potentialpaper

Progressive Signal Calibration for Medical Image Segmentation: Diagnosing and Correcting Structural Misalignment in Training Signals

Import NeurIPS 2026 submission lClsEZgoUW: 8 notes

@openreview[bot] · 2026-11-22 17:59 UTC · 7908145a23e9

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,27 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "lClsEZgoUW"
+ }
+ ],
+ "title": "Progressive Signal Calibration for Medical Image Segmentation: Diagnosing and Correcting Structural Misalignment in Training Signals",
+ "authors": [
+ "Xinyan Zhao",
+ "Haijing Liu",
+ "Zhuan Cui",
+ "Tian Guan",
+ "Yonghong He",
+ "Wen Tang",
+ "Qiming He"
+ ],
+ "abstract": "Training-signal imbalance in medical image segmentation is commonly diagnosed as a data-distribution problem and addressed through reweighting, sampling, or domain adaptation. We argue that this diagnosis is incomplete: a more fundamental source is structural misalignment between supervision targets and segmentation objectives. We identify two operative mechanisms: gradient-mass dilution, where dominant classes consume gradient capacity needed for foreground discrimination, and inter-class supervision noise, where weak subtype boundaries generate unreliable optimization signals. On a private renal pathology dataset, four standard segmentation architectures trained under conventional four-class supervision underperform a foreground-focused (FG3) supervision regime (a one-line modification of the loss) by 3.85-11.79 fg-mIoU points when both arms are scored under the same foreground-restricted protocol, with all 95% intervals excluding zero. The effect replicates on a public histopathology dataset and on external cardiac MRI and echocardiography data, and exceeds matched inverse-frequency reweighting on the private and both external datasets. Building on this observation, we propose Progressive Signal Calibration (PSC), which calibrates training signals at three levels: it redefines the supervision target as foreground-focused or binary supervision, adds boundary-aware feature gating for structure-sensitive aggregation, and applies uncertainty- and ratio-aware constraints that prevent late-stage class-proportion drift. Importantly, PSC satisfies a conditional gain monotonicity property: its regularization terms contribute no gradient when inactive, and their gradient magnitude is bounded by the misalignment statistics when active. Across 18 public histopathology benchmarks under fixed binary supervision, PSC achieves statistically significant improvement on six datasets with no statistically significant regression on any benchmark. On the private renal pathology dataset, PSC reaches 96.0 fg-mIoU, exceeding the strongest matched-backbone baseline by +2.56 points under identical FG3 supervision (+2.42 in an independent three-seed comparison), a substantial gain over an FG3 baseline already above 93 fg-mIoU.",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/lclsezgouw/forms.json added

+++ b/reviews/openreview/lclsezgouw/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lclsezgouw/notes/71339wmky2.json added

