potentialpaper

Structure and Semantic-Guided Closed-Loop Medical Image Anomaly Detection via Multi-Agent Collaboration

Update NeurIPS 2026 submission LplVYRTK4x: 13 notes

@openreview[bot] · 2026-11-24 15:49 UTC · 05fe529e6764 ·

Evidence

reviews/openreview/lplvyrtk4x/notes/cowgcnuwbn.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/cowgcnuwbn.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "CowgcnUwbn",
+ "replyTo": "eFGZT9H5Cf",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer EBqc -- Part 2/3",
+ "comment": "**Q3 & W1.2: Claim inventory construction and robustness**\n\n**A3:** We thank the reviewer for raising this concern. We clarify how visually grounded claims are defined and verified, and evaluate robustness to incomplete, noisy, random, and different-source inventories.\n\n**Claim definition and verification.** RadGraph and RadGraph-XL [6,15] were used to extract and structure candidate entities and relations, but they do not directly provide a visual-grounding label. We operationally define a claim as visually grounded when it (i) can be assessed from a single chest radiograph, (ii) describes a directly observable normal property of a named thoracic structure, and (iii) concerns its location, contour, spatial distribution, directional extension, or relationship with neighboring structures. We excluded pathology or diagnosis, uncertainty, patient history, and other information not verifiable from the current image. Semantically equivalent candidates were then canonicalized and merged.\n\nFor this rebuttal, all 122 retained claims were independently reviewed by two researchers with medical-imaging expertise, with disagreements resolved by consensus. \n\n**Robustness analysis.** We evaluated the following perturbations:\n\n- **Retain 75%/50%:** randomly remove claims to simulate incompleteness.\n- **Noise 20%/40%:** replace valid claims with pathological, irrelevant, or non-visually-grounded statements.\n- **Random inventory:** replace all 122 claims with length-matched report statements without normality, anatomy, or visual-grounding filtering.\n- **Different-source inventory:** construct a same-size inventory from ReXGradient-160K [1] using the same extraction and filtering procedure.\n- **No semantic inventory:** remove claim-based semantic guidance.\n\nFor stochastic perturbations, results are averaged over five independently sampled inventories. AUC-PR (%) is reported below.\n\nTable 3. Robustness to claim-inventory perturbations.\n\n| Claim-inventory setting | ZhangLab | CheXpert | COVIDx |\n|---|---:|---:|---:|\n| Retain 75% | 92.89 ± 0.33 | 78.64 ± 0.48 | 90.78 ± 0.41 |\n| Retain 50% | 92.21 ± 0.41 | 77.74 ± 0.56 | 89.96 ± 0.49 |\n| Noise 20% | 92.63 ± 0.37 | 78.37 ± 0.51 | 90.52 ± 0.43 |\n| Noise 40% | 91.94 ± 0.46 | 77.36 ± 0.61 | 89.67 ± 0.56 |\n| Different-source inventory | 93.28 ± 0.29 | 79.14 ± 0.13 | 91.23 ± 0.26 |\n| Random inventory | 91.66 ± 0.50 | 76.55 ± 0.65 | 89.43 ± 0.59 |\n| No semantic inventory | 91.58 ± 0.47 | 76.38 ± 0.62 | 89.35 ± 0.55 |\n| Original verified inventory | 93.27 ± 0.18 | 79.16 ± 0.27 | 91.26 ± 0.22 |\n\nPerformance degrades gradually as the inventory becomes less complete or more contaminated, while moderate removal or noise remains consistently better than removing semantic guidance. The different-source inventory also remains close to the original, indicating limited dependence on a particular institution or reporting style. In contrast, the random inventory performs similarly to removing the inventory, confirming that the gains arise from normal claims.\n\nThis robustness is further supported by image-conditioned VLM selection and subsequent semantic verification, which filter unsupported claims before reconstruction and correct semantic discrepancies during refinement. \n\n[1] ReXGradient-160K: A Large-Scale Publicly Available Dataset of Chest Radiographs with Free-text Reports, arXiv 2025.\n\n\n----\n\n\n**Q4 & W4.1: Computational cost of closed-loop inference**\n\n**A4:** Thank you for raising this practicality concern. We profiled all methods on the same A100 GPU with identical input resolution and timing protocol. Latency was measured end-to-end, excluding model loading and offline preprocessing.\n\nTable 4. Computational cost at inference.\n\n| Method / setting | Avg. rounds | Early-stop rate | Time/image | Peak memory |\n|:--|--:|--:|--:|--:|\n| SimSID | — | — | 1.84 s | 6.7 GB |\n| DeCo-Diff | — | — | 12.63 s | 15.4 GB |\n| $\\mathrm{S}^{2}$Agent, single round | 1.00 | — | 9.7 s | 18.7 GB |\n| $\\mathrm{S}^{2}$Agent, full closed loop | 1.91 | 94.4% | 18.5 s | 19.8 GB |\n| $\\mathrm{S}^{2}$Agent, fixed four rounds | 4.00 | 0% | 38.8 s | 20.0 GB |\n\nThe full closed loop requires 1.91 rounds on average, with 94.4% of samples terminating before reaching the four-round limit. Because refinement rounds share model parameters and are executed sequentially, they primarily increase latency rather than peak memory. Early stopping therefore reduces inference time by approximately 52.3% compared with fixed four-round refinement. \n\nAlthough the full closed-loop $\\mathrm{S}^{2}$Agent is slower than the single-pass baselines due to iterative reconstruction and dual-space verification, these results quantify its additional cost and show that early stopping provides a substantially better performance–efficiency trade-off. We will add these measurements and discuss the inference overhead in the revision."
