PULSE: Probabilistic Uncertainty-Aware Longitudinal Simulation for EHR Trajectories
Import NeurIPS 2026 submission seIHyi0c7e: 5 notes
@openreview[bot] · 2026-11-22 17:59 UTC · 32eb03e0be59
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,23 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "seIHyi0c7e"+ }+ ],+ "title": "PULSE: Probabilistic Uncertainty-Aware Longitudinal Simulation for EHR Trajectories",+ "authors": [+ "Robert Lennart Manschke",+ "Angus Roberts",+ "Julia Ive"+ ],+ "abstract": "Realistic intensive-care electronic health record trajectories are difficult to simulate because physiology, treatments, observation times, and patient state co-evolve under sparse clinical measurement. We introduce PULSE, a probabilistic simulator family for intensive care trajectories. PULSE separates treatment from patient-state generation, predicts binary patient state before continuous physiology, and represents uncertainty with patient-dependent output distributions. Covariance groups assign variables to shared decoders, and a monotone B-spline flow models each continuous distribution. On a MIMIC-IV sepsis cohort scored over 37 variables, the B-spline model achieves vector-normalized root mean squared error of 6.556 and 5.805 when forecasting from hours two and six, compared with 6.845 and 6.277 for our G-Transformer reimplementation. Its continuous ranked probability score is 0.4625 and 0.3930, compared with 0.5191 and 0.4725 for that baseline. Paired patient-bootstrap intervals support improvements in both scores at both origins. A continuous normalizing flow achieves similar scores in the same evaluation. Cross-dataset experiments examine transfer to eICU. A controlled benchmark based on CVSim [Heldt et al., 2010] shows that a model can learn treatment responses under known synthetic dynamics.",+ "year": 2026,+ "venue": "NeurIPS 2026",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/seihyi0c7e/forms.json added
+++ b/reviews/openreview/seihyi0c7e/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/seihyi0c7e/notes/dcll4ptabs.json added
+++ b/reviews/openreview/seihyi0c7e/notes/dcll4ptabs.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "DClL4ptaBS",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer wjJE",+ "content": {+ "summary": "This study proposes PULSE (Probabilistic Uncertainty-Aware Longitudinal Simulation), an autoregressive ICU state simulator generating treatment, binary patient state, and continuous physiology in order. PULSE follows G-computation's formula of explicitly modeling treatment and covariate evolution, and like G-Transformer, PULSE works with irregularly recorded EHR time series.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "== Strength ==\nComprehensive evaluation that includes point evaluation, probabilistic evaluation, and counterfactual evaluation. Extensive baselines. Exploration of different methods for residual prediction.\n\n== Weakness ==\n1. PULSE has a complicated pipeline with multiple components (Figure 1). There is a detailed description of the \"residual distribution\" block, but the other components do not seem to be described to the same level of detail, and requires inferring them from the rollout diagram and the Figure 1 caption. Overall, I think the text would benefit from reworking to improve clarity and make it easier to follow, such as providing a figure or text description of the overall model architecture.\n\n2. It is not clear to me what distinguishes PULSE from G-transformer (which seems to be the main reference of prior work). I think the paper can benefit from explicitly highlighting what is added or modified relative to G-transformer, as well as the motivation behind each new design choice.\n\n3. Nitpick: Figure 1 could use some polish. The line below \"b_{t+1}\" is not straight, and \"b_t+1\" should be replaced with proper subscript formatting.",+ "quality": 3,+ "clarity": 2,+ "significance": 3,+ "originality": 3,+ "questions": "1. What is the motivation for conditioning the continuous state on the binary state, and how confident are you that the causal direction is correctly specified?\n\n2. What EHR data is used exactly? Table A.3 in the appendix defines the 37 variables of the continuous state, but I did not see a corresponding definition for the binary state. Is any static patient data used in addition to the state variables for prediction? What is the action space?