+++ b/reviews/openreview/lclsezgouw/notes/71339wmky2.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "71339WmKY2",
+ "replyTo": "DLO6ISYdFw",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Thank you for the careful review and for recognizing the core value of the FG3 finding. Your suggestion to separate the transferable supervision-level contribution from the backbone-specific PSC stack materially improved the way we now organize the paper.\n\n*All intervals are 95% bootstrap. Private-dataset comparisons are per-image paired bootstrap over the 275 test images (`N = 1000`); the external MRI replication is patient-level paired bootstrap over 50 patients (`N = 1000`). Every fg-mIoU comparison is scored under one stated protocol on both arms.*\n\n> This is a very interesting paper with a clean and useful core finding. I would appreciate a clearer separation between the more general contribution (FG3 / supervision-target calibration, which is well-supported) and the PSC framework (which is supported on a single backbone). The analysis is appealing, but I am not yet convinced it generalises beyond the histopathology tasks shown.\n\nWe agree, and the revision now makes this separation explicit.\n\n- Part A is supervision-target calibration: the misalignment framing, Proposition 1, and the operators `Pi_FG3` / `Pi_bin`.\n- Part B is PSC as the concrete calibration stack: boundary-aware gating, uncertainty-boundary consistency, and the ratio-aware constraint.\n\nFor Part A, we now report the supervision effect in the same matched Protocol-B form used in the current draft:\n\n| Backbone | Delta fg-mIoU (FG3 - 4-class) | 95% CI |\n| --- | ---: | --- |\n| U-Net | +5.34 | [+3.11, +7.88] |\n| LinkNet+ECA | +11.79 | [+9.90, +13.92] |\n| SegMiT | +3.85 | [+1.82, +5.61] |\n| Swin-UMamba | +4.18 | [+2.04, +6.21] |\n| Ours (PSC) | +5.90 | [+5.05, +6.84] |\n\nAll five matched deltas are positive and all five intervals exclude zero, across CNN, transformer and Mamba families. This is the part of the paper we now present as the broader, more transferable result.\n\nFor Part B, we will keep the same-backbone module table visible rather than only describing it in prose:\n\n| fg-mIoU (%) | 4-class supervision | FG3 supervision |\n| --- | ---: | ---: |\n| Swin-UMamba (modules off) | 89.27 | 93.45 |\n| Ours (PSC, modules on) | 90.11 | 96.01 |\n| **Module effect** | +0.84, CI [-0.27, +2.08] | **+2.56, CI [+0.40, +5.23]** |\n\nThe interaction is `+1.72`, CI `[+0.09, +3.47]`. This makes the positive result for the PSC stack explicit: once supervision is fixed, the module contribution is small under 4-class supervision and clearly positive under FG3 supervision. An independent three-seed rerun under a unified seed/schedule/stopping protocol reproduces the same module comparison at `+2.42`, so the magnitude is not a single-run artifact.\n\nTo address the generality concern directly, we also completed an external replication on a different modality — ACDC cardiac MRI, U-Net backbone, matched 4-class vs `Pi_FG3` under one protocol, patient-level paired bootstrap (`n = 50` patients):\n\n| Metric (%) | 4-class | FG3 | Delta | 95% CI |\n| --- | ---: | ---: | ---: | --- |\n| fg-mIoU | 88.532 | 93.232 | +4.700 | [+4.225, +5.199] |\n| fg-Recall | 91.699 | 96.472 | +4.773 | [+4.310, +5.301] |\n| fg-Precision | 96.224 | 96.478 | +0.254 | [+0.124, +0.391] |\n\nOne property of this result is worth stating explicitly, because it is stronger than \"the effect also appears in another domain\": the ACDC point estimate of `+4.700` falls inside the interval measured for the same backbone on our histopathology data (U-Net, `+5.34`, CI `[+3.11, +7.88]`). Same architecture, same protocol, different organ and different imaging modality, and the two estimates are mutually consistent rather than merely both positive. In the revision, we will state the generality claim at exactly the level the evidence supports: renal histopathology, five matched backbones, and one external cardiac-MRI replication, with broader applicability stated as a hypothesis.\n\n> Proposition 2 reads more as an intuition than a result, since only empirical evidence is provided to support it.\n\nWe agree that the grounding needed to be stated more concretely. In the revision, Proposition 2 is tied directly to a three-rater audit on 100 held-out renal images: boundary-pixel Cohen's `kappa` is `0.78` for PCT vs atrophic-PCT, `0.61` for PCT vs DCT, and `0.34` for DCT vs atrophic-PCT. The one pair the proposition predicts should be unreliable is exactly the pair the annotators disagree on, and its morphological explanation is concrete: brush-border loss in atrophic PCT can resemble normal DCT at the working magnification. We therefore present Proposition 2 as a testable claim supported here by measured subtype-boundary unreliability on that specific pair, not as a broad theorem.\n\n> `Pi_bin` is introduced before it is defined.\n\nCorrected. The revision will define both operators at first mention as\n\n\\[\n\\Pi_{\\mathrm{FG3}}(y_k)=\n\\begin{cases}\n\\mathrm{ignore}, & y_k = 0,\\\\\ny_k - 1, & y_k > 0,\n\\end{cases}\n\\qquad\n\\Pi_{\\mathrm{bin}}(y_k)=\\mathbf{1}[y_k > 0].\n\\]\n\n> I believe Equation (5) should contain an indicator function.\n\nCorrected. Eq. (5) will explicitly write the indicator function as `\\mathbf{1}[y_k > 0]`.\n\n> The three-phase schedule is introduced abruptly.\n\nCorrected. The revision introduces each phase where it first becomes relevant: Phase 1 diagnostic warmup on the base loss only, Phase 2 calibrated training with the modules active, and Phase 3 attenuation of the regularization terms after validation saturates.\n\n> PSC is presented both as a conceptual contribution and as a concrete model.\n\nThis is precisely what the Part A / Part B split is intended to fix. Part A is the conceptual claim — the supervision target is a design degree of freedom, with two concrete operators that anyone can apply as a one-line change to their loss — and Part B is the concrete instantiation on one backbone. The two now carry separate scopes and separate evidence.\n\n> How sensitive are the conclusions to ground-truth annotation quality?\n\nDirectly sensitive, and we now say so as part of the mechanism rather than as a caveat. The same three-rater analysis shows that `Pi_FG3` can redistribute gradient mass toward foreground discrimination but cannot recover subtype distinctions that the labels themselves barely support: the residual gap to perfect fg-mIoU is concentrated on the one measured pair at `kappa = 0.34` rather than on unexplained saturation. The annotator-agreement analysis therefore moves from the supplement into the main discussion.\n\nYour comments led to several concrete improvements in the paper: a cleaner Part A / Part B split, more careful scope wording, a completed cross-modality replication, and a tighter mechanism statement tied to measured annotation reliability. We hope the revised structure now matches the evidence more faithfully."
+ },
+ "createdAt": "2026-07-28T11:56:17.682Z",
+ "modifiedAt": "2026-11-18T17:21:32.912Z",
+ "url": "https://openreview.net/forum?id=lClsEZgoUW&noteId=71339WmKY2",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lclsezgouw/notes/a8iorxcb6u.json added

