Import NeurIPS 2026 submission Txi4PjNfS3: 5 notes
@openreview[bot] · 2026-11-22 17:57 UTC · 15e25a282861
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,22 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "Txi4PjNfS3"+ }+ ],+ "title": "Parametric Meets Non-parametric: Bridging Dual Prediction Spaces for Semi-supervised Medical Image Segmentation",+ "authors": [+ "Zenggui Chen",+ "Jianwei Ma"+ ],+ "abstract": "Semi-supervised medical image segmentation leverages abundant unlabeled data to reduce the reliance on costly dense annotations, yet its dominant pseudo-labeling paradigm suffers from inevitable prediction noise, especially under scarce supervision. In this work, we observe that parametric network predictions and non-parametric prototype-based predictions exhibit complementary behaviors under pseudo-label noise: the former offers high expressiveness in capturing local structures but is sensitive to erroneous supervision, while the latter provides stable semantic guidance by aggregating class-level statistics but may lack spatial precision. Motivated by this observation, we propose a simple yet effective complementary learning framework that jointly exploits the parametric prediction space and the non-parametric prototype space for semi-supervised segmentation. Specifically, we introduce a confidence-aware selection mechanism that identifies reliable pixels from either prediction space, a prototype entropy minimization objective that sharpens the non-parametric semantic anchors, and a dual-space semantic alignment objective that encourages mutual enhancement between the two spaces. The unified objective enables reliability-aware mutual enhancement, where each space guides the other when confident and noisy alignment is suppressed when both are uncertain. Extensive experiments on multiple medical image segmentation benchmarks demonstrate that our method consistently outperforms existing approaches under various label-scarce settings.",+ "year": 2026,+ "venue": "NeurIPS 2026",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/txi4pjnfs3/forms.json added
+++ b/reviews/openreview/txi4pjnfs3/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/txi4pjnfs3/notes/0sryd9dy7j.json added
+++ b/reviews/openreview/txi4pjnfs3/notes/0sryd9dy7j.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "0sRYd9dy7J",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer MKBo",+ "content": {+ "summary": "This paper proposes a semi-supervised medical image segmentation framework that combines parametric network predictions with non-parametric prototype-based predictions. The main idea is that the parametric branch provides spatially precise dense predictions but is sensitive to noisy pseudo-labels, while the prototype branch offers more stable semantic guidance through class-level aggregation. The method uses confidence-aware pixel selection, prototype entropy minimization, and KL-based dual-space alignment to let the two prediction spaces complement each other. Experiments on ACDC, Left Atrium, and Pancreas-NIH show consistent improvements over recent semi-supervised segmentation methods.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "### Strengths\n1. The paper addresses an important problem in semi-supervised medical image segmentation and proposes a novel dual-space complementary learning perspective. Instead of using prototypes merely as auxiliary representations, it treats non-parametric prototype prediction as a complementary prediction space to the conventional parametric segmentation head. This design is interesting and well motivated, since the parametric branch can provide detailed dense predictions while the prototype branch offers more stable class-level semantic guidance under noisy pseudo-labels.\n\n2. The proposed framework is technically clean and practical. It combines confidence-aware selection, prototype entropy minimization, and dual-space semantic alignment without introducing a heavy architecture, making it easy to integrate into existing segmentation pipelines. The experimental evaluation is also strong, covering both 2D and 3D medical segmentation benchmarks and showing consistent improvements over recent semi-supervised baselines under different label ratios. The ablation studies provide solid support for the proposed design. The component-wise ablations show the effectiveness of each module, and Figure 4 is especially useful because it goes beyond final performance numbers. This analysis gives more direct evidence that the proposed method improves the semantic structure of the embedding space and supports the claim that parametric and prototype-based predictions are complementary.