Inverse Modeling of Neural Recordings via Differentiable Biophysical Simulation
Update NeurIPS 2026 submission KFA1usL2kP: 5 notes
@openreview[bot] · 2026-11-24 15:49 UTC · 4c8cd3174388 ·
reviews/openreview/kfa1usl2kp/notes/4ncc1yyug8.json added
+++ b/reviews/openreview/kfa1usl2kp/notes/4ncc1yyug8.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "4nCc1YYug8",+ "replyTo": "KOgGnSdU5w",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you! That is a good point, you are right that the predicted latents could push the cell model into an implausible regime. We went back to check and the safe range for the model is approximately 3.6 nA and 4.7 nA for the soma and dendrite compartment respectively. The predicted values were below 3 nA. In any case, we will leave the biological plausibility claim out of the discussion since it is not something guaranteed, thanks for pointing this out!"+ },+ "createdAt": "2026-08-01T23:14:21.788Z",+ "modifiedAt": "2026-11-19T17:07:39.256Z",+ "url": "https://openreview.net/forum?id=KFA1usL2kP¬eId=4nCc1YYug8",+ "license": "CC-BY-4.0"+}
reviews/openreview/kfa1usl2kp/notes/7ucv7j8pp0.json modified
+++ b/reviews/openreview/kfa1usl2kp/notes/7ucv7j8pp0.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair yjBZ","content": {- "metareview": "**Summary**\nThe authors propose a novel, differentiable pipeline coupling biophysical membrane dynamics with an extracellular volume conductor model. By using spike times as discrete anchors in the loss function, the method jointly infers a time-varying input current and probe-relative position for recorded neurons.\n\n**Strengths**\n\n* **Novel Concept:** A highly creative, physically grounded approach well-suited for the Concept and Feasibility track.\n* **Transparency:** Honest and clear presentation of limitations, specifically regarding subthreshold voltage drift.\n\n**Key Weaknesses & Areas for Rebuttal**\n\n* **Missing Quantitative Evaluation (Reviewer QgVJ):** The core biophysical claim is recovering per-neuron input current. The authors must provide quantitative metrics (e.g., correlation or MSE) comparing the inferred drive against the known ground-truth current on the synthetic data.\n* **Practical Value vs. Compute Cost (Reviewer Ee7H):** Localization gains are marginal over fast baselines (39.7 µm vs 42.8 µm) despite vastly higher compute costs (~1 GPU hour/cell). Please better articulate the practical payoff of this expensive joint-fit approach.\n* **Scalability & Robustness (Reviewers QgVJ, Ee7H):** Address the sharp accuracy drop when scaling from 2 to 4 jointly fitted units. Additionally, test robustness by inverting synthetic data using a *different* neuron model than the one used to generate it.\n* **Clarification (Reviewer 21gh):** Briefly clarify the relationship between this smoothing/anchoring scheme and standard surrogate gradient methods in SNNs."+ "metareview": "**Summary**\nThe authors propose a novel, differentiable pipeline coupling biophysical membrane dynamics with an extracellular volume conductor model. By using spike times as discrete anchors in the loss function, the method jointly infers a time-varying input current and probe-relative position for recorded neurons.\n\n**Strengths**\n\n* **Novel Concept:** A highly creative, physically grounded approach well-suited for the Concept and Feasibility track.\n* **Transparency:** Honest and clear presentation of limitations, specifically regarding subthreshold voltage drift.\n\n**Key Weaknesses & Areas for Rebuttal**\n\n* **Missing Quantitative Evaluation (Reviewer QgVJ):** The core biophysical claim is recovering per-neuron input current. The authors must provide quantitative metrics (e.g., correlation or MSE) comparing the inferred drive against the known ground-truth current on the synthetic data.\n* **Practical Value vs. Compute Cost (Reviewer Ee7H):** Localization gains are marginal over fast baselines (39.7 µm vs 42.8 µm) despite vastly higher compute costs (~1 GPU hour/cell). Please better articulate the practical payoff of this expensive joint-fit approach.\n* **Scalability & Robustness (Reviewers QgVJ, Ee7H):** Address the sharp accuracy drop when scaling from 2 to 4 jointly fitted units. Additionally, test robustness by inverting synthetic data using a *different* neuron model than the one used to generate it.