+++ b/reviews/openreview/lclsezgouw/notes/a8iorxcb6u.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "a8iOrXcB6U",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer YLwk",
+ "content": {
+ "summary": "This paper investigates the issue of training-signal imbalance in medical image segmentation. The authors posit that the root cause may be a structural misalignment between the supervision target and the actual segmentation objective. They decompose this misalignment into two mechanisms, gradient-mass dilution and inter-class supervision noise, and propose a method called Progressive Signal Calibration (PSC). Experimentally, the authors first compare standard four-class supervision with foreground-focused supervision using a private kidney pathology dataset; they then evaluate the performance of PSC relative to the backbone across 18 public histopathology datasets and introduce an activation gating rule based on warmup statistics.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths.\n1. On a private renal pathology dataset, simply ignoring the background in the loss function led to a noticeable improvement in foreground mIoU across multiple backbones. This phenomenon is noteworthy, given that many medical segmentation tasks involve large background areas and relatively small foreground structures.\n2. In addition to the private dataset, the authors report per-dataset results across 18 public histopathology datasets and assess statistical significance using paired bootstrap confidence intervals, making the experimental findings more compelling.\n3. The ablation studies are clearly presented; Tables 1 and 2 help distinguish between the gains attributable to FG3 itself and those resulting from the additional PSC components.\n\nWeaknesses.\n1. FG3 ignores background loss and merges all foreground categories under binary supervision; these practices are no longer equivalent to the original multi-class segmentation task. The authors attribute the significant performance gains observed under binary supervision to \"inter-class supervision noise,\" a claim that warrants a more cautious interpretation.\n2. Although the paper positions FG3 as a \"general-purpose recipe,\" it lacks comparisons against more direct baselines for handling class imbalance. Without appropriate controls, it is difficult to determine whether the improvements stem from the redefinition of the supervision target or simply from better handling of class imbalance.\n3. Across 18 public datasets, PSC yields an average improvement of approximately +0.013 fg-mIoU, indicating that the magnitude of the gain is modest. Without comparisons against strong imbalance-aware or boundary-aware methods under the same binary supervision setting, it is hard to assess whether PSC significantly outperforms existing training techniques.\n4. The figures in the \"Full PSC\" row of Table 2 do not perfectly match those for \"Ours FG3\" in Table 1; the authors attribute this discrepancy to differences in random seeds and early stopping sweeps. Given that Table 2 is intended to demonstrate the independent contributions and additivity of the various components, the ablation results should be re-reported using a consistent seed, training schedule, and stopping criterion.",
+ "quality": 2,
+ "clarity": 3,
+ "significance": 2,
+ "originality": 2,
+ "questions": "1. Under the FG3 setting, does the calculation of fg-mIoU include pixels in the background region that are predicted as foreground in the union for the foreground category? Or are background regions ignored during evaluation? This distinction directly affects the interpretation of Table 1.\n2. It is currently difficult to distinguish whether the performance gains stem from \"changing the supervision target\" or from \"better handling of class imbalance.\" Could the authors include imbalance baselines that preserve the original multi-class labels?\n3. The tasks corresponding to binary supervision and multi-class/FG-focused supervision in Table 3 are not identical. If the fine-grained subtypes themselves hold clinical significance, should the binary mode still be considered a performance improvement?\n4. There are significant discrepancies between the ablation figures in Table 2 and the matched-backbone figures in Table 1. Could the authors re-report the ablation results for each component using the same random seed, training schedule, and stopping criterion?",
+ "limitations": "A critical limitation has not been sufficiently emphasized: binary mode may sacrifice clinically useful subtype information, and the improvement in fg-mIoU alone is insufficient to justify it. The authors should more clearly articulate the scope of applicability for PSC. If subtype classification is an integral part of the clinical problem, then binary supervision might not merely be a form of calibration, but rather a fundamental alteration of the problem definition itself.",
+ "rating": 4,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No paper formatting concerns.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The additional experiments alleviate my main concerns. The unified-protocol results, matched imbalance baselines, external validations, and factorial analysis provide stronger evidence for both the FG3 effect and the additional contribution of the PSC modules. While the evaluation-protocol inconsistency and the relationship between FG3 and conventional imbalance handling still require careful revision, the new evidence strengthens the paper."
+ },
+ "createdAt": "2026-06-24T03:28:33.611Z",
+ "modifiedAt": "2026-11-18T13:45:57.626Z",
+ "url": "https://openreview.net/forum?id=lClsEZgoUW&noteId=a8iOrXcB6U",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lclsezgouw/notes/dlo6isydfw.json added

+++ b/reviews/openreview/lclsezgouw/notes/dlo6isydfw.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "DLO6ISYdFw",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer qXHq",
+ "content": {
+ "summary": "The paper reframes a problem usually treated as class imbalance into one of structural misalignment between the supervision target and the segmentation objective. The authors identify two mechanisms behind the failure of standard segmentation training: gradient-mass dilution, where an abundant background class dominates the gradient and hurts foreground inter-class discrimination, and inter-class supervision noise, where weakly defined foreground subtype boundaries inject noise rather than signal. Empirically, simply excluding background from the loss (FG3) consistently improves foreground mIoU up to +16.05 points across four backbones on 4 different datasets.\n\nFrom this observation, the authors propose Progressive Signal Calibration (PSC), built on the Swin-UMamba backbone (Swin encoder, FPN decoder, Mamba refinement). PSC calibrates supervision at three levels: an annotation level that selects FG3 or binary supervision depending on the misalignment; an architectural level with a boundary-aware feature gating module supervised by morphological edge labels and retained at inference; and a regularization level with two training-only constraints, an uncertainty-boundary consistency term (UBC) aligning predictive uncertainty with the boundary response, and a ratio-aware constraint (RAC) combining a ratio prior estimated from the training set with a KL anchor to the warmup-phase predictions. Training proceeds in three phases: a diagnostic warmup that estimates dataset statistics $\\Phi(\\mathcal{D})$ and the prediction prior, a calibration phase that activates all constraints, and a final phase that attenuates regularisation once validation saturates.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths:\n- The paper is well motivated, and its observations are very interesting. FG3 is simple and easy to implement, and should be known by the community.\n- The empirical analysis is very thorough. The propositions (shortcomings) highlighted are empirically validated. The losses and architectural components of their proposed model are ablated.\n- Conditional gain monotonicity framing is very thoughtful.\n\nWeaknesses:\n- The contribution would benefit from sharper scoping. FG3 is architecture-agnostic and convincingly demonstrated. The rest of the PSC framework is very tied to the new architecture proposed, and it is less clear that the \"task-signal misalignment\" reframing generalises beyond histopathology, or how sensitive the conclusions are to ground-truth annotation quality.\n- PSC is presented both as a conceptual contribution about supervision and as a concrete model with a three-stage schedule, which I found, at first, makes the paper a bit difficult to follow.",
+ "quality": 4,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "This is a very interesting paper with a clean and useful core finding. I would appreciate a clearer separation between the more general contribution (FG3 / supervision-target calibration, which is well-supported) and the PSC framework (which is supported on a single backbone). The analysis is appealing, but I am not yet convinced it generalises beyond the histopathology tasks shown.\n\n\nRemarks:\nProposition 2 reads more as an intuition than a result, since only empirical evidence is provided to support it.\n\\Pi_{bin} is introduced before it is defined.\nI believe Equation (5) should contain an indicator function.",
+ "limitations": "yes",
+ "rating": 5,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "None",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I am maintaining my original rating and thank the authors for their thoroughness during the rebuttal stage."
+ },
+ "createdAt": "2026-06-25T00:02:01.358Z",
+ "modifiedAt": "2026-11-18T13:45:56.062Z",
+ "url": "https://openreview.net/forum?id=lClsEZgoUW&noteId=DLO6ISYdFw",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lclsezgouw/notes/m3bui0gcjy.json added

