potentialpaper

PULSE: Probabilistic Uncertainty-Aware Longitudinal Simulation for EHR Trajectories

Update NeurIPS 2026 submission seIHyi0c7e: 10 notes

@openreview[bot] · 2026-11-24 15:56 UTC · a262fa815272 ·

Evidence

reviews/openreview/seihyi0c7e/notes/3a1ka7sewx.json added

+++ b/reviews/openreview/seihyi0c7e/notes/3a1ka7sewx.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "3a1KA7SewX",
+ "replyTo": "cSIQ5dXhRE",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Revised abstract attempt",
+ "comment": "We attempted to rewrite the abstract in a way that is hopefully more parseable. Please feel free to let us know if you prefer this version, or if perhaps there is even more clarity needed. given that the review period ends soon, we'd love to follow any suggestions, but it might be difficult to follow another round of back-and-forth. In general, we're happy to rewrite/clarify anything in the paper.\n\nnew suggested abstract:\n\n\nRealistic simulation of ICU EHR trajectories is challenging because patient physiology, treatments, observation timing, and survival state evolve together under sparse clinical measurement. We introduce PULSE, a probabilistic simulator that separates treatment assignment from patient-state progression, predicts binary patient state before continuous physiology, and models physiological changes through anchored residual dynamics around the most recently observed or simulated state.\n\nWe evaluate PULSE on a MIMIC-IV sepsis cohort across 37 clinical variables, comparing it with carry-forward, population mean, XGBoost autoregression, Causal Transformer, and G-Transformer baselines. Unlike evaluations based only on single performance estimates, we report paired patient-level bootstrap confidence intervals. PULSE-Anchor improves over carry-forward at both evaluated rollout horizons. At the six-step horizon, it reduces vector-normalized RMSE from 6.633 for carry-forward to 5.969 and outperforms a matched per-covariate G-Transformer baseline, which achieves 7.124. These results support the value of the anchored residual formulation for stable multi-step simulation.\n\nBecause RMSE alone can favour unrealistic straight-line predictions such as carry-forward, we also evaluate probabilistic calibration and distributional realism using CRPS, WIS, PIT, interval inclusion rates, and state-dependent interval-width variation. Gaussian PULSE achieves the strongest overall CRPS, while B-spline flows better represent non-Gaussian, state-dependent residual distributions. Adding continuous clock-time inputs, next-observation-time and observation-probability prediction, and residual anchoring jointly reduces B-spline rollout RMSE from 8.301 to 6.635 for trajectories generated from post-admission hour (k=6) through hour 24 and produces more adaptive uncertainty estimates. Improvements over carry-forward persist on an external eICU sepsis cohort. Controlled CVSim experiments further show that PULSE can learn treatment responses under mechanistic ground truth, although transfer to MIMIC-based counterfactual settings remains limited. Overall, PULSE improves factual ICU trajectory simulation while providing a broader assessment of uncertainty and distributional realism than RMSE-only evaluation."
+ },
+ "createdAt": "2026-08-03T11:40:40.818Z",
+ "modifiedAt": "2026-11-19T16:45:58.883Z",
+ "url": "https://openreview.net/forum?id=seIHyi0c7e&noteId=3a1KA7SewX",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/seihyi0c7e/notes/a4ulcapgzp.json added

+++ b/reviews/openreview/seihyi0c7e/notes/a4ulcapgzp.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "a4ulcApgZp",
+ "replyTo": "xIGif4OFPU",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you for your guidance with this meta-review. We've tried our best to at least shortly address everything the two borderline-reject reviewers have said as early as possible in the discussion phase. We see wjJE has changed their rating to a 4 now, which we of course appreciate greatly. We've also provided responses to Uw9K - we hope these resolve the remaining concerns. \n\nWe noticed many of the weaknesses from Uw9K and wjJE refer to clarity but would be easy to fix with an update to the text, for which we offered alternative formulations. The content-related points they raise are very interesting, though some of them are questions that we cannot yet answer. For v5Ss, we tried to deliver the requested ablation tables (although it did take us some time to re-run some of the ablative experiments and we were able to respond fully only yesterday night). It seems that v5Ss was the only one who found our paper easy to follow, and we take this home as a message to try to write more clearly in the future. We'll also gladly clarify any further issues in the camera-ready version. We hope that our attempt to address both borderline-rejects can be considered favorably."
+ },
+ "createdAt": "2026-08-04T10:09:14.870Z",
+ "modifiedAt": "2026-11-19T16:45:58.682Z",
+ "url": "https://openreview.net/forum?id=seIHyi0c7e&noteId=a4ulcApgZp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/seihyi0c7e/notes/csiq5dxhre.json added