\n\n3. Several variables in the continuous state are highly correlated, for example Heart Rate, Diastolic Blood Pressure, Systolic Blood Pressure, Mean Blood Pressure, and etc. Since RMSE is averaged over variables according to Appendix A.2, could this correlation bias the reported RMSE?\n\n4. Which of the reported errors are under teacher forcing?\n\n5. What is the backbone model? I could not seem to find which model PULSE is built on. \n\n6. Line 159 explains that a learned residual is added to x_{t,v}^anchor, described as the variable-specific carry-forward state. Does this mean the predicted continuous state only provides a hidden representation for the residual to condition on, rather than directly predicting the absolute value of the next continuous state? I could not find a detailed description of the model architecture beyond the high-level rollout diagram in the figure.\n\n7. Line 122 mentions \"Teacher forcing and, new with PULSE, scheduled sampling.\" Could you explain the scheduled sampling setup in more detail? I did not see it discussed elsewhere in the paper.",+ "limitations": "In the checklist, it says \"Limitations are discussed in Section 6, including cohort mismatch, incomplete multi-seed evidence, transition-head limitations, and the distinction between factual MIMIC rollout and CVSim known-effect counterfactual validation.\" \n\nI didn't find the discussion on \"incomplete multi-seed evidence, transition-head limitations\", am I missing something?",+ "rating": 4,+ "confidence": 2,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "I am raising my score from 3 to 4. The rebuttal supplied previously missing details, including backbone architecture and variable/action-space definitions. It also clarified what is retained from G-Transformer versus what has changed, which helps me better understand the paper's contribution. The authors were transparent in response to my question about correlation and RMSE, noting that under a correlation-normalized metric PULSE's advantage over G-Transformer persists but \"by a slightly lower margin.\" I'd encourage the authors to incorporate these clarifications into the main text by moving other supplemental (yet necessary) details to the appendix if space is a constraint."+ },+ "createdAt": "2026-07-01T05:00:35.118Z",+ "modifiedAt": "2026-11-18T13:46:01.257Z",+ "url": "https://openreview.net/forum?id=seIHyi0c7e¬eId=DClL4ptaBS",+ "license": "CC-BY-4.0"+}
reviews/openreview/seihyi0c7e/notes/hkphtxjkgw.json added
+++ b/reviews/openreview/seihyi0c7e/notes/hkphtxjkgw.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "hkPHTXjKGW",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "This paper proposes a patient-specific ICU EHR trajectory simulator and has reasonably thorough experimental results. Before the author/reviewer discussion period, reviews were mixed (1 accept, 2 borderline rejects) and reviewers raised concerns regarding clarity/exposition and relating the proposed method to G-transformer (for more details, see the reviews from reviewers Uw9K and wjJE). After the author/reviewer discussion period, reviews became slightly more positive but are still mixed (1 accept, 1 borderline accept, 1 borderline reject). The authors addressed much of the concerns (e.g., explaining how the proposed method is different from G-transformer, various clarity/exposition issue). I looked at the concerns from the borderline reject review and I think they have been adequately addressed by the authors. I am recommending that this paper be accepted.",+ "final_justification": "My meta-review already includes my updated justification."+ },+ "createdAt": "2026-09-24T11:29:14.243Z",+ "modifiedAt": "2026-11-18T15:00:15.671Z",+ "url": "https://openreview.net/forum?id=seIHyi0c7e¬eId=hkPHTXjKGW",+ "license": "CC-BY-4.0"+}
reviews/openreview/seihyi0c7e/notes/hl0fatpczp.json added
