potentialpaper

DistillAlign: Coordinating Mode Covering and Mode Seeking in Autoregressive Video Distillation

Anonymous authors

ICLR 2027

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Existing autoregressive video distillation methods commonly adopt a Distribution Matching Distillation (DMD)-based multi-stage pipeline. However, they typically decouple the initialization and DMD stages—which then pursue different target distributions—and judge the intermediate student mainly by visual scores such as VBench. In this paper, we revisit this design from a distributional perspective. Given the mode-seeking nature of the distribution matching loss, a good initialization should match the mode coverage of the target DMD teacher, rather than merely pursuing high quality. To analyze this, we introduce a distributional evaluation protocol that measures precision and coverage between student and teacher distributions in a shared latent space. It exposes differences hidden by visual scores: some initializations reach high precision but low coverage, leading to suboptimal refinement, while mode-covering ones preserve broader support. Furthermore, even when the target distributions are aligned, DMD's reverse-KL objective can still drive the student toward high-probability teacher regions in late training, reducing coverage and diversity. To address this, we propose joint distillation, which combines DMD's mode-seeking objective with a Consistency Distillation-based mode-covering constraint. Experiments show that our method improves generation quality, coverage, and diversity; notably, even with a Wan-1.3B DMD teacher, it outperforms baselines refined with Wan-14B, underscoring the importance of distributional alignment in autoregressive video distillation. Code, data, and models will be publicly released.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
20 Aug 2026ICLR 2027 (under review)submittedICLR 2027Under reviewreviews ↓[1]PDF[1]
Missing a version?

ICLR 2027

Under review · 3 reviews · OpenReview

Updated 25 Nov 2026, 10:35 UTC.

Reviewer mpmnOpenReview ↗
Rating
3/4
Confidence
2/4
Soundness
3/3
Presentation
3/3
Informativeness
2/3
Read review
Summary

DistillAlign studies distribution mismatch and mode collapse in multi-stage autoregressive video distillation. It introduces a teacher-normalized evaluation protocol using V-JEPA2 features to measure precision, coverage, and diversity. Building on the Causal Forcing pipeline, it aligns the initialization data with the target DMD teacher and replaces pure DMD refinement with a joint DMD-CD objective, where DMD improves fidelity and CD preserves distribution coverage. Experiments on Wan2.1-T2V show improved VBench scores, coverage, and diversity. Controlled teacher-source swaps, loss-weight ablations, and training-dynamics analyses support the effectiveness of distribution alignment and joint distillation.

Strengths
  1. Clear motivation. The paper clearly identifies two issues in autoregressive video distillation: distribution mismatch between initialization and DMD refinement, and late-stage coverage degradation caused by the mode-seeking behavior of DMD.
  2. Useful distributional analysis. The teacher-normalized evaluation protocol, together with V-JEPA2 features, precision, coverage, and diversity metrics, provides information that is complementary to VBench and helps analyze distribution coverage during distillation.
  3. Simple objective with competitive results. The proposed joint objective is conceptually simple. In the reported setting, the weak variant with a 1.3B DMD teacher outperforms the listed 14B-teacher distilled baselines in total VBench and coverage.
Weaknesses
  1. The paper lacks comparisons of training time and GPU memory across different methods.
  2. The generalization is limited, as experiments are conducted only on Wan2.1-T2V.
  3. Measuring distribution coverage in the V-JEPA2 feature space may introduce bias, and the robustness of the metrics under different settings is unclear.
Questions for the authors
  1. Will combining two losses significantly increase the time and memory overhead of distillation?
  2. Does the method generalize to other architectures, such as Wan2.1-I2V or CogVideoX?
7 comments
Authors · CommentOpenReview ↗

Official Comment by Authors

Thank you for the constructive review. We organize your comments into individual questions and respond to them in order below.

mpmn-Q1: Does combining the losses significantly increase distillation time and memory?