\n\n### Weaknesses\n1. One weakness is that some implementation details are not fully specified. For example, it is unclear whether gradients are stopped in either branch during semantic alignment, how prototypes are initialized and normalized, and how the EMA prototype update handles classes that are absent from a mini-batch. These details are important for reproducibility and for understanding the exact optimization behavior of the proposed dual-space learning scheme.\n\n2. Another concern is that the confidence-aware selection strategy may depend on threshold choices. The paper uses different confidence thresholds for 2D and 3D datasets, but provides limited discussion on how these values are selected. A sensitivity analysis or statistics on the selected pixel ratio during training would make the method more transparent.\n\n3. Finally, although the empirical results are strong, the paper could further improve its reliability by reporting variance over multiple random seeds or different labeled-data splits. Semi-supervised medical segmentation under very limited labels can be sensitive to initialization and data selection, so such results would help confirm the stability of the observed gains. \n\nOverall, the paper presents a clean and practically useful framework with convincing empirical performance. The main weaknesses are some missing implementation details, and the need for stronger analysis to isolate why the prototype branch improves semi-supervised learning beyond existing auxiliary-branch or prototype-based methods.",+ "quality": 3,+ "clarity": 4,+ "significance": 3,+ "originality": 4,+ "questions": "1. The paper states that the KL-based alignment enables mutual enhancement because gradients flow through both the prototype prediction and the parametric prediction. However, it is not clear whether either branch is detached in the actual implementation. If no detachment is used, could the authors explain how the method avoids unstable mutual confirmation or degenerate sharpening, especially when prototype entropy minimization is also applied?\n\n2. The current ablation validates DSA, PEM, and confidence selection, but it does not fully show whether the gain comes specifically from prototype-based non-parametric prediction. A useful comparison would be an auxiliary learnable segmentation head with a similar alignment objective and confidence selection. This would help determine whether the prototype mechanism is essential or whether the improvement mainly comes from multi-branch consistency.\n\n3. Equation (2) defines prototype updates using ground-truth labels only. Are prototypes also updated using confident pseudo-labels on unlabeled data during training? If yes, please add this to the formulation; if no, could the authors discuss whether including pseudo-labeled embeddings in the EMA update would help or hurt, given the noise concerns? An ablation on this choice would be informative.\n\n4. Since the unified loss reduces to \\(H(r_i, s_i)\\), a natural baseline is to directly use the prototype-branch prediction as a soft pseudo-label for the parametric branch (i.e., no DSA/PEM decomposition, no confidence gating, just CE with \\(r_i\\) as target). How does this baseline compare to the full method? This would help isolate the contribution of confidence gating and entropy sharpening beyond the prototype-guided supervision itself.\n\nIf the authors can clarify or address the above questions, it would improve my evaluation of the paper. These analyses would make the empirical evidence more convincing and provide stronger support for the effectiveness of the proposed dual-space complementary learning framework.",+ "limitations": "See Section Strengths And Weaknesses",+ "rating": 5,+ "confidence": 5,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "N/A",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The authors have carefully addressed my main concerns through additional clarification and experiments.\n\nOverall, I find the rebuttal convincing and believe the paper is solid with a clear and useful contribution. I therefore raise my rating to 5."+ },+ "createdAt": "2026-06-26T12:00:31.471Z",+ "modifiedAt": "2026-11-18T13:45:46.121Z",+ "url": "https://openreview.net/forum?id=Txi4PjNfS3¬eId=0sRYd9dy7J",+ "license": "CC-BY-4.0"+}
reviews/openreview/txi4pjnfs3/notes/8xkqazhoen.json added
+++ b/reviews/openreview/txi4pjnfs3/notes/8xkqazhoen.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "8XkqAZhoeN",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair nbqs",+ "content": {+ "metareview": "The submission addresses semi-supervised image segmentation using a combination of parametric network predictions with non-parametric prototype-based predictions. This is a sensible approach, though not one that is particularly novel. In particular, Reviewers 8Xit and ojW2 both raise extensive concerns about the relationship to previous work. These concerns need to be addressed in a rebuttal. An additional concern is about the size of the effect of the method, with reviewers pointing out that the improvements over strong baselines are small."+ },+ "createdAt": "2026-07-23T09:48:18.266Z",+ "modifiedAt": "2026-11-18T15:26:02.691Z",+ "url": "https://openreview.net/forum?id=Txi4PjNfS3¬eId=8XkqAZhoeN",+ "license": "CC-BY-4.0"+}