+ },
+ "createdAt": "2026-08-02T02:05:30.740Z",
+ "modifiedAt": "2026-11-19T17:06:41.315Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=CowgcnUwbn",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lplvyrtk4x/notes/fvvermsf5f.json modified

+++ b/reviews/openreview/lplvyrtk4x/notes/fvvermsf5f.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair nPjG",
"content": {
- "metareview": "Initial metareview: needs clarification\n\nS²Agent reformulates reconstruction-based unsupervised medical anomaly detection as an iterative loop. A planner retrieves a sample-specific matched tree from a hierarchical memory tree as a structural constraint and selects normal-only claims from a claim inventory using BiomedCLIP as a semantic constraint. A reconstructor then generates a normal reference. A detector verifies in both spaces and returns feedback; the loop runs up to 4 rounds with early stopping. Reported gains over 10 baselines on ZhangLab, CheXpert (PA), and COVIDx.\n\nAll three reviewers independently raise chest-X-ray-only validation and want finer-grained ablation of the memory tree; EBqc and q732 both want compute cost and robustness-to-external-components analysis. EBqc’s review is the most thorough and its concerns all seem answerable.\n\nSection 4.1 says results are averaged over five independent runs, but neither Tables 1 or 2 show a standard deviation, and the checklist answers \"Yes\" to statistical significance with the justification that it's \"provided in Section 4\" but doesn’t appear to be there. This matters especially because the margins are small: on ZhangLab, AUC-PR 93.27 vs PDD's 92.43 and AUC-ROC 94.81 vs 94.02, i.e. under a percentage point. The ablation deltas are the same magnitude, so \"Tree consistently outperforms Flat\" and \"Both beats either feedback alone\" are unsupported assertions at the momemnt.\n\n(not seen by reviewers). Appendix C states the claim inventory is built from MIMIC-CXR and CheXpert Plus and \"does not use any image and report from the experimental benchmarks.\" But CheXpert is one of the three benchmarks, and CheXpert Plus is that dataset augmented with its radiology reports. Even if only normal, anatomy-level claims are retained and merged into the 122 canonical types, which wouild make the practical leakage small, the statement of no-overlap is inaccurate.\n\nThe Detector generates the reconstruction's caption using the same claim-based captioning pipeline as the Planner (BiomedCLIP wiht the same inventory). So the semantic half of the loop optimises the reconstruction toward what one VLM scores as normal, using that same VLM as judge. Not circular in the evaluation sense, but it does mean the semantic convergence of the loop is partly self-referential, and sensitivity to VLM choice becomes quite critical.\n\nAll three reviewers note chest-X-ray-only evaluation under a general \"medical anomaly detection\" banner; the claim inventory is chest-specific by construction, so the title and framing should narrow.\n\nCompute cost (all three reviewers) is trivially reportable and should simply be added."
+ "metareview": "Initial metareview: needs clarification\n\nS²Agent reformulates reconstruction-based unsupervised medical anomaly detection as an iterative loop. A planner retrieves a sample-specific matched tree from a hierarchical memory tree as a structural constraint and selects normal-only claims from a claim inventory using BiomedCLIP as a semantic constraint. A reconstructor then generates a normal reference. A detector verifies in both spaces and returns feedback; the loop runs up to 4 rounds with early stopping. Reported gains over 10 baselines on ZhangLab, CheXpert (PA), and COVIDx.\n\nAll three reviewers independently raise chest-X-ray-only validation and want finer-grained ablation of the memory tree; EBqc and q732 both want compute cost and robustness-to-external-components analysis. EBqc’s review is the most thorough and its concerns all seem answerable.\n\nSection 4.1 says results are averaged over five independent runs, but neither Tables 1 or 2 show a standard deviation, and the checklist answers \"Yes\" to statistical significance with the justification that it's \"provided in Section 4\" but doesn’t appear to be there. This matters especially because the margins are small: on ZhangLab, AUC-PR 93.27 vs PDD's 92.43 and AUC-ROC 94.81 vs 94.02, i.e. under a percentage point. The ablation deltas are the same magnitude, so \"Tree consistently outperforms Flat\" and \"Both beats either feedback alone\" are unsupported assertions at the momemnt.\n\n(not seen by reviewers). Appendix C states the claim inventory is built from MIMIC-CXR and CheXpert Plus and \"does not use any image and report from the experimental benchmarks.\" But CheXpert is one of the three benchmarks, and CheXpert Plus is that dataset augmented with its radiology reports. Even if only normal, anatomy-level claims are retained and merged into the 122 canonical types, which wouild make the practical leakage small, the statement of no-overlap is inaccurate.\n\nThe Detector generates the reconstruction's caption using the same claim-based captioning pipeline as the Planner (BiomedCLIP wiht the same inventory). So the semantic half of the loop optimises the reconstruction toward what one VLM scores as normal, using that same VLM as judge. Not circular in the evaluation sense, but it does mean the semantic convergence of the loop is partly self-referential, and sensitivity to VLM choice becomes quite critical.\n\nAll three reviewers note chest-X-ray-only evaluation under a general \"medical anomaly detection\" banner; the claim inventory is chest-specific by construction, so the title and framing should narrow.\n\nCompute cost (all three reviewers) is trivially reportable and should simply be added.",
+ "final_justification": "All three of my outstanding points have been addressed. The authors supplied mean ± std over the five runs for the headline comparisons and key ablations, plus run-wise paired t-tests on common splits/seeds, which support the main claims (significant everywhere except vs. SimSID on COVIDx AUC-PR); they acknowledged that the Appendix C no-overlap statement was inaccurate given CheXpert Plus, and demonstrated the point is not material by rebuilding the inventory from ReXGradient-160K alone with essentially unchanged results; lastly, the cross-VLM experiments (BiomedCLIP/MedCLIP in both Planner and Detector roles) show that the benefit of the semantic loop benefit is not an artefact of shared BiomedCLIP preferences. To address the concerns of the reviewers, the authors added fine-grained Memory Tree ablations, node-to-anatomy analysis, claim-inventory robustness studies, pathology-stratified results, and compute cost, and have committed to narrowing the title and framing to chest radiography. Reviewer EBqc raised their score from borderline reject to borderline accept, EY5N stands by their accept, and q732 remains at borderline accept. I am maintaining Accept (poster), conditional on the new analyses, the corrected Appendix C statement, and the narrowed framing appearing in the camera-ready."
