Plug-in Image Quality Control for Few-Step Posterior Diffusion Super-Resolution
Anonymous authors
ICLR 2027
TL;DR. numerical method; error estimation; super resolution; diffusion model
Abstract. Diffusion-based super-resolution (SR) has made remarkable progress, mainly through diffusion-prior approaches that rely on assumed degradation likelihoods or generative priors. Posterior diffusion SR instead learns directly from LR--HR pairs, but plug-in mechanisms for controlling the image quality of pretrained models remain less explored. To the best of our knowledge, we propose the first plug-in module for few-step posterior diffusion SR that enables image quality control without retraining the core model. Motivated by high-order diffusion solvers, we formulate a derivative-based correction targeting the per-step posterior-mean discrepancy, which may include the effects of accumulated discretization error. This discrepancy is related to a covariance-weighted KL gradient, motivating an LR-based image-guidance surrogate whose effective scale is calibrated for each denoising step. The sign of the guidance selects between a fidelity-oriented mode and a sharpness-oriented mode. In blind SR, the fidelity-oriented mode improves fidelity metrics, while the sharpness-oriented mode achieves higher scores on non-reference perceptual metrics such as MANIQA and CLIPIQA surpassing Stable Diffusion-based methods on RealSR. Our module provides continuous access to a range of image-quality operating points within a single pretrained posterior model.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
ICLR 2027
Under review · 3 reviews · OpenReview
Updated 25 Nov 2026, 10:35 UTC.
- Rating
- 2/4
- Confidence
- 3/4
- Soundness
- 2/3
- Presentation
- 2/3
- Informativeness
- 2/3
Read review
Summary
For few-step posterior diffusion SR, a plug-in guidance method that does not require retraining the backbone is proposed. The stepwise guidance scale is obtained through LR–HR calibration, and the positive and negative directions of the guidance are used to switch between fidelity-oriented and sharpness-oriented operating points.
Strengths
The paper introduces a practically appealing plug-in mechanism that turns pretrained few-step posterior diffusion SR models into controllable systems without retraining the backbone. The solver-inspired perspective is interesting, and the experiments on ResShift and UPSR show a consistent ability to move between fidelity-oriented and sharpness-oriented operating points.
Weaknesses
The central theoretical narrative is stronger than what is ultimately justified by the inference-time algorithm: the LR-based surrogate is calibrated only in magnitude and is not shown to align directionally with the oracle correction, while the derivation also relies on a nontrivial Jacobian approximation. Moreover, the claimed continuous operating range and upper/lower bounds are insufficiently validated because the quantitative evaluation focuses mainly on two endpoint settings rather than dense control sweeps.
Questions for the authors
-
The connection between the proposed guidance and a genuine second-order discretization correction is not sufficiently established. The paper itself acknowledges that \delta_t mixes prediction error, conditional uncertainty, and accumulated discretization error, while Eq. (5) additionally relies on the strong approximation J_t\approx-a_tI. Please empirically quantify the Jacobian residual and clarify which claims are exact, approximate, or purely motivational.
-
Eq. (13) calibrates only the magnitude of the LR-based gradient against the oracle discrepancy, but does not ensure directional alignment between them. Since the effectiveness of a mean-shift correction critically depends on direction, this is a missing validation. Please report per-timestep cosine similarity between the proposed LR guidance and the oracle correction, together with its variance across images and datasets.
-
Continuous-control claim. Continuous image-quality control is presented as a main contribution, yet Table 2 primarily reports the two endpoint settings LR+ and LR−. Please provide dense sweeps over s in [-1,1] and plot fidelity/perceptual metrics against s for both backbones and datasets.
-
The manuscript refers to LR+ and LR− as upper and lower bounds of attainable image quality, but the current analysis does not establish that these endpoints are extrema for the reported metrics. Different metrics may be non-monotonic with respect to the guidance strength, especially under sharpening artifacts. I suggest either providing empirical/theoretical justification for the bound interpretation or using a more conservative term such as “operating endpoints.”
-
The experiments use ResShift and UPSR, but these models share closely related posterior/residual-shifting formulations, so the evidence for generality is limited. And the sharpness-oriented mode is mainly supported by MANIQA and CLIPIQA, a broader set of perceptual metrics would substantially strengthen this claim.
1 comment
- Rating
- 2/4
- Confidence
- 2/4
- Soundness
- 2/3
- Presentation
- 2/3
- Informativeness
- 2/3
Read review
Summary
This paper proposes a training-free inference-time guidance module for few-step posterior diffusion models for image super-resolution. The method uses an LR-based surrogate for a theoretically motivated KL-gradient correction and calibrates its scale at each diffusion step. By changing the sign of the guidance, the method aims to control the fidelity–perceptual quality trade-off without modifying the pretrained model. Experiments on ResShift and UPSR report improvements in distortion metrics under fidelity-oriented guidance and no-reference perceptual metrics under sharpness-oriented guidance.
