potentialpaper

What Does “No Contamination Detected” Certify? Dose-Calibrated Detection Limits for Benchmark Contamination

Anonymous authors

ICLR 2027

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. We show that negative contamination audits require calibrated detection sensitivity, and introduce dose-calibrated evaluation to quantify what contamination detectors can rule out.

Abstract. Benchmark contamination threatens the reliability of large language model evaluation, yet a negative contamination audit is difficult to interpret without knowing the sensitivity of the detector being used. Existing audits often report “no evidence of contamination” without quantifying what amount of exposure would have been detectable.

We introduce CONTAM-LADDER, a controlled framework for calibrating contamination detection sensitivity. CONTAM-LADDER constructs models with known contamination exposure levels through dose-controlled training and evaluates detectors through power curves rather than binary decisions. This enables estimating minimum detectable doses (MDDs) and determining when a negative audit result is informative versus inconclusive.

Across 36 contamination cells spanning model scales, benchmarks, exposure depths, and surface forms, we reveal a persistent gap between evaluation impact and detector sensitivity. In particular, at 1.4B parameters, training on four verbatim copies of BBH improves benchmark accuracy by 8.6 points across two seeds, while the strongest evaluated likelihood-based detector achieves only 0.39 per-item detection power. We further show that this silent region persists under isolated-dose validation and separate benchmark-specific memorization effects from broader answer-format transfer.

Our findings demonstrate that contamination audits should report calibrated sensitivity rather than only negative findings. CONTAM-LADDER provides a reproducible framework for measuring what contamination detectors can and cannot rule out.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
5 Sep 2026ICLR 2027 (under review)submittedICLR 2027Desk rejectedreviews ↓[1]PDF[1]
Missing a version?

ICLR 2027

Desk rejected · OpenReview

Updated 24 Nov 2026, 17:04 UTC.

The venue hasn't published any reviews yet.

Missing a submission?

Loading the discussion…