+++ b/reviews/openreview/lclsezgouw/notes/m3bui0gcjy.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "m3buI0GcJY",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer 3RRX",
+ "content": {
+ "summary": "This paper studies training-signal imbalance in medical image segmentation from the perspective of supervision-target misalignment. The authors argue that conventional multi-class supervision can be suboptimal when background pixels dominate the loss or when fine-grained foreground categories have unreliable boundaries.\n\nTo address this, the paper proposes Progressive Signal Calibration (PSC), which combines annotation-level supervision recalibration (foreground-focused or binary supervision), boundary-aware feature gating, and uncertainty- and ratio-aware regularization. Experiments on a private renal pathology dataset and 18 public histopathology datasets suggest that redefining the supervision target can substantially improve segmentation performance, with PSC providing additional gains on top of the recalibrated supervision.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "**Strengths**\n\nThis paper is motivated by a practically relevant issue in medical image segmentation: the original annotation taxonomy may not provide the most effective supervision signal for the desired segmentation objective. The central empirical observation—that background-dominated multi-class supervision can substantially impair foreground discrimination, while unreliable fine-grained subtype labels can introduce harmful supervision noise—is intuitive, clearly articulated, and potentially useful beyond the specific proposed architecture.\n\nA major strength is the empirical evidence for supervision recalibration. Foreground-focused supervision yields large and consistent gains across several backbones on the private renal pathology dataset, and the study further examines the role of supervision granularity on multiple public pathology datasets. The evaluation is broad for a use-inspired submission, covering one private dataset and 18 public histopathology benchmarks, with ablations for the architectural and regularization components and paired bootstrap confidence intervals. The paper is also generally well organized: the distinction between annotation-level, architectural-level, and regularization-level calibration makes the overall framework easy to follow.\n\n**Weaknesses**\n\nThe paper's strongest result appears to be the simple change in supervision definition—ignoring background pixels or merging unreliable foreground subclasses—rather than the full PSC framework. In comparison, the incremental contribution of boundary gating, uncertainty-boundary consistency, and ratio-aware regularization is less clearly isolated across the public benchmark suite. It would be helpful to understand whether these components provide consistent gains beyond the supervision recalibration baseline, rather than primarily on the private dataset.\n\nThe broader generality of the proposed principle also remains somewhat unclear. Although the paper evaluates many datasets, all public experiments are within histopathology segmentation, while the paper presents task-signal misalignment as a more general property of pixel-imbalanced segmentation. In addition, the proposed activation rule is evaluated over only 18 datasets, and the theoretical conditional-gain result relies substantially on the explicit gating design. Further evidence is needed to clarify how robustly the diagnostic rule and the claimed safety property transfer to new domains, architectures, and annotation settings.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "1. Could the authors provide a per-dataset comparison between the matched backbone trained with the same recalibrated supervision (especially Pi_bin) and the full PSC model? This would clarify whether the public-benchmark gains come consistently from the PSC modules themselves, rather than mainly from supervision recalibration.\n\n2. The selection between FG3 and binary supervision is currently manual. Can the authors provide a quantitative analysis—e.g., based on subtype agreement, class separability, or confusion patterns—to justify this choice across datasets? This would strengthen the claim that PSC offers a principled calibration strategy rather than two manually chosen operating modes.\n\n3. The activation gate is evaluated using only 18 datasets. Please report the number of positive/negative datasets, the precise definition of “PSC-effective,” and the LODO performance of simple single-feature baselines. This would help assess the robustness and practical usefulness of the 94.4% gating accuracy.\n\n4. The conditional gain monotonicity theorem seems to depend substantially on manually setting regularization weights to zero when the gate is inactive. Could the authors clarify the nontrivial content of the on-regime result and provide evidence for behavior near the gating threshold?",
+ "limitations": "The authors discuss several relevant limitations, including manual selection between FG3 and binary supervision and the limited scope of the activation gate. However, the limitations section should more explicitly acknowledge that the central claims are validated only on histopathology segmentation datasets, despite being framed as broadly applicable to pixel-imbalanced segmentation. It would also be useful to discuss the potential practical cost of collapsing clinically meaningful subtypes into binary labels: while this may improve the reported segmentation metric, it can reduce the clinical utility of predictions when subtype-level distinctions are required.",
+ "rating": 4,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No major formatting or anonymity concerns noticed.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The authors have addressed my main concerns with additional matched comparisons, loss baselines, and clearer scoping. The newly provided experiments, including the revised matched comparison against inverse-frequency weighting and cross-architecture evaluations, strengthen the evidence that PSC provides additional gains beyond supervision recalibration. While the improvement attributable solely to PSC appears smaller than the overall gain introduced by the supervision change, the updated results suggest that PSC contributes non-trivial benefits rather than merely serving as a byproduct of the supervision design. I appreciate the authors' more cautious claims regarding automatic calibration and binary supervision."
+ },
+ "createdAt": "2026-06-25T14:43:06.004Z",
+ "modifiedAt": "2026-11-18T13:45:54.307Z",
+ "url": "https://openreview.net/forum?id=lClsEZgoUW&noteId=m3buI0GcJY",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lclsezgouw/notes/mqtuhapj3r.json added