Strengths
-
Practical control: The proposed method addresses a relevant practical problem: adjusting the fidelity–perception trade-off (long standing problem in the SR community) of pretrained few-step diffusion models without retraining. Because the correction requires only a simple modification of the reverse mean, it introduces negligible additional inference cost.
-
Evaluation: The paper evaluates both directions of the proposed guidance rather than reporting improvements at only one operating point. This is useful because image SR inherently involves a trade-off between reconstruction fidelity and perceptual quality. The discussion of NIQE and other potentially conflicting perceptual metrics also demonstrates awareness of the limitations of current evaluation protocols.
Weaknesses
-
Insufficient justification for the Jacobian approximation: Proposition C.1 assumes that the denoiser Jacobian satisfies , implying a negative-definite Jacobian. However, for a Bayes-optimal -predictor under the assumed Gaussian forward process, the Jacobian is proportional to the conditional covariance, which is positive semidefinite, raising concerns about the validity of the proposed approximation.
-
Independence: The inference-time method replaces the oracle gradient with , which is independent of the denoiser Jacobian. This makes the connection between Proposition C.1 and the actual guidance mechanism unclear. The authors should empirically examine the Jacobian's sign and spectrum, as well as the approximation residual , to better justify the theoretical formulation.
-
Unclear whether fidelity improvements: Although LR+ improves several full-reference metrics, the results suggest that these gains may primarily come from suppressing high-frequency details rather than correcting reconstruction errors. For example, on RealSR, UPSR with LR+ achieves a MANIQA nearly identical to Bicubic's, while its CLIPIQA score also shifts toward the Bicubic baseline. Moreover, LR+ consistently degrades FID for both UPSR and ResShift on RealSR.
-
Continuous control: Although the method introduces a continuous guidance parameter , the main quantitative evaluations report only the two endpoints, . Without metric-versus- curves, it is difficult to verify whether the method provides smooth, monotonic, and stable control over the fidelity–perception trade-off.
Questions for the authors
-
Can the authors empirically evaluate the Jacobian approximation, including its spectrum and the relative magnitude of the residual?
-
How sensitive are the coefficients to the dataset? (e.g., scale)
-
Can the authors provide human preference evaluations or more robust perceptual comparisons (e.g, MOS)?
1 comment
We thank the reviewer for the constructive review. We apologize for the late response, which leaves little time for discussion. We rewrote the theory: Proposition C.1 is replaced by Sec. 3.3 and App. D.7. All references are to the revised PDF.
W1 / Q1. Jacobian sign, spectrum, and residual.
- The approximation is now with (Eqs. 105–106). The negative slope comes only from the explicit minus sign. As the reviewer notes, this is consistent with the Jacobian of the Bayes-optimal predictor, which is proportional to the conditional covariance. It is exact for the Gaussian predictor (Eq. 107).
- Table 21 reports the band-wise slopes , which are Rayleigh quotients of the Jacobian on the low/mid/high bands.
- Sign: all band-wise slopes are positive.
- Spectrum: they differ by at most 1.8× across bands.
- Residual: , i.e., 2–65% of the target energy from the second step on, and about 90% at the first step.
- These quantities are measured on the noise-matched displacement, which separates the noise carried by (App. D.7, ¶"Noise-matched HR reference").
W2. Independence of the inference direction from the Jacobian.
- The Jacobian enters only through the per-step scalar , and the calibrated estimates it (Eq. 13 vs. Eq. 106). For this reason the inference direction needs no Jacobian.
- Eq. 6 is an identity relating the LR-based and HR-reference directions, with an HR fitting residual and a reference term. A per-step rescaling is absorbed by the slope (Eq. 115).
- Empirically, the per-step error decreases at most steps under +1× and increases under −1× (Tables 10–12).
- Direct measurement (Table 20, 50 calibration tiles). Except at the three steps with the smallest effective coefficients, the cosine between and the applied LR correction is positive for at least 92% of the images, with means of 0.20–0.31 (UPSR) and 0.19–0.61 (ResShift). The LR direction thus points toward the target without any Jacobian and covers part of it: the attainable per-step reduction is 2–6% for UPSR and up to 22% for ResShift.
W3. LR⁺ fidelity vs. high-frequency suppression.
- We partly agree. LR⁺ is the fidelity end of the trade-off and suppresses high-frequency content (Fig. 10). FID increases in most settings, which we now state in Sec. 4.
- LR⁺ is not equivalent to low-pass filtering. At comparable PSNR, Gaussian smoothing raises NIQE to 8.0–8.5 and lowers CLIPIQA to 0.29–0.32, whereas LR⁺ keeps them at 6.3–6.4 and 0.32–0.39 (Tables 3–4). The per-step error toward the HR reference also decreases (Tables 10–12).