+++ b/reviews/openreview/seihyi0c7e/notes/csiq5dxhre.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "cSIQ5dXhRE",
+ "replyTo": "hL0fAtpCZP",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "We thank the reviewer for their time and sensible criticism. Some of these questions are active research, but we would be happy to adapt and clarify phrasing/text and tried to provide more detail on motivation here.",
+ "comment": "re: abstract\n\nWe have no attachment to the exact phrasing of the abstract and can adjust it to summarize results more readably without listing so many separate findings. For example:\n“[...] Gaussian NLL is the strongest calibrated PULSE variant by CRPS, while B-spline flows address the non-Gaussian shape of factual residuals. The flow-based continuous-time output heads improve VRMSE from 8.301 to 6.635, yielding sharper, more state-dependent residual densities. B-spline intervals improve the state-to-state variation coefficient 0.79 vs 0.48 over gaussian outputs with higher interval coverage and better local skew and sharpness. Similar gains over carry-forward persist on an eICU sepsis validation cohort. CVSim known-effect [...]” \n\nre: trajectories\n\nWe followed literature measuring coherence in counterfactual rollout, a weakness of next-step-trained transformers. For simulation, long-horizon rollout error is more relevant than short-horizon error. Evaluation generates one variable-length step at a time, so observations can be assimilated by replacing selected states. Prompted by this review, we tested this: open-loop PULSE scores 6.046 VRMSE versus carry-forward's 6.292 (3.9% better); assimilation every six hours improves this to 5.158 versus 5.441 (5.2% better). We would be happy to add this assimilated evaluation to the main text or appendix.\n\nre: dense model description\n\nWe can clarify the model by focusing on differences from G-Transformer and introducing fewer variants in the paper text. concisely, PULSE groups variables by covariance, anchors predictions in carry-forward, adds a Gaussian distribution around this anchor, and uses B-spline flows to transform the Gaussian or mixture base into a flexible learned density.\n\nmotivation\n\nWe prioritized results under the page limit, but we could try expanding the paragraph aobut motivations. Existing g-computation models use empirical noise independent of patient state. Without it, trajectories vary little; with it, variation looks diverse but is largely uninformative about the patient. PULSE makes distributional outputs its core innovation, allowing uncertainty and residual shape to depend on generated state.\n\nThis also motivates grouping medically correlated variables, improving parameter efficiency without materially reducing performance. Existing methods fail to beat naive carry-forward in our matched long-horizon setting. PULSE starts from carry-forward and learns departures, producing lower VRMSE and more realistic conditional uncertainty. Although we question VRMSE as a sole simulator metric, PULSE improves it alongside the reported probabilistic metrics.\n\ncode\n\nIf accepted, we plan to open-source PULSE and its reproduction code, ideally already linking it in the camera-ready paper. \n\nMIMIC-IV cohort split\n\nWe're not quite sure what is meant by this, the paper reports a subject-level split of 8,934 subjects: 7,147 training, 893 validation, and 894 test stays. We matched cited MIMIC-IV, Sepsis-3, and G-Transformer definitions as closely as possible for comparability. \n\nQuestions:\n\napplication scenario\n\nWe consider the paper as is an application of machine learning methodologies as it is, but we can imagine many use cases for a more realistic simulator. The original motivation was synthetic data generation and its broader applicaitons, a few other use cases could be dose titration, an uncertainty-enabled tool for test/resource allocation, and predicting hard-to-plan concepts such as unplanned ITU admissions. Many of these use-cases would of course need much clinical validation, but we think that our approach does make all of them much more viable.\n\n\"good\" trajectory\n\nDefining this is an active focus of ours. Present work improves established metrics, while CRPS, PIT KS, WIS, interval coverage, autocorrelation, cross-correlation, and death/release timing provide a broader picture. Some scores miss shortcomings visible on manual inspection, so no single metric seems to define a good trajectory.\n\nmore detailed data/trajectory composition\n\nMIMIC-IV specifies clinical sources, but exact manufacturers or device types are not specified, as far as we know. A trajectory contains 37 continuous variables plus edema, diagnosis-derived cardiac/pulmonary status, diuretic use, dialysis, ventilation, death, and ICU release. In terms of action space, the current treatment model predicts only bolus volume and vasopressor use; we hope to expand this in the future.\n\nwell modeled vs random interventions\n\nCVSim provides a useful proxy: many variables follow mechanistic rules, while real data contain measurement error and patient variation. PULSE estimates uncertainty conditional on state and measurement context. Treatment timing and frequency are also informative and partly rule-governed. A dynamic policy with state-dependent uncertainty and calibrated distributions can model more variation, while CVSim supplies known-effect evaluation unavailable in factual MIMIC."
+ },
+ "createdAt": "2026-07-28T22:40:01.560Z",
+ "modifiedAt": "2026-11-19T16:45:58.790Z",
+ "url": "https://openreview.net/forum?id=seIHyi0c7e&noteId=cSIQ5dXhRE",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/seihyi0c7e/notes/gjxr2vfo7e.json added

