potentialpaper

PhysTTT: Accurate and Lightweight Cross-Domain Heart Rate Measurement with Test-Time Training

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 18:46 UTC · e01f7af9df5b ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,26 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "l4KbvGkQSw"
- }
- ],
- "title": "PhysTTT: Accurate and Lightweight Cross-Domain Heart Rate Measurement with Test-Time Training",
- "authors": [
- "Yancheng Yao",
- "Yifei Liu",
- "Shangwei Zhu",
- "Yu Wang",
- "Le Yuan",
- "Shaohua Liu"
- ],
- "abstract": "Remote photoplethysmography (rPPG), a contactless technology for measuring physiological signals, holds significant promise for smart healthcare and affective computing. However, a key challenge for existing deep learning methods is the paradox between maintaining high measurement accuracy and ensuring low computational cost, especially in cross-domain scenarios. To address this, we propose PhysTTT, a novel and lightweight framework for heart rate measurement that integrates multiple 1D-CNNs with residual structures and a Test-Time Training (TTT) layer. Multi-time frame differences fusion and 1D-CNNs extract spatio-temporal features from facial video sequences by modeling subtle brightness variations, the TTT layer compresses the context information into a learnable vector space, enhancing the temporal modeling capability. Crucially, the TTT mechanism enables the model to adapt to unseen data distributions during inference, significantly boosting cross-domain generalization. Extensive experiments demonstrate that PhysTTT achieves state-of-the-art accuracy in both in-domain and cross-domain evaluations, offering an optimal balance of high performance, strong generalization, and low computational cost. Our code is publicly available at https://anonymous.4open.science/r/PhysTTT-B605/.",
- "year": 2026,
- "venue": "ICLR 2026 submission",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "40137d08-84bb-4847-a7ef-d54a45fb0662"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,16 @@
+{
+ "title": "PhysTTT: Accurate and Lightweight Cross-Domain Heart Rate Measurement with Test-Time Training",
+ "authors": [
+ "Yancheng Yao",
+ "Yifei Liu",
+ "Shangwei Zhu",
+ "Yu Wang",
+ "Le Yuan",
+ "Shaohua Liu"
+ ],
+ "abstract": "Remote photoplethysmography (rPPG), a contactless technology for measuring physiological signals, holds significant promise for smart healthcare and affective computing. However, a key challenge for existing deep learning methods is the paradox between maintaining high measurement accuracy and ensuring low computational cost, especially in cross-domain scenarios. To address this, we propose PhysTTT, a novel and lightweight framework for heart rate measurement that integrates multiple 1D-CNNs with residual structures and a Test-Time Training (TTT) layer. Multi-time frame differences fusion and 1D-CNNs extract spatio-temporal features from facial video sequences by modeling subtle brightness variations, the TTT layer compresses the context information into a learnable vector space, enhancing the temporal modeling capability. Crucially, the TTT mechanism enables the model to adapt to unseen data distributions during inference, significantly boosting cross-domain generalization. Extensive experiments demonstrate that PhysTTT achieves state-of-the-art accuracy in both in-domain and cross-domain evaluations, offering an optimal balance of high performance, strong generalization, and low computational cost. Our code is publicly available at https://anonymous.4open.science/r/PhysTTT-B605/.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}