potentialpaper

Delay-Embedded Representations for Robust Saccade Classification in Noisy Oculographic Signals

Import NeurIPS 2026 submission hpVPOORw3w: 5 notes

@openreview[bot] · 2026-11-22 17:58 UTC · 5dc7a60b35c4

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,23 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "hpVPOORw3w"
+ }
+ ],
+ "title": "Delay-Embedded Representations for Robust Saccade Classification in Noisy Oculographic Signals",
+ "authors": [
+ "Vladimir",
+ "Artem Badarin",
+ "Alexander E. Hramov"
+ ],
+ "abstract": "We introduce ACMA (Delay-Augmented Clustering and Model Approximation), a noise-robust pipeline for saccade detection in oculographic signals that couples delay-embedded clustering with physiologically grounded parametric refinement. Existing detectors face a recurring trade-off: velocity-thresholding methods are simple and interpretable but degrade catastrophically as recording noise grows, adaptive event-based detectors recover part of this gap at moderate noise but lose reliability at high noise, and recent deep models are sensitive to noise distributions unseen during training. ACMA addresses this trade-off in two stages. First, a sliding-window two-cluster decomposition with time-delay embedding identifies candidate saccades while remaining stable across noise regimes. Second, a parametric saccade waveform constrained by priors on amplitude, duration, and the saccadic main sequence validates and characterizes each event. We evaluate ACMA on a saccade-detection benchmark spanning a wide range of noise levels and nine representative baselines, including a leading deep-learning detector (U'n'Eye), adaptive methods (NH, REMoDNaV, Engbert), clustering-based I2MC, and classical velocity-thresholding methods (IVT, IVVT, IDT, IDVT). ACMA delivers consistent F1 gains in moderate-to-high noise regimes, where competing detectors degrade sharply, while additionally returning physically meaningful per-event metrics (amplitude, duration, peak velocity) for downstream neurological assessment, fatigue monitoring, and brain-computer interface applications.",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/hpvpoorw3w/forms.json added

+++ b/reviews/openreview/hpvpoorw3w/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/hpvpoorw3w/notes/4mofnntdix.json added

+++ b/reviews/openreview/hpvpoorw3w/notes/4mofnntdix.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "4MofnNtdIx",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "ACMA is an unsupervised two-stage saccade detector: delay embedding plus PCA/k-means to find candidate transitions, then parametric waveform fitting to reject false positives and recover kinematics. Scores are split (borderline reject, borderline accept, reject), but the reviewers agree the problem is well motivated and the method interpretable, while novelty, ablations, and the realism of the evaluation are the weak points.\n\nThe rebuttal should take into account the following points\n\n1) The three reviewers believe that the module-level ablations are missing (gKuk, TUdm, VJXP). Since the contribution is mainly the integration of established components, please isolate the contribution of delay embedding (e.g. Nd=0), PCA voting, and the parametric-fitting/R^2 stage, reporting F1, kappa, and timing errors. Answer gKuk's question of what delay embedding adds over plain PCA/clustering directly. \n\n2) Testing beyond idealized additive noise would be helpful (VJXP, TUdm). The pink-noise sweep omits structured artifacts (head motion, drift, correlated axes, dropout). Please show conclusions hold on more realistic data, ideally a small annotated wearable/clinical subset.\n\n3) Characterize native noise and simulator fairness (VJXP). Quantify the native noise of the real recordings and clarify added-only vs total RMS, and address that the simulator shares ACMA's parametric model.\n\nConvincing responses to items 1 and 2 would be an important consideration as we discuss the paper.",
+ "final_justification": "The authors delivered the evidence requested. They also openly acknowledged that the simulator favours their method and narrowed their claims accordingly. All three reviewers responded positively, with two raising their scores and the third indicating they would do the same. The contribution remains largely an integration of established components, but the method is well motivated, interpretable, and empirically solid. The new material must appear in the camera-ready version."
+ },
+ "createdAt": "2026-09-24T11:28:30.432Z",
+ "modifiedAt": "2026-11-18T14:59:54.282Z",
+ "url": "https://openreview.net/forum?id=hpVPOORw3w&noteId=4MofnNtdIx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/hpvpoorw3w/notes/6ytkuo5ros.json added