+++ b/reviews/openreview/seihyi0c7e/notes/gjxr2vfo7e.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "gjXR2VFO7E",
+ "replyTo": "DClL4ptaBS",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "We thank the reviewer for their time and detailed, constructive criticism. Several questions identify places where our concise wording might have obscured important architectural and evaluation details; we appreciate the opportunity to clarify them here and would be happy to revise the text and Figure 1 accordingly. We attempt to address everything in this short comment format.",
+ "comment": "= Weakness ==\ncomplexity/figure notes\nWe can improve camera-ready text (and Figure 1). We wanted to reply quickly, but can suggest new text before the author window closes.\n\nComparison vs G-Transformer\n\nPULSE retains G-Transformer's multi-decoder factorization: separate continuous and categorical variables, next-step prediction, treatments and covariates as history entries, and representation learning. We updated most other elements: covariance-grouped decoders, continuous-time encodings, observation gates, next-measurement timing, and carry-forward-anchored residuals. The basic probabilistic model outputs Gaussian parameters mu and sigma; variants add a second Gaussian, B-spline flow, or continuous normalizing flow conditioned on hidden state through an MLP. Covariance grouping followed a physiologically inspired manual grouping that already improved efficiency.\n\nCausal direction\nWe believe the chain-rule based factorization here works both ways; it does not establish a causal edge. Binary sampling is cheap, and sampled or teacher-forced binary state helps continuous outputs remain consistent. We can try to formulate this more precisely in the text.\n\nEHR data/action space\nBinary state contains edema, diagnosis-derived pulmonary-edema/heart-failure status, diuretic use, dialysis, ventilation, death, and ICU release. Treatment variables are bolus volume (continuous) and vasopressors (binary). Diuretics, dialysis, and ventilation are still modeled as outcomes. Static context contains age, gender, pre-ICU fluid amount, Elixhauser score, end-stage renal failure, and congestive heart failure.\n\nCorrelation effect on RMSE\nWhile valid criticism of RMSE, we think Correlation does not invalidate the error scores and patient-resampled confidence intervals assume no channel independence. Correlation does affect VRMSE weighting: the effective rank of the 37x37 correlation matrix is around 16; Even in a fully normalized-to-variable-count RMSE, though, PULSE does beat G-Transformer, albeit by a slightly lower margin. We generally matched variables, VRMSE, and cohort to G-Transformer as closely as possible.\n\nWhich reported errors are under teacher forcing?\nTable 2 uses Monte Carlo rollouts with no factual future observations after forecast origin, averaged per patient before RMSE. Other rows supplying factual future state or treatment labels are marked error decompositions and excluded from rankings. Table 2's empirical state+treatment row uses train-fit generated components. To improve clarity, we could also state this explicitly in table headings?\n\nWhat is the backbone model?\nThe backbone comprises grouped causal Transformer decoders with hidden size 64, two layers, four attention heads, and dropout 0.1. It is similar to G-Transformer, with covariance grouping and adaptation MLPs for multiple output heads. Gaussian and normalizing-flow heads are core additions and, as far as we know, have not previously been applied to EHR trajectory simulation, but depending on semantics these might not be considered \"backbone\".\n\npredicted continuous state only provides a hidden representation for the residual?\nCorrect. The model initializes to the identity operation on the last known value and learns the change. Hidden state conditions all output heads: residual, Gaussian, MoG, B-spline, or CNF.\n\nScheduled sampling\nThank you; this is an oversight. Scheduled sampling was introduced by Bengio et al. (NeurIPS 2015). \"New with PULSE\" meant new relative to G-Transformer, not ownership of the concept; we will revise this section to make sure the citation is added correctly, as we had previously not been aware of the paper, one of us authors had added it based on a web search result. Scheduled sampling gradually substitutes detached model outputs into factual history according to an epoch-derived probability to bridge teacher-forced training and autoregressive rollout. Submitted PULSE-Anchor used full teacher forcing, while selected probabilistic variants enabled scheduled sampling. All validation and testing were entirely free-run, non-teacher-forced unless otherwise specified.\n\nLimitations:\n\"incomplete multi-seed evidence, transition-head limitations\", am I missing something?:\nWe accidentally retained the multi-seed point in the checklist after adding bootstrapped confidence intervals and removing the related discussion sentence; the bootstrap intervals might also need a small revision, as they are currently not fully re-trained, only re-sampled. Response-period runs across seeds 7, 42, and 137 give anchored k=6 range 6.114-6.128. The “transition head limitations” part refers to the text about death and release affecting VRMSE significantly - perhaps this is a bit too condensed to put in the checklist, we were trying to be very concise with that; we’d be happy to rephrase, e.g. “absorbing-state error limitation”, or just remove this mention entirely."
+ },
+ "createdAt": "2026-07-28T23:06:11.568Z",
+ "modifiedAt": "2026-11-19T16:45:58.770Z",
+ "url": "https://openreview.net/forum?id=seIHyi0c7e&noteId=gjXR2VFO7E",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/seihyi0c7e/notes/js86maqx0o.json added