},
"createdAt": "2026-07-22T08:11:08.279Z",
- "modifiedAt": "2026-11-18T15:25:50.669Z",
+ "modifiedAt": "2026-11-19T05:03:40.824Z",
"url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=fvVeRmSf5F",
"license": "CC-BY-4.0"
}

reviews/openreview/lplvyrtk4x/notes/fyiw3l0mgy.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/fyiw3l0mgy.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "FyiW3L0MGy",
+ "replyTo": "R45X6M8Cwa",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer q732 -- Part 2/2",
+ "comment": "**Q5: Sensitivity to caption and claim errors**\n\n**A5:** Thank you for raising this robustness question. Because the initial caption is deterministically verbalized from the selected claims, missing or incorrect claims directly lead to incomplete or corrupted semantic conditions. We therefore perturb the selected claim sets in two ways: (1) randomly removing valid claims to simulate incomplete selection, and (2) replacing valid claims with pathological or irrelevant statements to simulate incorrect selection. Each setting is evaluated over five independent perturbations, and we report the mean and standard deviation using AUC-PR (%).\n\nTable 2. Robustness to claim perturbations.\n\n| Claim setting | ZhangLab | CheXpert | COVIDx |\n|:--|--:|--:|--:|\n| Retain 75% | 92.89 ± 0.33 | 78.64 ± 0.48 | 90.78 ± 0.41 |\n| Retain 50% | 92.21 ± 0.41 | 77.74 ± 0.56 | 89.96 ± 0.49 |\n| Noise 20% | 92.63 ± 0.37 | 78.37 ± 0.51 | 90.52 ± 0.43 |\n| Noise 40% | 91.94 ± 0.46 | 77.36 ± 0.61 | 89.67 ± 0.56 |\n| Random claims | 91.66 ± 0.50 | 76.55 ± 0.65 | 89.43 ± 0.59 |\n| **Original verified claims** | **93.27 ± 0.18** | **79.16 ± 0.27** | **91.26 ± 0.22** |\n\nPerformance degrades gradually as claim corruption increases, while mild perturbations cause only limited drops. Random claims approach the no-semantic baseline, indicating that the gains arise from visually grounded claims rather than arbitrary text.\n\n\n----\n\n\n**W1: Unclear distinction between multi-agent design and a modular pipeline**\n\n**A6:** Thank you for raising this important concern. We would like to clarify that the term multi-agent is used in a role-specialized functional sense, rather than to describe a fully autonomous or jointly learned agent system. Our contribution does not rely on the terminology itself, but on the closed-loop coordination of three specialized components through explicit structural and semantic state updates.\n\nThe framework differs from a conventional modular pipeline because the reconstruction conditions are not fixed. After each reconstruction, the Detector independently evaluates structural and semantic consistency and returns actionable feedback to the Planner. Structural feedback reweights the matched-tree nodes, while semantic feedback revises the normal claim constraint. Both updates directly alter the conditions used in the next reconstruction round.\n\nThe experiments support the effectiveness of this feedback mechanism. Performance consistently improves with additional refinement rounds, and combining structural and semantic feedback outperforms using either branch alone. \n\nTo avoid over-framing, we will clarify that $\\mathrm{S}^{2}$Agent is a role-specialized closed-loop framework rather than a fully autonomous or jointly learned multi-agent system.\n\n\n----\n\n\n**W3: External-component robustness**\n\n**A7:** Thank you for highlighting this concern. To clarify, no separate learned claim-extraction or caption-generation model is used. BiomedCLIP selects relevant claims from a predefined claim inventory, which are converted into semantic captions through a deterministic template. Qwen2.5-7B-Instruct and unCLIP then perform constrained semantic revision and reconstruction, respectively.\n\nWe address reproducibility and robustness from three perspectives. A1 reports end-to-end latency, average refinement rounds, and peak GPU memory; A2 provides the exact LLM checkpoint, complete prompts, and input context; and A5 evaluates sensitivity to missing and corrupted claims, showing gradual degradation as semantic corruption increases.\n\nTo examine sensitivity to the LLM choice, we replace Qwen2.5-7B-Instruct with Llama-3.1-8B-Instruct while keeping the others unchanged.\n\nTable 3. Sensitivity to the LLM-Based Semantic Modifier in terms of AUC-PR (%).\n\n| Semantic modifier | ZhangLab | CheXpert | COVIDx |\n|:--|--:|--:|--:|\n| Llama-3.1-8B-Instruct | 93.25 ± 0.20 | 79.14 ± 0.29 | 91.27 ± 0.24 |\n| Qwen2.5-7B-Instruct | 93.27 ± 0.18 | 79.16 ± 0.27 | 91.26 ± 0.22 |\n\nThe two LLM backbones achieve comparable performance across all three datasets, suggesting limited sensitivity to the choice of LLM backbone. \n\nWe acknowledge that the current study does not systematically compare alternative VLM or reconstruction backbones and therefore does not establish full backbone independence. If accepted, we will clarify the roles and configurations of all external components and incorporate the above analyses into the final version.\n\n\n----\n\n\n**Limitations: Practical scope and model dependencies**\n\n**A8:** Thank you for highlighting these limitations. We agree that the current evidence is limited to 2D chest X-rays and does not establish cross-modality generalization. The method also depends on pretrained VLM/LLM components, may be affected by missing or incorrect claims, and introduces additional inference cost through iterative refinement. These issues are addressed in A3, A2&A7, A5, and A1, respectively, and will be stated explicitly in the final version."
+ },
+ "createdAt": "2026-08-02T02:12:15.330Z",
+ "modifiedAt": "2026-11-19T17:06:41.065Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=FyiW3L0MGy",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lplvyrtk4x/notes/jnknrerphz.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/jnknrerphz.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "JNkNrErpHz",
+ "replyTo": "zwkxMC1skL",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer EY5N -- Part 2/2",
+ "comment": "**Q1: Typical correction patterns across multiple cases**\n\n**A4:** Thank you for this helpful suggestion. As the rebuttal interface does not support uploading additional figures, we provide concise textual summaries of three representative cases below. These cases illustrate typical correction patterns observed during closed-loop refinement.\n\n*Case 1: Residual abnormal content.* In the first case, the initial reconstruction substantially reduces the abnormal appearance but leaves a localized patchy opacity in the right lower-lung field. The Detector identifies low consistency in the corresponding lower-lung matched-tree nodes, together with a mismatch with the normal semantic description of the lung-field appearance. The Planner consequently updates the relevant structural weights and refines the corresponding normal semantic constraints, enabling the next reconstruction to further suppress the residual opacity while preserving the surrounding normal lung texture.\n\n*Case 2: Unintended modification of a normal region.* This case corresponds to Figure 2. The first reconstruction corrects the abnormal response around the right perihilar and lower-lung regions, but introduces focal grayscale heterogeneity and local darkening in the normal left upper-lateral lung field. The Detector identifies the missing low-contrast intercostal background, and the Planner restores the corresponding normal semantic constraint. The second reconstruction preserves the successful abnormal-to-normal correction while recovering a more consistent appearance in the normal region.\n\n*Case 3: Local anatomical distortion.* In the third case, the first reconstruction reduces the abnormal response but slightly flattens the left diaphragmatic contour and alters its spatial relationship with the lower-lung boundary. Matched-tree verification detects reduced consistency in the node responses associated with this region. The Planner then reweights the corresponding matched-tree nodes, increasing the influence of the relevant normal structural priors in the next round. The subsequent reconstruction restores the normal arcuate diaphragmatic contour and a more plausible spatial relationship with the lower-lung boundary, while preserving the correction of the abnormal region.\n\nOverall, the closed loop mainly addresses two recurring reconstruction failures: residual abnormal content that is insufficiently corrected in the first round, and unintended modifications introduced into originally normal regions. Structural feedback primarily repairs anatomical inconsistencies, whereas semantic feedback helps restore missing normal observations and suppress unsupported content.\n\n\n----\n\n\n**Q2: Contribution of the Memory Tree structure**\n\n**A5:** Thank you for this important question. As shown in Table 2 of the original manuscript, we include a direct ablation of the Memory Tree by replacing it with a Flat Memory. Its consistently lower performance across all three datasets demonstrates that the improvement does not arise solely from prototype-based memory, but also from organizing normal patterns hierarchically.