[Training time and computation]

In the default DMD stage, the student is updated once per five critic updates, and joint distillation adds computation only to student updates. We report individual updates and a full cycle (five critic updates plus one student update) below. FLOPs are reported per GPU. Measurements were obtained on a single node with eight A100 GPUs.

Method Training time Computation per GPU
Student update Critic update Full cycle Student update Critic update Full cycle
Pure DMD 49.35 s 63.69 s 367.67 s 6.392 PFLOPs 7.862 PFLOPs 45.701 PFLOPs
Joint Distillation 75.28 s 64.57 s 397.99 s 9.305 PFLOPs 7.862 PFLOPs 48.613 PFLOPs
Increase 52.50% 1.40% 8.24% 45.60% 0% 6.37%

Full-cycle time increases by 8.24% and FLOPs by 6.37%, which we consider acceptable overhead.

[Memory]

We report peak allocated GPU memory, time-averaged device memory usage, and peak device memory usage below.

Method Peak allocated GPU memory Time-averaged device memory Peak device memory
Pure DMD 39.65 GiB 41.62 GiB 59.30 GiB
Joint Distillation 44.63 GiB 45.23 GiB 69.08 GiB

Peak device-memory usage is 69.08 GiB, within the memory capacity of an 80-GB A100.

Authors · CommentOpenReview ↗

Official Comment by Authors

mpmn-Q2: Does the method generalize to other architectures, such as Wan2.1-I2V or CogVideoX?

Yes. We evaluated CogVideoX1.5-5B and Wan2.2-TI2V-5B. Starting from a Causal Forcing baseline trained on OpenVid, we progressively add teacher-source alignment and joint distillation. For each architecture, both the DMD teacher and the reference teacher for distribution metrics are its corresponding base model.

The results are reported below.

Model / Setting VBench Distribution
Total Quality Semantic Precision Coverage
CogVideoX1.5-5B (base model) 82.67 83.41 79.71 / /
baseline 82.32 83.11 79.16 0.68 0.43
+ Teacher-source alignment 82.41 83.18 79.33 0.75 0.52
+ joint distillation 82.46 83.22 79.42 0.79 0.59
Wan2.2-TI2V-5B (base model) 83.19 84.53 77.83 / /
baseline 83.44 84.87 77.72 0.81 0.49
+ Teacher-source alignment 83.81 85.23 78.13 0.74 0.63
+ joint distillation 83.90 85.31 78.26 0.76 0.66

The gains in VBench scores and coverage support the applicability of our method to both architectures.


mpmn-W1: How reliable is V-JEPA2-based coverage, and how robust are the conclusions to evaluation settings?

[Accuracy]

Coverage depends on relative distances in V-JEPA2 feature space. To validate this ordering, we plan a study of 50 anonymized comparisons, each containing a reference video and two candidates with a clear preference. Thirty raters would assess 10 questions each, yielding six independent ratings per question. We would compare feature-distance preferences with human preferences.

Agreement on clear-preference pair Agreement rate
46/50 92.00%

[Robustness]

Using the DMD stage as an example, we fix the initialization checkpoint and vary the training seed. The table below reports means and standard deviations.

Initial coverage (%) After-DMD coverage (%) Δ coverage (%) Δ precision (%) Δ diversity (%)
61.33 57.03 ± 1.66 3.83 ± 0.75 0.31 ± 0.64 1.16 ± 0.58

The standard deviations of the changes in coverage, precision, and diversity are all below 1%.

Authors · CommentOpenReview ↗

Seeking Further Feedback

Thank you again for your thoughtful review and constructive feedback. As the discussion phase is coming to a close, we would greatly appreciate any further thoughts on our rebuttal. If any concerns remain or additional clarification would be helpful, please feel free to let us know, and we would be happy to address them. If the main concerns have been sufficiently addressed, we would sincerely appreciate your consideration of updating your assessment accordingly.

Thank you again for your time and consideration.