+++ b/reviews/openreview/seihyi0c7e/notes/js86maqx0o.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "Js86MAqX0o",
+ "replyTo": "JaX5dYBQV3",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We tried our best to produce these ablation tables in time. \n\nCaveat: CNF-8 here uses a slightly updated implementation that we didn't yet have in the paper, which we found after some optimization is actually faster than the B-spline model. This is despite the fact that our hyperparameter grid search resulted in a significantly larger backbone model (hidden 256, 4 layers, 8 heads instead of 64,2,4) - meaning that while the CNF-8 head does allow scaling the backbone model better, it is also necessary to keep the model this large to achieve the desired performance. Despite the 26x larger core model, the CNF-8 is still faster in wallclock time for both training and inference. We did also fix a few bugs and improved/finished the then-prototype CNF implementation off a bit since the paper code artifact was created.\n\nAll rows use sampled rollouts. Bold marks best and italics marks second-best within each section.\n\n| Step | N | M | Anchor | Gate | CT | Next | Obs | Cov | Family | VRMSE↓ | CRPS↓ | WIS↓ | PIT-KS↓ | Cov90→.90 | r(σ,error)↑ |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|---|---:|---:|---:|---:|---:|---:|\n| Absolute static | 891 | 100 | 0 | 0 | 0 | 0 | 0 | 0 | static Gaussian | 11.071 | 0.900 | 3.477 | *0.064* | **0.892** | 0.128 |\n| + carry-forward anchor | 891 | 100 | 1 | 0 | 0 | 0 | 0 | 0 | static Gaussian | 8.497 | 0.788 | 3.054 | 0.142 | 0.949 | 0.270 |\n| + output gate | 891 | 100 | 1 | 1 | 0 | 0 | 0 | 0 | static Gaussian | 8.731 | 0.825 | 3.191 | 0.153 | 0.954 | *0.284* |\n| + continuous-time encoding | 891 | 100 | 1 | 1 | 1 | 0 | 0 | 0 | static Gaussian | 8.445 | 0.814 | 3.139 | 0.151 | 0.954 | 0.277 |\n| + next-time head | 891 | 100 | 1 | 1 | 1 | 1 | 0 | 0 | static Gaussian | *6.873* | 0.507 | 2.043 | 0.247 | 0.852 | 0.220 |\n| + learned Gaussian | 891 | 100 | 1 | 1 | 1 | 1 | 1 | 0 | learned Gaussian | 6.884 | 0.491 | 1.944 | 0.067 | *0.890* | 0.264 |\n| + B-spline flow | 891 | 100 | 1 | 1 | 1 | 1 | 1 | 1 | B-spline flow | 7.813 | *0.472* | *1.912* | 0.161 | 0.855 | 0.278 |\n| - B-spline, + CNF-8 | 891 | 100 | 1 | 1 | 1 | 1 | 1 | 1 | CNF-8 | **6.386** | **0.414** | **1.586** | 0.088 | 0.876 | **0.315** |\n| - CNF-8, + MoG-2 | 891 | 100 | 1 | 1 | 1 | 1 | 1 | 0 | MoG-2 | 6.997 | 0.512 | 1.962 | **0.062** | 0.940 | 0.232 |\n\n\n| Model or changed ingredient | N | M | Residual draw | VRMSE↓ | CRPS↓ | WIS↓ | PIT-KS↓ | Cov90→.90 | r(σ,error)↑ |\n|---|---:|---:|---|---:|---:|---:|---:|---:|---:|\n| *Ingredient ablation, static Gaussian residual draw* ||||||||||\n| Absolute-level decoder | 891 | 100 | static Gaussian | 11.071 | 0.900 | 3.477 | **0.064** | **0.892** | 0.128 |\n| Carry-forward anchored residual | 891 | 100 | static Gaussian | 8.497 | *0.788* | *3.054* | *0.142* | 0.949 | 0.270 |\n| Anchored residual with output gate | 891 | 100 | static Gaussian | 8.731 | 0.825 | 3.191 | 0.153 | 0.954 | **0.284** |\n| Anchored residual plus continuous-time encoding | 891 | 100 | static Gaussian | *8.445* | 0.814 | 3.139 | 0.151 | 0.954 | *0.277* |\n| Continuous-time encoding plus next-time head | 891 | 100 | static Gaussian | **6.873** | **0.507** | **2.043** | 0.247 | *0.852* | 0.220 |\n| *Residual distribution family, sampled rollout* ||||||||||\n| G-Transformer baseline | 891 | 100 | static Gaussian | 8.706 | 0.588 | 2.512 | **0.060** | 0.803 | 0.155 |\n| PULSE Gaussian residual | 891 | 100 | learned Gaussian | *6.884* | 0.491 | 1.944 | *0.067* | **0.890** | 0.264 |\n| PULSE mixture of two Gaussians | 891 | 100 | learned mixture | 6.976 | 0.625 | 2.759 | 0.292 | 0.439 | 0.162 |\n| PULSE B-spline flow | 891 | 100 | learned B-spline flow | 7.813 | *0.472* | *1.912* | 0.161 | 0.855 | *0.278* |\n| PULSE continuous normalizing flow, 8 bases | 891 | 100 | learned CNF | **6.386** | **0.414** | **1.586** | 0.088 | *0.876* | **0.315** |\n\n\n| Past factual history supplied, k=6 | N | M | VRMSE↓ | Δ vs none↓ | 95% bootstrap CI |\n|---|---:|---:|---:|---:|---|\n| none | 75 | 8 | 9.246 | 0.000 | [0.000, 0.000] |\n| past treatments | 75 | 8 | 9.282 | 0.035 | [-0.077, 0.202] |\n| past death/release state | 75 | 8 | *7.509* | *-1.737* | [-4.304, -0.095] |\n| past death/release state, past other binary state | 75 | 8 | 7.510 | -1.736 | [-4.369, -0.071] |\n| past treatments, past death/release state, past other binary state | 75 | 8 | **7.488** | **-1.758** | [-4.334, -0.097] |\n\n\n| MIMIC-trained transfer to eICU HR/MAP, k=6 | N | M | MC-mean VRMSE↓ | Path VRMSE↓ | CRPS↓ | WIS↓ | PIT-KS↓ | Cov90→.90 |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|\n| Carry-forward + empirical changes | 300 | 100 | 1.147 | 1.506 | 0.493 | 0.366 | 0.124 | 0.743 |\n| Population mean + empirical training residuals | 300 | 100 | 1.344 | 1.968 | 0.561 | 0.378 | **0.038** | *0.884* |\n| G-Transformer + static Gaussian residuals | 300 | 100 | **1.005** | *1.491* | **0.404** | **0.279** | *0.050* | **0.914** |\n| PULSE MoG-4 | 300 | 100 | *1.028* | **1.461** | *0.425* | *0.301* | 0.051 | 0.870 |\n| PULSE B-spline | 300 | 100 | 1.088 | 2.110 | 0.469 | 0.339 | 0.114 | 0.978 |"
+ },
+ "createdAt": "2026-08-03T23:50:05.373Z",
+ "modifiedAt": "2026-11-19T16:45:58.576Z",
+ "url": "https://openreview.net/forum?id=seIHyi0c7e&noteId=Js86MAqX0o",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/seihyi0c7e/notes/omspu5xbs5.json added

