 32 |\n| --- | --- | --- | --- | --- | --- | --- |\n| Top-1 | 80.92 ±0.31 | 78.93 ±0.20 | 78.67 ±0.11 | 78.58 ±0.05 | 78.78 ±0.05 | 79.11 ±0.05 |\n| NFE | ~36 | ~72 | ~144 | ~288 | ~576 | ~1,157 |\n\n \n\n## **S2. Structure-level generalization**\n\nGlycans have a single structure but many valid IUPAC spellings as strings, so structures are matched by graph isomorphy, not by exact string. We split the test set by whether the ground truth glycan structure and/or string was seen at train time:\n\n| Test subset | DFM K=1 | DFM K=8 | DFM K=32 | MDLM K=1 | MDLM K=8 | MDLM K=32 | GlycoB β=1 | GlycoB β=8 | GlycoB β=32 |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Structure seen (76,269) | 90.81% | 93.11% | 93.26% | 90.48% | 92.89% | 93.09% | 81.72% | 79.16% | 79.62% |\n| Novel spelling of seen (66) | 60.6% [49, 71] | 57.6% [46, 69] | 57.6% [46, 69] | 57.6% [46, 69] | 60.6% [49, 71] | 62.1% [50, 73] | 13.6% [7, 24] | 13.6% [7, 24] | 13.6% [7, 24] |\n| Truly novel structure (505) | 0.8% [0, 2] | 1.8% [1, 3] | 1.8% [1, 3] | 0.0% [0, 1] | 0.2% [0, 1] | 0.2% [0, 1] | 3.6% [2, 6] | 2.8% [2, 5] | 2.6% [2, 4] |\n\n \n\n## **S3. Per-instrument analysis**\n\nCandyCrunch v2 is not single-instrument. The full dataset spans four instrument types: linear ion trap (51.6%), Orbitrap (22.7%), Bruker Amazon (15.5%), other (10.2%). GlycoGen K=1 scores 88.3% / 93.0% / 92.9% / 88.9% on each, respectively. We were mistaken and retract this limitation.\n\nWe trained held-out models by excluding one instrument at train time, and testing only on spectra from that held-out instrument (Wilson 95% CIs):\n\n \n\n| Instrument held out | DFM K=1 | MDLM K=1 |\n| --- | --- | --- |\n| Linear ion trap | 41.4% [40.9, 41.9] | 40.4% [39.9, 40.9] |\n| Orbitrap | 14.1% [13.6, 14.6] | 15.7% [15.2, 16.2] |\n\n \n\n## **Conclusions**\n\nThree main findings. First, **all headline claims survive seed variance**: experimental standard deviations are within 0.04 and 0.31 percentage points across independent seeds.\n\nSecond, **GlycoGen has partly learned the underlying glycan graph, not just memorized the training text**: on test spectra where a same structure appears in training but under a different IUPAC string, GlycoGen scores about 60% while GlycoBART scores about 14%, with non-overlapping confidence intervals. Neither model generalizes to truly novel, unseen structures however, so we offer to retitle the paper without the _de novo_ label.\n\nThird, **spectrum distributions vary strongly by instrument**: with all four families in training the model holds 88 to 93 percent on every family, but held out from one family accuracy drops to 41 percent on linear ion trap and 14 percent on Orbitrap (both DFM and MDLM). Generalization to unseen instruments is a real challenge: different instruments produce different fragmentation patterns, hence different spectra."+ },+ "createdAt": "2026-08-03T08:42:08.925Z",+ "modifiedAt": "2026-11-19T16:52:46.854Z",+ "url": "https://openreview.net/forum?id=hhpivLTcN3¬eId=zdO6p5uD60",+ "license": "CC-BY-4.0"+}