+++ b/reviews/openreview/hpvpoorw3w/notes/6ytkuo5ros.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "6yTkUo5RoS",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer VJXP",
+ "content": {
+ "summary": "This paper presents ACMA, an unsupervised method for detecting saccades in noisy eye-movement signals. The key idea is to first use short-term temporal context to identify candidate transitions between fixation states, rather than relying on noisy point-wise velocity estimates. Each candidate is then verified by fitting a physiologically plausible saccade waveform, which helps reject false detections and refine the event onset and offset. The method also estimates interpretable properties such as amplitude, duration, direction, and peak velocity. The authors evaluate ACMA on two real eye-tracking datasets and one simulated dataset under progressively stronger synthetic noise, and compare it against classical, adaptive, clustering-based, and deep-learning baselines.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "### Strengths\n\n- **[Clarity / Motivation] Important practical problem.** The paper clearly motivates robust saccade detection for noisy eye-tracking, EOG, clinical, and wearable settings.\n\n- **[Method / Interpretability] Simple and interpretable design.** The two-stage pipeline cleanly separates candidate detection from physiological verification, while remaining unsupervised and producing meaningful event-level measurements.\n\n### Weaknesses\n\n- **[Originality] Novelty is mainly in the integration.** Delay embedding, PCA-based clustering, and parametric saccade fitting are established components; the main contribution is combining them into a single pipeline.\n\n- **[Quality / Noise model] The corruption model is simplified.** Independent synthetic pink noise does not capture structured artifacts such as head motion, calibration drift, correlated axis noise, or device-specific tracking failures.\n\n- **[Quality / Noise calibration] Native noise is not characterized.** The real recordings may already contain noise, but only the added RMS noise is reported, making the effective total noise and cross-dataset comparisons difficult to interpret.\n\n- **[Quality / Simulator design] The simulated benchmark may favor the method.** The simulator and ACMA’s refinement stage rely on the same parametric saccade model, which may partly explain the strong results on synthetic data.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 2,
+ "questions": "1. Can the authors quantify the native noise level of the Andersson and EyeLink recordings before adding synthetic corruption, and clarify whether the reported RMS values refer only to the added noise or to the effective total noise?\n\n2. How well does ACMA generalize to more realistic noise and artifacts, such as head motion, calibration drift, correlated horizontal–vertical noise, and device-specific tracking failures, rather than independent synthetic pink noise alone?\n\n3. Could the method be evaluated on a naturalistic wearable gaze dataset such as Meta’s Aria Everyday Activities, potentially using a small manually annotated subset? How would ACMA handle head motion, calibration errors, and the lack of expert saccade/fixation labels?",
+ "limitations": "The authors discuss several relevant limitations, including the lack of explicit PSO modeling, limited validation across populations and devices, the need to validate recovered kinematic parameters, and dependence on a few user-defined hyperparameters. However, the limitations section does not sufficiently address the real-world applicability of ACMA to wearable eye-tracking systems, where head motion, calibration drift, device-specific artifacts, and unknown native noise levels may be important. These points should be acknowledged more explicitly.",
+ "rating": 4,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "I do not see any formatting concerns.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The rebuttal and discussion substantially addressed my main concerns about whether the evaluation supports the paper’s practical claims. Although some limitations remain, I now view them as scope limitations rather than fundamental weaknesses, so I am updating my score to borderline accept."
+ },
+ "createdAt": "2026-07-20T22:38:48.908Z",
+ "modifiedAt": "2026-11-18T13:45:34.721Z",
+ "url": "https://openreview.net/forum?id=hpVPOORw3w&noteId=6yTkUo5RoS",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/hpvpoorw3w/notes/hqohgzqw9n.json added