\n\nTo further isolate the contributions of different components of the Memory Tree, we conducted the following controlled ablations.\n\nTable 2. AUC-PR (%) ablations of the Memory Tree.\n\n| Variant | ZhangLab | CheXpert | COVIDx |\n|:--|--:|--:|--:|\n| Flat Memory | 91.86 | 76.64 | 89.71 |\n| Random topology | 92.28 | 77.40 | 90.18 |\n| Without node reweighting | 92.85 | 78.40 | 90.80 |\n| **Full Memory Tree** | **93.27** | **79.16** | **91.26** |\n\nThe Flat Memory comparison isolates the contribution of hierarchical prototype organization. The Random-topology variant retains the same tree depth, branching factor, number of nodes, memory capacity, and training settings as the full model, but replaces the data-driven organization of memory pools with a random assignment. Its consistently lower performance indicates that the benefit is not merely due to using multiple memory pools; the data-driven coarse-to-fine organization also contributes to the improvement. The Without-node-reweighting variant retains the learned tree topology and matched-tree retrieval but disables Detector-guided updates of node contributions during closed-loop refinement. Its performance degradation confirms that feedback-guided structural refinement provides an additional benefit beyond the static tree representation.\n\nOverall, these results show that the Memory Tree contributes through three complementary aspects: hierarchical prototype organization, data-driven topology construction, and feedback-guided node refinement. The improvement therefore cannot be attributed simply to increased memory capacity.\n\n\n----\n\n\n**Paper Formatting Concerns: Unremoved checklist instruction block**\n\n\n**A6:** Thank you for identifying this oversight. We will remove the instruction block while preserving the required checklist questions."
+ },
+ "createdAt": "2026-08-02T02:00:22.489Z",
+ "modifiedAt": "2026-11-19T17:06:41.321Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=JNkNrErpHz",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lplvyrtk4x/notes/kwvw5yaasl.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/kwvw5yaasl.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "KWVW5yAASL",
+ "replyTo": "eFGZT9H5Cf",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer EBqc",
+ "content": {
+ "comment": "Thank you for the detailed response. I think the rebuttal addresses most of my main concerns. The node-to-anatomy consistency analysis provides useful evidence that the Memory Tree captures anatomy-associated organization, although the analysis is still relatively coarse and I would encourage adding visualizations if space permits. The fine-grained structural ablations and claim-inventory robustness studies are helpful and should be included in the revision. The runtime table also clarifies the practical cost, although it confirms that the method is still computationally heavy.\n\nI also appreciate the experiment showing that incorporating structural/semantic Detector signals into the final anomaly score does not improve performance, which justifies the use of pixel residuals.\n\nMy remaining concerns are mainly about the method complexity, the relatively high inference cost, and the lack of evidence beyond chest X-rays. Overall, the rebuttal substantially improves my confidence in the method, and I would be willing to raise my evaluation to borderline accept if these analyses and clarifications are incorporated into the paper."
+ },
+ "createdAt": "2026-08-03T02:23:51.295Z",
+ "modifiedAt": "2026-11-19T17:06:41.059Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=KWVW5yAASL",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lplvyrtk4x/notes/mnflj1za88.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/mnflj1za88.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "MnFlJ1ZA88",
+ "replyTo": "zwkxMC1skL",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer EY5N -- Part 1/2",
+ "comment": "**W1: Structural–semantic balance and robustness** \n\n**A1:** Thank you for this thoughtful suggestion. In our framework, structural and semantic normality jointly guide the refinement of the same normal reference. Accordingly, we do not introduce a manually tuned balance coefficient, as the two signals are not combined as a weighted sum of separate anomaly scores. Instead, the matched-tree feature constrains anatomical structure, while the normal-only claim-based caption constrains semantic content. The Detector evaluates them separately and returns branch-specific feedback, after which the Planner refines each condition accordingly. As shown in Table 2 of the original manuscript, combining both mechanisms consistently outperforms either one alone, demonstrating their complementary roles.\n\nRegarding relative robustness, Table 2 shows that Struct.-only achieves a small but consistent numerical advantage over Sem.-only across all three datasets and metrics. This suggests that structural feedback may provide a slightly stronger individual correction signal in the evaluated chest X-ray setting, possibly because matched-tree verification is directly grounded in anatomical representations and follows a deterministic update rule. However, given the small differences, we do not interpret this as evidence that structural feedback is generally more robust. We will add this clarification and discussion to the revised manuscript.\n\n\n----\n\n\n**W2: Generalization beyond chest X-rays**\n\n**A2:** Thank you for highlighting this important limitation. Our current experiments demonstrate cross-dataset robustness within chest radiography, rather than cross-modality or cross-anatomy generalization. ZhangLab, CheXpert, and COVIDx differ in data sources, pathology distributions, and task settings, providing evidence that the proposed method is robust across heterogeneous chest X-ray benchmarks. However, these results should not be interpreted as evidence of generalization to other medical imaging modalities.\n\nThe closed-loop collaboration paradigm is conceptually extensible to other modalities, although the current implementation is specialized for chest radiography. Extending it to another modality would require constructing modality-specific structural memory and semantic claims, as well as adapting the feature extractor and Reconstructor to the corresponding image characteristics. We will therefore clarify and restrict our empirical claims to chest radiography in the title, Abstract, Introduction, and Limitations. Evaluation on other anatomical regions and imaging modalities remains important future work.\n\n\n----\n\n\n\n**W3: Performance across anomaly types**\n\n**A3:** Thank you for this insightful suggestion. To investigate this issue, we conducted an additional pathology-stratified evaluation on CheXpert and COVIDx. ZhangLab was not further stratified because pneumonia is its only abnormal category.\n\nFor each CheXpert pathology, normal samples were treated as negatives, while samples with a positive label for the corresponding pathology were treated as positives. Samples belonging only to other abnormal categories were excluded from that subgroup. Because CheXpert is a multi-label dataset, samples with co-occurring positive findings were retained and could appear in multiple pathology-associated subgroups. Therefore, this evaluation measures performance on cases associated with each pathology rather than fully isolating the causal effect of an individual finding. \n\nTable 1. Pathology-stratified AUC-ROC results (%).\n\n| Dataset | Anomaly subtype | SimSID | DeCo-Diff | $\\mathrm{S}^{2}\\mathrm{Agent}$ |\n|---|---|---:|---:|---:|\n| CheXpert | Atelectasis | 78.71 | 79.92 | **81.62** |\n| | Cardiomegaly | 79.82 | 81.31 | **84.26** |\n| | Consolidation | 76.94 | 78.62 | **79.84** |\n| | Edema | 79.25 | 81.37 | **82.61** |\n| | Pleural Effusion | 82.14 | 82.68 | **84.73** |\n| COVIDx | Non-COVID Pneumonia | 82.64 | 88.47 | **90.35** |\n| | COVID-19 | 84.12 | 89.61 | **91.54** |\n\n\nThe stratified results show that $\\mathrm{S}^{2}\\mathrm{Agent}$ consistently outperforms the representative structure-aware and diffusion-based methods across all evaluated subgroups. Larger gains are observed for cardiomegaly and pleural effusion, which involve more noticeable changes in anatomical size, contour, or inter-structure relationships, consistent with the role of the Memory Tree and structural feedback. The gains are smaller but still consistent for consolidation and edema, suggesting that the method also remains effective for appearance-related abnormalities. Overall, $\\mathrm{S}^{2}\\mathrm{Agent}$ appears to benefit structural abnormalities more strongly while maintaining robust performance across diverse pathology types."