W4. Continuous control.
- Table 4 (UPSR) evaluates nine values of in steps of 0.25, extended to ±3×; Tables 5–6 (ResShift) use steps of 0.5. The multiplier in these tables equals for .
- Within this range, PSNR and MANIQA change monotonically for UPSR and 4-step ResShift (Tables 4–5). CLIPIQA does too, except for a small dip at for UPSR. LPIPS has an interior optimum near , and NIQE is not monotonic.
- Beyond the calibrated scale, outputs over-smooth or over-sharpen (Fig. 10).
Q2. Sensitivity to the dataset.
- Fig. 5 compares image-specific with dataset-level calibration.
- Table 21 gives the image-to-image variation of the slope (CV 0.02–0.45 across steps).
- Tables 4–6 show that the metrics change smoothly with a global multiplier around 1×.
Q3. Human evaluation. We agree that no-reference metrics are imperfect proxies, which is why we report where they disagree (NIQE vs. MANIQA/CLIPIQA). A controlled MOS study requires a sufficient number of raters and a controlled protocol, which we could not arrange within the rebuttal period. As more robust perceptual comparisons, we add MUSIQ, TOPIQ, and LIQE (Tables 13–16) to LPIPS and DISTS, and the trends of the two modes agree across them. These metrics can score sharpened outputs above the HR reference (Tables 13, 16), so we present them as descriptors of operating points rather than as a ranking of perceived quality.
- Rating
- 2/4(+1)
- Confidence
- 4/4
- Soundness
- 1/3
- Presentation
- 1/3
- Informativeness
- 2/3
Read review
Summary
This paper proposes a plug-in quality-control method for few-step posterior diffusion super-resolution. It calibrates per-step guidance scales using paired LR–HR data and uses only LR conditioning at inference, controlling fidelity and sharpness through the sign of the guidance. Experiments show that the method can adjust the image-quality trade-offs of ResShift and UPSR, but its connection to second-order discretization-error correction has not been adequately established.
Strengths
- The method allows output quality to be adjusted without retraining the backbone, offering practical value.
- The main trends are consistent across two backbones and two datasets: LR⁺ improves full-reference metrics, while LR⁻ improves some no-reference metrics and FID.
- The authors demonstrate artifacts caused by excessive guidance and discuss disagreements among evaluation metrics.
Weaknesses
-
The main text claims formal equivalence to second-order error correction, but the appendix explicitly acknowledges that no convergence-order guarantee is established. It also does not establish equivalence between the auxiliary KL gradient and the reverse-kernel KL gradient. The HR-referenced mean discrepancy includes prediction error and conditional uncertainty and therefore cannot be directly identified with discretization error.
-
Equation (74) approximates the Jacobian by a negative scalar multiple of the identity matrix, whereas the ideal MSE predictor under Equation (27) has a positive semidefinite Jacobian. Although the actual network need not satisfy this ideal property, the authors neither explain why the approximation is reasonable nor assess the magnitude of the neglected residual.
-
Equation (13) matches to , whereas the actual displacement in Equation (14) involves . The paper does not sufficiently explain how the covariance enters calibration or under what conditions it can cancel out or be absorbed into the scale.
-
The experiments do not isolate the contributions of per-step calibration, the calibration criterion, and guidance during sampling. In particular, comparisons with a shared guidance scale, standard parameter search, and properly tuned smoothing/sharpening baselines are missing. Consequently, it remains unclear whether the gains primarily arise from simple residual processing.
-
The main text lacks a workflow diagram that clearly distinguishes offline calibration from online inference, as well as the HR-reference gradient used in the theoretical analysis from the LR-based auxiliary gradient used in practice. This makes the method difficult to follow.
Questions for the authors
Please refer to the weaknesses above.
1 comment
We thank the reviewer for the careful review. We agree with the main concern that the connection to second-order discretization-error correction was overstated. We rewrote Section 3.3 and Appendix D, and revised the corresponding statements in the Introduction, Experiments, and Conclusion. Every claim is now either an exact identity or a stated approximation whose error we measure. All references are to the revised PDF.
W1. Equivalence claim; auxiliary vs. reverse-kernel gradient; discrepancy vs. discretization error. We agree on all three points.
- We removed the equivalence claim. App. D.1 now serves only as motivation.
- What remains is a qualified link. The target contains the Euler local error (Eq. 104), and its share grows with the step size (ratio after Eq. 108). Consistently, the correction acts more strongly with coarser steps: under +1×, the per-step error falls by up to 10.5% for 4-step ResShift vs. at most 3.7% at the last 13 steps of 15-step ResShift (Tables 10–11), and the HR oracle raises PSNR by 2.42 dB vs. 1.40 dB (Tables 5–6).