\n* **Clarification (Reviewer 21gh):** Briefly clarify the relationship between this smoothing/anchoring scheme and standard surrogate gradient methods in SNNs.",+ "final_justification": "The reviewers reached a positive consensus on this submission (scores: 5, 4, 4), agreeing that it presents a highly novel, physically grounded approach well-suited for the Concept and Feasibility track. While reviewers initially raised valid concerns regarding computational costs, scalability, and the lack of quantitative evaluation on synthetic data, the authors' rebuttal and additional ablations (such as testing alternative cell models) sufficiently addressed these reservations. Given the innovative nature of the end-to-end differentiable pipeline and the authors' transparent discussion of its limitations, I recommend acceptance."},"createdAt": "2026-07-20T06:16:31.589Z",- "modifiedAt": "2026-11-18T15:25:36.949Z",+ "modifiedAt": "2026-11-19T05:03:34.734Z","url": "https://openreview.net/forum?id=KFA1usL2kP¬eId=7uCV7j8Pp0","license": "CC-BY-4.0"}
reviews/openreview/kfa1usl2kp/notes/koggnsdu5w.json added
+++ b/reviews/openreview/kfa1usl2kp/notes/koggnsdu5w.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "KOgGnSdU5w",+ "replyTo": "6zlkvXc6c4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer Ee7H",+ "content": {+ "comment": "I thank the authors for their response. I appreciate the clarifications and the additional results, and will raise my score to a 4. \n\nNote that the argument 'it is produced by solving biophysical voltage equations, therefore it is within possible trajectories of Morris-Lecar dynamics and thus biophysically plausible' does not hold up: these models readily produce non-physiological responses, especially when the input drive exceeds the regime for which the excitable dynamics were validated. I would not include this argument in the manuscript."+ },+ "createdAt": "2026-08-01T07:35:08.196Z",+ "modifiedAt": "2026-11-19T17:07:39.092Z",+ "url": "https://openreview.net/forum?id=KFA1usL2kP¬eId=KOgGnSdU5w",+ "license": "CC-BY-4.0"+}
reviews/openreview/kfa1usl2kp/notes/mwyklruhxc.json added
+++ b/reviews/openreview/kfa1usl2kp/notes/mwyklruhxc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "mWYkLRUhxC",+ "replyTo": "OPpJhY09mx",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thanks for raising these follow ups, we will expand the discussion of this in the manuscript as suggested.\n\n> Would you argue that [the sub-threshold voltage reconstruction] meaningfully resembles a neuronal voltage trace, and that it would be useful in this form?\n\nIt is meaningful in so far as it is produced by solving biophysical voltage equations, so it is within possible trajectories of typical Morris-Lecar dynamics and thus biophysically plausible. For reference, Figure 1 in [Meier2015] plots a canonical spike of the Morris-Lecar cell, and our recovered trace shows a similiar qualitative profile aligned at the recorded spike time, albeit with much stronger depolarization during the refactory period. Notably, many other trajectories could give rise to the same signal, so this represents just a guess about the cells actual trajectory. However, the concrete prediction is practically valuable because it gives us an idea about the firing regime that the cells might have been in, e.g. whether they were in a bursting state or just spontanously depolarizing.\n\n[Meier2015] Meier et al., 2015 \"Bursting Regimes in a Reaction-Diffusion System with Action Potential-Dependent Equilibrium\". PLOS.\n\n\n> You chose a Morris–Lecar model for your experiments. Could you discuss how impactful the model choice is to your framework, and how the strategy for selecting the right model would differ from (or align with) an SBI-based approach?