+ },
+ "createdAt": "2026-08-02T02:01:28.724Z",
+ "modifiedAt": "2026-11-19T17:06:41.201Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=MnFlJ1ZA88",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lplvyrtk4x/notes/ojscwxknsf.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/ojscwxknsf.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "OjsCwxKNSf",
+ "replyTo": "eFGZT9H5Cf",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer EBqc -- Part 3/3",
+ "comment": "**Q5 & W4.3: Incorporating Detector signals into anomaly scoring**\n\n**A5:** Thank you for raising this important question. Following the common reconstruction-based anomaly-detection paradigm [2,17,40], we use the pixel residual because it directly measures the spatial deviation of the input from the final verified normal reference.\n\nStructural and semantic discrepancies may arise either from input abnormalities or from an imperfect reconstruction. Therefore, using them directly for scoring may conflate input abnormality with reconstruction error.\n\nWe nevertheless evaluated their incorporation into the final score. Structural and semantic discrepancies were aggregated into image-level scores, normalized using only normal training samples, and combined with the pixel residual.\n\nTable 5. Incorporating Detector signals into final scoring (AUC-PR, %).\n\n| Final anomaly score | ZhangLab | CheXpert | COVIDx | Average |\n|:--|--:|--:|--:|--:|\n| Pixel residual | **93.27** | **79.16** | **91.26** | **87.90** |\n| Pixel + Structural | 92.84 | 78.52 | 90.71 | 87.36 |\n| Pixel + Semantic | 92.71 | 78.34 | 90.58 | 87.21 |\n| Pixel + Structural + Semantic | 92.38 | 77.96 | 90.19 | 86.84 |\n\nDirectly incorporating the Detector signals does not improve performance, supporting our functional separation: the Detector verifies and refines the normal reference, while the pixel residual measures the input's deviation from that verified reference.\n\n\n----\n\n\n**W3: Clarification of the method pipeline**\n\n**A6:** Thank you for highlighting this clarity issue. We clarify the procedure in execution order and distinguish fixed components from round-wise variables.\n\nDuring offline preparation, the Memory Tree and Reconstructor are trained on normal images, and the claim inventory is constructed from external reports. At inference, the Memory Tree topology, claim inventory, and input appearance prior $Q_x$ remain fixed. Only the sample-specific structural weights and semantic condition are updated across rounds.\n\n1. **Planning.** The input $x$ is retrieved through the Memory Tree to obtain the matched tree $T_x^{\\mathrm{pl}}$ and node matching rates $W_x^{\\mathrm{pl}}$. Weighted fusion produces the initial structural condition $F_x^{(0)}$. In parallel, BiomedCLIP selects visually supported normal claims to form the initial semantic condition $C^{(0)}$.\n\n2. **Reconstruction.** At round $t$, the Reconstructor takes the fixed appearance prior $Q_x$ and the current conditions $F_x^{(t)}$ and $C^{(t)}$ to generate $\\hat{x}^{(t)}$.\n\n3. **Verification and update.** The Detector retrieves the matched tree of $\\hat{x}^{(t)}$ and compares it node-wise with $T_x^{\\mathrm{pl}}$. The original matched tree remains fixed, while its node weights are updated according to structural consistency to produce $F_x^{(t+1)}$. In parallel, reconstructed claims are compared with $C^{(t)}$, and the Planner applies constrained revise, restore, or restrain operations to obtain $C^{(t+1)}$.\n\n4. **Termination.** The loop stops when neither branch returns an actionable discrepancy or when the four-round budget is reached; otherwise, the updated conditions are used in the next round.\n\nThe main settings are tree depth $4$, branching factor $2$, $16$ memory items per pool, at most $6$ retained claims, at most $4$ feedback rounds, and $100$ DDIM inversion and reverse-denoising steps. Claim selection and consistency checking use thresholds $\\tau_{\\mathrm{claim}}=0.25$ and $\\tau_{\\mathrm{struct}}=0.80$, respectively.\n\n\nThus, the inference path is:\n*retrieval and claim selection $\\rightarrow$ condition construction $\\rightarrow$ reconstruction $\\rightarrow$ dual-space verification $\\rightarrow$ structural reweighting and semantic refinement*.\n\n\n----\n\n\n**W4.2: Generalization beyond chest X-rays**\n\n**A7:** Thank you for highlighting this limitation. The current evidence supports generalization across chest X-ray datasets and pathology distributions, but not across anatomies or imaging modalities. We will therefore narrow the title, abstract, and conclusions to consistently frame the work as chest X-ray anomaly detection. Extending the framework to other modalities would require modality-specific normal structural memory, semantic claims, and reconstructor adaptation, which we will explicitly identify as future work.\n\n\n----\n\n\n**W5: Typos**\n\n**A8:**\nThank you for pointing out these typos. We will correct them and carefully proofread the manuscript for similar errors.\n\n\n----\n\n\n**Limitations: Robustness and model sensitivity, and computational cost**\n\n**A9:** Thank you for this suggestion. Runtime and memory cost, claim-inventory robustness, Memory Tree consistency, and the chest-X-ray-only scope are addressed in A1, A3, and A4. We will expand the limitations to acknowledge untested robustness across devices and demographic groups, and the risk that generative reconstruction may introduce artifacts or suppress clinically relevant abnormalities."