Reviewer EiEoOpenReview ↗
Rating
3/4
Confidence
4/4
Soundness
2/3
Presentation
3/3
Informativeness
2/3
Read review
Summary

This paper studies the degradation of diversity and motion dynamics in autoregressive video diffusion distillation. It aligns the initialization with the target teacher and combines Distribution Matching Distillation (DMD) with Consistency Distillation (CD) to balance mode seeking and mode covering. The authors introduce a coverage evaluation protocol based on V-JEPA2 features and report improvements in coverage, diversity, and VBench scores through teacher-source swaps and ablation studies on Wan2.1.

Strengths
  1. A useful distributional perspective. The teacher-source swaps and coverage analysis show that initialization's visual quality alone does not predict subsequent distillation performance, while the initialization method is important. This provides useful guidance for understanding diversity degradation in autoregressive video distillation and selecting an initialization strategy.
  2. Practical value of joint training. With matched initialization, adding CD improves coverage from 0.53 to 0.69 while maintaining a slightly higher VBench score. This supports its value as a simple training modification that better balances diversity preservation and quality.
Weaknesses
  1. Insufficient evidence of incremental novelty. Initialization method like CD/PiecewiseFlow followed by DMD is already established in the community, and HiAR addresses motion degradation through coverage-oriented constraints. Without direct comparisons or a clearer distinction from these approaches, I find it difficult to assess the substantive advance over prior work.
  2. Insufficient validation of the claimed benefits. The VBench gain from an initially poor student do not clearly establish perceptual improvements. Together with evaluation limited to Wan2.1, this weakens confidence in the interpretation and generality of the results.
Questions for the authors
  1. How does the proposed joint constraint differ mechanistically from HiAR and related methods?
  2. Relative to existing pipelines that initialize with PiecewiseFlow or CD before DMD, is the additional contribution primarily teacher-source alignment, joint CD training, or their combination? How do the existing ablations support this attribution?
  3. VBench may not fully capture perceptual quality and can be susceptible to metric optimization without corresponding quality gains. Are there finer-grained motion metrics or human evaluations supporting the overall comparisons and ablation conclusions?
  4. For Figure 6 (left), what evidence distinguishes increased coverage due to general improvements in generation ability from a mode-covering effect specific to CD? The low score may derived from the low generation performance in the initialization stage, when DMD/CD involved, the coverage may improve with the generation performance improved.
  5. Is there supporting evidence from newer models such as MiniMax-H3/LTX-2, or other accessible models?
3 comments
Authors · CommentOpenReview ↗

Official Comment by Authors

Thank you for the constructive review. We organize your comments into individual questions and respond to them in order below.

EiEo-Q1: Difference from HiAR?

HiAR also uses a similar formulation combining FKL-style and RKL-style objectives, but:

  1. Its FKL-style and RKL-style objectives target different teacher distributions. The FKL-style ODE constraint uses trajectories from the Wan2.1-1.3B base model, whereas the RKL-style DMD constraint uses Wan2.1-14B. DistillAlign explicitly studies and addresses this teacher-source mismatch.

  2. In addition, we introduce a distribution evaluation protocol to study how FKL-style and RKL-style objectives should be connected and combined, and how distributions evolve across distillation stages (see EiEo-Q2).


EiEo-Q2: What are the contributions?

Our work focuses on rethinking autoregressive video diffusion distillation from a distributional perspective, with three main contributions:

  1. A distribution evaluation protocol to assess how well two video distributions match. Corresponding experiments are reported in Tables 2 and 6, Sec. 4.4, and YxHR-Q1.

  2. Teacher-source alignment: How should FKL-style and RKL-style objectives be connected? Corresponding experiments are reported in Sec. 3.2.

  3. Joint distillation: How should FKL-style and RKL-style objectives be combined? Corresponding experiments are reported in Secs. 3.3 and 4.3.

The Methodology section presents the central findings; subsequent sections provide detailed ablations.