+++ b/reviews/openreview/lclsezgouw/notes/mqtuhapj3r.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "mQtuHaPJ3r",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair DRWq",
+ "content": {
+ "metareview": "The initial meta-review asked whether the gains come from the full method or mainly from the supervision change it builds on. The matched factorial and per-dataset results answered this: the modules add a smaller but real gain on top of the supervision change, which is the transferable finding. The discussion also produced three corrections that the authors acknowledge: Table 1's protocol mismatch, which roughly halves the headline gains; the withdrawn gate-accuracy figure; and the reweighting comparison, rerun with a longer budget after an unfavorable preliminary, leaving a residual of about one point. The camera-ready must replace every protocol-inconsistent value and label protocols throughout, replace the gate figure, report the reweighting comparison with its history, and scope the binary-supervision and generality claims accordingly. One reference (karimi2023deep) carries a wrong title, year, and arXiv identifier and should be corrected in the camera-ready."
+ },
+ "createdAt": "2026-07-14T23:39:50.341Z",
+ "modifiedAt": "2026-11-18T15:26:08.656Z",
+ "url": "https://openreview.net/forum?id=lClsEZgoUW&noteId=mQtuHaPJ3r",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lclsezgouw/notes/ns3eww8lq6.json added

+++ b/reviews/openreview/lclsezgouw/notes/ns3eww8lq6.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "nS3Eww8Lq6",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "The initial meta-review asked whether the gains come from the full method or mainly from the supervision change it builds on. The matched factorial and per-dataset results answered this: the modules add a smaller but real gain on top of the supervision change, which is the transferable finding. The discussion also produced three corrections that the authors acknowledge: Table 1's protocol mismatch, which roughly halves the headline gains; the withdrawn gate-accuracy figure; and the reweighting comparison, rerun with a longer budget after an unfavorable preliminary, leaving a residual of about one point. The camera-ready must replace every protocol-inconsistent value and label protocols throughout, replace the gate figure, report the reweighting comparison with its history, and scope the binary-supervision and generality claims accordingly. One reference (karimi2023deep) carries a wrong title, year, and arXiv identifier and should be corrected in the camera-ready.",
+ "final_justification": "The decision-relevant question, whether the gains come from the full method or mainly from the supervision change it builds on, was answered with matched factorial and per-dataset results; the panel converged at 4, 5, 4. Three corrections surfaced during discussion (Table 1 protocol mismatch, a withdrawn gate figure, a rerun reweighting comparison); the surviving effect is smaller than submitted, hence the poster recommendation."
+ },
+ "createdAt": "2026-09-24T11:29:07.625Z",
+ "modifiedAt": "2026-11-18T15:00:11.125Z",
+ "url": "https://openreview.net/forum?id=lClsEZgoUW&noteId=nS3Eww8Lq6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lclsezgouw/notes/pdrshkeqgt.json added