+++ b/reviews/openreview/seihyi0c7e/notes/omspu5xbs5.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "OmsPu5Xbs5",
+ "replyTo": "WFEaTmzwGa",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you for your response. \n\nWe will of course add every point mentioned here to the final paper should the Area Chair decide to accept our paper. \n\nWith regard to reorganizing the paper, we are open to suggestions entirely and willing to rewrite anything as required, especially in terms of pairing motivations with design choices. Since we have already reached the page limit, we'd likely move some of the introduction/background paragraphs to later sections and silghtly rewrite them to fit the new structure, this is very achieveable. Given how much our arachitecture has changed in relation to G-Transformer, we're not sure that a more contrastive structure (\"and its relationship to G-Transformer\") would be feasible, as the text would end up mentioning the existing architecture many times only to state that it doesn't have the relevant component. However, we would definitely be able to add a single combined paragraph of a few sentences that clarifies the distinction that is our contribution and the retained elements from G-Transformer that represent the existing state of the art. \n\nWould this be agreeable? \n \nWe're eager to publish our work and are as such willing to spend significant effort in updating/rewriting text or re-running experiements for the camera-ready version if this could raise one of the reviewers' ratings or otherwise sway the Area Chair's accept/reject decision.\n\n\nAs an example, this is a first draft for a potential paragraph about the distinctions and retentions from G-Transformer:\n\nPULSE retains G-Transformer's (Xiong et al. 2024) well-motivated multi-decoder factorization: separate continuous and categorical variables, next-step prediction, treatments and covariates as history entries, and representation learning; we've reimplemented these aspects as faithfully as we could, based on the paper by Xiong et al (2024). In addition to publishing this code, our main architectural contributions include covariance-grouped decoders, continuous-time encodings, observation gates, next-measurement timing, and carry-forward-anchored residuals. Much of the innovation in this work comes in the form of new output heads: The basic probabilistic model outputs Gaussian parameters $\\mu$ and $\\sigma$; further variants add a second gaussian to form a mixture-of-gaussians output head, B-spline based neural flows, or a continuous normalizing flow. Both flows, as well as the gaussian outputs, are conditioned on the core model's last hidden state through an MLP. Our covariance-based grouping of variables follows our original setup with physiologically inspired manual grouping that already improved efficiency while remaining competitive in VRMSE and distributional metrics.\n\n\nRegarding the model description, we do already attempt to describe the architecture in section 3, however we could go into more detail on the \"backbone\" model, for example, the factorization could be slightly shortened with reference to the g-transformer paper to make room for this text:\n\nFrom an architectural perspective, PULSE uses one causally masked Transformer decoder per covariate group, followed by variable-specific output heads. Covariance grouping is fitted on training data using correlations among variable levels, one-step changes, and carry-forward residuals; every decoder still receives the full patient history. History includes observation masks, time since each variable was last measured, and a continuous encoding of absolute ICU hour and inter-event time using raw, log, and sinusoidal features. Separate heads predict the probability and timing of the next measurement. During rollout, these outputs determine which generated values enter history and when the event clock advances. Binary patient state is predicted before continuous physiology. Continuous predictions are anchored at the most recent observed or simulated value:\n\n$$\n\\mu_{v,t+\\Delta t}=c_{v,t}+g_{v,t}\\Delta t\\,\\delta_{v,t},\n$$\n\nwhere $\\delta_{v,t}$ is a bounded residual rate and $g_{v,t}\\in(0,1)$ is a learned update gate. CNF-8 maps hidden state jointly to location, scale, and eight amplitudes, centres, and positive widths defining a scalar flow. B-spline head outputs location, scale, and 23 logits whose softmaxed cumulative increments define 24 monotone control-point heights for a cubic B-spline with fixed knots.\n\n\n\n\nIf there are any other questions that keep this paper in the borderline rejection area or if any of the existing questions or weaknesses seem unaddressed, we'd love to clarify these as well."
+ },
+ "createdAt": "2026-08-03T13:26:19.173Z",
+ "modifiedAt": "2026-11-19T16:45:58.626Z",
+ "url": "https://openreview.net/forum?id=seIHyi0c7e&noteId=OmsPu5Xbs5",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/seihyi0c7e/notes/rrmi2clijg.json added