+ },
+ "createdAt": "2026-08-02T02:04:08.625Z",
+ "modifiedAt": "2026-11-19T17:06:41.313Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=OjsCwxKNSf",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lplvyrtk4x/notes/oxwi1yn5co.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/oxwi1yn5co.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "OxwI1YN5co",
+ "replyTo": "fvVeRmSf5F",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Area Chair nPjG",
+ "content": {
+ "comment": "To the authors: are you planning to submit a rebuttal with clarifications? My initial meta-review doesn’t guarantee acceptance"
+ },
+ "createdAt": "2026-07-31T19:57:24.302Z",
+ "modifiedAt": "2026-11-19T17:06:41.310Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=OxwI1YN5co",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lplvyrtk4x/notes/rrpoj6qnid.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/rrpoj6qnid.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "RrPOJ6qNid",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Area Chair nPjG",
+ "content": {
+ "comment": "The authors posted a detailed rebuttal on Aug 2 responding to your review (including [for EY5N: the requested case studies and memory-tree ablations] / [for q732: inference-cost, prompt details, and the multi-agent framing clarification]). Reviewer EBqc has already reviewed the response and updated their score to borderline accept.\n\nAs discussion time is limited, could you take a look at the authors' response and let us know whether it changes your assessment, along with an updated final justification/score if applicable?"
+ },
+ "createdAt": "2026-08-03T15:04:51.044Z",
+ "modifiedAt": "2026-11-19T17:06:41.310Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=RrPOJ6qNid",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lplvyrtk4x/notes/spentf5dpd.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/spentf5dpd.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "SpeNTF5dPd",
+ "replyTo": "eFGZT9H5Cf",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer EBqc -- Part 1/3",
+ "comment": "**Q1 & W1.1: Memory Tree node-to-anatomy correspondence**\n\n**A1:** We thank the reviewer for raising this important concern. Similarity-based prototype learning does not imply a one-to-one correspondence between every memory item and a named anatomical structure. Our claim is that the Memory Tree hierarchically organizes spatial normal prototypes, with many nodes exhibiting stable anatomy-associated responses across subjects.\n\nThis association can emerge because the encoder preserves a $16\\times16$ spatial feature map. Local features from corresponding anatomical regions across normal radiographs repeatedly retrieve and update similar prototypes through selective write-back. Nevertheless, some nodes may encode generic contours, intensity patterns, or textures. We therefore conducted an explicit node-to-anatomy correspondence analysis.\n\nWe evaluated 500 normal PA radiographs from CheXpert patients. Left-lung, right-lung, and cardiac-silhouette masks were obtained from CheXmask [1]. For each memory item, we identified its most responsive position among the 256 spatial locations and assigned it to the left lung, right lung, cardiac silhouette, or an explicit other/background category. Within each node, the region score was computed by similarity-weighted voting over its memory-item assignments and normalized by the corresponding mask area. The region with the highest score was treated as the node's dominant region for that image. A node was considered anatomy-associated when the same anatomical region was dominant in at least 70% of subjects. Thresholds from 60% to 90% were also evaluated.\n\nTable 1. Node-to-Anatomy Consistency (mean ± standard deviation, %).\n\n| Analysis setting | 60% | 70% | 80% | 90% |\n|---|---:|---:|---:|---:|\n| Random image-mask pairing | 29.8 ± 4.05 | 21.40 ± 3.62 | 14.73 ± 3.11 | 8.65 ± 2.24 |\n| Random tree topology | 47.82 ± 4.71 | 39.60 ± 4.37 | 31.24 ± 3.98 | 21.36 ± 3.45 |\n| Shuffled node-pool assignment | 42.63 ± 4.32 | 34.80 ± 3.94 | 27.15 ± 3.58 | 18.47 ± 3.02 |\n| **Learned Memory Tree** | **81.47 ± 2.43** | **75.16 ± 2.86** | **68.42 ± 3.11** | **57.83 ± 3.67** |\n\nBecause the rebuttal format does not permit figures, we use the table above to provide quantitative evidence of node-to-anatomy correspondence. Across five independently initialized Memory Trees, 75.16% of nodes exhibited stable anatomy-associated responses under the primary 70% criterion. The learned Memory Tree consistently outperforms all randomized controls, including under the stringent 90% criterion. Thus, we do not interpret every node as an explicitly labeled organ. Rather, these results demonstrate that the learned hierarchy produces cross-subject-consistent anatomy-associated organization, supporting its role as a normal structural prior. \n\n[1] CheXmask: A large-scale dataset of anatomical segmentation masks for multi-center chest X-ray images, Scientific Data 2024.\n\n\n----\n\n\n**Q2 & W2: Fine-grained ablations of the structural branch**\n\n**A2:** Thank you for this important comment. We conducted controlled ablations. In each comparison, only the investigated factor was changed, with all other settings fixed. Results are reported as mean ± standard deviation over five runs using AUC-PR (%).\n\nTable 2. Fine-grained ablations of the structural branch.\n\n| Component | Variant | ZhangLab | CheXpert | COVIDx |\n|:--|:--|--:|--:|--:|\n| Tree depth $L$ | 2 | 92.57 ± 0.25 | 77.90 ± 0.34 | 90.49 ± 0.29 |\n| | 3 | 92.99 ± 0.21 | 78.66 ± 0.30 | 90.95 ± 0.25 |\n| | 4 (default) | 93.27 ± 0.18 | 79.16 ± 0.27 | 91.26 ± 0.22 |\n| | 5 | 93.08 ± 0.20 | 78.87 ± 0.29 | 91.04 ± 0.24 |\n| Branching factor $b$ | 1 | 92.49 ± 0.24 | 77.77 ± 0.33 | 90.41 ± 0.28 |\n| | 2 (default) | 93.27 ± 0.18 | 79.16 ± 0.27 | 91.26 ± 0.22 |\n| | 3 | 93.06 ± 0.20 | 78.78 ± 0.30 | 91.03 ± 0.24 |\n| Tree topology | Random | 92.28 ± 0.27 | 77.40 ± 0.38 | 90.18 ± 0.31 |\n| | Data-driven (ours) | 93.27 ± 0.18 | 79.16 ± 0.27 | 91.26 ± 0.22 |\n| Memory write-back | Non-selective | 92.63 ± 0.23 | 78.12 ± 0.32 | 90.56 ± 0.27 |\n| | Selective (ours) | 93.27 ± 0.18 | 79.16 ± 0.27 | 91.26 ± 0.22 |\n| Matched-tree fusion | Uniform | 92.48 ± 0.24 | 77.95 ± 0.34 | 90.43 ± 0.28 |\n| | Matching-rate weighted (ours) | 93.27 ± 0.18 | 79.16 ± 0.27 | 91.26 ± 0.22 |\n| Node reweighting | Off | 92.85 ± 0.22 | 78.40 ± 0.31 | 90.80 ± 0.26 |\n| | On (ours) | 93.27 ± 0.18 | 79.16 ± 0.27 | 91.26 ± 0.22 |\n\nFor the depth and branching-factor studies, memory items were reallocated across nodes to keep the total memory capacity comparable. The moderate configuration ($L=4$, $b=2$) performs best, while further increasing tree complexity yields no additional benefit. \n\nThese results indicate that the gains do not arise merely from increased memory capacity. Instead, the learned topology, selective prototype updating, adaptive node aggregation, and feedback-based reweighting each contribute to the effectiveness of the structural branch."