EiEo-Q3: Limitations of Current Metrics

We extend the main comparisons and ablations with perception- and motion-related metrics from VMBench [1] and user studies. In each study, 30 participants rank anonymized outputs for 30 cases on visual quality(VQ), semantic alignment(SA), and temporal coherence(TC). We weight and normalize the rankings to obtain the final scores.

The results are reported below.

PAS: Perceptible Amplitude Score; TCS: Temporal Coherence Score; MSS: Motion Smoothness Score.

[Main Comparison]

Method VBench Distribution VMBench User study
Total Quality Semantic Precision Coverage Diversity PAS TCS MSS VQ SA TC
Self-Forcing 84.21 85.04 80.87 0.78 0.53 1.269 24.13 97.74 90.38 44.78 45.44 44.19
Causal-Forcing 84.38 85.47 80.01 0.61 0.29 1.250 25.81 97.93 90.26 47.41 48.7 47.41
DistillAlign(1.3B teacher) 84.54 85.61 80.28 0.77 0.59 1.305 25.93 97.88 93.21 52.48 51.74 53.3
DistillAlign(14B teacher) 84.83 85.92 80.47 0.79 0.69 1.304 26.28 98.14 92.07 55.33 54.11 55.11

[Main Ablation]

1. on Joint distillation (14B DMD teacher)

Method VBench Distribution VMBench User study
Total Quality Semantic Precision Coverage Diversity PAS TCS MSS VQ SA TC
w/ JD (λ = 0.01) 84.83 85.92 80.47 0.79 0.69 1.304 26.28 98.14 92.07 58.44 54.89 56.5
w/o JD 84.74 85.78 80.54 0.72 0.54 1.292 25.65 97.83 91.56 41.56 45.11 43.5

2. on Teacher-source alignment (without joint distillation)

the unaligned variant uses Wan2.1-1.3B as its initialization source.

Method VBench Distribution VMBench User study
Total Quality Semantic Precision Coverage Diversity PAS TCS MSS VQ SA TC
Aligned 84.74 85.78 80.54 0.72 0.54 1.292 25.65 97.83 91.56 61.56 63.56 58.67
Unaligned 84.16 85.38 79.29 0.69 0.43 1.290 24.61 97.56 90.58 38.44 36.44 41.33

The supplementary material includes qualitative examples for visual inspection.

[1] VMBench: A Benchmark for Perception-Aligned Video Motion Generation. Xinran Ling et al. ICCV 2025, pp. 13087–13098.

Authors · CommentOpenReview ↗

Official Comment by Authors

EiEo-Q4: How do you distinguish low coverage caused by weak generation from a genuine distribution mismatch?

Weak generation can lower measured coverage through blur or artifacts, even when a model reaches the correct semantic region. We mitigate this confound with teacher-normalized refinement: all initializers use the same re-noising strength, refinement teacher, and denoising schedule before evaluation in V-JEPA2 space. This reduces differences in low-level image quality and emphasizes semantic support.

See Sec. 4.4 for the corresponding experiments.

YxHR-Q2.2 also reports the results for pure noise under this evaluation protocol.


EiEo-Q5: Does the method also work on other architectures like MiniMax-H3 or LTX-2?

Given the rebuttal time and compute constraints, we evaluated the smaller CogVideoX1.5-5B and Wan2.2-TI2V-5B models.

Starting from a Causal Forcing baseline trained on OpenVid, we progressively add teacher-source alignment and joint distillation. For each architecture, both the DMD teacher and the reference teacher for distribution metrics are its corresponding base model.

The results are reported below.