+++ b/reviews/openreview/lclsezgouw/notes/pdrshkeqgt.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "PDrShKEQGt",
+ "replyTo": "a8iOrXcB6U",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Thank you for focusing on the most decision-relevant controls: evaluation protocol, imbalance-preserving baselines, task-definition scope, and matched ablation provenance. Your comments led us to tighten both the experiments and the wording.\n\n*All intervals are 95% bootstrap. Private-dataset comparisons are per-image paired bootstrap over the 275 test images (`N = 1000`); the external MRI replication is patient-level paired bootstrap over 50 patients (`N = 1000`).*\n\nUnder FG3, the discrimination-facing score is Protocol B: evaluation is restricted to ground-truth foreground pixels, matching the `ignore_index` training mask. We agree that this must be stated explicitly, so the revision will name both conventions wherever a number is shown:\n\n- Protocol B: evaluate only on ground-truth foreground pixels.\n- Protocol A: evaluate on all pixels, so foreground false positives on background are penalized.\n\nUnder the matched Protocol-B convention, the five-backbone supervision effect is `+3.85` to `+11.79`, with all five intervals excluding zero. This is the correct interpretation of the FG3 numbers in Table 1: they are Protocol-B gains in foreground discrimination, not deployment-facing all-pixel gains by themselves. We will make that explicit in the revision instead of leaving it implicit.\n\nYour question also prompted three verifications of the evaluator itself, which we now report rather than assert:\n\n- **Protocol B forgives exactly the background-false-positive term and nothing else.** Foreground recall is numerically identical across the two conventions on every dataset where both are computable: `91.46` vs `91.458` on the private test set, and `91.699` under either protocol on ACDC. Only precision, and hence fg-mIoU, changes.\n- **The FG3 effect is a curve shift, not an operating-point shift.** On the matched Swin-UMamba backbone the Protocol-B effect decomposes as recall `+5.61`, precision `-1.19`, net fg-mIoU `+4.18`. A pure move along a fixed precision–recall curve would leave IoU flat or lower; here IoU rises, so the curve itself moves. On ACDC the same decomposition is recall-driven with no precision cost (`+4.773` recall, `+0.254` precision), and we report both cases rather than generalizing from one.\n- **Negative control on the metric code.** Deliberately merging class 1 into background drops fg-mIoU from `0.827` to `0.495`, confirming that the label-mapping path is live rather than a silent identity.\n\nYes. We ran matched multi-class-preserving loss controls on the private dataset. The labels, backbone, and split are fixed; only the loss is changed.\n\n| Setting | Protocol A | Protocol B | Delta vs vanilla (B) | 95% CI |\n| --- | ---: | ---: | ---: | --- |\n| 4-class vanilla | 84.17 | 89.27 | — | — |\n| + inverse-frequency weights | 79.68 | **93.50** | **+4.23** | [+3.41, +5.15] |\n| + sqrt-inverse weights | 82.01 | 90.87 | +1.60 | [−0.05, +2.88] |\n| + heuristic (1:3:5:4) weights | 80.95 | 91.52 | +2.25 | [+0.99, +3.35] |\n| + focal × inverse-frequency | 78.13 | 92.27 | +3.01 | [+1.25, +4.44] |\n| + generalized Dice | 76.16 | 81.65 | −7.62 | — |\n| + plain Dice | — | 78.85 | −10.41 | [−13.10, −7.79] |\n| + CE + Dice (nnU-Net standard) | 81.27 | — | — | — |\n| **Pi_FG3** (same backbone) | — | **93.45** | **+4.18** | [+2.04, +6.21] |\n\n*All loss variants use the vanilla-tuned schedule with no per-loss hyperparameter search, so they should be read as untuned-under-matched-protocol rather than as tuned upper bounds.*\n\nThis table supports a narrower and more defensible interpretation than the original draft. The completed multi-class-preserving controls are heterogeneous: some improve Protocol B, but **every one of them falls below the 4-class vanilla baseline under Protocol A**, and the degradation is monotone in reweighting strength (`82.01` for sqrt-inverse, `80.95` for the heuristic, `79.68` for inverse-frequency) — the signature of buying foreground discrimination with background rejection. The nnU-Net-standard CE + Dice combination reaches `81.27` under Protocol A, also below vanilla, so this is not an artifact of an unweighted Dice objective alone.\n\nBy contrast, Full PSC reaches `86.63` under Protocol A, which is `+2.46` above the 4-class vanilla arm and above every reweighted control under the deployment-facing convention. Against the matched single-stage 4-class PSC arm at `84.90` — the same checkpoint that appears at `90.11` under Protocol B in the factorial above — the paired gain is `+1.74`, CI `[+1.03, +2.45]`. We therefore do not claim that FG3 \"beats all imbalance methods\"; the claim is that the effect is not reducible to a trivial reweighting artifact, and that deployment-facing behavior must be checked separately under Protocol A.\n\nWe agree that this requires more cautious wording. In the revision, binary mode will be presented as a scope-limited operating mode, not as a universal improvement. To separate label-space change from mechanism interpretation, we also ran a same-binary-scoring control on BCSS: the 4-class model's own predictions are merged with `{0 -> 0, 1..K -> 1}` before scoring, so both arms sit in the same binary label space. The resulting gap (binary supervision minus merged multi-class+background) is `+0.0185`, with CI `[-0.0123, +0.0524]`. We report this completed null: it is not strong enough to treat raw binary-vs-multiclass gaps as standalone proof of the inter-class-noise mechanism.\n\nAccordingly, the revision will make three changes. First, where subtype distinctions are clinically important, binary mode will not be presented as the preferred setting. Second, the renal case will continue to use `Pi_FG3`, not `Pi_bin`, precisely because those subtype distinctions are clinically meaningful there. Third, when we discuss the noise mechanism, we will tie it to measured annotator disagreement on the renal dataset (DCT vs atrophic-PCT, `kappa = 0.34`) rather than to the size of a binary-vs-multiclass score gap alone. The supervision-target contribution itself remains anchored on the five-backbone FG3 comparison and the external MRI replication, both of which hold the number of foreground classes fixed and are therefore unaffected by this concern.\n\n> There are significant discrepancies between the ablation figures in Table 2 and the matched-backbone figures in Table 1. Could the authors re-report the ablation results for each component using the same random seed, training schedule, and stopping criterion?\n\nWe agree that the ablation should be re-reported under a unified protocol. The revision will use the same three-seed summary that is already in the current draft:\n\n| Configuration | fg-mIoU (%) | fg-Recall (%) | Delta vs base |\n| --- | ---: | ---: | ---: |\n| Base (modules inactive) | 92.45 ± 0.87 | 96.63 ± 0.38 | — |\n| + UBC | 92.77 ± 1.84 | 96.74 ± 0.68 | +0.32 |\n| + TAG (boundary gating) | 93.11 ± 0.76 | 96.79 ± 0.34 | +0.66 |\n| + RAC (ratio prior) | 93.57 ± 1.10 | 97.04 ± 0.33 | +1.12 |\n| **Full PSC** | **94.87 ± 1.02** | **97.49 ± 0.48** | **+2.42** |\n\nWe will state the conclusion in a narrower way than before: Full PSC is above the matched base by more than the seed spread, and both metrics recover the same overall ordering — fg-Recall, whose seed spread is roughly two to three times tighter (`0.33–0.68` vs `0.76–1.84`), reproduces it independently — while we avoid strong claims about fine separation among individual modules at `n = 3`. This batch also cross-checks the matched factorial from a different source of variance: `+2.42` here (training variance across seeds) against `+2.56` there (test-set sampling variance for a fixed pair of checkpoints).\n\nYour remaining weakness note — that the `+0.013` average across 18 datasets is modest, and that stronger comparators are needed — deserves a direct answer as well.\n\nOn the average: `+0.013` (that is, `+1.31` points) is a mixture rather than a typical case. Split by the gate's out-of-fold LODO prediction, the six datasets predicted PSC-effective average `+3.03` points and the remaining twelve average `+0.45`, and together these reproduce the `+1.31` overall. We use the prediction rather than the `epsilon`-defined label for this split so that it is not circular. On the separate criterion of interval significance, six datasets have intervals excluding zero with gains from `+1.00` to `+4.68` points, and none of the 18 is significantly negative — these two groups of six are defined differently and are not the same set. The literal statement the suite supports is therefore: significant gains of one to nearly five points on a third of the panel, attenuation toward zero elsewhere, and no significant regression anywhere. The magnitude claim itself rests on the matched private comparisons and the external replication, not on the pooled average, and the revision rewrites the abstract so that `+0.013` carries the safety-and-generality claim it was meant to carry.\n\nOn comparators: the completed comparator evidence is the matched loss-control table above, now including nnU-Net-standard CE + Dice. It answers the causal question in your review directly — the FG3 effect is not explained away by ordinary imbalance handling, only partially and non-uniformly reproduced by it. A tuned benchmark-wide external sweep would license a broader claim than we have earned, so the revision does not assert superiority over the wider imbalance-aware literature.\n\nAll experiments added in this revision directly address the four concerns raised in your review, and all critical textual revisions are guided by your comments. The paper has achieved substantial improvements through supplementary experimental results and more rigorous wording. We hope the newly added experiments fully resolve the reservations underlying your review score."
+ },
+ "createdAt": "2026-07-28T11:59:37.461Z",
+ "modifiedAt": "2026-11-18T17:21:33.429Z",
+ "url": "https://openreview.net/forum?id=lClsEZgoUW&noteId=PDrShKEQGt",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lclsezgouw/notes/ypa18r6kft.json added