+++ b/reviews/openreview/seihyi0c7e/notes/rrmi2clijg.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "rRMi2clIJg",
+ "replyTo": "cSIQ5dXhRE",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "With the previous comment concisely attempting to address every weakness and question, we'd like to go into more detail on the questions specifically:",
+ "comment": "Application scenarios:\n\nThis is indeed an important question. We submitted our work to the applications track because it applies machine learning to medical data without creating entirely novel foundational mathematical concepts; our work is still not applicable clinically, integrating it and even understanding the needs would be a decade-long process. However our inital thoughts are: The primary immediate application is synthetic data generation and the typical uses that come with this - privacy, bias measurement and mitigation, improved downstream model performance with steerable detailed data construction. In general, having an uncertainty-quantifying, patient-state-dependent simulator that is clinically verified and tested would enable several highly desirable use cases such as predictive dose titration, counterfactual visualization (to be able to show patient what their future will likely look like in the charts with/without treatment), resource allocation (such as predicting with specified certainty whether a test is going to be uneventful, or predicting unplanned admissions or emergency treatment requirements). Such a simulator is very far from what our work can claim here, but without our work, which serves as an initial attempt at building a simulator, it would be impossible to ever test and evaluate clinically. Our impression of existing work is that often an uncertainty quantification is entirely missing from machine learning-enabled tools, forcing clinicians to assume high model uncertainty in every scenario, or otherwise compelling them to trust the model more than it should be trusted.\n\n\n\"good\" trajectory:\n\nWe appreciate this question and it is something we have spent considerable time investigating. An exploratory narrative review of existing literature points to no particular measure or quality that singularly identifies a good trajectory, and especially once probabilistic data enters the picture, many of the existing metrics disagree with eachother, so that with existing methods, only an aggregate evaluation across multiple scores can attempt to describe what is a good trajectory. Because the existing literature, however, does not specifically model variance changing over time, little attention has thus far been paid to distributional metrics and the focus was mainly on RMSE, which we attempted to show is not an ideal metric as even the best existing models are easily beaten by naive model-free policies. Our models nonetheless represent an improvement in this metric while also improving on the to us more interesting and important distributional scores. They are more important to us because, one of our core motivations being synthetic data generation, we want the model’s output to vary in such a way that output is realistic at a population level AND at the individual level. That being said, defining a qualitative and quantitative measure for trajectory quality is ongoing research and seems to us to be an unsolved problem. We plan to work on this particular issue before further developing PULSE after the first publication.\n\n\n\nwhich aspects of the trajecotry can be well-modeled:\n\nThis is another very difficult problem and in fact a defining motivation for our work - we found that very few examples in existing literature try to separate aleatoric and epistemic uncertainty. PULSE represents our attempt at defining what part of the uncertainty can be modeled by for once including uncertainty explicitly in the objective and the model’s outputs. If your question is aimed more at the specific types of noise that would be random or explainable, we currently assume that mostly random aspects include measurement error from environmental influences(as an example, a thunderstorm outside might affect the patient’s heart rate or BP), a significant portion of measurement timing (but not all of it, the existence of tests/measurements in the records is often quite informative), absolute timing of ICU admission. Arguably, a vast portion of patient-specific individualities are quite random as well when looking at population-level effects. However, an important aspect to our interpretation is that even an essentially random intervention does often nonetheless not follow a normal distribution. Modeling these distributions would thus also serve a synthetic data generator as the simplest application but, thinking further in research progress, even visualizations and digital twin-like applications would benefit significantly. We regret not being able to precisely answer this question, but we hope this reply might establish a degree of common understanding."
+ },
+ "createdAt": "2026-07-30T21:20:51.644Z",
+ "modifiedAt": "2026-11-19T16:45:58.764Z",
+ "url": "https://openreview.net/forum?id=seIHyi0c7e&noteId=rRMi2clIJg",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/seihyi0c7e/notes/t4qgqw3aar.json added