+++ b/reviews/openreview/hpvpoorw3w/notes/hqohgzqw9n.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "hQoHGzqw9N",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer gKuk",
+ "content": {
+ "summary": "This work intoduces an unsupervised method for detecting saccades in eye movement tracking data. The work first creates a delay embedding, then dimensionality reduces it and clusters it to find candidate saccades. It then fits a parametric model of a saccade to help reduce false positives. and compares this to a wide array of baselines on several datasets.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "- The paper does a good job of setting up why the problem is important and making improvements in this domain is likely to have impact on the medical communiuty\n- The paper does a good job running their method on real world datasets\n- The paper explains their method thoroughly\n- The paper has a reasonable comparison to other baselines in the field\n- Nice use of an unsupervised method\n- FItting a parametric curve to the data can recover physically useful quantities which is nice\n\n\n- The work does not include an ablation study of the main components of the idea, Delay embeddings, PCA, parametric fitting and filtering. It would be useful to understand how each of these contribute to the models performance",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 2,
+ "questions": "- Why is the delay embedding important here, what does it provide that a regular clustering and PCA of the points do not",
+ "limitations": "yes",
+ "rating": 5,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "no",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "Good work and a rebuttal that answered my key questions"
+ },
+ "createdAt": "2026-06-26T21:21:08.795Z",
+ "modifiedAt": "2026-11-18T13:45:36.098Z",
+ "url": "https://openreview.net/forum?id=hpVPOORw3w&noteId=hQoHGzqw9N",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/hpvpoorw3w/notes/kkobivvfyu.json added

+++ b/reviews/openreview/hpvpoorw3w/notes/kkobivvfyu.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "KkObivvfyu",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair 8uZA",
+ "content": {
+ "metareview": "ACMA is an unsupervised two-stage saccade detector: delay embedding plus PCA/k-means to find candidate transitions, then parametric waveform fitting to reject false positives and recover kinematics. Scores are split (borderline reject, borderline accept, reject), but the reviewers agree the problem is well motivated and the method interpretable, while novelty, ablations, and the realism of the evaluation are the weak points.\n\nThe rebuttal should take into account the following points\n\n1) The three reviewers believe that the module-level ablations are missing (gKuk, TUdm, VJXP). Since the contribution is mainly the integration of established components, please isolate the contribution of delay embedding (e.g. Nd=0), PCA voting, and the parametric-fitting/R^2 stage, reporting F1, kappa, and timing errors. Answer gKuk's question of what delay embedding adds over plain PCA/clustering directly. \n\n2) Testing beyond idealized additive noise would be helpful (VJXP, TUdm). The pink-noise sweep omits structured artifacts (head motion, drift, correlated axes, dropout). Please show conclusions hold on more realistic data, ideally a small annotated wearable/clinical subset.\n\n3) Characterize native noise and simulator fairness (VJXP). Quantify the native noise of the real recordings and clarify added-only vs total RMS, and address that the simulator shares ACMA's parametric model.\n\nConvincing responses to items 1 and 2 would be an important consideration as we discuss the paper."
+ },
+ "createdAt": "2026-07-21T17:15:37.867Z",
+ "modifiedAt": "2026-11-18T15:25:52.932Z",
+ "url": "https://openreview.net/forum?id=hpVPOORw3w&noteId=KkObivvfyu",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/hpvpoorw3w/notes/mixjjq9wmc.json added