+++ b/reviews/openreview/lclsezgouw/notes/ypa18r6kft.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "yPA18R6kFt",
+ "replyTo": "m3buI0GcJY",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Thank you for a review that turned broad concerns into concrete checks. Your four questions prompted the most important provenance and matched-design audits in this rebuttal, and the revision is substantially stronger because of them.\n\n*All intervals are 95% bootstrap. Private-dataset comparisons are per-image paired bootstrap over the 275 test images (`N = 1000`); the external MRI replication is patient-level paired bootstrap over 50 patients (`N = 1000`). Every fg-mIoU comparison is scored under one stated protocol on both arms.*\n\n> Could the authors provide a per-dataset comparison between the matched backbone trained with the same recalibrated supervision (especially Pi_bin) and the full PSC model? This would clarify whether the public-benchmark gains come consistently from the PSC modules themselves, rather than mainly from supervision recalibration.\n\nYes. We now make the matched design explicit and separate the private factorial from the public `Pi_bin` comparison.\n\nOn the private dataset, the matched factorial is:\n\n| fg-mIoU (%) | 4-class supervision | FG3 supervision | Supervision effect |\n| --- | ---: | ---: | --- |\n| Swin-UMamba (modules off) | 89.27 | 93.45 | +4.18, CI [+2.04, +6.21] |\n| PSC (modules on) | 90.11 | 96.01 | +5.90, CI [+5.05, +6.84] |\n| Module effect | +0.84, CI [-0.27, +2.08] | +2.56, CI [+0.40, +5.23] | interaction +1.72, CI [+0.09, +3.47] |\n\nOn the public benchmark, both arms use the same fixed `Pi_bin` supervision, and both retain the boundary branch in the graph: the Base arm keeps the branch with class-aware boundary supervision and UBC disabled. The reported per-dataset delta therefore substantially isolates the incremental TAG/UBC/RAC contribution within the shared-branch matched design, with the branch's own capacity absorbed identically on both sides. Across the 18 datasets this gives **6 significantly positive, 0 significantly negative, and 12 intervals containing zero**, with the six significant gains running from `+1.00` to `+4.68` fg-mIoU points. We also re-audited this batch end to end for this response, including verifying that the train/validation/test split contents are identical across the two arms on all 18 datasets.\n\nUnder the other supervision mode, the matched comparison uses the four datasets on which `Pi_FG3` training is defined, with backbone and supervision fixed on both arms: `EBHI +3.71`, CI `[+0.15, +7.51]`; `BCSS +0.48`, CI `[-0.37, +1.31]`; `WSSS4LUAD +0.38`, CI `[-0.52, +1.39]`; `PanNuke -0.93`, CI `[-1.77, +0.09]`. We report the weakest case rather than omit it: one significant improvement, and no significant regression, since the PanNuke interval contains zero. We will state the conclusion narrowly as \"significant gains on some datasets, no significant regression on either panel,\" and provide the full per-dataset table in the revision.\n\n> The selection between FG3 and binary supervision is currently manual. Can the authors provide a quantitative analysis—e.g., based on subtype agreement, class separability, or confusion patterns—to justify this choice across datasets? This would strengthen the claim that PSC offers a principled calibration strategy rather than two manually chosen operating modes.\n\nWe can justify the renal choice quantitatively, but we do not want to overclaim cross-dataset automation. The criterion we use is semantic boundary strength, `s_ij = kappa_ij * KL(p_i || p_j)`, combining inter-annotator agreement with feature distinctiveness. On the renal dataset it flags DCT vs atrophic-PCT as the weak pair (`kappa = 0.34`), while PCT vs DCT (`0.61`) and PCT vs atrophic-PCT (`0.78`) remain substantially stronger. That supports our use of `Pi_FG3` there. What we cannot yet claim is a validated cross-dataset selector, because `kappa_ij` requires multi-annotator redundancy that only one of our datasets has. In the revision, we will present this as quantitative justification for the renal case and as a basis for future validation, not as a solved universal selector.\n\n> The activation gate is evaluated using only 18 datasets. Please report the number of positive/negative datasets, the precise definition of “PSC-effective,” and the LODO performance of simple single-feature baselines. This would help assess the robustness and practical usefulness of the 94.4% gating accuracy.\n\nWe now report all three explicitly under a unified, warmup-only definition.\n\n- `PSC-effective(D) := 1[(fg-mIoU_full - fg-mIoU_base) > 0.012]`\n- `(n_pos, n_neg) = (7, 11)`\n- majority baseline = `61.1% (11/18)`\n\nRequested LODO baselines are: majority `61.1% (11/18)`, `f_fg 27.8% (5/18)`, `n_cls 27.8% (5/18)`, `rho_cls 83.3% (15/18)`, `bg_ratio 27.8% (5/18)`, `v_mIoU 50.0% (9/18)`, `rho_cls + bg_ratio 77.8% (14/18)`, and the depth-2 tree over all five `Phi(D)` components `72.2% (13/18)`.\n\nThree points about this ladder, all of which came directly from the baselines you asked for.\n\n- **`epsilon = 0.012` is a gap in the data, not a tuned value.** Sorting the 18 per-dataset deltas, the 7th largest is `0.0151` and the 8th is `0.0100`, with nothing in between. Any `epsilon` in that interval yields the identical `(7, 11)` labelling, and `0.012` sits near its midpoint. The labelling is recomputable from the paper's own per-dataset table.