+++ b/reviews/openreview/seihyi0c7e/notes/t4qgqw3aar.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "t4qGqw3aAR",
+ "replyTo": "JaX5dYBQV3",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We're still waiting on some final experiments to finish for the ablation tables and will post these as soon as possible today to answer both of the questions. We apologize for the delay on these tables, we've been working hard to get them finished within the review period.\n\nWe would like to expressly thank the reviewer for the high rating and the acknowledgement of our motivation, easy-to-follow factorization and strong evaluation.\n\nOn the weaknesses, we'd like to clarify - and perhaps this would have to be rephrased in the paper to be more clear as well: We don't claim to have a fully solved, clinically viable simulator here. Taking this work into a clinical setting would still require much work and especially clinical validation. Nonetheless we think this manuscript brings EHR prediction and/or simulation much closer to viability.\n\nWhile we wanted to report VRMSE as the most commonly reported metric, we do also disagree with it as a main metric specifically because these naive baseline policies already outperform the state of the art. This is why we have added multiple probabilistic metrics, and we are especially proud of our r(sigma, err) stat - the model much more correctly predicts its own uncertainty, which is, in our opinion, an important aspect of our contribution. We nontheless agree that even on the distributional metrics the model-less baselines and even the gaussian, non-flow-based variants are actually fairly competitive. The point is, however, that evidence very much supports the idea that the probabilistic approach (i.e. predicting any aspect of the distributional shape at all for the first time) is valuable here. We do agree that more work is needed to further improve the flow-based models. \n\nWe'd be happy to rephrase any of the claims into a softer version, though, if this helps in giving the paper better credibility towards publication.\n\nWe investigated the flow-based variants because in visual inspection they seem to be significantly better at predicting the sometimes very unique shapes of the training distribution (which also transfers to the test set), but it's hard to find a metric that really shows this consistently. Finding the best way to measure this trajectory-level distributional realism is part of the work we still plan to complete and seems to be an active problem in the field."
+ },
+ "createdAt": "2026-08-03T11:59:50.116Z",
+ "modifiedAt": "2026-11-19T16:45:58.879Z",
+ "url": "https://openreview.net/forum?id=seIHyi0c7e&noteId=t4qGqw3aAR",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/seihyi0c7e/notes/wfeatmzwga.json added