+++ b/reviews/openreview/hpvpoorw3w/notes/mixjjq9wmc.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "mixjjq9WmC",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer TUdm",
+ "content": {
+ "summary": "This paper presents ACMA, an unsupervised two-stage method for saccade detection in noisy oculographic signals. The method first applies short-time delay embedding to the gaze signal, then uses PCA and k-means within overlapping windows to identify candidate transitions. These candidates are further validated by fitting a physiologically constrained saccade waveform and applying an R² threshold. The final output includes SAC/FIX/BLINK labels and event-level kinematic parameters. Experiments on two real expert-annotated datasets and one simulated dataset with multiple levels of added pink noise compare ACMA against nine baselines. The results show that ACMA achieves the best overall F1, Cohen’s kappa, and high-noise performance, with particularly improved robustness for saccade detection.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths \n1. The problem is practical and clearly defined. Saccade detection under noisy conditions is important for wearable EOG, clinical applications, and mobile eye-movement analysis. \n2. The method is intuitive and interpretable. Delay embedding adds short-term dynamic information, while parametric waveform fitting provides physically interpretable outputs such as amplitude, duration, and peak velocity. \n3. Its unsupervised and modality-agnostic nature is a strength, making it easier to transfer to new devices or noise conditions than supervised deep models. \n4. The experimental comparison is fairly comprehensive, with nine baselines spanning classical thresholding, adaptive/event-based methods, clustering approaches, and deep learning. \n\nWeaknesses \n1. The algorithmic novelty is mostly an engineering combination. Delay embedding, k-means transition detection, PCA voting, and saccade waveform fitting all have precedents; the main contribution lies in their integration and evaluation. \n2. The paper lacks module-level ablations. It does not sufficiently quantify the individual contributions of delay augmentation, PCA projection, explained-variance voting, parametric fitting, and the R² threshold. \n3. The noise model is somewhat idealized. A pink-noise RMS sweep does not cover non-additive artifacts, drift, occlusion, calibration error, and device-specific dropout common in real wearable or clinical scenarios. \n4. External real-world validation remains limited. Two expert-annotated datasets plus one simulator are not enough to cover infants, clinical populations, and consumer-grade EOG. \n5. The kinematic parameters are not yet validated. Although the paper claims to return amplitude, duration, and peak velocity, these metrics are not systematically compared against expert annotations or simulator ground truth. \n6. PSOs are not modeled, which may affect offset estimation and event labeling.",
+ "quality": 2,
+ "clarity": 3,
+ "significance": 2,
+ "originality": 3,
+ "questions": "1. How much does delay embedding itself contribute? If Nd=0 is used while retaining PCA voting and parametric fitting, how much does performance drop? \n2. How much does parametric waveform fitting contribute? If only the candidate mask from delay-augmented clustering is used, what are the resulting F1, kappa, and timing errors? \n3. Are the R² threshold of 0.6, window length of 200 ms, hop size of 20 ms, and Nd=3 optimal across all sampling rates and datasets? Was any sensitivity analysis performed? \n4. On real wearable EOG data or clinical patient data, do the conclusions from the pink-noise benchmark still hold? \n5. How does ACMA classify microsaccades, smooth pursuit, glissades, and post-saccadic oscillations? \n6. Is the event-matching IoU threshold of 0.25 too lenient? Under stricter thresholds, does the timing advantage still hold?",
+ "limitations": "1. The current method outputs only three classes: SAC, FIX, and BLINK. It cannot explicitly identify PSOs, smooth pursuit, or other eye-movement events. \n2. The benchmark is mainly based on artificially added noise, which cannot fully represent the complex artifacts found in real mobile-device and clinical recordings. \n3. Hyperparameters still need to be set manually, and cross-device deployment may require retuning. \n4. The accuracy of the kinematic parameters lacks independent validation. \n5. Its ability to detect very short, low-amplitude saccades or microsaccades remains unclear. \n6. The number of real datasets is small, and inter-rater variability among expert annotations is not sufficiently discussed.",
+ "rating": 3,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "None",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "My suggestion is Borderline reject."
+ },
+ "createdAt": "2026-06-12T03:30:42.869Z",
+ "modifiedAt": "2026-11-18T13:45:37.464Z",
+ "url": "https://openreview.net/forum?id=hpVPOORw3w&noteId=mixjjq9WmC",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/hpvpoorw3w/submission.json added

+++ b/reviews/openreview/hpvpoorw3w/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "hpVPOORw3w",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 34210,
+ "url": "https://openreview.net/forum?id=hpVPOORw3w",
+ "license": "CC-BY-4.0"
+}

versions/v_h25w7a38.json added

+++ b/versions/v_h25w7a38.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-05-05",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 34210,
+ "url": "https://openreview.net/forum?id=hpVPOORw3w",
+ "reviews": "openreview/hpvpoorw3w",
+ "evidence": [
+ "https://openreview.net/forum?id=hpVPOORw3w"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=hpVPOORw3w",
+ "evidence": [
+ "https://openreview.net/forum?id=hpVPOORw3w"
+ ]
+}