\n- **The predictive signal is concentrated in one feature, and this is mechanistically coherent rather than a concession.** The gate predicts *module* effectiveness, and the modules act on structure and on class proportion within the foreground, which is what `rho_cls` measures. The `bg_ratio` mechanism of Proposition 1 is handled at the annotation level by the choice of `Pi`, not by the modules, so its absence from the gate is what the framework predicts. Adding features costs accuracy at this sample size (`77.8%`, `72.2%`) rather than gaining it.\n- **We state the resolution honestly.** At `n = 18`, the difference between `83.3%` and the majority baseline is four datasets, so `Phi(D)` is presented as a descriptive diagnostic and automatic activation gating as open work.\n\nFollowing your suggestion, we re-audited the gate with more rigorous data provenance, a computation rule unified with the paper's stated `Phi(D)`-only warmup setting, and a clearer mechanism interpretation. Under that unified definition, the gate is best summarized by the single-feature `rho_cls` rule at `83.3%`, which remains well above the `61.1%` majority baseline. The earlier `94.4%` exploratory tree depended on an extra variable not declared in the main-text `Phi(D)` definition, so it will no longer be used as the main-text gate result. The number changes; the conclusion does not.\n\n> The conditional gain monotonicity theorem seems to depend substantially on manually setting regularization weights to zero when the gate is inactive. Could the authors clarify the nontrivial content of the on-regime result and provide evidence for behavior near the gating threshold?\n\nWe agree that the original exposition foregrounded the easier part. In the revision we will distinguish the two claims more explicitly.\n\n- Off-regime: this is the design guarantee. If the gate is inactive, the associated regularization weights are zero, so that gradient contribution is exactly absent.\n- On-regime: this is the nontrivial rate-bound statement. When the gate is active, the extra regularization magnitude is controlled by the mismatch statistics rather than allowed to grow arbitrarily. The bound comes from the loss definitions rather than from gate attenuation, which is why the two are separated in the assumption list.\n\nFor near-threshold behavior, we now report the three audited errors of the `Phi(D)`-only LODO gate directly:\n\n| Error type | Dataset(s) | Observed delta |\n| --- | --- | ---: |\n| False positive | Kumar | -0.0007, CI [-0.018, +0.013] |\n| False negative | CoCAHis | +0.0151 |\n| False negative | CRAG | +0.0180 |\n\nOn this 18-dataset panel, the observed cost around the threshold is therefore one null activation whose interval contains zero and two forgone gains, not a clear harmful regression. This is the empirical counterpart of the off-regime guarantee, and it is consistent with the zero significant regressions observed across the 18 datasets. One further distinction is worth stating so a reader does not have to reconcile it: the theorem bounds gradient *magnitude*, not *marginal benefit*, which is why the module gain can be larger under `Pi_FG3` even though the mismatch statistics there are lower.\n\nYour limitation comment also prompted a cross-modality replication, which we will add visibly to the revision. This is ACDC cardiac MRI with a U-Net backbone (background plus right ventricle, myocardium, left ventricle), matched 4-class vs `Pi_FG3` under one protocol, patient-level paired bootstrap (`n = 50` patients):\n\n| Metric (%) | 4-class | FG3 | Delta | 95% CI |\n| --- | ---: | ---: | ---: | --- |\n| fg-mIoU | 88.532 | 93.232 | +4.700 | [+4.225, +5.199] |\n| fg-Recall | 91.699 | 96.472 | +4.773 | [+4.310, +5.301] |\n| fg-Precision | 96.224 | 96.478 | +0.254 | [+0.124, +0.391] |\n\nThe per-patient precision delta is positive on 41 of the 50 test patients, so the effect is broad-based rather than outlier-driven, and the fg-mIoU point estimate falls inside the interval measured for the same backbone on our histopathology data (U-Net, `+5.34`, CI `[+3.11, +7.88]`) — different organ, different modality, mutually consistent estimates rather than merely both positive.\n\nWe will also accept your scope refinement directly in the paper: the current evidence supports histopathology plus one external MRI replication, while broader generality remains a hypothesis; and `Pi_bin` will be described as a scope-limited operating mode rather than a universal recommendation when subtype distinctions are clinically load-bearing."
+ },
+ "createdAt": "2026-07-28T11:55:16.098Z",
+ "modifiedAt": "2026-11-18T17:21:32.764Z",
+ "url": "https://openreview.net/forum?id=lClsEZgoUW&noteId=yPA18R6kFt",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/lclsezgouw/submission.json added

+++ b/reviews/openreview/lclsezgouw/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "lClsEZgoUW",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 35544,
+ "url": "https://openreview.net/forum?id=lClsEZgoUW",
+ "license": "CC-BY-4.0"
+}

versions/v_dryjq5kj.json added

+++ b/versions/v_dryjq5kj.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-05-05",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 35544,
+ "url": "https://openreview.net/forum?id=lClsEZgoUW",
+ "reviews": "openreview/lclsezgouw",
+ "evidence": [
+ "https://openreview.net/forum?id=lClsEZgoUW"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=lClsEZgoUW",
+ "evidence": [
+ "https://openreview.net/forum?id=lClsEZgoUW"
+ ]
+}