Model / Setting VBench Distribution
Total Quality Semantic Precision Coverage
CogVideoX1.5-5B (base model) 82.67 83.41 79.71 / /
baseline 82.32 83.11 79.16 0.68 0.43
+ Teacher-source alignment 82.41 83.18 79.33 0.75 0.52
+ joint distillation 82.46 83.22 79.42 0.79 0.59
Wan2.2-TI2V-5B (base model) 83.19 84.53 77.83 / /
baseline 83.44 84.87 77.72 0.81 0.49
+ Teacher-source alignment 83.81 85.23 78.13 0.74 0.63
+ joint distillation 83.90 85.31 78.26 0.76 0.66

The gains in VBench scores and coverage support the applicability of our method to both architectures.

Authors · CommentOpenReview ↗

Seeking Further Feedback

Thank you again for your thoughtful review and constructive feedback. As the discussion phase is coming to a close, we would greatly appreciate any further thoughts on our rebuttal. If any concerns remain or additional clarification would be helpful, please feel free to let us know, and we would be happy to address them. If the main concerns have been sufficiently addressed, we would sincerely appreciate your consideration of updating your assessment accordingly.

Thank you again for your time and consideration.

Reviewer YxHROpenReview ↗
Rating
3/4(+1)
Confidence
3/4(+1)
Soundness
3/3(+1)
Presentation
3/3(+1)
Informativeness
2/3
Read review
Summary

This paper argues that, in the DMD-based distillation of AR video models, the initializer should be judged by how well it covers the DMD teacher's distribution, rather by VBench. The paper measures this by re-noising initializer outputs to ρ=0.9\rho=0.9, then denoising them with a fixed teacher, and finally computing k-NN precision and coverage on V-JEPA2 features. They also add a CD loss to DMD to keep coverage late in training.

Strengths
  1. The proposed question is practical. The paper shows in the table 2 that, with the DMD teacher fixed, matching the initialization data gives higher coverage after DMD, for both of the teachers.
  2. In table 6, they show that, raw coverage can be misleading, because the ODE initializater has much lower raw coverage than Causal DMD but ends higher after DMD.
  3. The proposed joint loss is simple and effective. In table 5, it keeps higher coverage than pure DMD at every ckpt after step 0. At step 2500, it leads on VBench in both settings.
Weaknesses
  1. Does coverage explain the gains? The table 2 shows that matching can help, but changing the training data can change more than coverage. So,,it does not show that coverage is the reason. Table 6 fixes the data and teacher, but compares only five pipelines. Four of them (B-E) have post-DMD VBench scores between 84.48 and 84.74. Coverage is estimated from 256 videos across 16 prompts, and I could not find uncertainty estimates or results across the training seeds. I would suggest a simple check: running the same DMD stage from several Causal CD ckpts in Figure 6 (already shown coverage 0.02 to 0.66) would show whether final quality follows initializer coverage.
  2. What does the normalized coverage measure? At ρ=0.9\rho=0.9 the initializer latent is scaled by 0.1. Then, a strong teacher denoises it. It is unclear to me which teacher is it. The section 3.1 says it differs from the reference teacher, while the appendix B says both Wan-14B and the shared 1.3B model... If the same model denoises and makes the reference videos, the coverage may partly reflect the teacher. This does matter, because the ODE vs CausalDMD ranking in the table 6 is 0.326 vs 0.324. Besides, it seems the initializers are re-noised but models after DMD are not, so the claim on line 194 that '... DMD generally reduces coverage ...' actually compares numbers from two procedures that are different. I believe some ablations are necessary here.
  3. When does the CD term help visual quality, and where do the baselines come from? The λ=0\lambda=0 runs in Table 5 and Table 8 look good, as they compare against CD followed by pure DMD. But, after reading the table 4 and 7, I found the VBench gain over pure DMD is very small at the best ckpts. Besides, how the best ckpt is picked is not stated here. If the best is picked using the reported VBench or coverage, then the numbers might be optimistic. For baselines, there might be some inconsistencies. The causal forcing has 84.38 and 0.29 in table 3, while 83.89 and 0.435 for the 'original causal forcing setting' in table 1 and table 2. I cannot tell whether the baselines are from public or re-trained. This can be the point because the claim that the weak variant can beat all 14B teacher baselines will ground on it. Finally, authors listed some other ways to add a mean-seaking term to DMD in the appendix (e.g., rCM, HiAR, BiWM, Mode Seeking meets Mean Seeking), but none of them is further compared. Adding (some of) them can be helpful.
Questions for the authors
  1. If you run DMD from several Causal CD ckpts in figure 6 with different coverage, does final quality follow initializer coverage? Could you add error bars for the Table 2?
  2. For each row in table 2 and 6, which model is the normalization teacher and which is the reference teacher? What coverage can pure noise get with the same procedure, and does coverage still drop after DMD if DMD models are re-noised as well?
  3. How is the best ckpt choosed? Why does the trend in Table 8 differ from Table 5 given that the weak setting (table 8) mirrors table 5. i.e., joint training leads pure DMD on VBench at every ckpt after initialization (table 5), while in table 8, it falls behind at step 500, 1000, and 1500 despite the higher coverage. Were baselines in table 3 got retrained? Are there any reasons that the causal forcing numbers differ between table 3 and tables 1,2?
7 comments
Authors · CommentOpenReview ↗