+ },
+ "createdAt": "2026-08-02T02:10:52.729Z",
+ "modifiedAt": "2026-11-19T17:06:41.308Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=SpeNTF5dPd",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lplvyrtk4x/notes/udp9tff2a3.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/udp9tff2a3.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "uDp9tff2a3",
+ "replyTo": "KWVW5yAASL",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you for the positive assessment and thoughtful feedback. We appreciate that the additional analyses and clarifications have addressed most of your concerns and improved your confidence in our method. \n\nWe will incorporate these additional analyses and experiments into the revised manuscript. We also acknowledge the remaining limitations regarding method complexity, inference cost, and chest-X-ray-only validation. We will further clarify the method pipeline, discuss the computational overhead, and narrow the paper’s claims and framing to chest X-ray anomaly detection. \n\nThank you again for your constructive suggestions."
+ },
+ "createdAt": "2026-08-04T02:25:51.013Z",
+ "modifiedAt": "2026-11-19T17:06:41.212Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=uDp9tff2a3",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lplvyrtk4x/notes/xfrnoyigwh.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/xfrnoyigwh.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "XfRNoyiGwh",
+ "replyTo": "R45X6M8Cwa",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer q732 -- Part 1/2",
+ "comment": "**Q1: Closed-loop inference overhead**\n\n**A1:** Thank you for raising this important question. We profiled the current implementation on a single NVIDIA A100 GPU. The reported end-to-end latency covers the complete inference pipeline from a preprocessed input image to the final anomaly score, including structural retrieval, claim selection, reconstruction, dual-space verification, semantic refinement when triggered, and all executed refinement rounds. One-time model loading and CUDA initialization are excluded.\n\nTable 1. Inference overhead of closed-loop refinement.\n\n| Setting | Avg. rounds | Time (s/image) | Peak GPU memory (GB) |\n|:--|--:|--:|--:|\n| Single-pass inference | 1.00 | 9.7 | 18.7 |\n| Closed loop with early stopping | 1.91 | 18.5 | 19.8 |\n| Fixed four-round inference | 4.00 | 38.8 | 20.0 |\n\nSingle-pass inference performs one reconstruction without subsequent feedback-based refinement, whereas fixed four-round inference always executes four reconstruction–verification cycles. With early stopping, the framework executes 1.91 rounds on average, requiring 18.5 s/image compared with 38.8 s/image for fixed four-round execution.\n\nThe increase in peak GPU memory is modest because the refinement rounds are executed sequentially rather than in parallel. These results indicate that early stopping provides a practical compromise between refinement effectiveness and inference efficiency.\n\n\n----\n\n\n**Q2: LLM and prompt details**\n\n**A2:** Thank you for pointing out this important issue. We use Qwen2.5-7B-Instruct as the LLM-based semantic modifier in the Planner. The model is used without task-specific fine-tuning, and its parameters remain frozen throughout inference.\n\nWe use the same prompt template across all datasets and refinement rounds. At each round, the LLM receives only the current semantic caption and the semantic feedback generated by the Detector. The complete interaction history is not included, which avoids accumulating irrelevant context and ensures that each refinement is directly grounded in the latest detected discrepancy. We use deterministic greedy decoding with a maximum output length of 256 new tokens.\n\nThe exact prompts are provided below.\n\n1. System prompt\n\nYou are a semantic-constraint modifier for normality-oriented chest X-ray reconstruction. Minimally revise the current caption according to the Detector feedback using only the following operations:\n\n- Revise: Correct descriptions identified as inconsistent by the feedback.\n- Restore: Add a missing normal observation only when explicitly requested by the feedback.\n- Restrain: Remove unsupported, pathological, diagnostic, or uncertain content.\n\nPreserve all unaffected normal observations. Do not add information unsupported by the current caption or Detector feedback. Keep the caption concise and normal-only. Return only the refined caption without explanations or additional formatting.\n\n2. User prompt\n\nCurrent caption: \n{CURRENT_CAPTION}\n\nDetector feedback: \n{DETECTOR_FEEDBACK}\n\nReturn only the refined caption.\n\n\n----\n\n\n**Q3 & W2: Generalization beyond chest X-rays**\n\n**A3:** Thank you for highlighting this scope issue. We agree that the current experiments demonstrate cross-dataset robustness within chest radiographs, but do not establish generalization to non-chest modalities. The current Memory Tree, claim inventory, and Reconstructor are specifically instantiated for chest X-rays, although the overall closed-loop framework could be adapted to other modalities with modality-specific structural, semantic, and reconstruction components. We will therefore narrow our claims to chest X-ray anomaly detection and revise the title, abstract, introduction, and conclusion accordingly. Cross-modality evaluation will be left for future work.\n\n\n----\n\n\n**Q4 & W4: Pixel-level anomaly localization**\n\n**A4:** Thank you for raising this point. Our current study focuses on image-level anomaly detection. ZhangLab and COVIDx provide only image-level labels, while pixel-level annotations are available only for a limited subset of CheXpert through the separate CheXlocalize resource. Therefore, a consistent pixel-level evaluation under the same protocol across the three benchmarks is not currently feasible.\n\nIn addition, the proposed training objective and anomaly scoring strategy are designed for image-level detection rather than localization. Although the pixel-wise reconstruction residual can provide qualitative spatial cues, the current model is not explicitly optimized or calibrated for pixel-level anomaly localization. We therefore do not claim that the present results establish improved localization performance. Figure 2 only provides qualitative evidence that closed-loop refinement can reduce spurious residuals in normal regions while preserving abnormal-to-normal correction. We will clarify the scope of the current evaluation and explicitly identify systematic pixel-level localization as an important direction for future work."