\n\nYes, the ablation is insightful here. We re-ran the inverse fit using the Motoneuron model, reported below. The choice of model does not significantly affect the localization performance, although small differences exist for some cells (e.g. c19 where Morris-Lecar achives better localization, or c26 where the Motoneuron outperforms). This suggests that the inverse algorithm does not leverage the ion-channel level differences of the cell models in a meaningful way. Thus, choosing a cell type is more akin to choosing a prior belief of what cells are likely in the system , not something that can be inferred from the quality of the fit (e.g. SPE-1 is an in vivo system likely better described by Morris-Lecar than the in vitro motoneuron model even if it does not make a difference for the localization fit). This differs from problem settings that are common in SBI where an explicit goal is to figure out ion-channel level quantities and the cell model thus plays a more significant role in the optimization outcome (e.g. Tanoh et al. where the input current to the cell is kept constant to be able to infer channel-level quantities). We will discuss this in more detail in the revised manuscript. \n\n## SPE-1 localization on the Zhao 11 using different cell models\n\n### Morris-Lecar as included in the paper, copied here for easy reference:\n\n| | c14 | c15 | c16 | c19 | c24 | c26 | c28 | c29 | c37 | c45 | c46 | mean | median | std |\n|------------|------------|------------|-----------|------------|-------------|-------------|------------|------------|------------|------------|------------|-------|--------|-------|\n| MAE | 40.84±0.03 | 26.39±0.05 | 5.19±0.20 | 49.00±0.05 | 260.49±0.02 | 243.91±0.00 | 25.65±0.05 | 62.17±0.02 | 37.77±0.00 | 25.48±0.10 | 39.76±0.04 | 74.24 | 39.76 | 85.12 |\n| Accuracy | 100.0±0.0 | 100.0±0.0 | 100.0±0.0 | 100.0±0.0 | 0.0±0.0 | 0.0±0.0 | 100.0±0.0 | 0.0±0.0 | 100.0±0.0 | 100.0±0.0 | 100.0±0.0 | 72.7 | 100.0 | 44.5 |\n| Train Time | 3:53 | 2:04 | 2:49 | 2:01 | 2:28 | 2:28 | 3:13 | 1:23 | 0:40 | 3:18 | 2:42 | 2:27 | 2:28 | 0:52 |\n\n### Re-fit using Motoneuron model:\n\n\n| | c14 | c15 | c16 | c19 | c24 | c26 | c28 | c29 | c37 | c45 | c46 | mean | median | std |\n|------------|------------|------------|-----------|------------|-------------|-------------|------------|------------|------------|------------|------------|-------|--------|-------|\n| MAE | 40.01±0.03 | 25.48±0.01 | 3.17±0.25 | 56.76±0.49 | 260.46±0.02 | 230.49±0.02 | 25.49±0.13 | 60.05±0.09 | 36.50±0.00 | 23.98±0.01 | 39.71±0.02 | 72.92 | 39.71 | 82.96 |\n| Accuracy | 100.0±0.0 | 100.0±0.0 | 100.0±0.0 | 0.0±0.0 | 0.0±0.0 | 0.0±0.0 | 100.0±0.0 | 0.0±0.0 | 100.0±0.0 | 100.0±0.0 | 100.0±0.0 | 63.6 | 100.0 | 48.1 |\n| Train Time | 3:27 | 1:26 | 1:12 | 2:37 | 2:24 | 2:50 | 1:10 | 1:07 | 0:01 | 1:28 | 1:51 | 1:47 | 1:28 | 0:56 |"+ },+ "createdAt": "2026-07-31T21:45:38.920Z",+ "modifiedAt": "2026-11-19T17:07:39.882Z",+ "url": "https://openreview.net/forum?id=KFA1usL2kP¬eId=mWYkLRUhxC",+ "license": "CC-BY-4.0"+}
reviews/openreview/kfa1usl2kp/notes/oppjhy09mx.json added
+++ b/reviews/openreview/kfa1usl2kp/notes/oppjhy09mx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "OPpJhY09mx",+ "replyTo": "6zlkvXc6c4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer Ee7H",+ "content": {+ "comment": "I thank the authors for their responses. I concede that I may have underestimated the originality of the approach, though I remain unconvinced that it is groundbreaking enough for a \"concept and feasibility\" track. That judgment is admittedly subjective, and since I appear to be in the minority on this point, I will not let it affect my final score.\n\nI still have concerns about the limited scope of the experimental section, even for a proof of concept. I find the argument that localization is not the end goal a somewhat convenient way to sidestep the discussion of gains versus computational cost. This deserves more discussion, even if only in the manuscript itself. I have two follow-up questions for the authors:\n\n- You note that the sub-threshold voltage reconstruction currently achieved is modest. Would you argue that it meaningfully resembles a neuronal voltage trace, and that it would be useful in this form?\n- You chose a Morris–Lecar model for your experiments. Could you discuss how impactful the model choice is to your framework, and how the strategy for selecting the right model would differ from (or align with) an SBI-based approach?\n\nTo be clear, I am not requesting additional experiments, which would be unreasonable given the short rebuttal window. I will also factor the additional ablation experiment into my final recommendation."+ },+ "createdAt": "2026-07-31T10:28:30.258Z",+ "modifiedAt": "2026-11-19T17:07:39.881Z",+ "url": "https://openreview.net/forum?id=KFA1usL2kP¬eId=OPpJhY09mx",+ "license": "CC-BY-4.0"+}