reviews/openreview/txi4pjnfs3/notes/bz34vrma3e.json added
+++ b/reviews/openreview/txi4pjnfs3/notes/bz34vrma3e.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "bZ34vrmA3e",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer 8Xit",+ "content": {+ "summary": "This work addresses the central challenge of noisy pseudo-labels in semi-supervised medical image segmentation by combining parametric network predictions with non-parametric prototype-based predictions. The method uses confidence-aware selection, prototype entropy minimization, and KL-based dual-space alignment to exploit the complementary strengths of both spaces. The claims of the paper are supported by experiments on ACDC, Left Atrium, and Pancreas-NIH, showing improvements over prior methods.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths:\n1. The pseudo-label noise problem is reinterpreted from the perspective of parametric vs. non-parametric prediction space.\n2. Semi-supervised segmentation in both 2D and 3D is covered.\n3. Confidence-aware selection is reasonable. It does not force alignment of all pixels, but only performs complementary learning when at least one space is reliable.\n\nWeaknesses:\n1. One point I am concerned about is the issue of innovation. As far as I know, prototype alignment is not a very new idea. For example, the following works all mention similar ideas [1-4]. I will refer to other reviewers' opinions on this point in the rebuttal.\n2. The authors used UNET/VNet as the backbone. I understand this is for fair comparison. However, some recent works have achieved better semi-supervised segmentation results using stronger backbones [5]. Please add a discussion and comparison.\n3. This paper uses a lot of hyperparameters and does not include ablation. I checked the appendix but could not find it. If I have missed it, please point it out. Otherwise, it should be added in the rebuttal. \n4. The author describes parametric prediction as \"easily affected by noise\" and prototype prediction as \"more stable.\" This intuition is reasonable, but there is no rigorous theoretical proof. Of course, the experiment seems to reflect this point. I think the authors should be more rigorous in their expression. It would be better if there were theoretical analysis (but not mandatory).\n\nRefs:\n\n[1]Xu, H., Liu, L., Bian, Q., & Yang, Z. (2022). Semi-supervised semantic segmentation with prototype-based consistency regularization. Advances in neural information processing systems, 35, 26007-26020.\n\n[2]Wang, Y., Xiao, B., Bi, X., Li, W., & Gao, X. (2024). Boundary-aware prototype in semi-supervised medical image segmentation. IEEE Transactions on Image Processing, 33, 5456-5467.\n\n[3]Yuan, Y., Wang, X., Yang, X., & Heng, P. A. (2024). Effective semi-supervised medical image segmentation with probabilistic representations and prototype learning. IEEE Transactions on Medical Imaging, 44(3), 1181-1193.\n\n[4]Zhang, H., Ma, P., Liu, J., Lian, J., & Ma, Y. (2025). Prototype-augmented mean teacher for robust semi-supervised medical image segmentation. Pattern Recognition, 166, 111722.\n\n[5]Yang, S., Xing, Z., & Zhu, L. VQ-Seg: Vector-Quantized Token Perturbation for Semi-Supervised Medical Image Segmentation. In The Thirty-ninth Annual Conference on Neural Information Processing Systems.",+ "quality": 3,+ "clarity": 2,+ "significance": 2,+ "originality": 2,+ "questions": "The main concern lies in the originality of the prototype-based method itself. Furthermore, I suggest adding a discussion and comparison of the mentioned references. Based on the opinions of other reviewers, if a majority of reviewers do not consider the originality problematic, and the authors have provided corresponding discussion and comparison results of the new methods, I will consider raising the score.",+ "limitations": "The authors briefly mention limitations in the checklist, but the discussion is not sufficiently explicit in the main paper.",+ "rating": 4,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "N/A",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "After considering the rebuttal and the discussion, I believe most of my main concerns have been adequately addressed. In particular, the authors clarified the distinction from prior prototype-based methods and added controlled experiments with homogeneous predictors, a stronger backbone, and hyperparameter sensitivity analyses, which substantially strengthen the empirical support. The remaining concern is mainly the limited methodological novelty, also noted by the AC and another reviewer. Overall, I believe the rebuttal resolves most technical concerns, while the novelty issue remains but is not severe enough to outweigh the strengths, so I raise my final rating to 4."+ },+ "createdAt": "2026-05-30T06:29:45.716Z",+ "modifiedAt": "2026-11-18T13:45:48.822Z",+ "url": "https://openreview.net/forum?id=Txi4PjNfS3¬eId=bZ34vrmA3e",+ "license": "CC-BY-4.0"+}