+ },
+ "createdAt": "2026-08-02T02:13:22.848Z",
+ "modifiedAt": "2026-11-19T17:06:41.313Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=XfRNoyiGwh",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lplvyrtk4x/notes/yjnw4bpasm.json added

+++ b/reviews/openreview/lplvyrtk4x/notes/yjnw4bpasm.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "YJNw4bpASM",
+ "replyTo": "fvVeRmSf5F",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank Area Chair nPjG for the thorough assessment and valuable follow-up. Below, we provide additional clarifications and results addressing the concerns raised.\n\n\n----\n\n\n**Q1: Standard deviations and significance tests**\n\n\n**A1:** Tables 1 and 2 report mean results over five independent runs. Owing to space constraints, we report the mean ± standard deviation for representative strong baselines and key ablations below. Complete statistics for all baselines and ablation variants will be included in the final version.\n\nTable R1. Comparison with representative strong baselines.\n\n| Methods | Zhang AUC-PR | Zhang AUC-ROC | CheXpert AUC-PR | CheXpert AUC-ROC | COVIDx AUC-PR | COVIDx AUC-ROC |\n|:--|--:|--:|--:|--:|--:|--:|\n| SimSID | 89.64 ± 0.28 | 91.10 ± 0.24 | 73.17 ± 0.41 | 79.67 ± 0.36 | 90.84 ± 0.33 | 83.47 ± 0.29 |\n| PDD | 92.43 ± 0.22 | 94.02 ± 0.19 | 72.34 ± 0.34 | 79.13 ± 0.30 | 89.14 ± 0.28 | 86.24 ± 0.25 |\n| DeCo-Diff | 90.23 ± 0.24 | 91.94 ± 0.21 | 76.83 ± 0.35 | 81.19 ± 0.31 | 88.43 ± 0.29 | 89.02 ± 0.26 |\n| **S$^2$Agent** | **93.27 ± 0.18** | **94.81 ± 0.16** | **79.16 ± 0.27** | **82.34 ± 0.24** | **91.26 ± 0.22** | **90.93 ± 0.20** |\n\nTable R2. Key ablation results (AUC-PR, %).\n\n| Aspect | Variant | ZhangLab | CheXpert | COVIDx |\n|:--|:--|--:|--:|--:|\n| Structural Constraint | *Flat* | 91.86 ± 0.28 | 76.64 ± 0.39 | 89.71 ± 0.33 |\n| | *Tree* | 93.27 ± 0.18 | 79.16 ± 0.27 | 91.26 ± 0.22 |\n| Closed-loop Feedback | *Struct.-only* | 92.43 ± 0.23 | 78.12 ± 0.32 | 90.38 ± 0.27 |\n| | *Sem.-only* | 92.29 ± 0.25 | 77.91 ± 0.35 | 90.19 ± 0.29 |\n| | *Both* | 93.27 ± 0.18 | 79.16 ± 0.27 | 91.26 ± 0.22 |\n\n\nAll compared methods were evaluated using the same five data splits and random seeds, enabling run-wise two-sided paired $t$-tests. For the baseline comparisons, S$^2$Agent achieves statistically significant improvements on all reported metrics, except against SimSID on COVIDx AUC-PR, where it still achieves a numerical gain. For the ablations, *Tree* significantly outperforms *Flat*, while *Both* significantly outperforms both single-feedback variants ($p<0.05$). \n\n\n----\n\n\n**Q2: Claim-inventory source overlap**\n\n**A2:** We acknowledge that the original no-overlap statement was inaccurate because CheXpert Plus augments CheXpert with radiology reports, and we will correct it.\n\n\nThe CheXpert Plus reports were used only for offline corpus-level extraction of canonical normal-anatomy statements. The resulting inventory contains 122 normalized generic claims and retains no image identifiers, labels, patient information, or sample-specific report content. During evaluation, no benchmark report is retrieved or matched to an individual test image.\n\n\nTo directly assess whether this source overlap affects performance, we independently rebuilt an inventory of the same size using only ReXGradient-160K and reran all evaluations (`Q3&W1.2-A3 to Reviewer EBqc`). The results remained nearly unchanged, indicating that the reported gains are not materially attributable to the use of CheXpert Plus reports.\n\n\n----\n\n**Q3: VLM self-reference and sensitivity**\n\n\n**A3:** Using the same VLM in the Planner and Detector may introduce correlated model-specific preferences. However, both modules operate over a fixed inventory of 122 canonical normal claims, and the Detector independently re-grounds the reconstructed image rather than reusing the Planner’s matching scores. This constrained claim space limits the potential self-referential effect.\n\nWe further replaced BiomedCLIP [42] with MedCLIP (EMNLP 2022) and evaluated both same-VLM and cross-VLM settings. \n\nTable R3. VLM robustness (AUC-PR, %).\n\n| Planner VLM | Detector VLM | ZhangLab | CheXpert | COVIDx |\n|:--|:--|--:|--:|--:|\n| BiomedCLIP | BiomedCLIP | 93.27 ± 0.18 | 79.16 ± 0.27 | 91.26 ± 0.22 |\n| MedCLIP | MedCLIP | 93.06 ± 0.21 | 78.91 ± 0.34 | 91.02 ± 0.20 |\n| BiomedCLIP | MedCLIP | 92.91 ± 0.22 | 78.73 ± 0.32 | 90.86 ± 0.55 |\n| MedCLIP | BiomedCLIP | 92.84 ± 0.47 | 78.65 ± 0.62 | 90.78 ± 0.26 |\n\nPerformance remains consistent across VLM replacements and cross-VLM settings. These results indicate limited sensitivity to VLM choice and suggest that the semantic refinement does not primarily depend on shared BiomedCLIP-specific preferences.\n\n\n----\n\n\n**Q4: Chest-X-ray-specific scope**\n\n\n**A4:** We will narrow the title and overall framing to chest X-ray anomaly detection and explicitly clarify that the current claim inventory, implementation, and empirical validation are chest-radiograph-specific, as detailed in the responses (`W2-A2 to Reviewer EY5N`; `W4.2-A7 to Reviewer EBqc`; `Q3&W2-A3 to Reviewer q732`).\n\n----\n\n\n**Q5: Computational cost**\n\n**A5:** We reported the computational cost in our reviewer responses (`Q4&W4.1-A4 to Reviewer EBqc`; `Q1-A1 to Reviewer q732`). With early stopping, the closed loop averages 1.91 rounds and reduces latency by 52.3% compared with fixed four-round inference."
+ },
+ "createdAt": "2026-08-04T02:21:22.662Z",
+ "modifiedAt": "2026-11-19T17:06:41.203Z",
+ "url": "https://openreview.net/forum?id=LplVYRTK4x&noteId=YJNw4bpASM",
+ "license": "CC-BY-4.0"
+}