Official Comment by Authors

Thank you for the constructive review. We organize your comments into individual questions and respond to them in order below.

YxHR-Q1: When DMD is initialized from different Causal-CD checkpoints in Fig. 6, does final quality improve with initializer coverage?

We ran DMD from the Causal-CD checkpoints in Fig. 6, whose coverage increases monotonically with training steps. The final results are reported below.

VBench Distribution
CD init step Total Quality Semantic Precision Coverage Diversity
0 84.48 85.36 80.97 0.691 0.348 1.247
500 84.51 85.44 80.8 0.6302 0.3555 1.2762
1000 84.68 85.51 81.35 0.5781 0.3828 1.2931
1500 84.63 85.56 80.89 0.5938 0.4623 1.2906
2000 84.79 85.73 81.02 0.6602 0.5158 1.3026
2500 84.83 85.92 80.47 0.7914 0.6951 1.3042

It can be seen that final coverage and VBench scores increase approximately monotonically, following the trend in initializer coverage. We also observe that precision initially declines and then recovers.


YxHR-Q2.1: Which normalization and reference teachers are used in Tables 2 and 6?

In Tables 2 and 6, both the normalization teacher and the reference teacher match the target DMD teacher, i.e., in Table 2, this is the teacher listed in the second column; in Table 6, both teachers default to Wan2.1-14B. We will clarify this in the revised manuscript.

YxHR-Q2.2: How do pure noise and randomly initialized controls score under the evaluation protocol?

We evaluate three cases, each with and without teacher-normalized refinement:

Gaussian latent noise || a randomly initialized few-step generator || a randomly initialized few-step generator trained with DMD.

Input W/o refinement W/ refinement
Precision Coverage Diversity Precision Coverage Diversity
Gaussian noise 0 0 1.021 0.0039 0.0039 1.3424
Random init. 0 0 1.0205 0.0078 0.0078 1.3382
Random init. + DMD 0 0 1.0199 0.0234 0.0195 1.3392

Even after teacher-normalized refinement, precision and coverage remain near zero for these controls because of the large distribution mismatch.

YxHR-Q2.3: Does coverage still drop after DMD if DMD models are re-noised as well?

Yes. We re-evaluated checkpoints trained with the 1.3B and 14B DMD teachers after re-noising and teacher refinement. Coverage still declines as DMD training progresses.

DMD teacher / Step 0 500 1000 1500 2000 2500
14B teacher 0.7124 0.7183 0.7105 0.6988 0.6797 0.6484
1.3b teacher 0.6133 0.6094 0.6133 0.5898 0.5820 0.5742
Authors · CommentOpenReview ↗

Official Comment by Authors

YxHR-Q3.2: Why do Tables 5 and 8 show different training trends?