reviews/openreview/txi4pjnfs3/notes/pxssioygqf.json added
+++ b/reviews/openreview/txi4pjnfs3/notes/pxssioygqf.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "pXsSIoYgQF",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "The submission addresses semi-supervised image segmentation using a combination of parametric network predictions with non-parametric prototype-based predictions. This is a sensible approach, though not one that is particularly novel. In particular, Reviewers 8Xit and ojW2 both raise extensive concerns about the relationship to previous work. These concerns need to be addressed in a rebuttal. An additional concern is about the size of the effect of the method, with reviewers pointing out that the improvements over strong baselines are small.",+ "final_justification": "The authors have provided extremely extensive responses to the reviewer concerns. Two of three reviewers were engaged with the rebuttal process and raised their scores as a result. The submission's contribution was clarified, leading to improved overall assessment of the impact, and a large number of additional results and derivations were included. The authors will need to devote some effort in integrating these results/arguments into the final text."+ },+ "createdAt": "2026-09-24T11:28:52.457Z",+ "modifiedAt": "2026-11-18T15:00:06.812Z",+ "url": "https://openreview.net/forum?id=Txi4PjNfS3¬eId=pXsSIoYgQF",+ "license": "CC-BY-4.0"+}
reviews/openreview/txi4pjnfs3/notes/uuiz1c64ba.json added
+++ b/reviews/openreview/txi4pjnfs3/notes/uuiz1c64ba.json@@ -0,0 +1,31 @@+{+ "schema": "review/1",+ "id": "Uuiz1c64Ba",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer ojW2",+ "content": {+ "summary": "This paper proposed a so called \"parametric and non-parametric\" fused approach for medical image semi-supervised learning tasks. The idea is to combine a set of known techniques such as prototype learning, teacher-student learning, among others to achieve some better results on the benchmark.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "There are not much strengths I could find in the method design.\n\nExperimental results showed some advantages comparing to previous methods.\n\nWeaknesses:\n1. Combining known approaches and techniques, nothing really new in this paper, for example:\n\n1a. The current paper selects unlabeled pixels when either the parametric or prototype prediction is confident, using thresholds. This should be connected to earlier SSL work:\nMean Teacher — Tarvainen & Valpola, NeurIPS 2017. It introduced the EMA teacher/student consistency idea, which is foundational for many medical SSL segmentation methods.\nFixMatch — Sohn et al., NeurIPS 2020. It combines weak-to-strong consistency with confidence-thresholded pseudo-labeling, which is very close to the confidence-selection principle used here.\nUA-MT — Yu et al., MICCAI 2019. This is directly relevant because it uses uncertainty-aware self-ensembling for semi-supervised 3D left atrium segmentation.\nThis paper should not present confidence-aware selection as a major novelty unless it clearly explains how its two-space confidence rule differs from FixMatch-style confidence filtering and UA-MT-style uncertainty filtering.\n\n\n1b. The paper compares to several medical SSL methods, but its conceptual positioning could be sharper. The manuscript itself lists UA-MT, DTC, MC-Net, MCF, SS-Net, CauSSL, DualFete, BCP, GapMatch, β-FFT, ABD, GraphCL, and DyCON as related methods.\nImportant previous papers:\nDTC — Luo et al., AAAI 2021. It uses dual-task consistency between segmentation maps and level-set-derived maps, so it is an earlier example of using two prediction views/spaces for SSL regularization.\nBCP — Bai et al., CVPR 2023. It uses bidirectional copy-paste between labeled and unlabeled data in a Mean Teacher framework and reports strong results on LA, NIH-Pancreas, and ACDC, which overlap with this paper’s benchmarks.\nABD — Chi et al., CVPR 2024. It uses confidence-guided bidirectional displacement to suppress unreliable regions while still training on difficult content.\nDyCON — Assefa et al., CVPR 2025. It combines uncertainty-aware consistency and contrastive learning for semi-supervised medical segmentation, and is especially relevant because it treats uncertainty dynamically rather than simply filtering uncertain voxels.\nThis paper should explain whether its “dual-space” design is substantially different from earlier “dual-task,” “dual-branch,” “teacher-student,” and “uncertainty-aware” SSL methods, or whether it is mainly a new combination of existing ideas.