- The target is the preconditioned mean gradient of the reverse-kernel KL (Eq. 4; App. D.7, Eq. 103). It splits into the Euler local error and a modular component (Eq. 104), so we no longer identify it with discretization error (Sec. 3.3, ¶"Posterior-mean discrepancy").
- The two gradients are linked by (Eq. 105). The only approximation is (Eq. 106).
W2. Jacobian sign and residual.
- The approximation is now with . The slope is negative only because of the minus sign in Eq. 105. This is consistent with the positive semidefinite Jacobian of the ideal predictor, and the approximation is exact for the Gaussian predictor (Eq. 107).
- App. D.7, ¶"Where the uncertainty weighting enters", states when a scalar is justified.
- Table 21 measures the residual. From the second step on, the scalar explains 35–98% of the target energy, and the band-wise slopes differ by at most 1.8×. At the first step it explains about 10%; the slope keeps the correct sign there, and the applied LR correction is positively aligned for all images (Table 20), so by the partial-correction bound in App. D.7 the correction there is weak rather than harmful.
W3. Covariance in calibration. Eq. 13 now fits the same vector that is applied at inference (Eq. 14). The conditions under which the covariance cancels are given in Sec. 3.3 (¶"LR-based image guidance", last paragraph), App. D.2 (Eqs. 49–50), and App. D.7. For ResShift, any isotropic cancels; for UPSR, cancellation requires .
W4. Ablations and simple residual processing.
- Smoothing and unsharp masking are compared in Tables 3 and 15 and Fig. 11. At comparable PSNR, smoothing raises NIQE to 8.0–8.5, whereas LR⁺ keeps it at 6.3–6.4 (Sec. 4, ¶"Quantitative analysis").
- Sensitivity to the scale is shown in Tables 4–6 and Fig. 10, and image-specific vs. dataset-level calibration in Fig. 5. Fig. 9 shows that changing the per-step combination of scales (sign, magnitude, and ratio across steps) produces distinct artifacts. The calibration data are described in Sec. 4, ¶"Testing environment".
- Per-step vs. shared scale.
- The calibrated coefficients differ across steps more than across images. The effective per-step coefficients span 6.0–54.7 (9.1×) for UPSR and 5.1–69.8 (14×) for 15-step ResShift, excluding the two steps whose coefficients are near zero (Table 8). Across images, the per-image optimal slope varies with a coefficient of variation of at most 0.45 (Table 21), and the applied scale lies inside the factor-2 band below for 76–100% of the images at all but the three steps with the smallest coefficients (Table 20).
- By the partial-correction bound (App. D.7), a scale above a step's optimum increases that step's error, and a scale far below it removes little.
- With a 9.1× spread, any coefficient shared across the UPSR steps either exceeds twice the optimum at , producing artifacts, or stays below 23% of the optimum at and , recovering at most 40% of the attainable reduction there. Sharing across images costs far less, which is why we calibrate per step and share across images.
- Table 19 (UPSR) tests this directly. It fixes at every step to its first-step value 53.3, which is 8.9× the optimum at .
- At , PSNR is unchanged (29.06 vs. 29.09), but LPIPS worsens by 14% (0.230 → 0.262), and DISTS and NIQE worsen as well.
- At , PSNR drops by 2.2 dB, NIQE rises from 6.52 to 8.60, and FID rises from 130.0 to 159.6.
W5. Workflow.
- Fig. 1 (Sec. 3.3) block diagram is revised.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the reviewer for the constructive review. We apologize for the late response, which leaves little time for discussion.
Q1. Second-order connection; what is exact, approximate, or motivational. We no longer claim that the correction is equivalent to a second-order discretization correction. We claim that it targets a discrepancy that contains the discretization error, as summarized below.
Exact:
Approximate, measured:
Motivational:
What remains of the discretization link.
Jacobian sign. The approximation is now Jˉt≈ctI with ct>0. The negative slope comes only from the minus sign in Eq. 105, and the approximation is exact for the Gaussian predictor (Eq. 107).
Jacobian residual (Table 21). From the second step on, one scalar explains 35–98% of the target energy, and the band-wise slopes are positive and within 1.8× of each other. At the first step it explains about 10%; the correction there is weak but keeps the correct sign, and the applied LR correction is positively aligned for all images (Table 20).
Q2. Magnitude-only calibration and directional alignment.
Q3. Dense sweeps over s.
Q4. "Upper and lower bounds." We agree and adopted the reviewer's term. Sec. 4 (¶"Operating range") now calls LR⁺ and LR⁻ operating endpoints, and the Conclusion describes the calibrated scale as a practical end point of the control range. Tables 4–6 confirm that they are not extrema: larger scales move some metrics further, for example CLIPIQA 0.539 at 3× vs. 0.492 at 1× for UPSR, at the cost of artifacts (Fig. 10).
Q5. Generality and perceptual metrics.