+++ b/reviews/openreview/seihyi0c7e/notes/wfeatmzwga.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "WFEaTmzwGa",
+ "replyTo": "gjXR2VFO7E",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer wjJE",
+ "content": {
+ "comment": "Thank you for the detailed responses. I appreciate the provided details in the response, and I think having them in the manuscript matter for reproducibility. I also appreciate the explanation and correction for scheduled sampling and limitations. \n\nGiven how much information the paper covers, I think reorganizing it would make it easier to follow. In particular, pairing each design choice with its motivation and its relationship to G-Transformer would help readers see the contributions more clearly."
+ },
+ "createdAt": "2026-08-03T05:37:44.105Z",
+ "modifiedAt": "2026-11-19T16:45:58.683Z",
+ "url": "https://openreview.net/forum?id=seIHyi0c7e&noteId=WFEaTmzwGa",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/seihyi0c7e/notes/xigif4ofpu.json modified

+++ b/reviews/openreview/seihyi0c7e/notes/xigif4ofpu.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair v3A3",
"content": {
- "metareview": "This paper proposes a patient-specific ICU EHR trajectory simulator and has reasonably thorough experimental results. Before the author/reviewer discussion period, reviews were mixed (1 accept, 2 borderline rejects) and reviewers raised concerns regarding clarity/exposition and relating the proposed method to G-transformer (for more details, see the reviews from reviewers Uw9K and wjJE). After the author/reviewer discussion period, reviews became slightly more positive but are still mixed (1 accept, 1 borderline accept, 1 borderline reject). The authors addressed much of the concerns (e.g., explaining how the proposed method is different from G-transformer, various clarity/exposition issue). I looked at the concerns from the borderline reject review and I think they have been adequately addressed by the authors. I am recommending that this paper be accepted."
+ "metareview": "This paper proposes a patient-specific ICU EHR trajectory simulator and has reasonably thorough experimental results. Before the author/reviewer discussion period, reviews were mixed (1 accept, 2 borderline rejects) and reviewers raised concerns regarding clarity/exposition and relating the proposed method to G-transformer (for more details, see the reviews from reviewers Uw9K and wjJE). After the author/reviewer discussion period, reviews became slightly more positive but are still mixed (1 accept, 1 borderline accept, 1 borderline reject). The authors addressed much of the concerns (e.g., explaining how the proposed method is different from G-transformer, various clarity/exposition issue). I looked at the concerns from the borderline reject review and I think they have been adequately addressed by the authors. I am recommending that this paper be accepted.",
+ "final_justification": "My meta-review already includes my updated justification."
},
"createdAt": "2026-07-21T21:52:59.476Z",
- "modifiedAt": "2026-11-18T15:26:12.996Z",
+ "modifiedAt": "2026-11-19T05:03:56.707Z",
"url": "https://openreview.net/forum?id=seIHyi0c7e&noteId=xIGif4OFPU",
"license": "CC-BY-4.0"
}