The paper reports only the first 2,500 training steps. We extended training with both the 14B and 1.3B teachers to examine the longer-term trends below.

[14B teacher]

VBench Distribution
step Total Quality Semantic Precision Coverage Diversity
0 82.6 84.18 76.27 0.69 0.66 1.319
500 84.6 85.87 79.53 0.82 0.67 1.305
1000 84.78 85.85 80.52 0.80 0.68 1.304
1500 84.83 85.92 80.47 0.79 0.69 1.304
2500 84.27 85.26 80.32 0.79 0.68 1.307
3000 84.25 85.23 80.33 0.81 0.66 1.302
3500 84.31 85.34 80.19 0.83 0.61 1.298

[1.3B teacher]

VBench Distribution
step Total Quality Semantic Precision Coverage Diversity
0 82.16 83.38 77.29 0.61 0.52 1.301
500 83.84 85.07 78.92 0.66 0.52 1.295
1000 84.17 85.38 79.29 0.69 0.51 1.292
1500 84.38 85.33 80.58 0.72 0.53 1.297
2500 84.54 85.61 80.28 0.77 0.59 1.305
3000 84.41 85.48 80.13 0.76 0.59 1.301
3500 84.30 85.32 80.22 0.79 0.54 1.299

Both runs improve initially and then decline, but at different rates. One possible reason is that FKL-style CD constrains the flow map, whereas RKL-style DMD constrains the endpoint distribution. Combining these objectives may introduce instability, which is a limitation of our method. Nevertheless, our results still show that the combination of FKL and RKL can achieve higher quality and coverage.

YxHR-Q3.1: How is the final checkpoint selected?

Given the trends in YxHR-Q3.2, we select from checkpoints saved at regular intervals within a fixed training budget, rather than simply using the final checkpoint. Generation quality takes priority over distribution metrics, (although both typically peak at the same checkpoint.)

YxHR-Q3.3: Were the baselines in Table 3 retrained?

No. Table 3 uses the official released checkpoints, evaluated with settings aligned with Causal Forcing.

For a controlled comparison, we also retrained Causal Forcing and Self Forcing using their official recipes for 2,500 steps, selecting checkpoints as described in YxHR-Q3.1. Results are shown below; an asterisk (*) denotes a retrained baseline.

Method DMD teacher VBench Distribution
Total Quality Semantic Precision Coverage Diversity
Self-Forcing Wan2.1-14B 84.21 85.04 80.87 0.78 0.53 1.269
Causal-Forcing Wan2.1-14B 84.38 85.47 80.01 0.61 0.29 1.250
Self-Forcing * Wan2.1-14B 84.30 85.34 80.15 0.73 0.54 1.272
Causal-Forcing * Wan2.1-14B 84.45 85.46 80.37 0.71 0.46 1.265
DistillAlign(weak) Wan2.1-1.3B 84.54 85.61 80.28 0.77 0.59 1.305
DistillAlign(full) Wan2.1-14B 84.83 85.92 80.47 0.79 0.69 1.304

YxHR-Q3.4: Why do the Causal Forcing results differ between Table 3 and Tables 1–2?

Tables 1–2 report toy experiments built on the Causal Forcing pipeline without joint distillation, isolating the effect of matching the data and teacher distributions. Table 3 reports the full method, including the subsequent joint distillation stage.

The corresponding settings also appear in the λ = 1 and λ = 0 ablations in Table 4.

Authors · CommentOpenReview ↗

Seeking Further Feedback

Thank you again for your thoughtful review and constructive feedback. As the discussion phase is coming to a close, we would greatly appreciate any further thoughts on our rebuttal. If any concerns remain or additional clarification would be helpful, please feel free to let us know, and we would be happy to address them. If the main concerns have been sufficiently addressed, we would sincerely appreciate your consideration of updating your assessment accordingly.

Thank you again for your time and consideration.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…

This paper is under review