+++ b/reviews/openreview/seihyi0c7e/notes/hl0fatpczp.json@@ -0,0 +1,31 @@+{+ "schema": "review/1",+ "id": "hL0fAtpCZP",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Uw9K",+ "content": {+ "summary": "The manuscript describes a simulator (PULSE) for trajectories of patient-specific measurements in intensive care units. The model tries to disentangle discrete patient states and continuous physiology states.\nThe experiments are carried out on a subset of the MIMIC IV cohort (v3.1). The appendix (strictly not part of the paper) contains some results using the as well as on the eICU data and the CVSim simulator.",+ "contribution_type": "use_inspired",+ "strengths_and_weaknesses": "Strengths\n* The code in the supplement seems to render the work rather straightforward to reproduce.\n\nWeaknesses\n* The second half of the abstract contains extremely condensed text which is very hard to read.\n* The trajectories constitute a fixed rollout and are not updated along the way. There is no observational data assimilated.\n* The description of the model is rather dense and hard to digest.\n* The authors could explain in more depth the motivation\n* I did not find the exact split of the MIMIC IV cohort used. Also, it would be good to know how the code will be made available if the manuscript should get accepted.",+ "quality": 2,+ "clarity": 1,+ "significance": 2,+ "originality": 3,+ "questions": "* Which application scenario do you have in mind for the simulator? Is it about forecasting decision points, chasing treatment errors or optimising ressource allocation? Please provide details how this should be integrated.\n* Following up on the prior question. What makes a \"good\" trajectory in the first place?\n* Could you please describe in more clarity which data is recorded by which devices and what a trajectory is composed of in general?\n* Can you please make an attempt which aspects of the trajectory can be well modeled (as they are follow rules/standards etc.) and which aspects are essentially random interventions?",+ "limitations": "yes",+ "rating": 3,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes"+ },+ "createdAt": "2026-07-04T15:54:25.968Z",+ "modifiedAt": "2026-11-18T13:45:59.890Z",+ "url": "https://openreview.net/forum?id=seIHyi0c7e¬eId=hL0fAtpCZP",+ "license": "CC-BY-4.0"+}
reviews/openreview/seihyi0c7e/notes/jax5dybqv3.json added
+++ b/reviews/openreview/seihyi0c7e/notes/jax5dybqv3.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "JaX5dYBQV3",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer v5Ss",+ "content": {+ "summary": "PULSE is a family of probabilistic simulators for ICU EHR trajectories. The main idea is to split the modeling of treatment rollout, binary patient-state rollout, and continuous physiology rollout, then improve the continuous dynamics with anchored residual updates around the last observed or simulated value. The probabilistic variants add event-time features, heteroscedastic Gaussian heads, B-spline residual flows, latent severity pooling, and covariance-aware residual grouping. The paper evaluates these design choices on MIMIC-IV sepsis trajectories, eICU transfer panels, and CVSim known-effect counterfactual tests.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "The paper has strong points and the problem setup is well motivated. The authors note that ICU trajectory simulation must model treatment assignment, patient state, irregular observation time, and continuous physiology together, and that simple residual sampling is often not enough to capture state-dependent uncertainty. The proposed factorization is also easy to follow. The model predicts binary state before continuous state, separates treatment from state rollout, and generates continuous variables through anchored residual dynamics that keep a persistence prior while still allowing learned deviations. \n\nThe empirical evaluation is also more comprehensive than in many simulator papers I have read. The main MIMIC predictive-check table compares against carry-forward, population mean, XGBoost autoregression, Causal Transformer, and G-Transformer, and it reports paired bootstrap confidence intervals instead of only single numbers. On the main factual rollout metric, PULSE-Anchor improves over carry-forward at both horizons, and the paper also shows that the anchored residual formulation is better than the older per-covariate G-Transformer baseline in the matched evaluation. The probabilistic analysis is another strength since the paper discusses Gaussian heads, B-spline heads, CRPS, WIS, PIT, inclusion rates, and state-dependent width variation, which is much better than a paper that only reports RMSE.\n\nHowever, the main weakness is that the strongest claims still go a bit beyond the evidence. The paper does show that anchored rollout improves factual prediction, but the gains are modest rather than surprising, especially when compared with strong persistence-style baselines. In several settings, carry-forward and train-population mean remain competitive. That is an important reminder that a simulator can look good on aggregate RMSE while still being weak in realistic rollout behavior. The authors do acknowledge this, which is good, but it also limits how far the realism claim can be pushed.