\n\n\n1c. The current paper’s main framing is parametric prediction space versus non-parametric prototype space. It maintains class prototypes by EMA and predicts by cosine similarity between embeddings and prototypes. This should be compared more deeply with prototype-learning papers:\nPrototypical Networks — Snell et al., NeurIPS 2017. This is the classic reference for representing classes by prototypes in an embedding space.\nRethinking Semantic Segmentation: A Prototype View — Zhou et al., CVPR 2022. This is probably the most important conceptual reference, because it explicitly contrasts parametric segmentation heads with non-parametric prototype-based segmentation.\nSemi-supervised Semantic Segmentation via Prototypical Contrastive Learning — Chen & Lian, ACM MM 2022. It uses representative prototypes to denoise pseudo-labels, directly overlapping with this paper’s motivation about prototype robustness under pseudo-label noise.\nSelf-aware and Cross-sample Prototypical Learning for Semi-supervised Medical Image Segmentation — Zhang et al., MICCAI 2023. This is especially relevant because it already brings prototypical learning into semi-supervised medical segmentation.\nThis paper should not just say “we use prototypes.” It should clearly distinguish itself from prototype contrastive learning, cross-sample prototypical learning, and the CVPR 2022 prototype-view paper.\n\n1d. The manuscript argues that prototype embeddings provide more stable semantic structure than the parametric head. It also includes an embedding similarity analysis in Figure 4, where same-class high-similarity pixel pairs are often more consistent in embedding space than in parametric predictions. This connects to recent graph/contrastive SSL papers:\nGraphCL — Wang et al., 2024. It models graph structural information for semi-supervised medical image segmentation, using pairwise affinities and feature structure.\nDyCON — Assefa et al., CVPR 2025. It uses contrastive learning with uncertainty-aware weighting to improve feature separability under class imbalance and uncertainty.\nThis paper needs to show why prototype assignment is better than graph-based clustering, contrastive feature separation, or uncertainty-aware contrastive objectives.\n\n2. Presentation is not good enough. For example, figure 2 is expected to serve as the core component for illustrating the key idea, but it failed to deliver. Figure 2 needs rework.",+ "quality": 2,+ "clarity": 2,+ "significance": 1,+ "originality": 1,+ "questions": "1. What is exactly new in this paper?\n\n2. The reported improvements over strong recent baselines are promising but relatively small, often below one Dice point. Could the authors report mean ± standard deviation over multiple random seeds, or patient-level bootstrap confidence intervals, to show whether the improvements over methods such as β-FFT, DyCON, and DualFete are statistically reliable.",+ "limitations": "1. Lack of novelty and new insights for medical image semi-supervised learning.\n\n2. Besides the limited novelty, another main limitation of this work is that the empirical evidence may not yet fully support the breadth of the claims. The motivation for the complementary behavior of parametric and prototype-based predictions is mainly demonstrated on one dataset and one label-scarce setting, while the reported gains over recent baselines are small and are not accompanied by error bars or significance tests. In addition, the prototype branch is described as non-parametric, but it still depends on a learned projection head, learned embeddings, and EMA-updated prototypes, so its robustness to pseudo-label noise may depend strongly on representation quality and threshold calibration. A more complete analysis of multi-seed stability, threshold sensitivity, and failure cases would make the conclusions more convincing.",+ "rating": 2,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No concern here.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes"+ },+ "createdAt": "2026-06-16T03:16:12.742Z",+ "modifiedAt": "2026-11-18T13:45:47.594Z",+ "url": "https://openreview.net/forum?id=Txi4PjNfS3¬eId=Uuiz1c64Ba",+ "license": "CC-BY-4.0"+}
reviews/openreview/txi4pjnfs3/submission.json added
+++ b/reviews/openreview/txi4pjnfs3/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "Txi4PjNfS3",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 34921,+ "url": "https://openreview.net/forum?id=Txi4PjNfS3",+ "license": "CC-BY-4.0"+}
versions/v_ur57g97n.json added
+++ b/versions/v_ur57g97n.json@@ -0,0 +1,22 @@+{+ "date": "2026-05-05",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 34921,+ "url": "https://openreview.net/forum?id=Txi4PjNfS3",+ "reviews": "openreview/txi4pjnfs3",+ "evidence": [+ "https://openreview.net/forum?id=Txi4PjNfS3"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=Txi4PjNfS3",+ "evidence": [+ "https://openreview.net/forum?id=Txi4PjNfS3"+ ]+}