\n\nA second weakness is that the probabilistic story is mixed. Gaussian heads seem strongest on aggregate calibration metrics, while B-spline flows seem better at shaping state-dependent residual density and sometimes improve point rollout. That is interesting scientifically, but it also means the probabilistic extension is not clearly better than the simpler anchored mean model in every setting. So the paper gives useful analysis of uncertainty, but not one clean win for the most expressive probabilistic variant.\n\nA third concern is external validity. The eICU transfer panels are useful, but several rows are negative relative to carry-forward or population mean, which suggests that the method does not transfer cleanly across sources and variable panels. The MIMIC-seeded CVSim transfer is also still weaker in harder regimes. These are not fatal problems, but they do mean the paper is better read as a strong factual-rollout and uncertainty-modeling paper than as a fully solved simulator for cross-domain clinical counterfactuals.\n\nThe paper is also quite dense, and some of the methodological complexity feels heavier than the final gains justify.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "A compact ablation table that removes one ingredient at a time would make it easier to see whether the improvement comes primarily from the carry-forward anchor, from continuous time features, or from the residual distribution family.\n\nSince the discussion identifies death/release timing as a major error source, an ablation that models stay-in-ICU, release, and death more explicitly would test whether the current gains are bounded mainly by status timing rather than by physiology modeling.",+ "limitations": "The authors are unusually honest about limitations, which I appreciate.",+ "rating": 5,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "Still revising it."+ },+ "createdAt": "2026-06-24T21:35:55.811Z",+ "modifiedAt": "2026-11-18T13:46:02.353Z",+ "url": "https://openreview.net/forum?id=seIHyi0c7e¬eId=JaX5dYBQV3",+ "license": "CC-BY-4.0"+}
reviews/openreview/seihyi0c7e/notes/xigif4ofpu.json added
+++ b/reviews/openreview/seihyi0c7e/notes/xigif4ofpu.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "xIGif4OFPU",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair v3A3",+ "content": {+ "metareview": "This paper proposes a patient-specific ICU EHR trajectory simulator and has reasonably thorough experimental results. Before the author/reviewer discussion period, reviews were mixed (1 accept, 2 borderline rejects) and reviewers raised concerns regarding clarity/exposition and relating the proposed method to G-transformer (for more details, see the reviews from reviewers Uw9K and wjJE). After the author/reviewer discussion period, reviews became slightly more positive but are still mixed (1 accept, 1 borderline accept, 1 borderline reject). The authors addressed much of the concerns (e.g., explaining how the proposed method is different from G-transformer, various clarity/exposition issue). I looked at the concerns from the borderline reject review and I think they have been adequately addressed by the authors. I am recommending that this paper be accepted."+ },+ "createdAt": "2026-07-21T21:52:59.476Z",+ "modifiedAt": "2026-11-18T15:26:12.996Z",+ "url": "https://openreview.net/forum?id=seIHyi0c7e¬eId=xIGif4OFPU",+ "license": "CC-BY-4.0"+}
reviews/openreview/seihyi0c7e/submission.json added
+++ b/reviews/openreview/seihyi0c7e/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "seIHyi0c7e",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 35902,+ "url": "https://openreview.net/forum?id=seIHyi0c7e",+ "license": "CC-BY-4.0"+}
versions/v_hhgb77tj.json added
+++ b/versions/v_hhgb77tj.json@@ -0,0 +1,22 @@+{+ "date": "2026-05-05",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 35902,+ "url": "https://openreview.net/forum?id=seIHyi0c7e",+ "reviews": "openreview/seihyi0c7e",+ "evidence": [+ "https://openreview.net/forum?id=seIHyi0c7e"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=seIHyi0c7e",+ "evidence": [+ "https://openreview.net/forum?id=seIHyi0c7e"+ ]+}